1. 1 Specifications Ordering Information 2 Installation Operation Checkout saec Replacement Parts Exploded 17 5 68 0240EF F300 ELECTRONIC AIR CLEANER SPECIFICATIONS IMPORTANT The specifications given in this publication do not include normal manufacturing tolerances Therefore this unit may not exactly match the listed specifica tions This product is tested and calibrated under closely controlled conditions and some minor differ ences in performance can be expected if those con ditions are changed Model F300E Electronic Air Cleaner Includes cabinet access door solid state power supply two electronic cells two metal mesh prefilters and two media postfilters F300A B Electronic Air Cleaner Includes cabinet access door solid state power supply two electronic cells and two metal mesh prefilters Electrical Ratings Voltage and Frequency Models available for 120V 60 Hz 240V 60Hz 120V models can be converted in the field to 240V 60 Hz or 220 240V 50 Hz with the 203365A Conversion Kit Power Consumption One cell models 22 W maximum Two cell models 36 W maximum Current Draw See Table 1 lonizer Voltage 8150 Vdc Collector Voltage 4075 Vdc ORDERING INFORMATION Table 1 Current Draw Size Max Current
2. 60 40 140 F Installation S installe dans la gaine de reprise d air d un syst me de chauffage de refroidissement et de ventilation a air puls Devrait tre install en amont d un humidificateur atomiseur Voir la section Planification de l installation Poids Voir le Tableau 3 Encombrement Voir la Fig 2 R pertori s U L n de dossier E30954 Accessoires 203365A Ensemble de conversion du bloc d alimentation de 120 V 60 Hz en un bloc de 240 V 60 Hz ou de 220 240 V 50 Hz W8600F Moniteur W8600A Indicateur AIRWATCH Pi ces de rechange Voir l illustration des pi ces de rechange vue explos e et le tableau qui l accompagne 68 0240EF 5 FILTRE A AIR ELECTRONIQUE F300 Tableau 3 Poids l exp dition et l installation DIM D VOIR TABLEAU ____ gt Low 0 ro ro m ro ww ro Fig 2 Encombrement en mm po Installation du filtre air lectronique 68 0240EF 5 MF19776 Poids 406 x 508 mm 406 x 635 mm 508 x 318 508 x 635 mm 508 x 508 mm 16 x 20 po 16 x 25 po 20 x 12 1 2 20 x 25 po 20 x 20 po kg Ib kg Ib kg Ib kg Ib kg Ib Cellule lectronique chacune 2 25 5 2 7 6 3 4 7 1 2 2 8 63 16 3 4 7 l exp dition 13 6 30 15 0 33 11 3 25 15 0 33 17 2 38 Install cellules comprises 11 6
3. Table des mati res Caract ristiques Fiche Technique Planification de l installation Installation Fonctionnement V rification Maintenance Pi ces de rechange vue explos e 68 0240EF 5 FILTRE AIR ELECTRONIQUE F300 FICHE TECHNIQUE IMPORTANT Les caract ristiques techniques indiqu es dans la pr sente publication ne comprennent pas les tol rances normales de fabrication Par cons quent il se peut que l appareil ne corresponde pas exactement aux caract ristiques indiqu es De m me le produit a t mis l essai et talonn dans des conditions enti rement contr l es et on peut s attendre de l g res diff rences de fonctionnement si ces conditions sont modifi es Mod le F300E Filtre air lectronique avec bo tier porte d acc s bloc d alimentation semi conducteurs deux cellules lectroniques deux pr filtres en mailles m talliques et deux post filtres fibres F300A B Filtre air lectronique avec bo tier porte d acc s bloc d alimentation semi conducteurs deux cellules lectroniques et deux pr filtres en mailles m talliques Caract ristiques lectriques nominales Tension et fr quence 120 V 60 Hz 2
4. 136518 1 7 Power Box Assembly 208418 1 208417S 1 20841909 208418 1 208417 1 Series Two Includes No 8 20 120V 60 Hz White Cover 240V 60 22 208419B gt 8 Switch 203321 1 203321 1 203321 1 203321 1 203321 1 10 F300 Power Supply Series 208045 1 208045G 1 208045G 208045G 1 208045G 1 Two 120V 60 Hz 240V 60 Hz N A N A N A N A N A 11 Interlock Bracket and Switch 4074 1 4074 1 4074ETG 1 4074ETG 1 4074ETG 1 12 W8600 Terminal Strip Supplied with W8600F 13 Terminal Board Assembly 203329B 1 203329B 1 N A N A 203329B 1 Front 14 e Board Assembly 203329A 1 203329A 1 N A 203329A 1 203329A 1 ear 17 Une Cord 4074ETD 1 4074ETD 1 4074ETD 1 4074ETD 1 4074ETD 1 19 Neon Assembly 4074EYS 1 4074EYS 1 4074EYS 1 4074EYS 1 4074EYS 1 20 Airflow Switch pin connection 4074ETH 1 4074ETH 1 4074ETH 1 4074ETH 1 4074ETH 1 20 Airflow Switch plug 4074EZB 1 4074EZB 1 N A 4074EZB 1 4074EZB 1 connection 21 Bag Assembly for cell 4074EHG 4074EHG 4074EHG 4074EHG 4074EHG repair Contains 2 Connector Clips 1 Terminal Board and instructions 22 Post Filter optional 50000293 001 50000293 002 50000293 004 50000293 003 50000293 004 p Series Two compatible with W8600F Use 203365A Conversion Kit for charging 120V 60 Hz model to 240V 60 Hz Change from brown cover to white cover as a running change U
5. To assure optimum performance from the air cleaner the cells and prefilters must be cleaned regularly and the postfilters replaced regularly every one to six months Washing frequency varies depending on the number of family members pets activities such as cooking or woodworking and smoking habits Use the Service Reminder Schedule at the end of this document to help establish and maintain a regular cleaning schedule Keep your Service Reminder Schedule in a convenient location NOTE Media postfilters should be replaced rather than cleaned See Replacing Media Postfilters section If the air cleaner has a W8600F Air Cleaner Monitor the SERVICE indicator activates to indicate filter and cell maintenance are due The time between activation of the SERVICE indicator is based on air cleaner run time that is selected by the installer at installation If the air cleaner has a W8600A AIRWATCH Indicator the Air Cleaner LCD arrow blinks to indicate it is time to service the cells and prefilters The time between activations of the Air Cleaner LCD is based on calendar time that is selected at installation 68 0240EF 5 12 NOTE let the heating or air conditioning system operate normally while the cells are being washed simply turn off the air cleaner switch IMPORTANT Vacuum the prefilter or brush or soak it in a tub Do not wash the prefilter in the dishwasher or car wash Automatic Dishwasher N CAUTION Burn Hazard
6. d bit d air peut tre mis hors service en d branchant le connecteur J3 de l interrupteur de d bit d air et en coupant le cavalier J8 du bloc d alimentation Voir la Fig 10 Q Brancher le filtre air lectronique directement dans la prise ayant la tension et la fr quence indiqu es Voir la Fig 10 pour observer le sch ma de raccordement interne REMARQUE Pour viter les risques de chocs lectriques le filtre poss de une fiche trois broches la troisi me broche sert de mise la terre Cette fiche ne peut tre utilis e qu avec une prise avec mise la terre Si la prise doit tre chang e faire installer la prise appropri e par un lectricien qualifi Ne pas le faire Soi m me Q Le filtre air lectronique peut aussi tre raccord l aide d un fil conducteur COLLECTEUR NOIR LANGUETTE DE CONTACT MF23413 Fig 10 Sch ma interne du filtre air lectronique avec le W8600F 1 Ouvrir la porte d acc s 2 Enlever les deux vis sur le devant et les deux vis sur le c t du bloc d alimentation Voir la Fig 11 68 0240EF 5 10 3 Dans le bloc d alimentation enlever les capuchons qui raccordent le cordon d alimentation au c blage du bloc d alimentation 4 Retirer le fil vert de la vis de mise la terre verte dans le compartiment de c blage Enlever le cordon d alimentation et le serre cable Placer le bouchon fourni dans l emballage sur le trou laiss par le cordon d alim
7. servir d un joint d tanch it pour boitier de filtre air offert en option pi ce 32002109 001 de mastic ou de ruban adh sif entoil Installer la clavette de la cellule dans la bonne direction La cellule lectronique doit toujours tre install e de facon que la section d ionisation soit du c t amont Une clavette de cellule install e en usine au bas du boitier permet d ins rer la cellule dans une seule direction Tant que la fl che moul e dans la clavette en plastique pointe dans la m me direction que le d bit d air l ionisateur restera du c t amont Si la position de la clavette doit tre invers e 1 Retirer la cellule lectronique 2 Desserrer la vis qui tient la clavette de la cellule en place Voir la Fig 8 FILTRE AIR LECTRONIQUE F300 CLAVETTE DE LA CELLULE AUTRES TROUS POUR LA CLAVETTE GUIDES DU PR FILTRE MF5639 Fig 8 La position de la clavette de la cellule d termine l orientation de la cellule la fleche de la clavette doit pointer vers l aval 3 Changer la clavette de position et la placer par dessus les trous oppos s La languette du bas s ins re dans le grand trou et la vis dans le plus petit trou S assurer que la fl che sur la clavette pointe dans la direction de l coulement de l air en aval 4 Serrer la vis dans le nouveau trou 5 Ins rer la cellule lectronique La section d ionisation sera maintenant du c t de l entr e d air en amo
8. BY LOCAL CODE TO USE SAME CIRCUIT ANY CONVENIENT HOUSE CIRCUIT CAN POWER AIR CLEANER REGARDLESS OF ELECTRICAL RATING OF HVAC SYSTEM M5707 Fig 12 Conduit connection for electronic air cleaner F300 ELECTRONIC AIR CLEANER OPERATION Large particles lint hair are caught by the prefilter As the dirty air passes through the intense high voltage electric field surrounding the ionizer wires all particles are given an electrical charge The air then moves through the collector part of the cell where alternate parallel plates are charged positively and negatively creating a uniform electrostatic field The charged particles are attracted to and collect on the plates that have the opposite electrical charge The air then passes through media postfilters removing additional particles from the air stream The air leaving the air cleaner has fewer particles Each time the air circulates through the electronic air cleaner more particles are removed CHECKOUT Inspect the Installation Make sure Turning vanes and transitions as needed are correctly installed Sheet metal joints between air cleaner and furnace are sealed All sheet metal connections are complete Original furnace filter has been removed and the blower compartment cleaned If atomizing humidifier is installed upstream from the air cleaner a disposable furnace filter is installed between the humidifier and the air cleaner Outside air if use
9. DE RECHANGE TABLEAU 3 VUE EXPLOSEE FIG 19 FILTRE A AIR ELECTRONIQUE F300 Ouverture nominale de la gaine de reprise 406 x 508 mm 406 x 635 mm 508 x 508 mm 508 x 635 mm N Description 16 x 20 po 16 x 25 po 20 x 20 po 20 x 25 po 1 Poste d acc s 32007528 003 32007528 003 32007528 002 32007528 002 2 Ensemble bouton d essai 203306AB 1 203306AB 1 203306AB 1 203306AB 1 3 Cellule lectronique FC37A1114 2 FC37A1130 2 FC37A1049 2 FC37A1064 2 4 Poign e de cellule 137266 2 137266 2 137266 1 137266 1 5 Pr filtre 209989 2 203371 2 203373 2 203372 2 6 Clavette de cellule 136518 1 136518 1 136518 1 136518 1 7 Bloc d alimentation avec n 208418J 1 2084175 1 208418H 1 208417R 1 8 20 120 V 60 Hz 8 Interrupteur 203321 1 203321 1 203321 1 203321 1 9 Couvercle de bloc 32004930 002 32004930 001 32004930 002 32004930 001 d alimentation et tiquette 10 Bloc d alimentation 120 V 208414 6 1 208414B 1 208414B 1 2084144 1 60 Hz 11 Patte et interrupteur de 4074ETG 1 4074ETG 1 4074ETG 1 4074ETG 1 verrouillage 12 Bornier du W8600 Fourni avec W8600F 13 Plaque pour bornier devant 203329B 1 203329B 1 203329B 1 203329C 1 14 Plaque pour bornier derri re 203329A 1 203329A 1 203329A 1 203329A 1 15 Plaque de s paration 203331 1 203331 1 203331 1 203331 1 16 Serre cable 203852 1
