Home

HP FC1242SR User's Manual

image

Contents

1. VCCI VCCI A Korean notice FC1142SR and FC1242SR DC 4Gb PCI Express host bus adapters for Linux and Windows installation guide 33 Safety Electrostatic discharge To prevent damage to the system be aware of the precautions you need to follow when setting up the system or handling parts A discharge of static electricity from a finger or other conductor may damage system boards or other staticsensitive devices This type of damage may reduce the life expectancy of the device Preventing electrostatic damage To prevent electrostatic damage observe the following precautions Avoid ha
2. Scan Fibre Channel Devices This option scans the Fibre Channel loop and lists all connected devices by loop ID Information about each device is listed such as the vendor name product name and revision This information is useful when configuring the HBA and connected devices Fibre Disk Utility This option scans the Fibre Channel loop and lists all connected devices by loop ID You can select a hard disk and perform a low level format or verify the hard disk A CAUTION Performing a low level format destroys all data on the hard disk Loopback Data Test This option lets you perform a loopback test Ensure that the Fibre Channel loop is up or that a loopback plug is connected to the HBA before starting the test Select Host Adapter If your system has multiple HBAs use this option to select and then configure or view the settings for an HBA 30 Configuring the HBAs B Regulatory compliance and safety Laser device All HP systems equipped with a laser device comply with safety standards including International Electrotechnical Commission IEC 825 With specific regard to the laser the equipment complies with laser product performance standards set by government agencies as a Class 1 laser product The product does not emit hazardous light Laser safety warning A WARNING To reduce the risk of exposure to hazardous radiation Do not try to open the laser device enclosure There are no userserviceable compo
3. Event Viewer 23 SCSIPORT miniport driver 16 Storport miniport driver 16
4. The default is Yes Enable Target Reset Enables drivers to issue a Target Reset command to all devices on the loop when a SCSI Bus Reset command is issued The default is No Login Retry Count The number of times the software tries to log in to a device The default is 8 Port Down Retry Count The number of times the software issues a command to a port returning port down status The default is 16 retries Link Down Timeout The number of seconds the software waits for a link to come up or go down Values for this setting are 0 255 seconds The default is 8 Operation Mode Specifies the reduced interrupt operation RIO mode if supported by the driver The RIO mode allows multiple command completions in a single interrupt The modes are 0 Inlerrupt for every I O completion default 5 Interrupt when Interrupt Delay timer expires 6 Interrupt when Interrupt Delay timer expires or there is no active O Interrupt Delay Timer The wait time in 200 microsecond increments used by the timer to set the wait time between interrupts Values for this setting are 0 255 seconds The default is 0 Default Settings This option restores the HBA default settings Raw NVRAM Data This option displays the HBA s NVRAM contents in hexadecimal format This is a troubleshooting tool you cannot modify the data FC1142SR and FC1242SR DC 4Gb PCI Express host bus adapters for Linux and Windows installation guide 29
5. zip file that contains the installation program Click Open to extract the driver software installation program immediately Click Save to save the zip file containing the HP Smart Component executable to your system and run the installation at a later time Extract the HP Smart Component executable to your computer Double click the HP Smart Component executable cp00xxxx exe file to start the installation Click Install to install the driver software 10 Click Reboot to complete the installation 16 Installing the Windows drivers Installing the Linux drivers This chapter describes how to install the Linux qla2300 device drivers for the FC1142SR HBA and FC1242SR DC HBA on an installed Red Hat Enterprise Linux RHEL system or on a SUSE Linux Enterprise Server SUSE SLES system You can obtain the software kit for the driver from the following HP web site http h18006 www 1 hp com storage saninfrastructure html To install the drivers you must be familiar with the operating system on which the HBA is to operate and have access to standard system documentation Use the procedures and information in the following sections Installing the driver kit page 18 Using the fibreutils RPM page 19 FC1142SR and FC1242SR DC 4Gb PCI Express host bus adapters for Linux and Windows installation guide 17 Installing the driver kit HP recommends that you install the complete driver kit for the FC1142SR_ and FC1143SR
