Imation Door CK 108 User's Manual

image

Contents

1. 05 TO PROGRAM TIME IN MINUTES 1 TO 60 05 15 TO PROGRAM TIME IN TENTHS OF SECONDS 1 60 USE 25 TO PROGRAM TIME IN TEN S OF SECONDS 1 60 USE 35 EXAMPLE YOU WISH TO PROGRAM THE LOCK RELEASE TO OPERATE 2 MINUTES AFTER THE CORRECT CODE 15 ENTERED 1 SLIDE SWITCH TO P 2 TYPE ONTO KEYPAD 15 2 3 SLIDE SWITCH TO N Page 5 ALARM DURATION THIS IS THE TIME FOR WHICH AN ALARM WILL OPERATE THIS FUNCTION 18 PRO GRAMMED SEPARATELY FOR EACH DOOR BY USING ITS RESPECTIVE KEYPAD TAKE NOTE WHILST THE ALARM IS OPERATING ALL OTHER FUNCTIONS ARE INOPERATIVE FACTORY CODE SET AT 30 SECONDS TO PROGRAM TIME IN SECONDS 1 60 USE 04 PROGRAM TIME IN MINUTES 1 60 USE 14 PROGRAM TIME IN TENTHS OF SECONDS 1 60 USE 24 TO PROGRAM TIME IN TEN S OF SECONDS 1 60 USE 34 EXAMPLE YOU WISH THE ALARM TO OPERATE FOR 25 SECONDS 1 SLIDE SWITCH P 2 TYPE ONTO KEYPAD 04 25 3 SLIDE SWITCH BACK TO N NOTE THE ALARM OUTPUTS CAN DRIVE ANY DEVICE SUCH AS AN ELECTRONIC TONE OR RELAY AS LONG AS THEY DO NOT EXCEED 0 5 AMP IN THE EVENT THAT A HIGHER CURRENT DEVICE IS REQUIRED PLEASE USE AN ISOLATING RELAY WHEN THE ALARM IS ON THE LOCK RELEASE WILL NOT OPERATE SHO
2. KEYPADA 0 ALARM ALARM A Page 11 NORMALLY OPEN CONTACTS TO OPERATE LOCK RELEASE VIA DOOR ENTRY SYSTEM OR ANY OTHER DEVICE WHICH REQUIRES MORE THAN 0 5 AMP EH EASE ES EAC EEE ECE REMOTE SWITCH FOR OPERATING LOCK RELEASE DIRECTLY IF REQUIRED MODEL 84 RELAY MUST BE INSTALLED NO CLOSER THAN 1 METRE FROM THE CONTROL UNIT Page 12
3. CONTENTS PAGE INTRODUCTION EE yee 1 SPECIFICATION 3 sxc was 1 INSTALLATION 6 2 TROUBLE SHOGTING 2 BENGH TESTING 3 FACTORY GODDESS Wied oe tas A 3 SECOND CODE 6 1247 bk Be 3 PROGRAMMING CODE aati Ree 4 PROGRAMMING CODE 2 dan cg Gab Gale decide als 4 LOGK DURATION See sues 5 LOCK 5 ALARM BUBAFION canes Ae 6 FALSE CODE ALARM eee eee eee RS 6 KEYING TIME LIMIT SG KOA eae seed 7 ae 7 ACTION CODES aes 8 ACTION CODE 22555255020 9 WIRING DIAGRAM FOR 10 WIRING DIAGRAM FOR 14 WIRING DIAGRAM FOR DOOR ENTRY SYSTEM AND LOCK RELEASE OVERRIDE 12 MODEL 108 CODED LOCK WE ARE PLEASED THAT YOU CHOSE OUR PRODUCT FOR YOUR REQUIREMENT AND WE HOPE THAT WITHIN THE NEXT FEW PAGES YOU WILL HAVE GAINED ALL NECESSARY EXPERTISE TO PROGRAM OUR MODEL 108 CODED LOCK FIRST HOWEVER MAY WE MENTION FEW POINTS THAT MAKE THE