10. DOIT TRE V RIFI S PAR MENT CONSULTER LA NOTICE TECHNIQUE DU W8600F V RIFIER QUE LES CELLULES LECTRONIQUES SONT PROPRES S CHES ET CORRECTEMENT INSTALL ES S ASSURER QUE LES PR FILTRES M TALLIQUES SONT PLAC S DU C T DE L ARRIV E DE L AIR DANS LE FILTRE AIR ET QUE LES POST FILTRES LE CAS CH ANT SONT PLAC S DU C T OU L AIR SORT DU FILTRE AIR METTRE EN MARCHE LE FILTRE AIR PUIS METTRE EN MARCHE LE VENTILATEUR DU SYST ME DE CONDITIONNEMENT D AIR UARR T APPUYER SUR LE BOUTON D ESSAI SITU REMPLACER L ENSEMBLE VERIBIER DU SYSTEME SUR LA PORTE DU FILTRE A AIR ET LAMBE INTEBRUBTEUR SITU E SUR LE FILTRE AIR V RIFIER S IL SE PRODUIT UN CLAQUEMENT EN MARCHE APPUYER SUR LE BOUTON D ESSAI SITUE SUR LA PORTE METTRE L ARRET LE FILTRE A AIR R PARER LES CONTACTS DU FILTRE AIR ET V RIFIER RETIRER LA PORTE ET V RIFIER DU BOUTON D ESSAI S IL SE PRODUIT UN CLAQUEMENT SI LES CONTACTS DU BOUTON D ESSAI SONT EN BON TAT LE FILTRE AIR FONCTIONNE CORRECTEMENT RETIRER LES CELLULES EN LAISSANT LES PR FILTRES EN PLACE FERMER LA PORTE D ACC S ET METTRE INSPECTER LES CELLULES EN MARCHE LE FILTRE AIR ET V RIFIER CE QUI SUIT LES LAMES COLLECTRICES SONT ELLES PLI ES DES FILS D IONISATION EN MARCHE D VERIFIER LA LAMPE DU SYST ME SONTILS BRISES SITU E SUR LE FILTRE AIR Y DE LA SALET ACCUMUL E
11. EXPANSION DE 20 DEGR S DE CHAQUE C T PAR RACCORD 100 mm par 300 mm lin aires 4 po par pied lin aire GAINE DE REPRISE D AIR RACCORD DE TRANSITION BO TIER DU FILTRE AIR LECTRONIQUE 5626 Fig 4 Modifier encombrement de la gaine l aide de raccords de transition pour r duire la turbulence au minimum D flecteurs Si le filtre air est install pr s d un coude raccord angle installer les d flecteurs l int rieur du coude pour assurer une distribution d air plus uniforme la surface de la cellule Voir la Fig 5 Raccords de d rivation Si le raccord entre la gaine et l appareil dans le cas d une installation sur le c t offre un d gagement inf rieur 178 mm 7 po pour le bo tier du filtre air ajouter un raccord de d rivation au coude Voir la Fig 5 FILTRE AIR LECTRONIQUE F300 UTILISATION TYPIQUE DU RACCORD DE D RIVATION DE LA GAINE POUR ASSURER UN D GAGEMENT SUFFISANT POUR LE FILTRE AIR LECTRONIQUE RACCORD DE D RIVATION AU MOINS 178 mm 7 po A LES D FLECTEURS ASSURENT UNE MEILLEURE R PARTITION D AIR MF5627A Fig 5 Utilisation typique d un raccord de d rivation pour assurer un d gagement suffisant au filtre a air lectronique INSTALLATION Avant d installer ce produit 1 Lire attentivement les instructions Le fait de ne pas les suivre risque d endommager le produit ou de constituer un danger 2 V
12. Le filtre air peut tre mont dans n importe quelle position sauf la porte d acc s dirig e vers le bas Les positions du filtre air sur divers types d appareils de chauffage sont num r es ci apr s REMARQUE Pr voir un d gagement d au moins 330 mm 13 po entre la porte d acc s et tout obstacle pour faciliter la maintenance du post filtre du pr fil tre et de la cellule Appareil de chauffage caissons superpos s circulation ascendante Installation sur le c t Le filtre air est install la verticale l endroit entre l air repris sur le c t de l appareil de chauffage Voir la Fig 3A Appareil de chauffage caissons superpos s circulation ascendante Installation sous l appareil de chauffage le boitier du filtre air peut facilement soutenir l appareil de chauffage et le serpentin du syst me de refroidissement Le filtre air est install l horizontale l endroit entre l air repris au bas de l appareil de chauffage Voir la Fig 3B Appareil de chauffage caissons superpos s circulation ascendante Installation dans une armoire Le filtre est install la verticale sur l appareil de chauffage entre celui ci et l ouverture persiennes pour l air repris dans la porte de l armoire Voir la Fig 3C Appareil de chauffage caissons juxtapos s Le filtre air est install l horizontale dans le plenum d air repris juste au dessus de l appareil de c
13. access door Insert the tab on the bottom of the door into the slot in the cabinet then swing it closed and press into place The door must be firmly in place or the air cleaner will not operate Assure all wiring complies with local codes and ordinances The line voltage power source must match the voltage and frequency printed on the label inside the access door When the System fan comes on the Air Flow Switch AFS senses the negative pressure in the duct and turns on the power supply If power to the air cleaner is controlled by another switch the AFS can be disabled by disconnecting the AFS plug J3 and cutting the J8 jumper on the power supply See Fig 10 Plug the electronic air cleaner directly into the correct voltage and frequency outlet See Fig 10 for internal schematic The air cleaner operates correctly with any fan when wired with conduit or plugged in NOTE Toreduce the risk of electric shock this product has a Complete Wiring A WARNING Electric Shock Hazard Can cause personal injury Do not use an extension cord grounding type plug that has a third grounding pin This plug only fits into a grounding type power outlet If the plug does not fit into the outlet contact a quali fied electrician to install the proper outlet Do not change the plug in any way Alternatively the electronic air cleaner can be wired with conduit BLACK COLLECTOR POWER SUPPLY ORANGE NINTERLOCK SWIT
14. blower compartment so the air cleaner can help keep the blower motor and evaporator coils clean IMPORTANT Do not mount in the discharge air duct For most efficient air cleaning airflow must be spread evenly across the face of the air cleaner If the duct is a different size than the air cleaner cabinet gradual transitions are recommended If the duct turns sharply just before the air cleaner turning vanes are recommended Applications with Air Conditioning The air cleaner should be installed upstream from the evaporator coil The air cleaner will help keep the coil clean reducing maintenance 68 0240EF 5 F300 ELECTRONIC AIR CLEANER Applications with a Humidifier An evaporative humidifier can be mounted upstream from the air cleaner An atomizing humidifier should be mounted downstream from the air cleaner even though hard water salts will be blown into the living space and deposited as dust If an atomizing humidifier must be mounted upstream from the air cleaner 1 Mount it as far as possible upstream from the air cleaner 2 Install a standard disposable furnace filter between the humidifier and the air cleaner to trap water droplets and hard water salts 3 Frequently clean the air cleaner to prevent a hard water salt buildup NOTE The volume of water that is discharged from an atom izing humidifier can overload the air cleaner resulting in hard water salts being deposited as dust in the liv ing space Applica
15. lave vaisselle N MISE EN GARDE Danger de br lure Peut causer des blessures Laisser refroidir compl tement les cellules dans le lave vaisselle apr s le cycle de lavage ou porter des gants de caoutchouc pour viter les br lures De l eau chaude peut s accumuler dans les tubes qui soutiennent les plaques collectrices Incliner les cellules pour permettre a l eau de s couler 68 0240EF 5 12 IMPORTANT Consulter le manuel de l utilisateur fourni avec le lave vaisselle Des fabricants d conseillent de net toyer les cellules dans leur appareil Sile lave vaisselle comporte un bras de gicleur sup rieur et inf rieur placer les cellules de mani re permettre une bonne circulation de l eau Prendre garde d endommager les cellules en les plagant dans le lave vaisselle Les fils ionisants bris s etles plaques collectrices pli es ne sont pas couverts par la garantie Descellules tr s sales cause de la fum e de cuisson ou de tabac peuvent d colorer les pi ces en plastique et les parois de certains lave vaisselle Il n y a aucun risque pour la sant Laver les cellules plus fr quemment ou essayer une autre marque de d tergent pour r duire au minimum la d coloration NEPAS faire fonctionner le lave vaisselle au cycle de s chage car cela provoquerait l incrustation des contaminants qui n ont pas t enlev s durant le cycle de lavage et r duirait par le fait m me l efficac it du filtre 1 Pl
16. living area of the home where the display can be conveniently observed No wiring is necessary 68 0240EF 5 6 Choose Location Choose a location that is readily accessible for regular inspection and cleaning Allow at least 13 in 330 mm in front of the access door for removing the metal mesh prefilter media postfilter and electronic cell Allow enough room above the power supply so it can be serviced without removing pipes ducts or other heating system components The air cleaner must be installed where the temperature is between 40 to 125 F 4 to 52 IMPORTANT UV light can damage media postfilters Avoid installing UV lamp downstream of F300 in location where UV light illuminates postfilter Choose Mounting Position WARNING Heavy Equipment Hazard Can cause injury or equipment damage Do not mount air cleaner with access door facing down because the latch may not hold and the cell postfilter and prefilter can fall unexpectedly NOTE Nothing holds the cell postfilter and prefilter in place when the access door is opened The air cleaner can be mounted in any position except with the access door facing down A list of air cleaner mounting positions for a variety of furnace installations follows NOTE Atleast 13 in 330 mm clearance is required between the access door and any obstructions for cell postfilter and prefilter maintenance Upflow Highboy furnace Side installation air cleaner is
17. mounted vertically where return enters side inlet of furnace See Fig 3A Upflow Highboy furnace Installation beneath furnace air cleaner cabinet can easily support weight of furnace and air conditioner coil Air cleaner is mounted horizontally where return enters from below See Fig 3B Upflow Highboy furnace Closet installation Air cleaner is mounted vertically on furnace between furnace and louvered return air opening in closet door See Fig 3C Lowboy furnace Air cleaner is mounted horizontally in return plenum just above furnace opposite of supply plenum See Fig 3D Downflow Counterflow furnace Air cleaner is mounted horizontally in return duct or plenum just above furnace See Fig 3E High capacity system Two or more air cleaners can be used together See Fig 3F Horizontal furnace Air cleaner is mounted vertically where return enters See Fig 3G F300 ELECTRONIC AIR CLEANER M19777 Fig 3 Mounting positions with variety of furnace installations Determine Duct Design Requirements The air cleaner is adaptable to all new or existing forced air heating cooling and ventilating systems used in residential applications Transitions turning vanes or offsets may be needed in some applications for effective operation Transitions Transitions are needed when the duct is a different size than the air cleaner cabinet Gradual transitions reduce air turbulence and increase efficienc
18. possible 68 0240EF 5 FILTRE A AIR ELECTRONIQUE F300 Des fils de rechange sont offerts s par ment ils sont coup s a la bonne longueur et munis d ceillets aux deux extr mit s qui facilitent leur installation Voir la liste des pi ces et accessoires non illustr s pour connaitre le num ro de pi ce Pour proc der l installation 1 Accrocher le fil par l illet par dessus le connecteur ressort sur l un des rebords de la cellule voir la Fig 15 Prendre garde d endommager le connecteur ou toute autre partie de la cellule 2 Tenir l autre bout du fil l aide de pinces bec pointu et tirer le fil sur toute la longueur de la cellule Abaisser le connecteur situ sur le rebord oppos et accrocher le fil par l ceillet 3 V rifier s il y a des courts circuits l aide d un ohmme tre V rifier la r sistance entre le cadre de la cellule et les contacts de l ionisateur et de la plaque collectrice Dans chaque cas la r sistance devrait tre infinie Voir la Fig 16 REMPLACEMENT DES FILS IONISANTS CONNECTEURS ELASTIQUES APPUYER VERS LE BAS PINCE BEC DE CANARD MF1540B A ILS SONT MUNIS D OEILLETS AUX DEUX EXTR MIT S POUR FACILITER L INSTALLATION Fig 15 Remplacement d un fil d ionisateur 68 0240EF 5 14 BORNE DU COLLECTEUR BORNE DE L IONISATEUR BORNE DU COLLECTEUR DENG RA MF6155 F
