1. Range Hoods GEAppliances com Safety Information 2 3 Operating Care and Cleaning Instructions Charcoal Piltefs 5 sveceseysgse 5 Grease Filter os cows ceeeeeeew ocean 4 Hood GIJN Re 5 Hood SUnAees sesissns 5 CONO Seena es res 4 Installation Instructions 6 14 Consumer Support Consumer Support Back Cover Warranty es dise oaudhrasase 15 Ds A A CERTIFIED Write the model and serial numbers here Model Serial You can find them on a label on the back wall of the hood Owner s Manual and Installation Instructions JV247 Vent amp Recirculation options JV248 Vent amp Recirculation options JN327 Recirculation only JV338 Vent options only JV347 Vent amp Recirculation options JV348 Vent amp Recirculation options JV367 Vent amp Recirculation options RN328 Recirculation only 49 80589 2 08 12 GE IMPORTANT SAFETY INFORMATION READ ALL INSTRUCTIONS BEFORE USING 4 _ SAFETY PRECAUTIONS WARNING TO REDUCE THE RISK OF FIRE ER Y ELECTRIC SHOCK OR INJURY TO PERSONS OBSERVE THE FOLLOWING A Use this unit only in the manner intended by the manufacturer If you have questions contact the manufacturer B Before servicing or cleaning unit switch power off at service panel and lock the service disconnecting means to prevent power from being switched on accidentally When the service disconnecting means cannot be locked secur
2. Tape measure Wire stripper Flashlight Caulking Level PARTS INCLUDED PART rs Grease Filter only JV338 Charcoal Filter only JN327 and RN328 Grease Filter and Charcoal Filter JV24x JV347 JV348 and JV367 Mounting Screws 8 18 x 3 4 Phillips pan head Exhaust Adaptor for 3 x 10 rect venting Exhaust Adaptor Screw 8 18 x 3 8 Phillips pan head or hex head Installation Instructions CHOOSE VENT OPTION Determine the vent option that your installation will require and that is available for your model from the below choices Outside top exhaust Vertical duct 3 1 4 x 10 Rectangular Outside top exhaust Vertical duct 7 Round 1338 t San IMPORTANT If the hood is to be installed in a recirculating non vented ductless manner do not knock out any vent openings in the hood Only an electrical access hole will be knocked out of the hood Outside rear exhaust Horizontal duct 3 1 4 x 10 Rectangular Recirculating non vented ductless JN327 RN328 Installation Instructions REMOVE EXHAUST ADAPTOR If exhausting venting using the 37x 10 rectangular duct optional for JV247 JV248 JV338 JV347 JV348 and JV367 models only Remove the exhaust adaptor from the inside of the hood Set it aside along with its mounting screws REMOVE FILTER Remove the shipping ta
3. The filter will then slip out of the retaining tabs on the back To replace Slip the back edge of the filter into the retaining tabs and push the front edge up until it snaps into place Stainless Steel Surfaces on some models Do not use a steel wool pad it will scratch the surface To clean the stainless steel surface use warm sudsy water or a stainless steel cleaner or polish Always wipe the surface in the direction of the grain Follow the cleaner instructions for cleaning the stainless steel surface Painted Surfaces on some models Do not use steel wool pads or other abrasive cleaners They will scratch the surface Clean grease laden surfaces of the hood frequently To clean the hood surface use a hot damp cloth with a mild detergent suitable for painted surfaces About one tablespoon of ammonia may be added to the water Use a clean hot damp cloth to remove soap Dry with a dry clean cloth Hood Light CAUTIONS ct the ight bub cool completely before removing A warm or hot bulb may break if touched with a moist cloth or hand Remove the bulb and replace it with a type A15 incandescent light bulb with an ordinary screw base not more than 60 Watts or a type A17 or T2 Compact Fluorescent CFL light bulb with an ordinary screw base not more than 13 Watts NOTE Use only incandescent bulbs in models RN328 JN327 and JV338 IMPORTANT For installation handling and disposal precautions r
