Hotpoint DSKS333ECWW Installation Instructions
Contents
1. length of 100 mm 4 dia rigid 8 A Bottom knockout 8 Rigid Metallic Ducting on rear exhaust model duct as shown remove burrs from cut edge e Attach this extension duct to blower housing e Seal all joints with duct tape Reinstall near access panel EXHAUST LENGTH CALCULATION RIGID Preferred Parts are available from your local service organization WX8X63 4 X1 Duct WX8Xx51 Elbow WxX8x64 4 X2 Duct WXx8Xx59 Aluminum hood RECOMMENDED MAXIMUM LENGTH Exhaust Hood Types Use only for short run installations Elbows Metal Metal 14 m 46 ft 11 m 37 ft i 2 3 11 m 37 ft 9 m 30 ft 9 m 30 ft 6 5 m 22 ft 7 m 23 ft 4 5 m 15 ft e For every extra 90 elbow reduce the allowable vent system length by 10 ft e Two 45 elbows will be treated like one 90 elbow e For the side exhaust installations add one 90 elbow to the chart e The total vent system length includes all the straight portions and elbows of the system transition duct included FLEXIBLE Total length of flexible metal duct shall not exceed 8 ft 2 4 m The following kit is available from you local service organization Kit WX08X10077 4 dia flexible metal serni rigid UL listed transition duct includes 2 elbows CONNECTING THE DRYER TO HOUSE VENT RIGID METAL TRANSITION DUCT e For best drying performance a rigid metal transition duct is recommended e Rigid metal transition ducts reduce
2. screw N of terminal block MINIMUM COPPER Hot Wire CONDUCTORS 30 AMP 240V TH TYPE UL PA ECOGNIZED MINIMUM RATED 90 C 208 OR 240 VOLT OPERATION 120 208 OR 120 240 VOLT SUPPLY USE ONLY 30 AMP FUSES FOR PERSONAL SAFETY THIS APPLIANCE MUST BE PROPERLY GROUNDED ite Neutral Wire e Properly strain relief the cordset or cable to the cable entry hole with UL recognized strain relief e Replace terminal block cover 3 WIRE RECEPTACLE 10 30R Typical 30 amp receptacle for use where local codes permit use of flexible type power supply cord pigtail This appliance must be grounded In the event of malfunction or breakdown grounding will reduce the risk of electric shock by providing a path of least resistance for electrical current AWARNING Improper connection of the equipment grounding conductor can result in a risk of electric shock Check with a qualified electrician or serviceman if you are in doubt as to whether the appliance is properly grounded Do not modify the plug provided with the appliance if it will not fit the outlet have a proper outlet installed by a qualified electrician AWARNING Appliance grounded to neutral conductor through a link If used in a mobile home a new construction a recreational vehicle or if local codes do not permit grounding through neutral a 4 conductor cord or cable assembly for use with clothes dryers must be used
3. ADA AND IN THE UNITED STATES THE REQUIRED EXHAUST DUCT DIAMETER IS 4 in 102mm DO NOT USE DUCT LONGER THAN SPECIFIED IN THE EXHAUST LENGTH TABLE Using exhaust longer than specified length will e Increase the drying times and the energy cost e Reduce the dryer life e Accumulate lint creating a potential fire hazard AAWARNING BEFORE PERFORMING THIS EXHAUST INSTALLATION BE SURE TO DISCONNECT THE DRYER FROM ITS ELECTRICAL SUPPLY The correct exhaust installation is YOUR RESPONSIBILITY Problems due to incorrect installation are not covered by the warranty Remove and discard existing plastic or metal foil transition duct and replace with UL listed transition duct The MAXIMUM ALLOWABLE duct length and number of bends of the exhaust system depends upon the type of duct number of turns the type of exhaust hood wall cap and all conditions noted below The maximum duct length for rigid metal duct is shown in the table on the next page EXHAUST SYSTEM CHECK LIST HOOD OR WALL CAP Terminate in a manner to prevent back drafts or entry of birds or other wildlife Termination should present minimal resistance to the exhaust air flow and should require little or no maintenance to prevent clogging Never install a screen in or over the exhaust duct This could cause lint build up Wall caps must be installed at least 12 in above ground level or any other obstruction with the opening pointed down SEPARATION OF TURNS For best p