19. qui cr e un champ lectrostatique uniforme Les particules ionis es sont attir es par les plaques ayant une charge contraire auxquelles elles adh rent la sortie du filtre air l air propre contient tr s peu de particules Chaque fois que l air circule dans le filtre air lectronique la quantit de particules dans l air diminue V RIFICATION V rifier l installation V rifier ce qui suit les d flecteurs et les raccords de transition sont bien install s les joints en t le entre le filtre air et l appareil de chauffage sont scell s tous les raccords en t le ont t pos s le filtre original a t retir et le compartiment du ventilateur a t nettoy siun humidificateur atomiseur est install en amont du filtre air un filtre jetable pour appareil de chauffage est install entre l humidificateur et le filtre air l air ext rieur s il y a lieu est m lang avec l air repris ou chauff au besoin avant d atteindre le filtre air 165 fl ches indiquant le sens de l coulement d air sur la cellule lectronique pointent vers le pr filtre en mailles m talliques est du c t amont de la cellule lectronique et le post filtre fibres est du c t aval de la cellule lectronique la poign e de la cellule fait face vers l ext rieur la cellule lectronique et le pr filtre sont propres et secs les raccordements du W8600F 51 y a li
20. tr s grand nombre de particules en suspension dans l air de 0 3 micron et plus qui le traversent Honeywell Filtre a air electronique F300 DONNEES TECHNIQUES CARACTERISTIQUES Post filtres a fibres qui permettent d obtenir une filtration am lior e Offert en cinq tailles qui conviennent la plupart des gaines d air s adapte l coulement d air d un c t ou de l autre D bit variant de 1 000 pi min 2 040 m h 2 000 pi min 3 400 m h selon la taille Bloc d alimentation semi conducteurs auto r gulateur qui maintient l efficacit de pointe du filtre air peu importe le degr d encrassement des cellules Perte de charge faible Moniteur de filtre air W8600F offert en option renseigne sur le rendement du filtre rappelle au propri taire de nettoyer les cellules de laver le pr filtre et de v rifier le syst me Indicateur sans fil cristaux liquides W8600A AIRWATCHM offert en option rappelle au propri taire quand laver les cellules Il rappelle galement quand remplacer les lampes UV et les crans vaporateurs de l humidificateur Boitier en acier galvanis prot geant l appareil contre la corrosion Lampe t moin au n on indiquant si le filtre air est en marche et sous haute tension Pr filtre qui prot ge les cellules contre les grosses particules de salet Bouton d essai qui permet de v rifier le fonctionnement du syst me
21. 203852 1 203852 1 203852 1 17 Cordon secteur 4074ETD 1 4074ETD 1 4074ETD 1 4074ETD 1 18 Bouchon 203847 1 203847 1 203847 1 203847 1 19 Lampe au n on 4074EYS 1 4074EYS 1 4074EYS 1 4074EYS 1 20 Interrupteur a d bit d air 4074ETH 1 4074ETH 1 4074ETH 1 4074ETH 1 21 Post filtre a fibres 50000293 001 50000293 002 50000293 003 50000293 004 22 Sachet FC37A pour 4074EHG 4074EHG 4074EHG 4074EHG r paration de la cellule Contient 2 pinces de connecteur 1 bornier et des directives 9 Utiliser une trousse de conversion 203365A pour convertir le bloc d alimentation 120 V 60 Hz en bloc d alimentation 240 V 60 Hz ou 220 1240 V 50 Hz Nombre quantit requise par appareil 5 0 ces pi ces ne sont pas vendues s par ment 17 68 0240EF 5 FILTRE A AIR ELECTRONIQUE F300 Nem QS 22 V 209 Fig 19 Composants du filtre air lectronique illustr mod le a deux cellules 68 0240EF 5 FILTRE A AIR ELECTRONIQUE F300 PIECES ET ACCESSOIRES NON ILLUSTRES TABLEAU 4 Description Ouverture nominale de la gaine de reprise 406 X 508 mm 16 x 20 po 406 x 635 mm 16 x 25 po 508 x 508 mm 20 x 20 po 508 x 635 mm 20 x 25 po Trousse avec joint d tanch it pour boitier de filtre a air 32002109 001 32002109 001 32002109 001 32002109 001 Fils d ionisa
22. 2550 2720 2890 3060 1900 3400 400 500 600 700 800 900 1000 1100 1200 1300 1400 1500 1600 1700 1800 3230 2000 CAPACIT EN m h pi3 min AVEC POST FILTRES 72 35 74 7 30 406 x 508 mm 16 x 20 in 622 9 508 x 318 mm 25 H 20 x 12 1 2 in 508 x 508 mm S 20 x 20 in 508 x 635 mm 49 7 M 20 x 25 in 20 406 x 635 mm z 16 x 25 in S 373 O 5 9 D D 249 u 10 D 124 05 0 680 850 1020 1190 1360 1530 1700 1870 2040 2210 2380 2550 2720 2890 3060 1900 3400 400 500 600 700 800 900 1000 1100 1200 1300 1400 1500 1600 1700 1800 3230 2000 CAPACIT EN m h pi min MINIMALE RECOMMAND E POUR LE MOD LE 508 x 318 mm 20 x 12 1 2 po CAPACIT MINIMALE RECOMMAND E POUR LES MOD LES 406 X 635 mm 16 x 25 po 508 x 508 mm 20 x 20 po 406 x 508 mm 16 x 20 po A capacit MINIMALE RECOMMAND E POUR LE MOD LE 508 x 635 mm 20 x 25 po S LECTIONNER LA TAILLE QUI CORRESPOND LE MIEUX L OUVERTURE DE REPRISE DE L APPAREIL DE CHAUFFAGE APPAREIL DE TRAITEMENT D AIR MF13654 Fig 1 Chute de pression par rapport au d bit d air Temp rature Ambiante Nominale En service 4 C 52 C 40 F 125 F Air traversant les cellules 4 C 52 C 40 F 125 F Temp rature maximale de lavage des cellules 140 C 220 F A l exp dition et l entreposage 40
23. 26 12 7 28 9 5 21 13 2 29 15 0 33 Er DIM E VOIR TABLEAU DIM B SE Voi TABLEAU TABLEAU 78 22 7 8 16 7 8 58 DIM C VOIR TABLEAU PLANIFICATION DE L INSTALLATION Application Le filtre air lectronique s installe dans la gaine de reprise d air d un syst me de chauffage de refroidissement ou de ventilation air puls Il retient un tr s grand nombre de particules en suspension dans l air de 0 3 micron et plus qui le traversent Tous les mod les disposent d un interrupteur d bit d air qui fait fonctionner le filtre air lorsque le ventilateur du syst me est en marche V rifier les exigences relatives l installation Installer le filtre air de mani re que tout l air qui passe dans le Syst me puisse circuler dans le filtre Le meilleur endroit est la gaine de retour d air c t du compartiment de ventilation cet endroit le filtre air contribuera en effet garder le moteur du ventilateur et les serpentins de l vaporateur plus propres IMPORTANT Ne pas installer le filtre air dans la gaine d air puls Le filtrage de l air sera plus efficace si le d bit d air est r parti uniform ment sur la surface du filtre Si la gaine et le boitier du filtre air n ont pas les m mes dimensions il est pr f rable d installer des raccords de transition Si la gaine pr sente un angle aigu juste avant le filtre air il est recommand d utilise
24. 40V 120Hz Peut tre converti en client le en un mod le de 240 V 60 Hz ou de 220 240 V 50 Hz au moyen de l ensemble 203365A Consommation d nergie 36 W maximum Appel de courant Voir le Tableau 1 Tension de l ionisateur 8 150 V c c Tension du collecteur 4 075 V c c POUR COMMANDER Tableau 1 Appel de courant Encombrement Nbre de Courant max A mm po cellules 120 V 220 240 V 406 x 635 16 x 25 2 0 4 0 2 508 x 635 20 x 25 2 0 4 0 2 406 x 508 16 x 20 2 0 4 0 2 508 x 508 20 x 20 2 0 4 0 2 508 x 318 20 x 12 1 2 1 0 4 0 2 D composition de l efficacit Les caract ristiques nominales de l efficacit proviennent de la norme American Society of Heating Refrigierating and Air Conditioning Engineers Standard 52 2 1999 Les pourcentages d efficacit sont d finis pour les petites particules 54 0 3 1 micron particules moyennes E gt 1 0 3 0 microns et les grosses particules 3 0 10 microns Tableau 2 D composition de l efficacit Avec post filtres fibres Sans post filtres fibres jusqu 81 492 pi jusqu 73 492 pi min min E jusqu 93 492 pi E jusqu 88 492 pi min min jusqu 99 492 pi min jusqu 95 96 492 pi min Au moment d acheter des produits de modernisation ou de remplacement aupr s de votre gro
25. 985 Douglas Drive North 35 Dynamic Drive Golden Valley MN 55422 Scarborough Ontario M1V 479 customer honeywell com Honeywell Marque de commerce d pos e aux E U 2006 Honeywell International Inc Tous droits r serv s aux Etats Unis sur du papier 68 0240EF 5 M S Rev 06 06 recycl contenant au moins 10 de fibres post consommation
26. A No in mm Cells 120V 220 240V 16x25 406x635 2 0 4 0 2 20x25 508 x 635 2 0 4 0 2 16x20 406 x 508 2 0 4 0 2 20 x 20 508 x 508 2 0 4 0 2 20 x 12 1 2 508 x 318 1 0 4 0 2 Fractional Efficiency Efficiency ratings are based on American Society of Heating Refrigerating and Air Conditioning Engineers Standard 52 2 1999 Efficiency ranges are defined for small particles 3 to 1 0 micron medium particles E 1 0 to 3 0 microns and large particles 3 0 to 10 0 microns Table 2 Fractional Efficiency With and Without Postfilter With postfilter Without postfilter E Up to 81 at 492 fom Up to 73 at 492 fpm E gt Up to 93 at 492 fom 2 Up to 88 at 492 Up to 99 at 492 E3 Up to 95 at 492 fom When purchasing replacement and modernization products from your TRADELINE wholesaler or distributor refer to the TRADELINE Catalog or price sheets for complete ordering number If you have additional questions need further information or would like to comment on our products or services please write or phone 1 Your local Honeywell Automation and Control Products Sales Office check white pages of your phone directory 2 Honeywell Customer Care 1885 Douglas Drive North Minneapolis Minnesota 55422 4386 In Canada Honeywell Limited Honeywell Limit e 35 Dynamic Drive Scarborough Ontario M1V 429 International Sales and Se
27. APACITY m hr A MINIMUM RECOMMENDED cfm FOR 20 x 12 1 2 in 508 x 318 mm MODEL RECOMMENDED cfm FOR 20 25 508 635 mm MODEL MINIMUM RECOMMENDED FOR 16 x 25 406 635 mm A SELECT SIZE THAT MOST CLOSELY FITS DIMENSIONS OF 20 x 20 in 508 x 508 mm 16 x 20 in 406 x 508 mm MODELS FURNACE AIR HANDLER RETURN AIR OPENING M13654 Fig 1 Pressure Drop Vs Airflow Temperature Ratings Weight Operating Ambient 40 to 125 F 4 to 52 C See Table 3 Temperature of Airflow Through Cells 40 to 125 F 4 to 52 Dimensions Maximum Cell Washing Temperature 220 F 140 C See Fig 2 Storage and Shipping Ambient Minus 40 F to plus 140 F SEDE minus 40 to plus 60 Approvals Mounting Underwriters Laboratories Inc Listed File E30954 Mounts in the return air duct of a forced air heating cooling or ventilating system Mount upstream from an atomizing humidifier See Planning the Installation section 3 68 0240EF 5 F300 ELECTRONIC AIR CLEANER Accessories 203365A Conversion Kit for changing 120V 60 Hz power supply to 240V 60 Hz or 220 240V 50 Hz W8600F Air Cleaner Monitor W8600A AIRWATCH Indicator Table 3 Shipping and Installed Weight Repair Parts See Replacement Parts Exploded View section Weight 16 x 20 in 16 x 25 in 20 x 12 1 2 in 20x 20 in 20 x 25 in 406 x 508 mm 406
28. CH AA SHORTING BAR FOR OZONE REDUCTION WA W2 W1 W3 A AIRFLOW SWITCH DISABLE JUMPER J8 AIRFLOW SWITCH PLUG J3 ZANEON LIGHT ZA optiona W8600F AIR CLEANER MONITOR RED IONIZER AIRFLOW SWITCH BOARD RED 3 LL CONTACT 7 41 Lr BLACK E d BROWN WHITE v 1 23413 Fig 10 Internal schematic for electronic air cleaner 68 0240EF 5 10 Open access door 2 Remove and retain the two screws from the front of the power box and the two screws from the sides of the power box See Fig 11 3 In the power box remove and retain two wire nuts that connect the line cord leads to the power box wiring Remove the power cord green lead from the green grounding screw on the wiring compartment barrier Remove the power cord and the strain relief Install the plug provided with the literature pack in the hole left by the power cord Attach conduit through a power box side knockout Wire the air cleaner directly to line voltage using wire nuts See Fig 12 Secure ground connection to the green ground screw on the wiring compartment barrier 9 Replace power supply cover and access door gt on eno REMOVING COVER FROM POWER BOX WIRING COMPARTMENT ELECTRONIC AIR CLEANER BLACK A POWER SUPPLY PROVIDE DISCONNECT MEANS AND OVERLOAD PROTECTION AS REQUIRED A THE AIR CLEANER CAN BE COMPLETELY ISOLATED FROM THE ELECTRICAL CIRCUIT OF THE HVAC SYSTEM UNLESS REQUIRED
