        Honeywell VISIONPRO TH8110U User's Manual
         Contents
1.         Wire hole Mounting screws                Wall anchors    MCR29481    Must be installed by a trained  experienced technician    e Read these instructions carefully  Failure to follow these instructions  can damage the product or cause a hazardous condition     1 CAUTION  ELECTRICAL HAZARD    Can cause electrical shock or equipment damage  Disconnect power before  beginning installation     MERCURY NOTICE   A If this product is replacing a control that contains mercury in a sealed tube  do not  place the old control in the trash  Contact your local waste management authority for  instructions regarding recycling and proper disposal     69 2693   01 2    VisionPRO    TH8000 Series          Power options       HEAT PUMP  CONVENTIONA                              MCR29482          For 24VAC primary power  connect common Insert supplied batteries for   side of transformer to    C    terminal  primary or backup power    Remove factory installed jumper Push excess wire back into the wall opening  Plug  only for two transformer systems  wall opening with non flammable insulation     HEAT PUMP     s                                                                   MCR29483    Terminal Designations shaded areas below apply only to TH8320 TH8321     Conventional Terminal Letters  Heat Pump Terminal Letters    R Heating power  Connect to secondary R Heating power  Connect to secondary  side of heating system transformer  side of heating system transformer    Re Cooling power  Conne
2.    Heat Only System    Heat Only System With Fan                   Re Power  1  Re Power  1    R  R Rc joined by jumper  R  R Rc joined by jumper    WwW Heat relay Ww Heat relay   c 24VAC common  3  G Fan relay   S1 Optional outdoor remote sensor c 24VAC common  3    S2 Optional outdoor remote sensor S1 Optional outdoor remote sensor       Heat Only System  Series 20     S2 Optional outdoor remote sensor                         Re  R Rc joined by jumper  Cool Only System   R Series 20 valve terminal    R     1  Rc Power  1    w Series 20 valve terminal    B    R  R Rc joined by jumper    Y Series 20 valve terminal    W    Y Compressor contactor   c 24VAC common  3  G Fan relay   S1 Optional outdoor remote sensor c 24VAC common  3    S2 Optional outdoor remote sensor S1 Optional outdoor remote sensor       2H 2C System  1 transformer     S2 Optional outdoor remote sensor                                     Y2 Cool relay 2 2H 2C System  2 transformers    w2 Heat relay 2 Y2 Cool relay 2   Re Power  1  W2 Heat relay 2   R  R Rc joined by jumper  Re Power  cooling transformer   1  2    w Heat relay 1 R Power  heating transformer   1  2    Y Cool relay 1 Ww Heat relay 1   G Fan relay Y Cool relay 1   c 24VAC common  3  G Fan relay   S1 Optional outdoor remote sensor Cc 24VAC common  3  4     2 Optional outdoor remote sensor S1 Optional outdoor remote sensor  S2 Optional outdoor remote sensor       See  notes  below   1  Power supply  Provide disconnect means and overload protection
3.   10  11  12 CPH     Backlight on for approx  8 seconds after keypress  Backlight always on low intensity  full bright after key   press  requires 24VAC connection     Manual changeover  Heat Cool Off   Automatic changeover  Heat Cool Auto Off     Heat cool temperature 3  F apart  1 5  C     See page 11   Other options  2 9  2  F to 9  F 1 5   C to 5  C      Fahrenheit  Celsius    Auto change to daylight savings time  2007 and be   yond  for areas that use the new 2007 DST calendar   Auto change to daylight savings time  through 2006  and  for areas that do not use the new 2007 DST calendar   Daylight savings time is turned off    No remote sensor   Outdoor sensor  display only    Outdoor control sensor  select heat pumps     See page 11  Indoor sensor    No heat pump compressor lockout    Other options  15  20  25  30  35  40  F   9 5  C to 7  C    No heat pump auxiliary lockout    Other options  40  45  50  55  60  F  4 5  C to 15 5  C      No dehumidification control  Thermostat controls dehumidification with air conditioner     See page 11    Continued on next page    VisionPRO    TH8000 Series       Installer setup  Setup functions Settings  amp  Options  factory default in bold     0500    0510    0520    0530    0540    0580    0600    0610    0640    0650    0660    0670    0680    0690    0700    0710    Furnace filter  change reminder    Humidifier pad  change reminder    UV lamp change  reminder    Adaptive Intelligent  Recovery       Program periods    Compressor 