4. Installation Instructions USA only MODELS DSKS433 AND DSKS333 MUST BE INSTALLED WITH CONTROL PANEL AT BOTTOM IN ORDER TO OPERATE ADEQUATELY BEFORE YOU BEGIN Read these instructions completely and carefully e IMPORTANT Save these instructions for local inspector s use e IMPORTANT Observe all governing codes and ordinances e Note to Installer Be sure to leave these instructions with the customer e Note to Customer Keep these instructions with your Owner s Manual for future reference e Before the old dryer is removed from service or discarded remove the dryer door e Service information and the wiring diagram are located in the control console e Do not allow children on or in the appliance Close supervision of children is necessary when the appliance is used near children e Install the dryer where the temperature is above 50 F for satisfactory operation of the dryer control system e Product failure due to improper installation is not covered under the Warranty e Dryers installed in garages if allowed by local codes must be elevated 18 inches 46 cm above the floor AWARNING RISK OF FIRE e To reduce the risk of severe injury or death follow all installation instructions e Clothes dryer installation must be performed by a qualified installer e Install the clothes dryer according to these instructions and in accordance with local codes In the absence of local codes installation must comply wi
5. T AND MOISTURE FROM ACCUMULATING AND TO MAINTAIN DRYER EFFICIENCY THIS MACHINE MUST BE EXHAUSTED OUTDOORS e Minimum clearances between dryer cabinet and adjacent walls or other surfaces are fete Sides e Minimum vertical space from floor to overhead cabinets ceiling etc is 52 in e Closet doors must be louvered or otherwise ventilated and must contain at least 60 square inches of open area equally distributed If the closet contains both a washer and a dryer doors must contain at least 120 square inches of open area equally distributed NOTE The clearances stated above are minimums Consideration must be given to the type accessory kit used with dryer Refer to the specific kit instruction for details UL LISTED FLEXIBLE METAL FOIL TYPE TRANSITION DUCT e In special installations it may be necessary to connect the dryer to the house vent using a flexible metal foil type duct A UL listed flexible metal foil type duct may be used ONLY in installations where rigid metal or flexible metal semi rigid ducting cannot be used AND where a 4 diameter can be maintained throughout the entire length of the transition duct e In Canada and the United States only the flexible metal foil type ducts that comply with the Outline for Clothes Dryer Transition Duct Subject 2158A shall be used e Never install flexible metal duct in walls ceilings floors or other enclosed spaces e Total length of flexible metal duct shoul
6. d not exceed 8 feet 2 4 m e Avoid resting the duct on sharp objects For best drying performance 1 Slide one end of the duct over the clothes dryer outlet pipe 2 Secure the duct with a clamp 3 With the dryer in its permanent position extend the duct to its full length Allow 2 of duct to overlap the exhaust pipe Cut off and remove excess duct Keep the duct as straight as possible for maximum airflow 4 Secure the duct to the exhaust pipe with the other clamp WHEN INSTALLED IN MANUFACTURED MOBILE HOMES Dryer must be exhausted to the outside Exhaust MUST NOT be terminated beneath mobile home Exhaust material MUST NOT support combustion Installation MUST conform to Manufactured Home Construction amp Safety Standard Title 24 CFR Part 32 80 or when such standard is not applicable the American National Standard of Mobile Homes ANSI NFRA No 5018 1977 For electrical connection see Connecting dryer using 4 wire connection USE OF CASTERS 120V PORTABLE MODELS ONLY For a portable installation screw casters into the holes on the bottom of the dryer Refer to the Installation Instructions for caster assembly sheet to install casters
7. ealed space of a building The accumulated lint could create a potential fire hazard e Never terminate the exhaust into a common duct with a kitchen exhaust system A combination of grease and lint creates a potential fire hazard e Do not use duct longer than specified in the exhaust length table Longer ducts can accumulate lint creating a potential fire hazard e Never install a screen in or over the exhaust duct This will cause lint to accumulate creating a potential fire hazard e Do not assemble ductwork with any fasteners that extend into the duct These fasteners can accumulate lint creating a potential fire hazard e Do not obstruct incoming or exhausted air e Provide an access for inspection and cleaning of the exhaust system especially at turns and joints Exhaust system shall be inspected and cleaned at least once a year ALTERNATE EXHAUST INSTRUCTIONS IF YOUR DRYER COMES WITH REAR EXHAUST TO CHANGE TO SIDE OR BOTTOM EXHAUST e Remove access panel at back of dryer to gain access to internal ducts e Disconnect duct exhaust from blower housing remove tape securing duct FOR SIDE EXHAUST e Remove desired knockout plate either right or left side e Cuta 115 mm 4 1 2 length of 100 mm 4 dia rigid duct as shown remove burrs from cut edge e Attach this extension duct to blower housing duct e Attach a 90 elbow facing desired opening e Attach a section of 100 mm 4 dia rigid duct to e
