1. the monitor at another location modify the procedure to fit the installation 1 2 a i Hold the mounting template included in the W8600F kit next to the T8600 as shown in Fig 3 Mark the holes for the screw anchors and the 3 conductor thermostat cable Remove the template and drill the holes Remove the W8600F from the base Position the W8600F base over the holes and install the anchors and screws included in the bag assembly Tighten the screws until the base is mounted firmly on the wall 69 1200 2 THERMOSTAT See a WALLPLATE M11971 Q was WIRING HOLE MOUNTING HOLES 2 Fig 3 Positioning mounting template W8600F AIR CLEANER MONITOR Wash Fr n 3 Check that the battery is correctly installed in the Select Was pelea cy l W8600F battery holder Use the W8600F DIP switches to program the time 4 Snap the W8600F onto the base between SERVICE indications Be sure to select the 5 Turn off the power for the EAC setting according to the conditions of the home Factors to consider include the duty cycle of the EAC the number of people and pets and activities such as A woodworking and other crafts that are being done in the WARN l NG home Electric Shock Hazard Can cause electrical shock or equipment Refer to Table 2 to select the wash frequency Set the damage WB8600F DIP switches to match the selection See Fig 4 Disconnect EAC power and open the access The time listed represents act
2. Honeywell W8600F Air Cleaner Monitor APPLICATION The W8600F Air Cleaner Monitor is an option available for use with the F50F and F52F Honeywell Electronic Air Cleaners EAC The series two F50F and F52F require a solid state power supply that is compatible with the W8600F driver board Any series one F50E F or F52F can be upgraded to use the W8600F when the power supply is replaced and the driver board included in W8600F kit is installed The W8600F function indicator panel has four liquid crystal display LCD arrowheads that point to ON BATTERY SERVICE or FAULT See Fig 1 The arrowheads darken to indicate the existing EAC condition See Table 1 INSTALLATION viel Installing this Product Read these instructions carefully Failure to follow the instructions could damage the product or cause a hazardous condition 2 Check the ratings given in the instructions and on the product to make sure the product is suitable for your application 3 Installer must be a trained experienced service technician 4 After completing the installation use these instruc tions to check out the product operation Location The styling of the W8600F is designed to blend with the latest T8600 family of Honeywell Chronotherm IV Deluxe Programmable Thermostats A special mounting template is included for mounting next to the T8600 The W8600F can also be mounted at any other convenient location in the living area or equipment room S
3. ee Fig 2 NOTE The W8600F shares no common electrical con nections with the thermostat U S Registered Trademark Copyright 2002 Honeywell International In H INSTALLATION INSTRUCTIONS a m UN BATTERY SERVICE FUNCTION Air Cleaner Monitor INDICATOR PANEL RESET BUTTON M11965 Fig 1 W8600F Air Cleaner Monitor features Table 1 Description of W8600F Function Indicator Panel Indicators Condition ON EAC is powered and system blower is running BATTERY Battery that maintains W8600F memory is low and needs to be replaced SERVICE EAC prefilter and cells need to be washed FAULT Shorting of collector plates Continuous ionizer or collector plate arcing Power supply failure Excessive current Major reduction in high voltage EAC prefilter and cells are past SERVICE level of dirt and need to be washed immediately Call a service technician a The reset button is located on the bottom of W8600F After the prefilters and cells are cleaned and reinstalled press this button to turn off the SERVICE indicator and reset the wash frequency timer 69 1200 2 W8600F AIR CLEANER MONITOR F52 ATTIC RETURN AIR DUCT CEMENT BLOCK WALL CLOSET GARAGE DRYWALL M11966 Fig 2 W8600F mounting locations Mounting The following mounting instructions assume that the W8600F is mounted next to a T8600 Thermostat If installing
