Home
Honeywell Thermostat RTH7000 User's Manual
Contents
1. 6 Wire connections eere 9 Battery installation Thermostat mounting ss Time date 15 System setup How to enter system setup 16 How to change settings 17 System settings 18 24 Appendices Customer assistance In case of difficulty 1 year limited warranty 69 2104ES 01 Installation Guide Installation is easy even if you ve never done it before Your new thermostat has been designed for fast easy installation Install in three simple steps e Label wires and remove your old thermostat See pages 4 5 e Install and wire your new thermostat see pages 6 14 e Set your new thermostat to match your heating cooling system see pages 15 24 Installation tips e Have everything you need ready to go before you begin see page 3 e Do not use wire color as a guide Use wire labels instead see page 7 If you have installation questions call 1 866 228 8942 TURN OFF POWER at heating cooling system or fuse circuit breaker panel before you A begin installation 69 2104ES 01 2 RTH7400 RTH7500 Pre installation checklist Make sure this package includes Required tools amp supplies e No 2 Phillips screwdriver e Small pocket screwdriver Drill e Drill bit 3 16
2. 1 Sistema vapor gas petr leo o sistema gravedad 21 69 2104ES 01 Guia de Instalaci n Configuraci n del instalador Funci n Ajustes opciones 0300 Cambio Oprima A V para seleccionar el cambio manual o autom tico manual O El cambio manual Heat Cool Off o auto 1 El cambio autom tico Heat Cool Auto Off Enciende autom tica RTH7500 mente la calefacci n o refrigeraci n basado en la temperatura inte rior Nota El sistema mantiene la diferencia m nima 3 F entre el calor y los ajustes frescos solamente PRECAUCI N Para evitar da o posible del compresor fije a la opci n 0 si la A temperatura exterior cae debajo de 50 F 10 C 0320 Formatde Oprima A V para seleccionar el formato de la temperatura la tem 0 Fahrenheit p rature o 4 Celsius F C 69 2104ES 01 22 RTH7400 RTH7500 Configuraci n del instalador Funci n Ajustes opciones 0330 0500 Ahorro Oprima A V para seleccionar una opci n diurno 0 horario de ahorro de energ a diurno est desactivado 1 Cambio autom tico a horario de ahorro de energ a diurno 2006 y para reas que no usan el nuevo calendario 2007 DST 2 Cambio autom tico a horario de ahorro de energ a diurno 2007 y posterior para reas que usan el nuevo calendario 2007 DST Recorda Oprima A Y para fijar el intervalo deseado del recordatorio torio de 0 Apagado cambio del 1 Tiempo de funcionamiento de 10 d as alre
3. Month Year Day D 19 Go Back Next Done CN 1 Press A or Y to set month then press NEXT Press A or Y to set day then press NEXT Press A or Y to set year then press DONE Press A or to set time then press DONE to save and exit TIP Don t forget to restore electrical power at the heating cooling system or at the fuse circuit breaker panel 69 2104ES 01 Installation Guide Entering system setup Step 1 System Schedule Clock 8 More Press and release the left button Ld M28068 Step 2 System Fan Done Press and hold the center button until the screen changes approximately 5 seconds M28069 69 2104ES 01 16 RTH7400 RTH7500 Change settings See pages 18 24 to change Function Settings Function Setting e 2 y Y Press A Y to change setting Press NEXT to advance to next function Go Back Done DONE to save amp exit NOTE Because of choices you make while programming some functions in the following pages may not appear 17 69 2104ES 01 Installation Guide Setup functions Settings amp Options 0120 0130 0140 0150 Year Setting Press A to change the first two digits of the year first two digits 20 Year 20xx 21 z Year 21xx Year Setting Press A V to change the last two digits of the year ca two 01 9
4. Heat Pump 1 Match each labeled wire with same letter on new thermostat 2 Use a screwdriver to loosen screws insert wires into hole then tighten screws 3 If E and Aux do not each have a wire connected use a small piece of wire to connect them to each other 4 Push any excess wire back into the wall opening Labels don t match If labels do not match letters on thermostat see page 12 69 2104ES 01 HEAT PUMP SCREW INSERT WIRES THEN TIGHTEN SCREWS LABELED WIRES WIRE HOLE HEAT PUMP 0 S2008SO0 SSD0DS M28104 10 RTH7400 RTH7500 Alternate wiring conventional systems If labels do not match terminals connect wires as shown here see notes below A Remove metal jumper connecting R and Rc only if you must connect both R and Rc wires A If your old thermostat had both R and RH wires remove metal jumper Connect the R wire to the Re terminal and the RH wire to the R terminal If your old thermostat had only 1 C C1 wire connect it to the C terminal If your old thermostat had 2 C or C1 wires wrap each separately with electrical tape and do not connect them 11 w D a or X lt m rae s Qe a c Oe a A v Die M28076 69 2104ES 01 Installation Guide Alternate wiring for heat pumps only Leave metal jumper in place connecting R a