4. s curit comme celles publi es par la National Fire Protection Association NFPA l American Society for Heating Refrigeration and Air Conditioning Engineers ASHRAE ainsi que les modalit s des codes locaux Le cas ch ant installez un syst me de compensation d air remplacement conform ment aux conditions des codes locaux du b timent C Si vous faites un trou ou une ouverture dans un mur ou un plafond n endommagez pas les fils lectriques et les autres installations cach es de service public D Vous devez toujours alimenter les ventilateurs dans les conduits en air en provenance de l ext rieur AA VERTISSEMENT POUR R DUIRE LE RISQUE D INCENDIE ET VACUER AD QUATEMENT L AIR ASSUREZ VOUS DE FAIRE D BOUCHER LA CONDUITE D AIR L EXT RIEUR NE VENTILEZ PAS L AIR VACU DANS DES ESPACES COMPRIS A L INT RIEUR DE MURS D UN PLAFOND D UN GRENIER D UN VIDE SANITAIRE OU D UN GARAGE AA VERTISSEMENT pour r ouire LE RISQUE D INCENDIE N UTILISEZ QUE DES CONDUITS EN METAL E N essayez jamais de remplacer ou de r parer un l ment de votre hotte si le pr sent manuel ne le recommande pas express ment Tout autre entretien doit tre effectu par un technicien qualifi Qo QD lt 20 T_ LISEZ ET SUIVEZ ATTENTIVEMENT CES INSTRUCTIONS LISEZ ET CONSERVEZ CES INSTRUCTIONS Using the hood controls Throughout this manual features and appearance
5. 16 36 hood Hood mounting Center line Electrical access screws 4 hole in wall D Recirculating non vented ductless JN327 and RN328 and optional on JV247 JV248 JV347 JV348 and JV367 models only e Use the hood as a template and mark the locations on the cabinet for the electrical wiring and keyhole screw slots e Since the hood is to be recirculated not to be vented outside do not cut out any vent openings in the wall or cabinet bottom CUT HOLES Cut holes at marked locations for duct and electrical wiring For the vertical duct cut out 3 4 extra toward the front of the cabinet so you can move the duct freely when installing the hood It may also ease installation by cutting the hole 10 instead of 10 RUN WIRES Run the electrical wires through the wall or cabinet according to National Electrical Code and applicable local codes NOTE DO NOT turn the power on until installation is complete Installation Instructions SCREW IN PART WAY Drive a mounting screw from the hardware packet part way into each center of the narrow neck of the keyhole slots marked on the cabinet bottom OPTIONAL POWER CORD KIT JXHC1 An optional Power Cord Connection Kit model JXHC1 is available at extra cost from your GE supplier for installation using a standard 3 prong grounded wall outlet Follow the Installation Instructions packed with the kit to connect the power cor
6. 6 hood Cabinet front 10 24 hood 13 30 hood 16 36 hood Wood shim recessed bottom cabinets only shims must be a minimum of 3 8 thick and cut to fit the width of the inner recessed cabinet bottom Center lin cabinet bottom line B Outside top exhaust Vertical duct 7 Round e Use the diagram or the hood as a template and mark the locations on the cabinet for ductwork electrical wiring and keyhole screw slots Hood mounting screws 4 10 24 hood 10 24 hood 13 30 hood 13 30 hood 16 36 hood gt lt 16 36 hood Cabinet front N e Cabinet f Access AA 9 hole for 7 m a round duct S 134 Wood shims recessed A Electrical access bottom cabinets only shims Center hole in cabinet bottom must be a minimum of 3 8 Jine thick and cut to fit the width of the inner recessed cabinet bottom C Outside rear exhaust Horizontal duct 3 1 4 x 10 Rectangular e Use the diagram or the hood as a template and mark the locations on the cabinet for ductwork electrical wiring and keyhole screw slots Wood shims recessed bottom cabinets only shims must be a minimum of 3 8 thick and cut to fit the width of the inner recessed cabinet bottom Cabinet front q fr id a Cabinet bottom M 5 gt e 5 gt e 73 10 24 hood le 10 24 hood 13 30 hood 13 30 hood 16 36 hood A
7. A CUISINIERE NZ PRECAUTIONS EN MATI RE DE S CURIT Ne laissez jamais sans surveillance les unit s de cuisson de surface une temp rature lev e Le bouillonnement occasionne des d bordements fumants et graisseux qui peuvent prendre feu Chauffez feu doux les substances huileuses avec un r glage bas ou moyen B ALLUMEZ toujours la hotte en cas de cuisson feu lev ou lorsque vous faites flamber des aliments par exemple cr pes Suzette cerises jubil es boeuf au poivre flamb C Nettoyez les m canismes de ventilation fr quemment Il ne faut pas permettre une accumulation de graisse sur le ventilateur ou sur le filtre D Utilisez une casserole de bonne taille Utilisez toujours un ustensile de cuisine qui convienne au diam tre de l l ment de cuisson AA VERTISSEMENT POUR R DUIRE LE RISQUE D INCENDIE DE SECOUSSE LECTRIQUE OU DE BLESSURE CORPORELLE OBSERVEZ LES PRECAUTIONS SUIVANTES A Vous devez faire ex cuter tous les travaux d installation de c blage lectrique par une personne qualifi e onform ment tous les codes et les normes en vigueur en articulier ceux de construction relatifs ux incendies ous devez assez d air pour avoir une bonne combustion et ermettre l vacuation des gaz par le conduit de chemin e u mat riel de combustion du carburant afin d viter tout retour d air Suivez les directives du fabricant de mat riel de combustion et les normes de
