Home

hussman MAXI-140 User's Manual

image

Contents

1. 7 00 P M This scheme applies to all types of defrosts Setting this parameter is done in the dEFr menu After navigating to the ndEF submenu item the display will cycle between ndEF and the current setting While the setting 1s being displayed press the SELECT button to edit this value When the Safe NET display module begins flashing the value use the UP DOWN buttons to increase or decrease the value to the desired setting P N 31033596_B 01 June 2007 P N 31033596_B 01 June 2007 Once the desired setting is displayed press the SELECT button to store the new value The display will revert to cycling between ndEF and the new value If it is necessary to stagger the defrost times to uneven intervals select 2 df in the ndEF item This enables Str2 in menu which 1s the second defrost time and allows the first and second defrost times to be set independently An example would be 02 00 and 13 00 For three staggered defrost times select 3 dF which enables Str2 and Str3 defrost times Defrost should be scheduled for a time imme diately following product loading to allow for the fast pull down Replace Safe NET Cover Position the cover over the display and gently press into place The complete Safe NET technician s manual is available online at http www hussmann com docs inst_manuals other 0461391A_SafeNET pdf Run Before Stocking Allow the Chill Chamber to run at least 30 minutes before stoc
2. HUSSMANN nheusev Rusch Jac ONE OF THE ANHEUSER BUSCH COMPANIES ca BL CHAMBER vi f Gos con HHA HH E E PELAT MAXI 140 Operator s Manual P N 31033596_B 01 June 2007 am Ingersoll Rand Climate Control Technologies These merchandisers are manufactured to meet ANSI National Sanitation Foundation NSF Standard 7 Type II requirements Proper installation is required to maintain certification Near the serial plate each case carries a label identifying the type of application for which the case was certified ANSI NSE 7 Type II Display Refrigerator Freezer Beverage Cooler Intended for 80 F 55 RH Ambient Application This equipment is intended for the storage and display of nonpotentially hazardous bottled or canned products only Copyright Notice Hussmann and Safe NET are trademarks of Hussmann Corporation Chill Chamber is a trademark of Anheuser Busch Inc P N 31033596_B 01 June 2007 SAFETY FIRST Before installing read and understand the operating manual Any damage caused by not following directions given in this manual is out of warranty A CAUTION To reduce the risk of fire electrical shock or injury when using your Chill Chamber e Always use a dedicated circuit with the Amperage stated on the unit e Plug into an outlet designed for the plug e Do not use an adapter e Do not overload the circuit e Disconnect power before servicing
3. OPERATING TIPS e The unit must be allowed to stand in place for 30 minutes before it 1s plugged in e Once the unit is running the real time clock must be set Once fully charged the real time clock s battery will keep the clock memory for at least one week e In the event of power loss the real time clock will keep its settings for at least one week once the battery is fully charged The real time clock battery is rechargeable e The unit should run for 30 minutes empty and must be within 2 degrees of 22 F before any product is loaded inside e The unit must go into defrost mode twice a day to maintain optimal performance During defrost the temperature display may move up 2 or 3 F 1 to 1 5 C Avoid opening the door during the defrost cycle e If the unit is placed in a location that is not air conditioned or has high ambient humidity additional defrost cycles may be required to prevent the rear refrigeration coil from blocking with ice e Very frequent door openings will eventually have an impact on product temperature and cause it to rise Avoid holding the door open while deciding on product selection counting inventory etc e The large blue LED display above the door simulates the average temperature of the beer in the cooler not the air temperature in the unit Therefore the display temperature will change slowly as the unit cools down or warms up 2007 HUSSMANN CORPORATION e BRIDGETON MO 63044