5. for drywall 7 32 for plaster RTH7400 RTH7500 thermostat Operating manual e Hammer wallplate attached to back Wall anchors and Wire labels mounting screws 2 each e Pencil e Electrical tape e Level optional e Two fresh AA alkaline batteries M28071 Note Remove wallplate from the thermostat and see the label on the back of the thermostat for model number 3 69 2104ES 01 Installation Guide Remove your old thermostat 1 Turn off power at heating cooling system or fuse circuit breaker panel 2 Remove cover and thermostat but leave wallplate with wires attached Leave wallplate in place Is there a sealed tube containing mercury If so see inside front cover of this manual for proper disposal instructions Old thermostat M28099 69 2104ES 01 4 RTH7400 RTH7500 Label wires and remove old wallplate Use a screwdriver to disconnect wires one by one As you disconnect each wire wrap it with the label matching the letter on your old thermostat Adhesive labels are supplied in your thermostat package Remove the old wallplate only after all wires are labeled Be careful not to let loose wires fall into the wall opening Wrap supplied labels securely around each wire Do not let wires fall into wall opening IGNORE WIRE COLORS Use only letter designations to identify wire types M28072 5 69 2104ES 01 Installation Guide Remove w
6. to the place from which you pur chased it or ii call Honeywell Customer Care at 1 800 468 1502 Customer Care will make the determina tion whether the product should be returned to the following address Honeywell Return Goods Dock 4 MN10 3860 1885 Douglas Dr N Golden Valley MN 55422 or whether a replacement product can be sent to you This warranty does not cover removal or reinstallation costs This warranty shall not apply if it is shown by Honeywell that the defect or malfunction was caused by damage which occurred while the product was in the possession of a consumer 69 2104ES 01 28 RTH7400 RTH7500 1 year limited warranty Honeywell s sole responsibility shall be to repair or replace the product within the terms stated above HONEYWELL SHALL NOT BE LIABLE FOR ANY LOSS OR DAMAGE OF ANY KIND INCLUDING ANY INCIDENTAL OR CONSEQUENTIAL DAMAGES RESULTING DIRECTLY OR INDIRECTLY FROM ANY BREACH OF ANY WARRANTY EXPRESS OR IMPLIED OR ANY OTHER FAILURE OF THIS PRODUCT Some states do not allow the exclusion or limitation of incidental or consequential damages so this limitation may not apply to you THIS WARRANTY IS THE ONLY EXPRESS WARRANTY HONEYWELL MAKES ON THIS PRODUCT THE DURATION OF ANY IMPLIED WARRANTIES INCLUDING THE WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE IS HEREBY LIMITED TO THE ONE YEAR DURATION OF THIS WARRANTY Some states do not allow limitations on how long an implied warranty
7. dtsc ca gov hazardouswaste perchlorate en un tubo sellado Comun quese con la autoridad local de disposici n de desechos para AVISO DE MERCURIO No arroje su viejo termostato a la basura si contiene mercurio recibir instrucciones sobre reciclado y eliminaci n correcta Necesita ayuda Para recibir asistencia con este producto visite http DIYthermostats honeywell com o llame gratis al Servicio de Atenci n al Cliente Honeywell al 1 866 228 8942 Lea y guarde estas instrucciones Marca registrada en EE UU Patentes pendientes Copyright O 2007 Honeywell International Inc Todos los derechos reservados RTH7400 RTH7500 Indice de materias Para comenzar Ajuste del sistema Consejos de instalaci n 2 Como entrar al programa de Lista de comprobaci n previa configuraci n del sistema 16 instalaci n eene 3 Como cambiar la configuracion Ajustes del sistema Remoci n del viejo termostato Remueva el viejo termostato Ap ndices Identifique y rotule los cables En caso de dificultades 25 Asistencia al cliente 27 Garant a limitada de 1 a o 28 Instalaci n del nuevo termostato Instalaci n de la placa de montaje 6 Conexi n de los cables Instalaci n de bater a Montaje del termos
8. en las perforaciones y luego wa apriete de nuevo los tornillos G Y2 3 Coloque todo el excedente de Y cable en el interior de la abertura w en la pared Si las etiquetas no coinciden Si las etiquetas no coinciden con las letras del termostato Ver pagina 11 M28070 Extraiga el puente met lico si Si tiene un sistema de Bomba de Calefacci n tiene ambos cables R y Ro Ver la pagina 10 9 69 2104ES 01 Guia de Instalaci n Cableado Bomba de Calefacci n 1 Conecte cada cable con la SCREW terminal que le corresponde seg n INSERT WIRES su letra de identificaci n en el THEN TIGHTEN SCREWS termostato nuevo LABELED WIRES 2 Use un desarmador para aflojar HEAT PUMP los tornillos introduzca los cables en las perforaciones y luego apriete los tornillos Glo 3 Si E y Aux no estan cableados por separado use una pieza peque a de cable para conectarlos entre si 4 Coloque todo el excedente de cable en el interior de la abertura en la pared M28104 Si las etiquetas no coinciden Si las etiquetas no coinciden con las letras del termostato Ver pagina 12 69 2104ES 01 10 WIRE HOLE HEAT PUMP RC q OON peo SSD0DS RTH7400 RTH7500 Cableado alterno sistemas convencionales Si los r tulos no coinciden con las letras del termostato consulte el gr fico que figura a la dere