8. E SURE TO DUCT AIR OUTSIDE DO NOT VENT EXHAUST AIR INTO SPACES WITHIN WALLS OR CEILINGS OR INTO ATTICS CRAWL SPACES OR GARAGES A WARNING TO REDUCE THE RISK OF FIRE USE ONLY METAL DUCTWORK E Do not attempt to repair or replace any part of your hood unless it is specifically recommended in this guide All other servicing should be referred to a qualified technician O Via READ AND FOLLOW THIS SAFETY INFORMATION CAREFULLY T N READ AND SAVE THESE INSTRUCTIONS INSTRUCTIONS DE S CURIT IMPORTANTES LISEZ TOUTES LES INSTRUCTIONS AVANT D UTILISER LAN Vis ON AA VERTISSEMENT POUR REDUIRE LE RISQUE D INCENDIE DE SECOUSSE LECTRIQUE OU DE BLESSURE CORPORELLE OBSERVEZ LES PRECAUTIONS SUIVANTES A N utilisez cet appareil que de la mani re pr vue par le fabricant Si vous avez des questions appelez le fabricant B Avant de r parer ou de nettoyer votre appareil d branchez le courant au niveau du panneau de service et verrouillez les m canismes de d branchement de service pour viter tout branchement accidentel au courant Si vous ne pouvez pas verrouiller les m canismes de d branchement de service attachez soigneusement un avertissement bien visible comme une tiquette au panneau de service C N utilisez jamais cet appareil avec un m canisme de r glage de la vitesse semi conducteurs D Si vous utilisez l ensemble de cordon de raccordement utilise seulement avec l ensem
9. NG CHECKLIST f the hood seems to be operating at high speed when the control is not set on high or if ventilation seems inadequate check the following J Knockouts not removed from hood D Damper blade not opening T Reduced airflow because the duct is too small or the duct length is too long LJ The duct is blocked 4 Undersized or restrictive wall or roof cap f the hood seems to make excessive noise Q Fan may be hitting the filter Turn off the fan and remove the filter Bend the filter down slightly in the center into a dome shape to allow fan clearance Reinstall and adjust as needed The fan does not work but the lights do Q Switch power off at the service panel and lock the service disconnecting means to prevent power from being switched on accidentally When the service disconnecting means cannot be locked securely fasten a prominent warning device such as a tag to the service panel 4 Check the wiring connections See the CONNECT WIRING section in these Installation Instructions GE Range Hood Warranty authorized Customer Care technician To schedule service visit us Proof of the original purchase on line at GEAppliances com or call 800 GE CARES 800 432 2737 ae needed ob cence Please have serial number and model number available when under the warranty oe All warranty service provided by our Factory Service Centers or an Staple your receipt here calling for service Fo
10. RTANT For installation handling and disposal precautions refer to the fluorescent bulb packaging literature When using an energy saving bulb in your GE hood make sure you use GE Long Life Energy or Smart Spiral T2 Product Code 85383 Description FLE13HT2 2 SW CD GE Long Life Energy Smart A17 Product Code 47486 Description FLE11 2 A17XL CD Available at www gelighting com FOLLOW ELECTRICAL CODE Complete the electrical wiring according to National Electrical Code and local codes NOTE This hood must be permanently grounded Connect house wiring 120 VAC to hood wiring CONNECT WIRING Connect house black to hood black wire house white to hood white wire and house ground under green ground screw Securely tighten the strain relief clamp onto the house wiring 7 DA re amp n round vee A WARNING IMPROPER CONNECTION OF ALUMINUM HOUSE WIRING TO THESE COPPER LEADS CAN RESULT IN A SERIOUS PROBLEM USE ONLY CONNECTORS DESIGNED FOR JOINING COPPER TO ALUMINUM AND FOLLOW THE MANUFACTURER S RECOMMENDED PROCEDURE CLOSELY REPLACE WIRING COVER Wiring cover REPLACE FILTER Make sure fan blade turns freely and replace the filter NOTE Install the metal grease filter if ducted or the charcoal filter if recirculated Metal grease filter or charcoal filter The installation is complete Turn on power at service panel and test for proper operation TROUBLESHOOTI
