Home
HP NC510C User's Manual
Contents
1. TCP IP Offload Engine UTP unshielded twisted pair Acronyms and abbreviations 17 Index bracket low profile 9 C cable configuration 10 cable connectors 11 electrostatic discharge 8 16 F features 6 G grounding methods 16 installation overview 8 installing adapters 9 N NIC LEDs 6 R regulatory compliance notices 13 S specifications 10 V ventilation 4 Index 18
2. 13 ee D de SR DR ee et ean aesainens 13 CCEA EE a NE a E ne de aaie 14 Japanese class A OURS Rain haine om TEE a ea den EE 14 Korean regulatory MONGE x caistcecipapaituteiony een dti tte eien 14 EE leede aera SES eae a R E E eR a E reS E EE A Ee E E E e 14 TEE 14 Disposal of waste equipment by users in private households in the European Union 15 EEE E E 16 Preventing electrostatic E 16 Grounding methods to prevent electrostatic discharges cissaijaasisverne cotaiadensasatisemarasventardecnsbenaidenaaciaans 16 EE 17 Eege 18 Contents 3 Technician notes In this section Warnings cautions ENEE Eer A ene te E ERT A Warnings cautions and notes Z WARNING Only authorized technicians trained by HP should attempt to repair this equipment All troubleshooting and repair procedures are detailed to allow only subassembly module level repair Because of the complexity of the individual boards and subassemblies no one should attempt to make repairs at the component level or to make modifications to any printed wiring board Improper repairs can create a safety hazard Z WARNING To reduce the risk of electric shock personal injury and damage to the equipment Do not attempt to service any parts of the equipment other than those specified in the following procedure Any other activities may require that you shut down the server and remove the power cord Installation and maintenance of this product must be performed by individual
3. com products servers networking index html Technician notes 4 HP contact information For the name of the nearest HP authorized reseller e Inthe United States see the HP US service locator webpage hitp www hp com service locator e In other locations see the Contact HP worldwide in English webpage http welcome hp com country us en wwcontact html For HP technical support e In the United States for contact options see the Contact HP United States webpage http welcome hp com country us en contact_us html To contact HP by phone o Call 1 800 HP INVENT 1 800 474 6836 This service is available 24 hours a day 7 days a week For continuous quality improvement calls may be recorded or monitored o If you have purchased a Care Pack service upgrade call 1 800 633 3600 For more information about Care Packs refer to the HP website http www hp com e In other locations see the Contact HP worldwide in English webpage http welcome hp com country us en wweontact html Technician notes 5 Introduction In this section Overview LED indicators 6 Overview The HP NC510C PCle 10 Gb Server Adapter is a high performance multifunction Ethernet adapter that delivers up to 10 Gbps over 4 pair twin axial cabling The network connection is made through a single port CX4 connector The LED indicator shows the activity and link status See LED indicators on page 6 for details The NC510C adapter wh
4. not emit hazardous laser radiation Regulatory compliance notices Each laser product complies with 21 CFR 1040 10 and 1040 11 except for deviations pursuant to Laser Notice No 50 dated May 27 2001 and with IEC 60825 1 1993 A2 2001 Z WARNING Use of controls or adjustments or performance of procedures other than those specified herein or in the laser product s installation guide may result in hazardous radiation exposure To reduce the risk of exposure to hazardous radiation e Do not try to open the module enclosure There are no user serviceable components inside e Do not operate controls make adjustments or perform procedures to the laser device other than those specified herein e Allow only HP Authorized Service technicians to repair the unit The Center for Devices and Radiological Health CDRH of the U S Food and Drug Administration implemented regulations for laser products on August 2 1976 These regulations apply to laser products manufactured from August 1 1976 Compliance is mandatory for products marketed in the United States Disposal of waste equipment by users in private households in the European Union This symbol on the product or on its packaging indicates that this product must not be disposed of with your other household waste Instead it is your responsibility to dispose of your waste equipment by handing it over to a designated collection point for the recycling of waste electrical and electronic equipm