9. lasts so the above limita tion may not apply to you This warranty gives you specific legal rights and you may have other rights which vary from state to state If you have any questions concerning this warranty please write Honeywell Customer Relations 1985 Douglas Dr Golden Valley MN 55422 or call 1 800 468 1502 In Canada write Retail Products ON15 02H Honeywell Limited Honeywell Limit e 35 Dynamic Drive Toronto Ontario M1V4zZ9 29 69 2104ES 01 Automation and Control Systems Honeywell International Inc Honeywell Limited Honeywell Limit e 1985 Douglas Drive North 35 Dynamic Drive Golden Valley MN 55422 Toronto Ontario M1V 4Z9 http DIYthermostats honeywell com Printed in U S A on recycled paper containing at least 1096 post consumer paper fibers neywe U S Registered Trademark 2007 Honeywell International Inc 69 2104ES 01 M S 09 07 Honeywell A Gu a de Y Instalaci n ENERGY STAR 69 2104ES 01 Serie RTH7000 Termostato programable Este termostato proporciona control de sistemas de calefacci n y refriger aci n de 24 VCA o sistemas de calefacci n de 750 mV Ce manuel est pour les mod les RTH7400 et RTH7500 Enlevez le thermostat du wallplate et l inversez pour trouver le num ro de type Este termostato tiene una bater a de litio que puede contener perclorato Perclorato puede ser necesario manipularlo con m todos especiales Visite www
10. 01 Guia de Instalaci n Retire la placa de montaje e instale la tarjeta de referencia Inserte el dedo en el orificio para cables y tire para retirar la placa de montaje del nuevo termostato Placa de montaje M28073 69 2104ES 01 6 RTH7400 RTH7500 Marque la posici n de la placa de montaje 1 Tire de los cables 2 Nivele la placa de montaje 3 Marque las posiciones a trav s de la si lo desea coloque el nivel de ambos orificios placa de montaje horizontal entre las leng etas M28074 7 69 2104ES 01 Guia de Instalaci n Coloque placa de montaje 1 Taladre orificios en las posiciones marcadas Orificios de 3 16 para mamposter a en seco Orificios de 7 32 para yeso 2 Con un martillo golpee suavemente los soportes de um pared e introd zcalos en los orificios hasta que queden al ras de la pared 3 Coloque la placa de montaje sobre los soportes e inserte los tornillos Revise el nivel si lo desea y luego ajuste los tornillos 69 2104ES 01 8 RTH7400 RTH7500 Cableado Calefacci n y Refrigeraci n convencional 1 Conecte cada cable con la SCREW terminal que le corresponde_ INSERT WIRES seg n su letra de identificaci n THEN TIGHTEN SCREWS en el termostato nuevo CONVENTIONAL LABELED WIRES CONVENTIONAL 2 Use un desarmador para aflojar WIRE HOLE los tornillos introduzca los cables
11. 15 02H Honeywell Limited Honeywell Limit e 35 Dynamic Drive Toronto Ontario M1V4Z9 29 69 2104ES 01 Sistemas para automatizaci n y control Honeywell International Inc Honeywell Limited Honeywell Limit e 1985 Douglas Drive North 35 Dynamic Drive Golden Valley MN 55422 Toronto Ontario M1V 4Z9 http DIYthermostats honeywell com Impreso en los EE UU en papel reciclado que contiene por lo menos Ho ne el un 10 de fibras de papel reciclable yw Marca registrada de los EE UU 2007 Honeywell International Inc 69 2104ES 01 M S 09 07
12. 5 69 2104ES 01 Guia de Instalaci n Ingresando la configuraci n del sistema Paso 1 System Schedule Clock amp More Presione y suelte el bot n izquierdo Paso 2 System Fan Done M28069 Presione y mantenga presionado el bot n del centro hasta que la pantalla cambie 5 segundos aproximadamente 69 2104ES 01 16 RTH7400 RTH7500 Cambios en la configuracion Ver paginas 18 24 para cambiar la configuraci n del programa Funci n Ajuste Es Go Back Nox Es Oprima NEXT para seleccionar la funci n amp aie Y para cambiar los ajustes Oprima DONE para salir y guardar los ajustes NOTA Debido a opciones que usted hace mientras que programa algunas funciones en las p ginas siguientes no puede aparecer 17 69 2104ES 01 Guia de Instalaci n Configuraci n del instalador Funci n Ajustes opciones 0120 Ajuste de Oprima A V para cambiar los primeros dos d gitos del a o a o prim 20 A o 20xx eros dos digitos 21 A o 21xx 0130 Ajuste Oprima A V para cambiar los ltimos dos d gitos del a o de a o segundos 017 99 ej 2001 2099 dos d gi tos 0140 Ajuste de Oprima A V para cambiar el mes actual NOTA Si ya asigno la mes 01 12 c d ier D b hora y fecha como se 12 c a d Janvier D cembre muestra en la pagina 0150 Ajuste de Oprima A V para cambiar la fecha
