1. appearance are subject to change without notice for purposes of improvement NOTE Nebulization rate and particle size are dependent on the characteristics of the nebulizer chosen Part No 1160837 13 Invacare Pediatric Bear SUPPLEMENTAL INFORMATION SUPPLEMENTAL INFORMATION Compressor If the unit shuts down frequently you may have a low voltage situation Low voltage can also be suspected when The motor does not get up to full power or speed e Home fuses or circuit breakers activate when starting compressor e Lights dim or remain dim when compressor is started Other motor operated appliances fail to operate properly or too many motor operated appliances are on same circuit Extension Cords If you must use an extension cord use only a cord having the same or higher electrical rating as the device being connected Make certain the extension cord is in good condition without any exposed wires or hazardous contacts and the extension cord wire is NOT LESS than 18 gauge for 25 feet Invacare Pediatric Bear 14 Part No 1160837 SECTION HANDLING SECTION HANDLING Shipping Instructions The shipping container has been designed to assure protection of this device If this device is to be reshipped by common carrier it should be packed in the same carton Unpacking 1 Check for any obvious damage to the carton or its contents If damage is evident DO NOT use Notify carrier Invacare
2. eons ep Su 25 Storage E EA A 25 Nebulizer Change 26 File r Change un a nan a qa 26 SECTION 5 TROUBLESHOOTING 0000000000000000000 27 LIMITED WARRANTY 000000000000000000000000000000000000 29 REGISTER YOUR PRODUCT The benefits of registering include Safeguarding your investment 2 Ensuring long term maintenance and servicing of your product 3 Receiving updates with product information maintenance tips and industry news Register ONLINE at warranty invacare com Please have your model number and purchase date available to complete your registration Any registration information you submit will only be used by Invacare Corporation and protected as required by applicable laws and regulations Invacare Pediatric Bear 4 Part No 1160837 SPECIAL NOTES SPECIAL NOTES Signal words are used in this manual and apply to hazards or unsafe practices which could result in personal injury or property damage Refer to the table below for definitions of the signal words SIGNAL MEANING WORD Danger indicates an imminently hazardous situation which if DANGER not avoided will result in death or serious injury Warning indicates a potentially hazardous situation which if WARNING not avoided could result in death or serious injury Caution indicates a potentially hazardous situation which if CAUTION
3. failure to adhere to the product instructions nor does it include shipping charges incurred in replacement part installation or repair of any such product Invacare s sole obligation and your exclusive remedy under this warranty shall be limited to such repair and or replacement For warranty service please contact the Invacare service department during normal business hours at the toll free telephone number identified on the back cover of this manual Part No 1160837 29 Invacare Pediatric Bear LIMITED WARRANTY Upon receiving notice of an alleged defect in a product Invacare will issue a serialized return authorization It shall be the responsibility of the purchaser to pack the product s or part s in an appropriate manner to avoid shipping damage and return the product s or part s at the purchaser s expense to either Invacare s plant or service center as specified by Invacare in advance The defective product s or component part s must be returned for warranty inspection using the serial number as identification within 30 days of the return authorization date DO NOT return any product s or part s to our factory or service center without prior consent C O D shipments will be refused please pre pay shipping charges LIMITATIONS AND EXCLUSIONS THE FOREGOING WARRANTY SHALL NOT APPLY TO SERIAL NUMBERED PRODUCTS IF THE SERIAL NUMBER HAS BEEN REMOVED OR DEFACED PRODUCTS SUBJECTED TO NEGLIGENCE ACCIDENT IMPROPER OP