4.   Honeywell    Installation  Guide       VisionPRO   TH8000 Series    Touch screen Programmable Thermostat    This manual covers the following models  e TH8110U  For 1 Heat 1 Cool systems  e TH8320U  For up to 3 Heat 2 Cool systems  e 1TH8321U  For up to 3 Heat 2 Cool systems with dehumidification   Pull thermostat from wallplate and turn over to find model number     System Types e Heat only     two wire systems   power to open and close zone  valves  Series 20   and normally  open zone valves    e Gas  oil  or electric heat with air  conditioning  e Warm air  hot water   highefficiency furnaces  heat  pumps  steam  gravity e Cool only  e 750 mV heating systems    e Heat only with fan    This thermostat contains a Lithium battery which may contain Perchlorate material   Perchlorate Material   special handling may apply   See www dtsc ca gov hazardouswaste perchlorate    Need Help     For assistance with this product please visit http   customer honeywell com  or call Honeywell Customer Care toll free at 1 800 468 1502       U S  Registered Trademark   Copyright    2012 Honeywell International Inc     All rights reserved  69 2693 01    HSIT9N3    Installation Guide    Walliplate installation    1  Separate wallplate from thermostat  Grasp top and bottom of wallplate  and pull to remove from thermostat        2  Mount wallplate as shown below                                         Drill 3 16    holes for drywall   Drill 7 32    holes for plaster                       MCR29480
5.  as required    2  Remove jumper for 2 transformer systems    3  Optional 24VAC common connection    4  Common connection must come from cooling transformer     69 2693   01 4    VisionPRO    TH8000 Series             Wiring guide   heat pump systems  Shaded areas below apply only to TH8320 TH8321   1H 1C Heat Pump  no auxiliary heat        2H 2C Heat Pump  no auxiliary heat                                                  Re Power  1  Y2 Compressor 2 relay   R  R Rc joined by jumper  Re Power  1    O B Changeover valve  5  R  R Rc joined by jumper    Y Compressor relay O B Changeover valve  5    G Fan relay Y Compressor 1 relay   c 24VAC common  3  G Fan relay   S1 Optional outdoor remote sensor Cc 24VAC common  3    S2 Optional outdoor remote sensor S1 Optional outdoor remote sensor  S2 Optional outdoor remote sensor    2H 1C Heat Pump  with auxiliary heat                                                                    L Equipment monitor  6  7  3H 2C Heat Pump  with auxiliary heat   Aux E Auxiliary Emergency heat relay  Heat 2  Y2 Compressor 2 relay  Re 3 Power  1  L Equipment monitor  6  7   R  R Rc joined by jumper  Aux E Auxiliary Emergency heat relay  Heat 2   O B Changeover valve  5  Re Power  1   Y Compressor relay R  R Rc joined by jumper   G Fan relay O B_ Changeover valve  5   c 24VAC common  3  Y Compressor 1 relay  S1 Optional outdoor remote sensor G Fan relay  S2 Optional outdoor remote sensor Cc 24VAC common  3   S1 Optional outdoor remote sensor  S2 Option
6.  protection    Heat temperature  range stop    Cool temperature  range stop    Clock format    Extended fan  timer  heat     Extended fan  timer  cool     Keypad lock    Heat temperature  control    Cool temperature  control    Temperature  display offset    RESET    a oh Ost  O WHO DUHAWNDHO    12    N  A        go        go    O UAN OAN NO    e         off   10 day run time  about 1 month   30 day run time  about 3 months   60 day run time  about 6 months   90 day run time  about 9 months   120 day run time  about 1 year   365 day run time  about 3 years     Off   90 calendar days  180 calendar days  365 calendar days    Off  365 calendar days    On   See page 11  Off    4 program periods  Wake  Leave  Return  Sleep   2 program periods  Wake  Sleep     5 minute