1. 5 ICON IMAGE FORMULAIRE DE GARANTIE DU PRODUIT IMPORTANT POSTEZ DANS LES 14 JOURS SUIVANT L ACHAT NOM ADRESSE PAYS CODE POSTAL T L PHONE N DE MOD LE Ne DE SERIE DATE D ACHAT 1 NOM DU D TAILLANT ADRESSE 1 Usager principal du produit 8 Avez vous d j consid r l achat d un produit fabriqu par un Homme Femme Famille autre manufacturier n Jo L Non Oui 1 1 2 de l usager principal Si oui lequel Ci 0 24 35 44 0 55 64 eges Q 25 34 45 54 65 et plus 9 Bas sur votre impression du produit ach teriez vous un autre produit ICON 3 Revenu annuel J Oui ON as I C1 0 9 999 15 000 19 999 ut on ans opinion 1 10 000 14 999 20 0004 Sinon quelle marque ach teriez vous 4 Combien de fois par semaine faites vous de l exercice 10 Poss dez vous d autre quipement d exercice moins que 3 fois 3 fois et plus Bicyclette L Bicyclette stationnaire Tapis 5 Avez vous d ja achet un produit L Appareil de musculation L1 Banc d exercice I Q Oui Non 1 Simulateur d escalier L Cardio Glide Autre 1 6 parler des 11 Quel type de magazine lisez vous r guli rement Sports 0 G n ral 1 Automobilisme Magazine Ami Parent Autre Affaires Ordinateur Mise 1
2. DANGER To reduce the risk of drowning Prolonged immersion in the RENEW 900 may cause hyperthermia a dangerous condition which occurs when the internal body temper ature rises several degrees above the normal body temperature of 98 6 F The symptoms of hyperthermia are nausea dizziness drowsi ness and fainting Effects include a lack of awareness inability to perceive heat or dan ger and a greater risk of drowning due to a loss of consciousness Special note Individuals suffering from hyperthermia may be unable to realize that they must exit the RENEW 900 and they also may be physically unable to do so WARNING To reduce the risk of drowning Heat from the water in conjunction with alco hol or drugs can cause unconsciousness Do not use the RENEW 900 if you are under the influence of drugs or alcohol WARNING To reduce the risk of injury or drowning Consult your physician about pos sible side effects of any medications you may be taking before using the RENEW 900 Heat from the water in conjunction with some med ications may cause drowsiness and increase the risk of drowning Others can effect blood pressure heart rate and circulation WARNING To reduce the risk of injury It is especially important for persons over the age of 35 or persons with pre existing health problems such as obesity heart disease high or low blood pressure circulatory prob lems or diabetes to consult your physician before usi
3. 1 7 Quel est votre raison principale pour avoir choisi un produit ICON n Employ du magasin Publicit la t l vision 12 D sirez vous recevoir de l information suppl mentaire sur les Options lectroniques Publicit dans un magazine produits ICON ON i I Mod le du produit Innovation du produit on I Couleur Q Prix LJ Autres aspects MERCI DE VOTRE TEMPS B Su Uu PART LIST Model No 831 100430 Key No Qty D BR BPA HR SH HS PO AH ms DD D RER RE Description Side Panel Power Cord Grommet Dual Temperature Probe Inflatable Cover Clamp Screw Clamp Bolt Fabric Spa Surround Inflatable Spa Liner Spa Jet Nozzle Spa Cover Heater O ring Spa Jet Unit Heater Housing Filter Cover Screw Filter Cover Screw Suction Cover Suction Fitting Pump Motor Heater Terminal Cover Heat Controller Heater Wire Harness Cover Nut Electronic Control Tri jet Nozzle Headrest w Fasteners Nut Heat Control Nut Rubber Insulator Washer Whirlpool Jet Key No Qty 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 oL arg ND R0499A Description Rubber Damper Wire Harness Air Control Kno
4. 1 6 Where did you first see or hear about ICON products 11 Which type of magazines do you read regularly Magazine Q Friend relative Sports Q Fitness C Motoring Newspaper Ad Store Business Computer General Other 12 Do you wish to be sent further bulletins about ICON products 1 7 What was the primary reason for purchasing this ICON product LI Yes No l L Store Employee L Television Ads Colour 1 1 Electronic Features Magazine Ads Price THANK YOU FOR YOUR TIME 1 d Product Design J Product Innovation I Other Features 1999 ICON of Canada Inc Printed in USA L REFERENCES N du Mod le N de S rie Nom du D taillant 1 Date d Achat Adresse du D taillant AFFRANCHIR SUFFISAMMENT ICON of du Canada Inc 900 de l Industrie St J r me Qu bec Canada J7Y 4B8 18 GARANTIE LIMITEE DE ANS ICON du CANADA Inc ICON garantie que ce produit n a aucun d faut de fabrication ou de mat riaux sous utilisation et main tenance normale pour une p riode de quatre vingt dix 90 jours apr s la date d achat de ce produit ICON rallonge une garantie limit e pendant cing 5 ans sur la structure du jacuzzi ICON rallonge aussi une garantie limit e de deux 2 ans pour la pompe et le moteur Cette garantie est rallong e seulement pour l acheteur original L obligation d ICON sous cette garantie est limit e au
5. The chemicals used to maintain the pH balance of the water and to sanitize the water can be dangerous Always follow these basic guide lines when handling the chemicals 1 Always read and follow the directions on the label unless directed otherwise Never mix different chemicals Do not exceed the recommended amounts follow the directions on the label closely 2 3 13 4 Keep all chemicals out of the reach of chil dren and pets 5 Keep all containers closed tightly when not in use 6 Never add water to the chemicals always add the chemicals to the water as directed 7 Always store chemicals in a cool dry place 8 Always keep chemicals away from chil dren and pets MAINTAINING THE PROPER PH BALANCE The pH factor is a measure of relative acidity or alka linity in the water It is measured on a scale of 1 to 14 Pure water has a value of 7 which is neutral Any value above 7 is alkaline and any value below 7 is acidic You should maintain a slightly alkaline pH level between 7 2 and 7 8 in the RENEW 900 Severe problems can occur when the pH balance is not maintained within this range If the pH level exceeds 7 8 dissolved minerals can build up and clog the plumbing in the spa jet unit If the pH level falls below 7 2 the acid level in the water will begin to cor rode the metal parts in the spa jet unit Also the sani tation agents in the water will not be effective if the pH level is not properly ma
