Home
HP NC7770 User's Manual
Contents
1. VCCI VCCI 4A PCI X Notice When this product is used in PCI X mode it is a Class A device HP NC7770 PCI X Gigabit Server Adapter User Guide A 5 Electrostatic Discharge Overview To prevent damage to the system be aware of the precautions you need to follow when setting up the system or handling parts A discharge of static electricity from a finger or other conductor may damage system boards or other static sensitive devices This type of damage may reduce the life expectancy of the device To prevent electrostatic damage observe the following precautions e Avoid hand contact by transporting and storing products in static safe containers e Keep electrostatic sensitive parts in their containers until they arrive at static free workstations e Place containers on a grounded surface before removing the contents e Avoid touching
2. NC7770 PCI X Gigabit Server Adapter Figure 1 1 RJ 45 port and LED locations HP NC7770 PCI X Gigabit Server Adapter User Guide 1 1 Introduction LED Indicators The following table describes the LED indicators located on the front panel of the HP NC7770 Server Adapter Table 1 1 10 100 1000 LED Operations for the NC7770 Adapter LED Display Description 1000 On Link to the adapter is established The adapter is sending or receiving network data at 1000 Mb s Off The adapter is not sending or receiving network data at 1000 Mb s 100 On Link to the adapter is established The adapter is sending or receiving network data at 100 Mb s Off The adapter is not sending or receiving network data at 100 Mb s 10 On Link to the adapter is established The adapter is sending or receiving network data at 10 Mb s Off The adapter is not sending or receiving network data at 10 Mb s ACT On The adapter is sending or receiving network data at 10 100 or 1000 Mb s as indicated by the 10 100 and 1000 LEDs The adapter is receiving power and the cable connection is functional Off No network data is being sent or received The adapter is not receiving power the cable connection is faulty or the driver is not loaded UTP Category 5 Cable The NC7770 Server Adapter can use existing Category 5 UTP or better cable to deliver Gigabit Ethernet over copper according to the IEEE 802 3ab specifications For new installation
3. if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures e Reorient or relocate the receiving antenna e Increase the separation between the equipment and receiver e Connect the equipment into an outlet on a circuit different from that to which the receiver is connected e Consult the dealer or an experienced radio or television technician for help Modifications Cables The FCC requires the user to be notified that any changes or modifications made to this device that are not expressly approved by Hewlett Packard Company may void the user s authority to operate the equipment Connections to this device must be made with shielded cables with metallic RF EMI connector hoods in order to maintain compliance with FCC Rules and Regulations Declaration of Conformity for products marked with the FCC logo United States only This device complies with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 this device may not cause harmful interference and 2 this device must accept any interference received including i
4. Requirement Operating Voltage 5V 5 Power Consumption 10 Watts Maximum 2A 5V DC Standards Supported IEEE 802 3ab 802 3u 802 1p 802 1z Dimensions 6 6 x 2 5 inches L x W 16 5 cm x 6 4 cm Connector and distances 10BASE T Category 3 4 or 5 UTP 100 Meters 328 feet 100BASE TX Category 5 UTP 100 Meters 328 feet 1000BASE TX Category 5 UTP 100 Meters 328 feet Interrupts Supported Automatically configured Temperature Range Operating 0 C to 55 C 32 F to 131 F Storage 65 C to 85 C 85 F to 185 F Relative Humidity Operating 596 to 8596 Storage 596 to 9596 Emissions Classifications When used in PCI slot FCC Class B When used in PCI X slot FCC Class A European Classifications EN 55022 CISPR 22 EN 50082 1 IEC 801 2 IEC 801 3 IEC 801 4 VCCI Safety Compliance CE Mark EN 60590 HP NC7770 PCI X Gigabit Server Adapter User Guide C 1 Specifications UTP Cable Specifications To connect to the network the NC7770 Server Adapter uses the following cable for 1000BASE T transmission Category 5 UTP or better 22 26 AWG 1000 1MHz EIA TIA 568a or EIA TIA 568b Using UTP Category 5 Cable in Gigabit Over Copper Installations For Gigabit over copper installations Category 5 UTP or better 1000BASE T cable must comply with the IEEE 802 3ab 1000B ASE T standard For new installations Category 5e enhanced Category 5 or better cable i