5. HP NC510C PCle 10 Gigabit Server Adapter User Guide WH Part Number 437524 00B February 2007 Second Edition Copyright 2006 2007 Hewlett Packard Development Company L P The information contained herein is subject to change without notice The only warranties for HP products and services are set forth in the express warranty statements accompanying such products and services Nothing herein should be construed as constituting an additional warranty HP shall not be liable for technical or editorial errors or omissions contained herein Audience assumptions This document is for the person who installs administers and troubleshoots servers and storage systems HP assumes you are qualified in the servicing of computer equipment and trained in recognizing hazards in products with hazardous energy levels Contents RO RO D OS aac RER dna M RE 4 Warnings SEUNG and HEEN 4 Where to go for additional helene nn 4 HP ege EE eege tee E E ee E EES 5 o e aA E E E E EA 6 EE 6 HEEN 6 herlig TAG RIOT ER NE PS EN OP SU eaiail 8 aseene 8 Preventing electrostatic E 8 Installing an adapter in a server Rene main ni oil 9 Installing a low profile E 9 il 10 EE 10 General specifications suisses 10 Compliance Peete ae en rae BER ae NS Ne ee eee ee eee eee 10 Power and environmental specifications us 11 CX4 connector pinout description sise 11 CD RS de Re 13 Regulatory compliance identification numbers 13 OO TEE 13 eege Eeer
6. c sensitive component or assembly Grounding methods to prevent electrostatic discharge Several methods are used for grounding Use one or more of the following methods when handling or installing electrostatic sensitive parts e Use a wrist strap connected by a ground cord to a grounded workstation or computer chassis Wrist straps are flexible straps with a minimum of 1 megohm 10 percent resistance in the ground cords To provide proper ground wear the strap snug against the skin e Use heel straps toe straps or boot straps at standing workstations Wear the straps on both feet when standing on conductive floors or dissipating floor mats e Use conductive field service tools e Use a portable field service kit with a folding static dissipating work mat If you do not have any of the suggested equipment for proper grounding have an authorized reseller install the part For more information on static electricity or assistance with product installation contact an authorized reseller Electrostatic discharge 16 Acronyms and abbreviations CSA Canadian Standards Association DMA direct memory access IEEE Institute of Electrical and Electronics Engineers iSCSI Internet Small Computer System Interface MSI Message Signaled Interrupt MSI X Message Signaled Interrupt Extended PCI Express Peripheral Component Interconnect Express RDMA Remote Direct Memory Access RSS Receive Side Scaling TOE
7. dasuntermeseneonneeoninns 11 CXA connedoi pineut EE Oostende ant lanta an 11 CX4 Twin axial cable The NC510C adapter uses a 10Base CX4 copper interface to deliver Gigabit Ethernet over four twin axial copper cable pairs as specified in the IEEE 802 3ak standard For troubleshooting and other information about cabling see the CX4 connector pinout description on page 11 General specitications specifications 4x InfiniBand SFF 8470 Compliance IEEE 802 1p QoS 802 1Q VLANs 802 3ae 10 Gigabit Ethernet 802 3ak CX4 802 3x flow control Safety UL Mark US and Canada EN 60950 Emissions FCC Class A VCCI Class A BSMI Class A CISPR 22 Class A ACA Class A EN55022 Class A EN55024 1 ICES 003 Class A MIC Class A Specifications 10 PCle v1 1 RoHS 5 Exemption 7 IPv4 IPv CE ACPI 1 1a Microsoft WHQL Windows Hardware Quality Labs Server Design Guide version 3 0 SDG 3 0 Power and environmental specifications Power and environmental specifications Operating Temperature 32 to 131 F 0 to 55 C Humidity 10 to 90 non condensing Non operating Temperature 85 to 185 F 65 to 85 C Humidity 5 to 95 1 68 A 12 V and 0 49 A 3 3 V maximum CX4 connector pinout description CET Connsaorpin signal name Signal Shield Signal Shield Signal Shield Link Shield Specifications 11 S16 S2 G9 l Specifications 12 Regulatory compliance not
8. ent The separate collection and recycling of your MM waste equipment at the time of disposal will help to conserve natural resources and ensure that it is recycled in a manner that protects human health and the environment For more information about where you can drop off your waste equipment for recycling please contact your local city office your household waste disposal service or the shop where you purchased the product Regulatory compliance notices 15 Electrostatic discharge In this section Preventing elecirostotie CNS icici concen enone ier meme Gnl 16 Grounding methods to prevent electrostatic discharge cccsscccessseeeeseeeeseeceeeeeceseeceeeeeensaeeeeeseeeeseeeneas 16 Preventing electrostatic discharge To prevent damaging the system be aware of the precautions you need to follow when setting up the system or handling parts A discharge of static electricity from a finger or other conductor may damage system boards or other static sensitive devices This type of damage may reduce the life expectancy of the device To prevent electrostatic damage e Avoid hand contact by transporting and storing products in static safe containers e Keep electrostatic sensitive parts in their containers until they arrive at static free workstations e Place parts on a grounded surface before removing them from their containers e Avoid touching pins leads or circuitry e Always be properly grounded when touching a stati