6. always be clean and dry before being moved or stored CHECKING AND CLEANING THE FILTER The filter should be checked periodically for build up of dirt and oil If the filter needs to be cleaned follow the steps below 1 Turn off the power 2 Remove the two screws and cover from the spa jet Then pull the filter out of the unit Check the filter for any dirt or debris If the fil ter needs to be cleaned rinse the filter with a hose If the filter still is dirty you will need to soak it in a cleaning solution which can be obtained from a pool and spa supply store Inspect the filter for damage Replace the fil ter if there are any signs of damage Re insert the cleaned filter and re attach the two screws and cover to the spa jet unit 3 MAINTAINING THE SPA COVER The spa cover should be cleaned monthly Remove the inflatable cover from the spa cover then hang the spa cover over a clothes line and spray it with a hose Leave the cover on the clothes line until it is fully dry WINTER USE AND CARE The RENEW 900 is designed for year round use If you decide to store the RENEW 900 for the winter store it in a warm dry location See DRAINING THE RENEW 900 and DRAINING THE PUMP on page 12 WATER CHEMISTRY The RENEW 900 comes with a starter chemical pack for maintaining the water in the spa See TESTING AND TREATING THE WATER on page 10 Additional chemicals can be purchased at a pool and spa supply store CAUTION
7. celles sp cifiquement mentionn es ci dessus ICON ne pourra tre tenu responsable d aucun dommage indirect sp cial ou accessoire r sultant ou ayant trait l utilisation ou au fonctionnement du produit aux pertes d argent de biens de revenus ou de profits aux pertes de jouissance aux frais de d m nagement d installation ou tous dommages accessoires de quelque nature qu ils soient Dans certaines provinces il est interdit d exclure ou de restreindre la responsabilit pour les dommages indirects ou accessoires de sorte que la restriction qui pr c de pourrait ne pas s appliquer dans certains cas La pr sente garantie remplace toutes les garanties dont notamment les garanties implicites de valeur marchande ou d aptitude un usage et est limit e dans sa dur e et sa port e par les clauses sp cifiques contenues dans la pr sente garantie Certaines provinces n autorisent pas la restriction de la dur e d une garantie de sorte que la restriction qui pr c de pourrait ne pas s appli quer dans certains cas ou sp cifi s par votre d taillant d quipement de sports Cette garantie vous conf re des droits l gaux sp cifiques Vous pouvez avoir d autres droits qui peuvent varier d une province l autre ou sp cifier par votre d taillant d quipement de sports ICON OF DU CANADA INC 900 de l Industrie St J r me QC J7Y 4B8 tat osha a ea aa meme 1
8. if it is dirty b Check the chemical balance of the water If the is incorrect the sanitizing agents will not function properly 10 SYMPTOM THE SPA JET UNIT CONTINUES TO RUN AFTER IT HAS BEEN SHUT OFF a When you press the on off button once the spa jet unit will run at low speed heating the water Press the button again and the spa jet unit will run at high speed filtering the water Press the button a third time and the spa jet unit will shut off The spa jet unit also features an automatic mode which heats and filters the water when the spa is left unattended When the spa jet unit is first plugged in or if the buttons on the console have not been used for longer than twenty minutes the automatic mode will begin filtering or heating the water as needed To keep the filter and heat cycles from running the power cord must be unplugged Special Note If the unit is to be kept outdoors in cold weather you must allow the spa to maintain a safe temperature by running in automatic mode Allowing the spa jet unit to freeze will damage the unit If you do not want to use the spa during the winter store it in a warm dry location see WINTER USE AND CARE on page 13 11 12 15 SYMPTOM THE WATER LEVEL DROPS a b Some water loss due to evaporation is normal If rapid water loss occurs or if you notice wet ness on the floor around the RENEW 900 then the liner may have a leak Locate the leak and
9. remplacement ou aux r parations au choix d ICON du produit par un des centres de service autoris s Toutes r parations qui sont soumises sous la garantie doivent tre pr approuv es par ICON Cette garantie ne comprend pas les dommages caus s ou dues au transport abus mauvais usage ou r parations faites par une personne non autoris e par ICON aux pro duits utilis s pour une utilisation commerciale ou pour la location ou aux produits utilis s pour l exposition en magasin Les dom mages caus s ou attribu s aux incidents suivants sont exclus de la garantie les dommages faits au bois du jacuzzi caus s par un mauvais entretien ou tout dommage fait au bois ou aux panneaux ext rieurs caus s par un mauvais transport les dommages caus s par le froid la pluie ou le gel les dommages faits la structure du jacuzzi dues un mauvais usage des produits chim iques des temp ratures extr mes ou une exposition prolong e aux rayons directes du soleil et des ultra violet quand le jacuzzi est vide les dommages la pompe au moteur la canalisation et aux pi ces dues un mauvais entretien aux produits chimiques ou l exposition les dommages r sultants de ne pas lire les instructions d assemblage et de fonctionnement con tenus dans le livret d instructions Les pi ces usables sont aussi exclus telles que mais non restrict es appui t te cartouch es du filtre et ampoules ICON n autorise aucune autre garantie part
