1. 2 4 6 8 10 12 14 16 18 20 22 24 The Extender Cable provides communication between the hubs If you add an HP Management Module network management travels over this cable also You can connect an E xtender Cable when the power is on or off Never leave an Extender Cable unconnected at one end Longer Cables Option If you need longer cable order Long Extender Cable 71 cm 28 inch 5182 9869 from 1 800 538 8787 Note that a maximum of two Long Extender Cables are allowed per stack Verify That the Hub Works Correctly 1 Optional This productis supported by the HP J 2962A Redundant Power Supply RPS Ifyou have this HP RPS connect the RPS to the hub now Back of Hub Back of RPS HP AdvanceStack 10BT Switching Hubs Installation Guide 2 If you arenot using an RPS plug the included power cord into the hub s power cord receptacle and into an AC power source as shown below power receptacle on the back of the hub 3 Check the LEDs during self test Initially all LEDs are on except the Expansion Slot LEDs and Transceiver if an Expansion Slot Module or transceiver is not installed After the two second self test or 10 second self test with Management Module the following LEDs are on Power on
2. This installation guide describes how to 1 Verify included parts 2 Install any optional modules 3 Mount the hub 4 Connect the hubs together with Extender Cables 5 Verify that the hub operates correctly 6 Connect network cables using RJ 45 and telco connectors Throughout the manuals these hubs will be abbreviated as the Hub 12R Hub 24R and Hub 24T HP AdvanceStack 10BT Switching Hubs Installation Guide Verify Included Parts Each of the three HP Switching Hubs has the following components shipped with it HP AdvanceStack 1OBT Switching Hubs Installation Guide 5964 4661 HP AdvanceStack 10BT Switching Hubs Reference Manual 5964 4662 Topology Examples for the HP Switching Hubs 5182 9815 Warranty booklet Extender Cable 5182 9814 Accessory kit 5063 8570 shipped with the Hub 12R and Hub 24R e two mounting brackets e two cable ties e four M3 screws to attach brackets to hub e four 5 8 inch number 12 24 screws to attach hub to rack Accessory kit 5063 8603 shipped with the Hub 24T e all of the above plus two telco mounting hooks and two 4 40 screws to attach a telco hook to atelco plug Power cord one of the following Australia New Zealand 8120 6810 Denmark 8120 6814 Europe 8120 6811 J J apan 8120 6798 South Africa 8120 6813 Switzerland 8120 6815 United Kingdom 8120 680
3. PACKARD AdvanceStack Switching Hub 12R O HEWLETT Power Fault Security RPS RPS on if Redundant Power Supply is connected Hi p lel Dp oreen Management Slot Cy gC ag a gs a gg a a If the above behavior does not happen use this troubleshooting information to diagnose the problem Condition Power LED is OFF RPS LED is OFF and should be ON Module Fault LED is ON Hub Fault LED is ON Hub Fault LED is flashing Diagnostic Tip Check power cord and power source connections If connections are secure then try a different outlet or try a different power cord to see if the power cord is the problem The hub is not receiving power from the Redundant Power Supply RPS or the cable connection is loose If you have an RPS connected check the cable connections Try connecting the RPS to a different outlet Turn off the hub and reinsert this module making sure the screws are tightened If the Fault LED is still on insert the module into a different hub A hub or slot module hardware failure was detected during self test Self test does not complete so the LEDs will stay on longer than 60seconds If you have installed a Switch M odule in the stack verify that a Management M odule is also installed in that stack
4. Power cycle the hub If this condition persists the hub may have to be replaced Contact your HP authorized dealer or HP representative for assistance Corresponding LED such as RPS or port will also flash at the same time M ake sure SQE is disabled for the transceiver module if the AUI Xcvr LED is flashing If the above tips do not help see chapter 3 Troubleshooting in the Switching Hubs Reference Manual for additional information HP AdvanceStack 10BT Switching Hubs Installation Guide Connecting Network Cables Using RJ 45 Connectors To connect Push the RJ 45 plug into the RJ 45 jack until the tab on the plug clicks into place When power is on for the hub and the connected ae device the Port LED should light to confirm a powered on device e g end node Is at the other end of the cable lt RJ 45 plug To disconnect lt unshielded twisted pair cable Category 3 4 or5 sues plea sue ertne o i Cat 3 4 maximum distance 100 meters Cat 5 maximum distance 150 meters If the Port LED is not on use this table to solve the problem Condition Diagnostic Tip Port LED is still off Try Whenacableis For the indicated port verify that both ends of the cabling are snug hub and end node connected Verify the end node and hub are both on A different port or a different cable If you have installed t