4. A DOOR ENTRY TELEPHONE SYSTEM AN ISOLATING RELAY MUST BE USED WARNING DO NOT APPLY ANY OTHER VOLTAGE TO THE LOCK AND ALARM OUTPUT THIS WOULD DAMAGE THE UNIT TROUBLE SHOOTING NOTHING OPERATES BEFORE CODING 1 TEST POWER SUPPLY IT SHOULD READ 13 TO 15 VOLTS 2 CHECK KEYPAD WIRING 3 MAKE CERTAIN THAT THE PROGRAM SWITCH IS SET TO N 4 13 THE LOAD MORE THAN 0 5 IF YOU ARE NOT CERTAIN MEASURE THE RESISTANCE OF THE COIL IT SHOULD BE ABOVE 28 OHMS 5 CHECK CONNECTIONS TO THE KEYPAD 6 INITIALLY THE FACTORY CODE SHOULD OPERATE IT S 12345 7 ARE YOU USING KEYPAD A AND LOCK RELEASE A NOTHING OPERATES AFTER CODING IF THE FACTORY CODE OPERATED BEFORE YOU CODED PLEASE READ INSTRUCTIONS AGAIN BE CAREFUL WHEN ENTERING CODES REMEMBER TO SLIDE PROGRAMMING SWITCH BACK TO N AFTER CODING IT IS POSSIBLE TO PROGRAM OTHER FUNCTIONS ACCIDENTALLY WHILST PROGRAMMING A CHANGE OF CODE THIS COULD STOP THE UNIT FROM FUNCTIONING Page 2 BENCH TESTING IN THE EVENT THAT YOU ARE TESTING THE UNIT ON THE BENCH AND THE KEYPAD IS CONNECTED A SHORT DISTANCE FROM THE UNIT YOU MUST ALLOW A MINIMUM TIME OF TWO SECONDS TO ELAPSE BEFORE SLIDING THE PROGRAMMING SWITCH BACK TO N AFTER KEYING IN THE CODE THIS TIME IS REQUIRED FOR THE UNIT TO STORE THE NEW SOFTWARE IMPORTANT THIS UNIT CAN BE DAMAGED IF A DOOR ENTRY SYSTEM IS INSTALLED USING THE SAME LOCK RELEASE AND A FOREIGN VOLTAGE IS APPLIED TO THE
5. LOCK RELEASE OUTPUT YOU MUST USE AN ISOLATING RELAY FACTORY CODE IN THE EVENT THAT NOTHING WORKS YOU MUST REPROGRAM THE FACTORY CODE 1 SLIDE SWITCH TO P 2 KEY ONTO THE KEYPAD THE FOLLOWING 09 3 SLIDE THE SWITCH BACK TO N SECOND CODE DO NOT CONFUSE THE SECOND CODE WITH THE SECOND DOOR EACH DOOR THIS IS THE KEYPAD WITH ITS ASSOCIATED LOCK RELEASE HAS TWO CODES AVAILABLE IF YOU ARE REQUIRED TO PROGRAM A SECOND DOOR THAT IS A SECOND KEYPAD WITH ITS ASSOCIATED LOCK RELEASE THE INSTRUCTIONS ARE AS FOR THE FIRST DOOR THE USE OF THE SECOND KEYPAD S SUFFICIENT TO INSTRUCT THE UNIT THAT YOU ARE PROGRAMMING THE SECOND DOOR THE SECOND CODE REQUIRES THE CONTACTS TC TO BE SHORTED OUT FOR THE CODE TO OPERATE Page 3 PROGRAMMING CODE NO 1 THIS FUNCTION WILL PROGRAM THE UNIT WITH A NEW CODE ANY NUMBER UP TO 8 DIGITS MAY BE USED FOR THIS CODE THIS FUNCTION 18 PROGRAMMED SEPARATELY FOR EACH DOOR BY USING ITS RESPECTIVE KEYPAD FACTORY CODE SET AT 12345 TO PROGRAM CODE NO 1 965 01 EXAMPLE YOU WISH CHANGE THE CODE 222560 1 SLIDE PROGRAMMING SWITCH ON THE PRINTED CIRCUIT BOARD TO P 2 TYPE ONTO THE KEYPAD 01 222560 3 SLIDE PROGRAMMING SWITCH ON THE PRINTED CIRCUIT BOARD BACK PROGRAMMING CODE NO 2 THIS FUNCTION WILL PROGRAM THE UNIT WITH A NEW SECOND CODE ANY NUMBER UP TO 8 DIGITS MAY BE USED FOR THIS CODE THIS FUNCTION 1