4. 140 Chill Chamber light switch is minimum size wire acceptable located on the right rear of the interior top panel It controls the exterior canopy light e The MAXI 140 LED lighting is ON at all times requires a dedicated 15 Amp circuit with grounded wall receptacle NEMA 5 15P NEMA 5 15P SiS ous e Do not use extension KA A cords Never use adapters MAXI 140 d If in doubt call an electrici e n in doubt call an electricia Ki iii 2007 HUSSMANN CORPORATION BRIDGETON MO 63044 2483 U S A TM U S amp CANADA 1 800 504 4828 e WWW CHILLCHAMBER HUSSMANN COM CELL TA LE IN EZ ER 4 MAXI 140 INSTALL SHELVES The MAXI 140 comes standard with one fixed wire shelf with dividers for 160z aluminum bottles and one removable flat wire shelf for 160z aluminum bottles The removable lower shelf must be placed flush against the back to maintain proper air flow and product temperature Fixed Upper Shelf 1 na NE EYN Vis NNN f P i F d id F if j j ae EL NV Ki AN x H D i Si in FRE nr nn Shelf Fasteners Removable Lower Shelf with Product Stop to Rear 2007 HUSSMANN CORPORATION e BRIDGETON MO 63044 2483 U S A U S amp CANADA 1 800 504 4828 e WWW CHILLCHAMBER HUSSMANN COM DOOR HINGES The MAXI 140 Chill Chamber door is not self closing The top door hinge has slots that allow the door to be adjusted if the gasket doesn t seal completely Use a nut driver to l
5. access remains active for 5 minutes Each time a new parameter is entered by pressing the SELECT button on the Safe NET display module the 5 minute timer is restarted After 5 minutes with no parameter entries the pass code value reverts to 0 and the pass code entry process must be performed to regain access Any time you want to change defrost times you will need to set up the pass code before being able to make the necessary changes Escape To leave a Menu and return to the default display press the UP and DOWN buttons on the Safe NET display module simultaneously If a valid pass code has been entered it will remain active for the remainder of the 5 minute time out period This allows exiting one menu and entering another to modify a value without having to re enter the pass code 2007 HUSSMANN CORPORATION e BRIDGETON MO 63044 2483 U S A U S amp CANADA 1 800 504 4828 e WWW CHILLCHAMBER HUSSMANN COM MAXI 140 7 Defrosts The unit must go into defrost mode at least twice in each 24 hours to maintain optimal performance During defrost the temperature display may move up 2 3 F 1 2 C Avoid opening the door during the defrost cycle Defrost is necessary because the Chill Chamber operates at temperatures below freezing 22 F 5 5 C Defrosting is done automatically with Safe NET Defrost water drains to a drip pan where it evaporates Restricting airflow around the bottom of a Chill Chamber may delay or pr
6. e Replace any damaged power cord e Never turn off by pulling on the power cord e Unit must have electrical ground at all times e Never connect the ground wire directly to the neutral wire or connect to gas water telephone drain pipe lightning rod etc e Do not damage the refrigeration system e Do not use any mechanical device or other means to speed the defrost process except as recommended by the manufacturer e Unplug the Chill Chamber before cleaning e Do not store or use toxic or dangerous chemical products inside the case e Do not use electrical devices in the Chill Chamber unless recommended by the manufacturer e Use two or more people to move a unit e Keep packing materials away from children We reserve the right to change or revise specifications and product design in connection with any feature of our products Such changes do not entitle the buyer to corresponding changes improvements additions or replacements for equipment previously sold or shipped 2007 HUSSMANN CORPORATION e BRIDGETON MO 63044 2483 U S A U S amp CANADA 1 800 504 4828 e WWW CHILLCHAMBER HUSSMANN COM MAXI 140 1 Contact To request technical assistance with your Chill Chamber or to place a service call please phone Hussmann s call center at 1 800 504 4828 LOCATION Chill Chambers are designed for a protected environment out of direct sun or rain Placing the unit near heat sources ovens grills etc or i
7. grille Change Standard Defrost Time Pass Code Required Your business may need defrost times that are not evenly spaced or staggered such as 0300 3 00 a m and 1400 2 00 p m because your business is open later Or you may need more than two defrosts due to peak sales or high humidity 0300 0900 1500 and 2100 are evenly spaced while 0300 1000 2100 are staggered defrost times Safe NET can handle 2 or 3 staggered defrosts or 2 to 8 evenly spaced defrosts in 24 hours 2007 HUSSMANN CORPORATION e BRIDGETON MO 63044 2483 U S A U S amp CANADA 1 800 504 4828 e WWW CHILLCHAMBER HUSSMANN COM NDEF The ndEF parameter sets the number of defrost cycles in a 24 hour period The number works in conjunction with the StAr parameter discussed above The ndEF number of defrosts determines the number of defrosts that occur in a 24 hour period beginning with the StAr first defrost parameter The maximum number of defrosts allowed in a 24 hour period is 8 The defrosts are spaced evenly across the 24 hour period beginning with the StAr time The formula for calculating defrost start times 1s as follows Defrost interval 24 ndEF First defrost cycle start time StAr Second start time StAr Interval Third start time StAr 2 X Interval Eighth start time StAr 7 X Interval For example with a StAr value of 01 00 and an ndEF setting of 4 the defrost cycle start times are 1 00 A M 7 00 A M 1 00 P M
