Home
Intel MPRTM4808 User's Manual
Contents
1. emm 13 6 Floppy Connector PIROLL eec d icone a dees datus e a aaa saa kaka 14 IPMB1 Connector u u u L hh nennt ER Ra eta E Ho E RR 14 9 1 Connector PIDOUL esae trt aee PAREN Ru 15 9 PMGC2 Connector PIDOUt conecte tte en e kx Re sus 16 10 Location of SWIUCHeS esie sacked net Ein 17 11 Connecting Intel NetStructure MPRTM4808 Rear Transition Board to Backplane 18 12 J3 Connector Pinout Rows 19 13 Connector Pinout Rows D 20 14 4 5 Connector Pinout Rows 20 15 4 5 Connector Pinout Rows D RENNEN 21 16 Front Panel Connectors and 22 17 Connector a 23 18 5 2 Keyboard Mouse Connector 23 19 USB Gonnector eene to hene IER RIEN I OO RA a N i 24 20 COM Connector PINOUT uide xd eus ded aea aad 24 21 DB9 to SJ 45 Translation sssaaa 25 22 ROSS Key 25 Tables 1 Termsand Deflhitlons ett
2. C 3 2 Standard Compliances 3 3 On Board Connectors eiie ier at iei I dee 3 3 1 Secondary EIDE 3 9 2 Floppy Disk Drive erdt a a hae e tees 3 3 3 Intelligent Peripheral Management Bus 334 PMC VO Signals iine oet iei et aquya ee 9 4 Owitcli Settings kuu uuu re eed u 3 5 Installing and Removing the 3 5 1 Installation Procedure 3 5 2 Removal 3 6 CompactPCI Connectors 3 Front Panel Connectors and Controls 3 1 3 7 2 5 2 Keyboard or 3 7 3 Serial Conriectors RENE 3 7 4 Reset Key iid ane ed eee tra ted 4 Agency Approvals U nemen nennen enn 44 CE CertflGation eie itte e exe ra care ni e aa 4 2 Safety Certifieatlofs u uuu aaa eene 4 3 Emissions Test Regulations 4 3 1 EN 50081 1 Emissions
3. Installation 3 3 1 Caution 3 3 1 1 Figure 3 3 3 1 2 12 intel Secondary EIDE Interface The Intel MPRTM4808 board provides the secondary EIDE interface via CompactPCI connector J5 The secondary EIDE interface can be used for One EIDE device Two EIDE devices One EIDE device and one CompactFlash disk If more than two IDE devices are connected to the IDE bus the bus is unable to recognize all of the devices and the baseboard might not start correctly Therefore only connect up to two devices to the secondary EIDE interface on the Intel MPRTM4808 board If the secondary EIDE interface on the Intel MPRTM4808 board is connected to an external device the board is hot swappable but data may get lost Therefore always save data on disk before installing or removing the baseboard under hot swap conditions Hard Disk Drives Hard disk drives are connected to the secondary EIDE interface via an EIDE connector It is implemented with a 40 pin 2 54 mm pin pitch connector The following connector pinout shows how the pins are assigned EIDE Connector Pinout HDRESET GND D7 08 06 09 05 010 04 011 03 012 02 013 01 014 00 015 GND DREQ GND NOW GND NOR GND IOCHRDY fe DACKO GND IRQ14 n c Al S IDE PDIAG N A2 50 ICS1 DASP GND CompactFlash Disk CompactFlash is slave by default If used it should be configured as master set SW3 1 to ON The flash disk is conne
4. This product generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense This device complies with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference 2 This device must accept any interference received including interference that may cause undesired operation If you make any modification to the equipment not expressly approved by Intel you could void your authority to operate the equipment Industry Canada Canada Cet appareil num rique respecte les limites bruits radio lectriques applicables aux appareils num riques de Classe A prescrites dans la norme sur le mat riel brouilleur Appareils Num riques NMB 003 dict e par le Ministre Canadien des Communications This digital apparatus does not exceed the Class A limits for radio noise emissions from digital apparatus set out in the interference causing equipment standard entitled Digital Apparatus ICES 003 of the Canadian Department of Communications Intel NetStructure MPRTM4808 Rear Transition Board Installation Guide 27 Agency Approvals ntel 4 5 4 5 1 28 Caution C
5. Installation Unfasten screws of front panel until Intel MPRTM4808 board is detached from rack frame Carefully remove Intel MPRTM4808 board from slot making sure not to bend any pins The Intel MPRTM4808 board provides CompactPCI connectors J3 J4 J5 The connector pinouts in Figure 12 through Figure 15 show how the pins are assigned J3 Connector Pinout Rows A C 9 8 7 6 5 4 3 2 4 AS GND ETH 0 TXP DA P ETH 0 RXP DB P ETH 1 TXP DA P ETH 1 RXP DB P GND _1_105 1 1010 1 1015 1 1020 PMC 1 1025 1 1030 1 1035 PMC 171040 PMC 1 1045 PMC 1 1050 1 1055 1 1060 VP5 RTB GND ETH 0 TXN DA N ETH 0 RXN DB ETH 1 TXN DA N ETH 1 RXN DB N GND 1 IO4 1 109 11014 1 1019 1 1024 _1 1029 PMC 1 1034 PMC 1 1039 PMC 1 1044 1 1049 1 1054 1 1059 PMC 1 1064 GND GND GND GND GND GND 1 103 1 108 1 1013 PMC 1 1018 PMC 1 1023 1 1028 PMC 1 1033 PMC 1 1038 1 1043 1 1048 1 1053 11058 11063 Intel NetStructure MPRTM4808 Rear Transition Board Installation Guide 19 Installation Figure 13 Figure 14 20 J3 Connector Pinout Rows D and E GND NC ETH 0 D NC ETH 0 D NC ETH 1 D NC ETH 1 D GND 1 102 PMC 1 107 1 1012 PMC 1 1017 PMC 1 1022