6. 2 Installing the HBAs This chapter describes how to install the FC1142SR and FC1242SR DC HBAs Installation prerequisites page 14 e Installation procedure page 14 See your host documentation for installation instructions A WARNING Disconnect the host from the power source before installing the HBA To reduce the risk of personal injury from hot surfaces allow the internal server or workstation components to cool before touching A WARNING Electrostatic discharge ESD can damage electronic components Before you begin ensure that you are properly grounded as described in Electrostatic discharge on page 34 FC1142SR and FC1242SR DC 4Gb PCI Express host bus adapters for Linux and Windows installation guide 13 Installation prerequisites Before you begin ensure that You have an optical multimode cable with an LC duplex connector You record the HBA s serial number in the unlikely event that the NVRAM is corrupted Each HBA has a unique serial number located on the bottom of the HBA Installation procedure 14 To install the HBA 1 Check the motherboard and make any necessary configuration changes to accommodate the HBA OR NO MR WN Turn off the computer Disconnect the power cable 10 Plug in the power cable Open and remove the computer cover and save the screws Locate the slot in which you will install the HBA and remove the slot cover Place the HBA in the slot an
7. Computer and select Manage 2 Click Event Viewer in the Computer Management dialog box The Event Viewer window appears 3 Review the miniport driver event codes See the following web site for information about interpreting the event codes htto www qlogic com support logs evlogV9xxx_error asp Linux driver events If the Linux driver detects any fabric or driver events the information is written to in the var 1og messages file Check this file periodically to review fabric or Linux driver events FC1142SR and FC1242SR DC 4Gb PCI Express host bus adapters for Linux and Windows installation guide 23 24 Troubleshooting A Configuring the HBAs This appendix provides detailed configuration information for advanced users who want to customize the configuration of the HBAs and connected devices A CAUTION Ifthe configuration settings are incorrect the HBA may not function properly This appendix describes the following Fast UTIL options e Running Fast UTIL page 26 Configuration Settings page 26 Scan Fibre Channel Devices page 30 Fibre Disk Utility page 31 Loopback Data Test page 30 Select Host Adapter page 30 FC1142SR and FC1242SR DC 4Gb PCI Express host bus adapters for Linux and Windows installation guide 25 Running Fast UTIL You configure the HBAs using Fast UTIL HP s BIOS resident configuration tool To run Fast UTIL 1 Press ALT Q during HBA BIOS initialization it may take a
8. De 19 Changing driver parameters 19 Loading and unloading the qla2300 driver manually 1 2 2 2 0 00 ee 19 oe cis PIERA RFC AER rro 21 Troubleshooting checklists US RNN SN 22 Hardware checklist oa saaara tek Ba oa a td 22 System configuration checklist ocios e a a 22 Fibre Channel checklists AN aN Re Rees Re et 22 Using the Event Viewer caos dha aa aa A oad eas os pda 23 nn a eae Re ese el ae S 23 A Configuring the HBAs j46640 2 nb ed id dao td edad 25 Running hast 4 se ees ae yey ae hee ade SF HES TENG a PHOS Tale as a 26 Configuration Settings a dle pe ida Oink WA ORR a Ad nm eRe a 26 FC1142SR and FC1242SR DC 4Gb PCI Express host bus adapters for Linux and Windows installation guide 3 Adapter Settings i 26 Selectable Boot Settings i 27 Advanced Adapter Settings i 28 Restore Default Settings SO 29 Raw NVRAM Dao 29 Scan Fibre Channel Devices cy dl RANA NASA AAA AAA 30 Fibre DUI rr SO Ac 30 loopback Data Test SS 30 Select Host Adapter A A A edi 30 B Regulatory compliance and safety 31 laser device NNW A Rem E 2 31 Laser safety WHINING edicts Radda aS RaERG NN aR D EWE Ae Bawa RAS ww 31 Certification and classification information 31 Laser product label tardas aa ENS PRED EE SORE Shwe eRe 31 Inter
9. HBAs The kit contains the driver and utilities you need to deploy HBAs on Linux NOTE You must install the gcc compiler and the kernel sources or the kernel development package on your system before installing the driver kit To install the complete driver kit copy the gz file to your system and enter the following commands gunzip hp_qla2300version_info tar gz tar xvf hp_qla2300version_info tar cd hp_qla2300 INSTALL See the README file included with the driver kit for more information Using the RPM to install drivers The RPM Package Manager RPM is a package management system that facilitates the installation of Linux software Using RPM you can install software in prebuilt bundles called RPM packages The driver RPM packages have the driver source code and driver utilities Ef NOTE This section is provided as a reference for future RPM installations Installing the RPM To install the RPM copy the RPM package file to your system and enter the following command rpm ivh package_name rpm For example to install the Linux HBA driver RPM manually enter the following command rpm ivh hp_qla2300 version rpm Upgrading the RPM To upgrade the RPM copy the RPM package file to your system and enter the following command rom Uvh package_name rpm Uninstalling the RPM To uninstall the RPM enter the following command rpm e package_name 18 Installing the Linux drivers Using th