8. must be noted on the freight bill or express receipt and signed by the carrier s agent otherwise carrier may refuse claim Concealed Loss Or Damage When loss or damage is not apparent until after equipment is uncrated retain all packing mate rials and submit a written request to the carrier for inspection within 15 days IMPORTANT The MAXI 140 Chill Chamber must remain upright at all times Do not tilt more than 30 degrees from vertical at any time 2007 HUSSMANN CORPORATION e BRIDGETON MO 63044 2483 U S A U S amp CANADA 1 800 504 4828 e WWW CHILLCHAMBER HUSSMANN COM UNCRATE Use the appropriate equipment to safely lift and move the Chill Chamber to the preferred location in your business Carefully remove the shipping box Avoid scratching the Chill Chamber Recycle packing materials whenever possible Remove Shipping Legs so the MAXI 140 Chill Chamber base can be sealed to counter TE T SZ E T 3ES ZRRRRRRRRRRPPL Ren t Remove Shipping Legs e Front and Back d After leveling use field supplied FDA food grade silicone sealant to seal the gap between the base of the MAXI 140 and the countertop Examples of FDA food grade silicone sealant Permatex Inc Silicone RTV Sealant for Food Zone Henkel Loctite Corp RTV Silicone Adhesive Sealants for Food Zone Loctite Superflex Silicone Sealant for Food Zone Loctite Silatech General Electric Co RTV Silicone Rubber Adhe
9. 2483 U S A U S amp CANADA 1 800 504 4828 e WWW CHILLCHAMBER HUSSMANN COM e Unplug the unit before cleaning Clean the unit frequently to minimize odors and to main tain operating efficiency e Do not add warm product e Restocked product may freeze e Never place product on the bottom of unit e Place the lower removable shelf flush against the back to maintain proper air flow and product temperature e The unit must remain upright at all times Do not tilt more than 30 degrees from vertical at any time e The light switch is located on the top right side of the interior back wall e Maintain air flow around the unit at all times To obtain warranty information or other support contact your Hussmann representative 1 800 504 4828 Please include the model and serial number of the product Or go to Nttp chillchamber nussmann com serv warranty htm htip chillchamber hussmann com serv ChillChamberWarranty pdf P N 31033596_B 01 June 2007 P N 31033596_B 01 June 2007 TROUBLESHOOTING The following chart identifies most common problems their causes and suggested solutions MAXI 140 15 Troubleshooting Guide To place a service call please phone Hussmann s call center at 1 800 504 4826 Problem Possible Causes Solution Action Does not turn on Plug 1s out of outlet Insert plug into outlet Poor contact at outlet Remove and reinsert plug into outlet If good contact cann
10. ARRANTIES RECITED ABOVE ARE THE ONLY WARRANTIES EXPRESS IMPLIED OR STATUTORY MADE BY HUSSMANN WITH RESPECT TO ITS PRODUCTS INCLUDING ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS AND HUSSMANN NEITHER ASSUMES NOR AUTHORIZES ANY PERSON TO ASSUME FOR IT ANY OTHER OBLIGATION OR LIABILITY INCONNECTION WITH THE SALE OF ITS PRODUCTS OR ANY PART THEREOF THIS WARRANTY SHALL NOT APPLY TO LOSS OF FOOD OR CONTENTS OF THE PRODUCTS DUE TO FAILURE FOR ANY REASON HUSSMANN SHALL NOT BE LIABLE e For any repair or replacements made without the written consent of Hussmann or when the product is installed or operated in a manner contrary to the printed instructions covering installation and service which accompanied such product e For any damages delays or losses direct consequential incidental or otherwise which may arise in connection with such product or part thereof e For damages during shipment or caused by fire flood strikes or other circumstances beyond its control e When the product is subject to negligence abuse misuse or when the serial number of the product has been removed defaced or altered e When the product is operated on low or improper voltages e When the product is put to a use other than as recommended by Hussmann e When operation of the product is impaired due to improper drain installation e For payment of refrigerant loss for any reason other than on a self contained case e For costs related to shipping or hand