8. erformance separate all turns by at least 4 ft of straight duct including distance between last turn and exhaust hood TURNS OTHER THAN 90 e One turn of 45 or less may be ignored e Two 45 turns should be treated as one 90 turn e Each turn over 45 should be treated as one 90 turn SEALING OF JOINTS e All joints should be tight to avoid leaks The male end of each section of duct must point away from the dryer The duct shall not be assembled with screws or other fastening means that extend into the duct and catch lint Duct joints can be made air and moisture tight by wrapping the overlapped joints with duct tape Horizontal runs should slope down toward the outdoors 1 4 inch per foot INSULATION Ductwork that runs through an unheated area or is near air conditioning should be insulated to reduce condensation and lint build up EXHAUST CONNECTION AWARNING To REDUCE THE RISK OF FIRE OR PERSONAL INJURY e This clothes dryer must be exhausted to the outdoors e Use only 4 rigid metal ducting for the home exhaust duct e Use only 4 rigid metal or UL listed flexible metal semi rigid or foil type duct to connect the dryer to the home exhaust duct It must be installed in accordance with the instructions found in Connecting the Dryer to House Vent on page 4 of this manual e Do not terminate exhaust in a chimney a wall a ceiling gas vent crawl space attic under an enclosed floor or in any other conc
9. lbow to protrude through side of cabinet e Seal all joints with duct tape e Reinstall rear access panel FOR BOTTOM EXHAUST e Remove cover plate at bottom of dryer e Install a 90 elbow e Seal all joints with duct tape e Reinstall rear access panel e Place cover plate removed from bottom of dryer over rear exhaust opening VEE Front of dryer Right knockout 295mm 11 Cut Here EXTENSION DUCT cutting the exhaust duct DRYER TOP VIEW TO CHANGE TO SIDE OR REAR EXHAUST 6 Left knockout For Rear Exhaust yp Manon For Side Exhaust It is importat to replace the ground clip after IF YOUR DRYER COMES WITH TOP EXHAUST e Remove rear access panel e Disconnect retaining plate and 90 elbow by removing mounting screw from the chassis and remove tape securing elbow to blower housing e Remove cover plate from rear access panel and place over top exhaust opening FOR SIDE EXHAUST e Remove desired knockout plate either right or left side e Take the duct previously removed and cut a 115 mm 4 1 2 length of 100 mm 4 dia rigid duct as shown remove burrs from cut edge e Attach this extension duct to blower housing duct e Attach the 90 elbow facing desired opening e Attach a section of 100 mm 4 dia rigid duct to elbow to protrude through side of cabinet e Seal all joints with duct tape Reinstall rear access panel FOR REAR EXHAUST e Cut a 295 mm 11
10. rn dryer upside down as shown Olnstall knobs For location refer to the Owner s Manual O Dryer is now ready to be mounted above washer using accessory kit O Remove the foam shipping pads from under dryer O Move the dryer to the desired location O Follow the steps in the following pages to connect the dryer to the external exhaust and power supply Printed in Mexico 234D2017P001 31 16710 02 13 GE ELECTRICAL CONNECTION DETAILS OBSERVE ALL GOVERNING CODES AND ORDINANCES GROUNDING INSTRUCTIONS e The operating voltage Volts Amperage Amps and Frequency Hz of this dryer are indicated on the Rating Plate located to the right of the loading port e Connect this dryer to a circuit corresponding to that indicated on Rating Plate and protected by fuses or a circuit breaker in accordance with local codes e Use a power supply cord kit marked for use with clothes dryer For 208V and 240V models use a power supply cord kit marked for use with clothes dryers DO NOT USE EXTENSION CORD WITH THIS APPLIANCE For alternate 208V or 240V power supply hook up proceed as follows e Connect supply wire leads to terminal block as shown on sketch below depending on type of installation e Make sure screws on terminal block are tight FOR THREE WIRE SUPPLY 208V amp 240V MODELS e Remove terminal block cover e Connect two 2 HOT lines to outer screws L1 and L2 of a He 7 POWER SUPPLY e Connect i ne 7 om CORD 3 10 AWG
11. tallation 30 amps 120V installation 15 or 20 amps e The electrical installation must conform to the national and local codes 208V AND 240V MODELS ARE NOT APPROVED FOR 120V INSTALLATION TOOLS YOU WILL NEED SLIP JOINT PLIERS FLAT BLADE AND PHILLIPS SCREWDRIVERS METAL DUCT RECOMMENDED MATERIALS YOU WILL oes SAFETY DRYER POWER EXHAUST CORD KIT s DUCT HOOD GLASSES comer roviuclintenscernersetond 11 WIN owsa H ee O Over washer Use Wall Mount Kit WMK 35 or Stack Rack DSDR24 or Stack Rack DSR 24 OFor alcove and closet depth and width requirements see specific kit instructions DAII stacking kits are available from your local sales outlet UNPACKING AND PREPARING FOR INSTALLATION O Prepare the area and exhaust for installation of new dryer DIA FLEXIBLE METAL SEM RIGIO OR ZT Z ULRATED UL LISTED TRANSITION DUCT IF NEEDED 4 SPRING KIT WOBKIOO77 INCLUDES 2 ELBOWS 4 DIA FLEXIBLE METAL FIL TPE UL LISTED TRANSITION DUCT IF NEEDED i 3 4 STRAIN RELIEF ee WITH 3 OR 4 PRONGS POP METAL ULRECOGNIZED IDENTIFY THE PLUG TYPE AS PER THE HOUSE RECEPTACLE BEFORE PURCHASING LINE CORD CLAMPS 2 VG ELBOW DUCT TAPE O Check and ensure the existing external exhaust is clean and meets attached installation specifications O Remove the literature and accessories bag from the dryer drum Place the literature in a convenient place O Using foam pads from dryer carton tu