11. ble de cordon de raccordement pour hotte JXHC1 Suite un examen technique l article JXHC1 s est av r compatible avec ce mod le de hotte Cet appareil doit tre bien mis la terre AA TTENTION UNIQUEMENT USAGE DE VENTILATION G N RALE N UTILISEZ JAMAIS POUR L CHAPPEMENT DE MATI RES ET DE VAPEURS EXPLOSIVES AA VERTISSEMENT pour r ouire te RISQUE DE BLESSURE CORPORELLE SI DE LA GRAISSE PREND FEU SUR LA SURFACE DE CUISSON DE LA CUISINIERE SUIVEZ LES INSTRUCTIONS SUIVANTES A TOUFFEZ LES FLAMMES avec un couvercle qui convient une t le biscuits ou un plateau en m tal puis teignez le br leur FAITES BIEN ATTENTION DE NE PAS VOUS BRULER Si les flammes ne s teignent pas imm diatement SORTEZ ET APPELEZ LES POMPIERS B NE D PLACEZ JAMAIS UNE CASSEROLLE QUI FLAMBE Vous pouvez vous br ler C N UTILISEZ JAMAIS D EAU en particulier de serviette ou de chiffon mouill il se produira une explosion violente de vapeur br lante D N UTILISEZ UN EXTINCTEUR que si 1 Vous avez un extincteur de classe ABC et vous savez comment l utiliser 2 Le feu est r duit et confin l endroit o il a commenc 3 Vous avez d j appel les pompiers 4 Vous combattez les flammes en tournant le dos une sortie Bas sur l ouvrage intitul Kitchen Fire Safety Tips publi par la NFPA AA VERTISSEMENT pour r ouire te RISQUE D UN FEU DE GRAISSE SUR LA SURFACE DE CUISSON DE L
12. cal building code requirements EQUIVALENT NUMBER LENGTH X USED 3 x 10 rect transition 7 Round 14 Ft 90 elbow 7 Round 9 Ft 45 elbow rect transition 90 elbow Subtotal column 2 Subtotal column 1 Total ductwork Installation Instructions DAMAGE SHIPMENT INSTALLATION e If the unit is damaged in shipment return the unit to the store in which it was bought for repair or replacement e If the unit is damaged by the customer repair or replacement is the responsibility of the customer e If the unit is damaged by the installer if other than the customer repair or replacement must be made by arrangement between customer and installer Bottom edge of cabinet needs to be 30 or more from the cooking surface 24 30 or 36 to match cooktop MOUNTING SPACE 66 or NS from the floor to the top ofthe hood NOTES e Hood width may be greater than the width of the range or cooktop but it may not be smaller e Ensure the range or cooktop is installed per manufacturer s installation instructions e If you are going to vent your range hood to the outside see the Ducting Requirements section for exhaust duct preparation TOOLS YOU WILL NEED Flat blade and Phillips Pencil screwdrivers Duct tape PA Saw saber or Electric drill Metal snips keyhole in some applications Se A 1 4 Pliers pivoting hex socket 0 SS e 1 4 Nutdriver
13. d to the range hood Cabinet 3 prong wall outlet if using cord connection 1 dia clearance hole for optional power supply location NOTE If using optional Power Cord Kit JXHC1 feed the power cord through the hole in the top cabinet while raising the hood Loop any excess length of cord and tie away with a suitable tape or tie FEED IN WIRES Lift the hood into position and feed the house wiring through the wiring knockout SECURE HOOD Slide the hood back against the wall Tighten the mounting screws Be sure the screw heads are in the narrow neck of the keyhole slot a Mounting a screw 4 Keyhole 4 NOTE DO NOT PUSH ON THE FAN BLADE Pushing on the blade may cause it to interfere with other hood parts CONNECT DUCTWORK TO HOOD Ducted installations only On 7 round installations attach the 7 duct with sheet metal screws through the holes in the alignment ears 7 round duct Duct tape Installation Instructions INSTALL LIGHT BULB NOTE A light bulb is not shipped with the hood Obtain one locally Purchase and install a type A15 incandescent light bulb with an ordinary screw base not more than 60 Watts or a type A17 or T2 Compact Fluorescent CFL light bulb with an ordinary screw base not more than 13 Watts NOTE Use only incandescent bulbs in models RN328 JN327 and JV338 IMPO