11. ATION Limited Warranty for Chill Chambers in the United States amp Canada This warranty is made to the original user at the original installation site and 1s not transferable BASIC WARRANTY Hussmann Chill Chambers are warranted to be free from defect in material and workmanship under normal use and service for twelve months Unless otherwise indicated this warranty 1s valid from the date of original installation not to exceed fifteen months from the date of shipment from the factory Except as otherwise specifically set forth Hussmann s obligation under this warranty shall be limited to repairing or exchanging any part or parts without charge FCA factory or nearest authorized parts depot Incoterms 2000 during the warranty period which is proven to the satisfaction of the warranty administration organization to be defective Hussmann or its designee reserves the right to inspect the jobsite installation and reason for failure Hussmann will also pay the cost of labor to install and or replace parts at prevailing straight time rates and repair times which are in accordance with industry standard repair times as administered by the warranty administration organization Hussmann s warranty covers the Chill Chamber and all its components except lamps driers fuses and other maintenance type replacement parts for the applicable warranty period Additionally for thirty six months from date of installation Hussmann warrants all sealed mu
12. U S A U S amp CANADA 1 800 504 4828 e WWW CHILLCHAMBER HUSSMANN COM e With hours flashing use the UP or DOWN button until the correct hour is displayed Safe NET uses a 24 hour or military clock where 12 is noon e Press SELECT and the clock has been set e The clock will automatically return to main display The internal real time clock will retain its time setting for at least one week 1f unplugged Important The clock does not automatically adjust for Daylight Saving Time If defrost times are critical the clock must be reset manually Settings Requiring Pass Code e Defrost Quantity e Time of Defrosts The pass code prevents inadvertent or unau thorized changes to the Safe NET controller Any change beyond setting the time clock will require the pass code Enter the Pass Code e Press the SELECT button top left button until you see StUP SEU e Then press the UP button once to get to PASS and press SELECT PRISIS P N 31033596 B 01 June 2007 P N 31033596_B 01 June 2007 e Once the display starts blinking you will be able to select the pass code 595 Press the DOWN button to get to this number WIER e Once 595 is displayed press the SELECT button on the Safe NET display module The display will revert to cycling between PASS and 595 This enables editing of system parameters The user may now navigate the menu system and edit parameters as necessary Note The pass code protected
13. ements A WARNING Do not use HOT water on COLD glass Surfaces This can cause the glass to shatter and could result in personal injury Allow the glass door to warm before applying hot water DO NOT USE AMMONIA BASED PRODUCTS TO CLEAN LIGHTED CANOPY NEVER USE ABRASIVE CLEANERS OR SCOURING PADS A WARNING To reduce the risk of fire electrical shock or injury when cleaning your Chill Chamber e Unplug the Chill Chamber before cleaning e Keep all liquids away from electrical and electronic components e Do not use any mechanical device or other means to speed the defrost process except as recommended by the manufac turer Exterior Surfaces The exterior surfaces must be cleaned with a soft cloth mild detergent and warm water to protect and maintain their attractive finish 2007 HUSSMANN CORPORATION e BRIDGETON MO 63044 2483 U S A U S amp CANADA 1 800 504 4828 e WWW CHILLCHAMBER HUSSMANN COM NEVER USE ABRASIVE CLEANERS OR SCOURING PADS NEVER USE CAUSTIC SODA ALCOHOL KEROSENE GASOLINE THINNER SOLVENTS DETERGENTS ACIDS CHEMICALS OR ABRASIVES Do NOT USE AMMONIA BASED CLEANERS ON ACRYLIC PARTS Interior Surfaces The interior surfaces may be cleaned with most domestic detergents ammonia based cleaners and sanitizing solutions with no harm to the surface Always read and follow the manufacturer s instructions when using any cleaning product Do NOT Use e Abrasive cleansers and scouring