5. 2606A M aximum Distance 1000 meters HP Twisted Pair Transceiver M odule HP J 2607A Category 3 4maximum Distance 100 meters Category 5 maximum Distance 150 meters HP ThinLAN Transceiver M odule HP J 2608A Maximum distance 185 meters Segment Display O HP AUI Port M odule HP J 2609A to attach external transceivers Do not use thi s port for Switching Hub to Switching Hub connecti ons in the stack See the documentation accompanying the optional transceiver modules for cabling configurations for those modules To usean external transceiver ona hub the SQE Test and Loopback Test options if present 12 HP AdvanceStack 10BT Switching Hubs Installation Guide must be disabled on the transceiver Cable Management The HP Switching Hubs have been designed to help you with the problem of managing your network cables On both sides of the front of each hub are two holes that accept a cable tie to tie wrap your cables lt cable tie continued on next page 13 HP AdvanceStack 10BT Switching Hubs Installation Guide Where to Go From Here Your hub is now correctly installed and is able to send and receives data between end nodes servers and printers Depending on your setup use this table to determine what steps need to be taken next Your Hub Setup Lint Switch in back Detailed Description One hub or stac
6. 9 United States Canada 8120 6812 HP AdvanceStack 10BT Switching Hubs Installation Guide Install Any Optional Modules Install optional modules into the Management Slot or the Expansion Slot by following the instructions in the manuals that accompany these products Q HEWLETT Power Fault Security RPS p PACKARD AdvanceStack Switching Hub 24R Front of Hub Management Slot HP J 3210A AdvanceStack 10BT Management M odule Segment Display O Base MAC Address ofa T E Back of Hub Expansion Slot HP J 3212A AdvanceStack Switch M odule 9 requires M anagement M odule in same hub or stack a os aman Note Before installing a module into the Expansion Slot or Management Slot unplug the hub If you do not install an optional module verify that the cover plate is still screwed into the slot HP AdvanceStack 10BT Switching Hubs Installation Guide Mount the Hub After the modules are inserted you are ready to put the hub in a stable location The Switching Hub can be mounted in three ways m oOnatable m inarack or cabinet m OnNawall Hub on a Table no tools needed Sturdy table in an isolated area Hub in a R
7. Kip HEWLETT PACKARD HP AdvanceStack 1OBT Switching Hubs Installation Guide The Switching Hubs area family of multiport repeaters With these hubs you can connect computers printers and servers together to exchange files This guide shows you how to install your Switching Hub The three models of the Switching Hubs are HP 3200A Switching Hub 12R HEWLETT PACKARD AdvanceStack Switching Hub 12R ell EDL rp ANA Vory AUI Xcvr Slot Q a 4 a Q Pi ti J ki af Q Py Management Slot a AAE aia CO aip eB TAE o HP 3202A Switching Hub 24R K P amp D p AnA voy AUI Xcvr Slot Management Slot E Wm r a Se ip at Ma e My e a re SP HP J 3204A Switching Hub 24T
8. ack or Cabinet The Switching Hub is designed to be mounted In any ElA standard 19 inch telco equipment rack To order a rack for your hub call HP at 1 800 538 8787 to order product number HP 46298D For your Safety read the mounting precautions in appendix C Safety and Regulatory in the Switching Hub Reference before mounting a hub 1 Attach the mounting brackets to the hub with the included 10 mm M4 screws HP AdvanceStack 10BT Switching Hubs Installation Guide 2 Partially install a screw 5 8 inch number 12 24 into the top hole of a pair of holes 0 5 inches apart in each rack cabinet upright Tighten each screw two turns Ensure that the screws in each upright are at the same level 3 Placethe hub inthe rack and lower it so the notches in the bottom of the bracket slide onto the screws Tighten these screws be careful not to overti ghten S 7 T UUU Upper hole in the bracket 0 X LLL Lower notch in the bracket HP AdvanceStack 10BT Switching Hubs Installation Guide 4 Install the other number 12 24 screw into the upper hole in each bracket Tighten these screws be careful not to overtighten BS Ny YYW Install additional screw S MM LLL HP AdvanceStack 10BT Switching Hubs Installation Guide Mounting the Hub on a Wall You can put one hub ona wall or stack two hubs together ona wall Not
