Home
HP DL380 User's Guide
Contents
1. Event identifier cpqnimsg dll 274 Hex 0x84350112 Service Event Log Severity Warning 2 Log Message The NIC Management Agent cannot generate Traps due to a communication problem with the NIC SNMP extension agent Event identifier cpqnimsg dll 275 Hex 0x44350113 Service Event Log Severity Information 1 Log Message Communication with the NIC SNMP extension agent has been restored TRAPS can now be sent Event identifier cpqnimsg dll 276 Hex 0x84350114 Service Event Log Severity Warning 2 Log Message The NIC Management Agent cannot communicate with the Token Ring Protocol driver CNMPROT SYS Event identifier cpqnimsg dll 277 Hex 0x44350115 Service Event Log Severity Information 1 Log Message The NIC Management Agent version 1 has started Event identifier cpqnimsg dll 279 Hex 0x84350117 Service Event Log Severity Warning 2 Log Message The NIC Management Agent could not set an event The data contain the error code Event identifier cpqnimsg dll 280 Hex 0x84350118 Service Event Log Severity Warning 2 Log Message The NIC Management Agent service could not start any agents successfully Event identifier cpqnimsg dll 281 Hex 0x84350119 Service Event Log Severity Warning 2 Log Message The NIC Management Agent main thread did not terminate properly The data contain the error code Event identifier cpqnimsg dll 283 Hex 0x843501 1b Service Event Log Severi
2. Event identifier cpqstmsg dll 261 Hex 0x84350105 Service Event Log Severity Warning 2 Log Message The Storage Agents service could not open registry key 1 The data contains the error code Event identifier cpqstmsg dll 262 Hex 0x84350106 Service Event Log Severity Warning 2 Log Message The Storage Agents service could not start any agents successfully Event identifier cpqstmsg dll 263 Hex 0x84350107 Service Event Log Severity Warning 2 Log Message The Storage Agents service could not read the registry value 1 The data contains the error code Storage agents 29 Event identifier cpqstmsg dll 264 Hex 0x84350108 Service Event Log Severity Warning 2 Log Message The Storage Agents service could not load the module 1 The data contains the error code Event identifier cpqstmsg dll 265 Hex 0x84350109 Service Event Log Severity Warning 2 Log Message The Storage Agents service could get the control function for module 1 The data contains the error code Event identifier cpqstmsg dll 267 Hex 0x8435010b Service Event Log Severity Warning 2 Log Message The Storage Agents service could not start agent 1 The data contains the error code Event identifier cpqstmsg dll 268 Hex 0x8435010c Service Event Log Severity Warning 2 Log Message The Storage Agents service detected an invalid state for agent 1 The data contains t
3. This error can be caused by a corrupt registry or a low memory condition Rebooting the server may correct this error Event identifier coqhsmsg dll 3845 Hex 0x84350f05 Service Event Log Severity Warning 2 Log Message Could not write the registry sub key 1 This error can be caused by a corrupt registry or a low memory condition Rebooting the server may correct this error Event identifier cpqhsmsg dll 3855 Hex 0x84350f0f Service Event Log Severity Warning 2 Log Message Could not open a cluster enumeration object The Cluster service may not be running Try to restart the Cluster service Event identifier cpqhsmsg dll 3856 Hex 0x84350f10 Service Event Foundation agents 22 Log Severity Warning 2 Log Message Could not enumerate all of the nodes in the cluster The data contains the error code Event identifier cpqhsmsg dll 3857 Hex 0x84350f11 Service Event Log Severity Warning 2 Log Message Could not get the cluster s status The Cluster service may not be running Try to restart the Cluster service Event identifier coqhsmsg dll 3858 Hex 0x84350f12 Service Event Log Severity Warning 2 Log Message Could not open the enumerated resource The Cluster service may not be running Try to restart the Cluster service Event identifier cpqhsmsg dll 3859 Hex 0x84350f13 Service Event Log Severity Warning 2 Log Message Could not enumerate the cluster s resources The
4. Event identifier coqhsmsg dll 3874 Hex 0x84350f22 Service Event Log Severity Warning 2 Log Message Could not read the registry sub key 1 This error can be caused by a corrupt registry or a low memory condition Rebooting the server may correct this error Event identifier cpqhsmsg dll 3875 Hex 0x84350f23 Service Event Log Severity Warning 2 Log Message Could not open enumerated network The Cluster service may not be running Try to restart the Cluster service Event identifier coqhsmsg dll 3876 Hex 0x84350f24 Service Event Log Severity Warning 2 Foundation agents 24 Log Message Could not enumerate the cluster s networks The Cluster service may not be running Try to restart the Cluster service Event Identifiers 4352 4626 Event identifier cpoqhsmsg dll 4352 Hex 0x84351100 Service Event Log Severity Warning 2 Log Message The External Status MIB Agent could not allocate memory The data contains the error code Event identifier coqhsmsg dll 4353 Hex 0x84351101 Service Event Log Severity Warning 2 Log Message The External Status MIB Agent could not open the base of the registry The data contains the error code Event identifier cpqhsmsg dll 4354 Hex 0x84351102 Service Event Log Severity Warning 2 Log Message 1 The data contains the error code Event identifier cpqhsmsg dll 4355 Hex 0x84351103 Service Event Log Severity Warning 2 Log M
5. NT Event ID 1067 Hex 0xc435042b cpqstmsg dll Log Severity Error 3 Event Title Drive Array Accelerator Battery Failed Log Message The array accelerator board attached to the array controller in slot 4 is reporting a battery failure SNMP Trap cpqDa5AccelBatteryFailed 3027 in CPQIDA MIB Symptom Accelerator Board Battery Failed This trap indicates that the agent has detected a battery failure associated with the array accelerator cache board User Action Replace the Accelerator Cache Board Supporting SNMP Trap Data sysName e cpqHoTrapFlags e cpqDaCntlrSlot e cpqDaCntlrModel e cpqDaAccelSerialNumber e cpqDaAccelTotalMemory Storage agents 35 Supporting SNMP Trap Description Battery status is failed NT Event ID 1068 Hex 0xc435042c cpqstmsg dll Log Severity Error 3 Event Title SCSI Controller Status Change Log Message The SCSI controller in slot 4 SCSI bus 5 has a new status of 2 SNMP Trap cpqScsi3CntlrStatusChange 5005 in CPQSCSI MIB Symptom SCSI Controller Status Change The Insight Agent has detected a change in the controller status of a SCSI Controller The variable cpqScsiCntlrStatus indicates the current controller status Supporting SNMP Trap Data e sysName e cpqHoTrapFlags e cpqScsiCntlrStatus Supporting SNMP Trap Description Status is now cpqScsiCntlrStatus NT Event ID 1069 Hex 0xc435042d cpqstmsg dll Log Severity Error 3 Event Ti
6. Supporting SNMP Trap Description Power subsystem DC power problem in enclosure cpqRackCommonEnclosureName in rack cpqRackName NT Event ID 1174 Hex 0x84350496 cpqsvmsg dll Log Severity Warning 2 Event Title Power Subsystem Facility AC Power Problem Log Message The AC facility input power has been exceeded for this power enclosure SNMP Trap cpqRackPowerChassisAcFacilityPowerExceeded 22032 in CPQRACK MIB Symptom Power subsystem AC facility input power exceeded for this power enclosure User Action Check the power enclosure and power supplies Replace any failed or degraded power supplies Supporting SNMP Trap Data e sysName e cpqHoTrapFlags e cpqRackName e cpqRackUid e cpqRackCommonEnclosureName e cpqRackCommonEnclosureSerialNum e cpqRackCommonEnclosureSparePartNumber e cpqRackCommonEnclosureTrapSequenceNum Supporting SNMP Trap Description Power subsystem AC facility input power exceeded in enclosure cpqRackCommonEnclosureName in rack cpqRackName NT Event ID 1175 Hex 0x84350497 cpqsvmsg dll Log Severity Warning 2 Event Title Power Subsystem Unknown Power Consumption Log Message There is an unknown power consumer drawing power SNMP Trap cpqRackPowerUnknownPowerConsumption 22033 in CPQRACK MIB Symptom Unknown power consumption There is an unknown power consumer drawing power User Action Check the power enclosure and power supplies Replace any
7. cpgFcTapeCntlhWWN e cpgFcTapeLibraryScsiBus e cpqFcTapeLibraryScsiTarget e cpqFcTapeLibraryScsiLun e cpgFcTapeLibraryStatus Supporting SNMP Trap Description Status is now cpqFcTapeLibraryStatus for the tape library NT Event ID 1175 Hex 0x84350497 cpqstmsg dll Log Severity Warning 2 Event Title Fibre Channel Tape Library Door Status Change Log Message The Fibre Channel tape library on tape controller with world wide name 4 SCSI bus 5 SCSI target 6 has a new door status of 7 SNMP Trap cpgFcTapeLibraryDoorStatusChange 16010 in CPQFCA MIB Symptom Fibre Channel Tape Library Door Status Change This trap indicates that the agent has detected a change in the door status of a Fiber Channel Tape library The variable Storage agents 51 cpqFcTapeLibraryDoorStatus indicates the current tape library door status The variable cpqFcTapelibraryScsiTarget indicates the SCSI ID of the tape library User Action If the tape library door is open close the tape library door Supporting SNMP Trap Data e sysName e cpqHoTrapFlags e cpgFcTapeCntlhWWN e cpqFcTapeLibraryScsiBus e cpqFcTapelibraryScsiTarget e cpqFcTapelibraryScsiLun e cpqFcTapeLibraryDoorStatus Supporting SNMP Trap Description The door is cpqFcTapeLibraryDoorStatus for tape library NT Event ID 1176 Hex 0x84350498 cpqstmsg dil Log Severity Warning 2 Event Title Fibre Channel Tape Drive Status
8. 2 Log Message The External Status MIB Agent got an unexpected error code while waiting for an event The data contains the error code Event identifier cpqhsmsg dll 4363 Hex 0x8435110b Service Event Log Severity Warning 2 Log Message The External Status MIB Agent did not respond to a request The data contains the error code Event identifier coqhsmsg dll 4364 Hex 0x8435 1 10c Service Event Log Severity Warning 2 Log Message The External Status MIB Agent received an unknown action code from the service The data contains the action code Event identifier cpqhsmsg dll 4365 Hex 0x84351 10d Service Event Log Severity Warning 2 Log Message The External Status MIB Agent could not get the system type The data contains the error code Event identifier coqhsmsg dll 4402 Hex 0x84351132 Service Event Log Severity Warning 2 Log Message The External Status MIB Agent could not create an SNMP session The data contains the error code Event identifier cpqhsmsg dll 4403 Hex 0x84351133 Service Event Log Severity Warning 2 Log Message The External Status MIB Agent SNMP request failed The data contains the error code Action Complete the following steps 1 Be sure that the SNMP service is configured to allow SNMP requests from localhost 2 Be sure that there is an adequate amount of free memory Event identifier coqhsmsg dll 4405 Hex 0x84351135 Service Event Log Severity Wa
9. 4 has a new status of 2 SNMP Trap cpqDa AccelStatusChange 3038 in CPQIDA MIB Symptom Accelerator Board Status Change This trap indicates that the agent has detected a change in the status of an array accelerator cache board The current status is represented by the variable cpqDaAccelStatus User Action If the accelerator board status is permDisabled 5 you may need to replace the accelerator board Supporting SNMP Trap Data e sysName e cpqHoTrapFlags e cpqDaCntlrHwLocation e cpqDaCntlrModel e cpqDaAccelCntlrindex e cpqDaAccelSerialNumber e cpqDaAccelTotalMemory e cpqDaAccelStatus e cpqDaAccelErrCode Supporting SNMP Trap Description Status is now cpqDaAccelStatus NT Event ID 1205 Hex 0x843504b5 cpqstmsg dll Log Severity Warning 2 Storage agents 66 Event Title Drive Array Accelerator Bad Data Log Message The array accelerator board attached to the array controller in 4 is reporting that it contains bad cached data SNMP Trap cpqDa AccelBadDataTrap 3039 in CPQIDA MIB Symptom Accelerator Board Bad Data This trap indicates that the agent has detected an array accelerator cache board that has lost battery power If data was being stored in the accelerator cache memory when the server lost power that data has been lost User Action Verify that no data has been lost Supporting SNMP Trap Data e sysName e cpqHoTrapFlags e cpqDaCntlrHwLocation e cpqDaCntlrMo
10. Log Severity Warning 2 Log Message Unable to allocate memory This indicates a low memory condition Rebooting the system will correct this error Event identifier cpqnimsg dll 258 Hex 0x84350102 Service Event Log Severity Warning 2 Log Message The NIC Management Agent could not register with the Service Control Manager The data contain the error code Event identifier cpqnimsg dll 259 Hex 0x84350103 Service Event Log Severity Warning 2 Log Message The NIC Management Agent could not set the service status with the Service Control Manager The data contain the error code Event identifier cpqnimsg dll 260 Hex 0x84350104 Service Event Log Severity Warning 2 Log Message The NIC Management Agent could not start the Service Control Dispatcher The data contain the error code Event identifier cpqnimsg dll 261 Hex 0x84350105 Service Event Log Severity Warning 2 Log Message Unable to read from the registry This error can be caused by a corrupt registry or a low memory condition Rebooting the server may correct this error Event identifier cpqnimsg dll 262 Hex 0x84350106 Service Event Log Severity Warning 2 Log Message Could not create the registry key 1 This error can be caused by a corrupt registry or a low memory condition Rebooting the server may correct this error Event identifier cpqnimsg dll 263 Hex 0x84350107 Service Event Log Severity Warning 2 Lo
11. Riser cpqHeResMem2BoardRiserNum NT Event ID 1039 Hex 0x8435040FL cpqsvmsg dll Log Severity Warning 3 Log Message The Advanced Memory Protection sub system has detected a memory fault The LockStep recovery engine has been activated For instruction on replacing the faulty memory see the server documentation SNMP Trap cpqHeResilientMemLockStepMemoryEngaged 6068 in CPQHLTH MIB Symptom Advanced Memory Protection LockStep Engine Memory Engaged The Advanced Memory Protection subsystem has detected a memory fault The LockStep engine has been activated User Action Replace the faulty memory Supporting SNMP Trap Data e sysName e cpqHoTrapFlags Supporting SNMP Trap Description The Advanced Memory Protection subsystem has engaged the LockStep memory NT Event ID 1072 Hex 0x84350430 cpqsvmsg dll Log Severity Warning 2 Log Message The frequency of memory errors is high enough such that tracking of correctable memory errors has been temporarily disabled SNMP Trap cpqHe3CorrectableMemoryLogDisabled 6016 in CPQHLTH MIB Symptom Correctable memory error tracking disabled The frequency of errors is so high that the error tracking logic has been temporarily disabled The cpqHeCorrMemLogStatus variable indicated the current tracking status Supporting SNMP Trap Data e sysName e cpqHoTrapFlags e cpqHeCorrMemLogStatus Supporting SNMP Trap Description Too many memory errors tr
12. SNMP Trap cpqDa TapeDriveCleaningRequired 3044 in CPQIDA MIB Symptom Tape Drive Cleaning Required trap The agent has detected a tape drive that needs to have a cleaning tape inserted and run This causes the tape drive heads to be cleaned Supporting SNMP Trap Data e sysName e cpqHoTrapFlags e cpqDaCntlrHwLocation e cpqDaTapeDrvCntlrindex Storage agents 69 e cpqDaTapeDrvBuslndex e cpqDaTapeDrvScsildIndex e cpqDaTapeDrvLunlndex e cpqDaTapeDrvyName e cpqDaTapeDrvFwRev e cpqDaTapeDrvSerialNumber Supporting SNMP Trap Description Cleaning is needed for the tape drive NT Event ID 1211 Hex 0x843504bb cpqstmsg dll Log Severity Warning 2 Event Title Drive Array Tape Drive Replace Cleaning Tape ay a The cleaning tape in the tape drive in 4 SCSI bus 5 SCSI target 6 needs to be replaced SNMP Trap cpqDa TapeDriveCleanTapeReplace 3045 in CPQIDA MIB Symptom Tape Drive Cleaning Tape Needs Replacing The agent has detected that an autoloader tape unit has a cleaning tape that has been fully used and therefore needs to be replaced with a new cleaning tape Supporting SNMP Trap Data e sysName e cpqHoTrapFlags e cpqDaCntlrHwLocation e cpqDaTapeDrvCntlrindex e cpqDaTapeDrvBuslndex e cpqDaTapeDrvScsildIndex e cpqDaTapeDrvLunlndex e cpqDaTapeDrvyName e cpqDaTapeDrvFwRev e cpqDaTapeDrvSerialNumber Supporting SNMP Trap Description Cleaning tape needs replacin
13. SNMP Trap cpqRackServerPowerOnFailedNotRedundant 22022 in CPQRACK MIB Symptom Server power on prevented to preserve redundancy There is not enough power to power on the server blade and maintain redundancy for the other blades in the enclosure User Action Check power connections or add power supplies Supporting SNMP Trap Data e sysName e cpqHoTrapFlags e cpqRackName e cpqRackUid e cpqRackServerBladeEnclosureName e cpqRackServerBladePosition e cpqRackServerBladeSparePartNumber e cpqRackCommonEnclosureSerialNum e cpqRackCommonEnclosureTrapSequenceNum Supporting SNMP Trap Description Server power on prevented to preserve redundancy in blade cpqRackServerBladePosition in enclosure cpqRackServerBladeEnclosureName in rack cpqRackName NT Event ID 1165 Hex 0xc435048d cpqsvmsg dll Log Severity Error 3 Event Title Not Enough Power To Power On Log Message Inadequate power to power on SNMP Trap cpqRackServerPowerOnFailedNotEnoughPower 22023 in CPQRACK MIB Symptom Inadequate power to power on There is not enough power to power on the server blade User Action Check power connections or add power supplies Supporting SNMP Trap Data e sysName e cpqHoTrapFlags e cpqRackName e cpqRackUid e cpqRackServerBladeEnclosureName e cpqRackServerBladePosition e cpqRackServerBladeSparePartNumber e cpqRackCommonEnclosureSerialNum e cpqRackCommonEnclosureTrapSequenceN
14. The server s processor fan has resumed normal operation Server agents 91 SNMP Trap cpqHe3ThermalCpuFanOk 6024 in CPQHLTH MIB Symptom The CPU fan status has been set to OK Any previously non operational processor fans have returned to normal operation Supporting SNMP Trap Data e sysName e cpqHoTrapFlags Supporting SNMP Trap Description CPU fan is now OK NT Event ID 1090 Hex 0x44350442 cpqsvmsg dll Log Severity Information 1 Log Message The server is operational again The server has previously been shut down by the Automatic Server Recovery ASR feature and has just become operational again SNMP Trap cpqHe3AsrConfirmation 6025 in CPQHLTH MIB Symptom The server is operational again The server has previously been shut down by the Automatic Server Recovery ASR feature and has just become operational again Supporting SNMP Trap Data e sysName e cpqHoTrapFlags Supporting SNMP Trap Description Server is operational again after ASR shutdown NT Event ID 1091 Hex 0x44350443 cpqsvmsg dll Log Severity Information 1 Log Message The server is operational again The server has previously been shut down due to a thermal anomaly and has just become operational again SNMP Trap cpqHe3ThermalConfirmation 6026 in CPQHLTH MIB Symptom The server is operational again The server has previously been shut down due to a thermal anomaly on the server and has just become operational
15. cpqDaCntlrFWRev e cpqDaAccelTotalMemory Supporting SNMP Trap Description Status is now cpqDaCntlrBoardStatus NT Event ID 1165 Hex 0x8435048d cpqstmsg dll Log Severity Warning 2 Event Title Drive Array Controller Active Log Message The Drive Array Controller in slot 4 has become the active controller SNMP Trap cpqDaCnilrActive 3016 in CPQIDA MIB Symptom Controller Active This trap indicates that the agent has detected that a backup array controller in a duplexed pair has switched over to the active role The variable cpqDaCnilrSlot indicates the active controller slot and cpqDaCntlrPartnerSlot indicates the backup User Action Check the partner controller for problems If this was the result of a user initiated switch over no action is required Supporting SNMP Trap Data e sysName e cpqHoTrapFlags e cpqDaCnilrSlot e cpqDaCntlrPartnerSlot Supporting SNMP Trap Description Controller in slot cpqDaCntlrSlot is now active NT Event ID 1173 Hex 0x84350495 cpqstmsg dil Log Severity Warning 2 Event Title Fibre Channel Tape Controller Status Change Log Message Fibre Channel tape controller with world wide name 4 has a new status of 5 SNMP Trap cpqgFcTapeCnilrStatusChange 16008 in CPQFCA MIB Symptom Fibre Channel Tape Controller Status Change This trap indicates that the agent has detected a change in the status of a Fiber Channel Tape Controller The variable
16. cpqSsBoxFltTolPwrSupplyStatus Supporting SNMP Trap Description Storage system power supply status changed to cpqSsBoxFltTolPwrSupplyStatus NT Event ID 1215 Hex 0x843504bf cpqstmsg dll Log Severity Warning 2 Event Title Fibre Channel Controller Status Change Log Message The Fibre Channel Controller in 4 has a new status of 5 SNMP Trap cpqFca3HostCntlrStatusChange 16028 in CPQFCA MIB Symptom Fibre Channel Host Controller Status Change This trap indicates that the agent has detected a change in the status of a Fibre Channel Host Controller The variable cpqFcaHostCnilrStatus indicates the current controller status User Action If the controller status is failed replace the controller Supporting SNMP Trap Data e sysName e cpqHoTrapFlags e cpqFcaHostCntlrHwLocation e cpqFcaHostCntlrindex e cpqFcaHostCntlrStatus e cpqFcaHostCntlrModel e cpqFcaHostCntlrSerialNumber e cpqFcaHostCntlrWorldWideName e cpqFcaHostCntlrWorldWidePortName Supporting SNMP Trap Description Host controller has a new status of cpqFcaHostCntlrStatus NT Event ID 1216 Hex 0x843504c0 cpqstmsg dll Log Severity Warning 2 Event Title Drive Array Physical Drive Status Change Log Message The physical drive in 4 5 with serial number 7 has a new status of 2 SNMP Trap cpqDa7PhyDrvStatusChange 3046 in CPQIDA MIB Storage agents 72 Symptom Physical Drive Status Change This
17. cpqhsmsg dll Log Severity Error 3 Log Message The cluster network 4 has failed SNMP Trap cpqClusterNetworkFailed 15008 in CPQCLUS MIB Foundation agents 12 Symptom This trap is sent any time the condition of a cluster network has failed User Action Make a note of the cluster network name and then check the network for the cause of the failure Supporting SNMP Trap Data e sysName e cpqHoTrapFlags e cpqClusterNetworkName Supporting SNMP Trap Description Cluster network cpqClusterNetworkName has failed NT Event ID 1171 Hex 0x84350493 cpghsmsg dll Log Severity Warning 2 Log Message The cluster service on 4 has become degraded SNMP Trap cpqClusterNodeDegraded 15003 in CPQCLUS MIB Symptom This trap is sent any time the condition of a node in the cluster becomes degraded User Action Make a note of the cluster node name and then check the node for the cause of the degraded condition Supporting SNMP Trap Data e sysName e cpqHoTrapFlags e cpqClusterNodeName Supporting SNMP Trap Description Cluster service on cpqClusterNodeName has become degraded NT Event ID 1172 Hex 0xc4350494 cpqhsmsg dll Log Severity Error 3 Log Message The cluster service on 4 has failed SNMP Trap cpqClusterNodeFailed 15004 in CPQCLUS MIB Symptom This trap is sent any time the condition of a node in the cluster has failed User Action Make a note of the cluster node
18. cpqldeldentIndex has become degraded NT Event ID 1122 Hex 0x44350462 cpqstmsg dil Log Severity Information 1 Event Title IDE Drive Status OK Log Message The IDE drive 4 has returned to a normal operating condition SNMP Trap cpqideDriveOk 14002 in CPQIDE MIB Symptom An IDE drive status has been set to OK User Action None Supporting SNMP Trap Data e sysName e cpqHoTrapFlags e cpqldeldentIndex Supporting SNMP Trap Description IDE drive cpqldeldentIndex has returned to normal operating condition Storage agents 41 NT Event ID 1145 Hex 0xc4350479 cpqstmsg dil Log Severity Error 3 Event Title External Array Logical Drive Status Change Log Message Logical drive number 5 on array 4 has a new status of 6 SNMP Trap cpgExtArrayLogDrvStatusChange 16022 in CPQFCA MIB Symptom External Array Logical Drive Status Change This trap indicates that the agent has detected a change in the status of an External Array logical drive The variable cpqFcalogDrvStatus indicates the current logical drive status User Action If the logical drive status is failed examine the array for failed drives that need replacement Supporting SNMP Trap Data e sysName e cpqHoTrapFlags e cpqSsChassisName e cpqSsChassisTime e cpqFcalogDrvBoxlndex e cpqFcalogDrvindex e cpqFcalogDrvStatus e cpqFcalogDrvOsName e cpqFcalogDrvFaultTol e cpqFcalogDrvSize Supporting SNMP T
19. e cpqHeFltTolPowerSupplySerialNumber e cpqHeFltTolPowerSupplyAutoRev e cpqHeFltTolPowerSupplyFirmwareRev e cpqHeFltTolPowerSupplySparePartNum e cpqSiServerSystemld Supporting SNMP Trap Description The Power Supply is Failed on Chassis cpqHeFltTolPowerSupplyChassis Bay cpqHeFltTolPowerSupplyBay Status cpqHeFltTolPowerSupplyStatus Model cpqHeFltTolPowerSupplyModel Serial Num cpqHeFltTolPowerSupplySerialNumber Firmware cpqHeFltTolPowerSupplyFirmwareRev NT Event ID 1126 Hex 0x84350466 cpqsvmsg dll Log Severity Warning 2 Log Message The Fault Tolerant Power Supply Sub system has lost redundancy Restore power or replace any failed or missing power supplies SNMP Trap cpqHe3FltTolPowerRedundancyLost 6032 in CPQHLTH MIB Symptom The Fault Tolerant Power Supplies have lost redundancy for the specified chassis Supporting SNMP Trap Data e sysName e cpqHoTrapFlags e cpqHeFltTolPowerSupplyChassis Supporting SNMP Trap Description The Power Supplies are no longer redundant on Chassis cpqHeFltTolPowerSupplyChassis NT Event ID 1127 Hex 0x44350467 cpqsvmsg dll Log Severity Information 1 Log Message Fault Tolerant Power Supply Inserted A hot plug fault tolerant power supply has been inserted into the system SNMP Trap cpqHe3FltTolPowerSupplylnserted 6033 in CPQHLTH MIB Symptom A Fault Tolerant Power Supply has been inserted into the specified chassis and bay loc
20. Change This trap indicates that the agent has detected a change in the status of an External Channel Array spare drive The variable cpqFcaSpareStatus indicates the current spare drive status The variable coqFcaSpareBusNumber indicates the SCSI bus number associated with this drive User Action If the spare drive status is failed replace the drive Supporting SNMP Trap Data e sysName e cpqHoTrapFlags e cpqSsChassisName e cpqSsChassisTime e cpqFcaSpareBusNumber e cpqFcaSpareBay e cpqFcaSpareStatus Supporting SNMP Trap Description Spare Status is now cpqFcaSpareStatus on bus cpqFcaSpareBusNumber NT Event ID 1148 Hex 0xc435047c cpqstmsg dll Log Severity Error 3 Event Title External Array Accelerator Status Change Log Message The array accelerator board attached to the external controller in I O slot 5 of array 4 has a new status of 6 SNMP Trap cpgFca2AccelStatusChange 16017 in CPQFCA MIB Symptom External Array Accelerator Board Status Change This trap indicates that the agent has detected a change in the status of an Array Accelerator Cache Board The current status is represented by the variable cpgFcaAccelStatus User Action If the accelerator board status is permDisabled 5 you may need to replace the accelerator board Supporting SNMP Trap Data e sysName e cpqHoTrapFlags Storage agents 43 e cpqSsChassisName e cpgSsChassisTime e cpqFcaAccelBox
21. Cluster service may not be running Try to restart the Cluster service Event identifier cpqhsmsg dll 3860 Hex 0x44350f14 Service Event Log Severity Information 1 Log Message Resource status is online Event identifier cpqhsmsg dll 3861 Hex 0x44350f15 Service Event Log Severity Information 1 Log Message Resource status is offline The resource has failed or was taken offline by a cluster administrator Event identifier coqhsmsg dll 3862 Hex 0x44350f16 Service Event Log Severity Information 1 Log Message Could not get the resource status The Cluster service may not be running Try to restart the Cluster service Event identifier coqhsmsg dll 3863 Hex 0x44350f17 Service Event Log Severity Information 1 Log Message Resource status is inherited Event identifier coqhsmsg dll 3864 Hex 0x44350f18 Service Event Log Severity Information 1 Log Message Resource status is initializing The Cluster service is starting Event identifier cpqhsmsg dll 3865 Hex 0x44350f19 Service Event Log Severity Information 1 Log Message Resource status is pending The Cluster service is starting or the resource is being put back online or being taken offline Event identifier cpqhsmsg dll 3866 Hex 0x44350f1a Service Event Log Severity Information 1 Foundation agents 23 Log Message Resource status is online pending The resource is being put back online Event identifier cpoqhsmsg d
22. Data e sysName e cpqHoTrapFlags Storage agents 47 e cpqTapeLibrarySerialNumber Supporting SNMP Trap Description Tape library cpqTapeLibrarySerialNumber is not operational NT Event ID 1157 Hex 0x84350485 cpqstmsg dll Log Severity Warning 2 Event Title SCSI Tape Library OK Log Message The SCSI tape library with SCSI target 6 connected to SCSI bus 5 of the controller in slot 4 has recovered from errors SNMP Trap cpqTape3LibraryOkay 5011 in CPQSCSI MIB Symptom Tape Library Okay The Insight Agent has detected that an autoloader unit has recovered from errors Supporting SNMP Trap Data e sysName e cpqHoTrapFlags e cpqTapeLibrarySerialNumber Supporting SNMP Trap Description Tape Library cpqTapeLibrarySerialNumber Recovered NT Event ID 1158 Hex 0x84350486 cpqstmsg dll Log Severity Warning 2 Event Title SCSI Tape Library Degraded Log Message The SCSI tape library with SCSI target 6 connected to SCSI bus 5 of the controller in slot 4 is in a degraded condition SNMP Trap cpqTape3LibraryDegraded 5012 in CPQSCSI MIB Symptom Tape Library Degraded The Insight Agent has detected that an autoloader unit is in a degraded condition e Supporting SNMP Trap Data e sysName e cpqHoTrapFlags e cpqTapeLibrarySerialNumber Supporting SNMP Trap Description Tape library cpqTapeLibrarySerialNumber is in a degraded condition NT Event