14. event complete evaporation In the event of power loss the real time clock will keep its settings for at least one week once the battery is fully charged The real time clock battery is automatically recharged when the unit is plugged in The Chill Chamber Safe NET comes with two defrosts preset one at 0200 and one at 1400 If the preset defrost times are acceptable for your business no settings need to be changed Replace the Safe NET cover and grille If the preset times need to be changed for your business schedule or 1f additional defrosts are needed because the unit is in an extreme envi ronment the Safe NET controller can be set to meet the requirements of your business For MAXI 140 defrost the evaporator fan motor stops during defrost and WILL NOT came back on when the compressor kicks on because it has a delay in order to cool down the evaporator before blowing air again The fan delay is controlled by the temperature of the coil outlet GILL FARMER 8 MAXI 140 Set Defrost Time Pass Code Needed e Press the SELECT button top left button until you see dEFr DIE FIle e Then press the UP button twice to get to StAr and press SELECT SIE Alle e Press the UP or DOWN button to change minutes press SELECT e Press the UP or DOWN button to change hours press SELECT The second defrost will follow 12 hours later If this change meets the needs of your business replace the Safe NET cover and
15. king 2007 HUSSMANN CORPORATION e BRIDGETON MO 63044 2483 U S A U S amp CANADA 1 800 504 4828 e WWW CHILLCHAMBER HUSSMANN COM MAXI 140 9 LOADING 1 Add the maximum quantity 66 bottles allowed of Anheuser Busch aluminum bottles 2 Load the product after closing for the night so that it can pull down to temperature overnight 3 Stock bottles upright only 4 Do not add warm product during selling hours 5 If possible load just before or during defrost The LED display shows the calculated actual beer temperature based on sensor input The calculation requires beer to be loaded in the unit for 30 minutes to be accurate Estimated Pull Down Time to Achieve 22 F 5 5 C Optimum Temperature Pre Cooled Beer to 45 F 7 C Beer at 70 F 21 C Loading empty unit at 80 F 27 C outside temperature 8 5 hours approximate 15 hours approximate Loading half empty unit at 80 F 27 C outside temperature 13 hours approximate 7 hours approximate GILL GAME 10 MAXI 140 CARE AND CLEANING Long life and satisfactory performance of any equipment is dependent upon the care it receives To ensure long life proper sanitation and minimum maintenance costs this unit should be thoroughly cleaned all debris removed and the interiors washed down Cleaning often will control or eliminate odor buildup Frequency of cleaning is dependent on usage and local health requir
16. ling of replacement parts e For periodic maintenance items such as filters gaskets lamps fuses and driers e Diagnostic charges e To defend indemnify or hold harmless any purchaser or end user for any claims demands lawsuits or actions of any nature Hussmann Chill Chamber Warranty Page 2 of 2 25 January 2007 LHW
17. lti glass assemblies If within the warranty period it can be proven to the satisfaction of Hussmann s warranty administration organization that there 1s impaired visibility through a multi glass assembly caused by moisture between the glasses the multi glass assembly will be replaced free of charge excluding freight charges from the factory or nearest authorized parts depot This warranty excludes accident misuse or glass breakage For Chill Chamber motor compressors excluding capacitors and relays Hussmann agrees to repair or exchange at its option the original compressor unit only with a compressor of like or of similar design and capacity if it 1s shown to the satisfaction of Hussmann that the compressor 1s inoperative due to defects in factory workmanship or material under normal use and service as outlined in Hussmann s Owner s Manual which is shipped inside new Chill Chambers Hussmann s sole obligation under this paragraph shall be limited to five years from date of factory shipment and applies only to the compressor shipped from the factory with the new product After year one 1 no labor is included to replace the compressor EXTENDED WARRANTY Any warranty may be extended for an additional period not to exceed a total 60 months in combination with the basic warranty but must be purchased from Hussmann and documented with a paid invoice to be valid The extended warranty must be purchased and paid for prior to the expi