5. Category 5 Cable nee sert ette t e I EL 1 2 Chapter 2 Installing the Adapter CVE VIEW iecit eel RE ES SA A ee EE Se SR A AL AR Te 2 1 Electrostatic Discharge Precautions sens 2 1 Installing the Adapter ma Server nimes oh ipo e e d ce decer eie torte rm 2 2 Connecting th Network Cable 53 nie et Ree ee dee sebo este D EET HE eee teinture idee 2 3 Appendix A Regulatory Notice Federal Communications Commissions Notice ss A 1 Glass A Equipment srl TEAK EOE UOI E EE A 1 Class B Equipment eeno Ek eter ee E tpe e e ne ud A 2 Modificatli OSE A 2 DS A 2 Canadian Notice Avis Canadien lt lt lt A 3 Class A Equipment dece deae EE A 3 Class B Equipment 2 1p n tee ete tee i Pe ge E HER EL EIER ts A 3 European Umion Notice 0 A 4 BSMI NOCE Sairaan ei EE RE A eea Aarie En GE A 4 Japanese NotICe sour supe iste EE nl ER Hein tb EU etre Dese Meee aca tetas A 5 PGI X NOUCe 5 31 idee lee oe eee a iude due do eese e ipe dee EE A 5 Appendix B Electrostatic Discharge OVerVIew c cue edt E oet Relay ea e ill B 1 Groundimng Methods redi ee p b et tee qu EE B 1 HP NC7770 PCI X Gigabit Server Adapter User Guide lii Contents Appendix C Specifications NC7770 PCI X Gigabit Server Adapter Specifications C 1 UTP Cable Specifications enr ento Pee edge toto tetto Haee Pri
6. Green White BI_DB 6 7 BI_DD White Brown BI_DD 7 8 BI_DD Brown White BI_DD 8 Figure C 3 shows straight through Gigabit over copper connector wiring to be used when the crossover function is implemented within the hub or switch White Orange Orange yhite White Green BlueA nite White Blue GreenA hite Vhite Brown Brown V hite Figure C 3 Gigabit straight through wiring for RJ 45 connector D 7 Cn Ch 4 UN Gigabit over Copper External Crossover Pinouts When a crossover function is not provided by the adapter hub or switch you must implement it through the twisted pair media using the physical pinouts shown in Table C 5 C 4 HP NC7770 PCI X Gigabit Server Adapter User Guide Specifications Table C 5 Gigabit over Copper Crossover Pinouts Pin Function Color Match Function Pin 1 BI_DA White Orange BI_DB 3 2 BI_DA Orange White BI_DB 6 3 BI_DB White Green BI_DA 1 4 BI_DC Blue White BI_DD 7 5 BI_DC White Blue BI_DD 8 6 BI_DB Green White BI_DA 2 7 BI_DD White Brown BI_DC 4 8 BI_DD Brown White BI_DC 5 Figure C 4 shows the correct Gigabit over copper wiring to be used when the crossover function is implemented externally in the twisted pair cabling D 7 Cn Ch 4 CO l2 White Orange Orange yhite White Green BlueA hite White Blue GreenANhite Vhite Brown BrowntAhite Figure C 4 Gigabit over copper external crossover for RJ 45 connector HP NC7770 PCI X Gigabit Se
7. HP NC7770 PCI X Gigabit Server Adapter User Guide June 2007 Second Edition Part Number 336419 00B 2003 2007 Hewlett Packard Development Company L P Broadcom is a registered trademark of Broadcom Corporation and or its subsidiaries Hewlett Packard Company shall not be liable for technical or editorial errors or omissions contained herein The information in this document is provided as is without warranty of any kind and is subject to change without notice The warranties for HP products are set forth in the express limited warranty statements accompanying such products Nothing herein should be construed as constituting an additional warranty Confidential computer software Valid license from HP required for possession use or copying Consistent with FAR 12 211 and 12 212 Commercial Computer Software Computer Software Documentation and Technical Data for Commercial Items are licensed to the U S Government under vendor s standard commercial license HP NC7770 PCI X Gigabit Server Adapter User Guide June 2007 Second Edition Part Number 336419 00B HP Contents About This Guide Technician Notes RERO ENERO OE La dtt detenta V Where to Go for Additional PO 01012 vi Telephone Numbers sise des coz nt ses es e n ee mete cep ci ere dir ettet vi Chapter 1 Introduction OVerVIeW au m eto C RR eene 1 1 Hardware Overview x iiem egeris EE 1 1 LED Andicators 4 iin ned eut BRI o COE de SIE aret eO RD DE RE ere 1 2 UTP
8. h the twisted pair media using the physical pinouts indicated in Table C 3 Table C 3 10 100 Pinouts Using External Crossover Pin Function Color Match Function Pin 1 TD White Orange RD 2 TD Orange White RD 3 RD White Green TD 1 4 Blue White 5 White Blue 6 RD Green White TD 2 7 White Brown 8 Brown White Figure C 2 shows the correct wiring to use when the crossover function is implemented externally in the twisted pair cabling White Orange Orange hite White Green GreenAMWhite Figure C 2 10 100 external crossover for RJ 45 connector HP NC7770 PCI X Gigabit Server Adapter User Guide C 3 Specifications Gigabit over Copper Internal Straight Through Pinouts Unlike connections in which the crossover function is implemented internally at the hub or switch the NC7770 Server Adapter provides its own automatic crossover function This means you can wire twisted pair media straight through for adapter to hub adapter to switch or adapter to adapter connections using the pinouts shown in Table C 4 NOTE To operate at Gigabit speeds all four pairs of wires must be terminated within the RJ 45 connector Table C 4 Gigabit over Copper Pinouts Using Internal Crossover Pin Function Color Match Function Pin 1 BI_DA White Orange BI_DA 1 2 BI_DA Orange White BI_DA 2 3 BI_DB White Green BI_DB 3 4 BI_DC Blue White BI_DC 4 5 BI_DC White Blue BI_DC 5 6 BI_DB