6. a 4 3 2 55024 Immunity iei endete 4 4 Regulatory Information eene 447 USA u 4 4 2 Industry Canada 45 Product Safety 4 5 1 Safety Precautions eene 4 6 AC and or DC Power Safety Warning AC and or DC Powered Units 4 7 Rack Mount Enclosure Safety a Intel NetStructure MPRTM4808 Rear Transition Board Installation Guide Contents Contents ntel 5 Warranty IBfofifaliphh HE 30 5 1 Intel NetStructure Compute Boards amp Platform Products Limited Warranty 30 5 1 1 Returning a Defective Product RMA emnes 30 6 Customer SUPPO pu 33 6 1 Technical Support and Return for Service Assistance 33 6 2 Sales ASSISIaFICe 33 Figures 1 Location of IPMB1 and ICMB Connectors 10 2 On Board CoOmnmectors 11 3 EIDE Connector Pinout esa eeu ha 12 4 Location of CompactFlash Slot uuu u ttn ttn ttd 13 5 Inserting a CompactFlash Disk into Socket
7. interface cables to the front panel connectors after installing the Intel MPRTMAS0S8 board 1 2 3 4 Check all installed boards for steps to perform before turning off system power Turn off system power Check system documentation for switch settings The Intel MPRTM4808 board provides two on board switches and one FP reset switch Make sure that switches are set to OFF default position Connect interface cables to on board connectors Insert the Intel MPRTM4808 board carefully from rear into same slot as the CPU board making sure not to bend any pins Figure 11 Connecting Intel NetStructure MPRTM4808 Rear Transition Board to Backplane CompactPCI Backplane 10 18 Press handles inward to lock Intel MPRTM4808 board on CompactPCI rack Fasten Intel MPRTM4808 board with screws Plug interface cables into front panel connectors if applicable see Section 3 7 Front Panel Connectors and Controls on page 22 Turn on system power Intel NetStructure MPRTM4808 Rear Transition Board Installation Guide intel 3 5 2 3 6 Figure 12 Removal Procedure Q dB 795 Turn off system power Turn on system power Unlock handles by pressing on red handle buttons Press handles outward to disconnect the Intel MPRTM4808 board from backplane CompactPCI Connectors Check all installed boards for steps to perform before turning off power
8. 336 EEC for Electromagnetic Compatibility and Low Voltage Directive 73 23 EEC for Product Safety The Intel MPRTM4808 board has been designed for NEBS ETSI compliance Safety Certifications UL cUL 60950 Safety for Information Technology Equipment UL File E179737 EN IEC 60950 Safety for Information Technology Equipment CB Report Scheme CB certificate and Report Emissions Test Regulations FCC Part 15 Subpart B EN 55022 CISPR 22 Bellcore GR 1089 EN 50081 1 Emissions GR 1089 CORE Sections 2 and 3 EN 55022 Class A Radiated EN 55022 Power Line Conducted Emissions EN 61000 3 2 Power Line Harmonic Emissions EN 61000 3 3 Power line Fluctuation and Flicker Intel NetStructure MPRTM4808 Rear Transition Board Installation Guide Intel 4 3 2 4 4 4 4 1 Note Caution 4 4 2 Agency Approvals EN 55024 Immunity GR 1089 CORE Sections 2 and 3 EN 61000 4 2 Electro Static Discharge ESD EN 61000 4 3 Radiated Susceptibility EN 61000 4 4 Electrical Fast Transient Burst EN 61000 4 5 Power Line Surge EN 61000 4 6 Frequency Magnetic Fields EN 61000 4 11 Voltage dips Variations and Short Interruptions Regulatory Information FCC USA This product has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment
9. PMC 1 1027 1 1032 11037 1 1042 1 1047 PMC 1 1052 1 1057 PMC 1 1062 C P DP DP i si GND NC ETH_0_ NC ETH_0_ 1 1 GND PMC 1101 1106 111011 11016 1 1021 PMC 1 1026 1 1031 PMC 1 1036 1 1041 1 1046 1 1051 PMC 111056 1 1061 DC N DD DC N DD N NC IPMB1 DAT NC IPMB1 CLK NC COM 1 CTS COM 1 RTS COM 1 RXD COM 1 TXD FD DENSEL FD DSKCHG N FD WP DAT IDE BRSDR N IDE A2 IDE A1 IDE 0 IDE D7 IDE D2 IDE USB VCCO EXTSMI 9 8 7 6 5 4 3 2 1 NC RXD NC ICMB TXD NC COM2 CTS COM2 RTS COM2 RXD COM2 TXD FD RDATA N NC NC NC NC NC COM1 DTR 2 COM1 DCD COM2 DCD FD WDATA N FD INDEX N FD MTR1 RTB CLK IDE IORDY IDE IOR N IDE D15 IDE D11 IDE D6 IDE D1 GND USB PO N VP5 FD TRKO FD MTRO VP5 RTB V2P5 ETHREF IDE IDE D14 IDE D10 IDE D5 IDE DO GND USB V3P3 RTB 9 8 7 6 5 4 3 2 1 Intel NetStructure MPRTM4808 Rear Transition Board Installation Guide intel Figure 15 Intel NetStructure MPRTM4808 Rear Transition Board Installation Guide J5 Connector Pinout Rows D and E Installation 9 8 7 6 5 4 3 2 1 NC NC NC NC NC COM1 DSR COM2 DSR COMI RI 2 RI FD
10. Transition Board Installation Guide 13 Installation 3 3 1 4 3 3 2 Note Figure 6 3 3 3 Figure 7 14 intel Removal Procedure Turn off CPU power Press ejector pin The ejector pin loosens the CompactFlash disk from the socket Remove CompactFlash disk from Intel 4808 board 99 N Turn on CPU power Floppy Disk Drive The board is not hot swappable if a floppy disk drive is connected to the Intel MPRTM4808 board The floppy disk drive connector is a 34 pin 2 54 mm pin pitch connector The following connector pinout shows how the pins are assigned Floppy Connector Pinout Intelligent Peripheral Management Bus IPMB The Intelligent Peripheral Management Bus 1 IPMB1 can be used to connect control and monitor critical components such as power supply units fans etc It provides information on the system inventory temperature voltage level etc is routed to CompactPCI connector J5 In addition the Intel 4808 board provides the IPMBI connector to attach the system management bus via J5 In accordance with PICMG Specification 2 9 the board uses a Molex 53398 0590 connector The following connector pinout shows how the pins are assigned IPMB1 Connector Pinout IPMB1 CLK GND IPMB1_DAT VP5 IPMB1 ALERT Intel NetStructure MPRTM4808 Rear Transition Board Installation Guide intel 3 3 4