10. Novel business FC1142SR and FC1242SR DC 4Gb PCI Express host bus adapters for Linux and Windows installation guide Contents PO MAA 5 Intended audience i os odio rias EE ER ER oS bet de 5 Related documentation Li 5 Document conventions and symbols nnna annaa 6 HP technical support oeoa A Gaus patie ad eons 7 Subscription service rica id aiii 7 Helpful web sites A eRe Ea ed ee 7 NARS stn ethos seein ES ES 9 Performance specifications cane neces saad an anee Kaede ee ON 10 Environmental specifications iai 04 ae sae aa yee kaya de ae te RY NAK Me Rake Ga 10 Physical specifications NR sw Ged cm ese NR ae oh PC eWEEK me ae 11 2 Installing he HBAS sar DABA A id NAAA 13 Installation prerequisites sa 14 Installation procedure AA O O aA area 14 A RNN SD E a a Ea a APR Es 14 3 Installing the Windows drivers gt order 13 Installation prerequisites oy 16 Installing the Windows device drivers using the HP Smart Component kit 16 A Installing Ma UE 17 Installing eCiverkilos sseievoterddedads tecGde ces PS A Ed Re 18 Using the RPM to install drivers o dc A A iS 18 Installing the RPM esos cig oe ias e dak ois ba aint ane te pal 18 Upgradingithe RIM saaie bebe tee bees o aed i a E bead Died BESS 18 Uninstalling the RPM LL 18 Using the fibreutils RPM SI SR a Ned a as Hsin Ge wal oh Wed a a Heh
11. few seconds for the FasHUTIL Options menu to display 2 If you have more than one HBA Fast UTIL asks you to select the HBA you want to configure 3 Change the settings and exit the utility Fast UTIL reboots the system to load the new parameters Configuration Settings Use Configuration Settings to configure the Fibre Channel devices and the HBA to which they connect Adapter Settings From the Configuration Settings menu in Fast UTIL select Adapter Settings Table 5 lists the default settings for the HBA Table 5 Adapter Settings Setting Values Default Host Adapter BIOS Enabled Disabled Disabled Loop Reset Delay 0 60 seconds 5 seconds Adapter Hard Loop ID Enabled Disabled Disabled Hard Loop ID 0 125 0 Spin Up Deloy Enabled Disabled Disabled Connection Options O 1 2 Fibre Channel Tape Support Enabled Disabled Enabled Data Rate 0 1 2 3 26 Configuring the HBAs A description of each setting follows Host Adapter BIOS When this setting is disabled the ROM BIOS on the HBA is disabled freeing space in upper memory This setting must be enabled if you are booting from an Fibre Channel hard disk connected to the HBA The default is Disabled Frame Size Specifies the maximum frame length supported by the HBA The default 2048 provides maximum performance for F_Port point to point connections Loop Reset Delay After resetting the loop the firmware refrains from initiating any lo
12. regulatory compliance notice 32 C certification and classification information laser 31 Class A equipment Canadian compliance statement 32 configuring HBAs 26 conventions document 6 text symbols 6 D document conventions 6 documentation HP web site 5 drivers changing parameters on Linux 19 installing from RPM 18 installing Windows 16 manually loading on Linux 19 qla2300 17 troubleshooting 23 E electrostatic damage prevention 34 environmental specifications 10 ESD electrostatic discharge 34 European Union regulatory compliance notice 32 event log 23 Event Viewer using 23 F Fast UTIL Adapter Settings 26 Advanced Adapter Settings 28 configuring HBAs 26 Fibre Disk Utility 30 Raw NVRAM Data 29 Restore Default Settings 29 Scan Fibre Channel Devices 30 Select Host Adapter 30 fibreutils RPM 19 G gcc compiler 18 German noise declaration 34 grounding methods 34 H HBAs configuring 26 environmental specifications 10 installation prerequisites 14 performance specifications 10 physical specifications 11 help obtaining 7 HP storage web site Subscriber s choice web site 7 technical support 7 IEC EMC worldwide regulatory compliance notice 32 installing Linux drivers 18 prerequisites for HBAs 14 RPM 18 Windows drivers 16 J Japan regulatory compliance notice 33 K Korean regulatory compliance notice 33 FC1142SR and FC1242SR DC 4Gb PCI Express host bus adapters for L
13. HP StorageWorks FC1142SR and FC1242SR DC 4Gb PCI Express host bus adapters for Linux and Windows installation guide Legal and notice information Copyright 2005 Hewlett Packard Development Company L P Hewlett Packard Company makes no warranty of any kind with regard to this material including but not limited to the implied warranties of merchantability and fitness for a particular purpose Hewlett Packard shall not be liable for errors contained herein or for incidental or consequential damages in connection with the furnishing performance or use of this material This document contains proprietary information which is protected by copyright No part of this document may be photocopied reproduced or translated into another language without the prior written consent of Hewlett Packard The information is provided as is without warranty of any kind and is subject to change without notice The only warranties for HP products and services are set forth in the express warranty statements accompanying such products and services Nothing herein should be construed as constituting an additional warranty HP shall not be liable for technical or editorial errors or omissions contained herein Linux is a U S registered trademark of Linus Torvalds Microsoft and Windows are U S registered trademarks of Microsoft Corporation Red Hat is a U S registered trademark of Red Hat Inc SUSE is a trademark of SUSE LINUX Products GmbH a