9. he device as well as additional operating instructions for the user The rating label on the device shows which class A or B the equipment falls into Class B devices have an FCC logo or FCC ID on the label Class A devices do not have an FCC logo or FCC ID on the label Once the class of the device is determined refer to the following corresponding statement Class A Equipment This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at personal expense HP NC7770 PCI X Gigabit Server Adapter User Guide A 1 Regulatory Notice Class B Equipment This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and
10. is product has telecommunication functionality the R amp TTE Directive 1999 5 EC Compliance with these directives implies conformity to the following European Norms in parentheses are the equivalent international standards and regulations e EN 55022 CISPR 22 Electromagnetic Interference e EN55024 IEC61000 4 2 3 4 5 6 8 11 Electromagnetic Immunity e EN61000 3 2 IEC61000 3 2 Power Line Harmonics e EN61000 3 3 IEC61000 3 3 Power Line Flicker e EN 60950 IEC 60950 Product Safety BSMI Notice E nr BEIM fu D gt EHAE REKA HP NC7770 PCI X Gigabit Server Adapter User Guide Regulatory Notice Japanese Notice Cr VCCD B
11. ity of the individual boards and subassemblies do not attempt to make repairs at the component level or to make modifications to any printed wiring board Improper repairs can create conditions that are hazardous WARNING To reduce the risk of electric shock or damage to the equipment e Disconnect power from the system by unplugging all power cords from the power supplies e Do not disable the power cord grounding plug The grounding plug is an important safety feature e Plug the power cord into a grounded earthed electrical outlet that is easily accessible at all times CAUTION To properly ventilate the system you must provide at least 7 6 cm 3 0 in of clearance at the front and back of the server CAUTION The computer is designed to be electrically grounded earthed To ensure proper operation plug the AC power cord into a properly grounded AC outlet only HP NC7770 PCI X Gigabit Server Adapter User Guide About This Guide NOTE Any indications of component replacement or printed wiring board modifications may void any warranty Where to Go for Additional Help HP updates networking software frequently to include new functionality and features Complete the following steps to get the latest drivers firmware and documentation 1 Goto the HP website http www hp com 2 Click Support and Troubleshooting Information from the left menu bar 3 Type the product name in the for produc
12. nt electrostatic damage observe the following precautions e Always properly ground yourself when touching a static sensitive component or assembly e Avoid hand contact by transporting and storing parts in static safe containers e Keep electrostatic sensitive parts in their containers until they arrive at static free locations e Place containers on a grounded surface before removing the contents e Avoid touching pins leads or circuitry HP NC7770 PCI X Gigabit Server Adapter User Guide 2 1 Installing the Adapter Installing the Adapter in a Server Refer to the HP ProLiant server documentation for additional information on how to safely install a PCI card in your server c0 I Figure 2 1 Installing the adapter in a server PCI Slot WARNING If the server is not PCI Hot Plug compliant power it down and unplug the power cord from the power outlet before removing the server cover Failure to do so may damage the adapter or server l Remove the server cover and cover bracket from a PCI slot WARNING To reduce the risk of personal injury from hot surfaces allow the internal system components to cool before touching them 2 Firmly seat the adapter in the PCI slot and secure the adapter bracket 3 Replace the server cover and plug in the power cord 2 2 HP NC7770 PCI X Gigabit Server Ada