6. MODEL 108 UNIQUE AND IN OUR OPINION THE MOST ADVANCED CODED LOCK AVAILABLE TO DATE ALL FUNCTIONS ARE USER PROGRAMMABLE THE MEMORY IS NON VOLATILE IT DOES NOT DEPEND ON A BATTERY THE UNIT INCORPORATES A MASKED MICROCOMPUTER PURPOSE DESIGNED FOR THE SECURITY INDUSTRY IF AND WHEN THE COMPUTER CRASHES WILL AUTOMATICALLY RESET WITHIN AVERAGE TIME OF 10 MILLISECONDS WITHOUT LOSING ANY STORED DATA PLEASE READ INSTALLATION INSTRUCTIONS BEFORE INSTALLING SPECIFICATION INPUT VOLTAGE 12 VOLTS NOMINAL DC AT 1 AMP QUIESCIENT CURRENT 0 2 AMP 4 OUTPUTS 2FOR LOCK RELEASES MAXIMUM 05 EACH 2 FOR ALARM CIRCUITS MAXIMUM 0 5 AMP EACH 3 INPUTS 2 FOR KEYPADS 7 WIRES EACH 1 FOR EXTERIOR SWITCH TIME CLOCK CARD READER ETC THIS MANUAL IS TO BE LEFT WITH THE USER Page 1 INSTALLATION INSTRUCTIONS A LOCK RELEASE OR ANY OTHER DEVICE WHICH IS TO BE DRIVEN DIRECTLY BY THE UNIT MUST NOT EXCEED 0 5 AMP FOR RELIABLE OPERATION THE SOFTWARE WITHIN THE MICROPROCESSOR WILL INSTANTLY DETECT AN OVERLOAD AND SWITCH OFF BEFORE ANY DAMAGE CAN BE DONE IT WILL APPEAR AS IF THE UNIT IS NOT WORKING FOR THAT REASON A FILAMENT BULB CANNOT BE USED FOR TESTING THE UNIT AS WHEN THE BULB IS COLD IT INITIALLY DRAWS MORE THAN 0 5 AMP IF 11 REQUIRED THAT YOU DRIVE A DEVICE WHICH IS MORE THAN 0 5 AMP AN ISOLATING RELAY MUST BE USED IMPORTANT IN THE EVENT THAT THE LOCK RELEASE IS ALSO USED BY ANOTHER SYSTEM SUCH AS
7. PROGRAMMED SEPARATELY FOR EACH DOOR BY USING ITS RESPECTIVE KEYPAD NOTE THIS CODE WILL ONLY OPERATE WHEN TERMINALS TC ARE SHORTED OUT BY A WIRE LINK OR CONTACTS FROM A TIME CLOCK ETC FACTORY CODE SET AT 67890 TO PROGRAM CODE NO 2USE is sS neste cece 02 EXAMPLE YOU WISH CHANGE THE CODE 802 1 SLIDE SWITCH 2 TYPE ONTO THE KEYPAD 02 802 3 SLIDE SWITCH BACK TO N Page 4 LOCK DURATION THIS IS THE TIME FOR WHICH THE LOCK WILL OPERATE AFTER THE CORRECT CODE HAS BEEN ENTERED THIS FUNCTION IS PROGRAMMED SEPARATELY FOR EACH DOOR BY USING ITS RESPECTIVE KEYPAD FACTORY CODE SET AT 3 SECONDS TO PROGRAM THE TIME IN SECONDS 1 60 USE 03 PROGRAM THE TIME IN MINUTES 1 60 USE 13 PROGRAM THE TIME IN TENTHS OF SECONDS 1 60 USE 23 TO PROGRAM THE OF SECONDS 1 60 USE 33 EXAMPLE YOU WISH THE LOCK RELEASE OPERATE FOR 9 SECONDS 1 SLIDE SWITCH TO P 2 TYPE ONTO KEYPAD 03 9 3 SLIDE SWITCH TO N LOCK DELAY THIS IS THE TIME WHICH WILL ELAPSE BETWEEN THE CORRECT CODE BEING ENTERED AND LOCK RELEASE OPERATING THIS FUNCTION 1 PROGRAMMED SEPARATELY FOR EACH DOOR BY USING ITS RESPECTIVE KEYPAD FACTORY CODE SET AT 0 TO PROGRAM TIME IN SECONDS 1 60 USE
