1. Contact HP Service and Support for the following reasons To get the latest driver version firmware or BOOT BIOS for your HBA drivers If your HBA PCI cards are not listed in the table above If you update the HBA driver version firmware or BOOT BIOS reboot the system after the update before you continue STEP 2 Verify that the firmware version for the VA array is installed VA 7x10 Firmware Revision A140 VA 7x00 Firmware Revision HP22 Contact HP Service and Support to get the latest firmware version for your storage array If you update the firmware reboot the system after the update before you continue STEP 3 Install the multipath software SecurePath HP SecurePath version v4 0C To obtain HP StorageWorks SecurePath http www hp com go SecurePath Reboot the system after the software installation before you continue STEP 4 Connect the appropriate fiber cables to the HBA card s STEP 5 Install SecurePath Manager optional If you use SecurePath and want to install SecurePath Manager see Section 6 Section 5 MA Modular Array HSG 80 STEP 1 Verify that the FC HBA driver version firmware and Boot BIOS are installed EMA12000 EMA16000 SCSIPort 5 4 82a16 SCSIPort 5 4 82a16 SCSIPort 5 4 82a16 SCSIPort 5 4 82a16 MA8000 Firmware 3 92a2 Firmware 3 92a2 Firmware 3 92a2 Firmware 1 01a2 ESA12000 Boot Bios 1 70a1 Boot Bios 1 70a1 Boot Bios 1 70a1 Boot Bios 1 63al RA8000 EMA1
2. 92a2 Firmware 3 92a2 Firmware 1 90a4 Boot Bios 1 70al Boot Bios 1 70a1 Boot Bios 1 70a1 Boot Bios 1 70a1 EVA8000 SCSIPort 5 5 10a11 SCSIPort 5 5 10a11 SCSIPort 5 5 10a11 SCSIPort 5 5 10a11 StorPort 5 5 1 02a7 StorPort 5 5 1 02a7 StorPort 5 5 1 02a7 StorPort 5 5 1 02a7 EVA6000 4 EVA4000 Firmware 3 92a2 Firmware 3 92a2 Firmware 3 92a2 Firmware 1 90a4 Boot Bios 1 70al Boot Bios 1 70a1 Boot Bios 1 70al Boot Bios 1 70a1 SCSIPort 5 5 10a11 Boot Bios 1 70al Boot Bios 1 70a1 EVAS5000 StorPort 5 5 1 02a7 StorPort 9 0 2 16 StorPort 5 5 1 02a7 StorPort 5 5 1 02a7 EVA3000 Firmware 1 90a4 aie 1 45 Firmware 1 90a4 Firmware 1 90a4 Boot Bios 1 70al aa Boot Bios 1 70a1 Boot Bios 1 70 al EVA8000 SCSIPort 5 5 10a11 SCS Port 5 5 10a11 StorPort 5 5 1 02a7 SCSIPort 9 0 2 11 StorPort 5 5 1 02a7 EVA6000 Firmware 1 90a4 Firmware 1 34 Firmware 1 90a4 EVA4000 Ad 7 aa The above table shows the latest driver firmware Boot Bios for the supported FC HBAs Check the HP web site http www hp com go eva for the updates Note Windows Storage Server 2003 R2 and Windows 2003 32 bit are identical for the purpose of this compatibility table Contact HP Service and Support for the following reasons To get the latest driver version firmware or BOOT BIOS for your HBA drivers If your HBA PCI cards are not listed in the table above If you update the HBA driver version firmware or BOO
3. MSA1000 MSA1500 v1 10 If you have a NAS system unit configured for high availability install MultiPath Input Output MPIO software Currently two software MPIOs are supported for these storage arrays HP StorageWorks SecurePath and HP MPIO DSM To obtain HP StorageWorks SecurePath http www hp com go SecurePath Do not install the AutoPath driver when prompted during installation Reboot the system after the software installation before you continue HP MPIO users can install the software located at http h18006 www1 hp com products sanworks multipathoptions index html IMPORTANT Review MPIO documentation readme installation instructions Review important information pertaining to the HP MPIO DSM prerequisites system requirements important notes and considerations before you begin the installation process STEP 4 Connect the appropriate fiber cables to the HBA card s STEP 5 Install SecurePath Manager optional If you use SecurePath and want to install SecurePath Manager see Section 6 Section 2 EVA Enterprise Virtual Array STEP 1 Verify that the FC HBA driver version firmware and Boot BIOS are installed SCSIPort 5 5 10a11 SCS Port 9 0 2 11 SCSIPort 5 5 10a11 SCSIPort 5 5 10a11 SCSIPort 5 5 10a11 SCSIPort 5 5 10a11 SCSIPort 5 5 10a11 EVA5000 StorPort 5 5 1 02a7 StorPort 5 5 1 02a7 StorPort 5 5 1 02a7 StorPort 5 5 1 02a7 EVA3000 Firmware 3 92a2 Firmware 3