18. n direct sun will adversely affect performance Unusual ambient conditions can be handled by changing settings in the Safe NET controller Temperatures of 80 F 27 C and less than 55 R H are considered normal ambient conditions The merchandiser will not operate properly in environments of extreme temperature and humidity above 80 F 27 C and 55 relative humidity Performance issues resulting from poor local conditions are out of warranty The merchandiser must have a minimum 5 inch 13 cm ventilation space at the back on each side and below the door in front Top must be open Ia e a ABOVE 5 inch 13 cm Required Ventilation Minimum GILL FARMER 2 MAXI 140 Condensation may form on external parts when the merchandiser is used in high relative humidity Use a soft cloth to remove moisture The floor or counter must be flat to facilitate leveling and to avoid problems with door seal ing or abnormal noises The floor or counter must support the weight of a fully loaded Chill Chamber A fully loaded MAXI 140 weighs about 210 Ib 95 kg INSPECTION All equipment should be thoroughly examined for shipping damage before and during the unloading Each Chill Chamber is carefully inspected at our factory Any claim for loss or damage must be made to the carrier The carrier will provide any necessary inspection reports and or claim forms Apparent Loss Or Damage If there is an obvious loss or damage it
19. on the RH side Do NOT remove the other six shelf screws unless required by local health code Fixed Upper Shelf I S i i A 8 e A of yie RER WI 13 u vs A LS A Ee Pi T ei VG 33 e ns GEET MEET AAA a Ff oa r z z e EE E Fo be Shelf Fasteners rtitrtEESRRERE Ree HE TT UN Removable Lower Shelf with Product Stop to Rear 4 Pull the upper shelf OUT and then UP to clear screws and remove from the unit 5 Clean and sanitize the shelves and interior Dry completely before restoring power 6 Reinstall the upper shelf Make sure that each shelf mounting slot engages with its mounting screw 2007 HUSSMANN CORPORATION e BRIDGETON MO 63044 2483 U S A U S amp CANADA 1 800 504 4828 e WWW CHILLCHAMBER HUSSMANN COM MAXI 140 11 ET Remove Front Screws Holding Upper Shelf 7 Install the near most LH side and RH side screws into the upper shelf 8 Place the lower shelf flush against the back with the bottle rail toward the back of the Chill Chamber to maintain proper air flow and product temperature The lower shelf must be installed 9 After cleaning or servicing the Chill Chamber reconnect the electrical power Cleaning under the Unit Use a vacuum with a long wand attachment to remove accumulated dust and debris from under units with optional legs Units without optional legs are sealed at the base GILL GAME 12 MAXI 140 Condenser Coil To maintain
20. oosen the four hex head screws Just enough to allow the hinge to move backward which will tighten the door seal Top of MAXI 140 2 Loosen Screws P N 31033596_B 01 June 2007 P N 31033596_B 01 June 2007 SET Safe NET TIME Safe NET 1s the electronic controller that regulates the cooling system Before Safe NET can operate correctly the internal clock must be set This will allow it to regulate the system for defrost at convenient times of the day around your location s schedule when you are not at the busiest serving times The Chill Chamber s Safe NET comes preset with two defrosts per day In most situations this will be enough defrosts unless the unit is operated in non air conditioned environments or high humidity locations The Safe NET on the MAXI 140 is located behind the back grille below the condenser coil ut TE wg an ser Te 2007 HUSSMANN CORPORATION e BRIDGETON MO 63044 2483 U S A U S amp CANADA 1 800 504 4828 e WWW CHILLCHAMBER HUSSMANN COM MAXI 140 When you plug in the Chill Chamber you should see the text Safe NET scroll across the display e Open the Safe NET controller using a small flat blade screwdriver to pop off the oval cover this may be tight e Plug in the MAXI 140 Be careful of moving parts in the compressor compartment DOWN Button SELECT UP Button Button e You will see three buttons on the control board as sho