14. anced Adapter Settings Setting Options Default Execution Throttle 1 256 16 Luns per Target 0 8 16 32 64 128 256 128 Enable LIP Reset Yes No No Enable LIP Full Login Yes No Yes Enable Target Reset Yes No Yes Login Retry Count 0 255 8 Port Down Retry Count 0 255 16 Link Down Timeout 0 255 8 28 Configuring the HBAs Table 6 Advanced Adapter Settings continued Setting Options Default Operation Mode 0 5 6 0 Interrupt Delay Timer 0 255 0 A descriptions of each setting follows Restore Execution Throttle The maximum number of commands executing on one port When a port s execution throttle value is reached no new commands are executed until the current command finishes executing Values for this setting are 1 256 The default is 16 Luns per Target The number of LUNs per target Multiple LUN support is typically for RAID arrays that use LUNs to map drives The default is 128 If you do not need multiple LUN support set the number of LUNs to 0 Enable LIP Reset The type of loop initialization process LIP reset used when the operating system initiates a bus reset routine When this setting is Yes the driver initiates a global LIP reset to clear the target device reservations When this setting is No the driver initiates a global LIP reset with full login The default is No Enable LIP Full Login Instructs the ISP chip to log in to all ports after LIP
15. d FC1242SR DC 4 Gb PCI Express host bus adapters for Linux and Windows release notes from the following HP web site http h18006 www 1 hp com storage saninfrastructure html Obtain the HP Smart Component kit with the latest drivers from the following HP web site http h18006 www 1 hp com storage saninfrastructure html Familiarize yourself with the operating system on which the HBA will operate and obtain standard system documentation Review any restrictions or mandatory hot fixes that apply to your configuration and operating system Installing the Windows device drivers using the HP Smart Component kit This section describes how to install the Windows SCSIPORT miniport and Storport minipor drivers To install the latest SCSIPORT or Storport driver you must use the HP Smart Component kit EY NOTE HP does not support Device Manager to update drivers Using Device Manager can delete registry parameters and cause erratic behavior ab WwW DN 7 8 9 Select the FC1142SR or FC1242SR DC HBA from the Fibre Channel Host Bus Adapters list on the SAN infrastructure web page described in Installation prerequisites The web page for the HBA appears Click Software and drivers Select a language from the drop down list Select a Windows operating system In the Driver Storage Controllers FC HBA section click Download in the row for either the SCSIPORT or Storport driver component Open or save
16. d press carefully until it is seated properly Secure the HBA to the chassis following the server manufacturer s instructions Connect the appropriate cable from the devices to the corresponding LC connector Close the computer cover Insert and tighten the computer cover screws Tl Turn on the computer and observe the monitor and the LED indicators to ensure proper operation see LED indicators on page 14 LED indicators Table 4 describes the LED indicators Table 4 LED indicators Yellow LED Green LED Amber LED Activity Off Off Off Power off On On On Power on before or after firmware initialization Flashing Flashing Flashing Power on after firmware initialization Alternately flashing Alternately flashing Alternately flashing Firmware fault Off Off Flashing Activity at 1 Gb s Off Flashing Off Activity at 2 Gb s Flashing Off Off Activity at 4 Gb s Flashing Off Flashing Beacon Installing the HBAs Installing the Windows drivers This chapter describes how to install the Windows SCSIPORT miniport driver and Storport miniport driver e Installation prerequisites page 16 e Installing the Windows device drivers using the HP Smart Component kit page 16 FC1142SR and FC1242SR DC 4Gb PCI Express host bus adapters for Linux and Windows installation guide 15 Installation prerequisites Before you install the Windows drivers Obtain the HP StorageWorks FC1142SR an