10. repaired or replaced by a qualified electrician STARTING THE RENEW 900 Once you have tested the GFCI you should verify the water flow from the pumping unit Set the air control on the console to the lowest setting see USING THE CONSOLE on the next page The pumping unit will heat the water as it pumps Cover the RENEW 900 with the spa cover The spa cover must be tight The water will heat at about 1 7 F an hour with the cover on If you are using the RENEW 900 indoors and the room temperature is maintained at 70 F it will take approximately 20 to 28 hours for the water to reach the set temperature The temperature and water flow can be set or changed by the controls on the console see USING THE CONSOLE on the next page TESTING AND TREATING THE WATER The RENEW 900 comes with a starter chemical pack for maintaining the water in the spa Disregard the directions on the individual packages of QUICK pHix It DOWN and QUICK pHix It UP However the directions on the bottle of Non chlorine Shox and Bromine Base are correct Always keep the chemi cals away from children and pets The first time you use the spa you should test and treat the water Once you have verified that the spa jet unit is functioning properly and have allowed the water to circulate for a while you should remove the spa cover and add 1 3 of the Bromine Base bottle and 1 3 of the Non chlorine Shox bottle to the water in the spa Allow the
11. Model No 831 100430 Serial No Write the serial number in the space above for reference Serial Number Decal QUESTIONS As a manufacturer we are com mitted to providing complete customer satisfaction If you have questions or find that there are missing or damaged parts we will guarantee complete satis faction through direct assistance from our factory TO AVOID UNNECESSARY DELAYS PLEASE CALL DIRECT TO OUR TOLL FREE CUSTOMER HOT LINE The trained techni cians on our customer hot line will provide immediate assis tance free of charge to you CUSTOMER HOT LINE 1 888 936 4266 Mon Thu 8 00 am 6 30 pm Fri 8 00 am 6 00 pm EST CAUTION Read all precautions and instruc tions in this manual before using this equipment Save this manual for future reference Patent Pending USER S MANUAL SEARS CANADA INC TORONTO ONTARIO M5B 2B8 TABLE OF CONTENTS IMPORTANT SAFETY INSTRUCTIONS 3 WARNING DECAL PLACEMENT 5 BEFORE YOU BEGIN e Eres nr s ette Od aed hig 6 CHOOSING A LOCATION FOR THE RENEW 900 7 ASSEMBLY e ete ertt pde doe eo aye 8 USING THE RENEW 900 1 5 ddr rente Ri RR SERO REL RIS ER elite 10 MAINTENANCE 5 ke hes des ub Ee eden Mae es d USER RR Ye PER RS 13 TROUBLESHOOTING n
12. RENEW 900 These factors vary depending on whether you use the RENEW 900 inside or outside We have listed several factors you may wish to consider as you decide where you want to use the RENEW 900 If you set up the RENEW 900 inside 1 The RENEW 900 will increase the level of humidi ty in your home The location you choose should be well ventilated You may need to install a venti lation fan or use a dehumidifier The location must be close to an electrical outlet Do not use an extension cord with the RENEW 900 The RENEW 900 should be close to a source of water Do not use the RENEW 900 on carpet or other material that may be damaged by moisture We recommend that you place the RENEW 900 on a water and stain resistant non slip surface with a floor drain for any water that may splash from the RENEW 900 Be sure that the location you choose is stable It must be able to support the weight of the RENEW 900 when it is filled with water plus the weight of the occupants The RENEW 900 weighs approxi mately 2400 pounds when filled with water Do not use the RENEW 900 above a finished liv ing area due to the risk of water damage Be sure that there is room around the RENEW 900 to permit servicing of the unit The diameter of the tub is 69 You should allow for this size plus the size of the spa jet unit when choosing the location Be sure to note any other considerations such as aesthetic
13. ST excluding holi days 1 SYMPTOM THE SPA WILL NOT OPERATE a Check the power cord The power cord must be plugged into a grounded outlet see PLUG GING IN THE RENEW 900 on page 10 b Check to see if the GFCI breaker is tripped or was not turned on Reset the GFCI breaker SYMPTOM THE CIRCUIT BREAKER OR BREAKER TRIPS WHILE THE SPA IS OPERATING a Reset the circuit breaker If the circuit breaker trips again contact a qualified electrician for service SYMPTOM THE PUMP HUMS a The filter may be dirty or damaged Remove the filter housing from the spa jet unit and clean or replace the filter b The pump may have a foreign object stuck in the impeller Contact our customer service department c The pump may have a loose wire connection Contact our customer service department SYMPTOM THE PUMP HUMS BUT DOES NOT ROTATE a The pump may be jammed Contact our cus tomer service department SYMPTOM THE PUMP IS NOISY WHILE OPERATING a There may be debris in the pump Contact our customer service department b The pump may have a bad bearing Contact our customer service department SYMPTOM THE WATER DOES NOT HEAT a The heater is attached to the pump in the spa jet unit If the pump is operating the water should heat Cover the RENEW 900 with the spa cover The spa cover must be tight Set the air control to low The water will heat at a rate of 1 7 F an hour If y