4. icates ON FAULT will turn off Remove 9 Vdc input The W8600 is functional TROUBLESHOOTING cated Refer to Table 3 Table 3 W8600F Troubleshooting Information Display Condition Solution Blank EAC is not operating Turn on EAC Function panel indicates ON Press W8600F reset button DISPLAY flashes five times ON indicator does not flash when reset button is pressed Check W8600F battery for 2 7 volts Replace with BR2032 lithium battery if necessary All four indicators flash after pressing reset button but ON is not displayed Power supply does not have an airflow switch Assemble jumper on pins 1 and 2 of J3 connector on power supply with EAC operation Voltage between W8600F terminals 1 ground and 4 10 to 15 Vdc Replace W8600F No voltage low voltage or wrong polarity Check wiring between W8600F and EAC Correct wiring if necessary No voltage between EAC terminals 1 ground and 4 10 to 15 Vdc Check the driver board and cable installation Correct installation if necessary BATTERY SERVICE or FAULT but not ON Incorrectly wired Check wiring between W8600F and EAC Correct wiring if necessary ON and BATTERY Bad battery Check W8600F battery for 2 7 volts Replace with BR2032 lithium battery if necessary ON and SERVICE EAC cells and prefilters are dirty Wash and reinstall the EAC cells and prefilters Press the W8600F rese
5. ing shorting bar on power supply for damage due to static electricity applications without AFS 2 Connect the wires to terminals E1 E3 and E4 on 11 Replace the power supply box cover the W8600F See Fig 4 3 69 1200 2 W8600F AIR CLEANER MONITOR 12 Connect the three wires from the W8600F to the EAC terminals 1 3 and 4 NOTE Connect terminal 1 to 1 3 to 3 and 4 to 4 13 14 15 Turn on the system fan Turn on the EAC power Connect terminal 3 to terminal 4 and the function panel indicates ON FAULT will turn off Disconnect terminal 3 from terminal 4 The W8600F is functional PIOC TOU Without EAC Push the W8600F reset button All four indicators on the display will flash five times The On indicator will stay active as long as the EAC and the system fan are on SYSTEM CHECKOUT Checkout With EAC Running 1 Be sure the battery is installed in the W8600F 2 Press the reset button on bottom of the W8600F All four indicatiors on the display will flash five times and then ON and FAULT will remain indi Be sure the battery is installed in the W8600F Press the reset button on the bottom of the W8600F All four indicators on the display will flash five times then ON and FAULT will remain indi cated Connect 9 Vdc to terminal 4 with terminal 1 as ground use a 9 volt transistor battery The func tion panel indicates ON and FAULT Connect terminal 3 to terminal 4 and the function panel ind
6. t button ON flashes five times and SERVICE is off ON and FAULT Damaged cells Repair or replace cells Power supply problem Press EAC test button and verify output voltage Replace power supply if necessary Automation and Control Solutions Honeywell International Inc 1985 Douglas Drive North Golden Valley MN 55422 Honeywell Limited Honeywell Limit e 35 Dynamic Drive Scarborough Ontario MIV 429 69 1200 2 G H Rev 12 02 Printed in U S A on recycled amp paper containing at least 10 Honeywell www honeywell com post consumer paper fibers
7. ual run time of the EAC not door before opening power supply box cover calendar days 6 Open the power supply box cover Table 2 Wash Frequency Options 7 Remove the plug from the side of the power supply m box plug can be a metal knockout or a blank termi DIP Switch Settings Wash Frequency nal strip 8 Install the terminal block cable assembly supplied Days Run Time with W8600F kit 9 Plug the connector on the end of the cable assem bly into the J2 terminal on the driver board included with W8600F kit See Fig 5 POWER SUPPLY BOX COVER Gy BACK OF W8600F TERMINAL STRIP BATTERY MOUNTING IN HOLDER SCREW DIP SWITCHES SUPPLY ee POWER SUPPLY BOX WIRING TERMINALS 3 M11970 Fig 5 Installing the driver board on the EAC 10 Plug the driver board assembly into the J1 power RESET BUTTON supply connector M11969A NOTE This W8600F kit is configured to operate with a power supply that is controlled by an airflow switch AFS If your application does not have an AFS place the black shorting bar found in Wiring the bag assembly on power supply connector J3 pins 1 and 2 as shown in Fig 6 Fig 4 Back of W8600F 1 Run a 3 conductor thermostat cable up to 18 gauge from the W8600F to the terminal strip on the air cleaner SHORTING BAR J3 M20890 IMPORTANT Connect cable to W8600F before attaching to the air cleaner terminals to minimize the risk of Fig 6 Plac