1. Residential Flammable Gas Leakage Detector RFR200 Operation Instructions Thank you for choosing Honeywell gas leakage alarm system Please carefully read through the instructions before using this product and perform according to the relevant procedures as provided herein to avoid any damage to this machine or any other incidents incurred by your inappropriate operation The user shall assume any liability arising from or in connection with his or her failure to comply with the instructions in this manual and part installation repair or replacement by unauthorized person For the product its color and style please refer to the actual product as standard Please keep this manual in a safe place for future reference If you should have any doubt or dissatisfaction with our product or service including product technology quality installation and maintenance please contact us immediately so that we can deal with your suggestions in a proper way e Product profile As the gas detection expert Honeywell Analytics brings together nearly 200 collective years of expertise in design manufacture and technology As the leader in gas detection and alarm equipment industry in the world we apply high precision detection standards to domestic gas leakage alarm systems By integration of powerful catalytic flammable sensing technology and advanced electronic technology Honeywell is dedicated to providing multiple protections for both our customers a
2. ation point on the wall Fixing the adapter by screw which is offered Must use the machine screw to the outlet box Must use the tapping screw to the wood wall While installation ensure the wire is routed out through the reserved hole before installation AC wire have to go through the adapter hole Please check the direction of adapter and check the arrow and UP mark Fix the host onto the adapter for mounting with screws a i Ss tS sh Flush mounting in case flush mounting is selected the adapter for mounting is not necessarily used You need to dis connect the AC power wire and remote sensor wire from main Assy and take off the adapter first Remote sensor connector cable ii i a ae Cut off the strip on the left edge of the host with a knife and fixed the machine body into the groove previously excavated on the wall with screws detailed dimensions of the groove width 134mm 136mm height 92mm 93mm If relay is used for signal output then remove the wire trunking and fix it with screws again after connecting the signal line to the corresponding connecting terminal COM Alarm NO Normal open NB BIBAE TST TSE VL __ tS AQ OA som f ee 4 T 7 7 Dp To remove the panel push inward the locking tab and then pull out the panel towards the opposite side F Tet Q i Procedures for remote sensor installation Fix the sensor onto t
3. h 8 times When gas level is less then alarm point return to normal operation If required the audible alarm can be silenced for 5 minutes by pushing Red LED flash 4 times the button marked Test The red N each time Y Same as alarm condition e Service life and warranty period 1 The optimal service life is five years since the purchase please keep your invoice 2 The warranty period for free is one year since the purchase 3 User must read through this instruction manual carefully and operate correctly and Honeywell will repair or replace for free in case the machine does not work due to any quality issue at the manufacturer s side e Operation Standard GB15322 2 2003 e Detection Gas LNG e Installation instruction The detector should be installed in the room with gas consumed equipment and the alarm shall have a horizontal distance of 3m or less from the gas consumed equipment In case natural gas is used the detector may be installed at the height with a 30m distance or less from the ceiling _ 30cm or less a El 3m or less PE E nr 1 2m 1 6m Detecting natural gas a r Check that each part or component is in good condition before installation and get prepared the screws and other attachments we ve provided in the toolkit e Part description Control panel Front cover assy Remote sensor Screw e Procedures for control panel installation Find an appropriate install
4. he ceiling with screws e Incorrect mounting position 1 Places where exhaust steam and oil smoke from gas appliances may directly influence 2 Places near to the air inlet exhaust fan door and window where favorable ventilation is ensured 3 Places which are fenced off by the window curtain vertical curtain cabinet door ceiling and cross beam etc 4 Places with high temperature and moisture like cooking room and boiler room etc 5 Places where power supply of the alarm may possibly be switched off 6 Places outdoor or where the temperature is lower than 10 C or higher than 55 C e Precautions on using 1 Do not switch off the power supply of the alarm otherwise the alarm may not work when gas leakage occurs 2 Do not touch any part of the power supply with wet hand s as this could cause risk of electric shock 3 Do not remove or retrofit the alarm 4 Do not use volatile matters in the vicinity of the alarm like hair spray pesticide paint adhesive agent and alcohol so as to avoid false alarm an eliminate any influence on the service life of the sensitive elements 5 Do not eject high concentration gas into the access opening to avoid performance of the sensor 6 Frequently check the power LED green is always on 7 Press down the self test button of the detector once every 6 months to check it is in normal standby state 8 In case a fault happens in the alarm please contact our company or the
5. local representative office immediately 9 Never connect the power supply to any signal output terminal 10 Prevent the product from falling down from a high level during installation and operation otherwise the performance of the product may be impaired 11 Never attempt to replace the remote probe or change the length of its wire by any unauthorized person 12 Never clean the alarm with a cleaning agent 13 Please keep the alarm away from silicon contained material e Our company will not assume any responsibility for product damage or loss of function caused by the following reasons 1 Consumer s disassembly or intentional damage 2 Force majored like fire earthquake lightening abnormal voltage etc 3 Wrong installation position or failure to switch on power supply of the detector 4 Expiration of the lifetime 5 Falling down impact and other faults and damages incurred by the consumer 6 Other contamination damages faults or damages not caused by the manufacturer Honeywell Trading Shanghai Ltd 430 Li Bing Road Zhangjiang Hi Tech Park Shanghai China H_RFI Manual_09_V1_AP
6. nd their properties e Function and indication chart LED Relay Sage When no gas is present the green YININ En LED On demand test result by press the button Red LED and Yellow LED will y y y En En be blink in order After then return to normal mode Operation Description Timing Interval Always G LED on if power is normal 8 times beep with rea LED flash 4 times and then yellow LED flash 4 times Y alarm will continue to flash for 5 minutes l tee If gas is still present after 5 minutes hush period the audible alarm will sound Oos z lt z lt z E End of life time 5 years yny oo a 3 long chirps min Cell health trouble No cell yo 1 long chirps min EEPROM CRC fail Program N IN Y De De code fail Y Continues beep Alarm relay shall be teseted often 5 seconds of button when normal conduction Power LED green Alarm LES red Fault yellow 1 Power LED green indicates the power system is in normal operation 2 Alarm LED red indicates the concentration of combustible gas leakage reaches the set value 3 Fault LED yellow indicates the alarm is in fault condition On demand test result by press the p button After then return to normal Y N Y N Same as default condition mode When detects gas it will give the alarm signal continuously The red LED and sounder will annunciate Y Y N En En Y e umes peep wiih red LED flas
Download Pdf Manuals
Related Search
Related Contents
PT201 - セイコークロック 21" Electric Lawn Mower Viewsonic 32" Widescreen HD LCD TV 32" HD-Ready Silver 取扱説明書 - SHIMANO Características Instalação Recomendações Importantes Lightolier LP-9 User's Manual DIVAtech MICRO LN F 32 D BIOTOP Mechanical Regulation Descargar USER GUIDE - Hypertech Security Copyright © All rights reserved.