14. WITHIN 5 FEET OF SPA NEVER SUBMERGE ENTIRE EQUIPMENT PACK IN WATER REFER TO OWNER S MANUAL FOR PROPER INSTALLATION IMAGE is a registered trademark of ICON Health amp Fitness Inc 5 BEFORE YOU BEGIN Thank you for selecting the IMAGE RENEW 900 The innovative RENEW 900 offers the features and quality of a traditional hot tub at an affordable price Best of all the RENEW 900 is fully portable so you can take it wherever there is an electrical outlet The RENEW 900 allows you to relax and unwind in the comfort of your own home For your benefit read this manual carefully before using the IMAGE RENEW 900 If you have addition al questions please call our Customer Service Spa Cover Side Panel Locking Buckle Inflation Valve Department toll free at 1 888 936 4266 Monday Thursday 8 00 6 30 pm Friday 8 00 am 6 00 pm EST excluding holidays To help us assist you please note the product model number and serial number before calling The model number is 831 100430 The serial number can be found on a decal attached to spa jet unit see the front cover of this manual Before reading further please familiarize yourself with the parts that are labeled in the drawing below Console Under Spa Cover Spa Jet Unit Power Cord Ground Fault Circuit Interrupter 1 CHOOSING A LOCATION FOR THE RENEW 900 There are many factors to consider when choosing a location to set up the
15. am above The function of each console control is explained below Primer This opening allows you to prime the spa jet unit before operation see PRIMING THE SPA JET UNIT on page 10 Diverter Controls the flow of water through the hydro therapy jets and the whirlpool jet The direction of the flow can be adjusted by turning the diverter control When the control is set to front the flow will be through the hydro therapy jets when it is set to side the flow will be through the whirlpool jet when it is set to all the flow will be evenly distributed through both the hydro therapy jets and the whirlpool jet Thermostat Controls the temperature of the water The water heats at about 1 7 F an hour with the cover on The thermostat can be set to heat the water from 70 F to 104 F Use a medical or other accurate ther mometer to check the temperature of the water On Off Turns the spa jet unit on and off When you first press the on off button the spa jet unit will run at low speed providing gentle hydrotherapy Press the button again and the spa jet unit will run at high speed providing more intense hydrotherapy Press the button a third time and the spa jet unit will shut off The spa jet unit also features an automatic mode which heats and filters the water when the spa is left unattended When the spa jet unit is first plugged in or if the buttons on the console have not been used for lo
16. ap from the console Fill the spa jet unit with at least 64 oz of water Replace and tighten the primer cap IMPOR TANT The spa jet unit may be seriously damaged if the pump is not properly primed or if the primer cap is not replaced and fully tightened PRIMER PLUGGING IN THE RENEW 900 Once the RENEW 900 is filled with enough water to cover the water jets and the pump has been primed the power cord can be plugged in and the spa jet unit can be turned on Note The first time the power cord is plugged in the spa jet unit will turn on automatically When connecting the power cord plug the power cord directly into a grounded circuit capable of carrying 15 Grounded circuit capable of carrying 15 or more amps Test and Reset Buttons 10 or more amps No other appliance should be on the same circuit Replace the power cord immediately if it becomes damaged The power cord is equipped with a Ground Fault Circuit Interrupter GFCI located at the end of the power cord You should always test the GFCI before using the RENEW 900 First turn on the RENEW 900 by pressing the power button on the console Once the unit is running press the GFCI test button The RENEW 900 should shut off Press the reset button The RENEW 900 should resume normal operation If the RENEW 900 contin ues to run after the test button is pressed then the GFCI is damaged Do not use the RENEW 900 until the GFCI has been
17. b On Off Switch Assembly Thermostat Knob Primer Cap Housing Screw Console Overlay Micro Switch Wire Control Mounting Screw Control Mounting Nut Motor Mount Bracket Housing Support Bracket Cable Clamp Filter Cover 3 8 Compression Fitting Temperature Tube Trim Primer O ring Short Head Fitting Motor Endcap Motor Cap Screw Pressure Switch Heater Ground Wire Air Pump Key Starter Chemical Pack Chemical Test Strip Pack Warning Decal User s Manual Video Note indicates a non illustrated part Specifications are subject to change without notice 19 VOKON 082001 158 ON ISPOIN ONIMVUG GAdO 1dX4 O voodl LES JISGOW oN d TIIVL3O VIN3HOS V66v0H
18. c filter cycle and freeze protection If the spa jet unit has not been operated for three hours the pump will begin circulat ing the water for twenty minutes to filter any impuri ties Also if the water temperature falls below 40 F the pump will begin circulating and heating the water to prevent the water from freezing DRAINING THE RENEW 900 To drain the RENEW 900 you must use a garden hose to siphon the water Place one end of the hose in the RENEW 900 and hold it in front of a hydro therapy jet until there is a flow of water coming out of the hose Turn off the spa unit and unplug the power cord The unit will be damaged if it is run without water circulating Be sure the end of the hose in the RENEW 900 is on the floor of the spa DRAINING THE PUMP After the RENEW 900 is drained see DRAINING THE RENEW 900 above the pump in the spa jet unit should also be drained if the RENEW 900 will be stored for more than thirty days or if it may be exposed to freezing temperatures To drain the pump remove the spa jet unit from the side pan els Be careful not to tear the inflatable spa liner Locate the pump inside the spa jet unit Remove the drain plug from the pump Tip the spa jet unit slightly until all the water has drained from the pump Replace the drain plug MAINTENANCE CLEANING THE INFLATABLE SPA LINER The liner should be cleaned with a mild soap solution Do not use solvents The liner should