13. 9 i e 2001 2099 Month Setting Press A V to change the current month 01 12 i e January December Date Setting Press A V to change the current date 9r NOTE If you set the time and date as shown on page 15 press A to function 0170 and go to page 19 69 2104ES 01 18 RTH7400 RTH7500 Setup functions Settings amp Options 0170 Select System Type Press A V to select your system type 1 2 3 4 Heat cool Gas oil or electric heating with central air conditioning Heat pump Heat pump without backup or auxiliary heat Heat only Gas oil or electric heat without central air conditioning Heat only with fan Gas oil or electric heat without central air con ditioning Hot water heat only no fan Gas oil or hot water heat without central air conditioning Cool only Central air conditioning only Heat pump Heat pump with backup or auxiliary heating Heat Cool Multiple stages 2 heat stages wires on W and W2 2 cooling stages wires on Y and Y2 Heat Cool Multiple stages 2 heat stages wires on W and W2 1 cooling stage wire on Y Heat Cool Multiple stages 1 heat stage wire on W 2 cooling stages wires on Y and Y2 19 69 2104ES 01 Installation Guide Setup functions Settings amp Options 0180 Heating Fan Press A V to select your heating system amp fan control Control 0 Gas or oil heat Use this setting if you have a gas or oil heating system system co
14. Honeywell Installation Guide EL ENERGY STAR RTH7000 Series Programmable Thermostat 69 2104ES 01 This thermostat provides control of 24 VAC heating and cooling systems or 750mV heating systems This manual covers RTH7400 and RTH7500 models Pull thermostat from wallplate and turn over to find model number This thermostat contains a Lithium battery which may contain Perchlorate material Perchlorate Material special handling may apply See www dtsc ca gov hazardouswaste perchlorate mercury in a sealed tube Contact your local waste management authority for MERCURY NOTICE Do not place your old thermostat in the trash if it contains instructions regarding recycling and proper disposal Need Help For assistance with this product please visit http DIYthermostats honeywell com or call Honeywell Customer Care toll free at 1 866 228 8942 Read and save these instructions U S Registered Trademark Patents pending Copyright 2007 Honeywell International Inc All rights reserved RTH7400 RTH7500 Table of contents Getting started Installation tips eerie 2 Pre installation checklist 3 Old thermostat removal Remove old thermostat 4 Identify and label wires 5 New thermostat installation Wallplate mounting
15. actual 15 presione A hasta fecha 01 31 la funci n 0710 y ver pagina 19 69 2104ES 01 18 RTH7400 RTH7500 Configuraci n del instalador Funci n Ajustes opciones 0170 Seleccione Oprima A V para seleccionar su tipo del sistema el tipo del sistema oN 0 ahon Calefacci n a gas petr leo o el ctrica con aire acondicionado central Bombeo de calor Heat pump without backup or auxiliary heat S lo calefacci n gas petr leo o el ctrica sin aire acondicionado central S lo calefacci n gas petr leo o el ctricacon con el ventilador Solamente calefacci n de agua caliente no ventilador Gas petr leo o agua caliente sin aire acondicionado central S lo refrigeraci n Bomba de calefacci n sin refuerzo o calefacci n auxiliar Calefacion Refrigeracion de etapas multiples 2 etapas calefacci n alambres en W y W2 2 etapas refrigeraci n alambres en Y y Y2 Calefacion Refrigeracion de etapas multiples 2 etapas calefacci n alambres en W y W2 1 etapa refrigeraci n alambre en Y Calefacion Refrigeracion de etapas multiples 1 etapas calefacci n alambres en W 2 etapas refrigeraci n alambres en Y y Y2 19 69 2104ES 01 Guia de Instalaci n Configuraci n del instalador Funci n Ajustes opciones 0180 Control del Oprima A V para seleccionar su sistema de calefacci n ventilador 0 Calefacci n a gas petr leo Operaci n del ventilador de los con de calefac trol
16. allplate from new thermostat Grasp top and bottom of wallplate and pull to remove from your new thermostat Wallplate M28073 69 2104ES 01 6 RTH7400 RTH7500 Mark wallplate mounting position 1 Pull wires through 2 Level wallplate if desired 3 Mark positions of wallplate both screw holes M28074 7 69 2104ES 01 Installation Guide Mount wallplate 1 Drill holes at pencil marked locations 3 16 holes for drywall 7 32 holes for plaster 2 Use hammer to tap _ anchors into holes until flush with wall 3 Place wallplate over anchors and insert screws Check level if desired then tighten screws M28075 69 2104ES 01 8 RTH7400 RTH7500 Connect wires Conventional Heating and Cooling 1 Match each labeled wire with SCREW same letter on new thermostat INSERT WIRES THEN TIGHTEN SCREWS 2 Use a screwdriver to LABELED WIRES loosen screws insert wires CONVENTIONAL CONVENTIONAL into hole then tighten screws M G Y WIRE HOLE w2 3 Push any excess wire back into the wall opening Y2 Labels don t match If labels do not match letters on thermostat see page 11 R Have a Heat Pump System M28070 See page 10 Remove metal jumper if you have both R and Re wires 9 69 2104ES 01 Installation Guide Connect wires
