1. UserID and Password 2 Click on the Device Overview tab to access the Device List for the system Once you are at the Device List click on the Settings icon for the HoneywellAlarmPanel to the right of the Device List LIVE VIDEO fe VERY EVENT ARCHIVE ACCOUNT SETTINGS Device List Scene Home _Away Refresh Control Name Pan Tilt Camera Disarmed DISARMED HoneywellAlarmPanel 7317 Ready to Arm DEVICE OVERVIEW PAGE 3 Send a test command through the Virtual Keypad to disarm the system and the status of the panel will appear Settings HoneywellAlarmPanel 7317 HoneywellAlarmPanel 7317 E r sw 15 nest 6 E Zone Name Partition Input ADD NEW APPLY CHANGES CANCEL 4 In the User Code field on the pop up the customer will enter a User Access Code for the RANGE TEST alarm system Please note that this step is not required for manual operations Perform this test if the LED indicator on the Honeywell Bridge continuously This will enable the customer to set up Rules through the Security Wizard in their web account shows solid RED and does not change to GREEN Until the customer completes this step the XG1000 Controller will NOT be able to Arm Disarm the panel as part of a Rule Schedule or through the quick ARM DISARM buttons at the top of Honeywell Bridge you will need to quickly press and Me Mavice ist pap release the RANGE TES
2. Remote HONEYWELL BRIDGE INSTALLATION PROCEDURE HONEYWELL VISTA SERIES 15P amp 20P AND SAFEWATCH 3000 ADDRESSABLE PANELS ONLY PROFESSIONAL INSTALLATION OF THE BRIDGE TO THE ALARM PANEL IS RECOMMENDED My Honeywell Alarm Panel ARMED READY away stay TEST BYPASS INSTANTS cope CHIME READY INSTALLATION CHECKLIST XG1000 Controller and a Honeywell Bridge 6160 Alpha panel as a debugging tool Confirm address 22 is open and configured as a keypad device Please note that if 22 15 already is use the existing keypad will need to be moved to a different address Remote account username and password INSTALL amp VALIDATE XG1000 CONTROLLER 1 Locate the customer s external internet connection and the in home router Find one unused LAN RJ 45 port on the router Then use an Ethernet cable to connect the LAN RJ45 port on the XG1000 Controller to the unused LAN RJ45 port on the router XG1000 CONTROLLER gt ROUTER DSL CABLE MODEM gt INTERNET NOT INCLUDED NOT INCLUDED 2 Connect XG1000 Controller to power and verify the following m The XG1000 X power LED is lighted BLUE lf the power LED is not lighted please re check all power connections see Troubleshooting Section The XG1000 LAN Link LED is lighted GREEN lf the LAN Link LED does not light check the Ethernet connection and or try using a different Ethernet cable see Trouble
3. T button on the front panel of NOTE The user enters user code whenever they manually issue a command to arm disarm from the XG1000 Controller see diagram The left LED 2288 09 their Virtual Keypad in their web account just as they would if they were standing in front of their next to the ACT LED will turn GREEN when the test f keypad in their home has begun If the range test LED does not turn on try 2 pressing the button one of two more times until it does z z 9 Select the email SMS addresses that you would like to receive Alarm Notifications wait at least 15 seconds between button presses a if the address does not already appear in the list click the Add New button and Do NOT proceed until the range test LED has turned on 5 camera you would like to exclude from capturing video in the event of an Alarm Condition and is GREEN CCO E AREE E RANES SANE your SHUNDE 2 Go to the Honeywell Bridge and view the LED on the front it You must also go into programming and disable the Auto Stay function on the Alarm Panel otherwise if the alarm is set to Arm Away mode and the exit door is not opened the Alarm Panel will automatically go to Arm Stay mode TROUBLESHOOTING lf you are having trouble operating this product please consult the guide below PROBLEM SOLUTION XG1000 Controller 1 Check that XG1000 is connected to power X Blue power LED 2 Check all pow
4. er cables are firmly connected does not light up The XG1000 1 Check that the Ethernet cable connecting the XG1000 Controller to Controller the Router is firmly connected LAN Link LED 2 Iry another Ethernet cable is not Green Honeywell Bridge 1 Check connections the bridge is not receiving power LED does not light up should be flashing ORANGE about once a second If it is not flashing at all or is flashing very Slowly i e once every five seconds or if the LED is solid RED or GREEN the range test is failing and you will need to locate the Honeywell Bridge closer to the XG1000 Controller You can do this by extending the wire to the Bridge device just like you would for a Honeywell Panel The range test automatically shuts off after 5 minutes To start the range test running again push the RANGE TEST button 3 To finish the Range Test quickly press and release the RANGE TEST button again on the front panel of the XG1000 Controller The range test LED will turn off After the range test is complete the LED on the Honeywell Bridge should be GREEN
