IRIS Touch 200 User's Manual
Contents
1. Perser agseseesese 21211211212112122122 13 200 Range Dialer Installation Manual Version 1 0 pr ae Now certified iant with EN50136 The information contained is supplied without liability for any errors or omissions No part may be reproduced or used except as authorised by contract or other written permission The copyright and foregoing restriction on reproduction and use extend to all media in which the information may be embedded 2008 Chiron Technology Ltd Contents Me Modic WOM EODD OTT 1 1 1 About THAIS BUA 5 iei iesetce beet irita e tapias epus pecora nea pismen 1 IEEE OIM EO OLET DLL 1 1 9 System specificaliofis niet cr eene rnc R e innen 2 2 Beroe VOU SURE siete tiet uites ubt pete tet Erea Ap iaa a saps S EEES 3 20 PACKAGE ICOM IES tessa ite cti hari ice iere a eu xn rad Re inr 3 2 2 JABissegilsites xxu egere Red 3 3 Alarm dialer interface nete ce oec eese cet a Ee ve ER EET 4 A Installing the IRIS TouchiBlalet terere pe eere bana ees 4 b Configuring the IRIS Teu ch Dialer 1 22 pii sicci eco istaec binder erat 7 6 JPasstinstelletiol ccce ces coin ea r sa E0600 LL Rc Paca saa Dez bc Esa de sne HELM a Ho E ca ET 8 Te s E E TL a eee ere eee TEQUE 8 Jd doetellatiGf cuneo TE E TEE 9 7 2 Default alarm MESSAGES susmusnssssrenreserenrsenrn ennen annen renen reor rn r rn rr non enn o en 10 9 ROL CUNO UNG 22 2220 5r4 crecattcataceticatantttac
2. 22 If the Monitoring Centre requires a backup IP address to be entered this is done in the same way 2 If alarm signalling over GSM is required add a leading digit 7 to the normal PSTN telephone number of the Monitoring Centre 3 Ifthe panel is required to make outgoing calls over IP for upload download or remote configuration then where the telephone number for this would normally be entered put in the digit 8 followed by the destination IP address in 12 digit format as above 4 Installing the IRIS Touch Dialer Use the following procedure to install the IRIS Touch Dialer Note For installations using PIN alarm inputs see the P N alarms section for additional information and for wiring to relay outputs see the Relay outputs section e Do not apply power to the dialer until indicated 4 Iris Touch 200 Range Dialer Installation Manual touch Decide where to run the cables Decide the best way to run the cables to the PCB This can be either Behind the unit through the wall e Through the bottom of the back plate of the unit via the knock outs Disassemble the unit Remove the two case fixing screws 1 and open the unit 2 Remove the two PCB fixing screws 3 and remove the PCB Mount the unit on the wall Position the back plate on the wall drill 3 holes put the cables through the opening at the base of the plate 4 or via the knockouts 5 and secure the plate to the wall with the 3 scr
3. by incoming SMS messages Selects how local communications problems are reported via Relay outputs SMS Sets the text string that appears on screen to advise the user what action to take e g support centre telephone number Sets IP address of support centre for remote diagnostics Selects language Sets a password to the Installer menus if required Sets display contrast Clears tamper alarm if tamper switches have been triggered The dialer has a diagnostic tool with integral speaker to allow the audio signal to and from the alarm dialer to be heard The audio can be switched on and off Sets all settings back to factory defaults Iris Touch 200 Range Dialer Installation Manual 11 touch Appendix B Installation photos 1 12 Iris Touch 200 Range Dialer Installation Manual 14 11 12 ns 10 171 18 16 Iris Touch 200 Range Dialer Installation Manual 13 touch Appendix C Specification Alarm Dialer Interface Two wire interface via RJ11 socket 40V feed at 12mA Ringing voltage 40V P P to REN4 for incoming calls Off hook detection with dial tone presented to alarm dialer DTMF tone recognition for dialing outgoing calls and alarm signaling Ethernet Interface 10Mbps and 100Mbps 10 100BaseT with auto negotiation UTP with standard RJ45 socket for CAT 5 cabling Dynamic IP addressing DHCP or fixed GSM GPRS Interface Dual band GSM 900 MHz and DCS 1800 MHz MMCX socket for antenna co
4. ceed through the configuration Note To select an option on the screen touch the screen display Use the following procedure to configure the IRIS Touch Dialer 1 Plug the power cable into the battery backed supply of the alarm panel The cable with the white stripe is the ve connection Ensure that the display on the dialer becomes active The dialer carries out a self test and the Welcome screen then displays Note If the power has been connected for the first time the Language menu displays Select the appropriate language from the list of languages available 2 Select the Installer Menu option from the Welcome screen Select the Installation Wizard option from the Installation Menu f 4 Follow the remaining instructions on the screen to complete the configuration Once the installation is completed successfully the message Status System OK is displayed on the Welcome screen and the LED Indicator on the top of the unit 17 is on steady 5 Carry out all the standard alarm signaling tests appropriate for the alarm System 6 Push up the slider to cover the touch screen Iris Touch 200 Range Dialer Installation Manual 7 touch 6 Post installation Once you have completed the installation you must 7 Ensure the system is running correctly the LED light on top of the unit is on steady and alarms are being signaled to the Monitoring Centre correctly After a short period of inactivity the display w
