Home
HP AXCRN3-2G User's Manual
Contents
1. 5 5 Processing Time For cluster config Might Take Longer On A Head Node With Improved Availability The cluster config utility processing time can take approximately ten minutes longer if it is run on a head node that is configured for improved availability with Serviceguard when the remaining nodes of the cluster are up and running After the entire system has been imaged and booted you might need to re run the cluster config procedure to modify the node configuration If the other node in the availability set with the head node is up and running the Serviceguard daemons attempt to establish Serviceguard related communication with the node when they are restarted Because the other node in the availability set is not actively participating in a Serviceguard cluster it will not respond to the Serviceguard communication The Serviceguard software on the head node retries this communication until the communication times out On a system running with the default Serviceguard availability configuration the timeout is approximately ten minutes 5 6 Notes That Apply To Imaging The notes in this section apply to propagating the golden image to all nodes which is accomplished when you invoke the startsys command 5 6 1 HP Proliant DL140 G3 and DL145 G3 Node Imaging Fails When Graphics Cards Are Present As described in Discovery of HP ProLiant DL140 G3 and DL145 G3 Nodes Fails When Graphics Cards Are Present page 26 the discovery and im
2. Index B base operating system 15 C C52xcgraph error 26 clear_counters command 45 client node disk partition 16 cluster_config utility 26 C52xcgraph error message 26 new features 16 CP3000 system 37 CP4000 system 39 CP6000 system 41 SIGUSR2 signal 46 D data corruption on ext3 file systems 31 discover command new features 16 discover utility 26 documentation 47 additional publications 12 changed in this release 18 compilers 12 FlexLM 11 HowTo 8 HP XC System Software 8 Linux 11 LSF 10 manpages 12 master firmware list 8 Modules 11 MPI 11 MySQL 11 Nagios 10 pdsh 10 reporting errors in 13 rrdtool 10 SLURM 10 software RAID 12 Supermon 10 syslog ng 10 SystemImager 10 TotalView 12 E ext3 file system 31 E failed to find InfiniBand ports 26 feedback e mail address for documentation 13 firmware version 19 found no adapter info on IRONOO 26 H hardware preparation tasks 21 hardware support 15 HowTo 18 Web site 8 HP documentation providing feedback for 13 HP Scalable Visualization Array see SVA HP MPI fork restrictions with kernel version 35 fork restrictions with OFED 35 init failed 35 multiple rail support 35 iLO 43 iLO2 hang 43 InfiniBand multiple rail support 35 InfiniBand interconnect failed to find ports 26 inode information 31 installation notes 23 integrated lights out console management device see iLO see iLO2 inter
3. Table of Contents 3 5 6 1 HP ProLiant DL140 G3 and DL145 G3 Node Imaging Fails When Graphics Cards Are Present ee 27 DOWN a ona GR dM dq 29 6 1 Do Not Upgrade If You Want Or Require The Voltaire InfiniBand Software Stack 29 7 System Administration Management and Monitoring 24 7 1 Perform A Dry Run Before Using The si updateclient Utility To Update Nodes 31 7 2 Possible Problem With ext3 File Systems On SAN Storage case bibas na 31 8 HP XC System Software On Red Hat Enterprise Linux dd 8 1 Enabling 32 bit Applications To Compile and Run riri rtt bres hne ann 33 Programming and User Envirentteni nn 35 9 1 MPI and OPED InfiniBand Stack Fork Restrietiors Ls eei Leer b en 35 9 2 InfiniBand Multiple R il SUbDOPE aussage 35 9 3 Benign Messages From HP MPI Version 2231 seinen 35 a 2000 E aM T Shoe Pato 600 T eso 39 PES Ec A 4 12 1 Network Boot Operation and Imaging Failures on HP Integrity rx2600 Systems 41 12 2 Notes That Apply To The Management Processor curra nee 41 12 2 1 Required Task Change MP Settings on Console Switches eese 41 12 2 2 MP Disables DHCP Automatically in A rU UP CERE DRM I VE EV EAE 41 122 3 Finding the IP Address of an MP un ai ee 41 13 Integrated Lights Out Console Management Devices 43 19 131022 Devices In Server Blades Can Hang ann een 43 MEN Ne oue conu A DURUM aac ee 45 iia dias In
4. Issues have been reported when an ext3 file system fills up to the point where ENOSPC is returned to write requests for a long period of time and the file system is subsequently unmounted A forced check is initiated fsck fy before the next mount It appears that the fsck checks might corrupt the file system inode information This problem has been seen only on fibre channel SAN storage it has not been seen with directly attached storage or NFS storage For more information about details and work arounds consult Bugzilla number 175877 at the following URL https bugzilla redhat com bugzilla show_bug cgi id 175877 7 1 Perform A Dry Run Before Using The si_updateclient Utility To Update Nodes 31 32 8 HP XC System Software On Red Hat Enterprise Linux The notes in this chapter apply when the HP XC System Software is installed on Red Hat Enterprise Linux 8 1 Enabling 32 bit Applications To Compile and Run To compile and run 32 bit applications on a system running HP XC System Software on Red Hat Enterprise Linux 4 on HP Integrity platforms use the following commands to install the glibc 2 3 4 2 25 1686 rpm from the HP XC distribution media DVD mount dev cdrom cd mnt cdrom LNXHPC RPMS rpm ivh glibc 2 3 4 2 25 1686 rpm 8 1 Enabling 32 bit Applications To Compile andRun 33 34 9 Programming and User Environment This chapter contains information that applies to the programming and user environment
5. correctly If your system has a NC510F 10 GB Ethernet card run the following commands to load the driver depmod a modprobe v unm nic Then edit the etc modprobe conf file and specify unm as the driver for the eth device assigned to the NC510F driver 4 1 Manual Installation Required For NC510F Driver 23 24 5 System Discovery Configuration and Imaging we This chapter contains information about configuring the system Notes that describe additional configuration tasks are mandatory and have been organized chronologically Perform these tasks in the sequence presented in this chapter The HP XC system configuration procedure is documented in the HP XC System Software Installation Guide IMPORTANT Before you begin depending upon the cluster platform type see Chapter 10 page 37 Chapter 11 page 39 or Chapter 12 page 41 to determine if additional platform specific notes apply to the system discovery configuration or imaging process 5 1 Notes That Apply Before You Invoke The cluster prep Utility Read the notes in this section before you invoke the cluster_prep utility 5 1 1 Required Task for Some NIC Adapter Models Verify Correct NIC Device Driver Mapping On head nodes installed with dual fiber NIC server adapter models NC6170 or NC7170 Ethernet ports might be reordered between the Kickstart kernel and the subsequent HP XC kernel reboot Use the procedure described in this section to correct
6. 1 12 Support Por HE Unified Parallel Canina ated tci ee 17 1 13 Documentation Changer ana 18 2 Important lese Henne 19 2 1 Firmware scii MAP nn00 0 S n SX 19 22 Patches ae 19 a Fehr Ferien au 2 3 1 Upgrading BMC Firmware On HP ProLiant DL140 G2 and DL145 G2 Nodes 21 4 Software Installation On The Head Node seen 23 4 1 Manual Installation Required For NCSLOP Dive urere tester id da c aeter a 23 5 System Discovery Configuration and Imaging 25 5 1 Notes That Apply Before You Invoke The cluster prep Utility sse 25 5 1 1 Required Task for Some NIC Adapter Models Verify Correct NIC Device Driver Mapping erpii ii e E Eg CE EEA A e O E T EEr 25 5 2 Notes That Apply To The Discover Process print ta 26 5 2 1 Discovery of HP ProLiant DL140 G3 and DL145 G3 Nodes Fails When Graphics Cards Are Presenter A E E samulavan Map Maine soneteND Sines 26 5 3 Notes That Apply Before You Invoke The cluster config Utility sese 26 5 3 1 Adhere To Role Assignment Guidelines for Improved Availability ss 26 5 4 Benign Message From C52xcgraph During cluster config iicet ts 26 5 5 Processing Time For cluster config Might Take Longer On A Head Node With Improved Availability e no RUNER A EER SRE 27 be Notes That Apply To Birds nee 27