17. cha y conecte a los terminales como se muestra aqu ver notas a continuaci n Quite el empalme met lico que conecta R y Re solamente si usted debe conectar los alambres de R y de Rc Si su viejo term stato ten a R y Re los alambres quite el empalme Conecte el alambre de R con el terminal de Rc y el alambre Re con el terminal de R gt gt Si su viejo term stato tenia solamente 1 alambre C o C1 con ctelo con el terminal de C Si su viejo term stato ten a 2 alambres C o C1 envuelva cada uno con la cinta el ctrica y no los conecte gt 11 nep A De ae Die a Y Die mm Q c Oe 2 W2 Ge 69 2104ES 01 Guia de Instalaci n Cableado alterno para bombas de calefacci n solamente gt gt gt PPP Deje el empalme en lugar entre terminales de R y Rc Si su viejo term stato ten a alambres V y VR ahora pare y entre en contacto con un contratista para la ayuda Si su viejo term stato ten a alambres separados de O y de B una el alambre de B al terminal de C Si otro alambre se une al terminal de C ahora pare y entre en contacto con un contratista para la ayuda Si su viejo term stato ten a alambres Y1 W1 y W2 ahora pare y entre en contacto con un contratista para la ayuda Si se utiliza L terminal el alambre terminal de C debe ser conectado entre en contacto con un contratista si no hay alambre de C Si E y los ter
18. dedor de 1 mes filtro dela 2 Tiempo de funcionamiento de 30 d as alrededor de estufa 3 meses Nota Oprima 3 Tiempo de funcionamiento de 60 d as alrededor de RESET para 6 meses cancelar la 4 Tiempo de funcionamiento de 90 dias alrededor de alarma 9 meses 5 Tiempo de funcionamiento de 120 d as alrededor de 1 a o 6 Tiempo de funcionamiento de 365 d as alrededor de 3 a os 23 69 2104ES 01 Guia de Instalaci n Configuraci n del instalador Funci n Ajustes opciones 0530 Smart Oprima A V para seleccionar o para deselect esta caracter stica ver el Response Manual de Uso para m s informaci n Technology 1 Activo O Apagado 0640 Formato Oprima A V para seleccionar el formato del reloj del reloj 12 Reloj 12 hour 3 30 pm 24 Reloj 24 hour 15 30 pm Presione el bot n DONE para guardar cambios y salir de la configuraci n del sistema Felicidades la instalaci n de su termostato ha sido completada 69 2104ES 01 24 RTH7400 RTH7500 En caso de dificultades Si usted tiene dificultades con su termostato pruebe las sugerencias que figuran a continuaci n La mayor a de los problemas se pueden solucionar r pida y f cilmente Pantalla en blanco No se puede cambiar el sistema a refrigeraci n El ventilador no se enciende al requerirse calefacci n El equipo de calefacci n funciona en modo de refrigeraci n Aseg rese de que est n bien instaladas las nueva
19. dos mientras el producto estaba en posesi n de un consumidor La nica responsabilidad de Honeywell ser reparar o reemplazar el producto dentro de los _ plazos establecidos anteriormente HONEYWELL NO RESPONDERA POR LA PERDIDA O DANO 69 2104ES 01 28 RTH7400 RTH7500 Garant a limitada de 1 a o DE NING N TIPO INCLUIDO EL DA O INCIDENTAL O INDIRECTO DERIVADO DIRECTA O INDIRECTAMENTE DEL INCUMPLIMIENTO DE LAS GARANT AS EXPRESAS O IMPLIC TAS O DE OTRAS FALLAS DE ESTE PRODUCTO Algunos estados no permiten la exclusi n o limitaci n del da o incidental o indirecto entonces esta limitaci n puede no resultar aplicable a su caso LA PRESENTE GARANT A ES LA NICA GARANT A EXPRESA QUE HONEYWELL PROPORCIONA RESPECTO DE ESTE PRODUCTO LA DURACI N DE LAS GARANT AS IMPL CITAS INCLUIDAS LAS GARANT AS DE COMERCIABILIDAD Y APTITUD PARA UN OBJETIVO PARTICULAR ESTA LIMITADA A LA DURACI N DE UN ANO DE LA PRESENTE GARANT A Algunos estados no permiten las limitaciones sobre la duraci n del per odo de una garant a impl cita entonces la limitaci n anterior puede no resultar aplicable a su caso Esta garant a le brinda derechos legales espec ficos y usted podr tener otros derechos que var an seg n el estado Si tiene preguntas sobre la presente garant a s rvase escribir a Honeywell Customer Relations 1985 Douglas Dr Golden Valley MN 55422 o llamar al 1 800 468 1502 En Canad escriba a Retail Products ON