17. dows operating systems HBAs Related documentation In addition to this guide see the HP StorageWorks FC 11425R and FC1242SR DC 4Gb PCI Express host bus adapters for Linux and Windows release notes These and other HP documents are available on the HP web site http www docs hp com FC1142SR and FC1242SR DC 4Gb PCI Express host bus adapters for Linux and Windows installation guide 5 Document conventions and symbols Table 1 Document conventions Convention Element Medium blue text Figure 1 Cross reference links and e mail addresses Medium blue underlined text http www hp com Web site addresses Bold font Key names e Text typed into a GUI element such as into a box GUI elements that are clicked or selected such as menu and list items buttons and check boxes Italics font Text emphasis Monospace font Monospace italic font e File and directory names System output Code Text typed at the command line Code variables Command line variables Monospace bold font Emphasis of file and directory names system output code and text typed at the command line A WARNING Indicates that failure to follow directions could result in bodily harm or death A CAUTION Indicates that failure to follow directions could result in damage to equipment or data E IMPORTANT Provides clarifying information or specific instructions EX NOTE Provides add
18. e fibreutils RPM HP recommends using the fibreutils RPM that is included with the driver kit It contains useful utilities for managing fibre connected storage To install this RPM manually enter the following command rpm ivh fibreutils version rpm For more information about fibreutils see the file opt hp hp_fibreutils README Changing driver parameters To change driver parameters 1 Run the set_parm script located in the opt hp src directory 2 Reboot the server otherwise you may not be able to unload the qla2300 driver if there is a process or file system using a device connected to the HBA Loading and unloading the qla2300 driver manually By loading the qla2300 driver manually you can access the devices and unload the driver without rebooting the system To load the qla2300 driver enter the following command modprobe ala2300 EY NOTE HP recommends using the modprobe command to load the driver so that any driver parameter value specified in the etc modules conf file takes effect Alternatively you can load the driver by entering the following command from the directory that contains the qla2300 0 file 1 Enter the insmod command For example insmod qla2300 0 2 If your system has a previous version of the qla driver rename the old binary included in the original distribution to ensure that it does not interfere with the new version as follows cd lib modules kernel_releas
19. e_version kernel drivers addon qla2300 mv qla2300 0 qla2300_rh o 3 After renaming the old driver update the dependency file then load the new driver using the modprobe command 4 To unload the qla2300 driver manually enter the command as shown in the following example modprobe r qla2300 FC1142SR and FC1242SR DC 4Gb PCI Express host bus adapters for Linux and Windows installation guide 19 20 Installing the Linux drivers 5 Troubleshooting This chapter provides troubleshooting information that you can use in the event of an HBA problem Troubleshooting checklists page 22 Using the Event Viewer page 23 Linux driver events page 23 FC1142SR and FC1242SR DC 4Gb PCI Express host bus adapters for Linux and Windows installation guide 21 Troubleshooting checklists Three basic types of installation problems can cause HBAs to malfunction hardware problems system configuration problems and Fibre Channel problems This section provides checklists to help you determine why the HBA is not functioning properly Hardware checklist Check the following Are circuit cards installed securely in the system Are cables connected securely to the correct connectors For example the optical transmit connector on the HBA must be connected to the optical receive connector on the device An easy way to check for correct seating is to switch the connectors on the HBA or the device then reboot your system If the BIOS is
20. el Bus type fiber optic media Bus transfer rate FC1142SR single channel 4 Gb s Fibre Channel increases aggregate throughput rate to 800 MB s in full duplex mode FC1242SR DC dual channel 4 Gb s Fibre Channel increases aggregate throughput rate to 1 6 GB s in full duplex mode Central processing unit CPU Single chip design that includes a RISC processor Fibre Channel protocol manager PCl e DMA controller integrated serializer deserializer SERDES and electrical transceivers that can auto negotiate a data rate of 1 2 or 4 Gb s Memory 1 MB SRAM 1 MB flash SPI and 2 KB NVRAM SPI Signal voltage 3 3 V mode 1 3 3 V 1 5 V mode 2 Distance 1 Gb s 500 meters 50 125 um fiber 300 meters 62 5 125 um fiber 2 Gb s 300 meters 50 125 um fiber 150 meters 62 5 125 um fiber 4 Gb s 150 meters 50 125 um fiber 70 meters 62 5 125 um fiber Cable 50 125um multimode fiber 62 5 125 um multimode fiber Connectors LC connectors that support non OFC multimode fiber optic cabling using a SFF optical transceiver module Form factor Low profile PCle 16 765 cm x 6 89 cm 6 6 in x 2 713 in Bracket Standard 1 84 cm x 12 08 cm 73 in x 4 76 in Low profile 1 84 cm x 8 01 cm 73 in x 3 15 in Power consumption 11 0 watts FC1142SR and FC1242SR DC 4Gb PCI Express host bus adapters for Linux and Windows installation guide 11 12 HBA features