7. Ixc command is one of several commands that are part of the process to upgrade HP XC System Software on Red Hat Enterprise Linux to the next release of HP XC System Software on Red Hat Enterprise Linux The software upgrade process is documented in the HP XC System Software Installation Guide This command is never run for any reason other than during a software upgrade Documentation The upgradesys Ixc utility is run immediately after the head node is upgraded with the new XC release software and any other required third party software products The upgradesys Ixc utility performs the following tasks to upgrade your system o Makes abackup copy of the database from the previous release o Modifies attributes in the database to signify that the sys tem has been upgraded o Removes RPMs from the previous release that are no longer supported in the new release o Executes internal migration scripts to migrate system con figuration data to the new release format OPTIONS The upgradesys Ixc command does not have any options FILES opt hptc Ixc upgrade etc gupdate d Location of migration scripts lopt hptc etc sysconfig upgrade upgradesys dbbackup date time stamp Location of database backup var log upgradesys lxc upgradesys lxc log Contains the results of the RPM upgrade process and lists customized configuration files SEE ALSO preupgradesys lxc 8 HP XC System Software Installation Guide 15 2 HP XC Manpages 49 50
8. by you must choose one of the items The preceding element can be repeated an arbitrary number of times Separates items in a list of choices WARNING A warning calls attention to important information that if not understood or followed will result in personal injury or nonrecoverable system problems CAUTION A caution calls attention to important information that if not understood or followed will result in data loss data corruption or damage to hardware or software IMPORTANT This alert provides essential information to explain a concept or to complete a task NOTE A note contains additional information to emphasize or supplement important points of the main text HP XC and Related HP Products Information The HP XC System Software Documentation Set the Master Firmware List and HP XC HowTo documents are available at this HP Technical Documentation Web site http www docs hp com en linuxhpc html The HP XC System Software Documentation Set includes the following core documents HP XC System Software Release Notes Describes important last minute information about firmware software or hardware that might affect the system This document is not shipped on the HP XC documentation CD It is available only on line HP XC Hardware Preparation Guide Describes hardware preparation tasks specific to HP XC that are required to prepare each supported hardware model for installation and configuration including required node and s
9. environment See the HP XC QuickSpecs and the SVA documentation set for more information about SVA features The SVA documentation set is included on the HP XC Documentation CD Because the SVA RPMs are included on the HP XC distribution media the SVA installation process has been integrated with the HP XC installation process The HP XC System Software Installation Guide was revised where appropriate to accommodate SVA installation and configuration procedures 1 5 Partition Size Limits on Installation Disk Because the installation disk size can vary partition sizes are calculated as a percentage of total disk size However using a fixed percentage of the total disk size to calculate the size of each disk partition can result in needlessly large partition sizes when the installation disk is larger than 36 GB Thus for this release limits have been set on the default partition sizes to leave space on the disk for other user defined file systems and partitions 1 6 More Flexibility in Customizing Client Node Disk Partitions You can configure client node disks on a per image and per node basis to create an optional scratch partition to maximize file system performance Partition sizes can be fixed or they can be based on a percentage of total disk size To do so you set the appropriate variables in the opt hptc systemimager etc make partitions sh file or set the variables in user defined files with a part extension The procedure that d
10. following release notes are specific to the QsNet interconnect 14 1 InfiniBand Interconnect 45 14 3 1 Possible Conflict With Use of SIGUSR2 The Quadrics QsNet software internally uses SIGUSR2 to manage the interconnect This can conflict with any user applications that use SIGUSR2 including for debugger use To work around this conflict set the environment variable LIBELAN4 TRAPSIG for the application to a different signal number other than the default value 12 that corresponds to SIGUSR2 Doing this instructs the Quadrics software to use the new signal number and SIGUSR2 can be once again used by the application Signal numbers are define in the usr include asm signal h file 14 3 2 The qsnet Database Might Contain Entries To Nonexistent Switch Modules 46 ET Depending on the system topology the qsnet diagnostics database might contain entries to nonexistent switches This issue is manifested as errors reported by the usr bin qsctrl utility similar to the following qsctrl qsctrl failed to initialise module QRONO3 no such module 7 In the previous example the switch modules table in the qsnet database is populated with QRONO3 even though the QRONO3 module is not physically present This problem has been reported to Quadrics Ltd To work around this problem delete the QRONO3 entry and any other nonexistent switch entries from the switch modules table and restart the swmlogger service mysql u root p
11. particularly the MySQL Reference Manual Related Software Products and Additional Publications This section provides pointers to Web sites for related software products and provides references to useful third party publications The location of each Web site or link to a particular topic is subject to change without notice by the site provider Linux Web Sites http www redhat com Home page for Red Hat distributors of Red Hat Enterprise Linux Advanced Server a Linux distribution with which the HP XC operating environment is compatible http www linux org docs index html This Web site for the Linux Documentation Project LDP contains guides that describe aspects of working with Linux from creating your own Linux system from scratch to bash script writing This site also includes links to Linux HowTo documents frequently asked questions FAQs and manpages http www linuxheadquarters com Web site providing documents and tutorials for the Linux user Documents contain instructions for installing and using applications for Linux configuring hardware and a variety of other topics http www enu or Home page for the GNU Project This site provides online software and information for many programs and utilities that are commonly used on GNU Linux systems Online information include guides for using the bash shell emacs make cc gdb and more MPI Web Sites http www mpi forum or Contains the official MPI st
12. 9 MPI and OFED InfiniBand Stack Fork Restrictions With the introduction of the OFED InfiniBand stack in this release MPI applications cannot call fork popen and system between MPI Init and MPI Finalize This is known to affect some applications like NWChem 9 2 InfiniBand Multiple Rail Support HP MPI provides multiple rail support on OpenFabric through the MPI IB MULTIRAIL environment variable This environment variable is ignored by all other interconnects In multi rail mode a rank can use up to all cards on its node but it is limited to the number of cards on the node to which it is connecting For example if rank A has three cards rank B has two cards and rank C has three cards then connection A B uses two cards connection B C uses two cards and connection A C uses three cards Long messages are striped among all the cards on that connection to improve bandwidth By default multi card message striping is off To turn iton specify e MPI IB MULTIRAIL N where N is the number of cards used by a rank e IfN lt 1 message striping is not used e If Nis greater than the maximum number of cards M on that node all M cards are used e Ifl lt N lt M message striping is used on N cards or less If you specify e MPI_IB_MULTIRAIL the maximum possible cards are used On a host all the ranks select all the cards in a series For example given 4 cards and 4 ranks per host e rank 0 will use cards 0 1 2 3 e rank 1 will u