29. Can cause personal injury Allow cells to cool completely in dishwasher at end of wash cycle or wear protective gloves to avoid burns Hot water can accumulate in the tubes supporting collector plates tip cells so tubes drain IMPORTANT Check the dishwasher owner s manual Some manufacturers do not recommend washing electronic cells in their dishwashers Ifthe dishwasher has upper and lower arms position the cells carefully to allow good water circulation Becareful to avoid damaging the cells when placing them in the dishwasher Broken ionizer wires or bent collector plates are not included in the warranty Very dirty cells especially from tobacco or cooking smoke can discolor the plastic parts and the lining of some dishwashers This discoloration is not harmful To minimize it wash the cells more frequently or try a different brand of detergent Donotallow the dishwasher to run through the dry cycle This bakes on any contaminants not removed during the wash cycle and reduces air cleaner efficiency 1 Putthe cells on the lower rack of the dishwasher with the airflow arrow pointing up It may be necessary to remove the upper rack Do not block water flow to the upper arm NOTE Lay a few large water glasses between the spikes on the lower rack and rest the cell s on them so the spikes do not damage the aluminum collector blades 2 Using regular dishwasher detergent allow the dish washer to run through the comple
30. DER SCHEDULE ELECTRONIC AIR CLEANER WASH REMINDER AND POSTFILTER REPLACEMENT SCHEDULE INSTALLATION DATE year J JJ JA S O 19779 68 0240EF 5 20 F300 ELECTRONIC AIR CLEANER ELECTRONIC AIR CLEANER TROUBLESHOOTING GUIDE TO USE THIS CHART FOLLOW THE STEPS IN ORDER DO NOT SKIP AROUND START EACH TIME A PROBLEM IS FIXED GO BACK TO START REPEAT ALL THE STEPS UNTIL THE AIR CLEANER CHECKS OUT OK NOTE IF AW8600F AIR CLEANER MONITOR IS CONNECTED TO THE AIR CLEANER DISCONNECT THE AIR CLEANER FROM THE W8600F BEFORE STARTING THIS PROCEDURE THE W8600F CAN BE CHECKED SEPARATELY SEE W8600F INSTRUCTION SHEET MAKE SURE ELECTRONIC CELLS ARE CLEAN DRY AND PROPERLY INSTALLED MAKE SURE METAL PREFILTERS ARE POSITIONED ON THE SIDE WHERE AIR ENTERS THE AIR CLEANER AND THAT POST FILTERS IF ANY ARE POSITIONED ON THE SIDE WHERE AIR LEAVES THE AIR CLEANER TURN THE POWER SWITCH ON THE AIR CLEANER ON AND TURN THE HVAC FAN ON PUSH TEST BUTTON ON THE AIR CLEANER DOOR AND LISTEN FOR SNAPPING SOUND CHECK THE SYSTEM LIGHT ON THE AIR CLEANER REPLACE LIGHT SWITCH ASSEMBLY TURN OFF AIR CLEANER POWER PUSH TEST BUTTON ON THE AIR CLEANER DOOR AND Ee REPAIR CONTACTS ON TEST BUTTON LISTEN FOR SNAPPING SOUND THE INSIDE OF THE TEST BUTTON ARE OK AIR CLEANER IS FUNCTIONING PROPERLY REMOVE THE CELLS LEAVE THE PREFILTERS IN P
31. EMENT Risque de choc lectrique Peut causer des blessures Seul un technicien qualifi devrait effectuer les tapes suivantes 2 La m thode suivante permettra de r duire la production d ozone d environ 20 25 mais elle diminuera l efficacit d environ 7 10 selon le d bit d air r el du ventilateur de l appareil de chauffage a D brancher le filtre air ou en couper l alimentation b Ouvrir la porte d acc s c Retirer le couvercle du bloc d alimentation Voir la Fig 17 d Rep rer la tige de court circuit J5 sur le bloc d alimentation Voir la Fig 18 L enlever et la raccorder une seule broche FILTRE AIR LECTRONIQUE F300 REMARQUE La production d ozone diminuera la tige de court circuit peut tre install e de nouveau au besoin e Remettre en place le couvercle du bloc d alimentation et la porte d acc s Mettre l appareil sous tension f R p ter les tapes de la v rification avant de quitter les lieux RETIRER LE BLOC D ALIMENTATION DU FILTRE AIR ET ENLEVER LE COUVERCLE MF20807 Fig 17 Retirer le bloc d alimentation du filtre air et retirer le couvercle 15 68 0240EF 5 FILTRE A AIR ELECTRONIQUE F300 J5 SHUNT IN OZONE REDUCTION POSITION J5 IN NORMAL POSITION 000000000 15099 Fig 18 D placer tige de coupe circuit J5 pour r duire la production d ozone d environ 20 a 25 68 0240EF 5 16 PIECES
32. EUT POSER UN RISQUE D INCENDIE LORS DE LA CONVERSION D UN FILTRE A AIR ELECTRONIQUE EN FILTRE A AIR A FIBRES LE BLOC D ALIMENTATION DOIT ETRE RETIRE OU MIS HORS SERVICE DE FA ON PERMANENTE MF13656 21 68 0240EF 5 FILTRE AIR ELECTRONIQUE F300 Honeywell Offrez a votre famille un air ambiant de meilleure qualit en faisant appel aux solutions Honeywell Confort et tranquillit d esprit seront au rendez vous Syst me de traitement d air aux ultraviolets lt liminez les microbes contenus dans l air et emp chez les spores de moisissures de cro tre sur les serpentins de refroidissement Filtre a air pour toute la maison Emprisonnez une bonne partie des particules contenues dans l air Humidificateur pour toute la maison Humidifiez l air trop sec maintenez l humidit ambiante pour r duire les effets n gatifs sur la sant b Syst me de r gulation par zones R glez la temp rature ambiante par zones pour plus de commodit et un confort accru changeur d air PerfectWindow A rez la maison pour que l air soit plus sain tout en r duisant la perte d nergie Thermostat programmable Economisez jusqu 30 du annuel de l nergie grace ce thermostat d installation facile selon l emplacement g ographique et l utilisation lt MF18621A Solutions de r gulation et d automatisation Honeywell International Inc Honeywell Limited Honeywell Limit e 1
33. LACE CLOSE THE ACCESS DOOR AND TURN ON THE AIR CLEANER POWER SWITCH INSPECT THE CELLS FOR BENT COLLECTOR PLATES BROKEN IONIZER WIRES CHECK THE SYSTEM LIGHT DIRT ACCUMULATION ON ON THE AIR CLEANER THE INSULATORS DAMAGED CONTACTS ON THE TERMINAL BOARD AT THE END OF THE CELL WARNING THIS STEP EXPOSES DANGEROUSLY HIGH VOLTAGE ONLY A QUALIFIED SERVICE TECHNICIAN SHOULD ATTEMPT REPLACE OR THIS STEP REPAIR CELLS CHECK FOR CORRECT INPUT VOLTAGE ACROSS P1 AND P2 TERMINALS ON POWER SUPPLY BOARD WITH AN OHMMETER CHECK FOR SHORT BETWEEN CELL FRAME AND IONIZER WIRES ELLA REPLACE AIR CLEANER POWER SUPPLY SHORT DETECTED REPLACE CELLS OK CELLS REPLACE AIR CLEANER POWER SUPPLY THIS AIR CLEANER PRODUCES A TRACE LEVEL OF OZONE AS A BY PRODUCT OF NORMAL OPERATION WHICH IS WELL UNDER THE LIMIT PRESCRIBED BY THE U S F D A PLEASE REFER TO YOUR OWNERS MANUAL FOR FURTHER INFORMATION FOR A REPLACEMENT OWNERS MANUAL CALL 1 800 468 1502 OR VISIT http yourhome honeywell com WARNING INCORRECT CONVERSION TO MEDIA AIR CLEANER CAN CAUSE FIRE HAZARD WHEN CONVERTING AN ELECTRONIC AIR CLEANER TO A MEDIA AIR CLEANER THE POWER SUPPLY MUST BE REMOVED OR PERMANENTLY DISABLED M13656 Fig 20 Troubleshooting Guide 21 68 0240EF 5 F300 ELECTRONIC AIR CLEANER Honeywell Choose better indoor air for your family by installing Honeywell solutions You ll en
34. Proud Partner AMERICAN LUNG ASSOCIATION MHEALTH HOUSE Honeywell 9 B APPLICATION The F300 Electronic Air Cleaner is mounted in the return air duct of a forced air heating cooling or ventilating system It captures a significant amount of the airborne particles 0 3 micron and larger from air circulated through it Honeywell F300 Electronic Air Cleaner PRODUCT DATA FEATURES Media postfilters optional provide enhanced filtration Available in five sizes to fit most ducts adapts to airflow from either side Capacity varies from 1000 cfm 2040 m hr to 2000 cfm 3400 m hr depending on size Solid state power supply is self regulating and maintains peak efficiency during a wide range of cell dirt loading conditions Low pressure drop Optional W8600F Air Cleaner Monitor indicates air cleaner performance reminds homeowner when filter and cell maintenance are due and when to check the system Optional wireless W8600A AIRWATCH LCD indicator provides reminder when air cleaner electronic cells need washing when media postfilters need replacing when UV lamps need replacing and when humidifier pad needs replacing Galvanized cabinet protects against rust Neon light next to on off switch tells if air cleaner is powered and if high voltage is present Prefilter screens protect cells from large dirt particles Test button checks system operation Contents
35. SUR LES ISOLATEURS DES CONTACTS DU BORNIER SUR LE REBORD DES CELLULES SONT ILS ENDOMMAG S AVERTISSEMENT LA TENSION LECTRIQUE EST TR S LEV E CETTE TAPE ET PR SENTE UN DANGER SEUL UN TECHNICIEN QUALIFI DEVRAIT EX CUTER CETTE TAPE REMPLACER OU R PARER LES CELLULES V RIFIER SI LA TENSION D ALIMENTATION EST BONNE AUX BORNES P1 ET P2 DE LA CARTE CORRIGER LE RACCORDEMENT AVEC UN OHMMETRE V RIFIER S IL Y AUN D ALIMENTATION COURT CIRCUIT ENTRE LE CADRE DE LA CELLULE ET LES FILS D IONISATION LE CADRE DE LA CELLULE ET LES LAMES DU COLLECTEUR REMPLACER LE BLOC D ALIMENTATION DU FILTRE COURT CIRCUIT D TECT AUCUN COURT CIRCUIT REMPLACER LES CELLULES LES CELLULES FONCTIONNEMENT CORRECTEMENT REMPLACER LE BLOC D ALIMENTATION DU FILTRE A AIR CE FILTRE A AIR PRODUIT DE L OZONE EN QUANTITE NEGLIGEABLE COMME SOUS PRODUIT DU FONCTIONNEMENT NORMAL DE L APPAREIL LES QUANTITES PRODUITES SONT LARGEMENT INFERIEURES AUX LIMITES PREVUES PAR L AGENCE FEDERALE AMERICAINE POUR LE CONTROLE DES PRODUITS ALIMENTAIRES ET PHARMACEUTIQUES FDA PRIERE DE CONSULTER LE GUIDE DE L UTILISATEUR POUR OBTENIR D AUTRES RENSEIGNEMENTS POUR OBTENIR UN GUIDE DE L UTILISATEUR POUR LE REMPLACEMENT COMPOSER LE 1 800 468 1502 OU SE RENDRE L ADRESSE http yourhome honeywell com AVERTISSEMENT LA CONVERSION INCORRECTE DU FILTRE A AIR ELECTRONIQUE EN FILTRE A AIR A FIBRES P
36. acer les cellules dans le panier inf rieur du lave vaisselle la fl che de d bit d air pointant vers le haut S il y a lieu enlever le panier sup rieur Ne pas blo quer la circulation de l eau dans le gicleur sup rieur CONSEIL Installer de grands verres eau entre les tiges du panier inf rieur pour y appuyer les cellules Ainsi les tiges n abimeront pas les pales en aluminium du collecteur 2 Utiliser le d tergent qui convient le mieux votre lave vaisselle Faire fonctionner le lave vaisselle pendant un cycle de lavage et de ringage complet Ne pas utiliser le cycle de s chage Afin d viter les br lures laisser refroidir compl tement les cellules avant de les sortir ou porter des gants de protection Il peut y avoir de l eau l int rieur des plaques des cellules Incliner les cellules pour permettre l eau de s couler 3 Prendre un chiffon propre et avec le pouce et l index essuyer les fils ionisants et le panneau de contacts l extr mit de la cellule 4 V rifier le lave vaisselle S il y a des r sidus et de la salet dans le lave vaisselle une fois le filtre enlev le faire fonctionner de nouveau pendant un cycle de lavage ou de rincage S il semble y avoir trop de salet ou de r sidus nettoyer les cellules plus souvent ou employer un autre d tergent Nettoyage des cellules dans un bac N MISE EN GARDE Produit chimique dangereux Peut causer des blessures Eviter d clabousser la so