23. ID 1159 Hex 0x84350487 cpqstmsg dll Log Severity Warning 2 Event Title SCSI Tape Library Door Open Log Message The SCSI tape library with SCSI target 6 connected to SCSI bus 5 of the controller in slot 4 has a door open so the unit is not operational SNMP Trap cpqTape3LibraryDoorOpen 5013 in CPQSCSI MIB Symptom Tape Library Door Open The Insight Agent has detected that the door on an autoloader is open so the unit is not operational Supporting SNMP Trap Data e sysName Storage agents 48 e cpqHoTrapFlags e cpqTapeLibrarySerialNumber Supporting SNMP Trap Description Tape library cpqTapeLibrarySerialNumber door opened NT Event ID 1160 Hex 0x84350488 cpqstmsg dll Log Severity Warning 2 Event Title SCSI Tape Library Door Closed Log Message The SCSI tape library with SCSI target 6 connected to SCSI bus 5 of the controller in slot 4 has a closed door and is now operational SNMP Trap cpqTape3LibraryDoorClosed 5014 in CPQSCSI MIB Symptom Tape Library Door Closed The Insight Agent has detected that the door on an autoloader has closed Supporting SNMP Trap Data e sysName e cpqHoTrapFlags e cpq apelibrarySerialNumber Supporting SNMP Trap Description Tape library cpqTapeLibrarySerialNumber door closed NT Event ID 1161 Hex 0xc4350489 cpqstmsg dll Log Severity Error 3 Event Title SCSI CD Library Status Change Log Message The CD Library wit
24. Log Message The Foundation Agents service could not initialize agent 1 The data contains the error code Event identifier coqhsmsg dll 267 Hex 0x8435010b Service Event Log Severity Warning 2 Log Message The Foundation Agents service could not start agent 1 The data contains the error code Event identifier coqhsmsg dll 268 Hex 0x8435010c Service Event Log Severity Warning 2 Log Message The Foundation Agents service detected an invalid state for agent 1 The data contains the state Event identifier coqhsmsg dll 269 Hex 0x8435010d Service Event Log Severity Warning 2 Log Message The Foundation Agents service could not stop agent 1 The data contains the error code Event identifier coqhsmsg dll 270 Hex 0x8435010e Service Event Log Severity Warning 2 Log Message The Foundation Agents service could not terminate agent 1 The data contains the error code Event identifier coqhsmsg dll 271 Hex 0x8435010f Service Event Log Severity Warning 2 Log Message The Foundation Agents service could not unload the module 1 The data contains the error code Event identifier coqhsmsg dll 272 Hex 0x84350110 Service Event Log Severity Warning 2 Log Message The Foundation Agents service could not create the registry key 1 The data contains the error code Event identifier coqhsmsg dll 273 Hex 0x84350111 Service Event Log Sever
25. Log Severity Error 3 Log Message Redundancy has been reduced by the NIC in slot 1 port 2 Number of functional NICs in the team 3 SNMP Trap cpqNicRedundancyReduced 18004 in CPQNIC MIB Symptom This trap is sent any time a physical adapter in a logical adapter group changes to the Failed condition but at least one physical adapter remains in the OK condition This can be caused by loss of link due to a cable being removed from the adapter or the Hub or Switch Internal adapter Hub or Switch failures can also cause this condition User Action Check the cables to the adapter and the Hub or Switch If no cable problems are found the adapter Hub or Switch may need replacement Supporting SNMP Trap Data e sysName NIC agents 135 e cpqHoTrapFlags e cpqNiclfPhysAdapterSlot e cpqNiclfPhysAdapterPort e cpqNiclflogMapAdapterOKCount Supporting SNMP Trap Description Redundancy decreased by adapter in slot cpqNiclfPhysAdapterSlot port cpqNiclfPhysAdapterPort NT Event ID 1290 Hex 0x4435050A cpqnimsg dll Log Severity Information 1 Log Message Connectivity has been restored for the NIC in slot 1 port 2 SNMP Trap cpqNic3ConnectivityRestored 18011 in CPQNIC MIB Symptom This trap is sent any time connectivity is restored to a logical adapter This occurs when the physical adapter in a single adapter configuration returns to the OK condition or at least one physical adapter in a
26. Message 1 The data contains the error code Event identifier cpqhsmsg dll 2308 Hex 0x84350904 Service Event Log Severity Warning 2 Log Message The Threshold Agent could not read the registry value 1 The data contains the error code Event identifier cpqhsmsg dll 2309 Hex 0x84350905 Service Event Log Severity Warning 2 Log Message The Threshold Agent found an incorrect type for registry value 1 The data contains the type found Event identifier cpqhsmsg dll 2310 Hex 0x84350906 Service Event Log Severity Warning 2 Log Message The Threshold Agent could not create a necessary event The data contains the error code Event identifier cpqhsmsg dll 2311 Hex 0x84350907 Service Event Log Severity Warning 2 Log Message The Threshold Agent could not set an event The data contains the error code Event identifier coqhsmsg dll 2312 Hex 0x84350908 Service Event Log Severity Warning 2 Foundation agents 19 Log Message The Threshold Agent could not create its main thread of execution The data contains the error code Event identifier coqhsmsg dll 2313 Hex 0x84350909 Service Event Log Severity Warning 2 Log Message The Threshold Agent main thread did not terminate properly The data contains the error code Event identifier cpqhsmsg dll 2314 Hex 0x8435090a Service Event Log Severity Warning 2 Log Message The Threshold Agent got an unexpected e
27. Storage Agents may correct this problem Event identifier cpqstmsg dll 1803 Hex 0xc435070b Service Event Log Severity Error 3 Log Message Unable to load a required library This error can be caused by a corrupt or missing file Reinstalling the Storage Agents or running the Emergency Repair procedure may correct this error Event identifier cpqstmsg dll 1804 Hex 0x8435070c Service Event Log Severity Warning 2 Log Message The Storage SNMP Agent was unable to forward an SNMP trap to the Remote Insight Board trap due to processing error The data contains the error code Event identifier cpqstmsg dll 1806 Hex 0x8435070e Service Event Log Severity Warning 2 Log Message The Storage Agent service is not running The SNMP Agent has determined that the Storage Agent service is not running Stop the SNMP service and restart the Storage Agents service If the error persists reinstalling the Storage Agents may correct this error Event identifier cpqstmsg dll 1807 Hex 0x4435070f Service Event Log Severity Information 1 Log Message The Storage SNMP Agent has determined the Storage Agents service is running Event identifier cpqstmsg dll 1808 Hex 0x443507 10 Service Event Log Severity Information 1 Log Message The agent could not deliver trap 1 The agent was unable to use Asynchronous Management to deliver a trap This can be caused by a failure in the Remote Access Service or by a missing or i
28. Storage agents 50 cpqFcTapeCnitlrStatus indicates the current tape controller status The variable cpqFcTapeCntlhPWWN indicates the unique tape controller world wide name associated with this controller User Action If the tape controller status is offline access to the tape library and tapes has been lost Check the tape library and all Fibre connections for problems Supporting SNMP Trap Data e sysName e cpqHoTrapFlags e cpgFcTapeCntlhWWN e cpqFcTapeCntlrStatus Supporting SNMP Trap Description Status is now cpqFcTapeCnitlrStatus for tape controller cpqFcTapeCntlhWWN NT Event ID 1174 Hex 0x84350496 cpqstmsg dil Log Severity Warning 2 Event Title Fibre Channel Tape Library Status Change Log Message The Fibre Channel tape library on tape controller with world wide name 4 SCSI bus 5 SCSI target 6 has a new status of 7 SNMP Trap cpgFcTapeLibraryStatusChange 16009 in CPQFCA MIB Symptom Fibre Channel Tape Library Status Change This trap indicates that the agent has detected a change in the status of a Fiber Channel Tape library The variable cpqFcTapeLibraryStatus indicates the current tape library status The variable cpgqFcTapeLibraryScsiTarget indicates the SCSI ID of the tape library User Action If the tape library is failed or is offline check the tape library front panel and all fibre channel connections Supporting SNMP Trap Data e sysName e cpqHoTrapFlags e
29. Symptom The PagingFile Usage performance property is set to degraded Supporting SNMP Trap Data e sysName e cpqHoTrapFlags e cpqOsPagingFilelndex e cpqOsPagingFilelnstance e cpqOsPageFileUsagePercent Supporting SNMP Trap Description The PagingFile performance instance cpqOsPagingFilelnstance is degraded with PagingFile Usage of cpqOsPageFileUsagePercent percent NT Event ID 1178 Hex 0xc435049a cpqhsmsg dll Log Severity Error 3 Log Message The PagingFile Performance Instance 4 is failed with PagingFile Usage of 5 percent SNMP Trap cpqOsPageFileUsageFailed 19006 in CPQWINOS MIB Symptom The PagingFile Usage performance property is set to critical Supporting SNMP Trap Data e sysName e cpqHoTrapFlags e cpqOsPagingFilelndex e cpqOsPagingFilelnstance e cpqOsPageFileUsagePercent Foundation agents 15 Supporting SNMP Trap Description The PagingFile performance instance cpqOsPagingFilelnstance is critical with PagingFile Usage of cpqOsPageFileUsagePercent percent NT Event ID 1179 Hex 0x8435049b cpqhsmsg dll Log Severity Warning 2 Log Message The Logical Disk Performance Instance 4 is degraded with Disk Busy Time of 5 percent SNMP Trap cpqOsLogicalDiskBusyTimeDegraded 19007 in CPQWINOS MIB Symptom The LogicalDisk BusyTime performance property is set to degraded Supporting SNMP Trap Data e sysName e cpqHoTrapFlags e cpqOs
30. again Supporting SNMP Trap Data e sysName e cpqHoTrapFlags Supporting SNMP Trap Description Server is operational again after thermal shutdown NT Event ID 1092 Hex 0x84350444 cpqsvmsg dll Log Severity Warning 2 Log Message Post Errors were detected One or more Power On Self Test errors were detected during server startup SNMP Trap cpqHe3PostError 6027 in CPQHLTH MIB Symptom One or more POST errors occurred Power On Self Test POST errors occur during the server restart process Supporting SNMP Trap Data e sysName e cpqHoTrapFlags Server agents 92 Supporting SNMP Trap Description Errors occurred during server restart Event Identifiers 1103 1183 NT Event ID 1103 Hex 0x8435044f cpqsvmsg dll Log Severity Warning 2 Log Message The Fault Tolerant Power Sub system has been set to Degraded Check power connections and replace the power supply as needed SNMP Trap cpqHe3FltTolPwrSupplyDegraded 6028 in CPQHLTH MIB Symptom The fault tolerant power supply sub system condition has been set to degraded Supporting SNMP Trap Data e sysName e cpqHoTrapFlags Supporting SNMP Trap Description The server power supply status has become degraded NT Event ID 1108 Hex 0x84350454 cpqsvmsg dll Log Severity Warning 2 Log Message The Remote Insight Board has detected unauthorized login attempts More than 4 login attempts detected SNMP Trap cpqSm2Unaut
31. been inserted into the specitied chassis and slot User Action None Supporting SNMP Trap Data e sysName e cpqHoTrapFlags e cpqSiHotPlugSlotChassis e cpqSiHotPlugSlotIndex Supporting SNMP Trap Description Hot Plug Slot Board Inserted into Chassis cpqSiHotPlugSlotChassis Slot cpqSiHotPlugSlotIndex NT Event ID 1142 Hex 0xc4350476 cpqsvmsg dll Log Severity Error 3 Log Message Hot Plug PCI Board Failed A hot plug PCI adapter has failed to power up Insure the board and all cables are installed correctly SNMP Trap cpqSiHotPlugSlotPowerUpFailed 2010 in CPQSINFO MIB Symptom Hot Plug Slot Board Failed Power Up A Hot Plug Slot Board has failed to power up in the specified chassis and slot User Action Be sure the board and all cables are installed correctly and that the board type and revision are the same as the replaced board Supporting SNMP Trap Data e sysName e cpqHoTrapFlags e cpqSiHotPlugSlotChassis Server agents 103 e cpqSiHotPlugSlotIndex e cpqSiHotPlugSlotErrorStatus Supporting SNMP Trap Description Hot Plug Slot Board Failed in Chassis cpqSiHotPlugSlotChassis Slot cpqSiHotPlugSlotIndex Error cpqSiHotPlugSlotErrorStatus NT Event ID 1143 Hex 0x44350477 cpqsvmsg dll Log Severity Information 1 Log Message Rack Name Changed SNMP Trap cpqRackNameChanged 22001 in CPQRACK MIB Symptom The rack name has changed This trap indicates
32. condition Rebooting the server may correct this error Event identifier cpqstmsg dll 1284 Hex 0x84350504 Service Event Log Severity Warning 2 Log Message Could not write the registry subkey 1 This error can be caused by a corrupt registry or a low memory condition Rebooting the server may correct this error Event identifier cpqstmsg dll 1285 Hex 0x84350505 Service Event Log Severity Warning 2 Log Message Could not write the registry subkey 1 This error can be caused by a corrupt registry or a low memory condition Rebooting the server may correct this error Event identifier cpqstmsg dll 1294 Hex 0x8435050e Service Event Log Severity Warning 2 Log Message Unsupported storage system The ProLiant storage system 1 is unsupported by this version of the Storage Agents Upgrade the agents to the latest version Event Identifiers 1343 4613 Event identifier cpqstmsg dll 1343 Hex 0x8435053f Service Event Log Severity Warning 2 Log Message Duplicate SCSI port found in slot 1 The current system ROM may not support this SCSI controller You may need to update your system ROM Event identifier cpqstmsg dll 1344 Hex 0x84350540 Service Event Log Severity Warning 2 Log Message A version mismatch has been detected with the SCSI device monitor driver CPQSDM SYS The current driver version is 1 Cause You may not have rebooted after a Storage Agents upgrade Always reboot
33. cpqDaTapelibraryScsiTarget indicates the SCSI ID of the tape library User Action If the tape library is failed check the tape library front panel Supporting SNMP Trap Data e sysName e cpqHoTrapFlags e cpqDaCntlrHwLocation e cpqDaTapelibraryCntlrindex e cpqDaTapelLibraryScsiBus e cpqDaTapelLibraryScsiTarget e cpqDaTapelLibraryScsiLun e cpqDaTapeLibraryModel e cpqDaTapelLibraryFWRev e cpqDaTapelibrarySerialNumber e cpqDaTapelibraryStatus Supporting SNMP Trap Description Status is now cpqDaTapeLibraryStatus for the tape library NT Event ID 1208 Hex 0x843504b8 cpqstmsg dll Log Severity Warning 2 Event Title Drive Array Tape Library Door Status Change Log Message The tape library in 4 SCSI bus 5 SCSI target 6 has a new door status of 7 SNMP Trap cpqDa TapeLibraryDoorStatusChange 3042 in CPQIDA MIB Symptom Tape Library Door Status Change This trap indicates that the agent has detected a change in the door status of a tape library The variable cpqDaTapeLibraryDoorStatus indicates the current tape library door status The variable coqDaTapeLibraryScsiTarget indicates the SCSI ID of the tape library User Action If the tape library door is open close the tape library door Supporting SNMP Trap Data e sysName e cpqHoTrapFlags e cpqDaCntlrHwLocation e cpqDaTapelibraryCntlrindex e cpqDaTapelLibraryScsiBus e cpqDaTapelLibraryScsiTarget e cpqDaTapelLibraryScs
34. cpqNiclfPhysAdapterSlot port cpqNiclfPhysAdapterPort NT Event ID 1293 Hex 0xc435050D cpqnimsg dll Log Severity Error 3 Log Message Redundancy has been reduced by the NIC in slot 1 port 2 Number of functional NICs in the team 3 SNMP Trap cpqNic3RedundancyReduced 18014 in CPQNIC MIB NIC agents 137 Symptom This trap is sent any time a physical adapter in a logical adapter group changes to the Failed condition but at least one physical adapter remains in the OK condition This can be caused by loss of link due to a cable being removed from the adapter or the Hub or Switch Internal adapter Hub or Switch failures can also cause this condition User Action Check the cables to the adapter and the Hub or Switch If no cable problems are found the adapter Hub or Switch may need replacement Supporting SNMP Trap Data e sysName e cpqHoTrapFlags e cpqNiclfPhysAdapterSlot e cpqNiclfPhysAdapterPort e cpqSiServerSystemld e cpqNiclfPhysAdapterStatus e cpqSePciSlotBoardName e cpqNiclfPhysAdapterPartNumber e ipAdEntAddr e cpqNiclfLogMaplPV Address e cpqNiclflogMapAdapterOKCount Supporting SNMP Trap Description Redundancy decreased by adapter in slot cpqNiclfPhysAdapterSlot port cpqNiclfPhysAdapterPort NIC agents 138
35. cpqnimsg dll 300 Hex 0x8435012c Service Event Log Severity Warning 2 Log Message The WBEM query was cancelled by WMI The query was issued again Cause WMI service was probably restarted Event identifier cpqnimsg dll 1024 Hex 0x84350400 Service Event Log Severity Warning 2 Log Message The SNMP Insight Agent is unable to generate traps due to an error during initialization Cause Check to Be sure that the SNMP service is running Reinstalling the agents may fix this error Event identifier cpqnimsg dll 1025 Hex 0x84350401 Service Event Log Severity Warning 2 Log Message The NIC SNMP Management Agent s trap thread has encountered an error while waiting for event notification from event log Event identifier cpqnimsg dll 1027 Hex 0x84350403 Service Event Log Severity Warning 2 Log Message The SNMP Agent is older than other components The SNMP Agent is older than the other components of the Insight Agents Reinstall the entire Insight Agents package to correct this error Event identifier cpqnimsg dll 1028 Hex 0x84350404 Service Event Log Severity Warning 2 Log Message The 1 Agent is older than other components The 1 Agent is older than the other components of the Insight Agents Reinstall the entire Insight Agents package to correct this error Event identifier cpqnimsg dll 1029 Hex 0x84350405 Service Event Log Severity Warning 2 Log Message The NIC SNMP Management Ag
36. e cpqHoTrapFlags e cpqRackName e cpqRackUid e cpqRackCommonEnclosureName e cpqRackCommonEnclosureSerialNum e cpqRackCommonEnclosureTempLocation e cpqRackCommonEnclosureSparePartNumber e cpqRackCommonEnclosureTrapSequenceNum Supporting SNMP Trap Description The enclosure coqRackCommonEnclosureName temperature sensor in rack cpqRackName has been set to ok NT Event ID 1150 Hex 0xc435047e cpqsvmsg dll Log Severity Error 3 Event Title Rack Enclosure Fan Failed Log Message This trap indicates that an enclosure fan has failed and less than the minimum number of fans in the redundant fan group are operating This may result in overheating of the enclosure SNMP Trap cpgRackEnclosureFanFailed 22008 in CPQRACK MIB Symptom The enclosure fan status has been set to failed This trap indicates that an enclosure fan has failed and that no other fans in the redundant fan group are operating This may result in the enclosure overheating User Action Replace the fan as soon as possible Supporting SNMP Trap Data e sysName e cpqHoTrapFlags e cpqRackName Server agents 107 e cpqRackUid e cpqRackCommonEnclosureName e cpqRackCommonEnclosureSerialNum e cpqRackCommonEnclosureFanLocation e cpqRackCommonEnclosureFanSparePartNumber e cpqRackCommonEnclosureTrapSequenceNum Supporting SNMP Trap Description The enclosure cpqRackCommonEnclosureName fan in rack cpqRackName
37. event log of the system named 1 The data contains the error code Event identifier cpqsvmsg dll 772 Hex 0xc4350304 Service Event Log Severity Error 3 Log Message The Remote Alerter Agent detected a null handle on initialization The data contains the error code Event identifier cpqsvmsg dll 773 Hex 0xc4350305 Service Event Log Severity Error 3 Log Message The Remote Alerter Agent received an error on WaitForMultipleObjects call The data contains the error code Event identifier cpqsvmsg dll 774 Hex 0xc4350306 Service Event Log Severity Error 3 Log Message The Remote Alerter Agent received an error on ResetEvent call The data contains the error code Server agents 84 Event Identifiers 1024 1092 NT Event ID 1024 Hex 0xc4350400 cpqsvmsg dll Log Severity Error 3 Log Message A cache accelerator parity error indicates a cache module needs to be replaced SNMP Trap cpqHe3CacheAccelParityError 6046 in CPQHLTH MIB Symptom A cache accelerator parity error indicates that a cache module needs to be replaced The error information is reported in the variable cpqHeEventLogErrorDesc Supporting SNMP Trap Data e sysName e cpqHoTrapFlags Supporting SNMP Trap Description Cache Accelerator errors may require a replacement module NT Event ID 1025 Hex 0x84350401 cpqsvmsg dll Log Severity Warning 2 Log Message The Advanced Memory Protection subsystem has detected a memory
38. fault The Online Spare Memory has been activated Schedule server down time to replace the memory SNMP Trap cpqHeResilientMemOnlineSpareEngaged 6047 in CPQHLTH MIB Symptom Advanced Memory Protection Online Spare Engaged The Advanced Memory Protection subsystem has detected a memory fault The Online Spare Memory has been activated User Action Schedule server down time to replace the faulty memory Supporting SNMP Trap Data e sysName e cpqHoTrapFlags Supporting SNMP Trap Description The Advanced Memory Protection subsystem has engaged the online spare memory NT Event ID 1026 Hex 0x84350402 cpqsvmsg dll Log Severity Warning 2 Log Message The Advanced Memory Protection sub system has detected a memory fault The Mirrored Memory has been activated Schedule server down time to replace the memory SNMP Trap cpqHeResilientMemMirroredMemoryEngaged 6051 in CPQHLTH MIB Symptom Advanced Memory Protection Mirrored Memory Engaged The Advanced Memory Protection subsystem has detected a memory fault Mirrored Memory has been activated User Action Replace the faulty memory Supporting SNMP Trap Data e sysName e cpqHoTrapFlags Supporting SNMP Trap Description The Advanced Memory Protection subsystem has engaged the online spare memory Server agents 85 NT Event ID 1027 Hex 0x84350403 cpqsvmsg dll Log Severity Warning 2 Log Message The Advanced Memory Protection sub system
39. identifier coqhsmsg dll 3075 Hex 0x84350c03 Service Event Log Severity Warning 2 Log Message Unable to read 1 from the registry This error can be caused by a corrupt registry or a low memory condition Rebooting the server may correct this error Event identifier cpqhsmsg dll 3076 Hex 0x84350c04 Service Event Log Severity Warning 2 Log Message Unable to read 1 from the registry This error can be caused by a corrupt registry or a low memory condition Rebooting the server may correct this error Event identifier cpqhsmsg dll 3084 Hex 0xc4350c0c Service Event Log Severity Error 3 Log Message Unable to read configuration 1 from the registry This error can be caused by a corrupt registry a low memory condition or incomplete configuration Reconfigure the Management Agents using the control panel Rebooting the server may also correct this error Event identifier cpqhsmsg dll 3085 Hex 0x84350c0d Service Event Log Severity Warning 2 Log Message Unable to write 1 to the registry This error can be caused by a corrupt registry or a low memory condition Rebooting the server may correct this error Foundation agents 21 Event identifier cpqhsmsg dll 3086 Hex 0x84350c0e Service Event Log Severity Warning 2 Log Message Unable to load a required library This error can be caused by a corrupt or missing file Reinstalling the Management Agents or running the Emergency Repai
40. name and then check the node for the cause of the failure Supporting SNMP Trap Data e sysName e cpqHoTrapFlags e cpqClusterNodeName Supporting SNMP Trap Description Cluster service on cpqClusterNodeName has failed NT Event ID 1173 Hex 0x84350495 cpghsmsg dil Log Severity Warning 2 Log Message The Processor Performance Instance 4 is degraded with Processor Time of 5 percent SNMP Trap cpqOsCpuTimeDegraded 19001 in CPQWINOS MIB Foundation agents 13 Symptom The Processor Time performance property is set to degraded Supporting SNMP Trap Data e sysName e cpqHoTrapFlags e cpqOsCpulndex e cpqOsCpulnstance e cpqOsCpuTimePercent Supporting SNMP Trap Description The Processor performance Instance cpqOsCpulnstance is degraded with Processor Time of cpqOsCpuTimePercent percent NT Event ID 1174 Hex 0xc4350496 cpqhsmsg dll Log Severity Error 3 Log Message The Processor Performance Instance 4 is failed with Processor Time of 5 percent SNMP Trap cpqOsCpuTimeFailed 19002 in CPQWINOS MIB Symptom The Processor Time performance property is set to critical Supporting SNMP Trap Data e sysName e cpqHoTrapFlags e cpqOsCpulndex e cpqOsCpulnstance e cpqOsCpuTimePercent Supporting SNMP Trap Description The Processor performance Instance cpqOsCpulnstance is critical with Processor Time of cpqOsCpuTimePercent percent NT Event ID
41. started Event identifier cpqstmsg dll 401 Hex 0x44350191 Service Event Log Severity Information 1 log Message 1 Event identifier cpqstmsg dll 512 Hex 0x84350200 Service Event Log Severity Warning 2 Log Message Unable to allocate memory This indicates a low memory condition Rebooting the system will correct this error Event identifier cpqstmsg dll 513 Hex 0x84350201 Service Event Log Severity Warning 2 Log Message Could not read from the registry subkey This error can be caused by a corrupt registry or a low memory condition Rebooting the server may correct this error Event identifier cpqstmsg dll 514 Hex 0x84350202 Service Event Log Severity Warning 2 Log Message Could not write the registry subkey 1 This error can be caused by a corrupt registry or a low memory condition Rebooting the server may correct this error Event identifier cpqstmsg dll 515 Hex 0x84350203 Service Event Log Severity Warning 2 Log Message Could not read the registry subkey 1 This error can be caused by a corrupt registry or a low memory condition Rebooting the server may correct this error Event identifier cpqstmsg dll 516 Hex 0x84350204 Service Event Log Severity Warning 2 Log Message Could not read the registry subkey 1 This error can be caused by a corrupt registry or a low memory condition Rebooting the server may correct this error Event identifier cpq
42. that an agent or utility has changed the name of the rack Each of the server blades in each of the enclosure within the rack is updated to reflect the new rack name It may take several minutes for the rack name change to be propagated throughout the entire rack User Action None Supporting SNMP Trap Data e sysName e cpqHoTrapFlags e cpqRackName e cpqRackUid e cpqRackSerialNum e cpqRackTrapSequenceNum Supporting SNMP Trap Description The rack name has changed to cpqRackName NT Event ID 1144 Hex 0x44350478 cpqsvmsg dll Log Severity Information 1 Log Message Rack Enclosure Name Changed SNMP Trap cpqRackEnclosureNameChanged 22002 in CPQRACK MIB Symptom The enclosure name has changed This trap indicates that an agent or utility has changed the name of an enclosure within the rack Each of the components within the rack is updated to reflect the new enclosure name It may take several minutes for the enclosure name change to be propagated throughout the entire enclosure User Action None Supporting SNMP Trap Data e sysName e cpqHoTrapFlags e cpqRackName e cpqRackUid e cpqRackCommonEnclosureName e cpqRackCommonEnclosureSerialNum e cpqRackCommonEnclosureModel e cpqRackCommonEnclosureSparePartNumber e cpqRackCommonEnclosureTrapSequenceNum Server agents 104 Supporting SNMP Trap Description The enclosure name has changed to cpqRackCommonEnclosureNam
43. the current temperature status User Action If the temperature status is degraded or failed shut down the storage system as soon as possible Be sure that the storage system environment is being cooled properly and that no components are overheated Supporting SNMP Trap Data e sysName e cpqHoTrapFlags e cpqSsBoxCntlrHwLocation e cpqSsBoxCntlrindex e cpqSsBoxBuslndex e cpqSsBoxVendor Storage agents 74 e cpqSsBoxModel e cpgqSsBoxSerialNumber e cpqSsBoxTempStatus e cpqSsBoxLocationString Supporting SNMP Trap Description Storage System temperature status changed to cpqSsBoxTempStatus NT Event ID 1220 Hex 0x843504c4 cpqstmsg dll Log Severity Warning 2 Event Title Storage System Fault Tolerant Power Supply Status Change Log Message The fault tolerant power supply in the 6 7 storage system connected to 5 of the controller in 4 has a new status of 2 SNMP Trap cpgSs6PwrSupplyStatusChange 8031 in CPQSTSYS MIB Symptom Storage System Fault Tolerant Power Supply Status Change The agent has detected a change in the power supply status of a storage system The variable cpqSsBoxFltTolPwrSupplyStatus indicates the current power supply status User Action If the power supply status is degraded restore power or replace the failed power supply Supporting SNMP Trap Data e sysName e cpqHoTrapFlags e cpqSsBoxCntlrHwLocation e cpqSsBoxCntlrindex e cpqSsBox
44. the system is working properly Supporting SNMP Trap Data e sysName e cpqHoTrapFlags Supporting SNMP Trap Description Hood is removed from unit NT Event ID 1116 Hex 0x8435045c cpqsvmsg dll Log Severity Warning 2 Log Message The Remote Insight Board has detected that the mouse cable is disconnected SNMP Trap cpqSm2MouseCableDisconnected 9009 in CPQSM2 MIB Symptom Mouse Cable Disconnected The Remote Insight mouse cable has been disconnected Supporting SNMP Trap Data e sysName e cpqHoTrapFlags Server agents 95 Supporting SNMP Trap Description Remote Insight mouse cable disconnected NT Event ID 1117 Hex 0x8435045d cpqsvmsg dll Log Severity Warning 2 Log Message The Remote Insight Board has detected that the external power cable is disconnected SNMP Trap cpqSm2ExternalPowerCableDisconnected 9010 in CPQSM2 MIB Symptom External Power Cable Disconnected The Remote Insight external power cable has been disconnected Supporting SNMP Trap Data e sysName e cpqHoTrapFlags Supporting SNMP Trap Description Remote Insight external power cable disconnected NT Event ID 1118 Hex 0x4435045e cpqsvmsg dll Log Severity Information 1 Log Message The Fault Tolerant Power Supply Sub system has been returned to the OK state SNMP Trap cpqHe4FltTolPowerSupplyOk 6048 in CPQHLTH MIB Symptom The fault tolerant power supply condition has been set back to the OK stat
45. too may power enclosures The maximum number of power enclosures has been exceeded User Action Remove the extra power enclosure Supporting SNMP Trap Data e sysName e cpqHoTrapFlags e cpqRackName e cpqRackUid e cpqRackCommonEnclosureName e cpqRackCommonEnclosureSerialNum e cpqRackCommonEnclosureTrapSequenceNum Server agents 121 Supporting SNMP Trap Description Power subsystem has too may power enclosures cpqRackCommonEnclosureName in rack cpqRackName NT Event ID 1178 Hex 0x8435049a cpqsvmsg dll Log Severity Warning 2 Event Title Power Subsystem Configuration Error Log Message The power subsystem has been improperly configured SNMP Trap cpqRackPowerChassisConfigError 22036 in CPQRACK MIB Symptom Power subsystem improperly configured The power subsystem has been improperly configured User Action Check the cabling of the power enclosure Supporting SNMP Trap Data e sysName e cpqHoTrapFlags e cpqRackName e cpqRackUid e cpqRackCommonEnclosureName e cpqRackCommonEnclosureSerialNum e cpqRackCommonEnclosureSparePartNumber e cpqRackCommonEnclosureTrapSequenceNum Supporting SNMP Trap Description Power subsystem has been improperly configured in enclosure cpqRackCommonEnclosureName in rack cpqRackName NT Event ID 1179 Hex 0x8435049B cpqsvmsg dil Log Severity Warning 2 Log Message The Management Processor is in reset st