13. HP XC System Software Release Notes Version 3 2 HP Part Publishe Number A XCRN32G d March 2008 Copyright 2007 2008 Hewlett Packard Development Company L P Confidential computer software Valid license from HP required for possession use or copying Consistent with FAR 12 211 and 12 212 Commercial Computer Software Computer Software Documentation and Technical Data for Commercial Items are licensed to the U S Government under vendor s standard commercial license The information contained herein is subject to change without notice The only warranties for HP products and services are set forth in the express warranty statements accompanying such products and services Nothing herein should be construed as constituting an additional warranty HP shall not be liable for technical or editorial errors or omissions contained herein AMD and AMD Opteron are trademarks or registered trademarks of Advanced Micro Devices Inc FLEXIm is a trademark of Macrovision Corporation InfiniBand is a registered trademark and service mark of the InfiniBand Trade Association Intel Itanium and Xeon are trademarks or registered trademarks of Intel Corporation in the United States and other countries Linux is a U S registered trademark of Linus Torvalds LSF and Platform Computing are trademarks or registered trademarks of Platform Computing Corporation Myrinet and Myricom are registered trademarks of Myricom Inc Nagios is a registered tra
14. I is an implementation of the MPI standard that has been integrated in HP XC systems The home page and documentation is located at the following Web site http www hp com go mpi HP Serviceguard HP Serviceguard is a service availability tool supported on an HP XC system HP Serviceguard enables some system services to continue if a hardware or software failure occurs The HP Serviceguard documentation is available at the following Web site http www docs hp com en ha html HP Scalable Visualization Array The HP Scalable Visualization Array SVA is a scalable visualization solution that is integrated with the HP XC System Software The SVA documentation is available at the following Web site http www docs hp com en linuxhpc html HP Cluster Platform The cluster platform documentation describes site requirements shows you how to set up the servers and additional devices and provides procedures to operate and manage the hardware These documents are available at the following Web site http www docs hp com en linuxhpc html HP Integrity and HP ProLiant Servers Documentation for HP Integrity and HP ProLiant servers is available at the following Web site http www docs hp com en hw html Related Information This section provides useful links to third party open source and other related software products Supplementary Software Products This section provides links to third party and open source software
15. P Automatically A known limitation exists with the MP firmware that causes the MP to disable DHCP automatically To work around this issue the HP XC software performs the discovery phase with DHCP enabled You must then perform a procedure to change the addresses on all MPs in the system to use the address received from DHCP as a static address For more information on how to perform this procedure contact the HP XC Support Team at xc supportGhp com Finding the IP Address of an MP Because the IP addresses for the MPs are being set statically for this release if a node must be replaced you must set the IP address for the MP manually when the node is replaced To find the IP address look up the entry for the MP in the etc dhcpd conf file The MP naming convention for the node is cp node name 12 1 Network Boot Operation and Imaging Failures on HP Integrity rx2600 Systems 41 42 13 Integrated Lights Out Console Management Devices This chapter contains information that applies to the integrated lights out iLO and iLO2 console management device 13 1 iLO2 Devices In Server Blades Can Hang There is a known problem with the iLO2 console management devices that causes the iLO2 devices to hang This particular problem has very specific characteristics This problem is typically seen within one or two days of the initial cluster installation e Most of the time but not always all iLO2 devices in a particular enclosure han
16. aging processes might fail on HP ProLiant DL140 G3 or DL145 G3 servers containing graphics cards The work around for the discovery failure is described in Discovery of HP ProLiant DL140 G3 and DL145 G3 Nodes Fails When Graphics Cards Are Present page 26 and the work around for the imaging process described in this section assumes that all nodes were discovered Follow this procedure to propagate the golden image to DL140 G3 and DL145 G3 servers containing a graphics card 1 Issue the appropriate startsys command and specify one of the DL140 G3 or DL145 G3 nodes with a graphics card in the nodelist option of the startsyscommand 2 When power to the node is turned on use the cluster console to connect to the node and force it to PXE boot by pressing the F12 key at the appropriate time during the BIOS start up 3 Whenthe node is successfully imaged repeat this process for the remaining nodes containing graphics cards 4 When all nodes containing graphics cards are imaged issue the start sys command without the nodelist option to image all remaining nodes of the cluster in parallel 5 5 Processing Time For cluster config Might Take Longer On A Head Node With Improved Availability 27 28 6 Software Upgrades This chapter contains notes about upgrading the HP XC System Software from a previous release to this release Installation release notes described in Chapter 4 page 23 and system configuration release notes describe
17. andards documents errata and archives of the MPI Forum The MPI Forum is an open group with representatives from many organizations that define and maintain the MPI standard http www unix mcs anl gov mpi A comprehensive site containing general information such as the specification and FAQs and pointers to other resources including tutorials implementations and other MPI related sites Related Information 11 12 Compiler Web Sites e http www intel com software products compilers index htm Web site for Intel compilers e http support intel com support performancetools Web site for general Intel software development information e http www pgroup com Home page for The Portland Group supplier of the PGI compiler Debugger Web Site http www etnus com Home page for Etnus Inc maker of the TotalView parallel debugger Software RAID Web Sites e http www tldp org HOWTO Software RAID HOWTO html and http wwwbiblio org pub Linux docs HOWTO other formats pdf Software RAID HOWTO pdf A document in two formats HTML and PDF that describes how to use software RAID under a Linux operating system e http www linuxdevcenter com pub a linux 2002 12 05 RAID html Provides information about how to use the mdadm RAID management utility Additional Publications For more information about standard Linux system administration or other related software topics consider using one of the follow