37. d is mixed with return air or heated as necessary before it can reach the air cleaner Airflow arrows on the electronic cell point downstream Metal mesh prefilter is on the upstream side and media postfilter is on downstream side of the cell Cell handle faces outward Electronic cell and prefilter are clean and dry W8600F wiring connections are correctly made 68 0240EF 5 F300 ELECTRONIC AIR CLEANER Check Air Cleaner Operation With all components in place turn on air cleaner switch and energize system blower Check following points of operation The neon light next to the On Off switch is on The neon light shows that the air cleaner is energized and the high voltage power supply is working correctly If a W8600F is part of the installation also check the wall panel and make sure the On indicator is lit The W8600F Fault indi cator comes on if there is a problem with the high voltage power supply 2 Turn off the system blower The neon light should go off after a few seconds 3 Turn on the system blower With the air cleaner ener gized push the test button A snapping sound indicates that the collector voltage is present on the cell 4 With a multispeed blower repeat steps 1 through 3 for each fan speed SERVICE N CAUTION Sharp Edges Can cause personal injury Carefully handle the cell s or wear protective gloves to avoid cuts from the sharp metal edges Cleaning the Cells and Prefilters
38. e l indicateur AIRWATCHVP w8600A L indicateur W8600A peut tre install pr s du thermostat ou tout autre endroit de la maison d ou l on peut bien voir les voyants Aucun c blage requis Choix de l emplacement Choisir un emplacement permettant de faire facilement la v rification et le nettoyage normaux du filtre Pr voir un d gagement d au moins 330 mm 13 po l avant de la porte d acc s pour retirer le pr filtre et la cellule Pr voir suffisamment d espace au dessus du bloc d alimentation pour faire la maintenance sans avoir enlever les tuyaux les gaines ou d autres composants du syst me de chauffage Le filtre doit tre install un endroit la temp rature se situe entre 4 C et 52 C 40 F 125 F IMPORTANT La lampe UV peut endommager les post filtres fibres Eviter de placer la lampe UV en aval du F300 l endroit la lampe UV claire le post filtre 68 0240EF 5 FILTRE A AIR ELECTRONIQUE F300 Choix de la position d installation A AVERTISSEMENT Equipement lourd Peut causer des blessures ou endommager l quipement Ne pas installer le filtre air de sorte que la porte d acc s soit dirig e vers le plancher Sila porte d acc s fait face au plancher le verrou pourrait se d tacher et la cellule le pr filtre et le post filtre pourraient tomber brusquement REMARQUE La cellule le pr filtre et le post filtre ne sont pas retenus lorsque la porte est ouverte
39. e propre et y placer les cellules et les pr filtres pendant 5 15 minutes Rincer jusqu ce que l eau qui s coule ne soit plus glissante 6 Tremper les cellules ou les pr filtres dans une eau claire pendant 10 minutes pour un dernier ringage 7 Prendre un chiffon propre et avec le pouce et l index essuyer les fils ionisants et le panneau de contacts l extr mit de la cellule Nettoyage des cellules dans un lave auto Utiliser le tuyau du lave auto libre service encaissement automatique pour nettoyer les cellules Tenir le gicleur au moins 2 pieds de la cellule pour viter que le jet d eau haute pression ne l endommage fils d ionisation bris s ou plaques collectrices pli es Suivre les m mes tapes de lavage et de rincage que pour les voitures Toutefois il ne faut pas cirer les cellules S assurer de rincer jusqu ce que l eau qui s coule des cellules ne soit plus glissante 13 FILTRE AIR LECTRONIQUE F300 HIGH VELOCITY DETERGENT SPRAY gt 20831 Fig 14 Nettoyage des cellules dans un lave auto Remise en place des pr filtres et des cellules 1 V rifier les cellules afin de s assurer qu aucun fil n est bris ni qu aucune plaque collectrice n est d form e Faire les r parations ou amener l appareil un atelier de r paration autoris Honeywell 2 Glisser les pr filtres dans les guides vers l amont 3 Glisser les cellules l int rieur de sorte q
40. entation Relier le fil conducteur par l ouverture d fongable sur le c t du bloc d alimentation Raccorder le filtre air directement au fil tension secteur l aide des capuchons Voir la Fig 12 Replacer le fil de mise la terre sur la vis de mise la terre verte dans le compartiment de c blage Replacer le couvercle du bloc d alimentation et la porte d acc s RETRAIT DU COUVERCLE DU BLOC D ALIMENTATION MF20806 Fig 11 Retrait du couvercle du bloc d alimentation COMPARTIMENT DE CABLAGE LA L1 SOUS TENSION FILTRE A AIR ELECTRONIQUE A ALIMENTATION FOURNIR UN DISPOSITIF DE COUPURE ET UNE PROTECTION CONTRE LES SURCHARGES AU BESOIN A LE FILTRE AIR PEUT ETRE ISOLE ENTIEREMENT DU CIRCUIT DU SYSTEME DE CONDITIONNEMENT D AIR A MOINS QUE LES CODES LOCAUX EXIGENT L UTILISATION DU CIRCUIT TOUT CIRCUIT LECTRIQUE RESIDENTIEL PEUT ALIMENTER LE FILTRE AIR IMPORTE LES CARACTERISTIQUES NOMINALES DU SYSTEME DE CONDITIONNEMENT D AIR MF5707 Fig 12 Connexion des conducteurs du filtre air lectronique FILTRE AIR LECTRONIQUE F300 FONCTIONNEMENT Les grosses particules charpie poils sont retenues par le pr filtre L air pollu passe dans le champ lectrique haute tension autour des fils ionisants Toutes les particules re oivent une d charge lectrique L air passe ensuite dans les plaques collectrices qui sont simultan ment positives et n gatives ce
41. eu sont bien faits V rifier le fonctionnement du filtre air Une fois tous les composants en place mettre sous tension le filtre air et le ventilateur du syst me V rifier les points suivants 1 La lampe t moin pr s de l interrupteur est allum e Si le filtre comprend un W8600F v rifier galement le panneau mural et s assurer que le voyant ON est allum Le voyant FAULT du W8600F s allumera s il y a un probl me d alimentation haute tension 2 Fermer le ventilateur du syst me La lampe t moin devrait s teindre apr s quelques secondes La lampe t moin indique que le filtre air est en marche et que l alimentation haute tension fonctionne normalement 3 Remettre le ventilateur sous tension Lorsqu il est sous tension appuyer sur le bouton d essai Un bruit sec indique que la tension du collecteur est pr sente dans la cellule 4 Avecun ventilateur vitesses multiples r p ter les tapes 1 et 2 pour chaque vitesse 68 0240EF 5 FILTRE A AIR ELECTRONIQUE F300 MAINTENANCE MISE EN GARDE Rebords coupants Peut causer des blessures Manipuler les cellules avec soin ou porter des gants de protection pour viter les coupures sur les rebords de m tal coupants Nettoyage des cellules et des pr filtres Pour assurer le rendement optimal du filtre il faut laver les cellules et les pr filtres r guli rement tous les 1 6 mois La fr quence de lavage d pend du nombre de personnes et d ani
42. hance your comfort and peace of mind Ultraviolet Air Treatment Systems Zap airborne germs and prevent mold spore growth air conditioning coils Whole House Air Cleaners Trap a high percentage of airborne particles of the air passing through it Whole House Humidifiers Moisturize air 40 to 60 humidity is ideal for minimizing adverse health effects Zoning Systems NC Control temperature by area in your home saving energy and improving comfort TIT PerfectWindow Air Exchangers 8 Ventilate your home to assure fresh air while minimizing energy loss Programmable Thermostats Save up to 30 in annual energy costs with this easy to use thermostat depending on geography and usage M18621 Automation and Control Solutions Honeywell International Inc Honeywell Limited Honeywell Limit e 1985 Douglas Drive North 35 Dynamic Drive Golden Valley MN 55422 Scarborough Ontario M1V 429 customer honeywell com Honeywell U S Registered Trademark Piintedin 2006 Honeywell International Inc paper containing at least 10 68 0240EF 5 M S Rev 06 06 post consumer paper fibers Proud Partner AMERICAN LUNG ASSOCIATION FIHEALTH HOUSE APPLICATION Le filtre a air lectronique F300 s installe dans la gaine de reprise d air dans un syst me de chauffage de refroidissement ou de ventilation air puls Il retient un
43. hauffage face au ple num d alimentation Voir la Fig 3D Appareil de chauffage contre courant circulation descendante Le filtre air est install l horizontale dans la gaine de reprise d air ou dans le plenum juste au dessus de l appareil de chauffage Voir la Fig 3E Syst me haut rendement Il est possible de combiner deux ou plusieurs filtres air Voir la Fig 3F Appareil de chauffage horizontal Le filtre air est mont la verticale l endroit entre l air repris Voir la Fig 3G M19777 Fig 3 Positions du filtre air sur divers types d appareils de chauffage 68 0240EF 5 6 Raccords de gaines requis Le filtre air se combine a tout syst me r sidentiel de chauffage de refroidissement et de ventilation air puls neuf ou en place Des raccords de transition ou de d rivation et des d flecteurs peuvent tre n cessaires pour assurer un meilleur rendement dans certaines applications Raccords de transition Des raccords de transition sont n cessaires lorsque les dimensions de la gaine et du bo tier du filtre air sont diff rentes Les raccords de transition r duisent la turbulence et augmentent l efficacit L expansion maximale doit tre de 20 degr s environ 100 mm par 300 mm lin aires 4 po par pied lin aire de chaque c t du raccord de transition Voir la Fig 4 MODIFIER L ENCOMBREMENT DE LA GAINE AVEC DES RACCORDS DE TRANSITION POUR MINIMISER LA TURBULENCE
44. i re d articulation de la porte d acc s Q Fixer solidement le bo tier l appareil de chauffage soit directement voir illustration soit l aide d un collier de d marrage dans l appareil de chauffage Percer des trous et fixer l appareil l aide de rivets ou de vis pour t le ou utiliser des crous coulissants Voir la Fig 6 68 0240EF 5 8 SOLA M20804 Fig 6 Fixer le boitier l appareil de chauffage Installer les d flecteurs Q Installer les d flecteurs l int rieur du coude raccord angle mont directement sur le boitier du filtre air Voir la Fig 7 Fixer le boitier au systeme de gaines Q Installer un raccord de transition si les ouvertures du boitier du filtre air et de la gaine sont de dimensions diff rentes Voir la Fig 4 Q Fixer l autre c t du boitier sur le coude l aide de rivets de vis pour t le ou d crous coulissants au besoin S il faut percer des trous utiliser une pince tau pour maintenir l appareil en place pendant le percage Voir la Fig 7 PINCE ETAU MF20815 Fig 7 Fixer la gaine d air au filtre air Noter la position des d flecteurs La pince tau sert tenir ensemble l appareil et la gaine d air pendant l installation Sceller les joints Sceller tous les joints du syst me de reprise d air entre le filtre air et l appareil de chauffage pour emp cher la poussi re de p n trer dans le courant d air propre Se
45. ig 16 Utiliser un ohmm tre pour v rifier s il y a des courts circuits dans la cellule R duction de l odeur d ozone MISE EN GARDE Risque de choc lectrique Peut causer des blessures Toujours couper l alimentation et ouvrir la porte d acc s avant de soulever le couvercle du bloc d alimentation Le filtre air lectronique produit une petite quantit d ozone lorsqu il fonctionne normalement Pendant les deux premi res semaines de fonctionnement la quantit d ozone est parfois plus lev e cause des extr mit s tranchantes des nouvelles pi ces m talliques haute tension Si elles fonctionnement normalement les pi ces seront rod es en peu de temps En g n ral on peut d celer l odeur d ozone dans des concentrations aussi faibles que 0 003 0 010 partie par millions ppm Le filtre air lectronique produit de 0 005 0 010 ppm d ozone l int rieur La U S Food and Drug Administration et Sant et bien tre social Canada recommandent que la concentration d ozone l int rieur ne d passe pas 0 050 ppm titre indicatif la concentration d ozone dans la plupart des grandes villes atteint parfois 0 100 ppm Toutefois il est possible de r duire la quantit d ozone produite par le filtre air de deux fagons 1 En installant un filtre charbon actif en aval du filtre air S assurer que les particules provenant de l l ment fil trant ne tombent pas dans le filtre air A AVERTISS