21. ot be established contact a licensed electrician to replace the outlet No power Power outage OR Circuit breaker tripped UNPLUG UNIT until power 1s restored UNPLUG UNIT until breaker is reset Safe NET controller settings are retained for at least five days but a power surge can cause damage Low Voltage Install a voltage regulator Unusual Noise Unit not level Reposition and level the unit Unit contacting structure Reposition unit to provide space on all sides Rear grille loose Fasten grille to attenuate sound Slow to cool product Dirty condenser coil Clean condenser coil Poor airflow around unit Reposition unit to provide space on all sides Evaporator blocked by ice Verify that door is sealing completely Heavy use in high humidity reset Safe NET controller to increase frequency of defrosts Loading with warm product The warmer the product when placed in the Chill Chamber the longer the time needed to cool the product Temperature display Recently stocked Allow time for temperature display to catch up not accurate with stocking about 30 minutes Condensation High relative humidity Remove moisture with soft cloth Reduce ambient on door humidity Move unit to area of lower humidity 2007 HUSSMANN CORPORATION e BRIDGETON MO 63044 2483 U S A U S amp CANADA 1 800 504 4828 e WWW CHILLCHAMBER HUSSMANN COM GT FMEER HUSSMANN CORPOR
22. pads as these will mar the finish e Coarse paper towels on coated glass e Ammonia based cleaners on acrylic parts e Solvent oil or acidic based cleaners on any interior surfaces e A hose on display or interior lights or any other electrical connection Do e First disconnect electrical power e Remove the product and all loose debris e Thoroughly clean all surfaces with soap and hot water DO NOT USE STEAM OR HIGH WATER PRESSURE HOSES TO WASH THE INTERIOR THESE WILL DESTROY THE UNIT SEALING CAUSING LEAKS AND POOR PERFORMANCE e Take care to minimize direct contact between fan motors and cleaning or rinse water e Rinse with hot water but do NOT flood e Allow the unit to dry before resuming operation e Wipe down lighted surfaces with a damp sponge or cloth so that water does not enter the light channel e After cleaning is completed turn on power to the Chill Chamber P N 31033596_B 01 June 2007 P N 31033596_B 01 June 2007 Whenever possible use all product before per forming maintenance Product allowed to warm above the operating temperature 22 F may freeze when restocked Removing Shelves The MAXI 140 comes standard with one fixed wire shelf upper with dividers for 160z aluminum bottles and one removable flat wire shelf lower 1 Disconnect the electrical power to the Chill Chamber 2 Lift out the lower shelf 3 To remove upper shelf remove the nearest screw on the LH side and
23. peak operating efficiency use a soft hand brush or soft brush attachment on a vacuum to remove accumulated dust from the coil at least once each month A dirty coil will slow product cooling significantly and can increase energy consumption by as much as 20 Consult an authorized technician 1f more extensive cleaning 1s needed LAMP REPLACEMENT BU 4440801 TS 8W Interior Lamp Fluorescent Canopy Display Lighting Fluorescent lamps must be replaced by lamps of the same size dimension and wattage as the original Always unplug unit before replacing lamp Restocked beer may freeze 1 Sell all product in the unit 2 Turn off lamp switch Unplug the unit 3 Remove shelves 4 Remove the two recessed screws from the canopy Screws are accessible through holes in the bottom of the canopy cover 2007 HUSSMANN CORPORATION e BRIDGETON MO 63044 2483 U S A U S amp CANADA 1 800 504 4828 e WWW CHILLCHAMBER HUSSMANN COM 5 Carefully remove the bottom canopy edge from the unit 6 Disconnect blue temperature display connector from the canopy aa e T runs E L fc d ST r L J i BW ol a a na r amp a a eu Temperature display connector 7 Carefully remove the canopy and set aside P N 31033596 B 01 June 2007 P N 31033596_B 01 June 2007 8 To remove the fluorescent lamp disconnect the two individual connectors from each end 9 Remove from holding clips 10 Re
24. place the lamp 11 Reassemble in reverse order 12 Plug the unit in Turn on light switch 13 Allow the unit to run for at least 30 minutes before stocking with fresh product LED interior Lighting LED light tube must be replaced by a light tube of the same size dimension and wattage as the original Always unplug unit before replacing LED light strip Restocked beer may freeze 1 Follow steps 1 through 7 of Fluorescent Lamp Replacement 2 Disconnect the LED connector 3 With a screwdriver loosen but do not remove the LED lighting bracket from one side only 2007 HUSSMANN CORPORATION e BRIDGETON MO 63044 2483 U S A U S amp CANADA 1 800 504 4828 e WWW CHILLCHAMBER HUSSMANN COM MAXI 140 13 4 Rotate loosened lighting bracket and remove LED light tube e j F r a V z n aa j m A be a d F f a i L Route electrical cord through here a a til A o NY Bracket Replacement LED tube GIE ee must be at same angle RS Eh 5 Replace by positioning the LED light tube with electrical wires to the right hand side closest to slot Do not wrap wires around the LED light tube Route the electrical wires through the slot before re connecting 6 Reassemble in reverse order 7 Plug the unit in Turn on light switch 8 Allow the unit to run for at least 30 minutes before stocking with fresh product GILL GAME 14 MAXI 140