46. 021 in CPQHLTH MIB Symptom The system fan status has been set to degraded An optional system fan is not operating normally Supporting SNMP Trap Data e sysName e cpqHoTrapFlags Supporting SNMP Trap Description An optional fan is not operating normally NT Event ID 1087 Hex 0x4435043f cpqsvmsg dll Log Severity Information 1 Log Message A System Fan Condition has been set to OK The server s system fan has resumed normal operation SNMP Trap cpqHe3ThermalSystemFanOk 6022 in CPQHLTH MIB Symptom The system fan status has been set to OK Any previously non operational system fans have returned to normal operation Supporting SNMP Trap Data e sysName e cpqHoTrapFlags Supporting SNMP Trap Description System fan has returned to normal operation NT Event ID 1088 Hex 0xc4350440 cpqsvmsg dll Log Severity Error 3 Log Message A Processor Fan Condition has been set to failed The system will be shut down due to this condition SNMP Trap cpqHe3ThermalCpuFanFailed 6023 in CPQHLTH MIB Symptom The CPU fan status has been set to failed A processor fan is not operating normally The server is shut down Supporting SNMP Trap Data e sysName e cpqHoTrapFlags Supporting SNMP Trap Description CPU fan has failed Server will be shutdown NT Event ID 1089 Hex 0x44350441 cpqsvmsg dll Log Severity Information 1 Log Message A Processor Fan Condition has been set to OK
47. 0x84350484 cpqsvmsg dll Log Severity Warning 2 Event Title Rack Power Supply Degraded Log Message This trap indicates that a power supply has degraded SNMP Trap cpqRackPowerSupplyDegraded 22014 in CPQRACK MIB Symptom The power supply status has been set to degraded This trap indicates that a power supply has degraded User Action Replace the power supply as soon as possible Server agents 110 Supporting SNMP Trap Data e sysName e cpqHoTrapFlags e cpqRackName e cpqRackUid e cpqRackPowerSupplyEnclosureName e cpqRackPowerSupplySerialNum e cpqRackPowerSupplyPosition e cpqRackPowerSupplyFWRev e cpqRackPowerSupplySparePartNumber e cpgRackCommonEnclosureSerialNum e cpqRackCommonEnclosureTrapSequenceNum Supporting SNMP Trap Description The power supply cpqRackPowerSupplyPosition in enclosure cpqRackPowerSupplyEnclosureName in rack cpqRackName has been set to degraded NT Event ID 1157 Hex 0x44350485 cpqsvmsg dll Log Severity Information 1 Event Title Rack Power Supply OK Log Message This trap indicates that a power supply has returned to normal operation SNMP Trap cpqRackPowerSupplyOk 22015 in CPQRACK MIB Symptom The power supply status has been set to OK This trap indicates that a power supply has returned to normal operation User Action None Supporting SNMP Trap Data e sysName e cpqHoTrapFlags e cpqRackName e cpqRackUid e cpq
48. 1 SNMP Trap cpqHo2AppErrorTrap 11004 in CPQHOST MIB Symptom An application has generated an exception Specific error information is contained in the variable cpgHoSwPerfAppErrorDesc Supporting SNMP Trap Data e sysName e cpqHoTrapFlags e cpqHoSwPerfAppErrorDesc Supporting SNMP Trap Description cpqHoSwPerfAppErrorDesc NT Event ID 1162 Hex 0x8435048a cpqhsmsg dll Log Severity Warning 2 Log Message Rising Threshold Passed SNMP Trap cpqMeRisingAlarmExtended 10005 in CPQTHRSH MIB Symptom Rising Threshold passed An alarm entry has crossed its rising threshold The instances of those objects contained within the variable list are those of the alarm entry that generated this trap Supporting SNMP Trap Data e sysName e cpqHoTrapFlags Foundation agents 9 e cpqMeAlarmVariable e cpqMeAlarmSampleType e cpqMeAlarmValue e cpqMeAlarmRisingThreshold e cpqMeAlarmOwner e cp MeAlarmSeverity e cpqMeAlarmExtendedDescription Supporting SNMP Trap Description cpgMeAlarmOwner Variable cp qMeAlarmVariable has value cpqMeAlarmValue gt cpqMeAlarmRisingThreshold NT Event ID 1163 Hex 0x8435048b cpqhsmsg dll Log Severity Warning 2 Log Message Falling Threshold Passed SNMP Trap cpqMeFallingAlarmExtended 10006 in CPQTHRSH MIB Symptom Falling Threshold passed An alarm entry has crossed its falling threshold The instances of those objects conta
49. 1175 Hex 0x84350497 cpghsmsg dil Log Severity Warning 2 Log Message The Cache Performance Instance 4 is degraded with Cache Copy Read Hits of 5 percent SNMP Trap cpqOsCacheCopyReadHitsDegraded 19003 in CPQWINOS MIB Symptom The Cache CopyReadHits performance property is set to degraded Supporting SNMP Trap Data e sysName e cpqHoTrapFlags e cpqOsCachelndex e cpqOsCachelnstance e cpqOsCacheCopyReadHitsPercent Supporting SNMP Trap Description The Cache performance property is degraded with CopyReadHits of cpqOsCacheCopyReadHitsPercent percent NT Event ID 1176 Hex 0xc4350498 cpqhsmsg dll Log Severity Error 3 Foundation agents 14 Log Message The Cache Performance Instance 4 is failed with Cache Copy Read Hits of 5 percent SNMP Trap cpqOsCacheCopyReadHitsFailed 19004 in CPQWINOS MIB Symptom The Cache CopyReadHits performance property is set to critical Supporting SNMP Trap Data e sysName e cpqHoTrapFlags e cpqOsCachelndex e cpqOsCachelnstance e cpqOsCacheCopyReadHitsPercent Supporting SNMP Trap Description The Cache performance property is critical with CopyReadHits of cpqOsCacheCopyReadHitsPercent percent NT Event ID 1177 Hex 0x84350499 cpghsmsg dil Log Severity Warning 2 Log Message The PagingFile Performance Instance 4 is degraded with PagingFile Usage of 5 percent SNMP Trap cpqOsPageFileUsageDegraded 19005 in CPQWINOS MIB
50. 60c Service Event Log Severity Warning 2 Log Message The Rack And Enclosure MIB Agent received an unknown action code from the service The data contains the action code Server agents 127 Event identifier coqsvmsg dll 5645 Hex 0x8435 160d Service Event Log Severity Warning 2 Log Message The Rack And Enclosure MIB Agent could not get the system type The data contains the error code Event identifier cpqsvmsg dll 5682 Hex 0x8435 1632 Service Event Log Severity Warning 2 Log Message The Rack And Enclosure MIB Agent could not set the variable because it is unsupported The data contains the error code Event identifier cpqsvmsg dll 5683 Hex 0x8435 1633 Service Event Log Severity Warning 2 Log Message The Rack And Enclosure MIB Agent could not set the variable because the value is invalid or out of range The data contains the error code Event identifier cpqsvmsg dll 5684 Hex 0x8435 1634 Service Event Log Severity Warning 2 Log Message The Rack And Enclosure MIB Agent is not loaded Sets are not available The data contains the error code Server agents 128 NIC agents Event Identifiers 256 299 Event identifier cpqnimsg dll 256 Hex 0x84350100 Service Event Log Severity Warning 2 Log Message The NIC Management Agent detected an error The insertion string is 1 The data contain the error code Event identifier cpqnimsg dll 257 Hex 0x84350101 Service Event
51. 7 in CPQRACK MIB Symptom The power supply has been inserted User Action None Supporting SNMP Trap Data e sysName e cpqHoTrapFlags e cpqRackName e cpqRackUid e cpgRackPowerSupplyEnclosureName e cpqRackPowerSupplySerialNum e cpqRackPowerSupplyPosition e cpqRackPowerSupplyFWRev e cpqRackPowerSupplySparePartNumber e cpgRackCommonEnclosureSerialNum e cpqRackCommonEnclosureTrapSequenceNum Supporting SNMP Trap Description The power supply cpqRackPowerSupplyPosition in enclosure cpqRackPowerSupplyEnclosureName in rack cpqRackName has been inserted NT Event ID 1160 Hex 0x84350488 cpqsvmsg dll Log Severity Warning 2 Server agents 112 Event Title Rack Power Subsystem Not Redundant Log Message The rack power subsystem is no longer in a redundant state SNMP Trap cpqRackPowerSubsystemNotRedundant 22018 in CPQRACK MIB Symptom The rack power subsystem is no longer in a redundant state User Action Replace any failed power supplies as soon as possible to return the system to a redundant state Supporting SNMP Trap Data e sysName e cpqHoTrapFlags e cpqRackName e cpqRackUid e cpqRackPowerEnclosureName e cpqRackCommonEnclosureSerialNum e cpqRackCommonEnclosureTrapSequenceNum Supporting SNMP Trap Description The power subsystem in enclosure cpqRackPowerEnclosureName in rack cpqRackName is no longer redundant NT Event ID 1161 Hex 0x
52. 84350489 cpqsvmsg dll Log Severity Warning 2 Event Title Rack Power Subsystem Input Voltage Problem Log Message The rack power supply detected an input line voltage problem SNMP Trap cpqRackPowerSubsystemLineVoltageProblem 22019 in CPQRACK MIB Symptom The rack power supply detected an input line voltage problem User Action Check the power input for the power supply or replace any failed power supplies as soon as possible Supporting SNMP Trap Data e sysName e cpqHoTrapFlags e cpqRackName e cpqRackUid e cpqRackPowerSupplyEnclosureName e cpqRackPowerSupplyPosition e cpqRackPowerSupplyFWRev e cpqRackPowerSupplylnputLineStatus e cpqRackPowerSupplySparePartNumber e cpqRackCommonEnclosureSerialNum e cpqRackCommonEnclosureTrapSequenceNum Supporting SNMP Trap Description The rack power supply detected an input line voltage problem in power supply cpqRackPowerSupplyPosition enclosure cpqRackPowerSupplyEnclosureName rack cpqRackName NT Event ID 1162 Hex 0x8435048a cpqsvmsg dll Server agents 113 Log Severity Warning 2 Event Title Rack Power Subsystem Overload Log Message The rack power subsystem overload condition SNMP Trap cpqRackPowerSubsystemOverloadCondition 22020 in CPQRACK MIB Symptom The rack power subsystem overload condition User Action Replace any failed power supplies as soon as possible to return the system to a redundant state Supporting SNMP
53. 843504ab cpqstmsg dll Log Severity Warning 2 Event Title External Tape Drive Replace Cleaning Tape Log Message The cleaning tape in the tape drive at location 4 needs to be replaced SNMP Trap cpgExtTapeDriveCleanTapeReplace 16025 in CPQFCA MIB Symptom External Tape Drive Cleaning Tape Needs Replacing The agent has detected that an autoloader tape unit has a cleaning tape that has been fully used and therefore needs to be replaced with a new cleaning tape Supporting SNMP Trap Data e sysName e cpqHoTrapFlags e cpqFcTapeDriveCntlrindex e cpqFcTapeDriveScsiBus e cpqFcTapeDriveScsiTarget e cpqFcTapeDriveScsilun Storage agents 61 e cpqFcTapeDriveModel e cpqFcTapeDriveFWRev e cpqFcTapeDriveSerialNumber e cpqFcTapeDrivelocation Supporting SNMP Trap Description Cleaning tape needs replacing NT Event ID 1196 Hex 0x843504ac cpqstmsg dll Log Severity Warning 2 Event Title Storage System Recovery Server Option Status Change Log Message Storage system 4 has a new RSO status of 5 SNMP Trap cpqSsExRecoveryServerStatusChange 8025 in CPQSTSYS MIB Symptom Storage System Recovery Server Option Status Change The agent has detected a change in the recovery server option status of a storage system The variable cpoqSsChassisRsoStatus indicates the current status User Action If the RSO status is noSecondary 6 or linkDown 7 Be sure that the secondary server is operation
54. Buslndex e cpqSsBoxVendor e cpqSsBoxModel e cpqSsBoxSerialNumber e cpqSsBoxFltTolPwrSupplyStatus e cpqSsBoxlocationString Supporting SNMP Trap Description Storage System power supply status changed to cpqSsBoxFltTolPwrSupplyStatus NT Event ID 1221 Hex 0x843504c5 cpqstmsg dll Log Severity Warning 2 Event Title SAS SATA Physical Drive Status Change Log Message The physical drive in 4 5 with serial number 6 has a new status of 7 SNMP Trap cpgSasPhyDrvStatusChange 5022 in CPQSCSI MIB Symptom Physical Drive Status Change The Storage Agent has detected a change in the status of a SAS or SATA physical drive The current physical drive status is indicated in the cpqSasPhyDrvStatus variable Supporting SNMP Trap Data e sysName e cpqHoTrapFlags Storage agents 75 e cpgSasHbaHwLocation e cpqSasPhyDrvlocationString e cpgSasPhyDrvHbalndex e cpqSasPhyDrvindex e cpqSasPhyDrvStatus e cpqSasPhyDryType e cpqSasPhyDrvModel e cpqSasPhyDryFWRev e cpqSasPhyDrvSerialNumber e cpgqSasPhyDrvSasAddress Supporting SNMP Trap Description Status is now cpqSasPhyDrvStatus NT Event ID 1222 Hex 0x843504c6 cpqstmsg dll Log Severity Warning 2 Event Title SAS SATA Logical Drive Status Change Log Message Logical drive number 5 on the HBA in 4 has a new status of 6 SNMP Trap cpgSasLogDrvStatusChange 5023 in CPQSCSI MIB Symptom Lo
55. Change Log Message The Fibre Channel tape drive on tape controller with world wide name 4 SCSI bus 5 SCSI target 6 has a new status of 7 SNMP Trap cpqFcTapeDriveStatusChange 16011 in CPQFCA MIB Symptom Fibre Channel Tape Drive Status Change This trap indicates that the agent has detected a change in the status of a Fiber Channel Tape Drive The variable coqFcTapeDriveStatus indicates the current tape status The variable cpqFcTapeDriveScsiTarget indicates the SCSI ID of the tape drive User Action If the tape is failed or is offline check the tape and all fibre channel connections Supporting SNMP Trap Data e sysName e cpqHoTrapFlags e cpgFcTapeCntlhWWN e cpqFcTapeDriveScsiBus e cpqFcTapeDriveScsiTarget e cpqFcTapeDriveScsilun e cpqFclapeDriveStatus Supporting SNMP Trap Description Status is now cpqFcTapeDriveStatus for a tape drive Event ID 1177 Hex 0x84350499 cpqstmsg dll Log Severity Warning 2 Event Title Fibre Channel Tape Drive Cleaning Required Log Message The Fibre Channel tape drive on tape controller with world wide name 4 SCSI bus 5 SCSI target 6 requires cleaning SNMP Trap cpgFcTapeDriveCleaningRequired 16012 in CPQFCA MIB Symptom Fibre Channel Tape Drive Cleaning Required trap The agent has detected a tape drive that needs to have a cleaning tape inserted and run This causes the tape drive heads to be cleaned Storage agents 52 Supporti
56. He3FitTolPowerRedundancyRestored 6054 in CPQHLTH MIB Symptom The Fault Tolerant Power Supplies have returned to a redundant state for the specified chassis Supporting SNMP Trap Data e sysName e cpqHoTrapFlags e cpqHeFltTolPowerSupplyChassis Supporting SNMP Trap Description The Power Supplies are now redundant on Chassis cpqHeFltTolPowerSupplyChassis Server agents 86 NT Event ID 1030 Hex 0x44350406 cpqsvmsg dll Log Severity Information 1 Log Message The Fan Sub system has returned to a redundant state SNMP Trap cpqHe3FltTolFanRedundancyRestored 6055 in CPQHLTH MIB Symptom The Fault Tolerant Fans have returned to a redundant state for the specified chassis Supporting SNMP Trap Data e sysName e cpqHoTrapFlags e cpqHeFltTolFanChassis Supporting SNMP Trap Description The Fans are now redundant on Chassis cpqHeFltTolFanChassis NT Event ID 1035 Hex 0x8435040BL cpqsvmsg dll Log Severity Warning 2 Log Message Correctable or Uncorrectable memory error detected The memory module should be replaced SNMP Trap cpqHe5CorrMemReplaceMemModule 6064 in CPQHLTH MIB Symptom Corrected Memory Errors Detected The errors have been corrected but the memory module should be replaced Value O for CPU means memory is not processor based Supporting SNMP Trap Data e sysName e cpqHoTrapFlags e cpqHeResMem2BoardNum e cpq HeResMem2CpuNum e cpqHeResMem2RiserNu
57. HeFltTolFanChassis cpqHeFltTolFanlndex Supporting SNMP Trap Description The Fan Inserted on Chassis cpqHeFltTolFanChassis Fan cpqHeFltTolFanIndex NT Event ID 1133 Hex 0x8435046d cpqsvmsg dll Log Severity Warning 2 Log Message Fan Removed A hot plug fan has been removed from the system SNMP Trap cpqHe3FltTolFanRemoved 6039 in CPQHLTH MIB Symptom A Fault Tolerant Fan has been removed from the specified chassis and fan location Supporting SNMP Trap Data e sysName e cpqHoTrapFlags e cpqHeFltTolFanChassis cpqHeFltTolFanlndex Supporting SNMP Trap Description The Fan Removed on Chassis cpqHeFltTolFanChassis Fan cpqHeFltTolFanIndex NT Event ID 1134 Hex 0xc435046e cpqsvmsg dll Log Severity Error 3 Log Message A Temperature Sensor Condition has been set to failed The system will be shut down due to this overheat condition SNMP Trap cpqHe3TemperatureFailed 6040 in CPQHLTH MIB Symptom The temperature status has been set to failed in the specified chassis and location The system is shut down due to this condition Supporting SNMP Trap Data e sysName Server agents 100 e cpqHoTrapFlags e cpqHeTemperatureChassis e cpqHeTemperatureLocale Supporting SNMP Trap Description Temperature Exceeded on Chassis cpqHeTemperatureChassis Location cpqHeTemperatureLocale NT Event ID 1135 Hex 0x8435046f cpqsvmsg dll Log Severity Warning 2 Lo
58. Hex 0x443507 10 Service Event Log Severity Information 1 Log Message The agent could not deliver trap 1 The agent was unable to use Asynchronous Management to deliver a trap This can be caused by a failure in the Remote Access Service or by a missing or invalid configuration Use the Management Agent control panel to verity the Asynchronous Management configuration settings Use the Network control panel to verify the Remote Access configuration If this error persists reinstalling the Server Agents or the Remote Access Service may correct this error For more information see the Asynchronous Management documentation Event identifier coqsvmsg dll 3328 Hex 0x84350d00 Service Event Log Severity Warning 2 Log Message Unable to allocate memory This indicates a low memory condition Rebooting the system may correct this error Event identifier coqsvmsg dll 3329 Hex 0x84350d01 Service Event Log Severity Warning 2 Log Message Could not read from the registry sub key This error can be caused by a corrupt registry or a low memory condition Rebooting the server may correct this error Event identifier coqsvmsg dll 3330 Hex 0x84350d02 Service Event Log Severity Warning 2 Log Message Could not write the registry sub key 1 This error can be caused by a corrupt registry or a low memory condition Rebooting the server may correct this error Event identifier cpqsvmsg dll 3331 Hex 0x84350d03 Servic
59. Microsoft Windows Event ID and SNMP Traps Reference Guide For use with SmartStart version 8 25 en 2 Part number 347870 009 Ninth edition June 2009 Legal notices Copyright 2003 2009 Hewlett Packard Development Company L P The information contained herein is subject to change without notice The only warranties for HP products and services are set forth in the express warranty statements accompanying such products and services Nothing herein should be construed as constituting an additional warranty HP shall not be liable for technical or editorial errors or omissions contained herein Confidential computer software Valid license from HP required for possession use or copying Consistent with FAR 12 211 and 12 212 Commercial Computer Software Computer Software Documentation and Technical Data for Commercial Items are licensed to the U S Government under vendor s standard commercial license Microsoft Windows Windows NT and Windows Server are U S registered trademarks of Microsoft Corporation Contents EEEE CERERE A Py AN Par ere eee Ne PCr E T E A A ne cere Fem een A EA PEN MOET Eee Ta ee tr 4 Windows II event log format ia0 4 esayaesonsssecaetionss insnstengeuiteaasodntantedeceeeahete nasbeeqen tin cand saesteieustnasaatanedordauith 4 Agent descriptions vcs seesstaricassteveaneniansdeteneod aiid solbennehi e ae E er saan caudate wales Gls OR eE Sin 4 Where to go for additional help a5 sasexicanasanieeeua
60. P website http www hp com For HP technical support e In North America o Call 1 800 HP INVENT 1 800 474 6836 This service is available 24 hours a day 7 days a week For continuous quality improvement calls may be recorded or monitored o If you have purchased a Care Pack service upgrade call 1 800 633 3600 For more information about Care Packs see the HP website http www hp com e Outside North America call the nearest HP Technical Support Phone Center For telephone numbers for worldwide Technical Support Centers see the HP website http www hp com Introduction 5 Foundation agents Event Identifiers 256 774 Event identifier cpqhsmsg dll 256 Hex 0x84350100 Service Event Log Severity Warning 2 Log Message The Foundation Agents service detected an error The insertion string is 1 The data contains the error code Event identifier cpqhsmsg dll 257 Hex 0x84350101 Service Event Log Severity Warning 2 Log Message The Foundation Agents service could not allocate memory The data contains the error code Event identifier coqhsmsg dll 258 Hex 0x84350102 Service Event Log Severity Warning 2 Log Message The Foundation Agents service could not register with the Service Control Manager The data contains the error code Event identifier cpqhsmsg dll 259 Hex 0x84350103 Service Event Log Severity Warning 2 Log Message The Foundation Agents service could not set th
61. RackPowerSupplyEnclosureName e cpqRackPowerSupplySerialNum e cpqRackPowerSupplyPosition e cpqRackPowerSupplyFWRev e cpqRackPowerSupplySparePartNumber e cpqRackCommonEnclosureSerialNum e cpqRackCommonEnclosureTrapSequenceNum Supporting SNMP Trap Description The power supply cpqRackPowerSupplyPosition in enclosure cpqRackPowerSupplyEnclosureName in rack cpqRackName has been set to ok NT Event ID 1158 Hex 0x84350486 cpqsvmsg dll Log Severity Warning 2 Event Title Rack Power Supply Removed Log Message The power supply has been removed Server agents 111 SNMP Trap cpqRackPowerSupplyRemoved 22016 in CPQRACK MIB Symptom The power supply has been removed User Action None Supporting SNMP Trap Data e sysName e cpqHoTrapFlags e cpqRackName e cpqRackUid e cpqRackPowerSupplyEnclosureName e cpqRackPowerSupplySerialNum e cpqRackPowerSupplyPosition e cpqRackPowerSupplyFWRev e cpqRackPowerSupplySparePartNumber e cpgRackCommonEnclosureSerialNum e cpqRackCommonEnclosureTrapSequenceNum Supporting SNMP Trap Description The power supply cpqRackPowerSupplyPosition in enclosure cpqRackPowerSupplyEnclosureName in rack cpqRackName has been removed NT Event ID 1159 Hex 0x44350487 cpqsvmsg dll Log Severity Information 1 Event Title Rack Power Supply Inserted Log Message The power supply has been inserted SNMP Trap cpqRackPowerSupplylnserted 2201
62. RackServerBladePosition e cpqRackServerBladeSparePartNumber e cpqRackCommonEnclosureSerialNum cpqRackCommonEnclosureTrapSequenceNum Supporting SNMP Trap Description Server blade cpqRackServerBladeName removed from position cpqRackServerBladePosition in enclosure cpqRackServerBladeEnclosureName in rack cpqRackName NT Event ID 1171 Hex 0x44350493 cpqsvmsg dll Log Severity Information 1 Event Title Server Blade Inserted Log Message The server blade has been inserted from the enclosure SNMP Trap cpqRackServerBladelnserted 22029 in CPQRACK MIB Symptom Server blade inserted The server blade has been inserted into the enclosure User Action None Supporting SNMP Trap Data e sysName e cpqHoTrapFlags e cpqRackName e cpqRackUid e cpqRackServerBladeEnclosureName e cpqRackServerBladeName Server agents 118 e cpqRackServerBladePosition e cpgRackServerBladeS parePartNumber e cpgRackCommonEnclosureSerialNum e cpqRackCommonEnclosureTrapSequenceNum Supporting SNMP Trap Description Server blade cpqRackServerBladeName inserted into position cpqRackServerBladePosition in enclosure cpqRackServerBladeEnclosureName in rack cpqRackName NT Event ID 1172 Hex 0x84350494 cpqsvmsg dll Log Severity Warning 2 Event Title Rack Power Subsystem Not Load Balanced Log Message The power subsystem is out of balance for this power enclosure SNMP Trap cpqRa
63. ScsiPhyDrvModel e cpqScsiPhyDrvFWRev e cpqScsiPhyDrvSerialNum cpqScsiPhyDrvOsName Supporting SNMP Trap Description Status is now cpqScsiPhyDrvStatus NT Event ID 1075 Hex 0x84350433 cpqstmsg dll Log Severity Warning 2 Event Title Storage System Fan Status Change Log Message The 6 7 storage system connected to SCSI bus 5 of the controller in slot 4 has a new status of 2 SNMP Trap cpqSs3FanStatusChange 8008 in CPQSTSYS MIB Symptom Storage System fan status change The agent has detected a change in the Fan Status of a storage system The variable cpqSsBoxFanStatus indicates the current fan status User Action If the fan status is degraded or failed replace any failed fans Supporting SNMP Trap Data e sysName e cpqHoTrapFlags e cpqSsBoxFanStatus Supporting SNMP Trap Description Storage System fan status changed to cpqSsBoxFanStatus NT Event ID 1076 Hex 0xc4350434 cpqstmsg dll Log Severity Error 3 Event Title Storage System Temperature Failure Log Message The 6 7 storage system connected to SCSI bus 5 of the controller in slot 4 has a failed temperature status Shut down the storage system as soon as possible SNMP Trap cpqSs3TempFailed 8009 in CPQSTSYS MIB Symptom Storage System temperature failure The agent has detected that a temperature status has been set to failed The storage system is shut down User Action Shut down the storage system as soon
64. TempOk 8011 in CPQSTSYS MIB Symptom Storage System temperature OK The temperature status has been set to OK The storage system s temperature has returned to normal operating range It may be reactivated by the administrator User Action None Supporting SNMP Trap Data e sysName e cpqHoTrapFlags e cpqSsBoxTempStatus Supporting SNMP Trap Description Storage System temperature ok Event identifier cpqstmsg dll 1098 Hex 0x4435044a Service Event Log Severity Information 1 Log Message Drive Array Physical Drive Monitoring is not enabled The physical drive in slot 4 port 5 bay 6 with serial number 7 does not have drive threshold monitoring enabled Event Identifiers 1101 1199 NT Event ID 1101 Hex 0x8435044d cpqstmsg dil Storage agents 38 Log Severity Warning 2 Event Title Storage System Side Panel Removed Log Message The side panel has been removed on the 6 7 storage system connected to SCSI bus 5 of the controller in slot 4 SNMP Trap cpqSs3SidePanelRemoved 8013 in CPQSTSYS MIB Symptom Storage System side panel is removed The side panel status has been set to removed The storage system s side panel is not in a properly installed state This situation may result in improper cooling of the drives in the storage system due to air flow changes caused by the missing side panel User Action Replace the storage system side panel Supporting SNMP Trap Data e sysNam
65. Trap cpqHe4FltTolPowerSupplyDegraded 6049 in CPQHLTH MIB Symptom The fault tolerant power supply condition has been set to degraded for the specified chassis and bay location Supporting SNMP Trap Data e sysName e cpqHoTrapFlags e cpqHeFltTolPowerSupplyChassis e cpqHeFltTolPowerSupplyBay e cpqHeFltTolPowerSupplyStatus e cpqHeFltTolPowerSupplyModel e cpqHeFltTolPowerSupplySerialNumber e cpqHeFltTolPowerSupplyAutoRev e cpqHeFltTolPowerSupplyFirmwareRev e cpqHeFltTolPowerSupplySparePartNum e cpqSiServerSystemld Supporting SNMP Trap Description The Power Supply is Degraded on Chassis cpqHeFltTolPowerSupplyChassis Bay cpqHeFltTolPowerSupplyBay Status cpqHeFltTolPowerSupplyStatus Model cpqHeFltTolPowerSupplyModel Serial Num cpqHeFltTolPowerSupplySerialNumber Firmware cpqHeFltTolPowerSupplyFirmwareRev NT Event ID 1125 Hex 0xc4350465 cpqsvmsg dll Log Severity Error 3 Log Message The Fault Tolerant Power Supply Sub system is in a failed state Restore power or replace the failed power supply SNMP Trap cpqHe4FltTolPowerSupplyFailed 6050 in CPQHLTH MIB Symptom The fault tolerant power supply condition has been set to failed for the specified chassis and bay location Supporting SNMP Trap Data e sysName e cpqHoTrapFlags e cpqHeFltTolPowerSupplyChassis e cpqHeFltTolPowerSupplyBay e cpqHeFltTolPowerSupplyStatus e cpqHeFltTolPowerSupplyModel Server agents 97
66. Trap Data e sysName e cpqHoTrapFlags e cpgRackName e cpqRackUid e cpqRackPowerEnclosureName e cpqRackCommonEnclosureSparePartNumber e cpqRackCommonEnclosureSerialNum e cpqRackCommonEnclosureTrapSequenceNum Supporting SNMP Trap Description The power subsystem in enclosure cpqRackPowerEnclosureName in rack cpqRackName is in an overload condition NT Event ID 1163 Hex 0xc435048b cpqsvmsg dll Log Severity Error 3 Event Title Server Power Shedding Shutdown Log Message Server shutdown due to power shedding SNMP Trap cpqRackPowerShedAutoShutdown 22021 in CPQRACK MIB Symptom Server shutdown due to power shedding The server blade was shut down due to a lack of power User Action Check power connections or add power supplies Supporting SNMP Trap Data e sysName e cpqHoTrapFlags e cpqRackName e cpqRackUid e cpqRackServerBladeEnclosureName e cpqRackServerBladePosition e cpqRackServerBladeSparePartNumber e cpqRackCommonEnclosureSerialNum e cpqRackCommonEnclosureTrapSequenceNum Supporting SNMP Trap Description The server shutdown due to lack of power blade cpqRackServerBladePosition in enclosure cpqRackServerBladeEnclosureName in rack cpqRackName NT Event ID 1164 Hex 0xc435048c cpqsvmsg dll Server agents 114 Log Severity Error 3 Event Title Server Power On Prevented Log Message Server power on prevented to preserve redundancy
67. acking now disabled NT Event ID 1082 Hex 0xc435043a cpqsvmsg dll Log Severity Error 3 Log Message A Thermal Temperature Condition has been set to failed The system will be shut down due to this thermal condition SNMP Trap cpqHe3ThermalTempFailed 6017 in CPQHLTH MIB Symptom The temperature status has been set to failed The system is shut down due to this thermal condition Supporting SNMP Trap Data e sysName Server agents 89 e cpqHoTrapFlags Supporting SNMP Trap Description System will be shut down due to this thermal condition NT Event ID 1083 Hex 0x8435043b cpqsvmsg dll Log Severity Warning 2 Log Message The Thermal Temperature Condition has been set to degraded The system may be shut down due to this thermal condition depending on the state of the thermal degraded action value 4 SNMP Trap cpqHe3ThermallempDegraded 6018 in CPQHLTH MIB Symptom The temperature status has been set to degraded The server s temperature is outside of the normal operating range The server is shut down if the cpqHeThermalDegradedAction variable is set to shutdown 3 Supporting SNMP Trap Data e sysName e cpqHoTrapFlags e cpqHeThermalDegradedAction Supporting SNMP Trap Description Temperature out of range Shutdown may occur NT Event ID 1084 Hex 0x4435043c cpqsvmsg dll Log Severity Information 1 Log Message The Thermal Temperature Condition has been set to OK The se