4. not avoided may result in property damage or minor injury or both NOTICE The information contained in this document is subject to change without notice Part No 1160837 5 Invacare Pediatric Bear IMPORTANT SAFEGUARDS IMPORTANT SAFEGUARDS A WARNING IMPORTANT SAFEGUARDS contains important information for the safe operation and use of this product CAUTION Federal law restricts this device to sale or rental by or on the order of a physician or any other practitioner licensed by the law of the State in which he she practices to use or order the use of this device This appliance has a polarized plug one blade is wider than the other As a safety feature this plug will fit in a polarized outlet only one way If the plug does not fit fully in the outlet reverse the plug If it still does not fit contact a qualified electrician Do not attempt to defeat this safety feature A WARNING When using electrical products especially when children are present basic safety precautions should always be followed including the following Invacare Pediatric Bear 6 Part No 1160837 IMPORTANT SAFEGUARDS READ ALL INSTRUCTIONS BEFORE USING A DANGER FIRE RISK DO NOT use this product in an oxygen enriched environment i e oxygen tent Risk of electric shock DO NOT disassemble Refer servicing to qualified service personnel To Reduce the Risk of Electrocution ALWAYS unplug this
5. product IMMEDIATELY after using DO NOT use while bathing DO NOT place or store product where it can fall or be pulled into a tub or sink DO NOT place in or drop into water or other liquid DO NOT reach for a product that has fallen into water Unplug IMMEDIATELY Part No 1160837 7 Invacare Pediatric Bear IMPORTANT SAFEGUARDS A WARNING To Reduce the Risk of Burns Electrocution Fire and Injury to Persons This product should NEVER be left unattended when plugged in Close supervision is necessary when this product is used by on or near children and physically challenged individuals Use this product only for its intended use as described in this manual and only with the prescribed medication Use this product only under physician s direction NEVER operate this product with a damaged cord or plug if it is not working properly if it was dropped or damaged or if it was dropped into water Call qualified service personnel for examination and repair Invacare Pediatric Bear 8 Part No 1160837 IMPORTANT SAFEGUARDS A WARNING Keep the nebulizer tubing cord and unit away from heated or hot surfaces including space heaters electric blankets stoves and similar electrical appliances NEVER drop or insert objects into any opening or hose NEVER use while sleeping or drowsy NEVER block the air openings of the product or place it on a soft surface such as a bed or couch where the air openi
6. 6 Before storing supplies between treatments clean and dry the mask and accessories Invacare Pediatric Bear 20 Part No 1160837 SECTION 3 CLEANING AND DISINFECTING SECTION 3 CLEANING AND DISINFECTING Following the cleaning instructions after each use will prevent any remaining medication in the nebulizer cup from drying and causing the device to nebulize ineffectively It is recommended that the nebulizer mouthpiece and mask be thoroughly rinsed with hot tap water after each use and cleaned with a mild detergent after the last treatment of the day The same pieces MUST also be disinfected daily by soaking in a vinegar water solution or a commercially available disinfectant If your physician or respiratory therapist specifies a different cleaning procedure follow their instructions Cleaning the Outer Case A WARNING Unplug unit before cleaning DO NOT submerge in water to clean Clean outer case with damp cloth Part No 1160837 21 Pediatric Bear SECTION 3 CLEANING AND DISINFECTING A DANGER DO NOT attempt to separate the outer case of this unit Removing the case creates a serious electrical shock hazard All disassembly and maintenance of this unit MUST be done by a qualified technician Cleaning the Nebulizer and Mask A WARNING To prevent possible risk of infection due to contamination follow these instructions e Clean the nebulizer and mask before initial oper