5. cure alarm transmission over GPRS Configuration and diagnostics over GPRS Alarm transmission over GSM Touch 200 GSM Y Y EN Iris Touch 200 Range Dialer Installation Manual Touch 220 Ethernet Y Y SS SS A E Touch 240 Ethernet amp GPRS Y Y Y SS SS A ES 2 2 1 touch Before you start Package contents In this package you should have the following components 2 2 Main dialer unit comprising e PCB with 3 part plastic enclosure back front and slider e 4x assembly screws e 2x tamper switch springs Power cable black for connection to DC supply Ethernet cable cream for connection to IP network Ethernet Ethernet amp GPRS only Antenna for GSM GPRS GSM Ethernet amp GPRS only Dialer cable grey for connection to dialer output of alarm panel Screws and plugs 3 of each for wall mounting Sense resistor 18K ohm for alarm dialer cable fault tamper detection Installation manual Pre requisites For installations using IP Ethernet or GPRS you must ensure you have the following The IP address for the Monitoring Centre Confirmation that the Monitoring Centre is set up and ready for the account number or name to be used for this IRIS dialer The type of IP address either automatic or fixed for the installation site If the site has a fixed IP address you should get this information from the customer in advance together with the Gateway Ad
6. dress and the Subnet Mask for the IRIS dialer An additional long Ethernet cable in case the installation site requires one longer than that supplied with the IRIS dialer A SIM card enabled for GPRS with the PIN code clear Ethernet amp GPRS only The GPRS Access Point Name APN of the SIM card provider Some networks also require a User Name and Password which can also be obtained from the SIM card provider Ethernet amp GPRS only Iris Touch 200 Range Dialer Installation Manual 3 touch 3 Alarm dialer interface IRIS dialers carry alarm signals from the alarm panel over IP completely transparently so when they arrive at the Monitoring Centre it is as though they had come over a traditional PSTN connection IRIS dialers support SIA Levels 1 to 3 Contact ID Scancom Fast Format and Robofon protocols one of which virtually all alarm panels will support Apart from the following no reconfiguration of the alarm panel is required for use with IRIS dialers 1 If alarm signalling over Ethernet or GPRS is required change the setting in the alarm panel for the telephone number to be dialled for alarm signalling This number should be changed to the IP address of the Monitoring Centre entered as 12 digits Each of the four IP address numbers separated by a should be entered as a 3 digit number with leading 0 s as required and the s should be excluded For example IP address 10 1 146 22 is entered as 0100011460
7. ems Intrusion and hold up systems Part 1 System Requirements dated Feb 2004 and EN50136 1 1 Alarm Systems Alarm transmission systems and equipment January 1998 with Amendment 1 August 2001 as follows e The IRIS dialers conform to Environmental Class ll e The IRIS dialers are compliant to ATS 6 compatible with Security Grade 4 Safety Care should be taken when interconnecting telecommunications equipment that only like interfaces are interconnected to avoid safety hazards SELV SELV Safety Extra Low Voltage is defined as a secondary circuit which is so designed and protected that under normal and single fault conditions the voltage between any two accessible parts does not exceed a safe value 42 4V peak or 60V dc maximum The interfaces on the IRIS dialer have the following safety classifications e Dialer Interface SELV suitable for connection to the TNV interface of a single line telecommunications equipment such as telephones faxes etc e Data Interface SELV suitable for connection to the SELV interface on a data terminal such as a PC COM port Power Interface SELV for connection to a DC supply nputs and Outputs SELV for connection to alarm output and input pins Iris Touch 200 Range Dialer Installation Manual 15
8. etected and the Monitoring Centre alerted In this case the connections should be made as shown below Reference ground Pin inputs 4K7 Resistor 15K Resistor Note For this feature to work correctly it is essential that the resistors are connected at the contact end of the loop and not the dialer end The Monitoring Centre must also enable this facility on the dialer Iris Touch 200 Range Dialer Installation Manual 9 touch 7 2 Default alarm messages The default SIA messages for each PIN are shown below Pin Set message Restore message Meaning 1 NBAO1 NBRO1 Burglary alarm restore 2 NFA02 NFRO2 Fire alarm restore 3 NQA03 NQRO03 Emergency alarm restore 4 NOP04 NCLO4 Open close 8 Relay outputs The IRIS dialer has two relay outputs 20 that can be used in a number of ways e To indicate communications path failure e Activation by incoming SMS Message e Setting by the Monitoring Centre The relay contacts are normally open and closed when activated Wire to these contacts as required and define how they are to be used using the configuration options on the Settings Menu See Appendix A for more details 9 Troubleshooting Problem Resolution No screen display when IRIS Check that there is power to the system dialer is connected to the and that the wiring is the correct polarity power A fault develops and is Touch the display and the instructions will indicated by the LED on the top guide you t