11. WGATE N FD STEP N FD DR1 N V3P3 RTB IDE DREQ IDE CS1 N IDE D13 IDE D9 IDE D4 IDE IRQ GND RTB GPO VP5 SMB ALERT NC KB DAT KB CLK MS DAT MS CLK FD HDSEL N FD DIR N FD DRO FD DRATEO IDE DACK N IDE CSO IDE D12 IDE D8 IDE D3 NC VP5 RTB RTB PRES N RTB RSTN N ESE co 9 8 y 6 5 4 3 2 1 21 Installation ntel 3 7 Front Panel Connectors and Controls The Intel 4808 board front panel provides the following connectors and controls Figure 16 Front Panel Connectors and Controls 61 N Noo 0 N zoo The Intel 4808 board provides several RJ 45 connectors that commonly serve as different interfaces RS 485 twisted pair Ethernet and telephone Connecting different interfaces e g Ethernet and RS 485 may damage the board Therefore make sure that you only connect matching interfaces Furthermore take note of the following Caution Clearly mark TPE connectors near your working area as network connectors Connect TPE bushing of the system to safety extra low voltages SELV circuits only Ensure that the length of electric cable connected to TPE bushing does not exceed 100 meters 22 Intel NetStructure MPRTM4808 Rear Transition Board Installation Guide Intel 3 7 1 Figure 17 3 7 2 Figure 18 Installation ICMB Connector The ICMB connector c
12. frequency energy and if not installed properly and used in accordance with this Installation Guide may cause harmful interference to radio communications Operating the system in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense If boards are integrated into open systems always cover empty slots Switch Settings The board provides two onboard switches and one FP reset switch The switches must be set to OFF upon initial installation of the board Refer to Section 3 4 Switch Settings on page 17 for additional configurations Intel NetStructure MPRTM4808 Rear Transition Board Installation Guide 7 Operating Safety ntel 2 3 2 4 2 5 Installation Electrostatic discharge and incorrect board installation and removal can damage circuits or shorten their life Therefore Make sure that you are working in an ESD safe environment before touching boards or electronic components When plugging in or removing the board do not press or pull on the front panel use the handles Before installing or removing an additional device or module read the device s documentation Make sure that the board is connected to the CompactPCI backplane via all assembled connectors and that power is available on all power pins Only install and use the rear transition module with CPU boards especially designed for it Otherwise both
13. the CPU board and the rear transition module may be damaged Make sure to use only the backplane s rear slot position Operation When operating the Intel MPRTM4808 board in areas of electromagnetic radiation ensure that the board is bolted on the CompactPCI system and the system is shielded by enclosure Make sure that the board s contacts and cables cannot be touched while the board is operating Do not operate the board outside the specified environmental limits High humidity and condensation may cause short circuits Make sure the product is completely dry and there is no moisture on any surface before applying power Do not operate the product below 0 C Replacement Expansion Only replace or expand components or system parts with those recommended by Intel Otherwise you are fully responsible for the impact on EMC or any possible malfunction of the product Check the total power consumption of all components installed and ensure that any individual output current of any source stays within its acceptable limits See the technical specification of the respective source If more than two IDE devices are connected to the IDE bus the bus is not able to recognize all of the devices and the Intel 4808 board might not start correctly Therefore only connect up to two devices to the secondary EIDE interface on the RTB If the secondary EIDE interface on the Intel MPRTM4808 board is connected to an external device data
14. ERCHANTABILITY FITNESS FOR A PARTICULAR PURPOSE ANY WARRANTY OF INFRINGEMENT OF ANY OTHER PARTY S INTELLECTUAL PROPERTY RIGHTS OR ANY WARRANTY ARISING OUT OF ANY PROPOSAL SPECIFICATION OR SAMPLE This warranty does not cover replacement of products damaged by abuse accident misuse neglect alteration repair disaster improper installation or improper testing If the product is found to be otherwise defective Intel at its option will replace or repair the product at no charge except as set forth below provided that you deliver the product along with a return material authorization RMA number see below either to the company from whom you purchased it or to Intel If you ship the product you must assume the risk of damage or loss in transit You must use the original container or the equivalent and pay the shipping charge Intel may replace or repair the product with either a new or reconditioned product and the returned product becomes Intel s property Intel warrants the repaired or replaced product to be free from defects in material and workmanship for a period of the greater of i ninety 90 days from the return shipping date or ii the period of time remaining on the original two 2 year warranty This warranty gives you specific legal rights and you may have other rights which vary from state to state All parts or components contained in this product are covered by Intel s limited warranty for this product The product ma