7. ABLE OF CONTENTS REGISTER YOUR PRODUCT 4 SPECIAL NOTES 5 IMPORTANT SAFEGUARDS 6 INTRODUCTION I TYPICAL PRODUCT PARAMETERS 12 SUPPLEMENTAL INFORMATION 14 COMPPESSOM 14 Ext nsion Cords uu um nu a a naa uh ay 14 SECTION I HANDLING l 5 Shipping NStrUCtiOn 15 Unpacking u asas qa anal asua uuu 15 Insp ecti huu s a quam 15 SECTION 2 OPERATING INSTRUCTIONS 16 Setup aan cca 16 Treatment Instructions for Nebulizer 19 Treatment Instructions for Mask 20 SECTION 3 CLEANING AND DISINFECTING 21 Cleaning the Outer Case a 21 Cleaning the Nebulizer and Mask 22 Part No 1160837 3 Invacare Pediatric Bear TABLE OF CONTENTS TABLE OF CONTENTS Cleaning the Compressor ssssssssssssssssssessscssssssssssssesssssseseessssees 24 Cleaning the Mouthpiece 24 SECTION 4 MAINTENANCE 25 cs soca ts sect sowie
8. ANCE Nebulizer Change The nebulizer is designed for single patient use The nebulizer MUST be replaced after a long period of inactivity or when it is obstructed by dry medication dust etc Reusable nebulizers should last from six months to one year with general use Refer to the nebulizers owner s manual Disposable nebulizers should last 30 days For disposable nebulizers it is recommended that an extra nebulizer be kept at all times Refer to the disposable nebulizer s owner s manual Filter Change 1 The filter MUST be replaced after approximately 30 hours of use or when it turns grey 2 Open the filter holder to replace the filter with a new one CAUTION DO NOT use cotton or any other material DO NOT wash or clean the filter Use only Invacare filters DO NOT operate unit without an air filter Invacare Pediatric Bear 26 Part No 1160837 SECTION 5 TROUBLESHOOTING SECTION 5 TROUBLESHOOTING PROBLEM SOLUTION 1 Make sure the plug is firmly fitted to the wall socket 2 Try plugging into another wall socket that is known to work 3 Contact your Invacare dealer Device does not switch ON Device does not nebulize or it nebulizes weakly Part No 1160837 Make sure that the ends of the air tubing are fitted tightly onto the main unit and onto the nebulizer 2 Check whether the nebulizer is empty of medication or has too much medication MAX 6ml 3 Check whether the nebuliz
9. CC 3 T position 9 Place mouthpiece between your teeth close your mouth and tilt the nebulizer toward your FIGURE 2 2 Using the mouth Nebulizer As aerosol begins to flow inhale deeply slowly and hold breath for ten seconds Then exhale slowly through the mouthpiece NOTE If you need to rest during a treatment be sure the nebulizer remains in an upright position otherwise the medication may spill 4 When treatment is complete turn the unit off by setting the switch to the O position and unplug the unit from the electrical outlet Before storing supplies between treatments clean and dry the nebulizer and accessories Refer to Cleaning and Disinfecting on page 21 Part No 1160837 19 Invacare Pediatric Bear SECTION 2 OPERATING INSTRUCTIONS Treatment Instructions for Mask 1 Attach nebulizer cup to mask NOTE For this procedure refer to FIGURE 2 3 2 Place mask on face 3 Turn the unit on pressing the ON OFF switch to the T position 4 As Aerosol begins to flow inhale deeply slowly and hold breath for ten seconds Then FIGURE 2 3 Using the Mask exhale slowly through the mask NOTE If you need to rest during a treatment be sure the mask and nebulizer remain in an upright position otherwise the medication may spill 5 When treatment is complete turn the unit off by setting the switch to the O position and unplug the unit from the electrical outlet