19. etal objects if each metal object is per manently connected to the wire connector on the pump motor of this unit by a minimum No 8 AWG 804 solid copper conductor see instruction 21 DANGER Risk of drowning Exercise extreme caution to prevent unauthorized and unsupervised use of the RENEW 900 by chil dren Children must always be supervised DANGER To reduce the risk of drowning Never use the RENEW 900 alone Children should not use the RENEW 900 unless they are supervised by an adult Keep pets away from the RENEW 900 at all times Always replace and lock the spa cover when the RENEW 900 is not in use WARNING To reduce the risk of injury The water temperature should never exceed 104 F 40 C Temperatures between 100 F 38 C and 104 F 40 C are considered to be safe for healthy adults However if you plan to remain in the RENEW 900 for more than 10 to 15 minutes a lower temperature is rec ommended Lower temperatures are also rec ommended for children WARNING To reduce the risk of injury Always use an accurate thermometer to determine the water temperature before using the RENEW 900 27 28 29 30 31 32 WARNING To reduce the risk of injury Pregnant women should consult with their physician before using the RENEW 900 Pregnant women should not use the RENEW 900 if the water temperature is above 100 F 38 C the unborn child could be seriously harmed
20. hase Date Retailer Address ICON of Canada Inc 900 de l Industrie St J r me Qu bec Canada J7Y 4B8 18 LIMITED FIVE YEAR MASSAGE SPA WARRANTY ICON OF DU CANADA ICON warrants this product to be free from defects in workmanship and material under nor mal use and service conditions for a period of ninety 90 days from the date of purchase ICON extends a limited five 5 year warranty on the spa shell structure ICON also extends a limited two 2 year warranty on the pump and motor This warranty extends only to the original purchaser ICON s obligation under this warranty is limited to replacing or repairing at ICON s option the product through one of its authorized service centers All repairs for which warranty claims are made must be pre authorized by ICON This warranty does not extend to any product or damage to a product caused by or attributable to freight damage abuse misuse improper or abnormal usage or repairs not provided by ICON authorized service per sonnel to products used for commercial or rental purposes or to products used as store display models Specifically exclud ed are damages caused by or attributable to the following incidents any damage to the wood exterior resulting from improp er maintenance or any damage to the wood or tile exterior attributable to freight mishandling damage resulting from improp er winterization damage to the spa shell resulting from improper chemical treatme
21. he RENEW 900 This could damage the motor and will void the warranty DANGER If you will be using the RENEW 900 outside do not bury the power cord you should also keep the power cord away from lawn mowers hedge trimmers and other similar equipment WARNING The power cord is equipped with a Ground Fault Circuit Interrupter GFCI located at the end of the power cord The GFCI must be tested before each use To test the GFCI press the test button while the spa jet unit is running The spa jet unit should shut off Press the reset button The spa jet unit should resume normal oper ation If the spa jet unit continues to run after the test button is pressed then the GFCI is damaged Do not use the RENEW 900 until the GFCI has been repaired or replaced by a qualified electrician 20 21 22 23 24 25 26 Keep all electrical appliances such as radios telephones televisions and lights at least five feet 1 52 meters away from the water A wire connector is provided on the pump motor of this unit to connect a minimum No 8 AWG 804 solid copper conductor between this unit and any metal equipment electrical enclosure made of metal metal water pipes or conduit within five feet 1 52m of the unit DANGER Risk of electric shock Do not set up the RENEW 900 within five feet of any metal objects or surfaces As an alternative you may use the RENEW 900 within five feet of m
22. he RENEW 900 if the suction guard is missing or broken Keep hair and body away from the suction guard If you need to replace a suction fitting be sure that the flow rate of the replacement is compatible Do not bring any object into the RENEW 900 that could puncture the liner Never insert any object into any opening Do not sit on the spa cover or place objects on it It is not designed to support weight Remove any water which may collect on the spa cover Keep children and pets away from the RENEW 900 when it is not in use 13 14 15 16 17 18 19 Keep all chemicals away from children and pets The pH and chemical balance of the water must be maintained as explained in this man ual See page 13 Failure to do so may cause injury to users or damage to the spa jet unit and will void the warranty The water pump in the spa jet unit must be primed before you use the RENEW 900 the first time You must also prime the pump before using the unit each time you re fill the spa The spa jet unit may be seriously dam aged if the pump is not properly primed see PRIMING THE SPA JET UNIT on page 10 DANGER When connecting the power cord see PLUGGING IN THE RENEW 900 on page 10 plug the power cord directly into a grounded circuit capable of carrying 15 or more amps No other appliance should be on the same circuit Replace the power cord immediately if damaged Do not use an extension cord with t