compressor off time    See page 11   Other options  0  1  2  3 or 4 minute off time     Max  heat temperature setting is 90  F  32  C    Other options  40 89  F  4 5  C to 32  C      Min  cool temperature setting is 50  F  10  C    Other options  51 99  F  10 5  C to 37  C      12 hour time  i e      3 30 pm      24 hour time  i e      15 30        Off  Fan runs for 90 seconds after call for heat ends    Off  Fan runs for 90 seconds after call for cooling ends    Keypad unlocked  fully functional   Partially locked  access to temperature settings only   Fully locked    Standard temperature control  recommended   Choose if room is warmer than set temperature  Choose if room does not reach set temperature    Standard t
7. Settings  amp  Options  factory default in bold     Shaded areas below apply only to TH8320 TH8321     0120    0130    0140  0150  0160    0170    0180    0190    0200    0210    0220    0230    Year   first two digits     Year   second two digits     Month  Date  Schedule format    System type    Fan control   heating     Changeover valve   O B terminal     Auxiliary heat    External fossil  fuel kit    1st stage com   pressor cycle rate    2nd stage com   pressor cycle rate    20  21    12    6        oa    ahon s Of    U om 20O 20 20    a     2001 2099    2100 2178      2012      Other options  00 99      Other options  1 12    Other options  1 31     7 day programming  Non programmable       1 heat 1 cool conventional  1 heat 1 cool heat pump  no aux  heat     Heat only  2 wire systems     Heat only with fan    Hot water Series 20 system  power to open  amp  close zone  valves normally open zone valves     Cool only    2 heat 1 cool heat pump  with aux  heat   2 heat 2 cool multistage conventional   2 heat 1 cool multistage conventional   1 heat 2 cool multistage conventional   2 heat 2 cool heat pump  no aux  heat   3 heat 2 cool heat pump  with aux  heat     Gas Oil heat  equipment controls heating fan   Electric furnace  thermostat controls heating fan     O B terminal controls valve in cooling  O B terminal controls valve in heating    Electric backup heat  Fossil fuel backup heat    External fossil fuel kit controls backup heat  Thermostat controls backup heat  outdo
8. Shaded areas below apply only to TH8320 TH8321           Auto Changeover  Setup Function 0300   When set to Auto  the thermostat automatically selects  heating or cooling depending on the indoor temperature  Heat and cool settings must be at least 2 de   grees apart  If function 0380 is set to On  the heat and cool settings must be at least 5 degrees apart     Remote Sensor  Setup Function 0340   If an optional outdoor sensor is installed  the thermostat can  display the outside temperature  If an optional remote indoor sensor is installed  the thermostat will  display the temperature at the sensor location  the internal sensor in the thermostat is not used      Adaptive Intelligent Recovery  Setup Function 0530   Allows the thermostat to    learn    how long the  furnace and air conditioner take to reach programmed temperature settings  so the temperature is  reached at the scheduled time     Compressor Protection  Setup Function 0580   Forces the compressor to wait a few minutes before  restarting  to prevent damage  During this time  the message    Wait    flashes on the display     Dehumidification control  Setup Function 0380   TH8321 models monitor the indoor humidity level  and automatically activate the cooling system to reduce humidity by lowering the temperature by up  to 3 degrees below the current cool setting     Heat Pump Temperature Lockout  with fossil fuel backup   If the thermostat is installed with an  optional outdoor sensor  you can select a compressor lo