15. Intel NetStructure MPRTM4808 Rear Transition Board Installation Guide December 2004 Order Number 301370 002 INFORMATION IN THIS DOCUMENT IS PROVIDED IN CONNECTION WITH INTELR PRODUCTS EXCEPT AS PROVIDED IN INTEL S TERMS AND CONDITIONS OF SALE FOR SUCH PRODUCTS INTEL ASSUMES NO LIABILITY WHATSOEVER AND INTEL DISCLAIMS ANY EXPRESS OR IMPLIED WARRANTY RELATING TO SALE AND OR USE OF INTEL PRODUCTS INCLUDING LIABILITY OR WARRANTIES RELATING TO FITNESS FOR A PARTICULAR PURPOSE MERCHANTABILITY OR INFRINGEMENT OF ANY PATENT COPYRIGHT OR OTHER INTELLECTUAL PROPERTY RIGHT Intel Corporation may have patents or pending patent applications trademarks copyrights or other intellectual property rights that relate to the presented subject matter The furnishing of documents and other materials and information does not provide any license express or implied by estoppel or otherwise to any such patents trademarks copyrights or other intellectual property rights Intel products are not intended for use in medical life saving life sustaining critical control or safety systems or in nuclear facility applications Intel may make changes to specifications and product descriptions at any time without notice Designers must not rely on the absence or characteristics of any features or instructions marked reserved or undefined Intel reserves these for future definition and shall have no responsibility whatsoever for conflicts or inco
16. REGOING INTEL S TOTAL LIABILITY FOR ALL CLAIMS UNDER THIS AGREEMENT SHALL NOT EXCEED THE PRICE PAID FOR THE PRODUCT THESE LIMITATIONS ON POTENTIAL LIABILITIES WERE AN ESSENTIAL ELEMENT IN SETTING THE PRODUCT PRICE INTEL NEITHER ASSUMES NOR AUTHORIZES ANYONE TO ASSUME FOR IT ANY OTHER LIABILITIES Some states do not allow the exclusion or limitation of incidental or consequential damages so the above limitations or exclusions may not apply to you Intel NetStructure MPRTM4808 Rear Transition Board Installation Guide ntel Customer Support Customer Support 6 This section offers technical and sales assistance information for this product and information on returning an Intel NetStructure product for service 6 1 Technical Support and Return for Service Assistance For all product returns and support issues please contact your Intel product distributor or Intel sales representative for specific information 6 2 Sales Assistance If you have a sales question please contact your local Intel NetStructure sales representative or the regional sales office for your area Address telephone and fax numbers and additional information is available at Intel s website located at http www intel com network csp sales Intel Corporation Telephone in U S 1 800 755 4444 Telephone Outside U S 1 973 993 3030 FAX 1 973 967 8780 Intel NetStructure MPRTM4808 Rear Transition Board Installation Guide 33
17. Signals Installation The I O signals of PMC Slots 1 and 2 of the CPU board are routed to two 64 pin connectors Figure 8 and Figure 9 show the pinouts Figure 8 PMC 1 Connector Pinout oo oo oo oo oo oo oo oo oo oo oo oo oo oo Le e oo e e oo oo oo oo oo oo oo Le e NC NC NC NC V3 3 NC NC NC GND NC NC NC V3 3 NC NC NC GND NC NC NC V3 3 NC NC NC GND NC NC NC V3 3 NC NC NC Intel NetStructure MPRTM4808 Rear Transition Board Installation Guide 15 Installation n Figure 9 PMC 2 Connector Pinout PMC 101 PMC 1033 PMC 102 1034 103 1035 104 1036 105 1037 106 oo PMC_1038 PMC 107 ix PMC 1039 1O8 1040 109 It PMC 1041 PMC 1010 CX PMC 1042 1011 25 1043 1012 PMC 1044 PMC 1013 1045 PMC 1014 oo PMC 1046 PMC 1015 1047 1016 oo 1048 1017 Er PMC 1049 PMC 1018 mo 1050 PMC 1019 22 PMC 1051 1020 oo PMC 1052 1021 T PMC 1053 PMC 1022 oo PMC_1054 PMC_1023 ii PMC 1055 1024 oo PMC 1056 PMC 1025 if PMC 1057 PMC 1026 oo PMC 1058 PMC 1027 PMC_IO59 PMC 1028 1060 1029 1061 1030 1062 PMC 1031 PMC 1063 PMC 1032 1064 16 Intel NetStructure MPRTM4808 Rear Tra
18. all hot swappable equipment for optimum weight reduction Be sure to mount your system in a way that ensures even loading of the rack Uneven mechanical loading of weight can result in a hazardous condition Secure all mounting bolts when installing the enclosure to the frame rack Avoid Electric Overload To avoid electric shock or fire hazard only connect your system to an input voltage source as specified in the product user manual Intel NetStructure MPRTM4808 Rear Transition Board Installation Guide 29 a Warranty Information ntel Warranty Information 5 5 1 5 1 1 30 Intel NetStructure Compute Boards amp Platform Products Limited Warranty Intel warrants to the original owner that the product delivered in this package will be free from defects in material and workmanship for two 2 year s following the latter of i the date of purchase only if you register by returning the registration card as indicated thereon with proof of purchase or ii the date of manufacture or iii the registration date if by electronic means provided such registration occurs within 30 days from purchase This warranty does not cover the product if it is damaged in the process of being installed Intel recommends that you have the company from whom you purchased this product install the product THE ABOVE WARRANTY IS IN LIEU OF ANY OTHER WARRANTY WHETHER EXPRESS IMPLIED OR STATUTORY INCLUDING BUT NOT LIMITED TO ANY WARRANTY OF M