23. he Spa Cover 11 through one of the loops on the Inflatable Cover 4 Attach the latch on the strap to the buckle on the other end Attach the other three straps on the inside of the Spa Cover 11 through the loops on the Inflatable Cover 4 in the same manner 7 Place the Spa Cover 11 over the Side Panels 1 2 and the Spa Jet Unit 13 Be sure that the Spa Cover is properly centered and that the straps on the Spa Cover line up with the straps extend ing from the slots in the Side Panels 1 2 Snap each of the six latches on the Spa Cover 11 into the buckles on the straps extending from the slots in the Side Panels 1 2 Latch and Buckle USING THE RENEW 900 The RENEW 900 is designed for up to four adults The six water jets can be regulated to provide a relax ing massage to sooth away stress and the strength of the water massage can be adjusted by the air con trol The RENEW 900 holds 300 gallons of water and offers an automatic programmable heating 70 F to 104 F and filtration system The guidelines below explain how to properly use the RENEW 900 Follow these guidelines to maintain the RENEW 900 for your long term enjoyment PRIMING THE SPA JET UNIT The water pump in the spa jet unit must be primed before you use the RENEW 900 the first time You must also prime the pump before using the unit each time you re fill the RENEW 900 To prime the spa jet unit remove the primer c
24. i oad mee extet nim m X Pe ae ollie go pO GRE EUR eee DP Fk 14 ORDERING REPLACEMENT PARTS 16 LIMITED WARRANTY wists Beach rex ete Gc tales eade k eeu oce MER es 17 Note A PART LIST and an EXPLODED DRAWING are attached to the center of this manual IMPORTANT SAFETY INSTRUCTIONS WARNING To reduce the risk of drowning electric shock or serious injury read the following important precautions before using the RENEW 900 READ AND FOLLOW ALL INSTRUCTIONS 10 11 12 It is the responsibility of the owner to ensure that all users of the RENEW 900 are ade quately informed of all precautions Use the RENEW 900 only as described in this manual The RENEW 900 is intended for home use only Do not use the RENEW 900 in any com mercial rental or institutional setting Use the RENEW 900 only on a level surface Do not use the RENEW 900 on carpet or other materials that could be damaged by moisture Do not use the RENEW 900 on rough or sharp surfaces such as gravel or wood chips The RENEW 900 will weigh approximately 2400 pounds when it is assembled and filled with water Be sure that the location you select for the RENEW 900 will support this weight plus the weight of the occupants Inspect and tighten all parts regularly Replace any worn parts immediately DANGER Risk of injury Do not remove or alter the covers on the suction fittings Never operate t
25. intained Damage caused by improper pH levels is not covered under the warranty To maintain the proper pH level you should test the pH of the water regularly To test the water you can either purchase additional test strips or purchase a pH test kit at a pool and spa supply store The pH read ing should be between 7 2 and 7 8 If the level is too low add a pH increaser usually soda ash If the level is too high add a pH reducer usually sodium bisulfate Test the water again after five minutes See the instructions with your test strips or pH test kit for additional information about testing and adjusting the pH SANITIZING THE RENEW 900 Please refer to your local pool and spa supplier for information concerning which chemicals you should use in your area to sanitize the spa The most common sanitizing agent is a solid bromine concentrate The amount required varies according to several factors such as user load temperature water conditions and so forth Proper water maintenance is a fairly complex process We recommend that you contact your local pool and spa supplier for information on how you should best accomplish this TROUBLE SHOOTING Most problems can be solved by following the simple steps below Find the symptom that applies and follow the steps listed If further assistance is needed call our Customer Service Department toll free at 1 888 936 4266 Monday Thursday 8 00 6 30 pm Friday 8 00 6 00 pm E
26. latable Spa Liner 9 into the Fabric Spa Surround Align the valve in the Inflatable Spa Liner with the hole in the Fabric Spa Surround and the Inflation Side Panel 2 Flip the flap on the Fabric Spa Surround 8 over the low section of the Inflatable Spa Liner 9 Inflate here second be visible in this hole 4 Remove the power cord from the Spa Jet Unit 13 With the help of a second person place the Spa Jet Unit 13 over the Side Panel 1 and the section of the Inflatable Spa Liner 9 which does not have the cushion Be extremely careful not to tear the Inflatable Spa Liner 9 as you slide the Spa Jet Unit into place 5 Before you fill the RENEW 900 be sure that it is in the position you want and that it can be easily ser viced if needed Once the RENEW 900 is filled with water it will need to be drained to be moved Using a garden hose or other clean water source begin filling the RENEW 900 until the jet and filter openings on the Spa Jet Unit 13 are covered with water Do not fill the RENEW 900 more than 20 deep with water After the RENEW 900 is full you must prime the Spa Jet Unit 13 before using the RENEW 900 see PRIMING THE SPA JET UNIT on page 10 6 Attach the nozzle on the included air pump to the valve on the Inflatable Cover 4 Use the Air Pump to fill the Inflatable Cover 4 with air Remove the nozzle from the Inflatable Cover Slide one of the straps on the inside of t
27. ng this product If you feel pain or dizziness at any time while using the RENEW 900 discontinue use and contact a physician WARNING Read all instructions before using the RENEW 900 ICON assumes no responsibility for personal injury or property damage sustained by or through the use of this product SAVE THESE INSTRUCTIONS WARNING DECAL PLACEMENT The decals shown below have been placed on the RENEW 900 If a decal is missing or if it is not legible please call our Customer Service Department toll free at 1 888 936 4266 Monday Thursday 8 00 am 6 30 pm Friday 8 00 6 00 pm EST excluding holidays to order a replacement decal Apply the decal in the location shown A WARNING AVOID DROWNING RISK STAY OFF COVER WILL NOT SUPPORT WEIGHT KEEP CHILDREN AWAY CHILDREN OR OBJECTS CANNOT BE SEEN UNDER COVER REMOVE STANDING WATER CHILD CAN DROWN ON TOP OF COVER REMOVE COVER S COMPLETELY BEFORE ENTRY OF BATHERS ENTRAPMENT POSSIBLE NON SECURED OR IMPROPERLY SECURED COVERS ARE AHAZARD FAILURE TO FOLLOW ALL INSTRUCTIONS MAY RESULT IN INJURY OR DROWNING THIS IS NOTA SAFETY COVER WARNING PREVENT DROWNING SUPERVISE CHILDREN AT ALL TIMES ATTACH SPA COVER AFTER EACH USE SPAHEAT CAN CAUSE HYPERTHERMIA AND UNCONSCIOUSNESS SPAHEAT IN CONJUNCTION WITH ALCOHOL DRUGS OR MEDICATION CAN CAUSE UNCONSCIOUSNESS PREVENT ELECTROCUTION NEVER PLACE ANY ELECTRIC APPLIANCE