9. ices In this section Regulatory compliance identification numbers cessera 13 ee EE eege 13 PETG diem ennemi eine 13 e cn nan moe comencoceneraaonn mnt son 13 RO TE A A S EE E RA r ETA le ne ln DE ETE ET EE 14 ST de ORI E enron E ENA N N 14 D ee eebe ee 14 Beete 14 Ee e nn Ne nn ie eee lee 14 Disposal of waste equipment by users in private households in the European Union 15 Regulatory compliance identification numbers For the purpose of regulatory compliance certifications and identification this product has been assigned a unique regulatory model number The regulatory model number can be found on the product nameplate label along with all required approval markings and information When requesting compliance information for this product always refer to this regulatory model number The regulatory model number is not the marketing name or model number of the product Class equipment This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful in
10. ich ships with a standard height chassis bracket and also includes a low profile chassis bracket is a supported option for selected HP ProLiant servers and offers support for both standard and low profile slots In addition to standard HP network server adapter features the NC510C is capable of supporting teaming for load balancing and failover Receive Side Scaling TCP IP Offload Engine TOE Accelerated iSCSI and Remote Direct Memory Access RDMA that can significantly improve server throughput while reducing host CPU utilization The teaming TOE accelerated iSCSI and RDMA multifunction features are planned for future near term software releases LED indicators The NC510C adapter has a single CX4 connector and an LED indicator that shows Link Act link activity Standard height and low profile brackets are shown below with CX4 connectors and the LED indicator Ad JS Link Act J CL The NC510C 10 Gigabit Server Adapter LED indicator operates as described in the following table Introduction 6 Link Act Of No link to the adapter is established The adapter is not receiving power or the cable connection is faulty On Green Link to the adapter is established The adapter is receiving power and the cable connection is good Flashing Green The adapter is sending or receiving network data at up to 10 Gbps Introduction 7 Installing an adapter In this section Joe cee ce pene on ie indie
11. installing a PCI Express card and avoiding electric shock hazards Preventing electrostatic discharge To prevent damaging the system be aware of the precautions you need to follow when setting up the system or handling parts A discharge of static electricity from a finger or other conductor may damage system boards or other static sensitive devices This type of damage may reduce the life expectancy of the device To prevent electrostatic damage e Avold hand contact by transporting and storing products in static safe containers e Keep electrostatic sensitive parts in their containers until they arrive at static free workstations e Place parts on a grounded surface before removing them from their containers e Avoid touching pins leads or circuitry e Always be properly grounded when touching a static sensitive component or assembly Installing an adapter 8 Installing an adapter in a server See the HP ProLiant server documentation for additional information on how to safely install a PCI Express card in the server ZA CAUTION f the server is not PCI Hot Plug com liant power it down and unplug the power cord g p p plug P from the power outlet before removing the server access panel Failure to do so may damage the adapter or server 1 Power down the server 2 Remove the power cord and server access panel Then remove the cover bracket from a PCI Express slot Z WARNING To reduce the risk of personal injury fro
12. m hot surfaces allow the drives and the internal system components to cool before touching them 3 Firmly seat the adapter in a PCI Express slot and secure the adapter bracket A NOTE For 1U type servers you may need to replace the standard profile bracket with a low profile bracket See Installing a low profile bracket on page 9 4 Replace the access panel and plug in the power cord Installing a low protile bracket You may have to install a low profile bracket to complete the product installation The low profile bracket replaces the existing standard profile bracket shipped on the product To install a low profile bracket 1 Using a correctly sized Phillips head screwdriver carefully remove the two board lock screws located at the top and bottom of the connector Some versions may have small spring clips on the CX4 connector posts that also must be removed 2 Remove the standard profile bracket and place the low profile bracket over the connector Be careful not to damage the connector or bend the low profile bracket 3 Reinstall the two Phillips screws Reinstallation of the spring clips found on some versions is optional because the clips have negligible effect on the bracket support and EMI Installing an adapter 9 Specifications In this section EOIN a asa NN Le D ate een 10 El a dou nodules 10 RE 10 Power and environmental SPECNCONONG i yeissensssvnccniscrnianenientensnuceraiierinacbarsents cheiaminiagiesrme