10. ERATION MAINTENANCE OR STORAGE PRODUCTS MODIFIED WITHOUT INVACARE S EXPRESS WRITTEN CONSENT INCLUDING BUT NOT LIMITED TO MODIFICATION THROUGH THE USE OF UNAUTHORIZED PARTS OR ATTACHMENTS PRODUCTS DAMAGED BY REASON OF REPAIRS MADE TO ANY COMPONENT WITHOUT THE SPECIFIC CONSENT OF INVACARE PRODUCTS DAMAGED BY CIRCUMSTANCES BEYOND INVACARE S CONTROL OR PRODUCTS REPAIRED BY ANYONE OTHER THAN INVACARE OR AN AUTHORIZED INVACARE SERVICE CENTER SUCH EVALUATION SHALL BE SOLELY DETERMINED BY INVACARE Invacare Pediatric Bear 30 Part No 1160837 LIMITED WARRANTY THE FOREGOING EXPRESS WARRANTY IS EXCLUSIVE AND IN LIEU OF ANY OTHER WARRANTIES WHATSOEVER WHETHER EXPRESSED OR IMPLIED INCLUDING THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE AND THE SOLE REMEDY FOR VIOLATIONS OF ANY WARRANTY WHATSOEVER SHALL BE LIMITED TO REPAIR OR REPLACEMENT OF THE DEFECTIVE PRODUCT PURSUANT TO THE TERMS CONTAINED HEREIN THE APPLICATION OF ANY IMPLIED WARRANTY WHATSOEVER SHALL NOT EXTEND BEYOND THE DURATION OF THE EXPRESS WARRANTY PROVIDED HEREIN INVACARE SHALL NOT BE LIABLE FOR ANY CONSEQUENTIAL OR INCIDENTAL DAMAGES WHATSOEVER SOME STATES DO NOT ALLOW THE EXCLUSION OR LIMITATION OF INCIDENTAL OR CONSEQUENTIAL DAMAGE OR LIMITATION OF HOW LONG AN IMPLIED WARRANTY LASTS SO THE ABOVE EXCLUSION AND LIMITATION MAY NOT BE APPLICABLE THIS WARRANTY SHALL BE EXTENDED TO COMPLY WITH STATE PROVINCIAL LAWS AND REQUI
11. Operator s Manual Invacare Pediatric Bear Nebulizer System Compressor Nebulizer System Model IRC 1740 Dealer This manual MUST be given to the end user User BEFORE using this product read this manual and save for future reference For more information regarding Invacare products parts and services please visit www invacare com Yes you can A WARNING DO NOT use this product or any available optional equipment without first completely reading and understanding these instructions and any additional instructional material such as owner s manuals service manuals or instruction sheets supplied with this product or optional equipment If you are unable to understand the warnings cautions or instructions contact a healthcare professional dealer or technical personnel before attempting to use this equipment otherwise injury or damage may occur Invacare products are specifically designed and manufactured for use in conjunction with Invacare accessories Accessories designed by other manufacturers have not been tested by Invacare and are not recommended for use with Invacare products A WARNING This is NOT a toy When not administering treatment keep out of the reach of small children Some of the parts of the nebulizer are small enough for children to swallow Small parts may present a choking hazard Invacare Pediatric Bear 2 Part No 1160837 TABLE OF CONTENTS T
12. REMENTS Part No 1160837 31 Invacare Pediatric Bear Yes you can Invacare Corporation www invacare com USA One Invacare Way Elyria Ohio USA 44036 2125 800 333 6900 In Florida 2101 E Lake Mary Blvd Sanford Florida 32773 800 832 4707 All rights reserved Trademarks are identified by the symbols and All trademarks are owned by or licensed to Invacare Corporation or its subsidiaries unless otherwise noted 2008 Invacare Corporation Part No 1160837 Rev A 12 08
13. ations Clean the nebulizer and mask after each aerosol treatment e ALWAYS use fresh cleaning solution e DO NOT towel dry the nebulizer components or mask after cleaning DO NOT boil the mask damage will occur NOTE Your physician and or an Invacare dealer may specify certain cleaning procedures If so follow their recommendations If not clean according to the following instructions Invacare Pediatric Bear 22 Part No 1160837 6 7 SECTION 3 CLEANING AND DISINFECTING Remove the nebulizer and mouthpiece from the tubing If using the mask remove the mask from the nebulizer Disassemble nebulizer chamber by turning counterclockwise and separating Fill two plastic containers or bowls A Washing Hot water detergent solution B Soaking Hot water vinegar solution one part vinegar to three parts water Thoroughly clean the nebulizer mouthpiece and mask in hot water detergent solution Remove from the water detergent solution and rinse with clear hot tap water Soak in hot water vinegar solution for 30 minutes Rinse with hot tap water again and air dry thoroughly NOTE If using medical disinfectant cleaners follow manufacturer s instructions carefully 8 Keep the outer surface of the tubing dust free by wiping regularly NOTE The nebulizer air tubing does not have to be washed internally because only filtered air passes through the tubing Part No 1160837 23 Invacare Pediatric B