4. 2000 EMA16000 SCSIPort 5 4 82a16 MA8000 Firmware 1 01a2 ai ee es ESA12000 Boot Bios 1 52a1 peewee d RA8000 The above table shows the latest driver firmware Boot Bios for the supported FC HBAs Check the HP web site http www hp com for updates Note Windows Storage Server 2003 R2 and Windows 2003 32 bit are identical for the purpose of this compatibility table Contact HP Service and Support for the following reasons To get the latest driver version firmware or BOOT BIOS for your HBA drivers If your HBA PCI cards are not listed in the table above If you update the HBA driver version firmware or BOOT BIOS reboot the system after the update before you continue STEP 2 Verify that the firmware version for the HSG 80 array is installed HSG 80 Firmware Revision ACS 8 8 2 Contact HP Service and Support to get the latest firmware version for your storage array If you update the firmware reboot the system after the update before you continue STEP 3 Install the MA platform kit Install the MA platform kit located at Cipnas components SANConnect MA_PlatformKi ACS88WinKit e Multibus Switch o Ifyou are connecting your multibus MA storage array to a fibre switch select the Multibus Switch option during installation e Multibus Hub loop o Ifyou are connecting your multibus MA storage array to a fibre hub select the Multibus Hub loop option during installation o You MUST enter a unique arbitrated loop IP add
5. HP ProLiant Storage Server SAN Connection and Management Connecting to a SAN The instructions below are an aid to customers connecting to their Storage Area Network SAN Check the HP web site at http www hp com for any possible updates to the SAN Connection and Management documentation prior to executing instructions from this guide The latest updates to the HP SAN Design Guide are available on the HP web site at http h18006 www1 hp com storage saninfrastructure html Important HP strongly recommends that you install the software components before you connect fiber cables to the storage server Specific steps for proper connection to a SAN are based upon the Fibre Channel FC array to which the storage server will be attached The basic steps are as follows 1 Verify and update if needed the BIOS firmware driver for your FC HBA FCA2404 FCA2214 and so on 2 Verify and update if needed the firmware of the FC array 3 Install Multipathing software 4 Connect FC cables 5 Present Logical Unit Numbers LUNs to the storage server Quick links Click the section for your FC array type e Section 1 MSA Modular SAN Array e Section 2 EVA Enterprise Virtual Array e Section 3 XP Disk Array XP e Section 4 VA Virtual Array e Section 5 MA Modular Array HSG 80 Section 1 MSA Modular SAN Array STEP 1 Verify that the FC HBA driver version firmware and Boot BIOS
6. T BIOS is required be sure to reboot the system after the update before you continue STEP 2 Verify that the firmware version for the EVA array is installed EVA 3000 5000 Firmware Revision 3 028 or 4 001 EVA 4000 6000 8000 Firmware Revision 5 030 Contact HP Service and Support to get the latest firmware version for your storage array If you update the firmware reboot the system after the update before you continue STEP 4 Install the multipath software SecurePath or HP MPIO DSM HP SecurePath version v4 0C SP1 1 EVA3000 5000 only HP MPIO version Basic DSM for Windows for EVA3000 5000 for VCS 3 xxx v1 01 Full Featured DSM for Windows for EVA3000 5000 for VCS 4 xxx v1 00 00 Full Featured DSM for Windows for EVA4000 6000 8000 VCS 5 xxx v1 00 02 Windows with EVA storage requires the installation of HP StorageWorks multipathing software on each host to achieve high availability multiple path capability To obtain HP StorageWorks SecurePath http www hp com go SecurePath Do not install the AutoPath driver when prompted during installation Reboot the system after you install the software you continue HP MPIO users can install the software located at http h18006 www1 hp com products sanworks multipathoptions index html IMPORTANT Review MPIO documentation readme installation instructions Review important information pertaining to the HP MPIO DSM prerequisites system requirements important notes and considera