13. nter e toL Levi RE PEL PE Le Dots C 2 Using UTP Category 5 Cable in Gigabit Over Copper Installations C 2 RJ 45 Pinouts and Crossover Function EE C 2 10 100 Straight Through Pinouts ss C 2 OO 100 CTO8SSOVeFP1nOUS ki C 3 Gigabit over Copper Internal Straight Through Pinouts eese C 4 Gigabit over Copper External Crossover Pinouts eese enne nennen nennen C 4 iv HP NC7770 PCI X Gigabit Server Adapter User Guide About This Guide Use this guide as reference when installing and maintaining the HP NC7770 PCI X Gigabit Server Adapter WARNING To reduce the risk of personal injury from electric shock and hazardous energy levels only authorized service technicians should attempt to repair this equipment Improper repairs can create conditions that are hazardous Technician Notes AN WARNING Only authorized technicians trained by HP should attempt to repair this equipment All troubleshooting and repair procedures are detailed to allow only subassembly module level repair Because of the complexity of the individual boards and subassemblies no one should attempt to make repairs at the component level or to make modifications to any printed wiring board Improper repairs can create a safety hazard AN WARNING To reduce the risk of personal injury from electric shock and hazardous energy levels do not exceed the level of repairs specified in these procedures Because of the complex
14. nterference that may cause undesired operation For questions regarding your product contact Hewlett Packard Company P O Box 692000 Mail Stop 530113 Houston Texas 77269 2000 Or call 1 800 652 6672 For continuous quality improvement calls may be recorded or monitored HP NC7770 PCI X Gigabit Server Adapter User Guide Regulatory Notice For questions regarding this FCC declaration contact Hewlett Packard Company P O Box 692000 Mail Stop 510101 Houston Texas 77269 2000 Or call 281 514 3333 To identify this product refer to the Part Series or Model number found on the product Canadian Notice Avis Canadien Class A Equipment This Class A digital apparatus meets all requirements of the Canadian Interference Causing Equipment Regulations Cet appareil num rique de la classe A respecte toutes les exigences du R glement sur le mat riel brouilleur du Canada Class B Equipment This Class B digital apparatus meets all requirements of the Canadian Interference Causing Equipment Regulations Cet appareil num rique de la classe B respecte toutes les exigences du R glement sur le mat riel brouilleur du Canada HP NC7770 PCI X Gigabit Server Adapter User Guide A 3 Regulatory Notice European Union Notice CE Products bearing the CE marking comply with the EMC Directive 89 336 EEC and the Low Voltage Directive 73 23 EEC issued by the Commission of the European Community and if th
15. pins leads or circuitry e Always be properly grounded when touching a static sensitive component or assembly Grounding Methods There are several methods for grounding Use one or more of the following methods when handling or installing electrostatic sensitive parts e Usea wrist strap connected by a ground cord to a grounded workstation or computer chassis Wrist straps are flexible straps with a minimum of 1 megohm 10 percent resistance in the ground cords To provide proper ground wear the strap snug against the skin e Use heel straps toe straps or boot straps at standing workstations Wear the straps on both feet when standing on conductive floors or dissipating floor mats e Use conductive field service tools e Use a portable field service kit with a folding static dissipating work mat If you do not have any of the suggested equipment for proper grounding have a HP authorized reseller install the part NOTE For more information on static electricity or assistance with product installation contact your HP authorized reseller HP NC7770 PCI X Gigabit Server Adapter User Guide B 1 C Specifications NC7770 PCI X Gigabit Server Adapter Specifications Table C 1 NC7770 PCI X Gigabit Server Adapter Specifications Specification Network Controller Chipset Description Broadcom 5701KHB Data Transfer Method 64 bit 1 33MHz PCI X compatible with 64 bit 66MHz or 32 bit 66MHz Bus Master DMA Power
16. pter User Guide Installing the Adapter Connecting the Network Cable Network connections for the NC7770 Server Adapter can employ existing Category 5 UTP or better cable for Gigabit over copper transmissions For new installations Category 5e enhanced Category 5 or better cable is recommended To secure the cable plug the cable connector into the RJ 45 port Ensure that the tab on the plug clicks into position indicating that it is properly seated For more information see UTP Cable Specifications in Appendix C HP NC7770 PCI X Gigabit Server Adapter User Guide 2 3 A Regulatory Notice Federal Communications Commissions Notice Part 15 of the Federal Communications Commission FCC Rules and Regulations has established Radio Frequency RF emission limits to provide an interference free radio frequency spectrum Many electronic devices including computers generate RF energy incidental to their intended function and are therefore covered by these rules These rules place computers and related peripheral devices into two classes A and B depending upon their intended installation Class A devices are those that may reasonably be expected to be installed in a business or commercial environment Class B devices are those that may reasonably be expected to be installed in a residential environment 1 e personal computers The FCC requires devices in both classes to bear a label indicating the interference potential of t