14. cup of the nebulizer using an eyedropper pre measured dose or ampoule Eyedropper Nebulizer Cup FIGURE 2 1 Adding Medication 5 Gently twist the top and bottom sections together clockwise to assemble the nebulizer Be sure the two sections fit securely 6 Attach one end of the air tubing to the air tubing connector located on the back of the compressor Part No 1160837 17 Invacare Pediatric Bear SECTION 2 OPERATING INSTRUCTIONS 7 Attach the other end of the air tubing to the base of the nebulizer NOTE Ensure nebulizer tubing is firmly attached to compressor before use A WARNING In the case of high humidity condensation may form inside the tubing Run the unit for two minutes before connecting the nebulizer to the tubing 8 Attach the mouthpiece to the top section of the nebulizer Refer to the nebulizer manual for additional instructions NOTE Before starting a cold unit let the unit reach room temperature in a heated area 9 With the power switch off plug the power cord into an appropriate electrical outlet CAUTION This device is for intermittent use 20 min ON 40 min OFF Failure to operate within these limits could damage the device beyond repair Invacare Pediatric Bear 18 Part No 1160837 SECTION 2 OPERATING INSTRUCTIONS Treatment Instructions for Nebulizer NOTE For this procedure refer to FIGURE 2 2 1 Turn the unit on pressing the ON OFF switch to the
15. ear SECTION 3 CLEANING AND DISINFECTING Cleaning the Compressor CAUTION Unplug unit before cleaning DO NOT submerge in water to clean DO NOT clean using abrasive cleaners 1 Clean the casing of the main unit daily by using a soft cloth moistened with water or a mild detergent 2 Wipe the casing and immediately dry using a soft clean cloth Cleaning the Mouthpiece 1 Boil the mouthpiece in water for a maximum of five minutes or autoclave at a maximum of 121 C for ten minutes 2 Allow the mouthpiece to air dry 3 Once dry the mouthpiece may be stored inside the nebulizer top Invacare Pediatric Bear 24 Part No 1160837 SECTION 4 MAINTENANCE SECTION 4 MAINTENANCE A DANGER DO NOT attempt to separate the outer case of this unit Removing the case creates a serious electrical shock hazard All disassembly and maintenance of this unit MUST be done by a qualified technician Routine Care To keep your device in the best condition and protect the unit from damage follow these directions e DO NOT subject the device the parts to any strong shocks such as dropping the device on the floor e DO NOT store the device in extreme hot or cold temperatures high humidity or under direct sunlight Storage Store the repackaged device in a dry and safe area DO NOT place other objects on top of the repackaged device Part No 1160837 25 Invacare Pediatric Bear SECTION 4 MAINTEN
16. er nozzle is obstructed 4 Check whether the medication pick up insert is in place If these possible solutions DO NOT work contact your Invacare dealer 27 Invacare Pediatric Bear SECTION 5 TROUBLESHOOTING NOTES Invacare Pediatric Bear 28 Part No 1160837 LIMITED WARRANTY LIMITED WARRANTY PLEASE NOTE THE WARRANTY BELOW HAS BEEN DRAFTED TO COMPLY WITH FEDERAL LAW APPLICABLE TO PRODUCTS MANUFACTURED AFTER JULY 4 1975 This warranty is extended only to the original purchaser who purchases this product when new and unused from Invacare Corporation or a dealer This warranty is not extended to any other person or entity and is not transferable or assignable to any subsequent purchaser or owner Coverage under this warranty will end upon any such subsequent sale or other transfer of title to any other person This warranty gives you specific legal rights and you may also have other legal rights which vary from state to state Invacare warrants this product when purchased new and unused to be free from defects in materials and workmanship for a period of 5 years from date of purchase from Invacare or a dealer with a copy of the seller s invoice required for coverage under this warranty If within such warranty period any such product shall be proven to Invacare s satisfaction to be defective such product shall be repaired or replaced at Invacare s option This warranty does not apply to normal wear and tear or