68. al and that all cables are connected properly If the RSO status is secondaryRunningAuto 8 or secondaryRunningUser 9 examine the primary server for failed components Supporting SNMP Trap Data e sysName e cpqHoTrapFlags e cpqSsChassisName e cpqSsChassisTime e cpqSsChassisRsoStatus e cpqSsChassisIndex Supporting SNMP Trap Description Storage system recovery server option status changed to cpqSsChassisRsoStatus NT Event ID 1197 Hex 0x843504ad cpqstmsg dll Log Severity Warning 2 Event Title External Tape Library Status Change Log Message The tape library at location 4 has a new status of 7 SNMP Trap cpgExtTapeLibraryStatusChange 16026 in CPQFCA MIB Symptom External Tape Library Status Change This trap indicates that the agent has detected a change in the status of an External Tape library The variable cpqFcTapeLibraryStatus indicates the current tape library status User Action If the tape library is failed or is offline check the tape library front panel and all connections Supporting SNMP Trap Data e sysName e cpqHoTrapFlags e cpqFcTapeLibraryCntlrindex e cpqFcTapelLibraryScsiBus Storage agents 62 e cpqFcTapeLibraryScsiTarget e cpgFcTapelibraryScsiLun e cpqFcTapeLibraryModel e cpqFcTapeLibraryFWRev e cpqFcTapeLibrarySerialNumber e cpgqFcTapeLibraryLocation e cpqFcTapeLibraryStatus Supporting SNMP Trap Description St
69. anagement procesessor again or re flash the management processor firmware Supporting SNMP Trap Data e sysName e cpqHoTrapFlags Supporting SNMP Trap Description The Management processor failed reset NT Event ID 1182 Hex 0x4435049EL Log Severity Informational Log Message USB storage device 5 attached The data contains the error code SNMP Trap 1008 in CPQSTDEQ MIB Symptom The USB key is attached to the server User Action None required Supporting SNMP Trap Data e sysName e cpqHoTrapFlags e cpqSeUSBDeviceType cpq SeUSBDeviceName Supporting SNMP Trap Description This trap is sent when a USB storage device has been attached Symbolic Name CPQ_STD_USB_DEV_ATTACHED NT Event ID 1183 Hex 0x4435049FL Log Severity Informational Log Message USB storage device 5 removed The data contains the error code SNMP TRAP 1009 in CPQSTDEQ MIB Symptom The USB key has been removed from the server User Action None required Supporting SNMP Trap Data Server agents 123 e sysName e cpqHoTrapFlags e cpqSeUSBDeviceType e cpq SeUSBDeviceName Supporting SNMP Trap Description This trap is sent when a attached USB storage device is removed Symbolic Name CPQ_STD_USB_DEV_REMOVED Event Identifiers 1539 3352 Event identifier cpqsvmsg dll 1539 Hex 0xc4350603 Service Event Log Severity Error 3 Log Message Unable to write to the registry This error can be caused
70. apePhyDrvCondition Supporting SNMP Trap Description Status is now cpqlapePhyDrvCondition NT Event ID 1120 Hex 0x84350460 cpqstmsg dll Log Severity Warning 2 Event Title SCSI Tape Drive Cleaning Tape Needs Replacing Log Message The tape drive with SCSI target 6 connected to SCSI bus 5 of the controller in slot 4 needs the cleaning tape replaced SNMP Trap cpqlape3PhyDrvCleanTapeReplace 5009 in CPQSCSI MIB Storage agents 40 Symptom Tape Drive Cleaning Tape Needs Replacing The Insight Agent has detected that an autoloader tape unit has a cleaning tape that has been fully used and therefore needs to be replaced with a new cleaning tape Supporting SNMP Trap Data e sysName e cpqHoTrapFlags e cpq apePhyDrvCondition Supporting SNMP Trap Description Status is now cpqlapePhyDrvCondition NT Event ID 1121 Hex 0x84350461 cpqstmsg dil Log Severity Warning 2 Event Title IDE Drive Status Degraded Log Message The IDE drive 4 has a degraded status and should be scheduled for replacement SNMP Trap cpqildeDriveDegraded 14001 in CPQIDE MIB Symptom An IDE drive status has been set to degraded User Action The drive should be scheduled for replacement For detailed information on a component replacement see the appropriate Maintenance and Service Guide Supporting SNMP Trap Data e sysName e cpqHoTrapFlags e cpqldeldentIndex Supporting SNMP Trap Description IDE drive
71. ard or cartridge has been inserted into the system SNMP Trap cpqHe5ResMemBoardInserted 6066 in CPQHLTH MIB Symptom Memory board or cartridge or riser inserted An Advanced Memory Protection sub system board cartridge or riser has been installed Value O for CPU means memory is not processor based User Action None SNMP Trap Data e sysName e cpqHoTrapFlags e cpqHeResMem2BoardSlotNum e cpqHeResMem2BoardCpuNum e cpqHeResMem2BoardRiserNum Supporting SNMP Trap Description Memory Board or Cartridge Inserted into Slot cpqHeResMem2BoardSlotNum Cpu cpqHeResMem2BoardCpuNum Riser cpqHeResMem2BoardRiserNum NT Event ID 1038 Hex 0xC435040EL cpqsvmsg dll Log Severity Error 3 Log Message A memory board or cartridge bus error has been detected in the memory subsystem SNMP Trap cpqgHe5ResMemBoardBusError 6067 in CPQHLTH MIB Symptom Memory board cartridge or riser bus error detected An Advanced Memory Protection sub system board cartridge or riser bus error has been detected Value O for CPU means memory is not processor based User Action Replace the indicated board or cartridge or Riser SNMP Trap Data e sysName e cpqHoTrapFlags e cpqHeResMem2BoardSlotNum e cpqHeResMem2BoardCpuNum Server agents 88 e cpqHeResMem2BoardRiserNum Supporting SNMP Trap Description Memory Board or Cartridge Inserted into Slot cpqHeResMem2BoardSlotNum Cpu cpqdeResMem2BoardCpuNum
72. as possible Insure that the storage system environment is being cooled properly and that no components are overheated Supporting SNMP Trap Data e sysName e cpqHoTrapFlags e cpqSsBoxTempStatus Storage agents 37 Supporting SNMP Trap Description Storage System will be shut down NT Event ID 1077 Hex 0x84350435 cpqstmsg dll Log Severity Warning 2 Event Title Storage System Temperature Degraded Log Message The 6 7 storage system connected to SCSI bus 5 of the controller in slot 4 system has a temperature outside the normal operating range SNMP Trap cpqSs3TempDegraded 8010 in CPQSTSYS MIB Symptom Storage System temperature degraded The agent has detected a temperature status that has been set to degraded The storage system s temperature is outside of the normal operating range User Action Shut down the storage system as soon as possible Be sure that the storage system environment is being cooled properly and that no components are overheated Supporting SNMP Trap Data e sysName e cpqHoTrapFlags e cpqSsBoxTempStatus Supporting SNMP Trap Description Temp is outside of normal range NT Event ID 1078 Hex 0x44350436 cpqstmsg dll Log Severity Information 1 Event Title Storage System Temperature OK Log Message The temperature in the 6 7 storage system connected to SCSI bus 5 of the controller in slot 4 has returned to the normal operating range SNMP Trap cpqSs3
73. ate The data contains the error code SNMP Trap ceqdeManagementProclnReset 6061 in CPQHLTH MIB Symptom The Management processor is currently in reset The management processor is currently in the process of being reset because of a firmware update or some other event User action None Supporting SNMP Trap Data e sysName e cpqHoTrapFlags Supporting SNMP Trap Description The Management processor is in the process of being reset NT Event ID 1180 Hex 0x0435049c cpqsvmsg dll Log Severity Informational 1 Log Message The Management Processor has successfully reset and is now available again The data contains the error code SNMP Trap cpgHeManagementProcReady 6062 in CPQHLTH MIB Symptom The Management processor is ready The management processor has successfully reset and is now available again Server agents 122 User action None Supporting SNMP Trap Data e sysName e cpqHoTrapFlags Supporting SNMP Trap Description The Management processor is ready after a successfull reset NT Event ID 1181 Hex 0x8435049D cpqsvmsg dil Log Severity Warning 3 Log Message The Management Processor has not reset successfully and is not operational The data contains the error code SNMP Trap cpqgHeManagementProcFailedReset 6063 in CPQHLTH MIB Symptom The Management processor failed reset The management processor was not successfully reset and is not operational User action Reset the m
74. ation Supporting SNMP Trap Data e sysName e cpqHoTrapFlags e cpqHeFltTolPowerSupplyChassis e cpqHeFltTolPowerSupplyBay Supporting SNMP Trap Description The Power Supply Inserted on Chassis cpqHeFltTolPowerSupplyChassis Bay cpqHeFltTolPowerSupplyBay NT Event ID 1128 Hex 0x84350468 cpqsvmsg dll Log Severity Warning 2 Log Message Fault Tolerant Power Supply Removed A hot plug fault tolerant power supply has been removed from the system SNMP Trap cpqHe3FltTolPowerSupplyRemoved 6034 in CPQHLTH MIB Server agents 98 Symptom A Fault Tolerant Power Supply has been removed from the specified chassis and bay location Supporting SNMP Trap Data e sysName e cpqHoTrapFlags e cpqHeFltTolPowerSupplyChassis cpqHeFltTolPowerSupplyBay Supporting SNMP Trap Description The Power Supply Removed on Chassis cpqHeFltTolPowerSupplyChassis Bay cpqHeFltTolPowerSupplyBay NT Event ID 1129 Hex 0x84350469 cpqsvmsg dll Log Severity Warning 2 Log Message The Fan Sub system is in a degraded state Replace the fan SNMP Trap cpqHe3FltTolFanDegraded 6035 in CPQHLTH MIB Symptom The Fault Tolerant Fan condition has been set to degraded for the specified chassis and fan Supporting SNMP Trap Data e sysName e cpqHoTrapFlags e cpqHeFltTolFanChassis e cpqHeFltTolFanlndex Supporting SNMP Trap Description The Fan Degraded on Chassis cpqHeFltTolFanChassis Fan cpqHeFltT
75. ature status is degraded or failed shut down the storage system as soon as possible Be sure that the storage system environment is being cooled properly and that no components are overheated Supporting SNMP Trap Data e sysName e cpqHoTrapFlags e cpqSsBoxCntlrHwLocation e cpqSsBoxCntlrindex e cpqSsBoxBuslndex e cpqSsBoxVendor e cpqSsBoxModel e cpqSsBoxSerialNumber e cpqSsBoxTempStatus Supporting SNMP Trap Description Storage System temperature status changed to cpqSsBoxTempStatus NT Event ID 1214 Hex 0x843504be cpqstmsg dll Log Severity Warning 2 Event Title Storage System Fault Tolerant Power Supply Status Change Log Message The fault tolerant power supply in the 6 7 storage system connected to SCSI bus 5 of the controller in 4 has a new status of 2 SNMP Trap cpqSs5PwrSupplyStatusChange 8028 in CPQSTSYS MIB Symptom Storage System Fault Tolerant Power Supply Status Change The agent has detected a change in the power supply status of a storage system The variable cpqSsBoxFltTolPwrSupplyStatus indicates the current power supply status Storage agents 71 User Action If the power supply status is degraded restore power or replace the failed power supply Supporting SNMP Trap Data e sysName e cpqHoTrapFlags e cpqSsBoxCntlrHwLocation e cpqSsBoxCntlrindex e cpqSsBoxBuslndex e cpqSsBoxVendor e cpqSsBoxModel e cpqSsBoxSerialNumber e
76. atus is now cpqFcTapeLibraryStatus for the tape library NT Event ID 1198 Hex 0x843504ae cpqstmsg dll Log Severity Warning 2 Event Title External Tape Library Door Status Change Log Message The tape library at location 4 has a new door status of 7 SNMP Trap cpgExtTapeLibraryDoorStatusChange 16027 in CPQFCA MIB Symptom External Tape Library Door Status Change This trap indicates that the agent has detected a change in the door status of an External Tape library The variable cpgFcTapeLibraryDoorStatus indicates the current tape library door status User Action If the tape library door is open close the tape library door Supporting SNMP Trap Data e sysName e cpqHoTrapFlags e cpqFcTapeLibraryCntlrindex e cpgFcTapeLibraryScsiBus e cpgFcTapeLibraryScsiTarget e cpqFcTapeLibraryScsiLun e cpqFcTapeLibraryModel e cpqFcTapeLibraryFWRev e cpqFcTapeLibrarySerialNumber e cpqFcTapeLibraryLocation e cpqFcTapeLibraryDoorStatus Supporting SNMP Trap Description The door is cpqFcTapeLibraryDoorStatus for tape library NT Event ID 1199 Hex 0x843504af cpqstmsg dll Log Severity Warning 2 Event Title Drive Array Controller Status Change Log Message The Drive Array Controller in 7 has a new status of 5 SNMP Trap cpqDa6 CnilrStatusChange 3033 in CPQIDA MIB Symptom Controller Status Change This trap indicates that the agent has detected a change in the st
77. atus of a drive array controller The variable coqDaCntlrBoardStatus indicates the current controller status Storage agents 63 User Action If the board status is generalFailure 3 you may need to replace the controller If the board status is cableProblem 4 check the cable connections between the controller and the storage system Supporting SNMP Trap Data e sysName e cpqHoTrapFlags e cpqDaCntlrHwLocation e cpqDaCntlrindex e cpqDaCntlrBoardStatus e cpqDaCntlrModel e cpqDaCntlrSerialNumber e cpqDaCntlrFWRev e cpqDaAccelTotalMemory Supporting SNMP Trap Description Status is now cpqDaCntlrBoardStatus Event Identifiers 1200 1294 NT Event ID 1200 Hex 0x843504b0 cpqstmsg dll Log Severity Warning 2 Event Title Drive Array Logical Drive Status Change Log Message Logical drive number 5 on the array controller in 4 has a new status of 2 SNMP Trap cpqDa LogDrvStatusChange 3034 in CPQIDA MIB Symptom Logical Drive Status Change This trap indicates that the agent has detected a change in the status of a drive array logical drive The variable cpqDaLogDrvStatus indicates the current logical drive status Supporting SNMP Trap Data e sysName e cpqHoTrapFlags e cpqDaCntlrHwLocation e cpqDalogDrvCntlrindex e cpqDalogDrvindex e cpqDalogDrvStatus Supporting SNMP Trap Description Status is now cpqDalogDrvStatus NT Event ID 1201 Hex 0x843504b1 cpqstmsg dil L
78. be caused by a corrupt or missing file Reinstalling the Insight Agents or running the Emergency Repair procedure may correct this error Event identifier cpqnimsg dll 1036 Hex 0x8435040c Service Event Log Severity Warning 2 Log Message The NIC SNMP Management Agent was unable to forward an SNMP trap to the Compaq Remote Insight Board trap due to processing error The data contains the error code Event identifier cpqnimsg dll 1037 Hex 0x8435040d Service Event Log Severity Warning 2 Log Message The NIC SNMP Management Agent was unable to get last modification time for key 1 Event identifier cpqnimsg dll 1038 Hex 0x8435040e Service Event Log Severity Warning 2 Log Message The Management Agent service is not running The SNMP Management Agent has determined that the Management Agent service is not running Stop the SNMP service and restart the Management Agents service If the error persists reinstalling the Management Agents may correct this error Event identifier cpqnimsg dll 1039 Hex 0x4435040f Service Event Log Severity Information 1 NIC agents 134 Log Message The NIC SNMP Management Agent has determined the Insight Agent Management service is running Event identifier cpqnimsg dll 1040 Hex 0x44350410 Service Event Log Severity Information 1 Log Message The agent could not deliver trap 1 The agent was unable to use Asynchronous Management to deliver a trap This can be ca
79. by a corrupt registry or a low memory condition Rebooting the server may correct this error Event identifier coqsvmsg dll 1540 Hex 0xc4350604 Service Event Log Severity Error 3 Log Message Unable to read from the registry This error can be caused by a corrupt registry or a low memory condition Rebooting the server may correct this error Event identifier cpqsvmsg dll 1543 Hex 0xc4350607 Service Event Log Severity Error 3 Log Message Unable to load a required driver This error can be caused by a corrupt or missing file Reinstalling the Server Agents the software support drivers or running the Emergency Repair procedure may correct this error Event identifier cpqsvmsg dll 1544 Hex 0x84350608 Service Event Log Severity Warning 2 Log Message Unable to read from the registry This error can be caused by a corrupt registry or a low memory condition Rebooting the server may correct this error Event identifier cpqsvmsg dll 1574 Hex 0xc4350626 Service Event Log Severity Error 3 Log Message Could not write the registry sub key 1 This error can be caused by a corrupt registry or a low memory condition Rebooting the server may correct this error Event identifier cpqsvmsg dll 1792 Hex 0x84350700 Service Event Log Severity Warning 2 Log Message The Server SNMP Agent is unable to generate traps due to an error during initialization Event identifier cpqsvmsg dll 1795 Hex 0
80. cale NT Event ID 1137 Hex 0x84350471 cpqsvmsg dll Log Severity Warning 2 Log Message The DC DC power converter is in a degraded state Replace the power converter SNMP Trap cpqHe3PowerConverterDegraded 6043 in CPQHLTH MIB Server agents 101 Symptom The DC DC Power Converter condition has been set to degraded for the specified chassis slot and socket Supporting SNMP Trap Data e sysName e cpqHoTrapFlags e cpqHePwrConvChassis e cpqHePwrConvSlot e cpqHePwrConvSocket Supporting SNMP Trap Description The Power Converter Degraded on Chassis cpqHePwrConvChassis Slot cpqHePwrConvSlot Socket cpqHePwrConvSockel NT Event ID 1138 Hex 0xc4350472 cpqsvmsg dll Log Severity Error 3 Log Message The DC DC power converter is in a failed state Replace the power converter SNMP Trap cpqHe3PowerConverterFailed 6044 in CPQHLTH MIB Symptom The DC DC Power Converter condition has been set to failed for the specified chassis slot and socket Supporting SNMP Trap Data e sysName e cpqHoTrapFlags e cpqHePwrConvChassis e cpqHePwrConvSlot e cpqHePwrConvSocket Supporting SNMP Trap Description The Power Converter Failed on Chassis cpqHePwrConvChassis Slot cpqHePwrConvSlot Socket cpqHePwrConvSocket NT Event ID 1139 Hex 0x84350473 cpqsvmsg dll Log Severity Warning 2 Log Message The DC DC power converter is in a failed state Replace Syst
81. change in the status of an External Tape Drive The variable cpqFcTapeDriveStatus indicates the current tape status User Action If the tape is failed or is offline check the tape and all connections Supporting SNMP Trap Data e sysName e cpqHoTrapFlags e cpqFcTapeDriveCntlrindex e cpqFcTapeDriveScsiBus e cpqFcTapeDriveScsiTarget e cpqFcTapeDriveScsilun Storage agents 60 e cpqFcTapeDriveModel e cpqFcTapeDriveFWRev e cpqFcTapeDriveSerialNumber e cpqFcTapeDrivelocation e cpqFclapeDriveStatus Supporting SNMP Trap Description Status is now cpqFcTapeDriveStatus for a tape drive NT Event ID 1194 Hex 0x843504aa cpqstmsg dll Log Severity Warning 2 Event Title External Tape Drive Cleaning Required Log Message The tape drive at location 4 requires cleaning SNMP Trap cpgExtTapeDriveCleaningRequired 16024 in CPQFCA MIB Symptom External Tape Drive Cleaning Required trap The agent has detected a tape drive that needs to have a cleaning tape inserted and run This causes the tape drive heads to be cleaned Supporting SNMP Trap Data e sysName e cpqHoTrapFlags e cpqFcTapeDriveCntlrindex e cpqFcTapeDriveScsiBus e cpqFcTapeDriveScsiTarget e cpqFcTapeDriveScsilun e cpqFcTapeDriveModel e cpqFcTapeDriveFWRev e cpqFcTapeDriveSerialNumber e cpqFcTapeDrivelocation Supporting SNMP Trap Description Cleaning is needed for tape drive NT Event ID 1195 Hex 0x
82. ckPowerChassisNotLoadBalanced 22030 in CPQRACK MIB Symptom Power subsystem not load balanced The power subsystem is out of balance for this power enclosure User Action Check the power enclosure and power supplies Replace any failed or degraded power supplies Add additional power supplies if needed Supporting SNMP Trap Data e sysName e cpqHoTrapFlags e cpqRackName e cpqRackUid e cpqRackCommonEnclosureName e cpqRackCommonEnclosureSerialNum e cpqRackCommonEnclosureSparePartNumber e cpqRackCommonEnclosureTrapSequenceNum Supporting SNMP Trap Description Power subsystem not load balanced in enclosure cpqRackCommonEnclosureName in rack cpqRackName NT Event ID 1173 Hex 0x84350495 cpqsvmsg dll Log Severity Warning 2 Event Title Power Subsystem DC Power Problem Log Message There is a power subsystem DC power problem for this enclosure SNMP Trap cpqRackPowerChassisDcPowerProblem 22031 in CPQRACK MIB Symptom Power subsystem DC power problem There is a power subsystem DC power problem for this power enclosure User Action Check the power enclosure and power supplies Replace any failed or degraded power supplies Supporting SNMP Trap Data e sysName e cpqHoTrapFlags e cpqRackName Server agents 119 e cpqRackUid e cpqRackCommonEnclosureName e cpqRackCommonEnclosureSerialNum e cpqRackCommonEnclosureSparePartNumber cpqRackCommonEnclosureTrapSequenceNum
83. d to normal operation User Action None Supporting SNMP Trap Data e sysName Server agents 108 e cpqHoTrapFlags e cpqRackName e cpqRackUid e cpqRackCommonEnclosureName e cpqRackCommonEnclosureSerialNum e cpqRackCommonEnclosureFanLocation e cpqRackCommonEnclosureFanSparePartNumber cpqRackCommonEnclosureTrapSequenceNum Supporting SNMP Trap Description The enclosure cpqRackCommonEnclosureName fan in rack cpqRackName has been set to ok NT Event ID 1153 Hex 0x84350481 cpqsvmsg dll Log Severity Warning 2 Event Title Rack Enclosure Fan Removed Log Message The enclosure fan has been removed SNMP Trap cpqRackEnclosureFfanRemoved 22011 in CPQRACK MIB Symptom The enclosure fan has been removed User Action None Supporting SNMP Trap Data e sysName e cpqHoTrapFlags e cpqRackName e cpqRackUid e cpqRackCommonEnclosureName e cpqRackCommonEnclosureSerialNum e cpqRackCommonEnclosureFanLocation e cpqRackCommonEnclosureFanSparePartNumber e cpqRackCommonEnclosureTrapSequenceNum Supporting SNMP Trap Description The enclosure cpqRackCommonEnclosureName fan in rack cpqRackName has been removed NT Event ID 1154 Hex 0x44350482 cpqsvmsg dll Log Severity Information 1 Event Title Rack Enclosure Fan Inserted Log Message The enclosure fan has been inserted SNMP Trap cpqgRackEnclosureFanInserted 22012 in CPQRACK MIB Symptom Th
84. dIndex e cpqTapeLibraryLunIndex e cpqTapeLibraryName Storage agents 59 e cpqTapeLibraryFwRev e cpqTapeLibrarySerialNumber e cpqTapeLibraryState Supporting SNMP Trap Description Status is now cpqTapeLibraryState NT Event ID 1192 Hex 0x843504a8 cpqstmsg dll Log Severity Warning 2 Event Title SCSI Tape Drive Status Change Log Message The tape drive with SCSI target 6 connected to SCSI bus 5 of the controller in slot 4 has a new status of 2 SNMP Trap cpqlape5PhyDrvStatusChange 5019 in CPQSCSI MIB Symptom Tape Drive Status Change The Storage Agent has detected a change in the status of a tape drive The current physical drive status is indicated in the cpqTapePhyDrvStatus variable Supporting SNMP Trap Data e sysName e cpqHoTrapFlags e cpq apePhyDrvCntlrindex e cpqTapePhyDrvBusIndex e cpq apePhyDrvScsildIndex e cpq apePhyDrvLunlndex e cpq apePhyDrvyName e cpq apePhyDryFwRev e cpq apePhyDrvSerialNumber e cpq apePhyDrvStatus Supporting SNMP Trap Description Status is now cpqTapePhyDrvStatus NT Event ID 1193 Hex 0x843504a9 cpqstmsg dll Log Severity Warning 2 Event Title External Tape Drive Status Change Log Message The tape drive at location 4 has a new status of 7 SNMP Trap cpgExtTapeDriveStatusChange 16023 in CPQFCA MIB Symptom External Tape Drive Status Change This trap indicates that the agent has detected a
85. del e cpqDaAccelCntlrindex e cpqDaAccelSerialNumber e cpqDaAccelTotalMemory Supporting SNMP Trap Description Accelerator lost battery power Data Loss possible NT Event ID 1206 Hex 0x843504b6 cpqstmsg dll Log Severity Warning 2 Event Title Drive Array Accelerator Battery Failed Log Message The array accelerator board attached to the array controller in 4 is reporting a battery failure SNMP Trap cpqDa AccelBatteryFailed 3040 in CPQIDA MIB Symptom Accelerator Board Battery Failed This trap indicates that the agent has detected a battery failure associated with the array accelerator cache board User Action Replace the Accelerator Cache Board Supporting SNMP Trap Data e sysName e cpqHoTrapFlags e cpqDaCntlrHwLocation e cpqDaCntlrModel e cpqDaAccelCntlrindex e cpqDaAccelSerialNumber e cpqDaAccelTotalMemory Supporting SNMP Trap Description Battery status is failed Storage agents 67 NT Event ID 1207 Hex 0x843504b7 cpqstmsg dll Log Severity Warning 2 Event Title Drive Array Tape Library Status Change Log Message The tape library in 4 SCSI bus 5 SCSI target 6 has a new status of 7 SNMP Trap cpqDa TapeLibraryStatusChange 3041 in CPQIDA MIB Symptom Tape Library Status Change This trap indicates that the agent has detected a change in the status of a tape library The variable cpqDaTapeLibraryStatus indicates the current tape library status The variable
86. e cpqDaPhyDrvBay e cpqDaPhyDrvModel e cpqDaPhyDrvFWRev e cpqDaPhyDrvSerialNum Supporting SNMP Trap Description Factory threshold passed for a physical drive NT Event ID 1062 Hex 0xc4350426 cpqstmsg dll Log Severity Error 3 Event Title Drive Array Logical Drive Status Change Log Message Logical drive number 5 on the array controller in slot 4 has a new status of 2 SNMP Trap cpqDa3LogDrvStatusChange 3008 in CPQIDA MIB Symptom Logical Drive Status Change This trap indicates that the agent has detected a change in the status of a drive array logical drive The variable cpqDalogDrvStatus indicates the current logical drive status Supporting SNMP Trap Data e sysName e cpqHoTrapFlags e cpqDalogDrvStatus Supporting SNMP Trap Description Status is now cpqDalogDrvStatus NT Event ID 1063 Hex 0xc4350427 cpqstmsg dll Log Severity Error 3 Event Title Drive Array Spare Drive Status Change Log Message The spare drive in slot 4 port 5 bay 6 has a new status of 2 SNMP Trap cpqDa4SpareStatusChange 3017 in CPQIDA MIB Symptom Spare Drive Status Change This trap indicates that the agent has detected a change in the status of a drive array spare drive The variable coqDaSpareStatus indicates the current spare drive status User Action If the spare drive status is failed replace the drive Supporting SNMP Trap Data e sysName e cpqHoTrapFlags e cpqDaSpareStat
87. e cpqFcaHostCntlrWorldWideName Supporting SNMP Trap Description Host controller in slot cpqFcaHostCntlrSlot has a new status of cpqFcaHostCnilrStatus NT Event ID 1186 Hex 0x843504a2 cpqstmsg dll Log Severity Warning 2 Event Title IDE ATA Disk Status Change Log Message The ATA disk drive with model 6 and serial number 7 has a new status of 2 Storage agents 56 SNMP Trap cpqideAtaDiskStatusChange 14004 in CPQIDE MIB Symptom ATA Disk Status Change This trap indicates that the agent has detected a change in the status of an ATA disk drive The variable cpqldeAtaDiskStatus indicates the current disk drive status User Action If the physical drive status is smartError 3 or failed 4 replace the drive Supporting SNMP Trap Data e sysName e cpqHoTrapFlags e cpqldeAtaDiskControllerIndex e cpqldeAtaDisklndex e cpqldeAtaDiskModel e cpqldeAtaDiskFwRev e cpqldeAtaDiskSerialNumber e cpqldeAtaDiskStatus e cpqldeAtaDiskChannel e cpqldeAtaDiskNumber Supporting SNMP Trap Description Status is now cpqldeAtaDiskStatus for the ATA disk NT Event ID 1187 Hex 0x843504a3 cpqstmsg dll Log Severity Warning 2 Event Title ATA RAID Logical Drive Status Change Log Message ATA RAID logical drive number 6 on the 5 in slot 4 has a new status of 2 SNMP Trap cpqidelogicalDriveStatusChange 14005 in CPQIDE MIB Symptom IDE Logical Drive Status Change This trap indicat
88. e cpqNiclfPhysAdapterSlot e cpqNiclfPhysAdapterPort e cpqSiServerSystemld e cpqNiclfPhysAdapterStatus e cpqSePciSlotBoardName e cpqNiclfPhysAdapterPartNumber e ipAdEntAddr e cpqNiclflLogMaplPV Address Supporting SNMP Trap Description Connectivity lost for adapter in slot cpqNiclfPhysAdapterSlot port cpqNiclfPhysAdapterPort NT Event ID 1292 Hex 0x4435050C cpqnimsg dll Log Severity Information 1 Log Message Redundancy has been increased by the NIC in slot 1 port 2 Number of functional NICs in the team 3 SNMP Trap cpqNic3Redundancylncreased 18013 in CPQNIC MIB Symptom This trap is sent any time a previously failed physical adapter in a connected logical adapter group returns to the OK condition This trap is not sent when a logical adapter group has connectivity restored from a Failed condition The cpqNicConnectivityRestored trap is sent instead This can be caused by replacing of a faulty cable or connecting a cable that was disconnected User Action None required Supporting SNMP Trap Data e sysName e cpqHoTrapFlags e cpqNiclfPhysAdapterSlot e cpqNiclfPhysAdapterPort e cpqSiServerSystemld e cpqNiclfPhysAdapterStatus e cpqSePciSlotBoardName e cpqNiclfPhysAdapterPartNumber e ipAdEntAddr e cpqNiclflLogMaplPV Address e cpqNiclflogMapAdapterOKCount Supporting SNMP Trap Description Redundancy increased by adapter in slot
89. e e cpqHoTrapFlags e cpq SsBoxSidePanelStatus Supporting SNMP Trap Description Side panel is removed from unit NT Event ID 1102 Hex 0x4435044e cpqstmsg dll Log Severity Information 1 Event Title Storage System Side Panel In Place Log Message The side panel has been replaced on the 6 7 storage system connected to SCSI bus 5 of the controller in slot 4 SNMP Trap cpqSs3SidePanellnPlace 8012 in CPQSTSYS MIB Symptom Storage System side panel is in place The side panel status has been set to in place The storage system s side panel has returned to a properly installed state User Action None Supporting SNMP Trap Data e sysName e cpqHoTrapFlags e cpq SsBoxSidePanelStatus Supporting SNMP Trap Description Side panel is re installed on unit NT Event ID 1104 Hex 0x84350450 cpqstmsg dll Log Severity Warning 2 Event Title Storage System Fault Tolerant Power Supply Degraded Log Message The fault tolerant power supply in the 6 7 storage system connected to SCSI bus 5 of the controller in slot 4 has a degraded status Restore power or replace any failed power supply SNMP Trap cpqSs4PwrSupplyDegraded 8015 in CPQSTSYS MIB Symptom A storage system power supply status has been set to degraded User Action Restore power or replace any failed storage system power supply Supporting SNMP Trap Data e sysName Storage agents 39 e cpqHoTrapFlags e cpqSsBoxFltTolP
90. e in rack cpqRackName NT Event ID 1145 Hex 0x44350479 cpqsvmsg dll Log Severity Information 1 Event Title Enclosure Removed Log Message This trap indicates that an enclosure has been removed from the rack SNMP Trap cpgRackEnclosureRemoved 22003 in CPQRACK MIB Symptom The enclosure has been removed This trap indicates that an enclosure has been removed from the rack User Action None Supporting SNMP Trap Data e sysName e cpqHoTrapFlags e cpqRackName e cpqRackUid e cpqRackCommonEnclosureName e cpqRackCommonEnclosureModel e cpqRackCommonEnclosureSerialNum e cpqRackCommonEnclosureSparePartNumber e cpqRackCommonEnclosureTrapSequenceNum Supporting SNMP Trap Description The enclosure cpqRackCommonEnclosureName has been removed from rack cpqRackName NT Event ID 1146 Hex 0x4435047a cpqsvmsg dll Log Severity Information 1 Event Title Enclosure Inserted Log Message This trap indicates that an enclosure has been inserted into the rack SNMP Trap cpgRackEnclosurelnserted 22004 in CPQRACK MIB Symptom The enclosure has been inserted This trap indicates that an enclosure has been inserted into the rack User Action None Supporting SNMP Trap Data e sysName e cpqHoTrapFlags e cpqRackName e cpqRackUid e cpqRackCommonEnclosureName e cpqRackCommonEnclosureModel e cpqRackCommonEnclosureSerialNum e cpqRackCommonEnclosureSpa