9. al outdoor remote sensor    See  notes  below   1  Power supply  Provide disconnect means and overload protection as required    3  Optional 24VAC common connection    5  O B set to control as either O or B in installer setup    6  If L terminal is used  24VAC common  terminal C  must be connected      7  Heat pump reset  powered continuously when thermostat is set to Em  Heat  system monitor  when set to Heat  Cool  or Off            69 2693   01    HSIT9N4    HSIT9N3    Installation Guide       Remove tab and mount thermostat    Remove tab        Align pins on back of thermostat with  slots in wallplate  then push gently  until thermostat snaps into place                           MCR29484     Set date and time    Press AW  to set date    Press AW    to set month i 5  Press AW    to set year         Press DONE to save changes     TUE    z3  cule ivi 5       Press AW  to set time We       LJ                   MCR29485    Press DONE to save and exit     Installer setup    1  Press SYSTEM     TUE    Inside  AUTO          jaa   TI    BL 8    AR    SCHED    HOLD       69 2693   01    2     Press and hold  stew   these two buttons   until the display   changes           Change settings  as required  see  pages 7 9       4   a  Sea    MCR29486    died          VisionPRO    TH8000 Series       Installer setup    Function    Setting          Press AW to  select function    Press AW to  change setting             MCR29486    Press DONE to exit  amp  save settings     Setup functions 
10. ckout temperature  Function 0350   When  the outdoor temperature is below the lockout temperature  only the auxiliary heat operates  When the  outdoor temperature is above the lockout temperature  only the compressor operates     Heat Pump Temperature Lockouts  with electric heat backup   If the thermostat is installed with  an optional outdoor sensor  you can select a compressor lockout temperature  Function 0350  and   or an auxiliary heat lockout temperature  Function 0360   When the outdoor temperature is below the  compressor lockout temperature  only the auxiliary heat operates  When the outdoor temperature is  above the auxiliary lockout temperature  only the compressor operates  If the outdoor temperature is  between the compressor and auxiliary lockout temperatures  both the compressor and auxiliary heat  can operate     Accessories  amp  replacement parts    Please contact your distributor to order replacement parts   Outdoor temperature sensor      Part Number C7089U1006  Remote indoor temperature sensor   Part Number C7189U1005  Cover plate  A      Part Number 32003796 001    Use to cover marks left by old thermostats                11 69 2693   01    HSIT9NA    Installation Guide       Specifications    Temperature Ranges Electrical Ratings    dese N to x     4 5 oe C  Terminal Voltage  50 60Hz   e g o o o o   Cook S0 ee MOto SC a Heating 20 30 Vac  Operating Ambient Temperature  Powerpile  750 mV DC  e 0   to 120  F   18   to 48 9  C  W2 Heating 20 30 Vac  Shipp
11. ct to secondary Re Cooling power  Connect to secondary  side of cooling system transformer  side of cooling system transformer    C Common wire from secondary side of c Common wire from secondary side of  cooling transformer  if 2 transformers   cooling system transformer    W 1st stage heat relay  Y 1st stage compressor contactor    W2 2nd stage heat relay  Y2 2nd stage compressor contactor    Y 1st stage compressor contactor  Aux E Auxiliary Emergency heat relay    Y2 2nd stage compressor contactor  G Fan relay    G Fan relay  L Heat pump reset  powered continuously   S1 Optional outdoor or remote sensor  when System is set to Em Heat  system   S2 Optional outdoor or remote sensor  monitor when set to Heat  Cool or Off      O B Changeover valve for heat pumps   S1 Optional outdoor or remote sensor   S2 Optional outdoor or remote sensor     3 69 2693   01    HSIT9N4    Installation Guide       Wiring guide   conventional systems  Shaded areas below apply only to TH8320 TH8321   1H 1C System  1 transformer        1H 1C System  2 transformers     HSIT9N4                         Re Power  1  Re Power  cooling transformer   1  2   R  R Rc joined by jumper  R Power  heating transformer   1  2   WwW Heat relay Ww Heat relay   Y Compressor contactor Y Compressor contactor   G Fan relay G Fan relay    e 24VAC common  3  Cc 24VAC common  3  4     1 Optional outdoor remote sensor S1 Optional outdoor remote sensor  S2 Optional outdoor remote sensor S2 Optional outdoor remote sensor    