9. ews supplied 6 Plug in the connectors Connect the relevant cables to the PCB Ethernet cable cream 7 Ethernet Ethernet amp GPRS only Dialer cable grey 8 e Power cable black 9 Install the antenna GSM Ethernet only Position the antenna in the groove in the back plate of the unit 10 and connect the antenna to the PCB 11 Note Alternatively you can use an external antenna if the location of the internal antenna does not give sufficient signal Fit the tamper switch springs The IRIS dialer is protected against tampering e g removal from the wall or opening of the case by two tamper switches 12 one either side of the PCB These switches are held by springs that press against the wall and the top cover Before fitting the PCB make sure the springs that come with the unit are fitted correctly to the tamper switches Iris Touch 200 Range Dialer Installation Manual 5 touch 10 11 6 Fit the PCB to the back plate Fit the PCB to the back plate aligning the corners of the plate with the edgings on the back plate and the two bottom screw fittings 13 Screw in the 2 top screws only 14 Fit the SIM card GSM Ethernet amp GPRS only Fit the SIM card 15 Power must not be applied to the PCB while the SIM card is being fitted or removed or it may be damaged Plug in the external cables e Plug the dialer cable into the alarm panel dialer If the alarm panel has scre
10. hrough identification of the of the unit flashing problem Go to the Installers menu and select Test to use the integrated test function 10 Iris Touch 200 Range Dialer Installation Manual touch Appendix A Settings menu Setting Network Interfaces Account Number Name Monitoring Centre IP Address Dialer IP Address GPRS Settings Alarm Panel Interface Pin Inputs Relay Outputs Trouble Reporting Language Installer Password Contrast Tamper restore Audio Default all Purpose Selects which network interfaces are going to be used i e Ethernet and or Ethernet GPRS Stops dialer reporting trouble on interfaces not being used The IRIS account number name as allocated by the Monitoring Centre IP address of the receiver at the Monitoring Centre IP address of the dialer i e either automatic DHCP or fixed GPRS Access Point Name APN user name and password View signal strength Selects whether or not the 2 wire cable to the dialer is monitored for short and open circuit Note For monitoring to function correctly a sense resistor must be fitted as described earlier in this manual Selects whether or not pin input is monitored using sense resistors and selects input function Send SMS message SendSIA format alarm over IP trouble and restore event codes and zone number Send Fast Format alarm over IP alarm or open close and set pin polarity Activation of relay outputs
11. ill switch off To switch it back on touch the display anywhere If a fault should develop then the LED light on the top of the unit will start flashing and the display will show a system fault message This message can be touched to gain access to more information Ensure the user is aware of this and what action they need to take should a fault occur PIN alarms The IRIS Touch series have PIN inputs 18 that can be used to generate alarm messages These can be Text messages via SMS GSM Ethernet amp GPRS only SIA alarm messages over IP to the Monitoring Centre Ethernet Ethernet amp GPRS only Fast Format alarm messages over IP to the Monitoring Centre Ethernet Ethernet amp GPRS only The messages for each PIN can be configured via the Settings Menu on the touch screen display See Appendix A for more details 8 Iris Touch 200 Range Dialer Installation Manual touch 7 1 Installation Each PIN input is designed to be connected in a loop via an open close contact source from an alarm panel or other device to a reference ground PIN 19 available on the IRIS dialer as shown below Reference ground Pin inputs 1 4 TR ree Opening the contact i e loop is open circuit generates an alarm signal Closing the contact generates the equivalent restore signal It is also possible to link the contacts to the IRIS dialer via sense resistors so that an open or short circuit tamper on the loop can be d