20. ears to cancel the alert 23 69 2104ES 01 Installation Guide Setup functions Settings amp Options 0530 Smart Press A V to turn this feature on or off see Operating Manual for Response more information Technology 1 On 0 Off 0640 Clock Format Press A V to set the clock display format 12 12 hour clock i e 3 30 pm 24 24 hour clock i e 15 30 Press DONE to save changes and exit system setup Congratulations your thermostat installation is complete 69 2104ES 01 24 RTH7400 RTH7500 Customer assistance For assistance with this product please visit http DIYthermostats honeywell com or call Honeywell Customer Care toll free at 1 866 228 8942 25 69 2104ES 01 Installation Guide In case of difficulty If you have difficulty with your thermostat please try the following suggestions Most problems can be corrected quickly and easily Display is blank e Make sure fresh AA alkaline batteries are properly installed see page 13 Cannot change e Check Function 0170 System Type to make sure it is set to match system setting your heating and cooling equipment see page 19 to Cool Fan does not e Check Function 0180 Heating Fan Control to make sure it is set to turn on when match your heating equipment see page 20 heat is required Heating system Check Function 0170 System Type to make sure it is set to match is running in your heating and cooling eq
21. es de sistema cion 1 Calefacci n el ctrica El term stato controla la operaci n del ven tilador 0190 V lvulade Oprima A V para seleccionar si su v lvula de cambio est utilizada en la cambio calefacci n o refrigeraci n para O V lvula del cambio que se refrigeraci n Utilice este ajuste si bomba de usted conect un alambre etiquetado O con el terminal de O B ver ale fac pagina 10 cion sola 1 V lvula del cambio que se calefacci n Utilice este ajuste si usted conect un alambre etiquetado B con el terminal de O B ver p gi na 10 O NOTA Presiona el boton NEXT para continuar mente 69 2104ES 01 20 RTH7400 RTH7500 Configuraci n del instalador Funci n Ajustes opciones 0240 0270 Frecuencia Oprima A V para seleccionar su sistema de calefacci n del ciclo 5 Estufa normal a gas o petr leo que tiene una eficiencia menor al de calefac 90 9 Estufa el ctrica sistema de calefacci n el ctrico 3 Sistema de agua caliente o una estufa a gas con una eficiencia mayor al 90 1 Sistema vapor gas o petr leo o sistema gravedad Calefac Oprima A V para seleccionar su sistema de calefacci n ci n dela 9 Estufa el ctrica sistema de calefacci n el ctrico emergen 5 Estufa normal a gas o petr leo que tiene una eficiencia menor al cia para 90 bomba de calefac 3 Sistema de agua caliente o una estufa a gas con una eficiencia ci n sola mayor al 90
22. l sistema de bombeo de calor para asegurarse de que est configurada correctamente para su sistema ver p gina 20 26 RTH7400 RTH7500 Asistencia al cliente Si necesita asistencia visite http DIYthermostats honeywell com o llame al n mero gratuito de atenci n al cliente de Honeywell al 1 866 228 8942 27 69 2104ES 01 Guia de Instalaci n Garant a limitada de 1 a o Honeywell garantiza este producto a excepci n de la bater a por el t rmino de un 1 a o contra cualquier defecto de fabricaci n o de los materiales a partir de la fecha de compra por parte del consumidor Si en cualquier momento durante el per odo de garant a se verifica que el producto tiene un defecto o que funciona mal Honeywell lo reparar o reemplazar a elecci n de Honeywell Si el producto tiene defectos i devu lvalo con la factura de venta u otra prueba de compra fechada al lugar donde lo compr o ii comun quese con el Centro de atenci n al cliente de Honeywell al 1 800 468 1502 Atenci n al cliente decidir si se debe devolver el producto a la siguiente direcci n Devoluci n de mercader as de Honeywell Dock 4 MN10 3860 1885 Douglas Dr N Golden Valley MN 55422 o si se le puede enviar un producto en reemplazo Esta garant a no cubre los costos de extracci n o reinstalaci n Esta garant a no se aplicar si Honeywell demuestra que el defecto o mal funcionamiento estaba causado por da os ocurri
23. minales Aux cada uno no tienen un alambre conectado utilice un pedazo pequefio de alambre para conectarlos el uno al otro 69 2104ES 01 12 RTH7400 RTH7500 Instale las baterias Instale dos baterias alcalinas AA en la parte de atras del termostato M28101 Parte de atras del termostato 13 69 2104ES 01 Guia de Instalaci n Retire la leng eta y arme el termostato Retire la leng eta URING E INSTALLATION remova M28102 Alinee las espigas de la parte de atr s del termostato con las ranuras de la placa de montaje luego presione suavemente hasta que el termostato calce en su lugar M28103 NOTA Si interfieren los alambres cuando usted intenta montar el term stato empuje exceso del alambre nuevamente dentro de la abertura de la pared 69 2104ES 01 14 RTH7400 RTH7500 Ajuste de fecha y hora El mes El a o La fecha 1 Oprima A o Y para ajustar el mes despu s oprima NEXT 2 Oprima A o Y para ajustar E la fecha despu s oprima NEXT 15 A 3 Oprima A o Y para ajustar el a o despu s oprima DONE 4 Oprima A o Y para ajustar la hora despu s oprima DONE para salir y guardar los ajustes Go Back Next Done NOTA se olvide de restaurar corriente el ctrica en el sistema de calefacci n refrigeraci n o en el panel de fusibles disyuntor 1