7. are installed Windows Storage Driver 5 5 10a10 Driver 9 0 0 13 Driver 5 5 10a10 Driver 5 5 10a10 Driver 5 5 10a10 Server 2003 R2 Firmware 3 92a2 Firmware 1 34 Firmware 1 90a4 Firmware 1 90a4 Firmware 3 92a2 Boot Bios 1 70al Boot Bios NA Boot Bios 1 70al Boot Bios 1 70al Boot Bios 1 70al The above table shows the latest Driver Firmware Boot Bios for the supported FC HBAs Check the HP web site http www hp com go msa for updates to these revisions Note Windows Storage Server 2003 R2 and Windows 2003 32 bit are identical for the purpose of this compatibility table Contact HP Service and Support for the following reasons To get the latest driver version firmware or BOOT BIOS for HBA drivers If your HBA PCI cards are not listed in the table above If you update the HBA driver version firmware or BOOT BIOS be sure to reboot the system after the update before you continue STEP 2 Verify that the firmware version for the MSA array is installed MSA1500cs Firmware revision 5 02 MSA1000 Firmware revision 4 48 Download the firmware for free at http www hp com go msa Contact HP Service and Support to get the latest firmware version for their storage array If you update the firmware be sure to reboot the system after the update before you continue STEP 3 Install the multipath software SecurePath or HP MPIO DSM HP SecurePath version v4 0C SP1 1 HP MPIO version Basic DSM for Windows for
8. gement capability for cross platform Secure Path configurations This application displays a graphical representation of multiple path configurations indicating the status of a user defined set of hosts storage systems and paths SPM runs on web based clients that support Sun Java 2 Runtime environment JRE Version 1 3 1 or later To obtain HP StorageWorks SecurePath http www hp com go SecurePath Important Currently HP NAS only supports SecurePath Manager SPM version 4 0C or later If you have older SPM versions contact HP Service and Support and upgrade if you want to use SPM on your NAS system HP Insight Manager must be installed for administrators to use SecurePath Manager SPM can be accessed on web based clients that have Sun Java 2 Runtime Environment JRE version 1 3 1 or later installed Expand Storage in a SAN environment Expansion is the process of adding physical disks to an array that has already been configured The logical drives or volumes that exist in the array before the expansion takes place are unchanged because only the amount of free space in the array changes The expansion process is entirely independent of the operating system Note See your storage array hardware user documentation for further details about expanding storage on the array Expand storage for MSA storage arrays The Array Configuration Utility enables online capacity expansion of the array and logical drive for
9. gned drive must also have a capacity no less than that of a drive in an existing array If these conditions are not fulfilled install at least one suitable drive on the controller and then click Refresh Add storage scenarios Smart Array storage arrays only e Add an unassigned physical disk to the array e Add anew disk to the appropriate storage device For information use the ACU online Help or the procedures to Expand Array in the Array Configuration Utility User Guide Expand logical drive This option in the ACU increases the storage capacity of a logical drive by adding unused space on an array to the logical drive on the same array The unused space is obtained either by expanding an array or by deleting another logical drive on the same array Add storage scenarios Smart Array storage arrays only e Extend an existing storage LUN where space is available in the array e Extend an existing storage LUN where space is not available in the array Smart Array only For information use the ACU online Help or the procedures to Extend logical drive in the Array Configuration Utility User Guide Expand storage for EVA storage arrays single node environment Presenting a virtual disk offers its storage to a host To make a virtual disk available to a host you must present it You can present a virtual disk to a host during or after virtual disk creation The virtual disk must be completely created before the host presen