21. enabled devices connected to the HBA are displayed on the screen Is the HBA installed correctly and seated firmly in the PCle slot ls there interference due to nonstandard PCle connectors ls the Fast UTIL data rate setting correct See Adapter Settings on page 26 for information about setting the data rate System configuration checklist Check the following Is the motherboard properly connected Did you check the motherboard for proper configuration All PCl compliant and PCI X compliant systems automatically detect 32 bit or 64 bit adapters and set the appropriate bus speed for example 33 MHz or 133 MHz See the documentation for your computer or contact your computer dealer to determine if the motherboard requires special configuration Fibre Channel checklist Check the following 22 Did you power up the Fibre Channel devices before powering up the server Are cables connected properly Did you configure the RAID controller using the utilities provided by the manufacturer If the Fibre Channel switch supports zoning is the switch configured correctly Troubleshooting Using the Event Viewer The SCSIPORT and Storport miniport drivers verify the HBA s power on self test POST LED states If there is a failure or a suspected failure an error log entry is written to the Windows event log To view the event log 1 Select Start gt Programs gt Administrative Tools gt Event Viewer or right click My
22. ent sur le mat riel brouilleur du Canada European Union notice Products bearing the CE marking comply with the EMC Directive 89 336 EEC and the Low Voltage Directive 73 23 EEC issued by the Commission of the European Community and if this product has telecommunication functionality the R amp TTE Directive 1999 5 EC Compliance with these directives implies conformity to the following European Norms in parentheses are the equivalent international standards and regulations EN55022 CISPR 22 Electromagnetic Interference e EN55024 IEC61000 4 2 IEC61000 4 3 IEC61000 4 4 IEC61000 4 5 IEC61000 4 6 IEC61000 4 8 IEC61000 4 11 Electromagnetic Immunity Power Quality e EN61000 3 2 IEC61000 32 Power Line Harmonics EN61000 3 3 IEC61000 3 3 Power Line Flicker EN60950 IEC60950 Product Safety Also approved under UL 60950 CSA C22 2 No 60950 00 Safety of Information Technology Equipment BSMI notice 32 De AAR Ade gt Al Ae Bis A Fie isl gt KAAS AREER ERAN ES HST e Regulatory compliance and safety Japanese notice VCCI VCCI B
23. evices FC1142SR and FC1242SR DC 4Gb PCI Express host bus adapters for Linux and Windows installation guide 27 You can select the boot device as follows Enable Selectable Boot Boot WWPN LUN list Boot device N A xxx appears Not specified Specified To enable the Selectable Boot option BIOS configures the first disk drive it finds as the boot device BIOS configures the first disk drive it finds that is LUN 0 as the boot device BIOS scans the specified WWPN and LUN list until it finds a disk drive This drive is configured as the boot device 1 From the Configuration Settings menu select Adapter Settings 2 Enable the HBA BIOS and then press ESC to return to the Configuration Settings menu Use the menu as follows Use the arrow keys to select Selectable Boot Settings Press ENTER to enable or disable toggle the Selectable Boot option 3 Move to the primary location of the Selectable Boot List menu 4 Press ENTER to view a list of accessible devices these are the devices in the Select Fibre Channel Device menu 5 Using the arrow keys to select the device you want to add to the Selectable Boot List menu Press ENTER to select the device Repeat step 5 to specify up to three alternate boot devices Advanced Adapter Settings From the Configuration Settings menu in Fast UTIL select Advanced Adapter Settings Table 6 lists the default settings for the HBA Table 6 Adv
24. iated with system at 2 5 Gb s Support for VCO 1 Virtual Channel and TCO 1 Traffic Class e Configuration O memory read write completion and message support Support for 64 bit addressing ECRC for all transmitted PCle data packets Link CRC on all PCle packets and message information Support for large payload size 2048 bytes for read write Support for large read request size 4096 bytes Internal high speed static RAM SRAM Error correcting code ECC protection of local memory including single bit correction and double bit protection Small form factor SFF multimode optic with LC connector Parts and construction compliant to the European Union Directive of Restriction of Hazardous Substances RoHS Environmental specifications Table 2 lists the environmental specifications Table 2 HBA environmental specifications Environmental feature Minimum Maximum Operating temperature 0 C 32 F 55 C 131 F Storage temperature 20 C 4 F 70 C 158 F Relative humidity non condensing 10 90 Storage humidity non condensing 5 95 10 HBA features Physical specifications Table 3 lists the physical specifications Table 3 HBA physical specifications Component Specification Host bus Complies with PCI Express Base Specification 1 0a PCI Express Card Electromechanical Specification 1 0 PCI Bus Power Management Interface Specification 1 1 Fibre Chann