19. an be used to attach the Intel NetStructure MPCBL5525 System Master Board via the Intel MPRTM4808 board to other systems based the IPMI To monitor the overall system the chassis can be connected via the Intel MPRTM4808 boards The IPMI signals routed from the CPU via the backplane to the Intel 4808 board and are then available on the ICMB connector The ICMB bus must be connected via a multi drop cable or star topology The following figure shows how the pins are assigned ICMB Connector Pinout co O Q 2020 ozoz PS 2 Keyboard or Mouse By using a keyboard mouse splitter cable you can use a PS 2 keyboard and a PS 2 mouse at the same time The cable is included in the cable assembly kit This cable may be obtained from Black Box Corporation http www blackbox com or from other qualified vendors PS 2 Keyboard Mouse Connector Pinout Keyboard data GND Keyboard clock Mouse data Vcc Mouse clock Intel NetStructure MPRTM4808 Rear Transition Board Installation Guide 23 Installation ntel iB 3 7 3 Serial Connectors Two serial devices can be connected via the two COM connectors and one USB device e g USB keyboard USB mouse can be connected via the USB connector Note two COM ports are only available if the Intel MPRTM4808 board is used together with the Intel NetStructure MPCBL5525 System Master Board Figure 19 shows how the USB con
20. aution Caution Caution Caution Caution Caution Caution Warning Caution Product Safety Information Safety Precautions Review the following precautions to avoid injury and prevent damage to this product or any products to which it is connected To avoid potential hazards use the product only as specified Read all safety information provided in the component product user manuals and understand the precautions associated with safety symbols written warnings and cautions before accessing parts or locations within the unit Save this document for future reference To Avoid Electric Overload To avoid electrical hazards heat shock and or fire hazard do not make connections to terminals outside the range specified for that terminal See the product user manual for correct connections To Avoid the Risk of Electric Shock When supplying power to the system always make connections to a grounded main Always use a power cable with a grounded plug third grounding pin Do not operate in wet damp or condensing conditions System Airflow Requirements Platform components such as processor boards Ethernet switches etc are designed to operate with external airflow Components can be destroyed if they are operated without external airflow Chassis fans normally provide external airflow when components are installed in compatible chassis Filler panels must be installed over unused chassis slots so that airflow re
21. cted to the secondary EIDE interface via a flash disk holder with an ejector at the front panel The CompactFlash slot is integrated into the front panel to allow installation and or removal of a CompactFlash card without having to remove the board from the system Intel NetStructure MPRTM4808 Rear Transition Board Installation Guide Figure 4 Note 3 3 1 3 Note Figure 5 Installation Location of CompactFlash Slot CompactFlash disks of types I and II are supported ram Installation Procedure To configure the card to the supported true IDE mode the card must already be inserted when the board s power is turned on Inserting the CompactFlash while the board s power is still on will configure the CompactFlash disk to PC Card ATA mode which is not supported by the CPU board If you have inserted the card while the board s power has been turned on remove the card and reinsert it with the board s power turned off 1 Consult system documentation and perform any steps required before turning off CPU power 2 Turn off CPU power 3 Check that disk s connectors face CompactFlash socket 4 Plug the CompactFlash disk into socket The CompactFlash disk is connected to the socket 1f the ejector pin on the front panel is pushed out of the recess Inserting a CompactFlash Disk into Socket 5 Turn on CPU power Intel NetStructure MPRTM4808 Rear
22. ety Operating Safety 2 2 1 2 2 This section provides safety precautions to follow when installing operating and maintaining the Intel NetStructure MPRTM4808 Rear Transition Board Intel intends to provide all necessary information to install and handle the Intel 4808 board in this Installation Guide However as the product is complex and its usage manifold Intel does not guarantee that the given information is complete For additional information contact your Intel representative The Intel 4808 board has been designed to meet standard industrial safety requirements It must be used only in the area of office telecommunication and industrial control Only personnel trained by Intel or persons qualified in electronics or electrical engineering are authorized to install maintain and operate the Intel MPRTM4808 board The information given in this manual is meant to complete the knowledge of a specialist and must not be taken as replacement for qualified personnel Electromagnetic Compatibility EMC The Intel MPRTM4808 board has been tested in a standard system and found to comply with the limits for a Class A digital device in this system pursuant to part 15 of the FCC Rules respectively EN 55022 Class A These limits are designed to provide reasonable protection against harmful interference when the system is operated in a commercial business or industrial environment The board generates and uses radio