10. he latest driver firmware Boot Bios for the supported FC HBAs Check the HP web site http www hp com for updates Note Windows Storage Server 2003 R2 and Windows 2003 32 bit are identical for the purpose of this compatibility table Contact HP Service and Support for the following reasons To get the latest driver version firmware or BOOT BIOS for your HBA drivers If your HBA PCI cards are not listed in the table above If you update the HBA driver version firmware or BOOT BIOS reboot the system after the update before you continue STEP 2 Verify that the firmware version for the XP array is installed XP 128 1024 Firmware Revision 21 12 02 00 00 XP 12000 Firmware Revision 50 04 31 00 00 Contact HP Service and Support to get the latest firmware version for your storage array If you update the firmware reboot the system after the update before you continue STEP 3 Install the multipath software SecurePath or HP MPIO DSM HP SecurePath version v4 0C SP1 V4 0C SP2 1 HP MPIO version Full Featured DSM for Windows for XP v1 00 01 Windows with XP storage requires the installation of HP StorageWorks multipathing software on each host to achieve high availability multiple path capability To obtain HP StorageWorks SecurePath http www hp com go SecurePath Reboot the system after you install the software before you continue HP MPIO users can install the software located at http h18006 www1 hp com products
11. ress for each adapter e Transparent Switch o Ifyou are connecting your transparent MA storage array to a fibre switch select the Transparent Switch option during installation e Transparent Hub loop o Ifyou are connecting your transparent MA storage array to a fibre hub select the Transparent Hub loop option during installation o You MUST enter a unique arbitrated loop IP address for each adapter e Extended Configuration o Select Extended Configuration during installation if you have an Extended Configuration for your back end storage array An extended configuration should be selected when five or more Window Servers have exclusive access to the same RAID arrays e HS Service o Select HS Service during installation if you require logging environmental changes within your storage system in the Windows Application Event Log STEP 4 Install the Multipath software SecurePath HP SecurePath version v4 0C SP2 To obtain HP StorageWorks SecurePath http www hp com go SecurePath Do not install the AutoPath driver when prompted during installation Reboot the system after the software installation before you continue STEP 5 Connect the appropriate fiber cables to their respective HBA card s STEP 6 Install SecurePath Manager optional If you use SecurePath and want to install SecurePath Manager see Section 6 Section 6 SecurePath Manager Optional Secure Path Manager SPM provides web based mana
12. sanworks multipathoptions index html IMPORTANT Review MPIO documentation readme installation instructions Review important information pertaining to the HP MPIO DSM prerequisites system requirements important notes and considerations before you begin the installation process For all XP storage arrays you must install MultiPath Input Output MPIO software Currently two software MPIOs are supported for these storage arrays HP StorageWorks SecurePath and HP MPIO DSM STEP 4 Connect the appropriate fiber cables to the HBA card s STEP 5 Install SecurePath Manager optional If you use SecurePath and want to install SecurePath Manager see Section 6 Section 4 VA Virtual Array STEP 1 Verify that the FC HBA driver version firmware and Boot BIOS are installed VA7x10 VA7x00 SCSIPort 5 4 82a16 Firmware 3 92a2 Boot Bios 1 63al SCSIPort 5 5 10 a11 Firmware 3 92a2 Boot Bios 1 70a1 SCSIPort 5 5 10 a11 Firmware 3 92a2 Boot Bios 1 70a1 SCSIPort 5 5 10 a11 Firmware 1 90a4 Boot Bios 1 70a1 SCSI Port 5 5 10 al 1 Firmware 1 90a4 Boot Bios 1 70a1 VA7x10 VA7x00 SCSIPort 9 0 2 11 Firmware 1 45 The above table shows the latest driver firmware Boot Bios for the supported FC HBAs Check the HP web site http www hp com for updates Note Windows Storage Server 2003 R2 and Windows 2003 32 bit are identical for the purpose of this compatibility table
13. shared disk http support microsoft com default aspx scid kb en us 304736 e How to replace a disk that is in a cluster and use of the Cluster Recovery utility http support microsoft com kb 305793 12