25. inux and Windows installation guide 35 L label laser 31 laser international certification and classification information 31 product label 31 radiation warning 31 Linux gz file 18 changing driver parameters 19 fibreutils RPM 19 gcc compiler 18 installing drivers 18 manually loading drivers 19 RPM 18 set_parm script 19 troubleshooting 23 log event 23 N noise declaration German 34 P parameters Linux drivers 19 performance specifications 10 power on self test POST 23 preventing electrostatic damage 34 problems configuration 22 Fibre Channel 22 hardware 22 Q qla2300 drivers 17 R regulatory compliance notices BSMI 32 European Union 32 IEC EMC statement worldwide 32 Japan 33 Korean 33 RPM fibreutils 19 installing 18 36 uninstalling 18 upgrading 18 S SCSIPORT miniport drivers installing 16 troubleshooting 23 set_parm script 19 specifications environmental 10 performance 10 physical 11 Storport miniport drivers installing 16 troubleshooting 23 Subscriber s choice HP 7 symbols in text 6 T technical support HP 7 text symbols 6 troubleshooting configuration problems 22 event log 23 Fibre Channel problems 22 hardware problems 22 Linux 23 Windows Event Viewer 23 U uninstalling the RPM 18 upgrading the RPM 18 W warnings lasers radiation 31 web sites HP documentation 5 HP storage 7 HP Subscriber s choice 7 Windows drivers installing 15 event log 23
26. itional information o TIP Provides helpful hints and shortcuts HP technical support Telephone numbers for worldwide technical support are listed on the HP web site http www hp com support Collect the following information before calling Technical support registration number if applicable e Product serial numbers Product model names and numbers e Applicable error messages e Operating system type and revision level e Detailed specific questions For continuous quality improvement calls may be recorded or monitored HP strongly recommends that customers sign up online using the Subscriber s choice web site http www hp com go e updates Subscribing to this service provides you with e mail updates on the latest product enhancements newest versions of drivers and firmware documentation updates as well as instant access to numerous other product resources e After signing up you can quickly locate your products by selecting Business support and then Storage under Product Category Subscription service HP strongly recommends that customers register online using the Subscriber s choice web site http www hp com go e updates Subscribing to this service provides you with e mail updates on the latest product enhancements newest driver versions and firmware documentation updates as well as instant access to numerous other product resources After subscribing locate your products by selecting B
27. national notices and statements 32 Canadian notice avis Canadien 32 Clase A equipmenl 6465540 Pas choad no ide ORG ab Kb a e at Pte EASE 32 European Union notice 2 2 eee ee 32 BSMiNOtICS sui omar a EE eae tc 32 Japanese notiee esa 33 Korean n tige SI 33 Salep O A 34 Electrostatic dischargers va iai ocena Rb RN ER on hh ey al en eas i este lt 34 Preventing electrostatic damage 2 2 2 cette eens 34 Grounding methods SENSE Ps 34 Ce E ee ee ee ares ee ee eee ee ee ee ee ee ae ee 35 Figures 1 Class 1 laser product label vaso 31 Tables 1 Document conventions 6 2 HBA environmental specifications e died dai A 10 3 HBA physical specifications LES 11 o AS A ae Hee 14 5 Adapter Settings dadas AA e abia dad 26 6 Advanced Adapter Settings i 28 About this guide This guide provides information about e Installing configuring and troubleshooting the HP StorageWorks FC1142SR single channel Peripheral Component Interconnect Express PCle 4Gb host bus adapter HBA and the HP StorageWorks FC1242SRSR DC dual channel PCle 4Gb HBA for Linux and Microsoft Windows operating systems hereafter called the FC1142SR HBA and the FC1242SR DC HBA or the HBAs Contacting technical support for additional assistance Intended audience This guide is intended for system administrators who are experienced with the following gt Linux operating systems e Win
28. nd contact by transporting and storing products in staticsafe containers Keep electrostatic sensitive parts in their containers until they arrive at static free workstations e Place parts on a grounded surface before removing them from their containers e Avoid touching pins leads or circuitry Always be properly grounded when touching a staticsensitive component or assembly see Grounding methods on page 34 Grounding methods There are several methods for grounding Use one or more of the following methods when handling or installing electrostatic sensitive parts e Use a wrist strap connected by a ground cord to a grounded workstation or computer chassis Wrist straps are flexible straps with a minimum of 1 megohm 10 percent resistance in the ground cords To provide proper ground wear the strap snug against the skin Use heel straps toe straps or boot straps at standing workstations Wear the straps on both feet when standing on conductive floors or dissipating floor mats Use conductive field service tools e Use a portable field service kit with a folding staticdissipating work mat If you do not have any of the suggested equipment for proper grounding have an HP authorized reseller install the part EY NOTE For more information on static electricity or assistance with product installation contact your HP authorized reseller 34 Regulatory compliance and safety Index A audience 5 B BSMI