25. ration of the basic warranty coverage The basic and extended warranties listed above do not include replacement or repair of controls relays capacitors or over load protectors Hussmann Chill Chamber Warranty Page 1 of 2 25 January 2007 PATENT WARRANTY Hussmann warrants that its products do not infringe the claims of any existing United States patent but Hussmann makes no warranty against infringement by reason of the use thereof either in combination with other products or in the operation of any process or use of products other than for their intended purpose This warranty is subject to purchaser promptly notifying Hussmann in the event of any action for such infringement brought against purchaser and permitting Hussmann to participate in the defense of such action Hussmann reserves the right to modify or replace any product alleged to constitute and infringement or to remove such product and refund the amount paid by purchaser therefor This warranty is not transferable The foregoing patent warranty shall not apply to any product or part thereof made to purchaser s design and as to such product or part Hussmann assumes no liability for patent infringement The foregoing states the entire liability of Hussmann with regard to patent infringement Any warranty repair made by Hussmann shall not extend the term of the warranty Any warranty claim must be made to Hussmann in writing within 45 days of the warranty repair date THE W
26. sive Sealant for Food Zone RTV 102 RTV 103 RTV 108 RTV 112 and others DOW Corning Corp 100 Silicone Sealant for Food Zone Dow Corning Commercial Grade Industrial Grade Silicone for Food Zone Dow Corning 700 RTV Silicone Sealant for Food Zone Dow Corning HVAC R P N 31033596_B 01 June 2007 P N 31033596_B MAXI 140 3 01 June 2007 Optional Leg Kit To maintain NSF standards of cleanability when sealing cannot be done Hussmann offers optional leg kits that raises the MAXI 140 four or six inches Directions are included with the optional leg kit IMPORTANT After leveling wait at least 30 minutes before turning on power to the Chill Chamber to allow any oil residue to return to the compressor Oil not in the compressor at start up may cause permanent damage not covered by warranty LEVEL Chill Chambers must be level front to back and side to side to operate at peak efficiency Electrical requirements for the merchandiser Shimming may be necessary Ensure all sides are stated on the serial plate attached to the are firmly supported Use care when shimming unit legs MAXI 140 1000 VA Nominal Minimum Maximum Voltage Voltage Voltage 120 108 132 If the power supply oscillates beyond the range given in the preceding table install a voltage regulator PLUG IN Put the Chill Chamber on its own dedicated Light Switch electrical circuit with ground 12AWG is the The MAXI
27. wn in this photo The SELECT button is used to scroll through menus and to edit confirm values Use the UP or DOWN button to move to the next item in the menu or change the value of a parameter Three Button Rules e Always start by pushing and releasing the SELECT button watch what is displayed Which menu are you in SUP CLOC DEFr tEM VALv DiSP and cycles back to StUP GALL GAME 6 MAXI 140 e Press and release the SELECT button until you are in the proper menu Once in the proper menu press the UP or DOWN button to enter the menu and to scroll through the menu e Once at the menu item that you want press the SELECT button until the item flashes between the value and the title You may have to press the SELECT button more than once to get the item to flash e Then press the UP or DOWN button to change the item e Remember to push the SELECT button to save the item e Pressing the UP and DOWN buttons at the same time acts as an escape to go back out of the menus Set the Clock e Press the UP and DOWN buttons at the same time to get to the temperature reading default display e Press the SELECT button until you see CLOC CLG e Press UP once then DOWN once and then SELECT eliza e With minutes flashing use the UP or DOWN button until the correct minutes are displayed then press SELECT Hours should flash lella 2007 HUSSMANN CORPORATION e BRIDGETON MO 63044 2483