14. specific MSA storage arrays such as the MSA1000 and MSA1500 Expand array Expanding an existing LUN is accomplished using the storage array configuration software applicable to the storage array in use In the case of the Smart Array controller this is accomplished using the Array Configuration Utility LUN expansion may occur in disk arrays where space is available If insufficient space is available additional physical disks may be added to the array dynamically IMPORTANT An array expansion logical drive extension takes about 15 minutes per gigabyte or considerably longer if the controller does not have a battery backed cache While this process is occurring no other expansion or extension can occur simultaneously on the same controller Figure 1 Expanding a LUN Smart Array only https 16 100 209 210 2381 ACU XE ACU htm Microsoft Internet Explorer CA Array Configuration Utility 6 40 11 0 POCRASEON invent Configure f a Configuration view sical Vie Siha ska may be atically adjusted edde performance Bi is Smart Array 5i Controller in Embedded Slot NR Aea a Array A ee Systems do not support neni Cie pair tee 502GB g Logical Drive 1 27555 MB RAID 1 0 m me 261116 MB max E Logical Drive 2 7171 MB RAID 1 0 OK Cancel Unused Space 405028 MB 10 Note The Expand Array task is listed only if there is an unassigned physical drive on the controller The unassi
15. tation can occur If you choose host presentation during virtual disk creation the management agent cannot complete any other task until that virtual disk is created and presented Therefore HP recommends that you wait until a virtual disk is created before presenting it to a host To extend a virtual disk single node environment 1 Using HP StorageWorks Storage Management Appliance SMA or Command View EVA hosted on a server create or extend the virtual disk presented to the storage server 2 On the storage server open Device Manager right click the EVA LUN and Scan for hardware changes 3 Open command prompt and run DiskPart exe 4 List the current volumes of the system List Volumes 5 Select the volume to be extended select volume X 11 6 Extend the volume extend size n size is optional 7 Extend a LUN for EVA storage arrays clustered environment To extend a LUN on an EVA storage array in a cluster 1 Review requirements and procedures from the storage array hardware provider for expanding or extending storage 2 Ensure that Microsoft Windows Server 2003 SP1 is installed 3 Run Command View EVA on the storage server to increase the size of the presented EVA LUN 4 Run Microsoft DiskPart exe to add the additional space to the volume For additional information associated with extending a LUN in a cluster see the following Microsoft KB articles e How to extend the partition of a cluster
16. tions before you begin the installation process STEP 5 Connect the appropriate fiber cables to the HBA card s STEP 6 Install SecurePath Manager optional If you use SecurePath and want to install SecurePath Manager see Section 6 Section 3 XP Disk Array XP STEP 1 Verify that the FC HBA driver version firmware and Boot BIOS are installed SCSIPort 5 5 20a9 SCSIPort 5 5 20a9 SCSIPort 5 5 20a9 SCSIPort 5 5 20a9 Firmware 3 93a0 Boot Bios 1 70a3 SCSIPort 5 5 20a9 Firmware 3 93a0 Boot Bios 1 70a3 SCS Port 9 0 2 11 Firmware 3 93a0 Boot Bios 1 70a3 SCSIPort 5 5 20a9 XP128 StorPort 5 5 1 11a0 StorPort 5 5 1 11a0 StorPort 5 5 1 11a0 StorPort 5 5 1 11a0 XP1024 Firmware 3 93a0 Firmware 3 93a0 Firmware 3 93a0 Firmware 1 91lal Boot Bios 1 70a3 Boot Bios 1 70a3 Boot Bios 1 70a3 Boot Bios 1 70a3 SCSIPort 5 5 20a9 SCSIPort 5 5 20a9 SCSIPort 5 5 20a9 SCSIPort 5 5 20a9 XP12000 StorPort 5 5 1 11a0 StorPort 5 5 1 11a0 StorPort 5 5 1 11a0 StorPort 5 5 1 11a0 Firmware 1 9lal Boot Bios 1 70a3 Firmware 1 9lal Boot Bios 1 70a3 Firmware 1 45 XP128 StorPort 5 5 1 11a0 StorPort 9 0 2 16 StorPort 5 5 1 11a0 XP1024 Firmware 1 91lal ea Seli e 1 45 Firmware 1 91lal Boot Bios 1 70a3 mee ee Boot Bios 1 70a3 Sessa ses soan Sih 5520 XP12000 a StorPort 9 0 2 16 i Firmware 1 9lal Boot Bios 1 70a3 The above table shows t

Download Pdf Manuals

image

Related Search

Related Contents

AUE 651 031 AUE 651 033 AUE 651 035 AUE 651 032 AUE 651  American Dryer Corp. AD-78 II User's Manual  Dataram 32GB DDR4-2133  Descripción del proceso  CPS-200  Case Installation Manual For the IN-8  Philips AVENT SCF251  azur 540C/640C V2.0  Tutorial: 3D Pipe Junction Using Hexa Meshing  Frequently Asked Questions  