91. e Event Log Severity Warning 2 Log Message Could not read the registry sub key 1 This error can be caused by a corrupt registry or a low memory condition Rebooting the server may correct this error Event identifier cpqhsmsg dll 4612 Hex 0x84351204 Service Event Log Severity Warning 2 Log Message Could not read from the registry sub key 1 This error can be caused by a corrupt registry or a low memory condition Rebooting the server may correct this error Event identifier cpqhsmsg dll 4613 Hex 0x84351205 Service Event Log Severity Warning 2 Log Message Could not read from the registry sub key 1 This error can be caused by a corrupt registry or a low memory condition Rebooting the server may correct this error Event identifier coqhsmsg dll 4623 Hex 0x8435120f Service Event Log Severity Warning 2 Log Message The Agent could not access WMI The WMI support may have not been started or installed Restart or Install WMI service and restart the agents Event identifier coqhsmsg dll 4624 Hex 0x84351210 Service Event Log Severity Warning 2 Log Message The Agent requires WMI service to be running If NT 4 0 installed the latest version of WMI from Microsoft WMI service may need to be started Event identifier coqhsmsg dll 4625 Hex 0x84351211 Service Event Log Severity Warning 2 Foundation agents 27 Log Message The Agent failed to initialize WMI WMI se
92. e Event Log Severity Warning 2 Log Message Could not read the registry sub key 1 This error can be caused by a corrupt registry or a low memory condition Rebooting the server may correct this error Server agents 125 Event identifier coqsvmsg dll 3332 Hex 0x84350d04 Service Event Log Severity Warning 2 Log Message Could not read the registry sub key 1 This error can be caused by a corrupt registry or a low memory condition Rebooting the server may correct this error Event identifier coqsvmsg dll 3333 Hex 0x84350d05 Service Event Log Severity Warning 2 Log Message Could not read the registry sub key 1 This error can be caused by a corrupt registry or a low memory condition Rebooting the server may correct this error Event identifier cpqsvmsg dll 3342 Hex 0x84350d0e Service Event Log Severity Warning 2 Log Message The Remote Insight Agent got an unexpected error code while waiting for multiple events The data contains the error code Event identifier coqsvmsg dll 3345 Hex 0x84350d11 Service Event Log Severity Warning 2 Log Message Remote Insight Board device driver not present The Remote Insight Agent requires the Remote Insight Board device driver CPQSM2 SYS to be installed Install the driver from the latest Software Support for Windows If you do not have a Remote Insight Board in this system disable the Remote Insight Agent via the Management Agents Co
93. e enclosure fan has been inserted User Action None Supporting SNMP Trap Data e sysName e cpqHoTrapFlags Server agents 109 e cpqRackName e cpqRackUid e cpqRackCommonEnclosureName e cpqRackCommonEnclosureSerialNum e cpqRackCommonEnclosureFanLocation e cpqRackCommonEnclosureFanSparePartNumber e cpqRackCommonEnclosureTrapSequenceNum Supporting SNMP Trap Description The enclosure cpqRackCommonEnclosureName fan in rack cpqRackName has been inserted NT Event ID 1155 Hex 0xc4350483 cpqsvmsg dll Log Severity Error 3 Event Title Rack Power Supply Failed Log Message This trap indicates that a power supply has failed SNMP Trap cpqRackPowerSupplyFailed 22013 in CPQRACK MIB Symptom The power supply status has been set to failed This trap indicates that a power supply has failed User Action Replace the power supply as soon as possible Supporting SNMP Trap Data e sysName e cpqHoTrapFlags e cpqRackName e cpqRackUid e cpqRackPowerSupplyEnclosureName e cpqRackPowerSupplySerialNum e cpqRackPowerSupplyPosition e cpqRackPowerSupplyFWRev e cpqRackPowerSupplySparePartNumber e cpgRackCommonEnclosureSerialNum e cpqRackCommonEnclosureTrapSequenceNum Supporting SNMP Trap Description The power supply cpqRackPowerSupplyPosition in enclosure cpqRackPowerSupplyEnclosureName in rack cpqRackName has been set to failed NT Event ID 1156 Hex
94. e for the specified chassis and bay location Supporting SNMP Trap Data e sysName e cpqHoTrapFlags e cpqHeFltTolPowerSupplyChassis e cpqHeFltTolPowerSupplyBay e cpqHeFltTolPowerSupplyStatus e cpqHeFltTolPowerSupplyModel e cpqHeFltTolPowerSupplySerialNumber e cpqHeFltTolPowerSupplyAutoRev e cpqHeFltTolPowerSupplyFirmwareRev e cpqHeFltTolPowerSupplySparePartNum e cpqSiServerSystemld Supporting SNMP Trap Description The Power Supply is OK on Chassis cpqHeFltTolPowerSupplyChassis Bay cpqHeFltTolPowerSupplyBay Status cpqHeFltTolPowerSupplyStatus Model cpqHeFltTolPowerSupplyModel Serial Num cpqHeFltTolPowerSupplySerialNumber Firmware cpqHeFltTolPowerSupplyFirmwareRev NT Event ID 1123 Hex 0x84350463 cpqsvmsg dll Log Severity Warning 2 Log Message Post Errors were detected One or more Power On Self Test errors were detected during server startup SNMP Trap ceqHe3PostError 6027 in CPQHLTH MIB Symptom One or more POST errors occurred Power On Self Test POST errors occur during the server restart process Server agents 96 Supporting SNMP Trap Data e sysName e cpqHoTrapFlags Supporting SNMP Trap Description Errors occurred during server restart NT Event ID 1124 Hex 0x84350464 cpqsvmsg dll Log Severity Warning 2 Log Message The Fault Tolerant Power Supply Sub system is in a degraded state Restore power or replace the failed power supply SNMP
95. e service status with the Service Control Manager The data contains the error code Event identifier coqhsmsg dll 260 Hex 0x84350104 Service Event Log Severity Warning 2 Log Message The Foundation Agents service could not create an event object The data contains the error code Event identifier cpqhsmsg dll 261 Hex 0x84350105 Service Event Log Severity Warning 2 Log Message The Foundation Agents service could not open registry key 1 The data contains the error code Event identifier coqhsmsg dll 262 Hex 0x84350106 Service Event Log Severity Warning 2 Log Message The Foundation Agents service could not start any agents successtully Event identifier cpoqhsmsg dll 263 Hex 0x84350107 Service Event Log Severity Warning 2 Log Message The Foundation Agents service could not read the registry value 1 The data contains the error code Foundation agents 6 Event identifier cpqhsmsg dll 264 Hex 0x84350108 Service Event Log Severity Warning 2 Log Message The Foundation Agents service could not load the module 1 The data contains the error code Event identifier cpqhsmsg dll 265 Hex 0x84350109 Service Event Log Severity Warning 2 Log Message The Foundation Agents service could get the control function for module 1 The data contains the error code Event identifier cpqhsmsg dll 266 Hex 0x8435010a Service Event Log Severity Warning 2
96. em Information Agent Health The DC DC Power Converter sub system has lost redundancy Replace any failed or degraded power converters SNMP Trap cpqHe3PowerConverterRedundancyLost 6045 in CPQHLTH MIB Symptom The DC DC Power Converters have lost redundancy for the specified chassis Supporting SNMP Trap Data e sysName e cpqHoTrapFlags e cpqHePwrConvChassis Supporting SNMP Trap Description The Power Converters are no longer redundant on Chassis cpqHePwrConvChassis NT Event ID 1140 Hex 0x84350474 cpqsvmsg dll Log Severity Warning 2 Server agents 102 Log Message Hot Plug PCI Board Removed A hot plug PCI adapter has been removed from the system SNMP Trap cpqSiHotPlugSlotBoardRemoved 2008 in CPQSINFO MIB Symptom Hot Plug Slot Board Removed A Hot Plug Slot Board has been removed from the specified chassis and slot User Action None Supporting SNMP Trap Data e sysName e cpqHoTrapFlags e cpqSiHotPlugSlotChassis e cpqSiHotPlugSlotIndex Supporting SNMP Trap Description Hot Plug Slot Board Removed from Chassis cpqSiHotPlugSlotChassis Slot cpqSiHotPlugSlotIndex NT Event ID 1141 Hex 0x44350475 cpqsvmsg dll Log Severity Information 1 Log Message Hot Plug PCI Board Inserted A hot plug PCI adapter has been inserted into the system SNMP Trap cpqSiHotPlugSlotBoardInserted 2009 in CPQSINFO MIB Symptom Hot Plug Slot Board Inserted A Hot Plug Slot Board has
97. ent Log Severity Warning 2 Log Message The IDE Agent got an unexpected error code while waiting for an event The data contains the error code Event identifier cpqstmsg dll 3598 Hex 0x84350e0e Service Event Log Severity Warning 2 Log Message The IDE Agent got an unexpected error code while waiting for multiple events The data contains the error code Event identifier cpqstmsg dll 3599 Hex 0x84350e0f Service Event Log Severity Warning 2 Log Message The IDE Agent did not respond to a request The data contains the error code Event identifier cpqstmsg dll 3600 Hex 0x84350e10 Service Event Log Severity Warning 2 Log Message The IDE Agent received an unknown action code from the service The data contains the action code Event identifier cpqstmsg dll 4097 Hex 0x8435 1001 Service Event Log Severity Warning 2 Log Message Could not read from the registry subkey This error can be caused by a corrupt registry or a low memory condition Rebooting the server may correct this error Event identifier cpqstmsg dll 4098 Hex 0x8435 1002 Service Event Log Severity Warning 2 Log Message Could not write the registry subkey 1 This error can be caused by a corrupt registry or a low memory condition Rebooting the server may correct this error Event identifier cpqstmsg dll 4099 Hex 0x8435 1003 Service Event Log Severity Warning 2 Log Message Could not read the registry s
98. ent has failed to refresh data associated with key 1 Check to make sure management service is up and running This may cause data received from Compaq SNMP agent to be old or invalid Event identifier cpqnimsg dll 1030 Hex 0xc4350406 Service Event Log Severity Error 3 NIC agents 133 Log Message The NIC SNMP Management Agent was unable to process a SNMP request because the Insight Agents Service is not up and running Event identifier cpqnimsg dll 1031 Hex 0x44350407 Service Event Log Severity Information 1 Log Message The NIC SNMP Management Agent has continued refreshing data for the key associated with 1 Event identifier cpqnimsg dll 1032 Hex 0x84350408 Service Event Log Severity Warning 2 Log Message Unable to read security configuration information SNMP sets have been disabled Cause This can be caused by an invalid or missing configuration or by a corrupt registry Reinstalling the Insight Agents may correct this problem Event identifier cpqnimsg dll 1033 Hex 0x44350409 Service Event Log Severity Information 1 Log Message The SNMP Insight Agent will allow SNMP sets Event identifier cpqnimsg dll 1034 Hex 0x4435040a Service Event Log Severity Information 1 Log Message The SNMP Insight Agent will not allow SNMP sets Event identifier cpqnimsg dll 1035 Hex 0xc435040b Service Event Log Severity Error 3 Log Message Unable to load a required library This error can
99. ent was unable to log an event in the event log of the system named 1 The data contains the error code Event identifier cpqstmsg dll 772 Hex 0xc4350304 Service Event Log Severity Error 3 Log Message The Remote Alerter Agent detected a null handle on initialization The data contains the error code Event identifier cpqstmsg dll 773 Hex 0xc4350305 Service Event Log Severity Error 3 Log Message The Remote Alerter Agent received an error on WaitForMultipleObjects call The data contains the error code Event identifier cpqstmsg dll 774 Hex 0xc4350306 Service Event Log Severity Error 3 Log Message The Remote Alerter Agent received an error on ResetEvent call The data contains the error code Event Identifiers 1061 1098 NT Event ID 1061 Hex 0xc4350425 cpqstmsg dll Log Severity Error 3 Event Title Drive Array Physical Drive Threshold Exceeded Log Message The physical drive in slot 4 port 5 bay 6 with serial number 7 has exceeded a drive threshold SNMP Trap cpqDa5PhyDrvThreshPassedTrap 3030 in CPQIDA MIB Symptom Physical Drive Threshold Passed This trap indicates that the agent has detected a factory threshold associated with one of the physical drive objects on a drive array has been exceeded Storage agents 32 User Action Replace the physical drive Supporting SNMP Trap Data e sysName e cpqHoTrapFlags e cpqDaPhyDrvCntlrindex e cpqDaPhyDrvBusNumber
100. es that the agent has detected a change in the status of an IDE logical drive The variable cpqldelogicalDriveStatus indicates the current logical drive status User Action If the logical drive status is failed 5 examine the array for failed drives that need replacement Supporting SNMP Trap Data e sysName e cpqHoTrapFlags e cpqldeControllerModel e cpqldeControllerSlot e cpqldelogicalDriveControllerIndex e cpqldelogicalDrivelndex e cpqldelogicalDriveStatus Supporting SNMP Trap Description Status is now cpqldeLogicalDriveStatus for the IDE logical drive NT Event ID 1188 Hex 0x843504a4 cpqstmsg dll Log Severity Warning 2 Event Title Storage System Fan Status Change Storage agents 57 Log Message An enclosure attached to port 5 of storage system 4 has a new fan status of 7 The enclosure model is 6 SNMP Trap cpqSsExBackplaneFanStatusChange 8022 in CPQSTSYS MIB Symptom Storage System Fan Status Change The agent has detected a change in the fan status of a storage system The variable cpqSsBackplaneFanStatus indicates the current fan status User Action If the fan status is degraded or failed replace any failed fans Supporting SNMP Trap Data e sysName e cpqHoTrapFlags e cpqSsChassisName e cpqSsChassisTime e cpqSsBackplanelndex e cpqSsBackplaneVendor e cpqSsBackplaneModel e cpqSsBackplaneSerialNumber e cpqSsBackplaneFanStatus Su
101. essage 1 The data contains the error code Event identifier cpqhsmsg dll 4356 Hex 0x84351104 Service Event Log Severity Warning 2 Log Message The External Status MIB Agent could not read the registry value 1 The data contains the error code Event identifier coqhsmsg dll 4357 Hex 0x84351105 Service Event Log Severity Warning 2 Log Message The External Status MIB Agent found an incorrect type for registry value 1 The data contains the type found Event identifier coqhsmsg dll 4358 Hex 0x84351106 Service Event Log Severity Warning 2 Log Message The External Status MIB Agent could not create a necessary event The data contains the error code Event identifier cpqhsmsg dll 4359 Hex 0x84351107 Service Event Log Severity Warning 2 Log Message The External Status MIB Agent could not set an event The data contains the error code Event identifier cpoqhsmsg dll 4360 Hex 0x84351108 Service Event Log Severity Warning 2 Log Message The External Status MIB Agent could not create its main thread of execution The data contains the error code Foundation agents 25 Event identifier cpqhsmsg dll 4361 Hex 0x84351109 Service Event Log Severity Warning 2 Log Message The External Status MIB Agent main thread did not terminate properly The data contains the error code Event identifier coqhsmsg dll 4362 Hex 0x84351 10a Service Event Log Severity Warning
102. esseeeeseeseeeeseeseseueeeeseeteseseeeeeeeseseseceeeeeess 64 Event Identifiers 1343 4613 aesseesssessuernurrnnrirrrrrerirrtrttittttrt ttt ttt ttet ttet teet eee eoet rer eet eSEE eSP SEES Eere E Ere Errea 77 E E E E E A A ee A E A E TEA E E E N AE E E ie tay Serene T 82 Event Identifiers 256 774 ccccccccccccccccccccccccccceececceccecccecceseceseesesscseceeeesesceeeseeeesesesseseseeeseeeseseseeeseceeeeegs 82 Event Identifiers 1024 1092 o oo ccccccccccecccccccceeccccccesccesecescesesseseseseceeesessesesesseseseseseeeseeeseeeseeeeeeeess 85 Event Identifiers 1103 1183 cccccccccccccccccccccccceceecccsecescesseeeecesssseeseeseeesesesseseeeeteeeseseseeeeeeeseseseeeseeeess 93 Event Identifiers 1539 3352 cciccccccccccccccccsccsescseesceseesseessses sess 1 e sees seseseestteesteeseesseeereeseeeseeeeees 124 Event Identifiers 5632 5684 cccccccccccccccccecccsceceeceesecesssesssessses sess sess tees seeestesstesseesteesssesteeseeeseeesees 126 Lees ce eee Meee eer ert er Meee at Corte T tent E E EE merrier erence rrr errr errr rts 129 Event Identities 256 299 c cccrccswadssisagedsazesaegeyosvasedassvagenterdascencesosdaanabis obabcvcecaideaniedooststeaaddvl euntcessiniesas 129 Event Identifiers 300 1293 P 133 Contents 3 Introduction This document contains a listing of the Microsoft Windows Server 2003 Event Log messages associated with SNMP traps which are generated by the HP Insight Management Agents for Servers fo
103. failed or degraded power supplies Supporting SNMP Trap Data e sysName e cpqHoTrapFlags e cpqRackName e cpqRackUid Server agents 120 e cpgRackCommonEnclosureSerialNum e cpqRackCommonEnclosureTrapSequenceNum Supporting SNMP Trap Description Unknown power consumption in rack cpqRackName NT Event ID 1176 Hex 0x84350498 cpqsvmsg dll Log Severity Warning 2 Event Title Power Subsystem Load Balancing Wire Missing Log Message The power subsystem load balancing wire missing SNMP Trap cpqRackPowerChassisLoacBalancingWireMissing 22034 in CPQRACK MIB Symptom Power subsystem load balancing wire missing The power subsystem load balancing wire is missing User Action Connect the load balancing wire Supporting SNMP Trap Data e sysName e cpqHoTrapFlags e cpqRackName e cpqRackUid e cpqRackCommonEnclosureName e cpqRackCommonEnclosureSerialNum e cpqRackCommonEnclosureSparePartNumber e cpqRackCommonEnclosureTrapSequenceNum Supporting SNMP Trap Description Power subsystem load balancing wire missing for enclosure cpqRackCommonEnclosureName in rack cpqRackName NT Event ID 1177 Hex 0x84350499 cpqsvmsg dll Log Severity Warning 2 Event Title Power Subsystem Too Many Power Enclosures Log Message The maximum number of power enclosures has been exceeded SNMP Trap cpqRackPowerChassisTooManyPowerChassis 22035 in CPQRACK MIB Symptom Power subsystem has
104. g NT Event ID 1212 Hex 0x843504bc cpqstmsg dll Log Severity Warning 2 Event Title Storage System Fan Status Change Log Message The 6 7 storage system connected to SCSI bus 5 of the controller in 4 has a new status of 2 SNMP Trap cpqSs5FanStatusChange 8026 in CPQSTSYS MIB Symptom Storage System fan status change The agent has detected a change in the Fan Status of a storage system The variable cpqSsBoxFanStatus indicates the current fan status User Action If the fan status is degraded or failed replace any failed fans Supporting SNMP Trap Data e sysName e cpqHoTrapFlags Storage agents 70 e cpgSsBoxCntlrHwLocation e cpqSsBoxCntlrindex e cpqSsBoxBuslndex e cpqSsBoxVendor e cpqSsBoxModel e cpqSsBoxSerialNumber e cpqSsBoxFanStatus Supporting SNMP Trap Description Storage System fan status changed to cpqSsBoxFanStatus NT Event ID 1213 Hex 0x843504bd cpqstmsg dll Log Severity Warning 2 Event Title Storage System Temperature Status Change Log Message The 6 7 storage system connected to SCSI bus 5 of the controller in 4 has a new temperature status of 2 SNMP Trap cpqSs5TempStatusChange 8027 in CPQSTSYS MIB Symptom Storage System Temperature Status Change The agent has detected a change in the temperature status of a storage system The variable coqSsBoxTempStatus indicates the current temperature status User Action If the temper
105. g Message A Temperature Sensor Condition has been set to degraded The system may or may not shut down depending on the state of the thermal degraded action value 6 SNMP Trap cpqHe3TemperatureDegraded 6041 in CPQHLTH MIB Symptom The temperature status has been set to degraded in the specified chassis and location The server s temperature is outside of the normal operating range The server is shut down if the cpqHeThermalDegradedAction variable is set to shutdown 3 Supporting SNMP Trap Data e sysName e cpqHoTrapFlags e cpqHeThermalDegradedAction e cpqHeTemperatureChassis e cpqHeTemperatureLocale Supporting SNMP Trap Description Temperature out of range on Chassis cpqHeTemperatureChassis Location cpqHeTemperatureLocale Shutdown may occur NT Event ID 1136 Hex 0x44350470 cpqsvmsg dll Log Severity Information 1 Log Message A Temperature Sensor Condition has been set to OK The system s temperature has returned to the normal operating range SNMP Trap cpqHe3TemperatureOk 6042 in CPQHLTH MIB Symptom The temperature status has been set to OK in the specified chassis and location The server s temperature has returned to the normal operating range Supporting SNMP Trap Data e sysName e cpqHoTrapFlags e cpqHeTemperatureChassis e cpqHeTemperatureLocale Supporting SNMP Trap Description Temperature Normal on Chassis cpqHeTemperatureChassis Location cpqHeTemperatureLo
106. g Message Could not delete the registry key 1 This error can be caused by a corrupt registry or a low memory condition Rebooting the server may correct this error NIC agents 129 Event identifier cpqnimsg dll 264 Hex 0x84350108 Service Event Log Severity Warning 2 Log Message Unable to open the registry key 1 This error can be caused by a corrupt registry or a low memory condition Rebooting the server may correct this error Event identifier cpqnimsg dll 265 Hex 0x84350109 Service Event Log Severity Warning 2 Log Message Unable to read 1 from the registry This error can be caused by a corrupt registry or a low memory condition Rebooting the server may correct this error Event identifier cpqnimsg dll 266 Hex 0x8435010a Service Event Log Severity Warning 2 Log Message Unable to read 1 from the registry This error can be caused by a corrupt registry or a low memory condition Rebooting the server may correct this error Event identifier cpqnimsg dll 267 Hex 0x8435010b Service Event Log Severity Warning 2 Log Message Unable to write 1 to the registry This error can be caused by a corrupt registry or a low memory condition Rebooting the server may correct this error Event identifier cpqnimsg dll 268 Hex 0x8435010c Service Event Log Severity Warning 2 Log Message Unable to enumerate 1 from the registry This error can be caused by a cor
107. g SNMP Trap Description Spare Status is now cpqDaSpareStatus Storage agents 73 NT Event ID 1218 Hex 0x843504c2 cpqstmsg dll Log Severity Warning 2 Event Title Storage System Fan Status Change Log Message The 6 7 storage system connected to 5 of the controller in 4 has a new status of 2 SNMP Trap cpqSs6FanStatusChange 8029 in CPQSTSYS MIB Symptom Storage System Fan Status Change The agent has detected a change in the fan status of a storage system The variable cpqSsBoxFanStatus indicates the current fan status User Action If the fan status is degraded or failed replace any failed fans Supporting SNMP Trap Data e sysName e cpqHoTrapFlags e cpqSsBoxCntlrHwLocation e cpqSsBoxCntlrindex e cpqSsBoxBuslndex e cpqSsBoxVendor e cpqSsBoxModel e cpqSsBoxSerialNumber e cpqSsBoxFanStatus e cpqSsBoxlocationString Supporting SNMP Trap Description Storage System fan status changed to cpqSsBoxFanStatus NT Event ID 1219 Hex 0x843504c3 cpqstmsg dll Log Severity Warning 2 Event Title Storage System Temperature Status Change Log Message The 6 7 storage system connected to 5 of the controller in 4 has a new temperature status of 2 SNMP Trap cpgSs6TempStatusChange 8030 in CPQSTSYS MIB Symptom Storage System Temperature Status Change The agent has detected a change in the temperature status of a storage system The variable cpoqSsBoxTempStatus indicates
108. gical Drive Status Change The Storage Agent has detected a change in the status of a SAS or SATA logical drive The current logical drive status is indicated in the coqSasLogDrvStatus variable Supporting SNMP Trap Data e sysName e cpqHoTrapFlags e cpgSasHbaHwLocation e cpqSaslogDrvHbalndex e cpqSaslogDrvindex e cpqSaslogDrvStatus e cpqSaslogDrvOsName Supporting SNMP Trap Description Status is now cpqSasLogDrvStatus Event identifier cpqstmsg dll 1280 Hex 0x84350500 Service Event Log Severity Warning 2 Log Message Unable to allocate memory This indicates a low memory condition Rebooting the system will correct this error Event identifier cpqstmsg dll 1281 Hex 0x84350501 Service Event Log Severity Warning 2 Log Message Could not read from the registry subkey This error can be caused by a corrupt registry or a low memory condition Rebooting the server may correct this error Event identifier cpqstmsg dll 1282 Hex 0x84350502 Service Event Log Severity Warning 2 Log Message Could not write the registry subkey 1 This error can be caused by a corrupt registry or a low memory condition Rebooting the server may correct this error Storage agents 76 Event identifier cpqstmsg dll 1283 Hex 0x84350503 Service Event Log Severity Warning 2 Log Message Could not read the registry subkey 1 This error can be caused by a corrupt registry or a low memory
109. h SCSI target 6 connected to SCSI bus 5 of the controller in slot 4 has a new status of 2 SNMP Trap cpqScsiCdLibraryStatusChange 5015 in CPQSCSI MIB Symptom CD Library Status Change The Insight Agent has detected a change in the status of a CD Library device The current CD Library status is indicated in the cpqScsiCdLibraryStatus variable Supporting SNMP Trap Data e sysName e cpqHoTrapFlags e cpqCdLibraryCntlrindex e cpqCdLibraryBusIndex e cpqCdlibraryScsildIndex e cpqCdLibraryStatus Supporting SNMP Trap Description Status is now cpqCdLibraryStatus NT Event ID 1164 Hex 0x8435048c cpqstmsg dll Log Severity Warning 2 Event Title Drive Array Controller Status Change Log Message The Drive Array Controller in slot 4 has a new status of 5 SNMP Trap cpqDa5CnitlrStatusChange 3028 in CPQIDA MIB Storage agents 49 Symptom Controller Status Change This trap indicates that the agent has detected a change in the status of a drive array controller The variable coqDaCntlrBoardStatus indicates the current controller status User Action If the board status is generalFailure 3 you may need to replace the controller If the board status is cableProblem 4 check the cable connections between the controller and the storage system Supporting SNMP Trap Data e sysName e cpqHoTrapFlags e cpqDaCntlrSlot e cpqDaCntlrBoardStatus e cpqDaCntlrModel e cpqDaCntlrSerialNumber e
110. has been set to failed NT Event ID 1151 Hex 0x8435047F cpqsvmsg dll Log Severity Warning 2 Event Title Rack Enclosure Fan Degraded Log Message This trap indicates that an enclosure fan has failed but other fans in the redundant fan group are still operating This may result in overheating of the enclosure SNMP Trap cpqRackEnclosureFanDegraded 22009 in CPQRACK MIB Symptom The enclosure fan status has been set to degraded This trap indicates that an enclosure fan has failed but that other fans in the redundant fan group are still operating This may result in the enclosure overheating User Action Replace the fan as soon as possible Supporting SNMP Trap Data e sysName e cpqHoTrapFlags e cpqRackName e cpqRackUid e cpqRackCommonEnclosureName e cpqRackCommonEnclosureSerialNum e cpqRackCommonEnclosureFanLocation e cpqRackCommonEnclosureFanSparePartNumber e cpqRackCommonEnclosureTrapSequenceNum Supporting SNMP Trap Description The enclosure cpqRackCommonEnclosureName fan in rack cpqRackName has been set to degraded NT Event ID 1152 Hex 0x44350480 cpqsvmsg dll Log Severity Information 1 Event Title Rack Enclosure Fan OK Log Message This trap indicates that an enclosure fan has returned to normal operation SNMP Trap cpqRackEnclosureFanOk 22010 in CPQRACK MIB Symptom The enclosure fan status has been set to OK This trap indicates that an enclosure fan has returne
111. has detected a memory fault Advanced ECC has been activated Schedule server down time to replace the memory SNMP Trap cpqHeResilientAdvancedECCMemoryEngaged 6052 in CPQHLTH MIB Symptom Advanced Memory Protection Advanced ECC Memory Engaged The Advanced Memory Protection subsystem has detected a memory fault Advanced ECC has been activated User Action Replace the faulty memory Supporting SNMP Trap Data e sysName e cpqHoTrapFlags Supporting SNMP Trap Description The Advanced Memory Protection subsystem has engaged the advanced ECC memory NT Event ID 1028 Hex 0x84350404 cpqsvmsg dll Log Severity Warning 2 Log Message The Advanced Memory Protection sub system has detected a memory fault The XOR recovery engine has been activated Schedule server down time to replace the memory SNMP Trap cpqHeResilientMemXorMemoryEngaged 6053 in CPQHLTH MIB Symptom Advanced Memory Protection XOR Engine Memory Engaged The Advanced Memory Protection subsystem has detected a memory fault The XOR engine has been activated User Action Replace the faulty memory Supporting SNMP Trap Data e sysName e cpqHoTrapFlags Supporting SNMP Trap Description The Advanced Memory Protection subsystem has engaged the XOR memory NT Event ID 1029 Hex 0x44350405 cpqsvmsg dll Log Severity Information 1 Log Message The Fault Tolerant Power Supply Sub system has returned to a redundant state SNMP Trap cpq
112. he state Event identifier cpqstmsg dll 269 Hex 0x8435010d Service Event Log Severity Warning 2 Log Message The Storage Agents service could not stop agent 1 The data contains the error code Event identifier cpqstmsg dll 270 Hex 0x8435010e Service Event Log Severity Warning 2 Log Message The Storage Agents service could not terminate agent 1 The data contains the error code Event identifier cpqstmsg dll 271 Hex 0x8435010f Service Event Log Severity Warning 2 Log Message The Storage Agents service could not unload the module 1 The data contains the error code Event identifier cpqstmsg dll 272 Hex 0x843501 10 Service Event Log Severity Warning 2 Log Message The Storage Agents service could not create the registry key 1 The data contains the error code Event identifier cpqstmsg dll 273 Hex 0x84350111 Service Event Log Severity Warning 2 Log Message The Storage Agents service could not write the registry value 1 The data contains the error code Event identifier cpqstmsg dll 399 Hex 0xc435018f Service Event Log Severity Error 3 Storage agents 30 Log Message The Storage Agents service encountered a fatal error The service is terminating The data contains the error code Event identifier cpqstmsg dll 400 Hex 0x44350190 Service Event Log Severity Information 1 Log Message The Storage Agents service version 1 has