28. nger than twenty minutes the automatic mode will begin filtering or heating the water as needed Note to keep the filter and heat cycles from run ning the power cord must be unplugged Air Control Determines the amount of air that is in the spa jet system during operation If the control is turned to the left the amount of air flowing through the jets will increase If the control is turned to the right the amount will decrease SPA JET UNIT OPERATION The spa jet unit features five hydro therapy jets a whirlpool jet a suction vent and a filter housing The five hydro therapy jets A located on the front of the spa jet unit focus the water massage on your neck and back The whirlpool jet B located on the left side of the spa jet unit directs the flow of the water to create a whirlpool action in the RENEW 900 The suction vent C located on the right side of the spa jet unit pulls the water into the spa unit in order to operate the system The suction cover should always be in place over the suction vent Never operate the RENEW 900 without the suc tion cover in place The filter D is locat ed on the left side of the spa jet unit behind the filter cover The filter can be removed for cleaning and replacement by D removing the Filter Cover and the two filter cover screws and then pulling the filter from the spa jet unit Filter Cover The spa jet unit features an automati
29. nt damage to the spa shell resulting from exposure to extreme temperatures or damage to the spa shell resulting from exposure to direct sunlight and ultraviolet rays while the spa is empty damage to the pump motor plumbing and components due to improper maintenance chemical treatment or exposure damage resulting from failure to properly follow user s manual installation operating or mainte nance instructions Also excluded are consumable components including but not restricted to headrests filter cartridges and light bulbs No other warranty beyond that specifically set forth above is authorized by ICON ICON is not responsible or liable for indirect special or consequential damages arising out of or in connection with the use or performance of the product or damages with respect to any economic loss loss of or damage to property including water damage loss of revenues or profits loss of enjoyment or use costs of removal installation or other consequential damages of whatsoever nature Some provinces do not allow the exclusion or limitation of incidental or consequential damages Accordingly the above limitation may not apply to you The warranty extended hereunder is in lieu of any and all other warranties and any implied warranties of merchantability or fitness for a particular purpose is limited in its scope and duration to the terms set forth herein Some provinces do not allow limitations on how long an implied warranty lasts Acc
30. ordingly the above limitation may not apply to you This warranty gives you specific legal rights You may also have other rights which vary from province to province ICON OF DU CANADA 900 de l Industrie St Jer me QC J7Y 4B8 Se Serr e EET jj ICON IMAGE PRODUCT WARRANTY REGISTRATION IMPORTANT MAIL WITHIN 14 DAYS OF PURCHASE ADDRESS COUNTY POSTCODE MODEL NO SERIAL NO __ PURCHASE DATE RETAILER NAME _ RETAILER ADDRESS 1 1 Primary user s of product 8 Did you consider purchasing fitness equipment from another 1 Male Female Family manufacturer 2 Age of primary user NS Yes H 0 24 Q 35 44 J 55 64 What other Manufacturer 25 34 1 45 54 65 andover 9 Based on your impression of what you have purchased 3 Annual household income would you buy another ICON product a 1 0 0 9 999 15 000 19 999 Yes No Opinion 10 000 14 999 T 20 0004 If not what other brand name equipment would you purchase 1 l 4 How many times a week do you exercise 9 1 Less than 3 times 3 times or more 10 a bevels type of exerc PAA Treadmil i 5 Have you ever purchased an ICON product before C Home Gym Weight Bench Stepper J Yes No Cardio Glide Q Other
31. ou are using the spa indoors and the room temperature is main tained at 70 F it will take approximately 20 to 28 hours for the water to reach the set temper ature If you are using the RENEW 900 outdoors it may take longer for the water to heat See the chart below for the approximate heating time Air Temperature Heating Time 70 F 20 to 28 hours 50 F 70 F 1 to 2 days 30 F 50 F 2 to 3 days If the water still has not heated after three days contact our customer service department SYMPTOM THE WATER PULSATES OR THERE IS MINIMUM WATER FLOW a Adjust the water level This usually occurs only when the water level is low Add water until the filter and jets are covered This problem is caused by excess air in the pump circulation system Check to see if the primer cap is fully tightened Prime the pump again and fully tighten the primer cap see PRIMING THE SPA JET UNIT on page 10 SYMPTOM THE SPA JET UNIT CAVITATES DURING USE a Adjust the water level This usually occurs only when the water level is low Add water until the filter and jets are covered This problem is caused by excess air in the pump circulation system Check to see if the primer cap is fully tightened Prime the pump again and fully tighten the primer cap see PRIMING THE SPA JET UNIT on page 10 SYMPTOM THE WATER IS NOT BEING CLEANED BY THE FILTER a Check to see if the filter is in place Clean the filter