18. applies only to Cluster Platform 6000 systems 12 1 Network Boot Operation and Imaging Failures on HP Integrity rx2600 Systems An underlying issue in the kernel is causing MAC addresses on HP Integrity rx2600 systems to be set to all zeros for example 00 00 00 00 00 which results in network boot and imaging failures To work around this issue enter the following commands on the head node to network boot and image an rx2600 system 1 Prepare the node to network boot 4 setnode resync node name 2 Turn off power to the node stopsys hard node name 3 Start the imaging and boot process 4 startsys image and boot node name 12 2 Notes That Apply To The Management Processor 22 222 1223 This section describes limitations with the management processor MP that are expected to be resolved when a new firmware version is available Required Task Change MP Settings on Console Switches Perform this task before invoking the discover command In order for the discovery process to work correctly using the MP in DHCP mode you must increase the amount of time the console switches hold MAC addresses Increase this value from the default of 300 seconds to 1200 seconds Make this change only on the console switches in the system typically the ProCurve 26xx series From the ProCurve prompt enter the configuration mode and set the mac age t ime parameter as follows config config mac age time 1200 MP Disables DHC
19. are stack OFED is an open software stack supported by the major InfiniBand vendors as the future of InfiniBand support OFED offers improved support of multiple HCAs per node The OFED stack has a different structure and different commands from the InfiniBand stack that was used in previous HP XC releases See the following web page for more information about OFED http www openfabrics org The HP XC System Software Administration Guide provides OFED troubleshooting information 1 4 HP Scalable Visualization Array HP Scalable Visualization Array SVA software is now included on the HP XC System Software DVD distribution media SVA provides a comprehensive set of services for deployment of visualization applications allowing them to be conveniently run in a Linux clustering environment 1 1 Base Distribution and Kernel 15 The following are the key features of SVA e Capturing and managing visualization specific cluster information e Managing visualization resources and providing facilities for requesting and allocating resources for a job in a multi user multi session environment e Providing display surface configuration tools to allow easy configuration of multi panel displays Providing launch tools both generic and tailored to a specific application that launch applications with appropriate environments and display surface configurations Providing tools that extend serial applications to run in a clustered multi display
20. connect 45 K kernel version 15 Kickstart installation 23 L Linux operating system 15 LSF documentation 10 M management processor see MP manpages 12 mdadm utility 12 MP 41 MPI see HP MPI multiple rail support 35 Myrinet interconnect 45 N NC6170 NIC adapter 25 NC7170 NIC adapter 25 new features 15 NIC device driver mapping 25 O OFED 15 fork restrictions with HP MPI 35 51 OVP enhancements 17 P partition size limit 16 patches 19 Q qsnet diagnostics database 46 OsNet interconnect 45 R reporting documentation errors feedback e mail address for 13 resmon utility 17 S si updateclient utility 31 signal Quadrics OsNet 46 software RAID documentation 12 mdadm utility 12 SVA 15 system administration notes 31 system configuration 25 system management enhancements 17 notes 31 system monitoring 17 T temperature graph 17 U unified parallel C 17 UPC 17 upgrade 29 upgrade installation 29 W Web site HP XC System Software documentation 8 52 Index 53 O
21. d in Chapter 5 page 25 also apply when you upgrade the HP XC System Software from a previous release to this release Therefore when performing an upgrade make sure you also read and follow the instructions in those chapters 6 1 Do Not Upgrade If You Want Or Require The Voltaire InfiniBand Software Stack HP XC System Software Version 3 2 installs and uses the OFED InfiniBand software stack by default Previous HP XC releases installed the Voltaire InfiniBand software stack If you want to continue using the Voltaire InfiniBand software stack do not upgrade to HP XC System Software Version 3 2 6 1 Do Not Upgrade If You Want Or Require The Voltaire InfiniBand Software Stack 29 30 7 System Administration Management and Monitoring This chapter contains notes about system administration management and monitoring 7 1 Perform A Dry Run Before Using The si_updateclient Utility To Update Nodes Thesi updateclient utility can leave nodes in an unbootable state in certain situations You can still use si_updateclient to deploy image changes to nodes However before you update any nodes HP recommends that you perform a dry run first to ensure that files in the boot directory are not updated Updating files in boot can result in nodes being unable to boot You can retieve a list of files that will be updated by si updateclient by specifying dry run on the command line 7 2 Possible Problem With ext3 File Systems On SAN Storage
22. demark of Ethan Galstad The Portland Group and PGI are trademarks or registered trademarks of The Portland Group Compiler Technology STMicroelectronics Inc Quadrics and QsNet are registered trademarks of Quadrics Ltd Red Hat and RPM are registered trademarks of Red Hat Inc syslog ng is copyrighted by BalaBit IT Security Systemlmager is a registered trademark of Brian Finley TotalView is a registered trademark of Etnus Inc UNIX is a registered trademark of The Open Group Table of Contents About Thie A eier 7 Intended AUTE ts 7 Typographie CONEA AA AAN 7 HP XC and Related HP Products InNor mationen A i 8 Related loan nennen ee 9 Manpage M o O EEN Ee EAER KESERKEN EEE EEEE 12 HP Encourages Your ComMeEntS een een 13 1 New and Changed Features 15 1 1 Base Distribution and Kette ls 15 12 Support for Additional Hardware ModelS an est 15 1 3 OpenFabries Enterprise Distribution for ninia ina ve seine 15 1 4 HP Scalable Visualization Amaya een ne vensaneuacpetareatesuany 15 1 5 Partition Size Limits on Installation Disk suchen ne 16 1 6 More Flexibility in Customizing Client Node Disk Partitions ana a 16 1 7 Enhancements to the discover Command ee en 16 1 8 Enhancements to the cluster_config DITE sanan 16 1 9 System Management and Monitoring Enhancements suns ssec ore dunk cd 17 1 10 Enhancements to Te OVI sa 17 1 11 Installing and Upgrading HP XC System Software On Red Hat Enterprise Linux 17
23. desys lxc DESCRIPTION Running the preupgradesys lxc command is one of several commands that are part of the process to upgrade HP XC System Software on Red Hat Enterprise Linux to the next release of HP XC System Software on Red Hat Enterprise Linux The software upgrade process is documented in the HP XC System Software Installation Guide This command is never run for any reason other than during a software upgrade The preupgradesys lxc command prepares your system for a XC software upgrade by modifying release specific files recreating links where required and making backup copies of important files It also removes specific XC RPMs that do not upgrade properly Running preupgradesys Ixc is a required task before beginning a software upgrade The preupgradesys Ixc command does not prepare your system for upgrading Red Hat Enterprise Linux RPMs OPTIONS The preupgradesys lxc command does not have any options FILES var log preupgradesys lxc preupgradesys lxc log Contains command output and results SEE ALSO upgradesys lxc 8 HP XC System Software Installation Guide 15 2 4 New upgradesys Ixc 8 48 The upgradesys Ixc 8 manpage was not included in the HP XC Version 3 2 distribution upgradesys Ixc 8 NAME upgradesys Ixc For XC software upgrades this command upgrades and migrates configuration data to the new release format SYNOPSIS Path opt hptc Ixc upgrade sbin upgradesys lxc DESCRIPTION Running the upgradesys