23. i tu RE EY Rea Y 6 2 Standard 11 3 SWEN 17 4 Intel NetStructure MPRTM4808 Rear Transition Board Installation Guide ntel Contents Date Revision Description May 2004 001 Initial release of this manual December 2004 002 Modified Serial Connectors information Intel NetStructure MPRTM4808 Rear Transition Board Installation Guide 5 Using This Guide I ntel Using This Guide 1 The Intel NetStructure MPRTM4808 Rear Transition Board Installation Guide is intended for users qualified in electronics or electrical engineering Users should have a working understanding of PCI CompactCPCI and telecommunications 1 1 Terms and Definitions Table 1 Terms and Definitions Abbreviation Description EMI Electromagnetic Interference GPO General Purpose ICMB Intelligent Chassis Management Bus IPMB Intelligent Peripheral Management Bus SCSI Small Computer System Interface RTB Rear Transistion Board IPMI Intelligent Plattorm Management Interface SELV Safety Extra Low Voltages 1 2 Other Sources of Information For further information refer to the Intel NetStructure 4808 Rear Transition Board User s Manual Order number 301070 6 Intel NetStructure MPRTM4808 Rear Transition Board Installation Guide intel Operating Saf
24. its The AC and or DC power cord is your unit s main AC and or DC disconnecting device and must be easily accessible at all times Auxiliary AC and or DC On Off switches and or circuit breaker switches are for power control functions only NOT THE MAIN DISCONNECT For your safety use only a power cord with a grounded plug The enclosure is also provided with a separate earth ground connection stud The earth ground connection should be installed prior to the application of power or peripheral connections and should never be disconnected while power or peripheral connections exist To reduce the possibility of electric shock from a telephone or Ethernet system plug your enclosure into the power source before making these connects Disconnect these connections before unplugging your enclosure from the power source Verify Power Cord and Outlet Compatibility Check to ensure you are using the appropriate power cords for your power outlet configurations Visit the following website for additional information http kropla com electric2 htm Rack Mount Enclosure Safety Your enclosure may be intended for stationary rack mounting Mount in a rack designed to meet the physical strength requirements of NEBS GR 63 CORE and NEBS GR 487 Your system may have multiple power sources Disconnect all power sources and external connections cables prior to installing or removing your system from a rack frame Prior to mounting Intel recommends you remove
25. may get lost Therefore always save data on disk before installing or removing the baseboard under hot swap conditions Intel NetStructure MPRTM4808 Rear Transition Board Installation Guide a ntel Operating Safety 2 6 RJ 45 Connector The Intel 4808 board provides several RJ 45 connectors that commonly serve as different interfaces RS 485 twisted pair Ethernet and telephone Connecting different interfaces e g Ethernet and RS 485 may damage the board Therefore make sure that you only connect matching interfaces Furthermore take note of the following Clearly mark TPE connectors near your working area as network connectors Connect TPE bushing of the system to safety extra low voltage SELV circuits only Make sure that the electric cable connected to a TPE bushing does not exceed 100 meters 2 7 Environment Always dispose of used batteries and or old boards according to your country s legislation and in an environmentally acceptable way Intel NetStructure MPRTM4808 Rear Transition Board Installation Guide 9 Installation ntel Installation 3 3 1 Introduction The Intel NetStructurerM MPRTM4808 Rear Transition Board provides easy access to I O signals of boards via the CompactPCI backplane Backplane I O signals are available at connector J5 To connect System Management Bus 1 and the Chassis Management Bus to the board the Intel MPRTM4808 board provides the Intelligent Platfo