8. KEYPADS TWO ACTION CODES MUST ALWAYS BE PROGRAMMED TOGETHER AT ANY ONE TIME FOR CODE 1 AND CODE 2 TO PROGRAM ACTION CODES 1 SLIDE SWITCH P 2 TYPE ONTO KEYPAD 00 ONE DIGIT FOR CODE 1 ONE DIGIT FOR CODE 2 3 SLIDE SWITCH BACK TO N TABLE LOCK NOT ABLE TO OPERATE LOCK ABLE TO OPERATE LOCK ABLE TO OPERATE ONLY IF CONTACTS ARE CLOSED LOCK ABLE TO OPERATE ONLY IF THE CONTACTS ARE OPEN ALARM ABLE TO OPERATE ALARM ABLE TO OPERATE ONLY IF THE CONTACTS ARE CLOSED ALARM ABLE TO OPERATE ONLY IF THE CONTACTS ARE OPEN DURESS ABLE TO OPERATE DURESS ABLE TO OPERATE ONLY IF THE CONTACTS ARE CLOSED DURESS ABLE TO OPERATE ONLY IF THE CONTACTS ARE OPEN FACTORY CODE SET 12 THAT IS THE FIRST CODE WILL ALWAYS OPERATE AND THE SECOND CODE WILL OPERATE ONLY IF THE TC TERMINALS ARE SHORTED OUT ACTION CODE EXAMPLES ONE CODE ONLY YOU REQUIRE THE FIRST CODE TO OPERATE NORMALLY AND THE SECOND CODE NEVER TO OPERATE KEY IN THE FOLLOWING AFTER SWITCHING P 00 10 THEN SWITCH Page 8 SECOND CODE OPERATES WITH CONTACTS OPEN YOU REQUIRE THE 1ST CODE TO OPERATE NORMALLY AND THE 2ND CODE TO OPERATE ONLY WHEN THE TC CONTACTS ARE OPEN KEY IN THE FOLLOWING AFTER SWITCHING TO P 00 13 THEN SWITCH ONE CODE AT A TIME BOTH CODES ARE REQUIRED BUT NOT AT THE SAME TIME THE TC CONTACT HAS TO BE USED TO PROGRAM THIS FUNCTION THE FIRST CODE I
9. NDS 1 60 USE 07 PROGRAM TIME MINUTES 1 60 USE 17 TO PROGRAM TIME IN TENTHS OF SECONDS 1 60 USE 27 TO PROGRAM TIME OF SECONDS 1 60 USE 37 EXAMPLE YOU WISH TO LIMIT THE TIME AVAILABLE BETWEEN ENTRIES 5 SECONDS 1 SLIDE SWITCH TO 2 TYPE ONTO KEYPAD 07 5 3 SLIDE SWITCH BACK TO N TO DISABLE THIS FUNCTION 1 SLIDE SWITCH TO P 2 TYPE ONTO KEYPAD 07 0 3 SLIDE SWITCH BACK TO N CAUTION IF KEYING TIME AND FALSE CODE TIME ARE DISABLED THE SITUATION COULD ARISE WHEREAS MOST OF THE CORRECT CODE IS ENTERED AND LEFT IT WOULD THEN ONLY NEED THE LAST MISSING DIGIT S TO OPERATE THE LOCK KEY LIMIT THIS FUNCTION LIMITS THE NUMBER OF DIGITS WHICH CAN BE ENTERED AT ANY ONE TIME BEFORE TRIGGERING AN ALARM THIS FUNCTION IS PROGRAMMED SEPARATELY FOR EACH DOOR USING IT S RESPECTIVE KEYPAD FACTORY CODE SET AT 15 TO PROGRAM KEY LIMIT 1 99 8 08 EXAMPLE YOU WISH TO LIMIT KEY ENTRIES 10 1 SLIDE SWITCH 2 TYPE ONTO KEYPAD 08 10 3 SLIDE SWITCH BACK TO N Page 7 ACTION CODES THESE CODES DETERMINE THE ACTION THAT OCCURS WHEN A VALID CODE HAS BEEN ENTERED THEY CONTROL THE LOCK AND ALARM OUTPUTS THE ACTION CODES ARE PROGRAMMED SEPARATELY FOR EACH DOOR BY USING THE RESPECTIVE