46. ing upstream side of the cabinet Attach Cell Handles Cell handles included with the air cleaner must be installed on the end of the cell closest to the access door To install 1 Orientthe cell as it will be when installed The gray contact board must be up and the airflow arrow stamped into the cell must point downstream 2 Hold the handle sideways and insert the solid tab on the back of the handle into the slot in the cell Turn the handle 90 degrees clockwise to align the divided tab with the square hole See Fig 9 INSTALL HANDLE ON END OF CELL CLOSEST TO ACCESS DOOR ROTATE 90 DEGREES FOLD TAB TO LOCK HANDLE IN PLACE M6047A Fig 9 Install the handle on the end of the cell closest to the access door 3 Insert the divided tab into the square hole 4 Fold up the wedge and insert it into the divided tab to lock the handle in place If necessary press with a blunt instrument like the end of a pliers 68 0240EF 5 F300 ELECTRONIC AIR CLEANER Reassemble Air Cleaner Insert the electronic cells with the gray contact board toward the power supply and the airflow arrow pointing downstream If the cell does not slide easily into the cabinet check the orientation of the cell key Q Insert the metal mesh prefilters on the upstream side of the cabinet in the guide provided Q Insert the media postfilters on select models on the downstream side of the cabinet in the guide provided L Replace the
47. ion See Parts and Accessories Not Illustrated section To install 1 Hook the eyelet on one end of the wire over the spring connector on one end of the cell See Fig 15 Be careful to avoid damaging spring connectors or other parts of the cells 2 Hold the opposite eyelet with a needle nose pliers and stretch the wire the length of the cell Depress the opposite spring connector and hook the eyelet over it 3 Check the cell for short circuits using an ohmmeter see Fig 16 Check the resistance between the frame of the cell and both the ionizer and the collector contacts In each case the resistance should be infinite REPLACING AN IONIZER WIRE PRESS SPRING CONNECTORS E NN CA NEEDLENOSE PLIERS IONIZER WIRE A TWO EYELETS HOLD IONIZER WIRE TO CELL 15408 Fig 15 Replacing ionizer wire 68 0240EF 5 14 COLLECTOR TERMINAL IONIZER TERMINAL COLLECTOR TERMINAL NP i B B TARRY MAMA AU UNK ME Mag DI D VRUM si Fig 16 Use ohmmeter to check electronic cells for short circuits Modification to Reduce Ozone Odor N CAUTION Electric Shock Hazard Can cause personal injury Always disconnect power and open access door before opening power supply cover The electronic air cleaner generates a small amount of ozone in normal operation During the first week or two of operation
48. lution dans les yeux Porter des gants de caoutchouc afin d viter tout contact prolong du d tergent avec la peau Garder la solution de d tergent hors de port e des enfants REMARQUE Toujours nettoyer les cellules en premier lieu afin que les charpies lourdes provenant des pr filtres ne p n trent dans les cellules Laver les pr filtres ensuite 1 Utiliser un bac suffisamment grand pour y plonger une ou deux cellules comme une cuve de lavage ou une poubelle REMARQUE Les angles vifs de la cellule peuvent gratigner la baignoire 2 Verser une quantit suffisante d eau chaude pour couvrir les cellules Dissoudre environ 3 4 de tasse de d tergent pour lave vaisselle Si le d tergent ne se dissout pas imm diatement ou s il y a de l cume la surface de l eau employer une autre marque de d tergent ou une eau adoucie 3 Lorsque le d tergent est enti rement dissout placer les cellules dans le bac et laisser tremper de 15 20 minutes Agiter les cellules de haut en bas quelques reprises et les retirer de l eau Voir la Fig 13 PORTER DES GANTS DE CAOUTCHOUC AFIN D VITER TOUT CONTACT PROLONG DE LA SOLUTION AVEC LA 6 MF922A Fig 13 Nettoyage des cellules dans un bac 4 Nettoyer les pr filtres de la m me mani re Vider et net toyer le bac 5 Rincer les cellules et les pr filtres en les vaporisant d eau tr s chaude rincer le bac et le remplir d eau chaud
49. maux dans la maison des activit s cuisson ou travaux de menuiserie par exemple et de la fum e de tabac A l aide du calendrier de rappel de lavage fournie la derni re page du pr sent document tablir un horaire de lavage et le suivre Placer la fiche un endroit pratique REMARQUE Les post filtres fibres devraient tre rem plac s plut t que nettoy s Consulter la section Remplacement des post filtres fibres Si le filtre air comprend un moniteur de filtre air W8600F le voyant SERVICE s allumera pour indiquer que les cellules et les pr filtres doivent tre nettoy s L intervalle entre chaque lavage d pend du temps de fonctionnement du filtrequi a t choisi par l installateur au moment de l installation Si le filtre air comprend un indicateur AIRWATCHMD 8600 la fl che Air Cleaner filtre air clignotera pour indiquer qu il est temps de laver les pr filtres et les cellules L intervalle entre chaque moment la fl che s allume d pend du temps de fonctionnement du filtre qui a t choisi au moment de l installation REMARQUE Le syst me de chauffage ou de refroidissement peut continuer fonctionner pendant le lavage des cellules faut seulement mettre l interrupt eur du filtre air OFF IMPORTANT Nettoyer les pr filtres l aspirateur ou la brosse ou les tremper dans un bac Ne pas les laver dans un lave vaisselle ou un lave auto Nettoyage des cellules dans le
50. may need to alter the procedure to fit your application Q Remove and set aside the access door electronic cells metal mesh prefilters and media postfilters Q Align the cabinet with the return air opening Create opening in furnace to match air cleaner cabinet opening Q Install a transition when the furnace and air cleaner openings are different sizes See Fig 4 Place blocks under the cabinet so the unit is firmly supported and level The 5 8 in 16 mm mounting foot on the cabinet hinge plate provides the minimum clearance required for the access door hinge Q Attach the cabinet securely to the furnace The unit can be attached directly as shown or a starting collar can first be fitted in the furnace opening Either drill holes and fasten with sheet metal screws or rivets or use slip joints See Fig 6 M20804 Fig 6 Fasten cabinet to furnace Install Turning Vanes Mount turning vanes inside the elbow or angle fitting that is directly against the air cleaner cabinet See Fig 7 Fasten Cabinet To Ductwork Q Install a transition when the opening in the air cleaner cabinet and the duct are different sizes See Fig 4 Q Fasten the other side of the cabinet to the elbow using sheet metal screws rivets or slip joints as appropriate If drilling holes use locking pliers to help hold the unit in place during drilling See Fig 7 47 VANES LOCKING PLIERS M20815 Fig 7 Connect duc
51. n actual airflow deliv e Replace the power supply cover and access door ered by the furnace blower Turn on the power f Repeat checkout procedure before leaving the job REMOVE POWER BOX FROM AIR CLEANER AND REMOVE THE COVER M20807 Fig 17 Remove power box from air cleaner and remove cover 15 68 0240EF 5 F300 ELECTRONIC AIR CLEANER J5 SHUNT IN OZONE REDUCTION POSITION J5 IN NORMAL POSITION 4 o oE2 J3 DEI 15099 Fig 18 Move J5 shorting to reduce ozone production about 20 to 25 percent 68 0240EF 5 16 F300 ELECTRONIC AIR CLEANER REPLACEMENT PARTS TABLE 4 EXPLODED VIEW FIG 19 Table 4 Replacement Parts Nominal Return Air Opening 16 x 20 in 16 x 25 in 20 x 12 1 2 in 20 x 20 in 20 x 25 in No Description 406 x 508 mm 406 x 635 mm 508 x 318mm 508 508 mm 508 x 635 mm 1 F300 Door includes No 2 32007528 003 32007528 003 N A 32007528 002 32007528 002 2 Test Button Assembly 137980A 1 137980A 1 137980A 1 137980A 1 137980A 1 3 Electronic Cell FC37A1114 2 7 1130 2 7 1064 1 7 1049 2 FC37A1064 2 4 Cell Handle 137266 2 137266 2 137266 1 137266 2 137266 1 5 Prefilter without spring clips 209989 2 203368 2 203369 1 203370 2 203369 2 6 Cell Key 136518 1 136518 1 136518 1 136518 1
52. nt du boitier Fixer les poign es des cellules Les poign es de la cellule doivent tre install es l extr mit de la cellule qui est la plus pr s de la porte d acc s Installation 1 Orienter la cellule dans la direction d sir e pour l installation Le panneau de contacts gris doit pointer vers le haut et la fl che indiquant le sens d coulement d air de la cellule doit pointer vers l aval 2 Tenirla poign e par les c t s et ins rer la languette rigide sur le dos de la poign e dans la fente de la cellule Tourner la poign e de 90 en sens horaire pour aligner la languette divis e sur le trou carr Voir Fig 9 INSTALLER LES POIGN ES AU BOUT DE LA CELLULE QUI EST LA PLUS PRES DE LA PORTE D ACCES TOURNER 90 DEGR S PLIER LA LANGUETTE POUR VERROUILLER LA POIGNEE EN PLACE MF6047A Fig 9 Installer les poign es au bout de la cellule qui est la plus pr s de la porte d acc s 3 Ins rer la languette divis e dans le trou carr 4 Plier la cale et l ins rer dans la languette divis e pour verrouiller la poign e en place Au besoin exercer une pression avec un instrument mouss comme une paire de pinces 68 0240EF 5 FILTRE A AIR ELECTRONIQUE F300 R assembler le filtre air Ins rer la cellule lectronique de fa on que le panneau de contacts gris soit orient vers le haut et que la fl che indiquant le sens d coulement d air pointe vers laval Si la cellule ne gli
53. nutes Agitate up and down a few times and remove See Fig 13 WEAR GLOVES TO PROTECT HANDS FROM DETERGENT 8 Fig 13 Washing cells in container 4 Next wash the prefilters the same way Empty and rinse the wash container 5 Rinse the cells and prefilters with a hard spray of very hot water rinse the tub clean then fill the tub with clean hot water and soak for 5 to 15 minutes Rinse until the water draining from the cells and prefilters no longer feels slippery 6 Soak cells and prefilters in a final clear water rinse for ten minutes 13 F300 ELECTRONIC AIR CLEANER 7 Wipe ionizer wires and contact board on end of cell using your thumb and forefinger with a small damp cloth Washing Cells at the Car Wash Use the hand sprayer at a coin operated do it yourself car wash to clean the cells Hold the nozzle at least two feet away from the unit to avoid damage such as broken ionizer wires or bent collector plates from the high pressure stream of water See Fig 14 Follow the same sequence of wash and rinse as recommended for cars However do not wax the cells Be sure to rinse until the water draining from the cells no longer feels slippery HIGH VELOCITY DETERGENT SPRAY M20831 Fig 14 Washing cells at car wash Reinstall the Cells and Prefilters 1 Inspect the cells for broken ionizer wires and bent collec tor plates Repair as necessary or take to a H