24. e place to perform the task 5 3 Notes That Apply Before You Invoke The cluster config Utility Read the notes in this section before you invoke the cluster config utility 5 3 1 Adhere To Role Assignment Guidelines for Improved Availability When you are configuring services for improved availability you must adhere to the role assignment guidelines in Table 1 2 in the HP XC System Software Installation Guide Role assignments for a traditional HP XC system without improved availability of services is slightly different thus it is important that you follow the guidelines in Table 1 2 5 4 Benign Message From C52xcgraph During cluster config 26 You might see the following message when you run the cluster config utility on a cluster with an InfiniBand interconnect Executing C52xcgraph gconfigure Found no adapter info on IRONOO Failed to find any Infiniband ports Executing C54httpd gconfigure System Discovery Configuration and Imaging This message is displayed because the C52xcgraph configuration script is probing the InfiniBand switch to determine how many HCAs with an IP address are present Because the HCAs have not yet been assigned an IP address C52xcgraph does not find any HCAs with an IP address and prints the message This message does not prevent the cluster config utility from completing To work around this issue after the cluster is installed and configured run opt hptc hpcgraph sbin hpcgraph setup with no options
25. er Blades and Enclosures Edition 9 HowTo was merged into the HP XC Hardware Preparation Guide and HP XC System Software Installation Guide reducing the number of documents you have to read to install and configure an HP XC system that contains HP server blades and enclosures e The HP XC System Software Release Notes are updated periodically Therefore HP recommends that you go to http www docs hp com en linuxhpc html and make sure you have the latest version of this document because the version you are reading now might have been updated since the last time you downloaded it HP XC HowTos On the Worldwide Web HP XC information that is published between releases is issued in HowTo documents at the following Web site http www docs hp com en linuxhpc html 18 New and Changed Features 2 Important Release Information This chapter contains information that is important to know for this release 2 1 Firmware Versions The HP XC System Software is tested against specific minimum firmware versions Follow the instructions in the accompanying hardware documentation to ensure that all hardware components are installed with the latest firmware version The master firmware tables for this release are available at the following Web site http www docs hp com en linuxhpc html The master firmware tables list the minimum firmware versions on which the Version 3 2 HP XC System Software has been qualified At a minimum the HP XC s
26. escribes how to customize client node disk partitions is documented in the HP XC System Software Installation Guide 17 Enhancements to the discover Command The following options were added to the discover command e The nodesonly option reads in the database and discover all nodes if the hardware configuration contains HP server blades and enclosures This option is valid only when the enclosurebased option is also used e The nothreads option runs the node discovery process without threads if the hardware configuration contains HP server blades and enclosures This option is valid only when the enclosurebased option is also used 1 8 Enhancements to the cluster config Utility The cluster config utility prompts you to specify whether you want to configure the Linux virtual server LVS director to act as a real server that is a node that accepts login sessions If you answer yes the LVS director is configured to act as a login session server in addition to arbitrating and dispersing the login session connections If you answer no the LVS director does not participate as a login session server its only function is to arbitrate and disperse login sessions to other nodes This gives you the flexibility to place 16 New and Changed Features the Login role on the head node yet keep the head node load to a minimum because login sessions are not being spawned This configuration choice is documented in the HP XC System Softwa
27. g at the same time The problem usually affects multiple enclosures The work around for this problem is to completely power cycle the entire cluster or at least all enclosures after the initial cluster installation is complete or if the problem is encountered This problem has never been reported after the power has been cycled and the cluster is in its normal running state This problem is targeted for resolution in iLO2 firmware Version 1 28 but at the time of publication had not been tested yet 13 1 iLO2 Devices In Server Blades Can Hang 43 14 Interconnects This chapter contains information that applies to the supported interconnect types e InfiniBand Interconnect page 45 e Myrinet Interconnect page 45 QsNetl Interconnect page 45 14 1 InfiniBand Interconnect The notes in this section apply to the InfiniBand interconnect 14 1 1 enable Password Problem With Voltaire Switch Version 4 1 The instructions for configuring Voltaire InfiniBand switch controller cards requires you to change the factory default passwords for the admin and enable accounts as follows Insert new up to 8 characters Enter password An issue exists where you must enter a password with exactly eight characters for the enable account The admin account is not affected If the new password does not contain exactly eight characters the following message appears when you try to log in with the new password Unauthorized mode fo
28. ing publications which must be purchased separately e Linux Administration Unleashed by Thomas Schenk et al e Linux Administration Handbook by Evi Nemeth Garth Snyder Trent R Hein et al e Managing NFS and NIS by Hal Stern Mike Eisler and Ricardo Labiaga O Reilly e MySQL by Paul Debois MySQL Cookbook by Paul Debois e High Performance MySQL by Jeremy Zawodny and Derek J Balling O Reilly e Perl Cookbook Second Edition by Tom Christiansen and Nathan Torkington e Perlin A Nutshell A Desktop Quick Reference by Ellen Siever et al Manpages Manpages provide online reference and command information from the command line Manpages are supplied with the HP XC system for standard HP XC components Linux user commands LSF commands and other software components that are distributed with the HP XC system Manpages for third party software components might be provided as a part of the deliverables for that component Using discover 8 as an example you can use either one of the following commands to display a manpage man discover man 8 discover If you are not sure about a command you need to use enter the man command with the k option to obtain a list of commands that are related to a keyword For example man k keyword HP Encourages Your Comments HP encourages comments concerning this document We are committed to providing documentation that meets your needs Send any errors found suggestions for impro
29. n on the system and for general users who log in to the system to run jobs The information in this document assumes that you have knowledge of the Linux operating system Typographic Conventions This document uses the following typographical conventions or A percent sign represents the C shell system prompt A dollar sign represents the system prompt for the Korn POSIX and Bourne shells A number sign represents the superuser prompt audit 5 A manpage The manpage name is audit and it is located in Section 5 Command A command name or qualified command phrase Computer output Text displayed by the computer Ctri x A key sequence A sequence such as Ctrl x indicates that you must hold down the key labeled Ctrl while you press another key or mouse button ENVIRONMENT VARIABLE The name of an environment variable for example PATH ERROR NAME The name of an error usually returned in the errno variable Key The name of a keyboard key Return and Enter both refer to the same key Term The defined use of an important word or phrase User input Commands and other text that you type Intended Audience 7 Variable The name of a placeholder in acommand function or other syntax display that you replace with an actual value The contents are optional in syntax If the contents are a list separated by you can choose one of the items The contents are required in syntax If the contents are a list separated