10. S OPERATIONAL WHEN THE CONTACTS ARE OPEN ONLY THE SECOND CODE 1 OPERATIONAL WHEN THE CONTACTS ARE CLOSED ONLY KEY IN THE FOLLOWING AFTER SWITCHING TO P 00 32 THEN SWITCH DURESS CODES A YOU REQUIRE THE FIRST CODE TO OPERATE NORMALLY THE SECOND CODE TO OPERATE THE LOCK RELEASE AND THEN OPERATE AN ALARM KEY IN THE FOLLOWING AFTER SWITCHING P 00 17 THEN SWITCH TO B YOU REQUIRE THE FIRST CODE TO OPERATE NORMALLY THE SECOND CODE TO OPERATE A LOCK RELEASE AND THEN OPERATE AN ALARM IF THE TC CONTACTS ARE CLOSED KEY IN THE FOLLOWING AFTER SWITCHING TO P 00 18 THEN SWITCH N C YOU REQUIRE THE FIRST CODE TO OPERATE NORMALLY THE SECOND CODE TO OPERATE AN ALARM ONLY KEY IN THE FOLLOWING AFTER SWITCHING TO 00 14 THEN SWITCH TO PLEASE NOTE IN THE EVENT THAT YOU WERE NOT SUCCESSFUL IN PROGRAMMING YOUR DESIRED FUNCTION THE FIRST TIME IT IS ADVISABLE TO GO BACK TO THE FACTORY CODE BEFORE REPROGRAMMING FACTORY CODE 09 Page 9 SUPPLY 12 KEY SWITCH TIME CLOCK OR CARDKEY READER LOCK RELEASE DOOR ALARM CIRCUITS DOOR A KEYPAD A ALARM A Page 10 POWER SUPPLY 12 DC KEY SWITCH TIME CLOCK OR CARDKEY READER ALARM CIRCUITS DOOR B LOCK RELEASE B KEYPAD B ee ee le
11. ULD YOU REQUIRE BOTH THE ALARM AND THE LOCK RELEASE TO OPERATE SUCH AS WITH A DURESS CODE PLEASE REFER TO THE ACTION CODES FALSE CODE ALARM THIS FUNCTION IMPOSES A TIME LIMIT FOR ENTERING THE CODE WHEN IN USE IT WILL TRIGGER AND ALARM IF A VALID CODE 1 NOT KEYED IN WITHIN THE SPECIFIED PERIOD THIS FUNCTION 18 PROGRAMMED SEPARATELY FOR EACH DOOR USING ITS RESPECTIVE KEYPAD FACTORY CODE SET AT 0 UNABLE TO OPERATE TO PROGRAM TIME IN SECONDS 1 TO 60 USE 06 TO PROGRAM TIME IN MINUTES 1 60 USE 16 PROGRAM TIME IN TENTHS OF SECONDS 1 60 USE 26 TO PROGRAM TIME IN TENS OF SECONDS 1 60 USE 36 EXAMPLE YOU WISH AN ALARM TO OPERATE IN THE EVENT THAT THE KEYPAD 1 USED BUT A CORRECT CODE HAS NOT BEEN ENTERED WITHIN 90 SECONDS 1 SLIDE SWITCH TO 2 TYPE ONTO KEYPAD 36x 9 3 SLIDE SWITCH BACK TO N Page 6 KEYING TIME LIMIT THIS FUNCTION IMPOSES A TIME LIMIT FOR MAKING AN ENTRY WHEN IN USE IT WILL AUTOMATICALLY CANCEL THE PRECEDING KEYPAD ENTRIES IF THE NEXT ENTRY 15 MADE WITHIN THE SPECIFIED TIME NO ALARM WILL BE TRIGGERED THIS FUNCTION 18 PROGRAMMED SEPARATELY FOR EACH DOOR BY USING ITS RESPECTIVE KEYPAD IMPORTANT NOTE THE USE OF A FALSE CODE ALARM WILL AUTOMATICALLY DISABLE THIS FUNCTION FACTORY CODE SET AT 10 SECONDS TO PROGRAM TIME IN SECO