12. th the NATIONAL ELECTRICAL CODE ANSI NFPA NO 70 This dryer must be exhausted to the outdoors e Use only 4 rigid metal ducting for exhausting the clothes dryer to the outdoors e DO NOT install a clothes dryer with flexible plastic ducting materials If flexible metal semi rigid or foil type duct is installed it must be UL listed and installed in accordance with the instructions found in Connecting The Dryer To House Vent on page 4 of this manual Flexible venting materials are known to collapse be easily crushed and trap lint These conditions will obstruct dryer airflow and increase the risk of fire e Do not install or store this appliance in any location where it could be exposed to water and or weather e Save these instructions Installers Be sure to leave these instructions with the customer DETERMINE ELECTRICAL REQUIREMENTS FOR YOUR DRYER MODEL e This dryer must be connected to an individual branch circuit of proper voltage and frequency as specified on Rating Plate located inside dryer door with no other appliances or fixtures attached EXCEPTION e A 120V receptacle is located on the back on the dryer and is available only for use with a washer that is affixed to the dryer with a WDF 85 kit It may not be used for any other appliance or any conditions other than stated above 208V amp 240V models only e Branch circuit must be protected by the required time delay fuses or circuit breakers 208V or 240V ins
13. the risk of crushing and kinking UL LISTED FLEXIBLE METAL SEMI RIGID TRANSITION DUCT e If rigid metal duct cannot be used then UL listed flexible met al semi rigid ducting can be used Kit WX08X10077 e Never install flexible metal duct in walls ceilings floors or other enclosed spaces e Total length of flexible metal duct should not exceed 8 feet 2 4 m e For many applications installing elbows at both the dryer and the wall is highly recommended see illustrations below Elbows allow the dryer to sit close to the wall without kinking and or crushing the transition duct maximizing drying performance e Avoid resting the duct on sharp objects NOTE TO INSTALLER AFTER INSTALLATION CHECK THE FOLLOWING O EXHAUST DUCT Must meet specs on page 3 No excessive turns No kinks or obstructions to air flow O EXHAUST HOOD Should work freely and open downward O GROUNDING Dryer must be properly grounded to conform to local codes and ordinance requirements O OPERATION Turn dryer on and check for heat O HAND CUSTOMER THE OWNER S MANUAL Give instructions on operating the dryer Answer any questions O GIVE THESE INSTALLATION INSTRUCTIONS to the customer ALCOVE OR CLOSET INSTALLATION e lf your dryer is approved for installation in an alcove or closet it will be stated on a label on the dryer back The installation must conform to the following specifications AAWARNING to prevent LARGE AMOUNTS OF LIN
14. with the following specifications Type St Cable 125 250 Min Volt 30 Amp with closed loop terminals and secured with a UL recognized strain relief See manufacturer s instructions FOR FOUR WIRE SUPPLY 208V amp 240V MODELS e Remove terminal block cover e Remove ground strap and discard Re screw green grounding screw in place e Connect two 2 HOT lines to outer screws L1 and L2 of terminal block e Connect Neutral line to center screw N of terminal block e Attach ground wire of power supply to green grounding screw beside terminal block Green Grounding Screw POWER SUPPLY CORD 4 10 AWG MINIMUM COPPER CONDUCTORS 30 AMP 240V WITH CLOSED LOOP TERMINALS TYPE UL RECOGNIZED MINIMUM RATED 90 C Aww REMOVE GROUND STRAP AND DISCARD 208 OR 240 VOLT OPERATION 120 208 OR 120 240 VOLT SUPPLY USE White Neutral Wire ONLY 30 AMP FUSES FOR PERSONAL SAFETY THIS APPLIANCE MUST BE PROPERLY GROUNDED e Properly strain relief the cordset or cable to the cable entry hole with UL recognized strain relief e Replace terminal block cover cut al 4 CONDUCTOR CORD ASSEMBLY Type ST Cable Typical 30 amp cord assembly for use where local codes do not permit grounding through neutral Green or Yellow Ground Wire 4 WIRE RECEPTACLE 14 30R Typical 30 amp receptacle for use where local codes permit use of flexible type power supply cord pigtail EXHAUST INFORMATION AAWARNING IN CAN