30. nables you to modify the device configuration information in the HP XC command and management database CMDB Uses for this command include configuring a range of default external network interface cards NICs across multiple nodes and configuring one or two additional external NICs on the same node 15 2 2 Changes to ovp 8 Note the following two changes to the ovp 8 manpage 1 Under o options opts_for_test options add the following before user username queue LSF queue Specifies the LSF queue for the performance health tests 2 Change the following portion of the v component verify component as follows OLD For all users This option takes the form verify perf health test cpu Tests CPU core performance using the Linpack benchmark NEW For all users This option takes the form verify perf health test NOTE Except for the network stress and network bidirectional tests these tests only apply to systems that install LSF HPC incorporated with SLURM The network stress and network bidirectional tests also function under Standard LSF cpu Tests CPU core performance using the Linpack benchmark 15 2 3 New preupgradesys Ixc 8 The preupgradesys Ixc 8 manpage was not included in the HP XC Version 3 2 distribution 15 1 Documentation CD Search Option 47 preupgradesys Ixc 8 NAME preupgradesys Ixc Prepares a system for an XC software upgrade SYNOPSIS Path opt hptc Ixc upgrade sbin preupgra
31. ng interface Supermon works in conjunction with Nagios to provide HP XC system monitoring http www llnl gov linux pdsh Home page for the parallel distributed shell pdsh which executes commands across HP XC client nodes in parallel http www balabit com products syslog_ng Home page for syslog ng a logging tool that replaces the traditional syslog functionality The syslog ng tool is a flexible and scalable audit trail processing tool It provides a centralized securely stored log of all devices on the network http systemimager or Home page for SystemImager which is the underlying technology that distributes the golden image to all nodes and distributes configuration changes throughout the system http linuxvirtualserver org Home page for the Linux Virtual Server LVS the load balancer running on the Linux operating system that distributes login requests on the HP XC system http www macrovision com Home page for Macrovision developer of the FLEXIm license management utility which is used for HP XC license management http sourceforge net projects modules Web site for Modules which provide for easy dynamic modification of a user s environment through modulefiles which typically instruct the module command to alter or set shell environment variables http dev mysql com Home page for MySQL AB developer of the MySQL database This Web site contains a link to the MySQL documentation
32. particularly the documentation relating to the LSF HPC integration with SLURM supersedes the information supplied in the LSF manuals from Platform Computing Corporation The Platform Computing Corporation LSF manpages are installed by default Isf_diff 7 supplied by HP describes LSF command differences when using LSF HPC with SLURM on an HP XC system The following documents in the HP XC System Software Documentation Set provide information about administering and using LSF on an HP XC system HP XC System Software Administration Guide HP XC System Software User s Guide http www linl gov LCdocs slurm Documentation for the Simple Linux Utility for Resource Management SLURM which is integrated with LSF to manage job and compute resources on an HP XC system http www nagios or Home page for Nagios a system and network monitoring application that is integrated into an HP XC system to provide monitoring capabilities Nagios watches specified hosts and services and issues alerts when problems occur and when problems are resolved http oss oetiker ch rrdtool Home page of RRDtool a round robin database tool and graphing system In the HP XC system RRDtool is used with Nagios to provide a graphical view of system status http supermon sourceforge net Home page for Supermon a high speed cluster monitoring system that emphasizes low perturbation high sampling rates and an extensible data protocol and programmi
33. products that are integrated into the HP XC System Software core technology In the HP XC documentation except where necessary references to third party and open source software components are generic and the HP XC adjective is not added to any reference to a third party or open source command or product name For example the SLURM srun command is simply referred to as the srun command The location of each Web site or link to a particular topic listed in this section is subject to change without notice by the site provider e http www platform com Home page for Platform Computing Corporation the developer of the Load Sharing Facility LSF LSF HPC with SLURM the batch system resource manager used on an HP XC system is tightly integrated with the HP XC and SLURM software Documentation specific to LSF HPC with SLURM is provided in the HP XC documentation set Related Information 9 10 Standard LSF is also available as an alternative resource management system instead of LSF HPC with SLURM for HP XC This is the version of LSF that is widely discussed on the Platform Web site For your convenience the following Platform Computing Corporation LSF documents are shipped on the HP XC documentation CD in PDF format Administering Platform LSF Administration Primer Platform LSF Reference Quick Reference Card Running Jobs with Platform LSF LSF procedures and information supplied in the HP XC documentation
34. qsnet mysql gt delete from switch modules where name QRON03 mysql quit service swm restart In addition to the previous problem the IP address of a switch module might be incorrectly populated in the switch modules table and you might see the following message qsctrl qsctrl failed to parse module name 172 20 66 2 Resolve this issue by deleting the IP address from the switch modules table and restarting the swmlogger service mysql u root p qsnet mysgl delete from switch modules where name 172 20 66 2 mysql gt quit service swm restart NOTE You must repeat the previous procedure if you invoke the cluster config utility again and you choose to re create the qsnet database during the cluster config operation Interconnects 15 Documentation This chapter describes known issues with the HP XC documentation 15 1 Documentation CD Search Option If you are viewing the main page of the HP XC Documentation CD you cannot perform a literature search from the Search option box at the top of the page To search http www docs hp com or to search all of HP s global Web service click on the link for More options The Advanced search options page is displayed and you can perform the search from the advanced page 15 2 HP XC Manpages 15 2 The notes in this section apply to the HP XC manpages New device config 8 A manpage is available for the device config command The device config command e
35. r this user wrong password or illegal mode in the first word This problem has been reported to Voltaire As a work around choose a password that is exactly eight characters 14 2 Myrinet Interconnect The following release notes are specific to the Myrinet interconnect 14 2 1 Myrinet Monitoring Line Card Can Become Unresponsive A Myrinet monitoring line card can become unresponsive some period of time after it has been set up with an IP address with DHCP This is a problem known to Myricom For more information see the following http www myri com fom serve cache 321 html If the line card becomes unresponsive re seat the line card by sliding it out of its chassis slot and then slide it back in You can do this while the system is up doing so does not interfere with Myrinet traffic 14 2 2 The clear_counters Command Does Not Work On The 256 Port Switch The opt gm sbin clear counters command does not clear the counters on the Myrinet 256 port switch The web interface to the Myrinet 256 port switch has changed from the earlier smaller switches To clear the switch counters you must open an interactive Web connection to the switch and clear the counters using the menu commands The gm prodmode mon script which uses the clear counters command will not clear the counters periodically as it does on the smaller switches This problem will be resolved in a future software update from Myricom 14 3 QsNet Interconnect The