13. ne nee to 8 Wat 8 hstaling ah IE aient imminente 9 aline silas pratile brac EE 9 Installation overview This section describes installation precautions how to install the adapter and how to connect the network cable Z WARNING To reduce the risk of personal injury or damage to the equipment consult the safety information and user documentation provided with the server before attempting the installation Many servers are capable of providing energy levels that are considered hazardous and are intended to be serviced only by qualified personnel who have been trained to deal with these hazards Do not remove enclosures or attempt to bypass any interlocks that may be provided for the purpose of removing these hazardous conditions Z WARNING Installation of this adapter should be performed by individuals who are both qualified in P pe y the servicing of computer equipment and trained in the hazards associated with products capable of producing hazardous energy levels This adapter is intended to be installed in Certified UL or CSA ITE equipment having instructions for adding and removing user installed components such as PCI PCI X and PCI Express devices Refer to the equipment instructions to verify that it is suitable for user installed components and that it has the power capacity to support all of the installed components EI NOTE Before removing the cover of your server refer to the HP documentation for the proper methods for
14. s who are knowledgeable about the procedures precautions and hazards associated with the product Z WARNING To reduce the risk of electric shock or damage to the equipment Do not disable the power cord grounding plug The grounding plug is an important safety feature Plug the power cord into a grounded earthed electrical outlet that is easily accessible at all times Unplug the power cord from the power supply to disconnect power to the equipment Do not route the power cord where it can be walked on or pinched by items placed against it Pay particular attention to the plug electrical outlet and the point where the cord extends from the server CAUTION To properly ventilate the system you must provide at least 7 6 cm 3 0 in of clearance at the front and back of the server CAUTION The server is designed to be electrically grounded earthed To ensure proper operation plug the AC power cord into a properly grounded AC outlet only EI NOTE Any indications of component replacement or printed wiring board modifications may void any warranty Where to go for additional help In addition to this guide information about software drivers and utilities is available on the HP ProLiant Networking Software CD that shipped with the adapter HP updates networking software frequently to include new functionality and features For the latest driver firmware and documentation updates go to the HP website http h18004 www1 hp
15. terference in which case the user will be required to correct the interference at personal expense Modifications The FCC requires the user to be notified that any changes or modifications made to this device that are not expressly approved by Hewlett Packard Company may void the user s authority to operate the equipment Cables Connections to this device must be made with shielded cables with metallic RFI EMI connector hoods in order to maintain compliance with FCC Rules and Regulations Regulatory compliance notices 13 Canadian notice This Class A digital apparatus meets all requirements of the Canadian Interference Causing Equipment Regulations Cet appareil num rique de la classe A respecte toutes les exigences du R glement sur le mat riel brouilleur du Canada Japanese class A notice COMBI TRUE ES CE A ER eR VCCI DE ESOC 2 7 XA MEME CT DORE RER CHEATS amp EE Ek EC LE LOGE EAN RARE CH SLIBRENSILBHVEF Korean regulatory notice Az 7 7 248 gas ol AIS AFSC Yyy g5 7 EA LE Also AS FASHA Bej ge gep s TYE Hoe 714 Jimin BSMI notice SSeS exe FT VE de EER RE AAAS gt ORE ISR TA TE BLP PASS AE ORR EHR e Laser compliance This product may be provided with an optical storage device that is CD or DVD drive and or fiber optic transceiver Each of these devices contains a laser that is classified as a Class 1 Laser Product in accordance with US FDA regulations and the IEC 60825 1 The product does
Download Pdf Manuals
Related Search
Related Contents
2015 AR-ONE - Starcraft RV Aiphone PS-24E User's Manual BELUGA - Invacare Descargar Ficha técnica DELL PowerConnect W-IAP103 Sistema de Contabilidade Gerencial Contábil-V4 Indoor Fogger - KellySolutions.com User Manual - SemiconductorStore.com Copyright © All rights reserved.
Failed to retrieve file