24. mp Rc terminals If your old thermostat had both V and VR wires stop now and contact a qualified contractor for help If your old thermostat had separate O and B wires attach the B wire to the C terminal If A O B another wire is attached to the C terminal Y stop now and contact a qualified contractor for help If your old thermostat had Y1 W1 and W2 wires stop now and contact a qualified contractor for help If L terminal is used C terminal wire must be connected contact a contractor if there is no C wire If E and Aux terminals do not each have a wire connected use a small piece of wire to connect them to each other gt gt gt bbb 69 2104ES 01 12 Die a De Tam Ole a Cle m Die m Ole nmm Qe mem usw M28077 RTH7400 RTH7500 Install batteries Install 2 fresh AA alkaline batteries in back of thermostat M28101 Back of thermostat 13 69 2104ES 01 Installation Guide Remove tab and mount thermostat Remove tab URING E INSTALLATION remova M28102 Align pins on back of thermostat with slots in wallplate then push gently until thermostat snaps into place M28103 TIP If wires interfere when you try to mount the thermostat push excess wire back into the wall opening 69 2104ES 01 14 RTH7400 RTH7500 Set time date and restore electrical power
25. ntrols fan operation 1 Electric heat Use this setting if you have an electric heating system thermostat controls fan operation 0190 Heat Pump Press A V to select whether your changeover valve is used in heating or Changeover cooling Valve for heat 0 Cooling changeover valve Use this setting if you connected a wire pumps only labeled O to the O B terminal see page 10 1 Heating changeover valve Use this setting if you connected a wire labeled B to the O B terminal see page 10 qp NOTE Press NEXT button to continue 69 2104ES 01 20 RTH7400 RTH7500 Setup functions Settings amp Options 0240 Heating Cycle Rate 0270 Emergency Heat Cycle Rate heat pumps only Press A V to select your heating system 5 9 3 Gas oil furnace Standard gas oil furnace less than 90 efficiency Electric furnace Electric heating systems Hot water or high efficiency furnace Hot water system or gas furnace more than 90 efficiency Gas oil steam or gravity system Steam or gravity heat systems Press A V to select your heating system 9 5 3 1 Electric furnace Electric heating systems Gas or oil furnace Standard gas oil furnace less than 90 efficiency Hot water or high efficiency furnace Hot water system or gas furnace more than 90 efficiency Gas oil steam or gravity system Steam or gravity heat systems 21 69 2104ES 01 Installation Guide Set
26. os cables e 2 bater as alcalinas AA plane ae inated posterior montaje del termostato vea la etiqueta en el reverso 3 69 2104ES 01 o Nota Para el n mero de modelo extraiga la placa de Guia de Instalaci n Remueva su viejo termostato 1 Desconecte la alimentaci n en el sistema de calefacci n refrigeraci n o en el panel de fusibles disyuntor 2 Retire la cubierta y el termostato pero deje los cables unidos a la placa de montaje Deje la placa de montaje en su lugar Hay un tubo sellado que contiene M mercurio Si es as consulte en la cubierta de este manual las instrucciones para su desecho apropiado Termostato viejo M28099 69 2104ES 01 4 RTH7400 RTH7500 Rotule los cables y retire la vieja placa de montaje Use un destornillador para desconectar los cables uno a uno A medida que desco necte cada cable p guele alrededor el r tulo con la misma letra que figura en su viejo termostato En el paquete de su termostato se incluyen r tulos autoadhesivos Retire la vieja placa de montaje s lo despu s de haber rotulado todos los cables Tenga cuidado de no dejar que los cables sueltos caigan en el hueco de la pared Envuelva firmemente los r tulos provistos alrededor de cada cable No permita que los cables caigan en el hueco de la pared IGNORE LOS COLORES DE LOS CABLES Use s lo letras para identificar los tipos de cable M28072 5 69 2104ES
27. s bater as alcalinas AA ver p gina 13 Verifique la Funci n 170 Tipo de sistema para asegurarse de que est ajustado para su sistema de refrigeraci n y calefacci n ver p gina 19 Verifique la Funci n 180 Control de ventilador de calefacci n para asegurarse que est ajustado para su equipo de calefacci n ver p gina 20 Verifique la Funci n 170 Tipo de sistema para asegurarse de que est ajustado para su sistema de refrigeraci n y calefacci n ver p gina 19 25 69 2104ES 01 Guia de Instalaci n En caso de dificultades No responde el sistema de calefacci n o refrigeraci n Wait aparece en la pantalla El bombeo de calor emite aire fr o en modo calefacci n o aire caliente en modo refrigeraci n 69 2104ES 01 Oprima SYSTEM para fijar el sistema en Heat Aseg rese de que la temperatura sea superior a la temperatura interior Oprima SYSTEM para fijar el sistema en Cool Aseg rese de que la temperatura sea inferior a la temperatura interior Verifique el disyuntor y reinicie si es necesario Aseg rese de que est encendido el interruptor del sistema de calefacci n y refrigeraci n Aseg rese de que est bien cerrada la puerta de la estufa Espere 5 minutos la respuesta del sistema La funci n de protecci n del compresor est activada Espere 5 minutos el reinicio seguro del sistema sin da ar el compresor Verifique la Funci n 190 V lvula de cambio de