5. ge is not receiving power please check all connections see Troubleshooting Section lf the LED changes from solid GREEN to solid RED within the first 60 seconds after applying power and remains solid RED the Controller and the Bridge may be having difficulty communicating Please perform the Range Test described in the Troubleshooting Section of this manual 4 Go to existing alarm keypad Disarm the alarm system establish access to alarm system via the Installer Code may need to re power unit and use to set an installer code 5 Connect a 6160 ALPHA KEYPAD if existing keypad is not alpha From the keypad enable the keypad address 22 in the alarm panel for use by the Honeywell Bridge for the SafeWatch Pro 3000 enter 1 0 T in location 195 5 Log into your remote account via a PC browser Click on the Account Settings tab on the interface and then select the Discovery sub tab to access the Discovery page NOTE If your XG1000 Controller is not registered to your account you must register it prior to proceeding LIVE VIDEO DEVICE OVERVIEW EVENT ARCHIVE MIS J Discovery XG1000 Controller Start Discovery DEVICE DISCOVERY PAGE On the Discovery page click on the START DISCOVERY button to start the Bridge registration process When the page heading indicates that discovery is in process press the DISCOVERY ee button on the lower left corner of the Honeywell Bridge device as sh
6. own LIVE VIDEO DEVICE OVERVIEW EVENT ARCHIVE ling Discovery G1000 Controller Stop Discovery Discovery in progress Press discovery button on all wireless devices one at a time you want to register with your gateway Click on Stop Discovery button when done or gateway will stop discovery automatically 15 after discovery started Control Name C Pan Tilt Camera DEVICE DISCOVERY IN PROGRESS When the Discovery process has finished for the Honeywell Bridge it will appear on the list of your devices on the Discovery page and the LED on the Honeywell Bridge should turn GREEN At this point you may press the STOP DISCOVERY button to stop the Discovery process LIVE VIDEO DEVICE OVERVIEW EVENT ARCHIVE Discovery X G1000 Controller Stop Discovery Discovery in progress Press discovery button on all wireless devices one at a time you want to register with your gateway Click on Stop Discovery button when done or gateway will stop discovery automatically 15 after discovery started Found new device sn 7317 Control Name Pan Tilt Camera HoneywellAlarmPanel 7317 HONEYWELL ALARM PANEL DISCOVERED After the system has registered the Honeywell Bridge device go to the Device Overview page and verify that the Honeywell Bridge device was properly discovered COMPLETING THE INSTALLATION 1 Access your remote account via a PC browser and log in using your account
7. shooting Section 3 Wait up to 3 minutes for the XG1000 Controller to initialize 4 Check and confirm LED marked REM is solid GREEN REM LED is the health indicator for remote access LAN LINK POWER gt gt Lu HONEYWELL BRIDGE INSTALLATION PROCEDURE 1 Connect the Honeywell Bridge to the Honeywell Panel or the keypad if possible The Bridge connects just like an additional keypad SafeWatch Pro 3000 terminals noted Please power down the Honeywell Panel prior to beginning this process Black wire to Pin 4 Red wire to Pin 5 HONEYWELL BRIDGE Green wire to Pin 6 Yellow wire to Pin SAFEWATCH PRO 3000 CONTROL TERMINAL STRIP AUX AUX DATA DATA WN OUT 4 5 6 7 x x x x Eee 2 TO KEYPAD BLK WIRE BRIDGE YEL WIRE TO KEYPAD RED WIRE BRIDGE GRN WIRE TO KEYPAD GRN WIRE 4 BRIDGE RED WIRE 1 BRIDGE BLK WIRE TO KEYPAD YEL WIRE 1111 NOTE The existing keypad will remain connected Mount the Bridge device near the alarm panel away from large metal objects If necessary you can extend the length of the wire using four conductor cable and wire nuts For best results the bridge device should be mounted as high as possible preferably at least 6 feet above the floor 2 Re connect power to the Honeywell Panel 3 The LED on the Honeywell Bridge should light up and display RED If the LED does not light up the Brid