Home

Ikelite Olympus Mju780 User's Manual

image

Contents

1. Mounting Tray Mounting Bolt CAMERA MOUNT Some camera tripod socket threads are plastic The mounting tray bolt is metal Do not cross thread or over tighten as you may damage the camera tripod socket threads Release ceace i TI Lid Snap Front View O Arrow Fad O Oj Display 7 View OK Button EE Back View 2 Closing the Housing i pA lap or on a flat surface Place housing face down in your housing Check to see that there is an o ring on the housing back aw G and that it is clean and in its proper location Guide the back onto the housing The o ring should touch the housing all the way around There should be an even gap all the way around between the housing and the housing back Lift the lid snaps so they are extended and place the lid housing O ring housing housing back snap into the hook on the ae To close the housing push even gap all 4 sides down on the lid snaps until they snap into place Lid i snaps on opposite sides of the housing should be closed at the same time Be sure they are down far enough to engage the lock O ring housing Double check Once the housing is closed check the o ring seal Check the gap between the housing back and the housing it should be even all the way around Look through the clear plastic back at the o ring
2. Check each control gland to make sure they are tight There is a slight chance that either could vibrate loose during travel 4 Keep the back o ring clean and lightly lubricated To lubricate SA 100R remove the o ring from the back Put a small amount of Ikelite lubricant on your fingers Draw the o ring through your fingers to apply a light coating of lubricant Only apply enough lubricant to make the o ring feel slick Do Not stretch the o ring This light coating of lubricant will help to keep the o ring from drying out and will help to show a dark sealing line when the housing back is properly sealed 5 Keep the area where the o ring fits and the sealing surface of the housing clean 6 Rinse the housing exterior in fresh water after each salt water use Dry with a soft cloth Dry lens port to eliminate spotting SA 10OOR EV Controller EV a Substrobe DS51 Substrobe DS125 After several uses in salt water soak the housing in a mild soap solution rinse and dry before storage When storing the The Substrobe DS51 covers The Substrobe DS125 covers housing remove the back o ring lightly lubricate and place the equivalent of a 28mm lens the equivalent of a 18mm in a plastic bag Place the plastic bag with o ring inside the It is the ideal choice when lens 100 degrees It is the housing for safe keeping using only the camera lens ideal choice when using CAUTION or the camera lens with a accessory wide angle lenses Never u
3. 3 As soon as you enter the water take a moment and check the housing to see that it is properly sealed 4 Next check to see if there are any bubbles on the face of the lens port If there are take your finger and remove them If there are bubbles on the lens port they can produce soft focus spots in your photographs 5 If you use the housing Zoom control make sure to move it back to the center position If the housing Zoom control is pushing the camera zoom lever to either side the camera will not function 15 Some of the controls have a short shaft and cannot be pulled out exposing the shaft for lubrication In the unlikely event one of these controls sticks or becomes difficult to operate you can remove the control from the housing and lubricate it or return the housing to Ikelite for maintenance To remove the control loosen the set screw in the knob allen wrench required remove the knob If there is salt or dirt build up on the exposed control shaft clean the shaft Open the housing and gently slide the control shaft out of the control gland Clean and lightly lubricate the shaft including the end of the shaft Slide the shaft back into the control gland and gently slide it back and forth a few times without fully removing the shaft from the gland Replace the knob NOTE the flat area on the shaft the set screw in the knob should tighten down against the flat area on the control so the knob does not turn on the shaft ho
4. with your name address phone number and a brief description of the problem Evidence of purchase date must be provided to obtain warranty service Ikelite Underwater Systems 50 W 33rd Street Indianapolis IN 46208 USA 317 9 23 4523 email ikelite ikelite com www ikelite com Digital 6138 78 00607
5. Ikelite Digital Housing instruction manual 6138 78 for Olympus Stylus 780 Mju780 Congratulations on your purchase of an Ikelite Digital Camera Housing Ikelite has over 30 years of experience in the underwater photographic and lighting market Our products are designed and built in the USA by Ikelite for both the professional and amateur photographer The clear housing permits instant visual inspection of the camera and all sealing surfaces as well as complete monitoring of controls and camera LCD screens Ikelite Digital Housings are slightly negative in salt water for stability This housing has been water pressure tested at the factory Housing is pressure tested to 200 60m Opening the Housing 1 Lid Snaps have a Lock To open push Lid Snap Lock forward and lift as shown Keep pressure on the Lid Snap so it does not fly open quickly Some lid snaps have a lot of spring tension once they go over center have a firm grip on the lid snap Lid Snaps may be opened one at a time Push Forward Installing the Camera 1 CAUTION Remove the back from the housing The mounting tray for the camera is secured to the housing back Position the camera on the tray and secure it with the mounting bolt which threads g into the camera s tripod socket Use Lid a coin or flat bladed ok screwdriver to tighten the mounting bolt so the camera is flat against the tray