36. re Installation Guide 1 9 System Management and Monitoring Enhancements System management and monitoring utilities have been enhanced as follows e Anew resource monitoring tool resmon has been added resmon is a job centric resource monitoring Web page initially inspired by the open source clumon product resmon invokes useful commands to collect and present data in a scalable and intuitive fashion The resmon Web pages update automatically at a preconfigured interval 120 seconds by default See resmon 1 for more information The HP Graph Web interface has been enhanced to include a cpu temperature graph To access this new graph select temperature from the Metrics pull down menu at the top of the Web page 1 10 Enhancements to the OVP The operation verification program OVP performance health tests were updated to accept an option to specify an LSF queue In addition you can run two performance health tests network_stressandnetwork_bidirectional on systems that are configured with standard LSF or configured with LSF HPC with SLURM 1 11 Installing and Upgrading HP XC System Software On Red Hat Enterprise Linux The HP XC System Software Installation Guide contains two new chapters that describes the following topics Installing HP XC System Software Version 3 2 on Red Hat Enterprise Linux Upgrading HP XC System Software Version 3 1 on Red Hat Enterprise Linux to HP XC System Software Version 3 2 on Red Hat Enterpri
37. s 19 20 3 Hardware Preparation Hardware preparation tasks are documented in the HP XC Hardware Preparation Guide This chapter contains information that was not included in that document at the time of publication 3 1 Upgrading BMC Firmware On HP ProLiant DL140 G2 and DL145 C2 Nodes This note applies only if the hardware configuration contains HP ProLiant DL140 G2 or DL145 G2 nodes and you are upgrading an existing HP XC system from Version 2 1 or Version 3 0 to Version 3 2 The HP ProLiant DL140 G2 G2 and DL145 G2 series of hardware models must be installed with BMC firmware version 1 25 or greater However the BMC version 1 25 firmware was not supported by HP XC Version 3 0 or earlier As a result you must update the BMC firmware on these nodes after you upgrade the system to HP XC Version 3 2 which is contrary to the upgrade instructions for a typical upgrade Before upgrading an HP XC system to Version 3 2 contact the HP XC Support Team and request the procedure to upgrade the BMC firmware on HP ProLiant DL140 G2 and DL145 G2 nodes xc supportQGhp com 3 1 Upgrading BMC Firmware On HP ProLiant DL140 G2 and DL145 G2 Nodes 21 22 4 Software Installation On The Head Node This chapter contains notes that apply to the HP XC System Software Kickstart installation session 4 1 Manual Installation Required For NC510F Driver The unm nic driver is provided with the HP XC software distribution however it does not load
38. se Linux 1 12 Support For HP Unified Parallel C This release provides support for the HP Unified Parallel C UPC application development environment HP UTC is a parallel extension of the C programming language which runs on both common types of multiprocessor systems those with a common global address space such as SMP and those with distributed memory UPC provides a simple shared memory model for parallel programming allowing data to be shared or distributed among a number of communicating processors Constructs are provided in the language to permit simple declaration of shared data distribute shared data across threads and synchronize access to shared data across threads This model promises significantly easier coding of parallel applications and maximum performance across shared memory distributed memory and hybrid systems See the following Web page for more information about HP UPC http www hp com go upc 1 9 System Management and Monitoring Enhancements 17 1 13 Documentation Changes The following changes were made to the HP XC System Software Documentation Set e The following manuals have been affected by the new functionality delivered in this release and have been revised accordingly HP XC Hardware Preparation Guide HP XC System Software Installation Guide HP XC System Software Administration Guide HP XC System Software User s Guide e The information in the Configuring HP XC Systems With HP Serv
39. se cards 1 2 3 0 e rank2 will use cards 2 3 0 1 e rank4 will use cards 3 0 1 2 The order is important in SRO mode because only the first card is used for short messages The selection approach allows short RDMA messages to use all the cards in a balanced way For HP MPI 2 2 5 1 and older all cards must be on the same fabric 9 3 Benign Messages From HP MPI Version 2 2 5 1 When running jobs with XC Version 3 2 OFED InfiniBand and HP MPI Version 2 2 5 1 the following messages are printed once for each rank libibverbs Warning fork safety requested but init failed HP MPI Version 2 2 5 1 has support for fork using OFED 1 2 but only for kernels more recent than version 2 6 12 HP XC Version 3 2 is currently based on kernel version 2 6 9 This message is a reminder that fork is not supported in this release You can suppress this message by defining the MPI IBV NO FORK _SAFE environment variable as follows opt hpmpi bin mpirun np 4 prot e MPI IBV NO FORK SAFE 1 hostlist nodea nodeb nodec noded my dir hello world 9 1 MPI and OFED InfiniBand Stack Fork Restrictions 35 36 10 Cluster Platform 3000 At the time of publication no release notes are specific to Cluster Platform 3000 systems 37 38 11 Cluster Platform 4000 At the time of publication no release notes are specific to Cluster Platform 4000 systems 39 40 12 Cluster Platform 6000 This chapter contains information that
40. ss beginning with the cluster_prep command 5 2 Notes That Apply To The Discover Process The notes in this section apply to the discover utility 5 2 1 Discovery of HP ProLiant DL140 G3 and DL145 G3 Nodes Fails When Graphics Cards Are Present When an HP ProLiant DL140 G3 or DL145 G3 node contains a graphics card the nodes often fail to PXE boot Even when the BIOS boot settings are configured to include a PXE boot these settings are often reset to the factory defaults when the BIOS restarts after saving the changes This action causes the discovery and imaging processes to fail Follow this procedure to work around the discovery failure 1 Begin the discovery process as usual by issuing the appropriate discover command 2 When the discovery process turns on power to the nodes of the cluster manually turn off the DL140 G3 and DL145 G3 servers that contain graphics cards 3 Manually turn on power to each DL140 G3 and DL145 G3 server one at a time and use the cluster s console to force each node to PXE boot Do this by pressing the F12 key at the appropriate time during the BIOS start up After you complete this task for each DL140 G3 and DL145 G3 server containing a graphics card the discovery process continues and completes successfully The work around for the imaging failure on these servers is described in HP ProLiant DL140 G3 and DL145 G3 Node Imaging Fails When Graphics Cards Are Present page 27 which is the appropriat