12. emperature control  recommended   Choose if room is cooler than set temperature  Choose if room does not reach set temperature    Thermostat displays actual room temperature   Other options   3   2   1  1  2  3  F offset   1 5  C to 1 5  C     No reset  Reset installer options  amp  program schedule to factory  default  only date and time settings are retained     9 69 2693   01    HSIT9NA    HSIT9N3    Installation Guide       Installer system test    During installer setup  press Y  repeatedly until    Test    appears        vied     a  La   co  gt              Test System    number    status                Press AW to Press AW to  select test change status    Press DONE to terminate testing     Shaded areas below apply only to TH8320 TH8321   System test    1    A    Cooling system    Fan system    Heating system    Emergency  heating system    System status     O    OO NaO     O WN    Compressor and fan turn off  Compressor and fan turn on  Second stage compressor turns on    Fan turns off  Fan turns on    Heat and fan turn off   Heat turns on  fan on if Function 0170 is set for heat pump   or if Function 0180 is set to    1        See page 6   Second stage heat turns on   Third stage heat turns on    Heat and fan turn off  Heat and fan turn on    CAUTION  EQUIPMENT DAMAGE HAZARD  Compressor protection is bypassed  during testing  To prevent equipment damage  avoid cycling the compressor quickly     69 2693   01    10    VisionPRO    TH8000 Series    Special functions    
13. ing Temperature Y Cooling 20 30 Vac  SSS Ose Cor te GeO  Y2 Cooling 20 30 Vac  Operating Relative Humidity Aux E Aux  heat 20 30 Vac  e 5  to 90   non condensing  Emergency heat  Physical Dimensions O B Changeover 20 30 Vac  e 4 9 16    H x 6    W x 1 3 8    D L Heat pump reset 20 30 Vac    e 116mm H x 152 mm W x 35 mm D    Need Help     Running Current  0 02 1 0A  100 mA DC  0 02 0 6 A  0 02 1 0A  0 02 0 6 A  0 02 1 0A    0 02 0 6 A  0 02 0 6 A    For assistance with this product please visit http   customer honeywell com  or call Honeywell Customer Care toll free at 1 800 468 1502    Automation and Control Solutions  Honeywell International Inc    1985 Douglas Drive North   Golden Valley  MN 55422  http   customer honeywell com    Honeywell       U S  Registered Trademark       2012 Honeywell International Inc   69 2693   01 M S  01 12   Printed in U S A     
14. or sensor required     Recommended for most compressors   Other options  1  2  4  5 or 6 CPH     Recommended for most compressors   Other options  1  2  4  5 or 6 CPH     Continued on next page    69 2693   01    HSIT9N4    HSITON3    Installation Guide       Installer setup  Setup functions Settings  amp  Options  factory default in bold     Shaded areas below apply only to TH8320 TH8321     0240    0250    0260    0280    0300    0310    0320    0330    0340    0350    0360    0380    69 2693   01    First stage heat  cycle rate  CPH   cycles per hour     Second stage heat  cycle rate  CPH     Third stage heat  cycle rate  CPH     Backlight    Manual Auto  changeover    Auto changeover  deadband    Temperature  display    Daylight savings    Remote sensor    Heat pump  compressor lockout    Heat pump  auxiliary lockout    Dehumidification  control    own a ouv  a     o awn o         Gas or oil furnaces of less than 90  efficiency  Steam or gravity systems   Hot water systems  amp  furnaces of 90   efficiency  Electric furnaces    Other options  2  4  6  7  8  10  11  12 CPH     Gas or oil furnaces of less than 90  efficiency  Steam or gravity systems   Hot water systems  amp  furnaces of 90   efficiency  Electric furnaces    Other options  2  4  6  7  8  10  11  12 CPH     Electric auxiliary heat or electric furnaces  Steam or gravity systems   Hot water systems  amp  furnaces of 90   efficiency  Gas or oil furnaces of less than 90  efficiency   Other options  2  4  6  7  8
    
Download Pdf Manuals
 
 
    
Related Search
    
Related Contents
Mode d`emploi V2.1  Samsung WB500 User Manual  4.9 Laserresonator  Finnish WEST SYSTEM User Manual February 2011.indd  outil de compensation    Aquatic AI36AIR6642HS User's Manual  JY997D29101C USER`S MANUAL  manual de instruções câmera color cmos com  Installation résidentielle ou commerciale/ industrielle    Copyright © All rights reserved. 