29. nents inside Do not operate controls make adjustments or perform procedures to the laser device other than those specified herein Allow only HP authorized service technicians to repair the laser device Certification and classification information This product contains a laser internal to the fiber optic FO transceiver for connection to the Fibre Channel communications port In the USA the FO transceiver is certified as a Class 1 laser product conforming to the requirements contained in the Department of Health and Human Services DHHS regulation 21 CFR Subchapter J A label on the plastic FO transceiver housing indicates the certification Outside the USA the FO transceiver is certified as a Class 1 laser product conforming to the requirements contained in IEC 825 1 1993 and EN 60825 1 1994 including Amendment 11 1996 and Amendment 2 2001 Laser product label The optional label in Figure 1 or equivalent may be located on the surface of the HP supplied laser device CLASS 1 LASER PRODUCT Figure 1 Class 1 laser product label FC1142SR and FC1242SR DC 4Gb PCI Express host bus adapters for Linux and Windows installation guide 31 International notices and statements Canadian notice avis Canadien Class A equipment This Class A digital apparatus meets all requirements of the Canadian Interference Causing Equipment Regulations Cet appareil num rique de la classe A respecte toutes les exigences du R glem
30. op activity for the number of seconds specified by this setting The default is 5 seconds Adapter Hard Loop ID Forces the HBA to attempt to use the ID specified in the Hard Loop ID setting The default is Disabled Hard Loop ID When this setting has a Loop ID other than O the HBA uses the ID specified by this setting The default is 0 Spin Up Delay When this setting is enabled the BIOS waits up to two minutes to find the first drive The default is Disabled Connection Options Defines the connection type The default is 2 The options are e 0 loop e 1 Point to point e 2 loop preferred then point to point Fibre Channel Tape Support When this setting is enabled FCP 2 recovery can occur The default is Enabled Data Rate This setting determines the data rate The default is 2 The options are e O Runs at 1 Gb s 1 Runs at 2 Gb s 2 Aulo negotiates and determines the data rate 3 Runs at 4 Gb s Selectable Boot Settings This option lets you select the node from which you want to the system to boot When enabled this option forces the system to boot from the selected Fibre Channel hard disk ignoring any IDE hard disks connected to the system When disabled the system looks for a boot device specified in the system BIOS When disabled the Boot ID and Boot LUN parameters have no effect EY NOTE This option applies only to hard disks it does not apply to tape drives and other nondisk d
31. usiness support and then Storage under Product Category Helpful web sites For product information see the following web sites http www hp com http www hp com go storage htp www hp com support htfp www docs hp com FC1142SR and FC1242SR DC 4Gb PCI Express host bus adapters for Linux and Windows installation guide 7 HBA features This chapter describes the features of the FC1142SR part number AE311A and FC1242SR DC part number AE312A HBAs Performance specifications page 10 e Environmental specifications page 10 e Physical specifications page 11 FC1142SR and FC1242SR DC 4Gb PCI Express host bus adapters for Linux and Windows installation guide Performance specifications The FC1142SR HBA and the FC1242SR DC HBA are 4 Gb s Fibre Channel PCle HBAs The HBAs Fibre Channel controller incorporates a multifunction native PCle core that is compliant to the PCle Base Specification 1 0a and PCI e CEM Specification 1 0a The supported physical PCle connector is x4 x8 or x16 These HBAs have the following performance features Auto negotiation between 1 2 or 4Gb s link attachments High performance Fibre Channel host bus adapter Full support for all Fibre Channel topologies point to point arbitrated loop and fabric Full support for Fibre Channel Service Class 2 and Service Class 3 Compliance with the PCle Base and CEM 1 0a specifications e xl or x4 lane link interface auto negot

Download Pdf Manuals

image

Related Search

Related Contents

Les cartes chance des passe  User`s Manual  GSH Magnetic Beads for GST Tag Protein Purification letter  Life Fitness 93S User's Manual  L`art contemporain - Musée des Beaux-Arts  Pro Tools|HD Native User Guide    sn-920 ultra - Startechtel.com  BT-AJ型 充水バタフライ弁取扱説明書(H-43007) - バルブ事業部  Panasonic Close Curves  