32. patch it using a pool patch kit that you can pur chase at any pool and spa supply store A clamp or seal inside the spa jet may be loose Check the floor around the spa jet unit for excess water and watch the spa jet unit while it is operating to see if water drips from the spa jet unit housing If you can identify the location of the leak inside the spa jet unit tight en the clamp or replace the damaged seal SYMPTOM THE INFLATABLE SPA LINER LOSES AIR a Over time some air loss is normal If rapid air loss occurs then the liner may have an air leak Locate the leak and patch it using a pool patch kit that you can purchase at any pool and spa supply store ORDERING REPLACEMENT PARTS To order replacement parts simply call our Customer Service Department toll free at 1 888 936 4266 Monday Thursday 8 00 am 6 30 pm Friday 8 00 am 6 00 pm EST excluding holidays To help us assist you please be prepared to give the following information when calling 1 The MODEL NUMBER of the product 831 100430 2 The NAME of the product IMAGE RENEW 900 3 The SERIAL NUMBER of the product see the front cover of this manual 4 The KEY NUMBER and DESCRIPTION of the part s see the PART LIST EXPLODED DRAWING attached to the center of this manual Part No 154868 J00726 C R0499A Printed in USA 1999 ICON Health amp Fitness Inc 16 CUSTOMER RECORD Model Serial No Retailer Purc
33. s or privacy concerns that may affect the safety or enjoyment of using the RENEW 900 If you set up the RENEW 900 outside 1 You should check your local building codes con cerning the use of outdoor spas The location must be close to an electrical outlet Do not use an extension cord with the RENEW 900 The RENEW 900 should be close to a source of water We recommend that you place the RENEW 900 on a water and stain resistant non slip surface Be sure that the location you choose is stable It must be able to support the weight of the RENEW 900 when it is filled with water plus the weight of the occupants The RENEW 900 weighs approxi mately 2400 pounds when filled with water Think about environmental factors such as rain wind shade sunlight and so forth You should be able to monitor the use of the RENEW 900 from your home to prevent unautho rized use by children Be sure that there is room around the RENEW 900 to permit servicing of the unit The diameter of the tub is 69 You should allow for this size plus the size of the spa jet unit when choosing the location Be sure to note any other considerations such as aesthetics or privacy concerns which may affect the safety or enjoyment of using the RENEW 900 ASSEMBLY Before beginning assembly carefully read the following information and instructions Place all parts in a cleared area and remove the packing ma
34. terials do not dispose of the packing materials until assembly is completed Assembly requires two people Assembly requires the included air pump Read each assembly step before you begin During assembly make sure that all parts are ori ented as shown in the drawings 1 Before beginning assembly be sure that you have read and understand the information in the box above and on the previous page Unfold the pre assembled Fabric Spa Surround 8 and Side Panels 1 2 until the assembled unit is round Check the self attaching connections between the Fabric Spa Surround 8 and Side Panels 1 2 to be sure that all connections are firm Be sure that all six cover buckles are fully inserted through the slots in the Side Panels 1 2 Unfold the Inflatable Spa Liner 9 Attach the nozzle on the included air pump to the valve on the side of the Inflatable Spa Liner 9 Use the air pump to fill the sides of the Inflatable Spa Liner with air Attach the nozzle on the air pump to the valve on the floor of the Inflatable Spa Liner 9 Use the air pump to fill the bottom of the Inflatable Spa Liner with air Attach the nozzle on the air pump to the valve on top of the Inflatable Spa Liner 9 Use the air pump to fill the cushion on top of the Inflatable Spa Liner with air Be sure that the flap on the Fabric Spa Surround 8 is on the outside of the Fabric Spa Surround and Side Panels 1 2 Insert the Inf
35. water to circulate for five min utes You should now test the pH level of the water Use the included test strips to check the pH of the water Refer to the instructions on the test strip pack aging to see how to use the test strips If the level is too low add half of one of the QUICK pHix It UP packets to the water Let the water circu late through the spa jet unit for five minutes Test the pH level again Repeat until the pH level is correct If the level is too high add half of one of the QUICK pHix It DOWN packets to the water Let the water cir culate through the spa jet unit for five minutes Test the pH level again Repeat until the pH level is correct Replace the spa cover and allow the water to contin ue to heat See WATER CHEMISTRY on page 13 for information concerning proper water maintenance DIAGRAM OF THE CONSOLE PRIMER DIVERTER SECURING THE SPA COVER The spa cover can be secured by snapping the latch es on the spa cover into the buckles on the side panels The buckles can be locked by inserting the key and turning it clockwise a quarter turn To unlock the buckles insert the key and turn it counter clockwise a quarter turn Always keep the buckles locked when the spa is not in use Keep the keys in a safe place out of the reach of children AIR CONTROL a FRONT 2 f 4 IMPORTAN and fill with USING THE CONSOLE Refer to the console diagr
Download Pdf Manuals
Related Search
Related Contents
Bretford ECILS1-BPMBT Samsung DVD Home Entertainment System E350K Керівництво користувача Let`s try out your new IC recorder 1. Charge. 2. Power on. 3. Set the MANUEL D`UTILISATION GRILLE-PAIN Serie VX-410E/-420E Manual de instrucciones DVR2304 DVR8308 DVR8316 - tec security applications COMPÉTITION DE VOILE JEUX PANAMÉRICAINS TO2015 環境報告書2011 formulaire drone Copyright © All rights reserved.