113. his error can be caused by a corrupt registry or a low memory condition Rebooting the server may correct this error Event identifier coqhsmsg dll 2051 Hex 0x84350803 Service Event Log Severity Warning 2 Log Message Unable to read from the registry This error can be caused by a corrupt registry or a low memory condition Rebooting the server may correct this error Event identifier cpqhsmsg dll 2052 Hex 0x84350804 Service Event Log Severity Warning 2 Log Message Unable to read 1 from the registry This error can be caused by a corrupt registry or a low memory condition Rebooting the server may correct this error Event identifier cpqhsmsg dll 2053 Hex 0x84350805 Service Event Log Severity Warning 2 Log Message Unable to read 1 from the registry This error can be caused by a corrupt registry or a low memory condition Rebooting the server may correct this error Event identifier cpqhsmsg dll 2056 Hex 0x84350808 Service Event Log Severity Warning 2 Log Message Unable to create thread This error can be caused by a low memory condition Rebooting the server may correct this error Event identifier coqhsmsg dll 2098 Hex 0x84350832 Service Event Log Severity Warning 2 Log Message Unable to acquire file system information This error can be caused by an unformatted partition or by a partition that has been recently modified Formatting the partition or rebooting the server
114. horizedLoginAttempts 9003 in CPQSM2 MIB Symptom Remote Insight Integrated Lights Out Unauthorized Login Attempts The Remote Insight Integrated Lights Out firmware has detected unauthorized login attempts Supporting SNMP Trap Data e sysName e cpqHoTrapFlags e cpqSm2CntlrBadLoginAttemptsThresh Supporting SNMP Trap Description More than cpqSm2CntlrBadLoginAttemptsThresh unauthorized login attempts detected NT Event ID 1109 Hex 0xc4350455 cpqsvmsg dll Log Severity Error 3 Log Message The Remote Insight Board has detected a battery failure SNMP Trap cpqSm2BatteryFailed 9004 in CPQSM2 MIB Symptom Remote Insight Battery Failed The Remote Insight battery has failed and needs to be replaced Supporting SNMP Trap Data e sysName e cpqHoTrapFlags Supporting SNMP Trap Description Remote Insight battery failed NT Event ID 1110 Hex 0xc4350456 cpqsvmsg dll Log Severity Error 3 Server agents 93 Log Message The Remote Insight Board has detected self test error 4 SNMP Trap cpqSm2SelfTestError 9005 in CPQSM2 MIB Symptom Remote Insight Integrated Lights Out Self Test Error The Remote Insight Integrated Lights Out firmware has detected a Remote Insight self test error Supporting SNMP Trap Data e sysName e cpqHoTrapFlags e cpqSm2CntlrSelfTestErrors Supporting SNMP Trap Description Remote Insight Integrated Lights Out self test error cpqSm2CnilrSelfTestErro
115. iLun Storage agents 68 e cpqDaTapeLibraryModel e cpqDaTapeLibraryFWRev e cpqDaTapelLibrarySerialNumber e cpqDaTapeLibraryDoorStatus Supporting SNMP Trap Description The door is cpqDaTapelibraryDoorStatus for tape library NT Event ID 1209 Hex 0x843504b9 cpqstmsg dll Log Severity Warning 2 Event Title Drive Array Tape Drive Status Change Log Message The tape drive in 4 SCSI bus 5 SCSI target 6 has a new status of 7 SNMP Trap cpqDa TapeDriveStatusChange 3043 in CPQIDA MIB Symptom Tape Drive Status Change This trap indicates that the agent has detected a change in the status of a tape drive The variable coqDaTapeDrvStatus indicates the current tape status The variable cpqDaTapeDrvScsildIndex indicates the SCSI ID of the tape drive User Action If the tape is failed check the tape and all SCSI connections Supporting SNMP Trap Data e sysName e cpqHoTrapFlags e cpqDaCntlrHwLocation e cpqDaTapeDrvCntlrindex e cpqDaTapeDrvBuslndex e cpqDaTapeDrvScsildIndex e cpqDaTapeDrvLunlndex e cpqDaTapeDrvyName e cpqDaTapeDrvFwRev e cpqDaTapeDrvSerialNumber e cpq DaTapeDrvStatus Supporting SNMP Trap Description Status is now cpqDaTapeDrvStatus for a tape drive NT Event ID 1210 Hex 0x843504ba cpqstmsg dll Log Severity Warning 2 Event Title Drive Array Tape Drive Cleaning Required Log Message The tape drive in 4 SCSI bus 5 SCSI target 6 requires cleaning
116. iled 16019 in CPQFCA MIB Symptom External Array Accelerator Board Battery failed This trap indicates that the agent has detected a battery failure associated with the Array Accelerator Cache Board User Action Replace the Accelerator Cache Board Supporting SNMP Trap Data e sysName Storage agents 44 e cpqHoTrapFlags e cpqSsChassisName e cpqSsChassisTime e cpqFcaAccelBoxloSlot e cpqFcaCntlrModel e cpqFcaAccelSerialNumber e cpqFcaAccelTotalMemory Supporting SNMP Trap Description Battery status is failed NT Event ID 1151 Hex 0xc435047f cpqstmsg dil Log Severity Error 3 Event Title External Array Controller Status Change Log Message The external controller in O slot 5 of array 4 has a new status of 6 SNMP Trap cpqFca2CntlrStatusChange 16020 in CPQFCA MIB Symptom External Array Controller Status Change This trap indicates that the agent has detected a change in the status of an External Array Controller The variable cpqFcaCntlrStatus indicates the current controller status User Action If the controller status is offline 4 access to the storage box has been lost Check the storage box and all fibre channel connections for problems Supporting SNMP Trap Data e sysName e cpqHoTrapFlags e cpqSsChassisName e cpqSsChassisTime e cpqFcaCntlrBoxloSlot e cpqFcaCntlrStatus e cpqFcaCntlrModel e cpqFcaCntlrSerialNumber e cpqFcaAccelTotalMemory Su
117. ined within the variable list are those of the alarm entry that generated this trap Supporting SNMP Trap Data e sysName e cpqHoTrapFlags e cpqMeAlarmVariable e cpqMeAlarmSampleType e cpqMeAlarmValue e cpqMeAlarmFallingThreshold e cpqMeAlarmOwner e cpqMeAlarmSeverity e cpqMeAlarmExtendedDescription Supporting SNMP Trap Description cpgMeAlarmOwner Variable cpqMeAlarmVariable has value cpqMeAlarmValue lt cpqMeAlarmFallingThreshold NT Event ID 1164 Hex 0x8435048c cpqhsmsg dll Log Severity Warning 2 Log Message Critical Rising Threshold Passed SNMP Trap cpqMeCriticalRisingAlarmExtended 10007 in CPQTHRSH MIB Symptom Critical Rising Threshold passed An alarm entry has crossed its critical rising threshold The instances of those objects contained within the variable list are those of the alarm entry that generated this trap Supporting SNMP Trap Data e sysName e cpqHoTrapFlags e cpqMeAlarmVariable e cpqMeAlarmSampleType e cpqMeAlarmValue Foundation agents 10 e cpqMeAlarmRisingThreshold e cpqMeAlarmOwner e cp MeAlarmSeverity e cpqMeAlarmExtendedDescription Supporting SNMP Trap Description cpqMeAlarmOwner Variable cpqMeAlarmVariable has value cpqMeAlarmValue lt cpqMeAlarmRisingThreshold NT Event ID 1165 Hex 0x8435048d cpqhsmsg dll Log Severity Warning 2 Log Message Critical Falling Threshold Pa
118. istry value 1 The data contains the type found Event identifier cpqstmsg dll 3590 Hex 0x84350e06 Service Event Log Severity Warning 2 Log Message The IDE Agent could not create an event The data contains the error code Event identifier cpqstmsg dll 3591 Hex 0x84350e07 Service Event Log Severity Warning 2 Log Message The IDE Agent could not open an event The data contains the error code Event identifier cpqstmsg dll 3592 Hex 0x84350e08 Service Event Log Severity Warning 2 Log Message The IDE Agent could not set an event The data contains the error code Event identifier cpqstmsg dll 3593 Hex 0x84350e09 Service Event Log Severity Warning 2 Log Message The IDE Agent could not create a mutex The data contains the error code Event identifier cpqstmsg dll 3594 Hex 0x84350e0a Service Event Log Severity Warning 2 Log Message The IDE Agent could not open a mutex The data contains the error code Event identifier cpqstmsg dll 3595 Hex 0x84350e0b Service Event Log Severity Warning 2 Storage agents 79 Log Message The IDE Agent could not create its main thread of execution The data contains the error code Event identifier cpqstmsg dll 3596 Hex 0x84350e0c Service Event Log Severity Warning 2 Log Message The IDE Agent main thread did not terminate properly The data contains the error code Event identifier cpqstmsg dll 3597 Hex 0x84350e0d Service Ev
119. ity Warning 2 Foundation agents 7 Log Message The Foundation Agents service could not write the registry value 1 The data contains the error code Event identifier coqhsmsg dll 399 Hex 0xc435018f Service Event Log Severity Error 3 Log Message The Foundation Agents service encountered a fatal error The service is terminating The data contains the error code Event identifier cpqhsmsg dll 400 Hex 0x44350190 Service Event Log Severity Information 1 Log Message The Foundation Agents service version 1 has started Event identifier cpoqhsmsg dll 401 Hex 0x44350191 Service Event Log Severity Information 1 log Message 1 Event identifier cpqhsmsg dll 402 Hex 0x44350192 Service Event Log Severity Information 1 Log Message The Foundation Agents could not find the SNMP service Please install the SNMP service to enabled remote management of the server Event identifier cpqhsmsg dll 768 Hex 0x84350300 Service Event Log Severity Warning 2 Log Message The Host Remote Alerter detected an invalid data type within an alert definition Event identifier coqhsmsg dll 769 Hex 0x84350301 Service Event Log Severity Warning 2 Log Message The Host Remote Alerter detected an error while attempting to log an alert remotely The data contains the error code Event identifier cpqhsmsg dll 770 Hex 0x84350302 Service Event Log Severity Warning 2 Log Message The Host Remo
120. ll 3867 Hex 0x44350f1b Service Event Log Severity Information 1 Log Message Resource status is offline pending The resource is being taken offline Event identifier cpqhsmsg dll 3868 Hex 0x84350f1c Service Event Log Severity Warning 2 Log Message Cluster information is unavailable The Cluster service may not be running Try to restart the Cluster service Event identifier cpqhsmsg dll 3869 Hex 0x84350f1d Service Event Log Severity Warning 2 Log Message The Cluster service is not running The Cluster service has failed or has not started yet Try to restart the cluster service Event identifier coqhsmsg dll 3870 Hex 0x84350f1le Service Event Log Severity Warning 2 Log Message The Agent could not open the Cluster service The Cluster service may have been stopped Try to restart the cluster service Event identifier cpqhsmsg dll 3871 Hex 0x84350f1f Service Event Log Severity Warning 2 Log Message The Agent could not open the Cluster service registry key Event identifier cpqhsmsg dll 3872 Hex 0x84350f20 Service Event Log Severity Warning 2 Log Message The specified storage class is not supported by the Agent The Agent only supports the disk resource class Event identifier coqhsmsg dll 3873 Hex 0x84350f21 Service Event Log Severity Warning 2 Log Message The fibre controller resided at the storage box is off line The Agent only supports the disk resource class
121. loSlot e cpqFcaAccelStatus e cpqFcaCntlrModel e cpqFcaAccelSerialNumber e cpqFcaAccelTotalMemory e cpqFcaAccelErrCode Supporting SNMP Trap Description Status is now cpqFcaAccelStatus NT Event ID 1149 Hex 0xc435047d cpqstmsg dil Log Severity Error 3 Event Title External Array Accelerator Bad Data Log Message The array accelerator board attached to the external controller in O slot 5 of array 4 is reporting that it contains bad cached data SNMP Trap cpqFca2AccelBadDataTrap 16018 in CPQFCA MIB Symptom External Array Accelerator Board Bad Data This trap indicates that the agent has detected an Array Accelerator Cache Board that has lost battery power If data was being stored in the accelerator memory when the system lost power that data has been lost User Action Verify that no data has been lost Supporting SNMP Trap Data e sysName e cpqHoTrapFlags e cpqSsChassisName e cpqSsChassisTime e cpqFcaAccelBoxloSlot e cpqFcaCntlrModel e cpqFcaAccelSerialNumber e cpqFcaAccelTotalMemory Supporting SNMP Trap Description Accelerator lost battery power Data Loss possible NT Event ID 1150 Hex 0xc435047e cpqstmsg dll Log Severity Error 3 Event Title External Array Accelerator Battery Failed Log Message The array accelerator board attached to the external controller in I O slot 5 of array 4 is reporting a battery failure SNMP Trap cpqFca2AccelBatteryFa
122. logical adapter group returns to the OK condition This can be caused by replacement of a faulty cable or re attaching a cable that was unplugged User Action None required Supporting SNMP Trap Data e sysName e cpqHoTrapFlags e cpqNiclfPhysAdapterSlot e cpqNiclfPhysAdapterPort e cpqSiServerSystemld e cpqNiclfPhysAdapterStatus e cpqSePciSlotBoardName e cpqNiclfPhysAdapterPartNumber e ipAdEntAddr e cpqNiclfLogMaplPV Address Supporting SNMP Trap Description Connectivity is restored for adapter in slot cpqNiclfPhysAdapterSlot port cpqNiclfPhysAdapterPort NT Event ID 1291 Hex 0xc435050B cpqnimsg dll Log Severity Error 3 Log Message Connectivity has been lost for the NIC in slot 1 port 2 SNMP Trap ceqNic3ConnectivityLost 18012 in CPQNIC MIB Symptom This trap is sent any time the status of a logical adapter changes to the Failed condition This occurs when the adapter in a single adapter configuration fails or when the last adapter in a redundant configuration fails This can be caused by loss of link due to a cable being removed from the adapter or the Hub or Switch Internal adapter Hub or Switch failures can also cause this condition User Action Check the cables to the adapter and the Hub or Switch If no cable problems are found the adapter Hub or Switch may need replacement Supporting SNMP Trap Data e sysName NIC agents 136 e cpqHoTrapFlags
123. logicalDisklIndex e cpqOslogicalDisklnstance e cpqOslogicalDiskBusyTimePercent Supporting SNMP Trap Description The LogicalDisk performance instance cpqOsLogicalDiskInstance is degraded with DiskBusyTime of cpqOsLogicalDiskBusyTimePercent percent NT Event ID 1180 Hex 0xc435049c cpghsmsg dll Log Severity Error 3 Log Message The Logical Disk Performance Instance 4 is failed with Disk Busy Time of 5 percent SNMP Trap cpqOsLogicalDiskBusyTimeFailed 19008 in CPQWINOS MIB Symptom The LogicalDisk BusyTime performance property is set to critical Supporting SNMP Trap Data e sysName e cpqHoTrapFlags e cpqOslogicalDisklIndex e cpqOslogicalDisklnstance e cpqOslogicalDiskBusyTimePercent Supporting SNMP Trap Description The LogicalDisk performance instance cpqOsLogicalDiskInstance is critical with DiskBusyTime of cpqOsLogicalDiskBusyTimePercent percent NT Event ID 1181 Hex 0xc435049d cpqhsmsg dll Log Severity Error 3 Log Message 4 SNMP Trap cpqHoCriticalSoftwareUpdateTrap 11014 in CPQHOST MIB Symptom This trap is sent to notify the user of a Critical Software Update Supporting SNMP Trap Data e sysName Foundation agents 16 e cpqHoTrapFlags e cpqHoCriticalSoftwareUpdateData Supporting SNMP Trap Description cpqHoCriticalSoftwareUpdateData Event identifier coqhsmsg dll 1792 Hex 0x84350700 Service Event Log Severity Warning 2 Log Me
124. m e cp HeResMem2ModuleNum e cpqHeResMem2ModulePartNo e cp HeResMem2ModuleSize e cpqSiServerSystemld Supporting SNMP Trap Description Correctable memory errors require a replacement of the memory module in slot cpqHeResMem2BoardNum socket cpqHeResMem2ModuleNum Cpu cpqHeResMem2CpuNun Riser cpqHeResMem2RiserNum NT Event ID 1036 Hex 0x4435040CL cpqsvmsg dll Log Severity Informational 1 Log Message A memory board or cartridge has been removed from the system Please reinsert the memory board or cartridge SNMP Trap cpqHe5ResMemBoardRemoved 6065 in CPQHLTH MIB Symptom Memory board or cartridge or riser removed An Advanced Memory Protection sub system board or cartridge or riser has been removed from the system Value O for CPU means memory is not processor based Server agents 87 User Action Be sure that the board cartridge or riser memory is installed correctly and then re install the memory board cartridge or processor Supporting SNMP Trap Data e sysName e cpqHoTrapFlags e cpqHeResMem2BoardSlotNum e cpqHeResMem2BoardCpuNum e cpqHeResMem2BoardRiserNum Supporting SNMP Trap Description Memory Board or Cartridge Removed from Slot cpqHeResMem2BoardSlotNum Cpu cpqHeResMem2BoardCpuNum Riser cpqHeResMem2BoardRiserNum NT Event ID 1037 Hex 0x4435040DL cpqsvmsg dll Log Severity Informational 1 Log Message System Information Agent Health A memory bo
125. may correct this error Event identifier cpqhsmsg dll 2099 Hex 0x84350833 Service Event Log Severity Warning 2 Log Message Unable to acquire file system information for 1 This error can be caused by a low memory condition Rebooting the server may correct this error Event identifier cpqhsmsg dll 2100 Hex 0x84350834 Service Event Log Severity Warning 2 Foundation agents 18 Log Message Unable to acquire the current process list This error can be caused by a low memory condition Rebooting the server may correct this error Event identifier cpqhsmsg dll 2101 Hex 0x84350835 Service Event Log Severity Warning 2 Log Message Unable to acquire the CPU performance data This error can be caused by a low memory condition Rebooting the server may correct this error Event identifier cpoqhsmsg dll 2304 Hex 0x84350900 Service Event Log Severity Warning 2 Log Message The Threshold Agent could not allocate memory The data contains the error code Event identifier coqhsmsg dll 2305 Hex 0x84350901 Service Event Log Severity Warning 2 Log Message The Threshold Agent could not open the base of the registry The data contains the error code Event identifier coqhsmsg dll 2306 Hex 0x84350902 Service Event Log Severity Warning 2 Log Message 1 The data contains the error code Event identifier cpqhsmsg dll 2307 Hex 0x84350903 Service Event Log Severity Warning 2 Log
126. n If the power supply status is failed restore power or replace the failed power supply Supporting SNMP Trap Data e sysName e cpqHoTrapFlags e cpqSsChassisName e cpqSsChassisTime e cpqSsPowerSupplyBay e cpqSsPowerSupplyStatus e cpqSsPowerSupplySerialNumber e cpqSsPowerSupplyBoardRevision e cpqSsPowerSupplyFirmwareRevision Supporting SNMP Trap Description Storage system power supply status changed to cpqSsPowerSupplyStatus NT Event ID 1154 Hex 0x84350482 cpqstmsg dil Log Severity Warning 2 Event Title Storage System Power Supply UPS Status Change Log Message The UPS attached to storage system 4 power supply bay 5 has a new status of 7 SNMP Trap cpqSsExPowerSupplyUpsStatusChange 8018 in CPQSTSYS MIB Symptom Storage system power supply UPS status change The agent has detected a change status of a UPS attached to a storage system power supply The variable cpqSsPowerSupplyUpsStatus indicates the current status User Action If the UPS status is powerFailed 4 or batteryLow 5 restore power to the UPS Supporting SNMP Trap Data e sysName Storage agents 46 e cpqHoTrapFlags e cpqSsChassisName e cpqSsChassisTime e cpqSsPowerSupplyBay e cpqSsPowerSupplyUpsStatus Supporting SNMP Trap Description Storage system power supply UPS status changed to cpqSsPowerSupplyUpsStatus NT Event ID 1155 Hex 0x84350483 cpqstmsg dll Log Severity Warni
127. nclosure temperature sensor has been tripped indicating a possible overheat condition SNMP Trap cpqRackEnclosureTempDegraded 22006 in CPQRACK MIB Symptom The enclosure temperature status has been set to degraded This trap indicates that an enclosure temperature sensor has been tripped indicating a possible overheat condition User Action Shut down the enclosure and possibly the rack as soon as possible Be sure that all fans are working properly and that air flow in the rack has not been blocked Supporting SNMP Trap Data e sysName e cpqHoTrapFlags e cpqRackName e cpqRackUid e cpqRackCommonEnclosureName Server agents 106 e cpgRackCommonEnclosureSerialNum e cpqRackCommonEnclosureTempLocation e cpqRackCommonEnclosureSparePartNumber e cpqRackCommonEnclosureTrapSequenceNum Supporting SNMP Trap Description The enclosure cpqRackCommonEnclosureName temperature sensor in rack cpqRackName has been set to degraded NT Event ID 1149 Hex 0x4435047d cpqsvmsg dll Log Severity Information 1 Event Title Rack Enclosure Temperature Normal Log Message This trap indicates that an enclosure temperature sensor has returned to normal SNMP Trap cpqRackEnclosureTempOk 22007 in CPQRACK MIB Symptom The enclosure temperature status has been set to OK This trap indicates that an enclosure temperature sensor has returned to normal User Action None Supporting SNMP Trap Data e sysName
128. ng 2 Event Title Storage System Temperature Sensor Status Change Log Message Storage system 4 temperature sensor at location 5 has a new status of 6 and a current temperature value of 7 celsius SNMP Trap cpqSsExTempSensorStatusChange 8019 in CPQSTSYS MIB Symptom Storage system temperature sensor status change The agent has detected a change in the status of a storage system temperature sensor The variable cpqSsTempSensorStatus indicates the current status User Action If the temperature status is degraded or failed shut down the storage system as soon as possible Be sure that the storage system environment is being cooled properly and that no components are overheated Supporting SNMP Trap Data e sysName e cpqHoTrapFlags e cpqSsChassisName e cpqSsChassisTime e cpaqSsTempSensorLocation e cpqSsTempSensorStatus e cpqSsTempSensorCurrentValue Supporting SNMP Trap Description Storage system temperature sensor status changed to cpqSsTempSensorStatus NT Event ID 1156 Hex 0x84350484 cpqstmsg dll Log Severity Warning 2 Event Title SCSI Tape Library Failed Log Message The SCSI tape library with SCSI target 6 connected to SCSI bus 5 of the controller in slot 4 has encountered an error SNMP Trap cpqTape3LibraryFailed 5010 in CPQSCSI MIB Symptom Tape Library Error The Insight Agent has detected that an autoloader unit has encountered an error Supporting SNMP Trap
129. ng SNMP Trap Data e sysName e cpqHoTrapFlags e cpgFcTapeCntlhWWN e cpqFcTapeDriveScsiBus e cpqFcTapeDriveScsiTarget e cpqFcTapeDriveScsilun Supporting SNMP Trap Description Cleaning is needed for tape drive NT Event ID 1178 Hex 0x8435049a cpqstmsg dll Log Severity Warning 2 Event Title Fibre Channel Tape Drive Replace Cleaning Tape Log Message The cleaning tape in the Fibre Channel tape drive on tape controller with world wide name 4 SCSI bus 5 SCSI target 6 needs to be replaced SNMP Trap cpgFcTapeDriveCleanTapeReplace 16013 in CPQFCA MIB Symptom Fibre Channel Tape Drive Cleaning Tape Needs Replacing The agent has detected that an autoloader tape unit has a cleaning tape that has been fully used and therefore needs to be replaced with a new cleaning tape Supporting SNMP Trap Data e sysName e cpqHoTrapFlags e cpgFcTapeCntlhWWN e cpqFcTapeDriveScsiBus e cpqFcTapeDriveScsiTarget e cpqFcTapeDriveScsilun Supporting SNMP Trap Description Cleaning tape needs replacing NT Event ID 1179 Hex 0x8435049b cpqstmsg dll Log Severity Warning 2 Event Title External Array Controller Active Log Message The external controller in I O slot 5 of array 4 has become the active controller SNMP Trap cpqFcaCntlrActive 16014 in CPQFCA MIB Symptom Fibre Array Controller Active This trap indicates that the Storage Agent has detected that a backup arra
130. ntrol Panel Event identifier cpqsvmsg dll 3351 Hex 0x84350d17 Service Event Log Severity Warning 2 Log Message The shared memory interface has been reset Event identifier cpqsvmsg dll 3352 Hex 0xc4350d18 Service Event Log Severity Error 3 Log Message The Remote Insight board has been reset Event Identifiers 5632 5684 Event identifier cpqsvmsg dll 5632 Hex 0x8435 1600 Service Event Log Severity Warning 2 Log Message The Rack And Enclosure MIB Agent could not allocate memory The data contains the error code Event identifier cpqsvmsg dll 5633 Hex 0x84351601 Service Event Log Severity Warning 2 Log Message The Rack And Enclosure MIB Agent could not open the base of the registry The data contains the error code Event identifier cpqsvmsg dll 5634 Hex 0x8435 1602 Service Event Log Severity Warning 2 Log Message 1 The data contains the error code Event identifier cpqsvmsg dll 5635 Hex 0x8435 1603 Service Event Server agents 126 Log Severity Warning 2 Log Message 1 The data contains the error code Event identifier cpqsvmsg dll 5636 Hex 0x8435 1604 Service Event Log Severity Warning 2 Log Message The Rack And Enclosure MIB Agent could not read the registry value 1 The data contains the error code Event identifier cpqsvmsg dll 5637 Hex 0x8435 1605 Service Event Log Severity Warning 2 Log Message The Rack And Enclos
131. nvalid configuration Use the HP Insight Management Agents control panel to verify the Asynchronous Management configuration settings Use the Network control panel to verify the Remote Access configuration If this error persists reinstalling the Storage Agents or the Remote Access Service may correct this error For more information see the Insight Asynchronous Management documentation Event identifier cpqstmsg dll 3584 Hex 0x84350e00 Service Event Log Severity Warning 2 Storage agents 78 Log Message The IDE Agent could not allocate memory The data contains the error code Event identifier cpqstmsg dll 3585 Hex 0x84350e01 Service Event Log Severity Warning 2 Log Message The IDE Agent could not open the base of the registry The data contains the error code Event identifier cpqstmsg dll 3586 Hex 0x84350e02 Service Event Log Severity Warning 2 Log Message 1 The data contains the error code Event identifier cpqstmsg dll 3587 Hex 0x84350e03 Service Event Log Severity Warning 2 Log Message 1 The data contains the error code Event identifier cpqstmsg dll 3588 Hex 0x84350e04 Service Event Log Severity Warning 2 Log Message The IDE Agent could not read the registry value 1 The data contains the error code Event identifier cpqstmsg dll 3589 Hex 0x84350e05 Service Event Log Severity Warning 2 Log Message The IDE Agent found an incorrect type for reg
132. og Severity Warning 2 Event Title Drive Array Spare Drive Status Change Log Message The spare drive in 4 port 5 bay 6 has a new status of 2 SNMP Trap cpqDa SpareStatusChange 3035 in CPQIDA MIB Symptom Spare Drive Status Change This trap indicates that the agent has detected a change in the status of a drive array spare drive The variable coqDaSpareStatus indicates the current spare drive status Storage agents 64 User Action If the spare drive status is failed replace the drive Supporting SNMP Trap Data e sysName e cpqHoTrapFlags e cpqDaCntlrHwLocation e cpqDaSpareCntlrindex e cpqDaSparePhyDrvlindex e cpqDaSpareStatus e cpqDaSpareBusNumber e cpqDaSpareBay Supporting SNMP Trap Description Spare Status is now ceqDaSpareStatus NT Event ID 1202 Hex 0x843504b2 cpqstmsg dll Log Severity Warning 2 Event Title Drive Array Physical Drive Status Change Log Message The physical drive in 4 port 5 bay 6 with serial number 7 has a new status of 2 SNMP Trap cpqDa PhyDrvStatusChange 3036 in CPQIDA MIB Symptom Physical Drive Status Change This trap indicates that the agent has detected a change in the status of a drive array physical drive The variable cpaDaPhyDrvStatus indicates the current physical drive status User Action If the physical drive status is failed 3 or predictive Failure 4 replace the drive Supporting SNMP Trap Data e sysName e c
133. olFan ndex NT Event ID 1130 Hex 0xc435046a cpqsvmsg dll Log Severity Error 3 Log Message The Fan Sub system is in a failed state Replace the fan SNMP Trap cpqHe3FltTolFanFailed 6036 in CPQHLTH MIB Symptom The Fault Tolerant Fan condition has been set to failed for the specified chassis and fan Supporting SNMP Trap Data e sysName e cpqHoTrapFlags e cpqHeFltTolFanChassis e cpqHeFltTolFanlndex Supporting SNMP Trap Description The Fan Failed on Chassis cpqHeFltTolFanChassis Fan cpqHeFltTolFanIndex NT Event ID 1131 Hex 0x8435046b cpqsvmsg dll Log Severity Warning 2 Log Message The Fan Sub system has lost redundancy Replace any failed or missing fans SNMP Trap cpqHe3FitTolFanRedundancyLost 6037 in CPQHLTH MIB Symptom The Fault Tolerant Fans have lost redundancy for the specified chassis Server agents 99 Supporting SNMP Trap Data e sysName e cpqHoTrapFlags e cpqHeFltTolFanChassis Supporting SNMP Trap Description The Fans are no longer redundant on Chassis cpqHeFltTolFanChassis NT Event ID 1132 Hex 0x4435046c cpqsvmsg dll Log Severity Information 1 Log Message Fan Inserted A hot plug fan has been inserted into the system SNMP Trap cpqHe3FltTolFanInserted 6038 in CPQHLTH MIB Symptom A Fault Tolerant Fan has been inserted into the specified chassis and fan location Supporting SNMP Trap Data e sysName e cpqHoTrapFlags cpq
134. ould not set the service status with the Service Control Manager The data contains the error code Event identifier cpqsvmsg dll 260 Hex 0x84350104 Service Event Log Severity Warning 2 Log Message The Server Agents service could not create an event object The data contains the error code Event identifier cpqsvmsg dll 261 Hex 0x84350105 Service Event Log Severity Warning 2 Log Message The Server Agents service could not open registry key 1 The data contains the error code Event identifier coqsvmsg dll 262 Hex 0x84350106 Service Event Log Severity Warning 2 Log Message The Server Agents service could not start any agents successfully Event identifier coqsvmsg dll 263 Hex 0x84350107 Service Event Log Severity Warning 2 Log Message The Server Agents service could not read the registry value 1 The data contains the error code Event identifier cpqsvmsg dll 264 Hex 0x84350108 Service Event Server agents 82 Log Severity Warning 2 Log Message The Server Agents service could not load the module 1 The data contains the error code Event identifier coqsvmsg dll 265 Hex 0x84350109 Service Event Log Severity Warning 2 Log Message The Server Agents service could not get the control function for module 1 The data contains the error code Event identifier coqsvmsg dll 266 Hex 0x8435010a Service Event Log Severity Warning 2 Log Me
135. ower on via manual override on blade cpqRackServerBladePosition in enclosure cpqRackServerBladeEnclosureName in rack cpqRackName NT Event ID 1169 Hex 0x84350491 cpqsvmsg dll Log Severity Warning 2 Event Title Fuse or Breaker Tripped Log Message The fuse has been tripped SNMP Trap cpqRackFuseOpen 22027 in CPQRACK MIB Symptom Fuse open The fuse has been tripped User Action Check enclosure and blade power connections and reset the fuse Supporting SNMP Trap Data e sysName e cpqHoTrapFlags e cpqRackName e cpqRackUid e cpqRackCommonEnclosureName e cpqRackCommonEnclosureFuseLocation cpgRackCommonEnclosureSparePartNumber Server agents 117 e cpgRackCommonEnclosureSerialNum e cpgRackCommonEnclosureTrapSequenceNum Supporting SNMP Trap Description Fuse open fuse cpqRackCommonEnclosureFuseLocation in enclosure cpqRackCommonEnclosureName in rack cpqRackName NT Event ID 1170 Hex 0x84350492 cpqsvmsg dll Log Severity Warning 2 Event Title Server Blade Removed Log Message The server blade has been removed from the enclosure SNMP Trap cpqRackServerBladeRemoved 22028 in CPQRACK MIB Symptom Server blade removed The server blade has been removed from the enclosure User Action None Supporting SNMP Trap Data e sysName e cpqHoTrapFlags e cpqRackName e cpqRackUid e cpqRackServerBladeEnclosureName e cpqRackServerBladeName e cpq