14. dge of the filter into the retaining tabs and push the front edge up until it snaps into place To clean Soak and then agitate it in a hot water and detergent solution Light brushing can be used to remove embedded dirt Rinse shake and let it dry before replacing NEVER OPERATE THE HOOD WITHOUT THE FILTER IN PLACE With careful handling the metal filter will last for years If a new replacement filter becomes necessary order the part from your dealer Order genuine GE part number WBO2X8391 Replaceable charcoal filter NOTE DO NOT rinse or put charcoal filters in an automatic dishwasher A Light cover o When using an energy saving bulb in your GE hood make sure you use either GE Long Life Energy Smart Spiral T2 Product Code 85383 Description FLE13HT2 2 SW CD or GE Long Life Energy Smart A17 Product Code 47486 Description FLE11 2 A17XL CD Available at www gelighting com Charcoal Filter Recirculating Installations Only The charcoal filter cannot be cleaned It must be replaced Order filter no WB02X10700 Replacement filters can be ordered from your GE supplier If the hood is not vented to the outside the air will be recirculated through a disposable charcoal filter that helps remove smoke and odors The charcoal filter should be replaced after 6 to 12 months depending on hood usage To remove Pull down on the center of the front edge of the filter
15. efer to the fluorescent bulb packaging literature To inquire about purchasing stainless steel appliance cleaner or polish or to find the location of a dealer nearest you please call our toll free number National Parts Center GEApplianceParts com 800 626 2002 NOTE When cleaning take care not to come in contact with filters and other non enameled surfaces A CAUTION when cleaning the hood surfaces be certain that you do not touch the light bulb with moist hands or cloth A warm or hot light bulb may break if touched with a moist surface Always let the light bulb cool completely before cleaning around it To remove the light cover on some models e Press the sides with two fingers until the side prongs are released e Lift the light cover and slide it toward you in one motion To replace the light cover e Insert the prong located at the end of the cover into the top opening e Gently push the cover up and press the sides to fit the side prongs into the side openings e Release and the cover will lock in position Installation Instructions BEFORE YOU BEGIN Read these instructions completely and carefully IM PO RTANT Save these instructions for local inspector s use IM PORTANT Observe all governing codes and ordinances Note to Installer Be sure to leave these instructions with the Consumer Note to Consumer Keep these instructions for future reference Skill level In
16. ely fasten a prominent warning device such as a tag to the service panel C Do not use this unit with any solid state speed control device D If using a cord connection kit use only with range hood cord connection kit JXHC1 that has been investigated and found acceptable for use with this model range hood This unit must be grounded ACAUTION FOR GENERAL VENTILATING USE ONLY DO NOT USE TO EXHAUST HAZARDOUS OR EXPLOSIVE MATERIALS AND VAPORS A WARNING TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT OF A RANGE TOP GREASE FIRE OBSERVE THE FOLLOWING A SMOTHER FLAMES with a close fitting lid cookie sheet or metal tray then turn off the burner BE CAREFUL TO PREVENT BURNS If the flames do not go out immediately EVACUATE AND CALL THE FIRE DEPARTMENT B NEVER PICK UP A FLAMING PAN You may be burned C DO NOT USE WATER including wet dishcloths or towels a violent steam explosion will result D Use an extinguisher ONLY if 1 You know you have a Class ABC extinguisher and you already know how to operate it 2 The fire is small and contained in the area where it started 3 The fire department is being called 4 You can fight the fire with your back to an exit Based on Kitchen Firesafety Tips published by NFPA A WARNING TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE A Never leave surface units unattended at high settings Boilovers cause smoking and greasy spillove
17. kout only Installation Instructions FOR 3 1 4 X 10 RECTANGULAR DUCTED DISCHARGE INSTALLATIONS ONLY Attach exhaust adaptor damper over the appropriate knockout opening for vertical or horizontal depending on installation with two exhaust adaptor screws Make sure damper pivot is nearest to top back edge of hood Remove tape from damper flap Exhaust adaptor damper vertical discharge position Pivot depending on installation it Top back edge Exhaust adaptor damper horizontal discharge position 9 FOR 7 ROUND VERTICAL DUCTED DISCHARGE INSTALLATIONS ONLY Bend up the duct alignment ears in preparation for later attachment of the 7 duct 11 FOR RECESSED BOTTOM CABINETS ONLY Lu w Wood shims minimum thickness 3 8 e f the cabinets have front side or back trim make 2 wood shims a minimum of 3 8 thick and cut to fit the width of the inner recessed cabinet bottom Attach them to the cabinet bottom recess on both sides See Step 11 for marking locations Installation Instructions MARK HOLES Select the vent option that your installation will require and proceed to that section A Outside top exhaust Vertical duct 3 1 4 x 10 Rectangular e Use the diagram or the hood as a template and mark the locations on the cabinet for ductwork electrical wiring and keyhole screw slots Hood mounting screws 4 10 24 hood 13 30 hood 16 3