26. mpatibilities arising from future changes to them This Installation Guide as well as the software described in it is furnished under license and may only be used or copied in accordance with the terms of the license The information in this manual is furnished for informational use only is subject to change without notice and should not be construed as a commitment by Intel Corporation Intel Corporation assumes no responsibility or liability for any errors or inaccuracies that may appear in this document or any software that may be provided in association with this document Except as permitted by such license no part of this document may be reproduced stored in a retrieval system or transmitted in any form or by any means without the express written consent of Intel Corporation Contact your local Intel sales office or your distributor to obtain the latest specifications and before placing your product order Copies of documents which have an ordering number and are referenced in this document or other Intel literature may be obtained by calling 1 800 548 4725 or by visiting Intel s website at http www intel com AnyPoint AppChoice BoardWatch BunnyPeople CablePort Celeron Chips CT Media Dialogic DM3 EtherExpress ETOX FlashFile i386 i486 i960 iCOMP InstantlP Intel Intel Centrino Intel logo Intel386 Intel486 Intel740 IntelDX2 IntelDX4 IntelSX2 Intel Create amp Share Intel GigaBlade Intel InBusiness Intel Inside I
27. nday Friday 0800 1700 Malaysia time For IJKK Return Material Authorization RMA requests e mail address rma center jpss intel com Telephone No 81 298 47 0993 or 81 298 47 5417 Fax No 81 298 47 4264 Direct Return Authorization DRA for repair requests contact the JPSS Repair center E mail address sugiyamakx intel co jp Telephone No 81 298 47 8920 Fax No 81 298 47 5468 Office Hours Monday Friday 0830 1730 Japan time Intel NetStructure MPRTM4808 Rear Transition Board Installation Guide 31 Warranty Information ntel 32 If the Customer Support Group verifies that the product is defective they will have the Direct Return Authorization Return Material Authorization Department issue you a DRA RMA number to place on the outer package of the product Intel cannot accept any product without a DRA RMA number on the package Limitation of Liability and Remedies INTEL SHALL HAVE NO LIABILITY FOR ANY INDIRECT OR SPECULATIVE DAMAGES INCLUDING WITHOUT LIMITING THE FOREGOING CONSEQUENTIAL INCIDENTAL AND SPECIAL DAMAGES ARISING FROM THE USE OF OR INABILITY TO USE THIS PRODUCT WHETHER ARISING OUT OF CONTRACT NEGLIGENCE TORT OR UNDER ANY WARRANTY OR FOR INFRINGEMENT OF ANY OTHER PARTY S INTELLECTUAL PROPERTY RIGHTS IRRESPECTIVE OF WHETHER INTEL HAS ADVANCE NOTICE OF THE POSSIBILITY OF ANY SUCH DAMAGES INCLUDING BUT NOT LIMITED TO LOSS OF USE BUSINESS INTERRUPTIONS AND LOSS OF PROFITS NOTWITHSTANDING THE FO
28. nector pins are assigned Figure 19 USB Connector Pinout 1 1 2 Data 3 Data 4 GND 4 COM connector pins are assigned as shown below Figure 20 Connector Pinout RTS DTR TXD 1 GND RXD 8 DSR CTS 10o01 24 Intel NetStructure MPRTM4808 Rear Transition Board Installation Guide intel Figure 21 3 7 4 Figure 22 Installation The translation between the DB 9 and RJ 45 connectors is Ilustrated in the following diagram DBO9 to RJ 45 Translation 1 8 Male RJ 45 connector Pin 12345678 Pin 86215347 5 1 Female DB 9 connector 9 6 Reset Key The Intel 4808 board provides a reset key the front panel to execute a reset on the Intel NetStructure MPCBL5525 System Master Board in systems where the back can be accessed more easily than the front The way the reset is performed can be determined by adapting the settings in the Reset Control registers of the CPU board or by changing the settings of the switches on the CPU board A reset on the CPU board has no consequence for the Intel MPRTM4808 board Reset Key N o Intel NetStructure MPRTM4808 Rear Transition Board Installation Guide 25 Agency Approvals ntel Agency Approvals 4 4 1 4 2 4 3 4 3 1 26 CE Certification The Intel NetStructure 4808 Rear Transition Board meets intent of Directive 89
29. nsition Board Installation Guide ntel amp Installation 3 4 Switch Settings Caution Intel 4808 board provides two on board switches and one FP reset switch The switches must be set to OFF to avoid damage to attached PMC modules Figure 10 Location of Switches SW3 LE 12 SW2 ey LE 12 Table 3 Switch Settings Switch No Description SW2 1 ON Reset disabled ON OFF RESET enabled default i I 2 Reserved must be OFF default SW3 1 ON Flash disk is master ON OFF Flash disk is slave default I 2 Reserved must be OFF default 3 5 Installing and Removing the Board Caution To prevent board damange install and use the Intel MPRTM4808 board only with CPU boards especially designed for it Always turn off system power before installation or removal of the Intel MPRTM4808 board Use only the backplane s rear slot position Intel NetStructure MPRTM4808 Rear Transition Board Installation Guide 17 Installation intel Before touching integrated circuits make sure that you are working in an ESD safe environment When plugging the board in or removing it use the handles do not press on the front panel 3 5 1 Installation Procedure Note Connect interface cables to the on board connectors first since it may be difficult to reach them when the Intel MPRTM4808 board is already installed into the CompactPCI backplane Connect