6. You should see a darkened area where the o ring is compressed against the housing back If you do not see an even black compression seal all the way around the back open the lid snaps reseat the housing back and close the lid snaps Visually check the seal again 4 Checking Controls Once the housing has been closed make sure the housing controls line up with the camera s controls If the housing controls are misaligned slightly make sure the camera hold down bolt has been tightened down firmly so the camera is flat against the tray Turn Camera On Turn the camera on and operate each of the housing controls to get a feel for using the camera in the housing Take a few pictures above water with the camera in the housing Lens Port Treat the glass in the lens port as a camera lens After use rinse and gently dry the lens port to avoid water spotting To clean use a mild soap solution or lens cleaner Do not use alcohol or window cleaner on the Lens Port The Lens Port will accept 2 Wide Angle Adapters The Wide Angle Adapter 9306 80 which is required to mount the Inon UWL 150AD Bayonet style wide angle lens The Wide Angle Adapter 9306 81 is required to mount the 6420 Ikelite W 20 Wide Angle Lens and other manufacturers 67mm screw thread style wide angle lenses These lenses can be secured onto the Wide Angle Adapter above or below water as they are designed to have water between the front of the port and the accessory l
7. e For available light built in flash creating a shadow in the lower left of the photo only not recommended for use with flash If this occurs zoom the lens slightly to eliminate the shadow You can test this above water Tray with Release Handle 9523 31 Tray and Release Handle is required Deflector to mount external Substrobes The deflector should be installed when using an external strobe such as the DS51 or DS125 Substrobe and EV Controller The Ikelite W 20 Wide Angle Lens 6420 deflector will redirect the camera s flash to the EV Controller Wide Angle lenses allow you to capture more of the scene and which controls the external strobes output get closer to your subject which results in clearer images and more vivid color Can be installed or removed underwater for maximum versatility Note some housings may require an adapter see instructions 9 10 Optional Accessories Continued Sabet Maintenance D5125 The Ikelite Digital Housing should be given the same care and attention as your other photographic equipment In addition to Substrobe normal maintenance we recommend that the housing be returned D551 gt gt to Ikelite periodically to be checked and pressure tested 1 Do Not leave the camera and housing in direct sunlight for prolonged periods Heat may damage the camera 2 Do Not ship the camera in the housing 3 Before using the housing always check the tightness of the set screw in each control knob
8. ens Make sure no air bubbles are trapped between the port and the accessory lens Any vignetting that occurs can be eliminated by zooming the camera lens slightly The camera s built in flash cannot be used with wide angle lenses The front of the lenses are so large they block the camera s flash To properly light subjects a when using a wide angle lens an external strobe g should be used Due to the wide angle of coverage of these lenses the DS125 Substrobe is recommended or two DS51Substrobes Wide Angle Adapter Wide Angle Lens Lubricants 1 Ikelite provides silicone lubricant with the housing We recommend you use only Ikelite lubricant on Ikelite products as some other brands may cause the o ring to swell and not seal properly 2 Use only enough lubricant to lightly cover control shafts and o rings Wipe off any excess lubricant with a clean cloth Lubricant is not a sealant it is used to reduce friction Excessive lubricant can collect sand and dirt which may interfere with proper sealing CAUTION Never use spray lubricants as the propellant ingredient can cause the plastic housing to crack 6 Using Flash Using the Camera s Built in Flash If you do not have an external flash the camera s built in flash can be used See Diffuser instructions NOTE The camera s built in flash cannot be used with optional Wide angle lenses Diffuser and Deflector Installation Diffuser Housing sho