54. oneywell Authorized Air Cleaner Repair Station 2 Slide the prefilters into the upstream prefilter guides 3 Slide in the air cleaner cells so the airflow arrow points downstream and the handles faces outward 4 Firmly close the access door 5 Turn on the air cleaner If the cells and prefilters are wet the neon light may not come on and you may hear arcing If the arcing is annoying simply turn off the air cleaner for two to three hours or until the cells are dry Replacing Media Postfilters To maximize the filtration efficiency of the media postfilters replace them every six months Replacement filters are available in the same size and configuration as the original unit Contact your local Honeywell distributor to purchase replacement filters Install the replacement filters exactly as the filters provided with the equipment Use the Service Reminder Schedule at the end of this document to help you establish and maintain a regular replacement schedule Keep your Service Reminder Schedule in a convenient location 68 0240EF 5 F300 ELECTRONIC AIR CLEANER Replacing lonizer Wires Broken or bent ionizer wires can cause an electrical short to ground often resulting in visible arcing or sparking Do not use cells until broken wires are removed Cells can be used temporarily with one wire missing but replace the wire as soon as possible Replacement wires are supplied cut to length with eyelets on both ends for easy installat
55. r des d flecteurs Applications appareil de refroidissement Le filtre air devrait tre install en amont du serpentin de l vaporateur Le filtre air aidera garder le serpentin propre et permettra de r duire la fr quence de l entretien Applications humidificateur Un humidificateur vaporation peut tre install en amont du filtre air Un humidificateur atomiseur devrait tre install en aval du filtre air m me si des s diments d eau dure s introduiront dans les pi ces sous forme de poussi re et se d poseront Dans le cas d un humidificateur atomiseur en amont du filtre air 1 Monter l humidificateur le plus loin possible en amont du filtre air 2 Installer un filtre jetable standard pour appareil de chauf fage entre l humidificateur et le filtre air pour retenir les gouttes d eau et les s diments d eau dure 3 Nettoyer le filtre air fr quemment pour emp cher l accumulation de s diments d eau dure REMARQUE Le volume d eau qui passe dans l humidifica teur atomiseur peut surcharger le filtre air Par cons quent les s diments d eau dure pour raient s introduire dans les pi ces sous forme de poussi re FILTRE AIR LECTRONIQUE F300 Applications apport d air ext rieur La temp rature de l air repris doit tre d au moins 4 C 40 F Des temp ratures plus basses peuvent endommager les fils de l ionisateur L air ext rieur doit tre r chauff a
56. rifier les caract ristiques nominales indiqu es dans les instructions et sur le produit et s assurer que celui ci correspond bien l application pr vue 3 L installateur doit tre un technicien d exp rience ayant recu la formation pertinente 4 Une fois l installation termin e v rifier le fonctionnement du produit comme l indiquent les pr sentes instructions A AVERTISSEMENT Risque de choc lectrique Peut causer un choc lectrique ou endommager l quipement Ne pas brancher l appareil avant d avoir termin l installation D baller le filtre air lectronique S assurer qu il ne manque aucun composant Le filtre air lectronique est exp di assembl L appareil comprend un boitier en acier galvanis un bloc d alimentation avec un interrupteur et une lampe t moin deux cellules deux post filtres fibres deux pr filtres en mailles m talliques une porte d acc s et la documentation n cessaire Q Le W8600F en option les pi ces de montage et la notice d installation doivent tre command s s par ment Q Le W8600A en option les pi ces de montage les piles et la notice d installation doivent tre command s s par ment 68 0240EF 5 FILTRE A AIR ELECTRONIQUE F300 Nettoyer le compartiment du ventilateur Q Retirer et mettre de c t le filtre actuel de de chauffage Q Nettoyer fond le compartiment du ventilateur Si c est possible passer l aspira
57. rvice Offices in all principal cities of the world Manufacturing in Australia Canada Finland France Germany Japan Mexico Netherlands Spain Taiwan United Kingdom U S A 68 0240EF 5 2 F300 ELECTRONIC AIR AIR CLEANER EFFICIENCY AND PRESSURE DROP AT VARIOUS AIRFLOW RATES WITHOUT POST FILTERS CLEANER 1 25 16 x 20 in 62 2 406 x 508 mm 20 49 7 5 20 25 16 25 406 x 635 mm 508 x 635 mm 87 3 20 x 20 in x 20 x 12 1 2 in 508 x 508 mm T 508 x 318 mm 249 0 o A 05 x 12 4 A 3 0 400 500 600 700 800 900 1000 1100 1200 1300 1400 1500 1600 1700 1800 1900 2000 680 850 1020 1190 1360 1530 1700 1870 2040 2210 2380 2550 2720 2890 3060 3230 3400 CAPACITY m hr WITH POST FILTERS de 87 2 20 74 7 16 x 20 in 406 x 508 mm 25 20 x 12 1 2 in 62 2 508 x 318 mm 20 x 20 in 508 x 508 mm 20 x 25 in 2 508 x 635 mm 49 7 16 x 25 in 406 x 635 mm 15 z 37 3 8 c a 10 24 9 5 0 0 0 12 4 0 400 500 600 700 800 900 1000 1100 1200 1300 1400 1500 1600 1700 1800 1900 2000 680 850 1020 1190 1360 1530 1700 1870 2040 2210 2380 2550 2720 2890 3060 3230 3400 C
58. se original cover for color match Quantity required per unit N A Not available as merchandised part 17 68 0240EF 5 F300 ELECTRONIC AIR CLEANER e 2 N DY 7 ON NO 0 Y M 7 0 Fig 19 F300 Electronic Air Cleaner 2 cell model shown exploded view of components Part Numbers are keyed to Parts List 68 0240EF 5 18 F300 ELECTRONIC AIR CLEANER PARTS AND ACCESSORIES NOT ILLUSTRATED TABLE 5 Table 5 Parts and Accessories Not Illustrated Description Nominal Return Air Opening 16 x 20 in 406 x 508 mm 16 x 25 in 406 x 635 mm 20 x 12 1 2 in 508 x 318 20 x 20 in 508 x 508 mm 20 x 25 in 508 x 635 mm Air Cleaner Cabinet Gasket Kit 32002109 001 32002109 001 32002109 001 32002109 001 32002109 001 lonizer Wires Multiples of 5 136434BA 136434BA 136434AA 136434AA 136434AA Premier White AIRWATCH Indicator Premier White Air Cleaner Monitor W8600A1007 W8600F 1014 W8600A1007 W8600F1014 W8600A1007 W8600F1014 W8600A1007 W8600F1014 W8600A1007 W8600F1014 240V Conversion Kit 203365A 203365A N A 203365A 203365A Quantity required per unit N A Not available as merchandised part Obsolete available while supplies last 19 68 0240EF 5 F300 ELECTRONIC AIR CLEANER SERVICE REMIN
59. sse pas facilement dans le bo tier v rifier l orientation de la clavette de la cellule Q Ins rer le pr filtre en mailles m talliques du c t amont du bo tier dans le guide fourni Ins rer le post filtre fibres du c t aval du boitier dans le guide fourni Remettre la porte d acc s en place Ins rer la languette au bas de la porte dans la fente du bo tier refermer la porte en exer ant une pression La porte doit tre bien en place sinon le filtre air ne fonctionnera pas Terminer le raccordement AVERTISSEMENT Risque de choc lectrique Peut causer des blessures Ne pas utiliser de cordon de rallonge Tous les raccordements doivent tre conformes aux r glements et aux codes locaux ORANGE NINTERRUPTEUR D ASSERVISSEMENT Aner COURT CIRCUIT POUR LA REDUCTION D OZONE NCAVALIER POUR D SACTIVER INTERRUPTEUR DE DEBIT D AIR J8 CONNECTEUR DE L INTERRUPTEUR DE DEBIT D AIR 43 LA LAMPE AU N ON AA INDICATEUR W8600F EN OPTION W4 W2 W1 W3 COMMANDE DE D BIT D AIR L alimentation tension secteur doit correspondre la tension et la fr quence indiqu es sur l tiquette dans la porte d acc s Lorsque le ventilateur du syst me se met en marche l interrupteur d bit d air d tecte une pression n gative dans la gaine d air et met le filtre air sous tension Si l alimentation du filtre air est command e par un autre interrupteur l interrupteur
60. ssiste ou distributeur TRADELINE consultez le catalogue TRADELINE ou les tarifs pour obtenir le num ro de pi ce Pri re d adresser toute question additionnelle demande d information ou commentaires sur les produits et services par crit ou par t l phone 1 Au bureau des ventes de produits de r gulation et d automatisation Honeywell de votre localit consulter les pages blanches de l annuaire t l phonique 2 Honeywell Customer Care 1885 Douglas Drive North Minneapolis Minnesota 55422 4386 Au Canada Honeywell Limited Honeywell Limit e 35 Dynamic Drive Scarborough Ontario M1V 429 Points de vente et de service dans toutes les grandes villes du monde Usines en Allemagne en Australie au Canada en Espagne aux Etats Unis en Finlande en France au Japon au Mexique aux Pays Bas au Royaume Uni et Taiwan 68 0240EF 5 2 FILTRE AIR ELECTRONIQUE F300 EFFICACITE ET PERTE DE CHARGE DU FILTRE A AIR A DIVERS DEBITS D AIR SANS POST FILTRES 406 x 508 mm 16 x 20 in 406 x 635 mm 508 x 635 mm 20 x 25 in 16 x 25 in 508 x 508 mm 508 x 318 mm 20 x 20 in 20 12 1 2 in w A w PERTE DE PRESSION EN Pa PO D EAU 12 4 05 LAN A A 0 680 850 1020 1190 1360 1530 1700 1870 2040 2210 2380
61. te wash and rinse cycle Do not use the dry cycle To avoid burns let the cells cool completely before removing or wear protective gloves when removing the cells Remember that water may be trapped inside the cells Tip the cells so the tubes can drain 3 Wipe ionizer wires and contact board on the end of the cell using thumb and forefinger with a small damp cloth 4 Inspect the dishwasher Rerun wash and or rinse cycle with the dishwasher empty if there is dirt or residue from washing the cells If dirt or residue seems excessive wash cells more often or try a different detergent Washing Cells in a Container N CAUTION Hazardous Chemical Can cause personal injury Do not splash detergent solution in eyes Wear rubber gloves to avoid prolonged detergent contact with skin Keep detergent and solution out of reach of children NOTE Always wash the cells first then the prefilters to keep heavy prefilter lint from getting caught in the cells 1 Use a large enough container such as a laundry tub or trash container to hold one or both cells NOTE Sharp corners on cells can scratch surface of bathtub 2 Dissolve about 3 4 cup of automatic dishwasher deter gent per cell in enough hot water to cover the cells If detergent does not dissolve readily or forms a scum on the water try another brand or use softened water 3 After detergent has completely dissolved place cells in the container and let soak for 15 to 20 mi
62. teur dans le syst me de gaines pour liminer la poussi re accumul e dans une maison d j construite ou la salet due la construction dans une maison neuve Le filtre air lectronique ne peut liminer la poussi re accumul e dans le compartiment du ventilateur et les gaines de distribution Q V rifier s il n y a pas de la poussi re sur les bordures des lames du ventilateur de l appareil de chauffage Les nettoyer au besoin Le rendement du ventilateur sera inf rieur au rendement pr vu si les lames sont sales Fixer le bo tier l appareil de chauffage REMARQUE L installation d un filtre sur le c t d un appareil de chauffage caissons juxtapos s est d crite ci dessous Des modifications peuvent s av rer n cessaires dans le cas d un autre syst me Retirer et mettre de c t la porte d acc s les cellules les post filtres fibres et les pr filtres en mailles m talliques Q Aligner le boitier sur l ouverture pour la reprise d air Percer une ouverture dans l appareil de chauffage correspondant celle du boitier du filtre air Q Installer un raccord de transition si les ouvertures de l appareil de chauffage et du filtre sont de dimensions diff rentes Voir la Fig 4 Q Placer des blocs sous le boitier pour que l appareil soit bien soutenu et de niveau Le pied de fixation de 16 mm 5 8 po sur la plaque de la charni re du boitier assure le d gagement suffisant la charn
63. the amount may be higher because of sharp edges on some of the new high voltage metal parts Normal use quickly dulls these edges The average person can detect the odor of ozone in concentrations as low as 0 003 to 0 010 parts per million ppm The electronic air cleaner contributes 0 005 to 0 010 ppm of ozone to the indoor air The U S Food and Drug Administration and Health and Welfare Canada recommend that indoor ozone concentration should not exceed 0 050 ppm As a comparison the outdoor ozone level in major cities is sometimes as high 0 100 ppm However if desired the ozone generated by the air cleaner can be reduced in one of two ways 1 Install an activated carbon filter downstream from the air cleaner Make sure particles from the air filter cannot fall into the air cleaner F300 ELECTRONIC AIR CLEANER a Unplug or disconnect power supply to the air cleaner A WARN N G b Open the access door Remove the power box cover See Fig 17 Electric Shock Hazard d Locate J5 shorting bar on the power supply See Fig cause personal injury 18 Remove the shorting bar and reinstall on only Only a trained service technician should perform the one pin following procedure NOTE The ozone will be reduced but the shorting bar is 2 Move J5 shorting bar This will reduce ozone production ilable 8 installation if ded about 20 to 25 percent and reduce efficiency about seven to ten percent depending o