18. luded Exhaust connection The hood exhaust has been designed to mate with standard 3 x 10 rectangular ducting or 7 diameter round ducting If a 6 round duct is required a rectangular to round transition adaptor must be used Do not use less than a 6 diameter duct Maximum duct length For satisfactory air movement the total duct length of a 3 x 10 rectangular 6 or 7 diameter round duct should not exceed 65 equivalent feet See the WORKSHEET CALCULATE TOTAL EQUIVALENT DUCTWORK LENGTH section NOTE It is important that ducting be installed using the most direct route and with as few elbows as possible This ensures clear venting of exhaust and helps prevent blockages Also make sure dampers swing freely and nothing is blocking the ducts When applicable install any makeup replacement air system in accordance with local building code requirements Elbows transitions wall and roofcaps etc present additional resistance to airflow and are equivalent to a section of straight duct longer than their actual physical size When calculating the total duct length add the equivalent lengths of all transitions and adaptors plus the length of all straight duct sections The charts on the following pages show you how to calculate total equivalent ductwork length using the approximate feet of equivalent length of some typical ducts IMPORTANT If a rectangular to round transition adaptor is used the botto
19. m corners of the damper will have to be cut to fit using the tin snips in order to allow free movement of the damper Equivalent lengths of duct pieces are based on actual tests and reflect requirements for good venting performance with any hood Installation Instructions WORKSHEET CALCULATE TOTAL EQUIVALENT DUCTWORK LENGTH DUCT EQUIVALENT NUMBER PIECES LENGTH x USED TOTAL 3 x 10 Rect straight 7 Round straight 6 Round straight 3 x 10 Rect 90 elbow 3 x 10 Rect 45 elbow 3 4 x 10 Rect 90 flat elbow 3 x 10 Rect wall cap with damper 3 4 x 10 Rect to 6 round transition 3 x 10 Rect to 6 round transition 90 elbow 6 Round 25 Ft 90 elbow 6 Round 16 Ft 45 elbow Subtotal column 1 MAXIMUM DUCT LENGTH For satisfactory air movement the total duct length of a 3 x 10 rectangular 7 diameter round duct should not exceed 65 equivalent feet NOTE Any home ventilatoin system such as a ventilation hood may interrupt the proper flow of combustion air and exhaust required by fireplaces gas furnaces gas water heatrs and other naturally vented systems To minimize the chance of interruption of such naturally vented systems follow the heating equipment manufacturer s guidelines and safety standards such as those published by NFPA and ASHRAE When applicable install any makeup replacement air system in accordance with lo
20. may vary from your model Control Knobs on some models FAN Control Turn to HI MED or LO as needed Continuous use of the fan system while cooking helps keep the kitchen comfortable and less humid It also reduces cooking odors and soiling moisture that create a frequent need for cleaning LIGHT Control Turn to ON while cooking or to NITE for use as a night light Switch Pad Controls on some models ON OFF HI g OFF LO LIGHT Control Press the pad at the top to turn the light ON O FAN Control Press the pad at the top to turn the fan on HI and at the bottom to turn it on LO The center position is OFF Continuous use of the fan system while cooking helps keep the kitchen comfortable and less humid It also reduces cooking odors and soiling moisture that create a frequent need for cleaning Care and cleaning of the vent hood Be sure electrical power is off and all surfaces are cool before cleaning or servicing any part of the vent hood mi Grease filter Reusable Metal Grease Filter Ducted Installations Only The efficiency of your hood depends on a clean filter Frequency of cleaning depends on hood use and the type of cooking you do However the grease filter should be cleaned at least once a month To remove Pull down on the center of the front edge of the filter The filter will then slip out of the retaining tabs on the back To replace Slip the back e