30. ntel Inside logo Intel NetBurst Intel NetMerge Intel NetStructure Intel Play Intel Play logo Intel SingleDriver Intel SpeedStep Intel StrataFlash Intel TeamStation Intel Xeon Intel XScale IPLink Itanium MCS MMX MMX logo Optimizer logo OverDrive Paragon PC Dads PC Parents PDCharm Pentium Pentium II Xeon Pentium 111 Xeon Performance at Your Command RemoteExpress SmartDie Solutions960 Sound Mark StorageExpress The Computer Inside The Journey Inside TokenExpress VoiceBrick VTune and Xircom are trademarks or registered trademarks of Intel Corporation or its subsidiaries in the United States and other countries Other names and brands may be claimed as the property of others Copyright 2004 Intel Corporation All rights reserved 2 Intel NetStructure MPRTM4808 Rear Transition Board Installation Guide intel Contents 1 USING ThS HE 1 4 Terms and Definitions uuu U uu UU u 1 2 Other Sources of Information 2 Operating Safety L na 2 1 Electromagnetic Compatibility 2 2 Switch Settings a at e ento era diee doe akaqa aha qasqa 2 3 instalation nna De eR dex MEE CUM 2 5 Replacement Expansion sss 26 45 utro et e a ed a a 2 Environment fe n n aed t 3 CUENTE 3 1 2616
31. quirements are met Please refer to the product data sheet for airflow requirements if you are installing components in custom chassis Microprocessor Heatsinks May Become Hot During Normal Operation To avoid burns do not allow anything to touch processor heatsinks Do Not Operate Without Covers To avoid electric shock or fire hazard do not operate this product with any removed enclosure covers or panels To Avoid the Risk of Electric Shock Do not operate in wet damp or condensing conditions Do Not Operate in an Explosive Atmosphere To avoid injury fire hazard or explosion do not operate this product in an explosive atmosphere If Your System Has Multiple Power Supply Sources Disconnect all external power connections before servicing Power Supplies Must Be Replaced by Qualified Service Personnel Only Lithium Batteries Are Not Field Replaceable Units There is a danger of explosion if a battery is incorrectly replaced or handled Do not disassemble or recharge the battery Do not dispose of the battery in fire When the battery is replaced the same type or an equivalent type recommended by the manufacturer must be used Used batteries must be disposed of according to the manufacturer s instructions Return the unit to Intel for battery service Intel NetStructure MPRTM4808 Rear Transition Board Installation Guide Warning 4 7 Caution Agency Approvals AC and or DC Power Safety Warning AC and or DC Powered Un
32. rm Management Bus 1 IPMB1 and Intelligent Chassis Management Bus ICMB connectors Figure 1 Location of IPMB1 and ICMB Connectors 0 oc Uzo A 76 ze O gt RESET Check that the items listed were shipped together with the accessory kit Intel NetStructurerM 4808 Rear Transition Board nstallation Guide If delivered as part of a system design the Intel MPRTMASOS board is already installed in the system For information on system connectors available for user defined system configuration refer to the respective system s guide The cabling of all other connectors of the Intel MPRTM4808 board must remain as configured at system delivery 10 Intel NetStructure MPRTM4808 Rear Transition Board Installation Guide intel 3 2 Table 2 3 3 Figure 2 Installation Standard Compliances The Intel 4808 board meets the following standards Standard Compliances Standard Description EN 60950 Legal safety requirements UL cUL 1950 9 y req EN 55022 EN PODES EMC requirements on system level FCC Part 15 Class A ANSI IPC A 610 Rev C Class 2 12 Manufacturing standards ANSI J 001 003 On Board Connectors The Intel MPRTM4808 board provides the following on board connectors On Board Connectors PMC 1 I O PMC 2 I O Compact Flash Disk Floppy Disk Intel NetStructure MPRTM4808 Rear Transition Board Installation Guide 11
33. y contain fully tested recycled parts warranted as if new Returning a Defective Product RMA Before returning any product contact an Intel Customer Support Group to obtain either a Direct Return Authorization DRA or Return Material Authorization RMA Return Material Authorizations are only available for products purchased within 30 days Return contact information by geography Intel NetStructure MPRTM4808 Rear Transition Board Installation Guide Intel 5 1 1 1 5 1 1 2 5 1 1 3 5 1 1 4 Warranty Information For the Americas Return Material Authorization RMA credit requests e mail address requests rma intel com Direct Return Authorization DRA repair requests e mail address uspss repair intel com DRA on line form http support intel com support motherboards draform htm Intel Business Link IBL www intel com ibl Telephone No 1 800 INTELAU or 480 554 4904 Office Hours Monday Friday 0700 1700 MST Winter PST Summer For EMEA Return Material Authorization RMA e mail address emea fs intel com Direct Return Authorization DRA for repair requests e mail address emea fs intel com Intel Business Link IBL http intel com ibl Telephone No 00 44 1793 403063 Fax No 00 44 1793 403109 Office Hours Monday Friday 0900 1700 UK time For APAC RMA DRA requests email address apac rma front end intel com Telephone No 604 859 3111 or 604 859 3325 Fax No 604 859 3324 Office Hours Mo
Download Pdf Manuals
Related Search
Related Contents
化学物質管理基準 - 京セラドキュメントソリューションズ Lava Parallel-PCIe/LP 取付説明書 - TOEX George Foreman GR2080B Use & Care Manual servervalencia\\company\\Ingenieria\\Doc_Tecnica\\E_ electrónica Manual de Instrucciones Bissell 7950 Vacuum Cleaner User Manual Copyright © All rights reserved.
Failed to retrieve file