17. rver Adapter User Guide
18. s Category 5e cable is recommended For troubleshooting and other information about cabling see UTP Cable Specifications in Appendix C 1 2 HP NC7770 PCI X Gigabit Server Adapter User Guide 2 Installing the Adapter Overview This chapter describes installation precautions and explains how to install the adapter It also describes how to connect the network cable the safety information and user documentation provided with your equipment before i WARNING To avoid the risk of personal injury or damage to the equipment consult attempting installation of the adapter Many servers are capable of producing energy levels that are considered hazardous Users should not remove enclosures nor should they bypass the interlocks provided for removal of these hazardous conditions Installation of this adapter should be performed by individuals who are both qualified in the servicing of computer equipment and trained in the hazards associated with products capable of producing hazardous energy levels NOTE Before removing the cover of your server refer to the HP documentation for the proper methods for installing a PCI card and avoiding electric shock hazards Electrostatic Discharge Precautions A discharge of static electricity from a finger or other conductor can damage components on the adapter This can make the adapter inoperable In addition to the following information see Appendix B for more precautions To preve
19. s recommended RJ 45 Pinouts and Crossover Function The Ethernet standard also specifies that each segment implement a crossover function to connect the transmitter of one device to the receiver of a device at the other end and vice versa The crossover function may be implemented internally at the hub or switch or externally through the twisted pair media 10 100 Straight Through Pinouts If the crossover function is implemented internally the port is labeled MDI X Medium Dependent Interface Crossover When an MDI X port is connected to an MDI port the twisted pair media should be wired straight through using the physical pinouts indicated in Table C 2 Table C 2 10 100 Pinouts Using Internal Straight Through Crossover Pin Function Color Match Function Pin 1 TD White Orange TD 1 2 TD Orange White TD 2 3 RD White Green RD 3 4 Blue White 4 5 White Blue 5 6 RD Green White RD 6 7 White Brown 7 8 Brown White 8 Figure C 1 shows the straight through 10 100 connector wiring to be used when the crossover function is implemented on the hub or switch C 2 HP NC7770 PCI X Gigabit Server Adapter User Guide Specifications 1 White Orange 2 OrandgeA hite 3 White Green 4 5 B GreenMWhite 7 8 Figure C 1 10 100 straight through wiring for RJ 45 connector 10 100 Crossover Pinouts When the crossover function is not provided within the hub or switch you must implement the crossover throug
20. t box and press Enter For example type NC370T 4 Download the drivers firmware or documentation as needed Telephone Numbers For the name of your nearest HP authorized reseller e Inthe United States call 1 800 345 1518 e In Canada call 1 800 263 5868 For HP technical support e Inthe United States and Canada call 1 800 652 6672 e Outside the United States and Canada refer to www hp com vi HP NC7770 PCI X Gigabit Server Adapter User Guide d Introduction Overview The HP NC7770 PCI X Gigabit Server Adapter is a high performance Ethernet adapter with a fully integrated 10 100 1000 controller that delivers up to 1000 Mb s Ethernet over twisted pair copper cabling The HP NC7770 adapter has one auto negotiating RJ 45 port and LED indicators showing link activity and port speed The NC7770 PCI X Gigabit Server Adapter is a supported option for selected HP ProLiant servers For the latest functionality features and operating system support for this server adapter refer to the networking page at http h18004 www1 hp com products servers networking index nic html Hardware Overview The NC7770 Server Adapter has one auto negotiating 10 100 1000 RJ 45 port LED indicators show link activity and port speed See Table 1 1 for descriptions of LED operations M E AFO Dn uto 1000 Mivs LED nd 000 7 100 Mais Leo lt 10 Mis LED Ti Activity LED un N be k 3 J