41. tere nnet Rc 45 14 1 1 enable Password Problem With Voltaire Switch Version 4 1 sse 45 14 2 M y riter Intereonneck ee ine tns dono ebenen 45 14 2 1 Myrinet Monitoring Line Card Can Become Unresponsive sse 45 14 2 2 The clear counters Command Does Not Work On The 256 Port Switch 45 14 3 QsNet Intereonnect een PU tue etri mitis e E E eir eus 45 14 3 1 Possible Conflict With Use of SIGLISR2 nei fi Dr RR dE 46 14 3 2 The qsnet Database Might Contain Entries To Nonexistent Switch Modules 46 A A M p NER 47 15 1 Docasnentaton CD Search ODEDB nennen ii id 47 15 2 HAP dE iu un 47 112 1 New device COPIE AMA nn 47 15 22 Cha ang s OO 0 0 MN i n 47 4 Table of Contents TS 23 New preupgradesys a AMA E O O 47 15 24 New aperadesys Dusa anne nn 48 Table of Contents 5 About This Document This document contains release notes for HP XC System Software Version 3 2 This document contains important information about firmware software or hardware that might affect the system An HP XC system is integrated with several open source software components Some open source software components are being used for underlying technology and their deployment is transparent Some open source software components require user level documentation specific to HP XC systems and that kind of information is included in this doc
42. the mapping if a re ordering has occurred At the time of the Kickstart installation the fiber ports are identified as ethO and eth1 and the onboard ports are identified as eth2 and eth3 The etc modprobe conf file is written as follows e alias eth0 e1000 e alias ethl e1000 e alias eth2 tg3 e alias eth3 tg3 You must correct this mapping if you find that upon the HP XC kernel reboot eth0 and eth1 are the tg3 devices and eth2 and eth3 are the e1000 devices To get the external network connection working perform this procedure from a locally connected terminal before invoking the cluster_prep utility 1 Unload the tg3 and e1000 drivers rmmod e1000 rmmod tg3 2 Use the text editor of your choice to edit the etc modprobe conf file to correct the mapping of drivers to devices The section of this file should look like this when you are finished alias eth0 tg3 alias ethl tg3 alias eth2 e1000 alias eth3 e1000 3 Save your changes and exit the text editor 4 Use the text editor of your choice to edit the etc sysconfig network scripts ifcfg eth 0 1 2 3 files and remove the HWADDR line from each file if it is present 5 If you made changes save your changes and exit each file 6 Reload the modules 5 1 Notes That Apply Before You Invoke The cluster prep Utility 25 modprobe tg3 modprobe e1000 7 Follow the instructions in the HP XC System Software Installation Guide to complete the cluster configuration proce
43. ument when required HP relies on the documentation provided by the open source developers to supply the information you need to use their product For links to open source software documentation for products that are integrated with the HP XC system see Supplementary Software Products page 9 Documentation for third party hardware and software components that are supported on the HP XC system is supplied by the third party vendor However information about the operation of third party software is included in this document if the functionality of the third party component differs from standard behavior when used in the XC environment In this case HP XC documentation supersedes information supplied by the third party vendor For links to related third party Web sites see Supplementary Software Products page 9 Standard Linux administrative tasks or the functions provided by standard Linux tools and commands are documented in commercially available Linux reference manuals and on various Web sites For more information about obtaining documentation for standard Linux administrative tasks and associated topics see the list of Web sites and additional publications provided in Related Software Products and Additional Publications page 11 Intended Audience The release notes are intended for anyone who installs and configures an HP XC system for system administrators who maintain the system for programmers who write applications to ru
44. vement or compliments to feedback fc hp com Include the document title manufacturing part number and any comment error found or suggestion for improvement you have concerning this document HP Encourages Your Comments 13 14 1 New and Changed Features This chapter describes the new and changed features delivered in HP XC System Software Version 3 2 1 1 Base Distribution and Kernel The following table lists information about the base distribution and kernel for this release as compared to the last HP XC release HP XC Version 3 2 HP XC Version 3 1 Enterprise Linux 4 Update 4 Enterprise Linux 4 Update 3 HP XC kernel version 2 6 9 42 9hp XC HP XC kernel version 2 6 9 34 7hp XC Based on Red Hat kernel version 2 6 9 42 0 8 EL Based on Red Hat kernel version 2 6 9 34 0 2 EL 1 2 Support for Additional Hardware Models In this release the following additional hardware models and hardware components are supported in an HP XC hardware configuration e HP ProLiant servers HP ProLiant DL360 G5 HP ProLiant DL380 G5 HP ProLiant DL580 G4 HPProLiant DL145 G3 HP ProLiant DL385 G2 HP ProLiant DL585 G2 HP Integrity servers and workstations HP Integrity rx2660 HP Integrity rx4640 HP xw9400 workstation 1 3 OpenFabrics Enterprise Distribution for InfiniBand Starting with this release the HP XC System Software uses the OpenFabrics Enterprise Distribution OFED InfiniBand softw
45. witch connections HP XC System Software Installation Guide Provides step by step instructions for installing the HP XC System Software on the head node and configuring the system HP XC System Software Administration Guide Provides an overview of the HP XC system administrative environment cluster administration tasks node maintenance tasks LSF administration tasks and troubleshooting procedures HP XC System Software User s Guide Provides an overview of managing the HP XC user environment with modules managing jobs with LSF and describes how to build run debug and troubleshoot serial and parallel applications on an HP XC system QuickSpecs for HP XC System Software Provides a product overview hardware requirements software requirements software licensing information ordering information and information about commercially available software that has been qualified to interoperate with the HP XC System Software The QuickSpecs are located on line http www hp com go clusters See the following sources for information about related HP products HP XC Program Development Environment The Program Development Environment home page provide pointers to tools that have been tested in the HP XC program development environment for example TotalView and other debuggers compilers and so on http h20311 www2 hp com HPC cache 276321 0 0 0 121 html HP Message Passing Interface HP Message Passing Interface HP MP
46. ystem components must be installed with these versions of the firmware Read the following guidelines before upgrading the firmware on any component in the hardware configuration e Never downgrade to an older version of firmware unless you are specifically instructed to do so by the HP XC Support Team e The master firmware tables clearly indicate newer versions of the firmware that are known to be incompatible with the HP XC software Incompatible versions are highlighted in bold font Do not install these known incompatible firmware versions because unexpected system behavior might occur e There is always the possibility that a regression in functionality is introduced in a firmware version It is possible that the regression could cause anomalies in HP XC operation Report regressions in HP XC operation that result from firmware upgrades to the HP XC Support Team xc supportGhp com e Contact the HP XC Support Team if you are not sure what to do regarding firmware versions 2 2 Patches Software patches might be available for this release Because network connectivity is not established during a new installation until the cluster prep utility has finished preparing the system you are instructed to download the patches when you reach that point in the installation and configuration process The HP XC System Software Installation Guide provides more information about where to access and download software patches 2 1 Firmware Version