9. o adjust your camera for what you like exposure wise Many cameras allow you to adjust both available light and flash exposure with an EV control 6 Many photographers transfer their images to the computer where they can fine tune the appearance of the image Many of the image manipulation programs make you think you can magically correct any image taken and make a good picture One thing to remember when using image manipulation programs if the image is overexposed much of the color is missing If the color is missing you cannot adjust it If images are underexposed some color and detail may be there it is just dark and you can adjust it to some degree So if you error in exposure it is better to have the image slightly underexposed than over exposed 17 Ikelite Limited Warranty All Ikelite products are warranted against any manufacturing defects for a period of one year from the date of purchase Defective products should be returned prepaid to Ikelite Ikelite will at its discretion repair or replace such products and will return to customer prepaid All other claims of any nature including but not limited to bulb failure are not covered Except as mentioned above no other warranty expressed or implied applies to this Ikelite product Returning Products for Service Ikelite is most interested in preforming any service to assure that all products perform as intended For repair or service return the product to the address below
10. se spray lubricants as the propellant ingredient can cause the plastic housing to crack 11 12 macro accessory lens greater than 28mm Control Maintenance Ikelite controls are designed to provide years of reliable service with minimal maintenance 1 Push button controls require no maintenance other than rinsing in fresh water after saltwater use If a push button control becomes difficult to push or if it sticks when depressed soak the housing in luke warm fresh water After a few minutes operate the push button If this does not correct the problem return the housing to Ikelite for maintenance 2 Some of the controls have long shafts These controls can be lubricate shaft housing pull out to expose shaft pulled out exposing the shaft see drawing To lubricate the control gently pull on the knob until the stainless steel shaft is exposed Lightly lubricate the shaft then move the shaft in and out several times This will lubricate the x ring in the Ikelite control gland This should be done before using the housing after a prolonged storage period or once a week when the housing is in use continued on next page 13 General Tips 1 Due to the power required to operate the camera flash and LCD screen it is a good idea to start each dive with a fresh set of batteries 2 Some cameras reset their flash to AUTO when the camera is turned on If you prefer another setting be sure to select it
11. usin control gland shaft Loosen set screw allen wrench required Flat Tighten set screw down against this area when replacing the knob Lubricate end of shaft before reinserting into gland 14 Photo Tips i The number one rule in underwater photography is eliminate as much water between camera and subject as possible Get as close as you can to the subject then use the zoom If you are using flash subjects beyond 6 feet 1 8m will not have much color Digital cameras have a slight lag time between when you press the shutter release button and the camera actually takes the picture Hold the camera steady a second or two after pressing the shutter release button Do not shoot down on subjects as they will quite often blend into the background and be difficult to see in the photograph Shoot subjects straight on or shoot up at a slight angle using the blue water as a contrasting background Underwater flash is used to restore the warmer colors filtered out by the water as well as to illuminate the subject When photographing underwater set the camera to use flash on every shot If the camera s flash is set to AUTO and the sun is behind your subject the camera may see enough light that it does not fire the flash With the sun behind the subject the subject is shaded dark and needs flash for a good exposure 16 Photo Tips Cont 5 Since opinions vary on what is the correct exposure you may want t
12. wn with Diffuser installed Diffuser and Deflector cont Optional Accessories Diffuser A diffuser and deflector are Deflect included with the housing The a Back o ring 0109 O rings last for several years if properly maintained See maintenance Always carry a spare in case o ring becomes damaged or lost diffuser is white transparent plastic The deflector is also white but is not transparent Wide Angle Adapter 9306 80 To install the diffuser or l l Required to mount Inon UWL 150AD Bayonet style wide angle lens deflector spread the port clamp at the spring end and slide over the lens port The white plastic should be placed in front of the camera flash Wide Angle Adapter 9306 81 Required to mount Ikelite W 20 and other Screw Thread 67mm style wide angle lenses a A pe This edge UR Pro Filter Blue Water 6441232 aaa aah din ys Spi Spread to Install The UR Pro underwater color correcting filter is designed to restore some of the warm colors filtered out by the water For Diffuser available light use only not recommended for use with flash The diffuser should be installed when using the camera s built in flash When shooting with the camera s built in flash at Green Water Filter 6441 72 approximately 2 feet 0 6 m or less the lens port on the Enhances contrast and alters the color of green water to housing may block a portion of the light from the camera s give our subject a rich natural ton

Download Pdf Manuals

image

Related Search

Related Contents

GH40 Service Part A  Istruzioni per l`uso IT  Hampton Bay 25722-HBU Instructions / Assembly  Descargar PDF - Dirección de Hidrografía y Navegación  Divosan TC86 - SOPECAL HYGIENE  

Copyright © All rights reserved.
Failed to retrieve file