12. nnection IP TCP ports outbound 51292 diagnostics 52737 polling 53165 alarms UDP ports for upload download 8738 and 8739 PIN Inputs Maximum input voltage range OV to 24V Input low threshold lt 2V Input high threshold gt 3V Input pull up impedance Internal 10K to 5V supply Relay Outputs Maximum operating voltage 24V Maximum current rating 1A Power Supply Supply voltage 9 30V DC Ethernet only typical current dialer on hook 145mA supply at 12v Ethernet only typical current dialer off hook 175mA supply ay 12V With GSM GPRS typical current dialer on hook 185mA supply at 12V With GSM GPRS typical current dialer off hook 215mA supply at 12V Note These figures are based upon the Ethernet link being connected With GSM GPRS there will also be additional transient peak current of up to 250mA required as GSM and GPRS transmissions e g for network registration and calls are made Weights Dialer unit 300g Fully packaged 500g 14 Iris Touch 200 Range Dialer Installation Manual touch Conformance The IRIS range of alarm dialers comply with the following European Directives e 1999 5 EC Radio amp Telecoms Terminal Equipment Directive e 72 23IEEC Low Voltage Directive e 89 336 EEC Electromagnetic Compatibility Directive as amended by 92 31 EEC Conformance to EN50131 and EN50136 The IRIS dialers are compatible with the requirements of European standards prEN50131 1 Alarm Syst
13. o distant future PSTN lines may be withdrawn The IRIS dialer range is unique in offering a quick and cost effective way to interface any existing alarm system to alternative networks such as GSM Ethernet and GPRS As a result of the flexibility and power of IRIS it has become the IP transmission system of choice for Monitoring Centres across Europe The IRIS 200 series is intended to be used with alarm panels that do not have sufficient space inside their enclosures for an IRIS dialer There are three dialers in the range e RIS Touch 200 GSM e RIS Touch 220 Ethernet RIS Touch 240 Ethernet amp GPRS The IRIS Touch dialer should be located next to the alarm panel and powered from the panel s internal battery backed DC supply Iris Touch 200 Range Dialer Installation Manual 1 touch 1 2 3 System specifications Feature Stylish tamper proof enclosure Easy to install and test with touch screen interface 2 wire POTS analogue interface to standard alarm dialers Support for SIA 1 3 Contact ID Scancom Fast Format and Robofon protocols Pin inputs for alarm messages over SMS Relay contact outputs 9 30V DC power from alarm panel USB port for local configuration Secure polling monitoring over Ethernet Secure alarm transmission over Ethernet Pin inputs for alarm messages over Ethernet or GPRS Configuration and diagnostics over Ethernet Secure polling monitoring over GPRS Se
14. tachiecatacesissaacasigeiaa eseuacssasetaateaseisestesstan 10 9i Jroubleshoofling cad ede a ee dh Sada E 10 Appendix A Settings MCENU ssessesresrserrenrsenrenrreor ennen reor rn ren r rr rna r enn renen rr nro nn nn 11 Appendix B Installation PWOtOS 2 trt e re rette raten terere tr trece 12 Appendix C Specification oec rer Eti teen oe terere ea ties 14 Iris Touch 200 Range Dialer Installation Manual ii Iris Touch 200 Range Dialer Installation Manual Tris touch 1 Introduction 1 1 About this manual This manual is designed to help you the Installer with the installation process for the IRIS Touch alarm dialer We recommend that you read through this manual in its entirety before you visit the customer s site and begin the installation 1 2 Overview The IRIS range of alarm dialers allow users to migrate intruder alarm systems away from traditional PSTN communications to IP based and or wireless networks without the need to upgrade or replace the alarm system The majority of intruder alarm systems which are configured to make alarm calls to a central monitoring station use the traditional PSTN analogue network as the communications path However PSTN is becoming increasingly unsuitable as users move to IP and Voice over IP VoIP for their fixed networks or rely purely on mobile GSM and GPRS communications In addition most PSTN service providers are migrating to VoIP networks so in the not to
15. w connections cut the connector off the cable and strip the cable using the 2 inner wires Polarity is not important Plug the Ethernet cable into the local IP router or socket that has been allocated for the IP connection Plug in the sense resistors Fit the 18K sense resistor in parallel with the dialer output of the alarm panel at the alarm panel end of the cable Note This resistor enables the IRIS dialer to detect cable faults and or tampers and must be fitted at the alarm panel end of the cable to function correctly Fit the front cover Slot the top of the front cover into the top of the back plate and click the bottom of the front cover to the bottom of the back plate Fix in place with the 2 screws provided 16 Pull down the slider to reveal the touch screen Iris Touch 200 Range Dialer Installation Manual touch 5 Configuring the IRIS Touch Dialer The majority of configurations can be carried out via the touch screen interface display on the IRIS dialer For more complex systems for example where the data port is used additional configuration is available via the USB connector using a laptop PC and IRIS dialer configuration software available via the Chiron website The touch screen display on the IRIS dialer provides an Installation Wizard which guides you through a set of instructions for configuring the dialer It is recommended that you use this Wizard as it automatically carries out tests as you pro