136. pporting SNMP Trap Description Status is now cpqFcaCntlrStatus NT Event ID 1152 Hex 0x84350480 cpqstmsg dll Log Severity Warning 2 Event Title Storage System Fan Module Status Change Log Message Storage system 4 fan module at location 5 has a new status of 6 SNMP Trap cpqSsEx2FanStatusChange 8020 in CPQSTSYS MIB Symptom Storage system fan status change The agent has detected a change in the fan module status of a storage system The variable cpqSsFanModuleStatus indicates the current fan status User Action If the fan status is degraded or failed replace any failed fans Supporting SNMP Trap Data e sysName Storage agents 45 e cpqHoTrapFlags e cpqSsChassisName e cpqSsChassisTime e cpqSsFanModulelocation e cpqSsFanModuleStatus e cpqSsFanModuleSerialNumber e cpqSsFanModuleBoardRevision Supporting SNMP Trap Description Storage system fan status changed to cpqSsFanModuleStatus NT Event ID 1153 Hex 0x84350481 cpqstmsg dll Log Severity Warning 2 Event Title Storage System Power Supply Status Change Log Message Storage system 4 power supply in bay 5 has a new status of 6 SNMP Trap cpqSsEx2PowerSupplyStatusChange 8021 in CPQSTSYS MIB Symptom Storage system power supply status change The agent has detected a change in the power supply status of a storage system The variable coqSsPowerSupplyStatus indicates the current status User Actio
137. pporting SNMP Trap Description Storage system fan status changed to cpqSsBackplaneFanStatus NT Event ID 1189 Hex 0x843504a5 cpqstmsg dll Log Severity Warning 2 Event Title Storage System Temperature Status Change Log Message An enclosure attached to port 5 of storage system 4 has a new temperature status of 7 The enclosure model is 6 SNMP Trap cpqSsExBackplaneTempStatusChange 8023 in CPQSTSYS MIB Symptom Storage System Temperature Status Change The agent has detected a change in the status of the temperature in a storage system The variable coqSsBackplaneTempStatus indicates the current status User Action If the temperature status is degraded or failed shut down the storage system as soon as possible Be sure that the storage system environment is being cooled properly and that no components are overheated Supporting SNMP Trap Data e sysName e cpqHoTrapFlags e cpqSsChassisName e cpqSsChassisTime e cpqSsBackplanelndex e cpqSsBackplaneVendor e cpqSsBackplaneModel e cpqSsBackplaneSerialNumber e cpqSsBackplaneTempStatus Storage agents 58 Supporting SNMP Trap Description Storage system temperature status changed to cpqSsBackplaneTempStatus NT Event ID 1190 Hex 0x843504a6 cpqstmsg dll Log Severity Warning 2 Event Title Storage System Power Supply Status Change Log Message An enclosure attached to port 5 of storage system 4 ha
138. pqHoTrapFlags e cpqDaCntlrHwLocation e cpqDaPhyDrvCntlrindex e cpqDaPhyDrvindex e cpqDaPhyDrvBusNumber e cpqDaPhyDrvBay e cpqDaPhyDrvModel e cpqDaPhyDryFWRev e cpqDaPhyDrvSerialNum e cpqDaPhyDrvFailureCode e cpqDaPhyDrvStatus Supporting SNMP Trap Description Physical Drive Status is now cpqDaPhyDrvStatus NT Event ID 1203 Hex 0x843504b3 cpqstmsg dll Log Severity Warning 2 Event Title Drive Array Physical Drive Threshold Exceeded Log Message The physical drive in 4 port 5 bay 6 with serial number 7 has exceeded a drive threshold Storage agents 65 SNMP Trap cpqDa PhyDrvThreshPassedTrap 3037 in CPQIDA MIB Symptom Physical Drive Threshold Passed This trap indicates that the agent has detected a factory threshold associated with one of the physical drive objects on a drive array has been exceeded User Action Replace the physical drive Supporting SNMP Trap Data e sysName e cpqHoTrapFlags e cpqDaCntlrHwLocation e cpqDaPhyDrvCntlrindex e cpqDaPhyDrvindex e cpq DaPhyDrvBusNumber e cpqDaPhyDrvBay e cpqDaPhyDrvModel e cpqDaPhyDrvFWRev e cpqDaPhyDrvSerialNum Supporting SNMP Trap Description Factory threshold passed for a physical drive NT Event ID 1204 Hex 0x843504b4 cpqstmsg dll Log Severity Warning 2 Event Title Drive Array Accelerator Status Change Log Message The array accelerator board attached to the array controller in
139. r Windows Each event entry has the corresponding SNMP trap number used by the agents Other information on the events in this document includes Event Severity Event Message Event Message Source Event Symptom and Supporting SNMP Trap Data Windows NT event log format The following pages contain HP Insight Management events that are entered into the Microsoft Windows NT Event Log when they occur Values are 32 bit values laid out as follows 3322222222221111111111 10987654321098765432109876543210 a Sev C R Facility Code a where Sev The severity code 00 Success 01 lInformational 10 Warning 11 Error C The customer code flag R A reserved bit Facility The facility code always CPQ Code The facility s status code the event number the upper byte refers to the HP Insight Management Agent that served the event the lower byte is the actual event number a descriptions Foundation Host Agent cpqhsmsg e Sever Agent cpaqsvmsg e Storage Agent cpastmsg e NIC Agent cpqnimsg Introduction 4 Where to go for additional help In addition to this guide the following information sources are available e User documentation e HP Insight Manager software Telephone numbers For the name of the nearest HP authorized reseller e Inthe United States see the HP US service locator webpage http www hp com service_locator e In other locations see the H
140. r procedure may correct this error Event identifier cpqhsmsg dll 3090 Hex 0x84350c12 Service Event Log Severity Warning 2 Log Message Unable to allocate memory This indicates a low memory condition Rebooting the system will correct this error Event identifier coqhsmsg dll 3840 Hex 0x84350f00 Service Event Log Severity Warning 2 Log Message Unable to allocate memory This indicates a low memory condition Rebooting the system will correct this error Event identifier coqhsmsg dll 3841 Hex 0x84350f01 Service Event Log Severity Warning 2 Log Message Could not read from the registry sub key This error can be caused by a corrupt registry or a low memory condition Rebooting the server may correct this error Event identifier coqhsmsg dll 3842 Hex 0x84350f02 Service Event Log Severity Warning 2 Log Message Could not write the registry sub key 1 This error can be caused by a corrupt registry or a low memory condition Rebooting the server may correct this error Event identifier cpqhsmsg dll 3843 Hex 0x84350f03 Service Event Log Severity Warning 2 Log Message Could not read the registry sub key 1 This error can be caused by a corrupt registry or a low memory condition Rebooting the server may correct this error Event identifier cpoqhsmsg dll 3844 Hex 0x84350f04 Service Event Log Severity Warning 2 Log Message Could not write the registry sub key 1
141. rap Description Status is now cpqFcalogDryStatus NT Event ID 1146 Hex 0xc435047a cpqstmsg dll Log Severity Error 3 Event Title External Array Physical Drive Status Change Log Message The physical drive in port 5 bay 6 on array 4 has a new status of 7 SNMP Trap cpgFca2PhyDrvStatusChange 16016 in CPQFCA MIB Symptom External Array Physical Drive Status Change This trap indicates that the agent has detected a change in the status of a physical drive The variable cpaFcaPhyDrvStatus indicates the current physical drive status User Action If the physical drive status is threshExceeded 4 predictiveFailure 5 or failed 6 replace the drive Supporting SNMP Trap Data e sysName e cpqHoTrapFlags e cpqSsChassisName e cpqSsChassisTime e cpqFcaPhyDrvBusNumber e cpqFcaPhyDrvBay e cpqFcaPhyDrvStatus Storage agents 42 e cpqFcaPhyDrvModel e cpqFcaPhyDrvSerialNum e cpqFcaPhyDrvFWRev e cpqFcaPhyDrvFailureCode Supporting SNMP Trap Description Status is now cpqFcaPhyDrvStatus for a physical drive on bus cpqFcaPhyDrvBusNumber bay cpqFcaPhyDrvBay NT Event ID 1147 Hex 0xc435047b cpqstmsg dlil Log Severity Error 3 Event Title External Array Spare Drive Status Change Log Message The spare drive in port 5 bay 6 on array 4 has a new status of 7 SNMP Trap cpqFcaSpareStatusChange 16002 in CPQFCA MIB Symptom External Array Spare Drive Status
142. rePartNumber e cpqRackCommonEnclosureTrapSequenceNum Server agents 105 Supporting SNMP Trap Description The enclosure cpoqRackCommonEnclosureName has been inserted into rack cpqRackName NT Event ID 1147 Hex 0xc435047b cpqsvmsg dll Log Severity Error 3 Event Title Rack Enclosure Overheated Log Message This trap indicates that an enclosure temperature sensor has been tripped indicating an overheat condition SNMP Trap cpqRackEnclosureTempFailed 22005 in CPQRACK MIB Symptom The enclosure temperature status has been set to failed This trap indicates that an enclosure temperature sensor has been tripped indicating an overheat condition User Action Shut down the enclosure and possibly the rack as soon as possible Be sure that all fans are working properly and that air flow in the rack has not been blocked Supporting SNMP Trap Data e sysName e cpqHoTrapFlags e cpqRackName e cpqRackUid e cpqRackCommonEnclosureName e cpqRackCommonEnclosureSerialNum e cpqRackCommonEnclosureTempLocation e cpqRackCommonEnclosureSparePartNumber e cpqRackCommonEnclosureTrapSequenceNum Supporting SNMP Trap Description The enclosure cpqRackCommonEnclosureName temperature sensor in rack cpqRackName has been set to failed NT Event ID 1148 Hex 0x8435047c cpqsvmsg dll Log Severity Warning 2 Event Title Rack Enclosure Overheating Log Message This trap indicates that an e
143. rning 2 Log Message The External Status MIB Agent could not set the variable because it is unsupported The data contains the error code Event identifier cpqhsmsg dll 4406 Hex 0x84351136 Service Event Log Severity Warning 2 Log Message The External Status MIB Agent could not set the variable because the value is invalid or out of range The data contains the error code Foundation agents 26 Event identifier cpoqhsmsg dll 4407 Hex 0x84351137 Service Event Log Severity Warning 2 Log Message The External Status MIB Agent is not loaded Sets are not available The data contains the error code Event identifier coqhsmsg dll 4608 Hex 0x84351200 Service Event Log Severity Warning 2 Log Message Unable to allocate memory This indicates a low memory condition Rebooting the system will correct this error Event identifier coqhsmsg dll 4609 Hex 0x84351201 Service Event Log Severity Warning 2 Log Message Could not read from the registry sub key This error can be caused by a corrupt registry or a low memory condition Rebooting the server may correct this error Event identifier cpoqhsmsg dll 4610 Hex 0x84351202 Service Event Log Severity Warning 2 Log Message Could not write the registry sub key 1 This error can be caused by a corrupt registry or a low memory condition Rebooting the server may correct this error Event identifier cpqhsmsg dll 4611 Hex 0x84351203 Servic
144. rning 2 Log Message The Threshold Agent could not set the variable because it is unsupported The data contains the error code Event identifier coqhsmsg dll 2358 Hex 0x84350936 Service Event Log Severity Warning 2 Foundation agents 20 Log Message The Threshold Agent could not set the variable because the value is invalid or out of range The data contains the error code Event identifier cpqhsmsg dll 2359 Hex 0x84350937 Service Event Log Severity Warning 2 Log Message The Threshold Agent is not loaded Sets are not available The data contains the error code Event Identifiers 3072 3876 Event identifier cpqhsmsg dll 3072 Hex 0x84350c00 Service Event Log Severity Warning 2 Log Message Could not read from the registry sub key This error can be caused by a corrupt registry or a low memory condition Rebooting the server may correct this error Event identifier cpqhsmsg dll 3073 Hex 0x84350c01 Service Event Log Severity Warning 2 Log Message Could not create the registry sub key 1 This error can be caused by a corrupt registry or a low memory condition Rebooting the server may correct this error Event identifier coqhsmsg dll 3074 Hex 0x84350c02 Service Event Log Severity Warning 2 Log Message Could not create the registry sub key 1 This error can be caused by a corrupt registry or a low memory condition Rebooting the server may correct this error Event
145. rror code while waiting for an event The data contains the error code Event identifier cpqhsmsg dll 2315 Hex 0x8435090b Service Event Log Severity Warning 2 Log Message The Threshold Agent did not respond to a request The data contains the error code Event identifier coqhsmsg dll 2316 Hex 0x8435090c Service Event Log Severity Warning 2 Log Message The Threshold Agent received an unknown action code from the service The data contains the action code Event identifier coqhsmsg dll 2317 Hex 0x8435090d Service Event Log Severity Warning 2 Log Message The Threshold Agent could not get the system type The data contains the error code Event identifier coqhsmsg dll 2354 Hex 0x84350932 Service Event Log Severity Warning 2 Log Message The Threshold Agent could not create an SNMP session The data contains the error code Event identifier coqhsmsg dll 2355 Hex 0x84350933 Service Event Log Severity Warning 2 Log Message The Threshold Agent SNMP request failed The data contains the error code Action 1 Be sure that the SNMP service is configured to allow SNMP requests from localhost 2 Be sure that there is an adequate amount of free memory Event identifier coqhsmsg dll 2356 Hex 0x84350934 Service Event Log Severity Warning 2 Log Message 1 The data contains the error code Event identifier coqhsmsg dll 2357 Hex 0x84350935 Service Event Log Severity Wa
146. rs NT Event ID 1111 Hex 0xc4350457 cpqsvmsg dll Log Severity Error 3 Log Message The Remote Insight Board has detected a controller interface error SNMP Trap cpqSm2InterfaceError 9006 in CPQSM2 MIB Symptom Remote Insight Integrated Lights Out Interface Error The host OS has detected an error in the Remote Insight Integrated Lights Out interface The firmware is not responding Supporting SNMP Trap Data e sysName e cpqHoTrapFlags Supporting SNMP Trap Description Server sysName Remote Insight Integrated Lights Out interface error NT Event ID 1112 Hex 0x84350458 cpqsvmsg dll Log Severity Warning 2 Log Message The Remote Insight Board has detected that the battery is disconnected SNMP Trap cpqSm2BatteryDisconnected 9007 in CPQSM2 MIB Symptom Remote Insight Battery Disconnected The Remote Insight battery cable has been disconnected Supporting SNMP Trap Data e sysName e cpqHoTrapFlags Supporting SNMP Trap Description Remote Insight battery disconnected NT Event ID 1113 Hex 0x84350459 cpqsvmsg dll Log Severity Warning 2 Log Message The Remote Insight Board has detected that the keyboard cable is disconnected SNMP Trap cpqSm2KeyboardCableDisconnected 9008 in CPQSM2 MIB Symptom Keyboard Cable Disconnected The Remote Insight keyboard cable has been disconnected Supporting SNMP Trap Data e sysName Server agents 94 e cpqHoTrapFlags Suppo
147. rsists reinstalling the Management Agents may correct this error Event identifier coqhsmsg dll 1808 Hex 0x44350710 Service Event Log Severity Information 1 Log Message The agent could not deliver trap 1 The agent was unable to use Asynchronous Management to deliver a trap This can be caused by a failure in the Remote Access Service or by a missing or invalid configuration Use the Management Agents control panel to verify the Asynchronous Management configuration settings Use the Network control panel to verify the Remote Access configuration If this error persists reinstalling the Management Agents or the Remote Access Service may correct this error For more information see the Management Agents Asynchronous Management documentation Event Identifiers 2048 2359 Event identifier coqhsmsg dll 2048 Hex 0x84350800 Service Event Foundation agents 17 Log Severity Warning 2 Log Message Unable to allocate memory This indicates a low memory condition Rebooting the system will correct this error Event identifier coqhsmsg dll 2049 Hex 0x84350801 Service Event Log Severity Warning 2 Log Message Unable to read from the registry This error can be caused by a corrupt registry or a low memory condition Rebooting the server may correct this error Event identifier cpqhsmsg dll 2050 Hex 0x84350802 Service Event Log Severity Warning 2 Log Message Could not create the registry sub key 1 T
148. rting SNMP Trap Description Remote Insight keyboard cable disconnected NT Event ID 1114 Hex 0x8435045a cpqsvmsg dll Log Severity Warning 2 Log Message A processor has crossed the threshold of allowable corrected errors The processor should be replaced SNMP Trap cpqSeCpuThresholdPassed 1001 in CPQSTDEQ MIB Symptom This trap is sent when an internal processor error threshold has been passed on a particular processor causing it to become degraded This trap is sent when cpqSeCpuThreshPassed transitions from false to true Supporting SNMP Trap Data e sysName e cpqHoTrapFlags e cpqSeCpuSlot e cpqSeCpuSocketNumber Supporting SNMP Trap Description CPU internal corrected errors have passed a set threshold NT Event ID 1115 Hex 0x8435045b cpqsvmsg dll Log Severity Warning 2 Log Message A computer cover has been removed since last system start up Be sure the system cover is installed properly This situation may result in improper cooling of the system due to air flow changes caused by the missing cover SNMP Trap cpqSiHoodRemoved 2001 in CPQSINFO MIB Symptom The access panel is removed The access panel status has been set to removed The access panel is not installed properly This situation may result in improper cooling of the system due to air flow changes caused by the missing access panel User Action Replace the access panel and be sure that it is installed properly Verify that
149. rupt registry or a low memory condition Rebooting the server may correct this error Event identifier cpqnimsg dll 269 Hex 0xc435010d Service Event Log Severity Error 3 Log Message The NIC Management Agent encountered a fatal error The service is terminating The data contain the error code Event identifier coqnimsg dll 270 Hex 0x8435010e Service Event Log Severity Warning 2 Log Message Unable to create thread This error can be caused by a low memory condition Rebooting the server may correct this error Event identifier cpqnimsg dll 271 Hex 0x8435010f Service Event Log Severity Warning 2 Log Message Could not open the driver for device 1 This error can be caused by an improperly installed adapter Removing and reinstalling the device may correct the problem The data contain the error code Event identifier cpqnimsg dll 272 Hex 0x843501 10 Service Event Log Severity Warning 2 Log Message Failure in driver 1 This error can be caused by an outdated driver version Installing a later version of the driver may correct the problem The data contain the error code Event identifier cpqnimsg dll 273 Hex 0x84350111 Service Event NIC agents 130 Log Severity Warning 2 Log Message There were no physical adapters in team 1 This error can be caused by improperly installed drivers Remove all device instances associated with the team and re install the drivers and team
150. rver Agents service could not write the registry value 1 The data contains the error code Event identifier cpqsvmsg dll 399 Hex 0xc435018f Service Event Server agents 83 Log Severity Error 3 Log Message The Server Agents service encountered a fatal error The service is terminating The data contains the error code Event identifier cpqsvmsg dll 400 Hex 0x44350190 Service Event Log Severity Information 1 Log Message The Server Agents service version 1 has started Event identifier cpqsvmsg dll 401 Hex 0x44350191 Service Event Log Severity Information 1 log Message 1 Event identifier cpoqsvmsg dll 768 Hex 0x84350300 Service Event Log Severity Warning 2 Log Message The Remote Alerter Agent detected an invalid data type within an alert definition Event identifier cpqsvmsg dll 769 Hex 0x84350301 Service Event Log Severity Warning 2 Log Message The Remote Alerter Agent detected an error while attempting to log an alert remotely The data contains the error code Event identifier cpqsvmsg dll 770 Hex 0x84350302 Service Event Log Severity Warning 2 Log Message The Remote Alerter Agent detected an error while attempting to retrieve data from key 1 in the registry The data contains the error code Event identifier cpqsvmsg dll 771 Hex 0x84350303 Service Event Log Severity Warning 2 Log Message The Remote Alerter Agent was unable to log an event in the
151. rver s temperature has returned to its normal operating range SNMP Trap cpqHe3ThermalTempOk 6019 in CPQHLTH MIB Symptom The temperature status has been set to OK The server s temperature has returned to the normal operating range Supporting SNMP Trap Data e sysName e cpqHoTrapFlags Supporting SNMP Trap Description Temperature has returned to normal range NT Event ID 1085 Hex 0xc435043d cpqsvmsg dll Log Severity Error 3 Log Message A System Fan Condition has been set to failed The system may be shut down due to this thermal condition SNMP Trap cpqHe3ThermalSystemFanFailed 6020 in CPQHLTH MIB Symptom The system fan status has been set to failed A required system fan is not operating normally The system is shut down if the coqHeThermalDegradedAction variable is set to shutdown 3 Supporting SNMP Trap Data e sysName e cpqHoTrapFlags e cpqHeThermalDegradedAction Supporting SNMP Trap Description Required fan not operating normally Shutdown may occur Server agents 90 NT Event ID 1086 Hex 0x8435043e cpqsvmsg dll Log Severity Warning 2 Log Message A System Fan Condition has been set to degraded If the system fan is part of a redundancy group the system will not be shut down If the system fan is not part of a redundancy group the system may be shut down depending on the state of the thermal degraded action value A SNMP Trap cpqHe3ThermalSystemFanDegraded 6
152. rverPowerOnFailedPowerChassisNotFound 22025 in CPQRACK MIB Symptom Inadequate power to power on There is not enough power to power on the server blade The power enclosure micro controller was not found User Action Check power enclosure connections or add power supplies Supporting SNMP Trap Data e sysName e cpqHoTrapFlags e cpqRackName e cpqRackUid e cpqRackServerBladeEnclosureName e cpqRackServerBladePosition e cpqRackServerBladeSparePartNumber e cpqRackCommonEnclosureSerialNum Server agents 116 e cpgRackCommonEnclosureTrapSequenceNum Supporting SNMP Trap Description Inadequate power to power on blade cpqRackServerBladePosition in enclosure cpqRackServerBladeEnclosureNamel in rack cpqRackName NT Event ID 1168 Hex 0x84350490 cpqsvmsg dll Log Severity Warning 2 Event Title Server Power On Via Manual Override Log Message Server power on via manual override SNMP Trap cpqRackServerPowerOnManualOverride 22026 in CPQRACK MIB Symptom Server power on via manual override The server blade was powered on by a manual override User Action None Supporting SNMP Trap Data e sysName e cpqHoTrapFlags e cpqRackName e cpqRackUid e cpqRackServerBladeEnclosureName e cpqRackServerBladePosition e cpqRackServerBladeSparePartNumber e cpqRackCommonEnclosureSerialNum e cpqRackCommonEnclosureTrapSequenceNum Supporting SNMP Trap Description Server p
153. rvice may not have started or may still be in the starting state Event identifier coqhsmsg dll 4626 Hex 0x84351212 Service Event Log Severity Warning 2 Log Message The Agent failed to process the MOF file to get the data from WMI Problem with WMI service or MOF file or wrong file paths used Foundation agents 28 Storage agents Event Identifiers 256 774 Event identifier cpqstmsg dll 256 Hex 0x84350100 Service Event Log Severity Warning 2 Log Message The Storage Agents service detected an error The insertion string is 1 The data contains the error code Event identifier cpqstmsg dll 257 Hex 0x84350101 Service Event Log Severity Warning 2 Log Message The Storage Agents service could not allocate memory The data contains the error code Event identifier cpqstmsg dll 258 Hex 0x84350102 Service Event Log Severity Warning 2 Log Message The Storage Agents service could not register with the Service Control Manager The data contains the error code Event identifier cpqstmsg dll 259 Hex 0x84350103 Service Event Log Severity Warning 2 Log Message The Storage Agents service could not set the service status with the Service Control Manager The data contains the error code Event identifier cpqstmsg dll 260 Hex 0x84350104 Service Event Log Severity Warning 2 Log Message The Storage Agents service could not create an event object The data contains the error code
154. s a new power supply status of 7 The enclosure model is 6 SNMP Trap cpqSsExBackplanePowerSupplyStatusChange 8024 in CPQSTSYS MIB Symptom Storage System Power Supply Status Change The agent has detected a change in the power supply status of a storage system The variable cpqSsBackplaneFtpsStatus indicates the current status User Action If the power supply status is degraded restore power or replace the failed power supply Supporting SNMP Trap Data e sysName e cpqHoTrapFlags e cpqSsChassisName e cpqSsChassisTime e cpqSsBackplanelndex e cpqSsBackplaneVendor e cpqSsBackplaneModel e cpqSsBackplaneSerialNumber e cpqSsBackplaneFtpsStatus Supporting SNMP Trap Description Storage system power supply status changed to cpqSsBackplaneFtpsStatus NT Event ID 1191 Hex 0x843504a7 cpqstmsg dll Log Severity Warning 2 Event Title SCSI Tape Library Status Change Log Message The tape library with SCSI target 6 connected to SCSI bus 5 of the controller in slot 4 has a new status of 7 SNMP Trap cpqTapelibraryStatusChange 5018 in CPQSCSI MIB Symptom Tape Library Status Change The Storage Agent has detected a change in the status of a tape library The current tape library status is indicated in the cpqTapeLibraryState variable Supporting SNMP Trap Data e sysName e cpqHoTrapFlags e cpq apelLibraryCntlrindex e cpqTapeLibraryBusIndex e cpq apelibraryScsil
155. sestamsiyna Vomaantatanasenedigouantaltondnetqibtedantseaniwieda a mivenngendati tenn 5 Telephone MUMOSIS aiseee mo e eea EnA A EEEE A E E EAA REEE EE EDRI eae 5 Pa R E E E T N le Onc C Tea MS ert nnn torte etree 6 Event Identifiers 256 774 ccccccccccccccccccccceecceescsescesscessesssesssessesssssteesteesseesseeteeesseeseesseeteeseseeseeeseeeeees 6 Event Identifiers 1105 1808 cicccccccccccccccceesceecseecesestes sess 1 e esters seesstesstesstessteeseesseeeeeeseeeseeeeees 9 Event Identifiers 2048 2359 o oo cece cece ccccccccccceecccseeeececseceecesseseseseseceeeeeseeeseeeseeeseeeseeeseseseceseceeeeeegs 17 Event Identifiers 3072 387 Giscieccocicacevds seseecesacseenssencdvecosdegdavsis ae i E EE ERTE EEN E ETENEE 21 Event Identifiers 4352 4626 cccccccccccccccccccccscccsccesceeeecessceeecesseueecessseeseseeseeeseesaseseseteeeseseseeeseseseeeseeeeeeeess 25 CHONG GS Werna a ates aadeusausiteceutosaasionsennees 29 Event Identifiers 256 774 usssussensriusiinirikiiitrirt iit rrt 11e 11r 11e 11 S1 eS P S A S P S L S P S L SSP SSP SSP EPEE PEE EEE EEEEEE 29 Event Identifiers 1061 1098 sssesseusssinnrensrinriiriii iiit kitt irt tit rit r te re ere i S L eSP SSP SSP SSE SSP SSE EPEE EEEEEEEEEE 32 Event Identitiers 1012 199 ioc cocicasesdsscseecesadgeaessoncscaresdegdasss esunccsedideetesssgedcdseedeeetvyssseusevedseisieasencotacsesns say 38 Event Identifiers 1200 1294 cccccccccccccccccccccccceccccscceeecesscesscesseeeec
156. ssage The NIC Agent service could not terminate agent 1 The data contain the error code Event identifier cpqnimsg dll 294 Hex 0x84350126 Service Event Log Severity Warning 2 Log Message The NIC Agent service could not unload the module 1 The data contain the error code Event identifier cpqnimsg dll 296 Hex 0xc4350128 Service Event Log Severity Error 3 Log Message A driver for a NIC failed to open This error can be caused by an improperly installed adapter Removing and reinstalling all adapters may correct the problem The NIC Agent service will not respond to any management requests Event identifier cpqnimsg dll 297 Hex 0x84350129 Service Event Log Severity Warning 2 Log Message An attempt to log an event to the IML failed The IML log may be full Clearing the IML log may correct this problem Event identifier cpqnimsg dll 298 Hex 0xc435012a Service Event Log Severity Error 3 Log Message A fatal error occurred during Virus Throttle WMI event processing Virus Throttle related traps will not be sent NIC agents 132 Cause WMI service is probably not running Starting WMI service or NIC agent might solve this problem Event identifier cpqnimsg dll 299 Hex 0x8435012b Service Event Log Severity Warning 2 Log Message An attempt to query WMI for Virus Throttle event failed The event data gives the error number Event Identifiers 300 1293 Event identifier
157. ssage The Server Agents service could not initialize agent 1 The data contains the error code Event identifier cpqsvmsg dll 267 Hex 0x8435010b Service Event Log Severity Warning 2 Log Message The Server Agents service could not start agent 1 The data contains the error code Event identifier cpqsvmsg dll 268 Hex 0x8435010c Service Event Log Severity Warning 2 Log Message The Server Agents service detected an invalid state for agent 1 The data contains the state Event identifier cpqsvmsg dll 269 Hex 0x8435010d Service Event Log Severity Warning 2 Log Message The Server Agents service could not stop agent 1 The data contains the error code Event identifier cpqsvmsg dll 270 Hex 0x8435010e Service Event Log Severity Warning 2 Log Message The Server Agents service could not terminate agent 1 The data contains the error code Event identifier cpqsvmsg dll 271 Hex 0x8435010f Service Event Log Severity Warning 2 Log Message The Server Agents service could not unload the module 1 The data contains the error code Event identifier coqsvmsg dll 272 Hex 0x84350110 Service Event Log Severity Warning 2 Log Message The Server Agents service could not create the registry key 1 The data contains the error code Event identifier cpqsvmsg dll 273 Hex 0x84350111 Service Event Log Severity Warning 2 Log Message The Se