28. tato Cambie la hora y la fecha 15 1 69 2104ES 01 Guia de Instalaci n La instalaci n es f cil Su nuevo termostato fue dise ado para que su instalaci n sea f cil y r pida Instale en tres pasos sencillos e Rotule los cabes y retire el termostato viejo ver p ginas 4 5 e Instale y conecte los cables de su nuevo termostato ver p ginas 6 14 e Ajuste su nuevo termostato para que concuerde con su sistema de calefacci n refrigeraci n ver p ginas 15 24 Consejos de instalaci n e Tenga listo todo lo que necesita antes de comenzar ver p gina 3 e No use el color de los cables como guia En su lugar use r tulos en los cables ver p gina 7 Si tiene dudas de instalaci n llamar al 1 866 228 8942 A DESCONECTE LA ALIMENTACI N en el sistema de calefacci n refrigeraci n o en el panel de fusibles disyuntor antes de usted comience 69 2104ES 01 2 RTH7400 RTH7500 Lista de comprobaci n previa a la instalaci n Aseg rese de que el paquete contenga los siguientes elementos Herramientas y materiales necesarios e Destornillador Phillips No 2 e Destornillador peque o de bolsillo e Taladro Mecha de taladro 3 16 para Soportes de pared y tornillos Manual de uso mamposter a en seco 7 32 para de montaje 2 cada uno yeso Martillo gt e L piz Cinta el ctrica depo Nivel optativo Termostato 0 Rotulos l
29. uipment see page 19 cool mode 69 2104ES 01 26 RTH7400 RTH7500 In case of difficulty Heating or cooling system does not respond Wait appears on the screen Heat pump issues cool air in heat mode or warm air in cool mode Press SYSTEM to set system to Heat Make sure the temperature is set higher than the Inside temperature Press SYSTEM to set system to Cool Make sure the temperature is set lower than the Inside temperature Check circuit breaker and reset if necessary Make sure power switch at heating amp cooling system is on Make sure furnace door is closed securely Wait 5 minutes for the system to respond Compressor protection feature is engaged Wait 5 minutes for the system to restart safely without damage to the compressor Check Function 0190 Heat Pump Changeover Valve to make sure it is properly configured for your system see page 20 27 69 2104ES 01 Installation Guide 1 year limited warranty Honeywell warrants this product excluding battery to be free from defects in the workmanship or materials under normal use and service for a period of one 1 year from the date of pur chase by the consumer If at any time during the warranty period the product is determined to be defective or malfunctions Honeywell shall repair or replace it at Honeywell s option If the product is defective i return it with a bill of sale or other dated proof of purchase
30. up functions Settings amp Options 0300 Manual Auto Press A V to select manual or automatic changeover Changeover 0 Manual changeover Heat Cool Off RTH7500 only 1 Automatic changeover Heat Cool Auto Off Automatically turns on Heat or Cool based on room temperature Note System maintains minimum 3 F difference between heat and cool settings CAUTION To avoid possible compressor damage set to option O if the outside A temperature drops below 50 F 10 C 0320 Temperature Press A V to set the temperature display format Format F C O Fahrenheit 1 Celsius 69 2104ES 01 22 RTH7400 RTH7500 Setup functions Settings amp Options 0330 0500 Daylight Sav Press A V to select an option ings Time 0 Off No adjustment for daylight savings time On Off 1 Auto change to daylight savings time through 2006 and for areas that do not use the new 2007 DST calendar 2 Auto change to daylight savings time 2007 and beyond for areas that use the new 2007 DST calendar Furnace Filter Press A V to set the desired reminder interval Change Reminder ONA ON 0 Off no reminder to change furnace filter z Reminder after 10 day run time about 1 month Not RET Reminder after 30 day run time about 3 months Reminder after 60 day run time about 6 months Reminder after 90 day run time about 9 months Reminder after 120 day run time about 1 year Reminder after 365 day run time about 3 y
Download Pdf Manuals
Related Search
Related Contents
Dale Tiffany TH90217 Installation Guide YDC-15N La Crosse Technology WS-6118AL-IT User's Manual VIAZYM CLARIF ONE Notice - AstralPool ShelterLogic 90490 Instructions / Assembly KALED32XXXYC 32" LED TV (HD) User Manual www.jardins-animes.com Edition du 12 / 01 / 2011 Spark MY2014 Copyright © All rights reserved.