21. pe holding the metal grease filter in place Pull down on the center of the front edge of the filter The filter will then slip out of the retaining tabs on the back Metal grease filter REVERSE THE BAFFLE FOR DUCTED INSTALLATIONS ONLY JV247 JV248 JV347 JV348 and JV367 models If the hood is to be recirculated skip to the next step Remove the baffle from the top of the hood Reinstall the baffle so the short side marked VENTED is visible The long side of the baffle should be inside the hood VENTED is visible 1 1 REMOVE WIRING COVER Remove the wiring cover from inside the hood Set the cover and its mounting screws aside Wiring Ly REMOVE WIRING KNOCKOUT Remove either the top or the back wiring knockout as needed and install an approved strain relief clamp Top Back knockout knockout Strain relief Strain relief clamp REMOVE DUCT KNOCKOUT If recirculating non vented ductless JN327 and RN328 and optional for JV247 JV248 JV347 JV348 and JV367 models only skip to Step 11 D and proceed Using a flat blade screwdriver remove the appropriate duct knockout from the top or back of the hood 3 x 10 Rectangular 7 Round vertical discharge vertical discharge Remove circular duct Remove top rectangular knockout only duct knockout only 3 x 10 Rectangular horizontal discharge Remove rear rectangular duct knoc
22. r The Period Of GE Will Replace One Year Any part of the range hood which fails due to a defect in materials or workmanship From the date of the During this limited one year warranty GE will also provide free of charge all labor and original purchase in home service to replace the defective part What GE Will Not Cover E Service trips to your home to teach you how to use E Incidental or consequential damage caused by possible the product defects with this appliance Improper installation delivery or maintenance E Damage caused after delivery E Failure of the product if it is abused misused or E Product not accessible to provide required service used for other than the intended purpose or used E Installation or service for a makeup replacement air commercially system E Replacement of house fuses or resetting of circuit breakers E Damage to the product caused by accident fire floods or acts of God EXCLUSION OF IMPLIED WARRANTIES Your sole and exclusive remedy is product repair as provided in this Limited Warranty Any implied warranties including the implied warranties of merchantability or fitness for a particular purpose are limited to one year or the shortest period allowed by law This warranty is extended to the original purchaser and any succeeding owner for products purchased for home use within the USA If the product is located in an area where service by a GE Authorized Servicer is not available you ma
23. rs that may ignite Heat oils slowly on low or medium settings B Always turn hood ON when cooking on high heat or when flambeing food i e Crepes Suzette Cherries Jubilee Peppercorn Beef Flamb C Clean ventilating fans frequently Grease should not be allowed to accumulate on fan or filter D Use proper pan size Always use cookware appropriate for the size of the surface element A WARNING TO REDUCE THE RISK OF FIRE ELECTRIC SHOCK OR INJURY TO PERSONS OBSERVE THE FOLLOWING A Installation work and electrical wiring must be done by qualified person s in accordance with all applicable codes and standards including fire rated construction B Sufficient air is needed for proper combustion and exhausting of gases through the flue chimney of fuel burning equipment to prevent back drafting Follow the heating equipment manufacturer s guideline and safety standards such as those published by the National Fire Protection Association NFPA the American Society for Heating Refrigeration and Air Conditioning Engineers ASHRAE and the local code authorities When applicable install any makeup replacement air system in accordance with local building code requirements C When cutting or drilling into wall or ceiling do not damage electrical wiring and other hidden utilities D Ducted fans must always be vented to the outdoors A WARNING TO REDUCE THE RISK OF FIRE AND TO PROPERLY EXHAUST AIR B