158. ssage The agent is unable to generate traps due to an error during initialization Event identifier coqhsmsg dll 1795 Hex 0x84350703 Service Event Log Severity Warning 2 Log Message The agent is older than other components The agent is older than the other components of the Management Agents Reinstall all of the Management Agents to correct this error Event identifier coqhsmsg dll 1796 Hex 0x84350704 Service Event Log Severity Warning 2 Log Message The 1 Agent is older than other components The 1 Agent is older than the other components of the Management Agents Reinstall all of the Management Agents to correct this error Event identifier coqhsmsg dll 1800 Hex 0x84350708 Service Event Log Severity Warning 2 Log Message Unable to read security configuration information SNMP sets have been disabled Event identifier cpqhsmsg dll 1803 Hex 0xc435070b Service Event Log Severity Error 3 Log Message Unable to load a required library This error can be caused by a corrupt or missing file Reinstalling the Management Agents or running the Emergency Repair procedure may correct this error Event identifier coqhsmsg dll 1806 Hex 0x8435070e Service Event Log Severity Warning 2 Log Message The Foundation SNMP Agent service is not running The agent has determined that the Foundation Agents service is not running Stop the SNMP service and restart the Foundation Agents service If the error pe
159. ssed SNMP Trap cpqMeCriticalFallingAlarmExtended 10008 in CPQTHRSH MIB Symptom Critical Falling Threshold passed An alarm entry has crossed its critical falling threshold The instances of those objects contained within the variable list are those of the alarm entry that generated this trap Supporting SNMP Trap Data e sysName e cpqHoTrapFlags e cpqMeAlarmVariable e cpqMeAlarmSampleType e cpqMeAlarmValue e cpqMeAlarmFallingThreshold e cpqMeAlarmOwner e cpqMeAlarmSeverity e cpqMeAlarmExtendedDescription Supporting SNMP Trap Description ceqMeAlarmOwner Variable cpqMeAlarmVariable has value cpqMeAlarmValue lt cpqMeAlarmFallingThreshold NT Event ID 1166 Hex 0x8435048e cpqhsmsg dll Log Severity Warning 2 log Message 1 SNMP Trap ceqHoProcessEventTrap 11011 in CPQHOST MIB Symptom A monitored process has either started or stopped running Supporting SNMP Trap Data e sysName e cpqHoTrapFlags e cpqHoSwRunningTrapDesc Supporting SNMP Trap Description ceqHdoSwRunningTrapDesc NT Event ID 1167 Hex 0x8435048f cpqhsmsg dll Log Severity Warning 2 Log Message The cluster resource 4 has become degraded SNMP Trap cpqClusterResourceDegraded 15005 in CPQCLUS MIB Foundation agents 11 Symptom This trap is sent any time the condition of a cluster resource becomes degraded User Action Make a note of the cluster resource name and
160. stmsg dll 517 Hex 0x84350205 Service Event Log Severity Warning 2 Log Message Could not read the registry subkey 1 This error can be caused by a corrupt registry or a low memory condition Rebooting the server may correct this error Event identifier cpqstmsg dll 526 Hex 0x8435020e Service Event Log Severity Warning 2 Log Message Unsupported storage system The ProLiant storage system 1 is not supported by this version of the Storage Agents Upgrade the agents to the latest version Event identifier cpqstmsg dll 527 Hex 0x8435020f Service Event Log Severity Warning 2 Storage agents 31 Log Message The Drive Array Agent storage system table is full Event identifier cpqstmsg dll 574 Hex 0x8435023e Service Event Log Severity Warning 2 Log Message The Drive Array Agent failed to get capacity on SCSI drive because SCSI pass through IOCTL failed Event identifier cpqstmsg dll 768 Hex 0x84350300 Service Event Log Severity Warning 2 Log Message The Remote Alerter Agent detected an invalid data type within an alert definition Event identifier cpqstmsg dll 769 Hex 0x84350301 Service Event Log Severity Warning 2 Log Message The Remote Alerter Agent detected an error while attempting to log an alert remotely The data contains the error code Event identifier cpqstmsg dll 771 Hex 0x84350303 Service Event Log Severity Warning 2 Log Message The Remote Alerter Ag
161. te Alerter detected an error while attempting to retrieve data from key 1 in the registry The data contains the error code Event identifier cpqhsmsg dll 771 Hex 0x84350303 Service Event Log Severity Warning 2 Log Message The Host Remote Alerter was unable to log an event in the event log of the system named 1 The data contains the error code Event identifier cpqhsmsg dll 772 Hex 0xc4350304 Service Event Log Severity Error 3 Log Message The Host Remote Alerter detected a null handle on initialization The data contains the error code Event identifier cpqhsmsg dll 773 Hex 0xc4350305 Service Event Log Severity Error 3 Foundation agents 8 Log Message The Host Remote Alerter received an error on WaitForMultipleObjects call The data contains the error code Event identifier cpqhsmsg dll 774 Hex 0xc4350306 Service Event Log Severity Error 3 Log Message The Host Remote Alerter received an error on ResetEvent call The data contains the error code Event Identifiers 1105 1808 NT Event ID 1105 Hex 0x44350451 cpqhsmsg dll Log Severity Information 1 log Message 1 SNMP Trap cpeqHo2GenericTrap 11003 in CPQHOST MIB Symptom Generic trap Supporting SNMP Trap Data e sysName e cpqHoTrapFlags e cpq HoGenericData Supporting SNMP Trap Description cpqHoGenericData NT Event ID 1106 Hex 0x44350452 cpqhsmsg dll Log Severity Information 1 Log Message
162. the system after installing agents Event identifier cpqstmsg dll 1346 Hex 0x84350540 Service Event Log Severity Warning 2 Log Message The SCSI controller on port 1 has been omitted The SCSI Agent could not get the slot data for the controller Event identifier cpqstmsg dll 1792 Hex 0x84350700 Service Event Log Severity Warning 2 Log Message The SNMP Agent is unable to generate traps due to an error during initialization Cause Check to Be sure that the SNMP service is running Reinstalling the agents may fix this error Event identifier cpqstmsg dll 1795 Hex 0x84350703 Service Event Log Severity Warning 2 Storage agents 77 Log Message The SNMP Agent is older than other components The SNMP Agent is older than the other components of the Storage Agents Reinstall the entire Storage Agents package to correct this error Event identifier cpqstmsg dll 1796 Hex 0x84350704 Service Event Log Severity Warning 2 Log Message The 1 Agent is older than other components The 1 Agent is older than the other components of the Storage Agents Reinstall the entire Storage Agents package to correct this error Event identifier cpqstmsg dll 1800 Hex 0x84350708 Service Event Log Severity Warning 2 Log Message Unable to read security configuration information SNMP sets have been disabled Cause This can be cause by an invalid or missing configuration or by a corrupt registry Reinstalling the
163. then check the resource for the cause of the degraded condition Supporting SNMP Trap Data e sysName e cpqHoTrapFlags e cpqClusterResourceName Supporting SNMP Trap Description Cluster resource cpqClusterResourceName has become degraded NT Event ID 1168 Hex 0xc4350490 cpqhsmsg dll Log Severity Error 3 Log Message The cluster resource 4 has failed SNMP Trap cpqClusterResourceFailed 15006 in CPQCLUS MIB Symptom This trap is sent any time the condition of a cluster resource has failed User Action Make a note of the cluster resource name and then check the resource for the cause of the failure Supporting SNMP Trap Data e sysName e cpqHoTrapFlags e cpqClusterResourceName Supporting SNMP Trap Description Cluster resource cpqClusterResourceName has failed NT Event ID 1169 Hex 0x84350491 cpghsmsg dil Log Severity Warning 2 Log Message The cluster network 4 has become degraded SNMP Trap cpqClusterNetworkDegraded 15007 in CPQCLUS MIB Symptom This trap is sent any time the condition of a cluster network becomes degraded User Action Make a note of the cluster network name and then check the network for the cause of the degraded condition Supporting SNMP Trap Data e sysName e cpqHoTrapFlags e cpqClusterNetworkName Supporting SNMP Trap Description Cluster network cpqClusterNetworkName has become degraded NT Event ID 1170 Hex 0xc4350492
164. tle SCSI Logical Drive Status Change Log Message The SCSI logical drive with SCSI target 6 connected to SCSI bus 5 of the controller in slot 4 SCSI has a new status of 2 SNMP Trap cpqScsi3lLogDrvStatusChange 5021 in CPQSCSI MIB Symptom Logical Drive Statues Change The Storage Agent has detected a change in the status of a SCSI logical drive The current logical drive status is indicated in the cpqScsilogDrvStatus variable Supporting SNMP Trap Data e sysName e cpqHoTrapFlags e cpqScsilogDrvStatus e cpqScsiLogDrvCntlrindex e cpqScsiLogDrvBuslndex e cpgqScsiLogDrvindex e cpqScsiLogDrvOsName Supporting SNMP Trap Description Status is now cpqScsiLogDrvStatus NT Event ID 1070 Hex 0xc435042e cpqstmsg dll Log Severity Error 3 Event Title SCSI Physical Drive Status Change Log Message The SCSI physical drive with SCSI target 6 connected to SCSI bus 5 of the controller in slot 4 has a new status of 2 SNMP Trap cpqScsi5PhyDrvStatusChange 5020 in CPQSCSI MIB Symptom Physical Drive Status Change The Storage Agent has detected a change in the status of a SCSI physical drive The current physical drive status is indicated in the cpqScsiPhyDrvStatus variable Supporting SNMP Trap Data Storage agents 36 e sysName e cpqHoTrapFlags e cpqScsiPhyDrvStatus e cpqScsiPhyDrvCntlrindex e cpqScsiPhyDrvBuslndex e cpqScsiPhyDrvindex e cpqScsiPhyDrvVendor e cpq
165. trap indicates that the agent has detected a change in the status of a drive array physical drive The variable cpqDaPhyDrvStatus indicates the current physical drive status User Action If the physical drive status is failed 3 or predictiveFailure 4 replace the drive Supporting SNMP Trap Data e sysName e cpqHoTrapFlags e cpqDaCntlrHwLocation e cpqDaPhyDrvCntlrindex e cpqDaPhyDrvindex e cpqDaPhyDrvLocationString e cpqDaPhyDrvType e cpqDaPhyDrvModel e cpqDaPhyDryFWRev e cpqDaPhyDrvSerialNum e cpqDaPhyDrvFailureCode e cpqDaPhyDrvStatus e cpqDaPhyDrvBusNumber Supporting SNMP Trap Description Physical Drive Status is now cpqDaPhyDrvStatus NT Event ID 1217 Hex 0x843504c1 cpqstmsg dll Log Severity Warning 2 Event Title Drive Array Spare Drive Status Change Log Message The spare drive in 4 5 has a new status of 2 SNMP Trap cpqDa7SpareStatusChange 3047 in CPQIDA MIB Symptom Spare Drive Status Change This trap indicates that the agent has detected a change in the status of a drive array spare drive The variable cpqDaSpareStatus indicates the current spare drive status User Action If the spare drive status is failed replace the drive Supporting SNMP Trap Data e sysName e cpqHoTrapFlags e cpqDaCntlrHwLocation e cpqDaSpareCntlrindex e cpqDaSparePhyDrvlindex e cpqDaSpareStatus e cpqDaSparelocationString e cpqDaSpareDrvBusNumber Supportin
166. tus Change This trap indicates that the agent has detected a change in the status of an array accelerator cache board The current status is represented by the variable cpqDaAccelStatus User Action If the accelerator board status is permDisabled 5 you may need to replace the accelerator board Supporting SNMP Trap Data e sysName e cpqHoTrapFlags e cpqDaCnilrSlot e cpqDaCntlrModel Storage agents 34 e cpqDaAccelSerialNumber e cpqDaAccelTotalMemory e cpqDaAccelStatus e cpqDaAccelErrCode Supporting SNMP Trap Description Status is now cpqDaAccelStatus NT Event ID 1066 Hex 0xc435042a cpqstmsg dll Log Severity Error 3 Event Title Drive Array Accelerator Bad Data Log Message The array accelerator board attached to the array controller in slot 4 is reporting that it contains bad cached data SNMP Trap cpqDa5AccelBadDataTrap 3026 in CPQIDA MIB Symptom Accelerator Board Bad Data This trap indicates that the agent has detected an array accelerator cache board that has lost battery power If data was being stored in the accelerator cache memory when the server lost power that data has been lost User Action Verify that no data has been lost Supporting SNMP Trap Data e sysName e cpqHoTrapFlags e cpqDaCntlrSlot e cpqDaCntlrModel e cpqDaAccelSerialNumber e cpqDaAccelTotalMemory Supporting SNMP Trap Description Accelerator lost battery power Data Loss possible
167. ty Warning 2 Log Message The NIC Management Agent did not respond to a request The data contain the error code Event identifier cpqnimsg dll 285 Hex 0x843501 1d Service Event Log Severity Warning 2 Log Message The NIC Management Agent could not get the system type The data contain the error code Event identifier cpqnimsg dll 287 Hex 0x843501 1f Service Event NIC agents 131 Log Severity Warning 2 Log Message The NIC Agent service could not load the module 1 The data contain the error code Event identifier cpqnimsg dll 288 Hex 0x84350120 Service Event Log Severity Warning 2 Log Message The NIC Agent service could get the control function for module 1 The data contain the error code Event identifier cpqnimsg dll 290 Hex 0x84350122 Service Event Log Severity Warning 2 Log Message The NIC Agent service could not start agent 1 The data contain the error code Event identifier cpqnimsg dll 291 Hex 0x84350123 Service Event Log Severity Warning 2 Log Message The NIC Agent service detected an invalid state for agent 1 The data contain the state Event identifier cpqnimsg dll 292 Hex 0x84350124 Service Event Log Severity Warning 2 Log Message The NIC Agent service could not stop agent 1 The data contain the error code Event identifier cpqnimsg dll 293 Hex 0x84350125 Service Event Log Severity Warning 2 Log Me
168. ubkey 1 This error can be caused by a corrupt registry or a low memory condition Rebooting the server may correct this error Event identifier cpqstmsg dll 4100 Hex 0x8435 1004 Service Event Log Severity Warning 2 Log Message Could not read the registry subkey 1 This error can be caused by a corrupt registry or a low memory condition Rebooting the server may correct this error Event identifier cpqstmsg dll 4101 Hex 0x8435 1005 Service Event Storage agents 80 Log Severity Warning 2 Log Message Could not read the registry subkey 1 This error can be caused by a corrupt registry or a low memory condition Rebooting the server may correct this error Event identifier cpqstmsg dll 4609 Hex 0x84351201 Service Event Log Severity Warning 2 Log Message Could not read the registry subkey This error can be caused by a corrupt registry or a low memory condition Rebooting the server may correct this error Event identifier cpqstmsg dll 4610 Hex 0x8435 1202 Service Event Log Severity Warning 2 Log Message Could not write the registry subkey 1 This error can be caused by a corrupt registry or a low memory condition Rebooting the server may correct this error Event identifier cpqstmsg dll 4611 Hex 0x8435 1203 Service Event Log Severity Warning 2 Log Message Could not read the registry subkey 1 This error can be caused by a corrupt registry or a lo
169. um Supporting SNMP Trap Description Inadequate power to power on blade cpqRackServerBladePosition in enclosure cpqRackServerBladeEnclosureName in rack cpqRackName Server agents 115 NT Event ID 1166 Hex 0xc435048e cpqsvmsg dll Log Severity Error 3 Event Title Inadequate Power To Power On Log Message There is not enough power to power on the server blade The server enclosure micro controller was not found SNMP Trap cpqRackServerPowerOnFailedEnclosureNotFound 22024 in CPQRACK MIB Symptom Inadequate power to power on There is not enough power to power on the server blade The server enclosure micro controller was not found User Action Check server enclosure connections or add power supplies Supporting SNMP Trap Data e sysName e cpqHoTrapFlags e cpqRackName e cpqRackUid e cpqRackServerBladeEnclosureName e cpqRackServerBladePosition e cpqRackServerBladeSparePartNumber e cpqRackCommonEnclosureSerialNum e cpqRackCommonEnclosureTrapSequenceNum Supporting SNMP Trap Description Inadequate power to power on blade cpqRackServerBladePosition in enclosure cpqRackServerBladeEnclosureName in rack cpqRackName NT Event ID 1167 Hex 0xc435048f cpqsvmsg dll Log Severity Error 3 Event Title Inadequate Power To Power On Log Message There is not enough power to power on the server blade The power enclosure micro controller was not found SNMP Trap cpqRackSe
170. ure MIB Agent found an incorrect type for registry value 1 The data contains the type found Event identifier cpqsvmsg dll 5638 Hex 0x8435 1606 Service Event Log Severity Warning 2 Log Message The Rack And Enclosure MIB Agent could not create a necessary event The data contains the error code Event identifier cpqsvmsg dll 5639 Hex 0x8435 1607 Service Event Log Severity Warning 2 Log Message The Rack And Enclosure MIB Agent could not set an event The data contains the error code Event identifier cpqsvmsg dll 5640 Hex 0x8435 1608 Service Event Log Severity Warning 2 Log Message The Rack And Enclosure MIB Agent could not create its main thread of execution The data contains the error code Event identifier cpqsvmsg dll 5641 Hex 0x8435 1609 Service Event Log Severity Warning 2 Log Message The Rack And Enclosure MIB Agent main thread did not terminate properly The data contains the error code Event identifier cpqsvmsg dll 5642 Hex 0x8435 160a Service Event Log Severity Warning 2 Log Message The Rack And Enclosure MIB Agent got an unexpected error code while waiting for an event The data contains the error code Event identifier cpqsvmsg dll 5643 Hex 0x8435 160b Service Event Log Severity Warning 2 Log Message The Rack And Enclosure MIB Agent did not respond to a request The data contains the error code Event identifier cpqsvmsg dll 5644 Hex 0x8435 1
171. us e cpqDaSpareCntlrindex e cpqDaSpareBusNumber Storage agents 33 e cpqDaSpareBay Supporting SNMP Trap Description Spare Status is now cpqDaSpareStatus NT Event ID 1064 Hex 0xc4350428 cpqstmsg dll Log Severity Error 3 Event Title Drive Array Physical Drive Status Change Log Message The physical drive in slot 4 port 5 bay 6 with serial number 7 has a new status of 2 SNMP Trap cpqDa5PhyDrvStatusChange 3029 in CPQIDA MIB Symptom Physical Drive Status Change This trap indicates that the agent has detected a change in the status of a drive array physical drive The variable cpaDaPhyDrvStatus indicates the current physical drive status User Action If the physical drive status is failed 3 or predictiveFailure 4 replace the drive Supporting SNMP Trap Data e sysName e cpqHoTrapFlags e cpqDaPhyDrvStatus e cpqDaPhyDrvCntlrindex e cpq DaPhyDrvBusNumber e cpqDaPhyDrvBay e cpqDaPhyDrvModel e cpqDaPhyDryFWRev e cpqDaPhyDrvSerialNum cpqDaPhyDrvFailureCode Supporting SNMP Trap Description Physical Drive Status is now cpqDaPhyDrvStatus NT Event ID 1065 Hex 0xc4350429 cpqstmsg dll Log Severity Error 3 Event Title Drive Array Accelerator Status Change Log Message The array accelerator board attached to the array controller in slot 4 has a new status of 2 SNMP Trap cpqDa5AccelStatusChange 3025 in CPQIDA MIB Symptom Accelerator Board Sta
172. used by a failure in the Remote Access Service or by a missing or invalid configuration Use the Insight Agent control panel to verify the Asynchronous Management configuration settings Use the Network control panel to verify the Remote Access configuration If this error persists reinstalling the Insight Agents or the Remote Access Service may correct this error For more information see the Insight Asynchronous Management documentation NT Event ID 1282 Hex 0x44350502 cpqnimsg dll Log Severity Information 1 Log Message Redundancy has been increased by the NIC in slot 1 port 2 Number of functional NICs in the team 3 SNMP Trap cpqNicRedundancylncreased 18003 in CPQNIC MIB Symptom This trap is sent any time a previously failed physical adapter in a connected logical adapter group returns to the OK condition This trap is not sent when a logical adapter group has connectivity restored from a Failed condition The cpqNicConnectivityRestored trap is sent instead This can be caused by replacing a faulty cable or by connecting a cable that was disconnected User Action None required Supporting SNMP Trap Data e sysName e cpqHoTrapFlags e cpqNiclfPhysAdapterSlot e cpqNiclfPhysAdapterPort e cpqNiclfLogMapAdapterOKCount Supporting SNMP Trap Description Redundancy increased by adapter in slot cpqNiclfPhysAdapterSlot port cpqNiclfPhysAdapterPort NT Event ID 1283 Hex 0xc4350503 cpqnimsg dll
173. v e cpqDaTapelibrarySerialNumber cpqDaTapeLibraryStatus Supporting SNMP Trap Description Status is now cpqDaTapeLibraryStatus for the tape library NT Event ID 1181 Hex 0x8435049d cpqstmsg dll Log Severity Warning 2 Event Title Drive Array Tape Library Door Status Change Log Message The tape library in slot 4 SCSI bus 5 SCSI target 6 has a new door status of 7 SNMP Trap cpqDaTapelibraryDoorStatusChange 3021 in CPQIDA MIB Symptom Tape Library Door Status Change This trap indicates that the agent has detected a change in the door status of a tape library The variable cpqDaTapelibraryDoorStatus indicates the current tape library door status The variable coqDaTapeLibraryScsiTarget indicates the SCSI ID of the tape library User Action If the tape library door is open close the tape library door Supporting SNMP Trap Data e sysName e cpqHoTrapFlags e cpqDaTapelibraryCntlrindex e cpqDaTapelLibraryScsiBus e cpqDaTapelLibraryScsiTarget Storage agents 54 e cpqDaTapelibraryScsiLun e cpqDaTapelibraryDoorStatus Supporting SNMP Trap Description The door is cpqDaTapelibraryDoorStatus for tape library NT Event ID 1182 Hex 0x8435049e cpqstmsg dll Log Severity Warning 2 Event Title Drive Array Tape Drive Status Change Log Message The tape drive in slot 4 SCSI bus 5 SCSI target 6 has a new status of 7 SNMP Trap cpqDa2TapeDriveStatusChange 3032 in CPQIDA MIB S
174. w memory condition Rebooting the server may correct this error Event identifier cpqstmsg dll 4612 Hex 0x8435 1204 Service Event Log Severity Warning 2 Log Message Could not read the registry subkey 1 This error can be caused by a corrupt registry or a low memory condition Rebooting the server may correct this error Event identifier cpqstmsg dll 4613 Hex 0x8435 1205 Service Event Log Severity Warning 2 Log Message Could not read the registry subkey 1 This error can be caused by a corrupt registry or a low memory condition Rebooting the server may correct this error Storage agents 81 Server agents Event Identifiers 256 774 Event identifier coqsvmsg dll 256 Hex 0x84350100 Service Event Log Severity Warning 2 Log Message The Server Agents service detected an error The insertion string is 1 The data contains the error code Event identifier cpqsvmsg dll 257 Hex 0x84350101 Service Event Log Severity Warning 2 Log Message The Server Agents service could not allocate memory The data contains the error code Event identifier cpqsvmsg dll 258 Hex 0x84350102 Service Event Log Severity Warning 2 Log Message The Server Agents service could not register with the Service Control Manager The data contains the error code Event identifier cpqsvmsg dll 259 Hex 0x84350103 Service Event Log Severity Warning 2 Log Message The Server Agents service c
175. wrSupplyStatus Supporting SNMP Trap Description A storage system power supply unit has become degraded NT Event ID 1107 Hex 0xc4350453 cpqstmsg dll Log Severity Error 3 Event Title SCSI Tape Drive Status Change Log Message The tape drive with SCSI target 6 connected to SCSI bus 5 of the controller in slot 4 has a new status of 2 SNMP Trap cpqTape4PhyDrvStatusChange 5016 in CPQSCSI MIB Symptom Tape Drive Status Change The Storage Agent has detected a change in the status of a Tape drive The current physical drive status is indicated in the cpqlapePhyDrvStatus variable Supporting SNMP Trap Data e sysName e cpqHoTrapFlags e cpq apePhyDrvCntlrindex e cpq apePhyDrvBuslndex e cpq apePhyDrvScsildIndex e cpq apePhyDrvStatus Supporting SNMP Trap Description Status is now cpqTapePhyDrvStatus NT Event ID 1119 Hex 0x8435045f cpqstmsg dll Log Severity Warning 2 Event Title SCSI Tape Drive Head Needs Cleaning Log Message The tape drive with SCSI target 6 connected to SCSI bus 5 of the controller in slot 4 needs to have a cleaning tape inserted and run SNMP Trap cpqTape3PhyDrvCleaningRequired 5008 in CPQSCSI MIB Symptom Tape Drive Cleaning Required trap The Insight Agent has detected a tape drive that needs to have a cleaning tape inserted and run This causes the tape drive heads to be cleaned Supporting SNMP Trap Data e sysName e cpqHoTrapFlags e cpq
176. x843504a0 cpqstmsg dll Log Severity Warning 2 Event Title Drive Array Tape Drive Replace Cleaning Tape Log Message The cleaning tape in the tape drive in slot 4 SCSI bus 5 SCSI target 6 needs to be replaced SNMP Trap cpqDaTapeDriveCleanTapeReplace 3024 in CPQIDA MIB Symptom Tape Drive Cleaning Tape Needs Replacing The agent has detected that an autoloader tape unit has a cleaning tape that has been fully used and therefore needs to be replaced with a new cleaning tape Supporting SNMP Trap Data e sysName e cpqHoTrapFlags e cpqDaTapeDrvCntlrindex e cpqDaTapeDrvBuslndex e cpqDaTapeDrvScsildIndex e cpqDaTapeDrvLunlndex Supporting SNMP Trap Description Cleaning tape needs replacing NT Event ID 1185 Hex 0x843504a1 cpqstmsg dll Log Severity Warning 2 Event Title Fibre Channel Controller Status Change Log Message The Fibre Channel Controller in slot 4 has a new status of 5 SNMP Trap cpqFca2HostCntlrStatusChange 16021 in CPQFCA MIB Symptom Fibre Channel Host Controller Status Change This trap indicates that the agent has detected a change in the status of a Fibre Channel Host Controller The variable cpqFcaHostCnilrStatus indicates the current controller status User Action If the controller status is failed replace the controller Supporting SNMP Trap Data e sysName e cpqHoTrapFlags e cpqFcaHostCntlrSlot e cpqFcaHostCntlrStatus e cpqFcaHostCntlrModel
177. x84350703 Service Event Log Severity Warning 2 Log Message The SNMP Agent is older than other components The SNMP Agent is older than the other components of the Server Agents Reinstall the entire Server Agents package to correct this error Event identifier coqsvmsg dll 1796 Hex 0x84350704 Service Event Server agents 124 Log Severity Warning 2 Log Message The 1 Agent is older than other components The 1 Agent is older than the other components of the Server Agents Reinstall the entire Server Agents package to correct this error Event identifier coqsvmsg dll 1800 Hex 0x84350708 Service Event Log Severity Warning 2 Log Message Unable to read security configuration information SNMP sets have been disabled Event identifier cpqsvmsg dll 1803 Hex 0xc435070b Service Event Log Severity Error 3 Log Message Unable to load a required library This error can be caused by a corrupt or missing file Reinstalling the Server Agents or running the Emergency Repair procedure may correct this error Event identifier coqsvmsg dll 1806 Hex 0x8435070e Service Event Log Severity Warning 2 Log Message The Server Agent service is not running The Server SNMP Agent has determined that the Server Agent service is not running Stop the SNMP service and restart the Server Agents service If the error persists reinstalling the Server Agents may correct this error Event identifier cpqsvmsg dll 1808
178. y controller in a duplexed pair has switched over to the active role The variable cpqFcaCntlrBoxloSlot indicates the new active controller index User Action Check the partner controller for problems If this was the result of a user initiated switch over no action is required Supporting SNMP Trap Data e sysName e cpqHoTrapFlags e cpqSsChassisName e cpqSsChassisTime Storage agents 53 e cpqFcaCntlrBoxloSlot Supporting SNMP Trap Description Controller in I O slot cpqFcaCntlrBoxloSlot is now active on chassis cpqSsChassisName NT Event ID 1180 Hex 0x8435049c cpqstmsg dll Log Severity Warning 2 Event Title Drive Array Tape Library Status Change Log Message The tape library in slot 4 SCSI bus 5 SCSI target 6 has a new status of 7 SNMP Trap cpqDa2TapeLibraryStatusChange 3031 in CPQIDA MIB Symptom Tape Library Status Change This trap indicates that the agent has detected a change in the status of a tape library The variable cpqDaTapeLibraryStatus indicates the current tape library status The variable cpqDaTapelibraryScsiTarget indicates the SCSI ID of the tape library User Action If the tape library is failed check the tape library front panel Supporting SNMP Trap Data e sysName e cpqHoTrapFlags e cpqDaTapelLibraryCntlrindex e cpqDaTapelLibraryScsiBus e cpqDaTapelLibraryScsiTarget e cpqDaTapelLibraryScsiLun e cpqDaTapeLibraryModel e cpqDaTapelibraryFWRe
179. ymptom Tape Drive Status Change This trap indicates that the agent has detected a change in the status of a tape drive The variable coqDaTapeDrvStatus indicates the current tape status The variable cpqDaTapeDrvScsildIndex indicates the SCSI ID of the tape drive User Action If the tape is failed check the tape and all SCSI connections Supporting SNMP Trap Data e sysName e cpqHoTrapFlags e cpqDaTapeDrvCntlrindex e cpqDaTapeDrvBuslndex e cpqDaTapeDrvScsildIndex e cpqDaTapeDrvLunlndex e cpqDaTapeDrvyName e cpqDaTapeDrvFwRev e cpqDaTapeDrvSerialNumber e cpq DaTapeDrvStatus Supporting SNMP Trap Description Status is now cpqDaTapeDrvStatus for a tape drive NT Event ID 1183 Hex 0x8435049f cpqstmsg dll Log Severity Warning 2 Event Title Drive Array Tape Drive Cleaning Required Log Message The tape drive in slot 4 SCSI bus 5 SCSI target 6 requires cleaning SNMP Trap cpqDaTapeDriveCleaningRequired 3023 in CPQIDA MIB Symptom Tape Drive Cleaning Required trap The agent has detected a tape drive that needs to have a cleaning tape inserted and run This causes the tape drive heads to be cleaned Supporting SNMP Trap Data e sysName e cpqHoTrapFlags e cpqDaTapeDrvCntlrindex e cpqDaTapeDrvBuslndex e cpqDaTapeDrvScsildIndex e cpqDaTapeDrvLunlndex Supporting SNMP Trap Description Cleaning is needed for the tape drive Storage agents 55 NT Event ID 1184 Hex 0
Download Pdf Manuals
Related Search
Related Contents
AVANT / RITMO - Cerámicas Gala. FI 6/820-fto A3-F Clique aqui e faça o do manual de instruções do Agilent 1200 Series High Performance Autosamplers & Micro Well Canon MultiPASS C555 User's Manual Direct_Soir_473-2009-0109-page6 Copyright © All rights reserved.
Failed to retrieve file