9. e that a hub should be mounted only to a wall or wood surface that is at least 1 2 inch plywood or its equivalent Attach the hub to the wall or wood surface with 5 8 inch number 12 wood screws not included One hub ona wall Two hubs ona wall HP AdvanceStack 10BT Switching Hubs Installation Guide Connecting the Switching Hubs Together with Extender Cable Attach the included Extender Cable from one hub to another GD PACKARD Power Fault Security RPS AdvanceStack Switching Hub 12R Gor q can be installed CR comers in this orientation TRE eenaa An only
10. ge without notice All rights reserved Reproduction adapta tion or translation without prior written per mission is prohibited except as allowed under the copyright laws 1996 Hewlett Packard Company HP Part Number 5964 4661 Edition 1 August 1996 Printed in Singapore
11. he Management M odule use the ASCII console or HP AdvanceStack Assistant to determine the state of the port and re enable the port if desired Note Do not use twisted pair thin coax or fiber cables to make a Switching Hub to Switching Hub connection across the stack The Extender Cable is for Switching Hub to Switching Hub connections only 10 HP AdvanceStack 10BT Switching Hubs Installation Guide Using Telco Connectors with the Hub 24T If you prefer to make your twisted pair connections through a cross connect block wiring closet or other intermediary connection the Hub 24T has industry standard 50 pin telco connectors Devices connected to the hub s 50 pin telco connector through N a cross connect block r Hub 24T 11 HP AdvanceStack 10BT Switching Hubs Installation Guide To use a telco connector A 1 Attach the mounting hook with the 1 2 inch 4 40 screw KE 2 Insert hook in slot on the hub s face 3 Pivot the telco plug onto the connector and press into place 4 Tighten the screw on the telco plug Be careful not to overtighten the screw To remove a telco connector reverse this process AUI Xcvr Slot An optional transceiver module can be installed in the hub s AUI Xcvr slot to provide additional connectivity choices including HP Fiber Optic Transceiver M odule HP J
12. k of 2 or more hubs with No Management M odule No Switch Module Stack of 2 or more hubs with Management M odule Switch Module Stack of one or more hubs with ManagementM odule only Communication Status All users are on seg ment 1 and can com municate together All users are distribut ed evenly over seg ments 1 2 3 and 4and can communicate to gether All users are on seg ment 1 and can com municate together W hat You Need to Do No software configuration needed If Actor Col LEDs are on all of the time add a Management M odule and exter nal switch or Switch M odule to distrib ute ports evenly over the four segments No software configuration or optimiza tion needed If Act and Col LEDs are on most of the time segment your stack by either adding a Switch M odule adding more LAN adapters to the servers adding an external switch If you only add a Management M odule and move the ports to other segments in software remember that users cannot communicate between the segments Add an external switch or Switch M od ule to this stack for communication be tween all the segments If you need to set the IP address see the Management Module manual for information on how to use the ASCII console or HP AdvanceStack Assistant For a Novell Netware network no configuration is necessary 14 HEWLETT K PACKARD Technical information in this document is subjectto chan

Download Pdf Manuals

image

Related Search

Related Contents

USB2-PCIL4 取扱説明書    IGM Module  FuelMaster® - Odys  QNAP QGenie QG-103N User Manual  Training Manual for Thin Film Group End Point Detection  SP Attach Manual - kalmstrom.com Business Solutions  2013.12.12 Liquid Rhythm Intro User Manual v1.1  Gemmy 26812 Use and Care Manual  Pulse IP Camera User Manual 3.0.1.2_for User(P2DS)  