24. s Universal Design applications including kitchen design ideas for people with disabilities check out our Website today For the hearing impaired please call 800 TDD GEAC 800 833 4322 Extended Warranties GEAppliances com Purchase a GE extended warranty and learn about special discounts that are available while your warranty is still in effect You can purchase it on line anytime or call 800 626 2224 during normal business hours GE Consumer Home Services will still be there after your warranty expires Parts and Accessories GEApplianceParts com Individuals qualified to service their own appliances can have parts or accessories sent directly to their homes VISA MasterCard and Discover cards are accepted Order on line today 24 hours every day or by phone at 800 626 2002 during normal business hours Instructions contained in this manual cover procedures to be performed by any user Other servicing generally should be referred to qualified service personnel Caution must be exercised since improper servicing may cause unsafe operation Contact Us GEAppliances com KA If you are not satisfied with the service you receive from GE contact us on our Website with all the details including your phone number or write to General Manager Customer Relations GE Appliances Appliance Park Louisville KY 40225 Register Your Appliance GEAppliances com Register your new appliance on line at your convenience Timely product regis
25. stallation of this appliance requires basic mechanical and electrical skills Completion time 30 minutes 3 hours Proper installation is the responsibility of the installer Product failure due to improper installation is not covered under the Warranty FOR YOUR SAFETY AWARN NG Before beginning the installation switch power off at service panel and lock the service disconnecting means to prevent power from being switched on accidentally When the service disconnecting means cannot be locked securely fasten a prominent warning device such as a tag to the service panel OPTIONAL POWER CORD KIT JXHC1 An optional Power Cord Connection Kit model JXHC1 is available at extra cost from your GE supplier for installation using a standard 3 prong grounded wall outlet Follow the Installation Instructions packed with the kit to connect the power cord to the range hood Range Hood DUCTWORK REQUIREMENTS NOTE Read the ductwork sections only if you do not have existing ductwork If you have existing ductwork skip to the Damage section and proceed WARN NG TO REDUCE THE RISK OF FIRE AND TO PROPERLY EXHAUST AIR BE SURE TO DUCT AIR OUTSIDE DO NOT VENT EXHAUST AIR INTO SPACES WITHIN WALLS OR CEILINGS OR INTO ATTICS CRAWL SPACES OR GARAGES The venting system must exhaust to the outside This hood can be vented vertically through upper cabinets or horizontally through an outside wall Ductwork is not inc
26. tration will allow for enhanced communication and prompt service under the terms of your warranty should the need arise You may also mail in the pre printed registration card included in the packing material Printed in China
27. y be responsible for a trip charge or you may be required to bring the product to an Authorized GE Service Location for service In Alaska the warranty excludes the cost of shipping or service calls to your home Some states do not allow the exclusion or limitation of incidental or consequential damages This warranty gives you specific legal rights and you may also have other rights which vary from state to state To know what your legal rights are consult your local or state consumer affairs office or your state s Attorney General Warrantor General Electric Company Louisville KY 40225 15 Consumer Support GE Appliances Website GEAppliances com Have a question or need assistance with your appliance Try the GE Appliances Website 24 hours a day any day of the year For greater convenience and faster service you can now download Owner s Manuals order parts or even schedule service on line Schedule Service GEAppliances com Expert GE repair service is only one step away from your door Get on line and schedule your service at your convenience any day of the year Or call 800 GE CARES 800 432 2737 during normal business hours Real Life Design Studio GEAppliances com GE supports the Universal Design concept products services and environments that can be used by people of all ages sizes and capabilities We recognize the need to design for a wide range of physical and mental abilities and impairments For details of GE
Download Pdf Manuals
Related Search
Related Contents
Cashdata Manual Samsung 720N Instrukcja obsługi Comprehensive User`s Guide english V1.0 Lectures pragmatiques du texte de théâtre RÖMER LORD plus Istruzioni per l`uso Indice - Migros CT Coin Pelican User Manual COBLATION™ TURBINATOR™ 10.32Mb - Airborne Australia Viewsonic VFM1024W-11 digital photo frame Copyright © All rights reserved.
Failed to retrieve file