17. ngs may be blocked Keep the air openings free from lint hair and the like Blocked openings may cause the unit to shut down Contact dealer immediately The compressor nebulizer system uses the surrounding air to effectively administer the prescribed medication through the nebulizer The user and administrator should be aware of surroundings so as not to have contaminated air filtered through the compressor nebulizer system Examples can be air contaminated with paint or cleaning fumes weed killer car exhaust etc DO NOT use the compressor nebulizer system in these environments Otherwise serious bodily injury may occur This unit is oil less DO NOT lubricate Part No 1160837 9 Invacare Pediatric Bear IMPORTANT SAFEGUARDS A WARNING This equipment is not suitable for use in the presence of a flammable anesthetic mixture with air or with nitrous oxide When not administering treatment keep out of the reach of small children Some of the parts of the nebulizer are small enough for children to swallow The tubing may present a strangulation hazard NEVER touch the unit with wet hands DO NOT pull on the power cord to unplug the unit from an electrical outlet DO NOT overload wall outlets Maintenance MUST be performed by a qualified service technician SAVE THESE INSTRUCTIONS Invacare Pediatric Bear 10 Part No 1160837 INTRODUCTION INTRODUCTION The Invacare Pediatric Bear Nebulizer System i
18. or your local Invacare dealer 2 Remove all the loose packing from the carton 3 Carefully remove all the components from the carton NOTE Retain carton and packing materials for use in shipping or storing the unit until use is required Inspection 1 Examine exterior for damage Inspect all components Part No 1160837 15 Invacare Pediatric Bear SECTION 2 OPERATING INSTRUCTIONS SECTION 2 OPERATING INSTRUCTIONS A WARNING DO NOT operate unit without filter Avoid operating this product in a dusty environment Otherwise premature compressor wear could occur NOTE Clean and disinfect the nebulizer mouthpiece and mask before using the device for the first time Refer to Cleaning and Disinfecting on page 21 Setup NOTE For this procedure refer to FIGURE 2 1 on page 17 1 Place the unit ona table or other flat stable surface Be sure you can easily reach the controls when you are seated CAUTION Make sure the power switch is in the off O position 2 Gently twist the nebulizer counterclockwise to separate it into two sections Invacare Pediatric Bear 16 Part No 1160837 SECTION 2 OPERATING INSTRUCTIONS 3 Be sure the medication pick up insert is in place in the bottom section of the nebulizer CAUTION DO NOT add over 6 ml of medication to the medication cup The maximum capacity of the nebulizer medication cup is 6 ml 4 Add the prescribed amount of medication to the
19. s a portable medical device designed to efficiently deliver physician prescribed medication to the bronchial lung passages The nebulizer system consists of the following components Compressor Nebulizer Air tubing Mouthpiece Pediatric Mask Part No 1160837 II Pediatric Bear TYPICAL PRODUCT PARAMETERS TYPICAL PRODUCT PARAMETERS Electrical Requirements 120 VAC 60Hz Single Phase Running Current 1 4 12 4 15 4 psi 120 volts Sound Level 58 dBA Power Wattage 68 watts 18 psig Electric Motor Class in compliance with 2111 Foam Intake Filter Safety Systems Polyurethane Sponge High temperature compressor shutdown Width 6 5 inches Height 8 2 inches Depth 5 5 inches Weight 3 4 Ibs Shipping Weight 3 8 Ibs Regulatory Listing In compliance with UL 60601 1 Typical Operating Pressure 12 4 to 15 4 psi Maximum Pressure 30 to 35 psi Operating Flow Rate 4 0 Limin 16 psi operating pressure Maximum Flow Rate Invacare Pediatric Bear 5 to 7 L min 12 Part No 1160837 Storage Conditions TYPICAL PRODUCT PARAMETERS 13 F to 158 F 25 to 70 C 10 to 90 RH Operating Conditions 50 F to 104 F 10 C to 40 C 30 to 75 RH Altitude 0 to 6000 ft 1825 m above sea level Mode of Operation Intermittent Use 20 min ON 40 min OFF NOTE Product parameters and