64. tion par multiples de 5 136434BA 136434BA 136434BA 136434BA Vis de fixation 136375 6 136375 6 136375 6 136375 6 Moniteur de filtre a air beige W8600F 1008 W8600F 1008 W8600F 1008 W8600F 1008 Indicateur AIRWATCHMP blanc Premier W8600F 1007 W8600F 1007 W8600F 1007 W8600F 1007 White Moniteur de filtre a air blanc Premier W8600F 1014 W8600F 1014 W8600F 1014 W8600F 1014 White Cellule de filtre a air lectronique a deux S O FXC37A1247 2 5 0 FC37A1239 2 tages avec pour collecteur Trousse de conversion a 240 V 60 Hz 203365A 203365A 203365A 203365A Nombre quantit requise par appareil S O ces pi ces ne sont pas vendues s par ment 19 68 0240EF 5 FILTRE A AIR ELECTRONIQUE F300 CALENDRIER DE RAPPEL DU LAVAGE CALENDRIER DE RAPPEL DU LAVAGE DES CELLULES DU FILTRE A AIR DATE D INSTALLATION ANNEE J F M 5 0 N 19779 68 0240EF 5 20 FILTRE AIR ELECTRONIQUE F300 COMMENT UTILISER CE TABLEAU GUIDE DE VERIFICATION DEPANNAGE DU FILTRE A AIR 1 SUIVRE LES TAPES DANS L ORDRE INDIQUE DEPART 2 NE PAS SAUTER D ETAPE Ce 3 DES QU UN PROBLEME EST REGLE REVENIR LA CASE DEPART REPETER TOUTES LES TAPES JUSQU CE QUE LE FILTRE A AIR FONCTIONNE COMME PREVU REMARQUE SI UN INDICATEUR W8600F EST RACCORDE AU FILTRE AIR D BRANCHER LE FILTRE AIR DU W8600F AVANT DE PROC DER LA V RIFICATION LE W8600F
65. tions with Outdoor Air Intake Return air temperature must be at least 40 F 4 C Lower temperatures can cause ionizer wire failure If outdoor air is used warm it upstream from the air cleaner by Making sure the outdoor intake is far enough upstream from the air cleaner so the return and outdoor air is thoroughly mixed Stratified air can dump a stream of very cold air into one section of the air cleaner Adding baffles upstream from the air cleaner to force thorough air mixing Installing a Honeywell Perfect Window Fresh Air Ventilation System that transfers up to 80 percent of the heat from the exhaust air to the incoming outside air This keeps the incoming air above 40 F 4 and reduces energy usage Installing a preheater if large amounts of outdoor air are used The preheater which could be an electric strip heater or hot water coil should be controlled by a thermostat Hot water or steam coils should be protected by a freeze up control Optional W8600F Air Cleaner Monitor The W8600F Air Cleaner Monitor can be mounted in the living area or in the furnace room It should be located in a convenient location to observe the display The W8600F Air Cleaner Monitor is furnished with all the connectors needed for easy installation Follow the installation instructions provided with the W8600F Optional W8600A AIRWATCH Indicator The W8600A can be mounted next to the thermostat or in any other location in the
66. twork to air cleaner Note turning vanes Locking pliers hold duct to air cleaner cabinet during installation Seal Joints Seal all joints in the return air system between the air cleaner and the furnace to prevent dust from entering the clean airstream Use optional air cleaner cabinet gasket kit part no 32002109 001 mastic or foil tape Position Cell Key The electronic cell must always be installed so the ionizer section is on the upstream side A factory installed cell key on the bottom of the cabinet allows the cell to be inserted in only one direction If the arrow molded into the plastic key points in the same direction as the airflow the ionizer is always on the upstream side If position of the key must be reversed proceed as follows 1 Remove the electronic cell 2 Remove the screw holding the cell key in place See Fig 8 F300 ELECTRONIC AIR CLEANER DOWNSTREAM C CELL KEY PREFILTER GUIDES ALTERNATE HOLES FOR M5639 Fig 8 Position of cell key determines orientation of cell arrow on key must point downstream 3 Turn the key around and place it over the opposite holes The tab on the bottom fits into the larger hole and the screw fits into the smaller hole Make sure the arrow on the key points in the direction of the air flow down stream 4 Tighten the screw into the new hole 5 Insert the electronic cell The ionizer section will now be on the air enter
67. ue la fl che de d bit d air pointe vers l aval et que les poign es soient vers l ext rieur 4 Fermer soigneusement la porte d acc s 5 Mettre en marche le filtre air Si les cellules ou les pr filtres sont toujours mouill s la lampe t moin pourrait s allumer pourrait y avoir des arcs Si le bruit est agagant simplement arr ter le filtre air pendant 2 3 heures ou jusqu ce que les cellules soient s ches Remplacement des post filtres fibres Afin de maximiser l efficacit de filtration des post filtres fibres il faut les remplacer tous les six mois Les post filtres de rechange sont offerts dans les m mes tailles et configurations que ceux fournis avec l appareil Communiquer avec un distributeur de produits Honeywell pour obtenir des post filtres de rechange Il faut les installer de la m me fa on que ceux fournis avec l appareil Utiliser le calendrier de rappel la fin du pr sent document pour tablir les dates de remplacement des post filtres Placer le calendrier un endroit pratique Remplacement des fils d ionisation Des fils d ionisation pli s ou cass s peuvent provoquer un court circuit ou une fuite la terre ce qui provoque souvent un arc visible ou des tincelles Ne pas utiliser les cellules tant que les fils d ionisation n ont pas t r par s ou remplac s Les cellules peuvent tre utilis es s il manque un fil mais il faudrait voir remplacer ce fil le plus rapidement
68. vant qu il n atteigne le filtre air Il faut donc S assurer que l apport d air ext rieur est suffisamment en amont du filtre air pour que l air repris et l air ext rieur soient parfaitement m lang s Si l air est stratifi un jet d air tr s froid pourrait circuler dans une section du filtre air Ajouter des d flecteurs en amont du filtre air pour assurer le m lange complet de l air Installer un syst me de ventilation d air frais Perfect Windows de Honeywell pour la maison qui servirait transf rer 80 de la chaleur de la gaine de soufflage l air frais provenant de l ext rieur L air ext rieur serait ainsi r chauff plus de 4 40 F ce qui r duirait la consommation d nergie Installer un appareil de pr chauffage si l apport d air ext rieur est important Cet appareil par exemple un l ment chauffant ou un serpentin d eau chaude devrait tre command par un thermostat Les serpentins d eau chaude ou vapeur devraient tre prot g s par un dispositif antigel Ajout du moniteur W8600F en option Le moniteur de filtre air W8600F peut tre mont dans une pi ce ou dans la salle o est situ l appareil de chauffage Il doit tre install un endroit permettant de bien voir les voyants Le moniteur de filtre air W8600F comprend tous les raccordements n cessaires installation facile Suivre les directives d installation comprises avec le W8600F Ajout d
69. x 635 mm 508 x 318 mm 508x 508 mm 508 x 635 mm Item Ib kg Ib kg Ib kg Ib kg Ib kg Electronic Cell 5 2 25 6 2 7 7 1 2 3 4 6 3 16 2 8 7 1 2 3 4 each Shipping Weight 30 13 6 33 15 0 25 11 3 33 15 0 38 17 2 Installed Weight 26 11 6 28 12 7 21 9 5 29 13 2 33 15 0 Cells included 68 0240EF 5 6 3 8 462 F300 ELECTRONIC AIR CLEANER Honeywell 5 ELECTRONIC AIR CLEANER DIM E SEE TABLE DIM B ISEE TABLES SEE TABLE 8 3 SEE TABLE sn n t s sPp 22 172 16 DIM D SEE TABLE gt EEE ma DME mm LN Ju ww 6 521 20 121 2 508x318 18716 468 2036 513 1078 276 1318 333 358 48 521 333 2872 Fig 2 Electronic air cleaner installation dimensions in in mm PLANNING THE INSTALLATION Application The F300 Electronic Air Cleaner is used in a forced air heating cooling or ventilating system It removes airborne particles from the air circulated through it All models have an internal air flow switch that automatically energizes the air cleaner cells when the system blower is on Review Installation Requirements The air cleaner should be installed where all the air passing through the system circulates through it The best location is in the return air duct next to the
70. xperienced service technician 4 After installation is complete check out product operation as provided in these instructions A WARNING Electric Shock Hazard Can cause electrical shock or equipment damage Do not connect to power before installation is complete Unpack Electronic Air Cleaner Q Check that all components are included The electronic air cleaner is shipped assembled The unit consists of a galvanized steel cabinet power supply with On Off switch and neon light two electronic cells two metal mesh prefilters two media postfilters on select models access door and product data literature Q Order W8600F optional including mounting hardware and installation literature separately Q Order W8600A optional including mounting hardware batteries and literature separately 68 0240EF 5 8 Clean Blower Compartment Remove and discard the existing furnace filter Thoroughly clean the blower compartment Q If possible power vacuum the ductwork to remove accumulated dust in an existing home or construction dirt in a new home The electronic air cleaner cannot remove dust that has settled in the blower compartment and distribution ducts Q Check the edges of the furnace fan blades for dirt buildup and clean as necessary The fan will not deliver the rated cfm if the blades are dirty Fasten Cabinet To Furnace NOTE This procedure shows a side installation on a typical highboy furnace You
71. y Limit expansion to no more than 20 degrees or about 4 in per running foot 100 mm per 300 linear mm on each side of a transition fitting See Fig 4 CHANGE DUCT SIZE GRADUALLY TO MINIMIZE TURBULENCE 20 DEGREE EXPANSION PER SIDE PER FITTING 4 in PER LINEAR FOOT RETURN AIR DUCT TRANSITION FITTING ELECTRONIC AIR CLEANER CABINET t M5626A Fig 4 Change duct size gradually to minimize turbulence Turning Vanes If the air cleaner is installed close to an elbow or angle fitting install turning vanes inside the angle to distribute airflow more evenly across the face of the cell See Fig 5 68 0240EF 5 F300 ELECTRONIC AIR CLEANER Offsets If the duct connection to the furnace in a side installation allows less than 7 in 178 mm for mounting the air cleaner cabinet add an offset to the elbow See Fig 5 TYPICAL USE OF DUCT OFFSET TO ALLOW SPACE FOR ELECTRONIC AIR CLEANER OFFSET LESS THAN 178 mm 178 VANES HELP DISTRIBUTE AIRFLOW EVENLY M5627A Fig 5 Typical use of duct offset to allow space for electronic air cleaner INSTALLATION When Installing this Product 1 Read these instructions carefully Failure to follow them could damage the product or cause a hazardous condition 2 Check the ratings given in the instructions and on the product to make sure the product is suitable for your application 3 Installer must be a trained e
Download Pdf Manuals
Related Search
Related Contents
環境報告書2006 - ACCRETECH Description produit et fonction MagPro Bill Acceptor Operation and Service Manual Kensington SlimBlade™ Trackball ウェルライフパートナーズ 【事業案内】 USBネックウォーマー 取扱説明書 Oracle Database Application Express User's Guide manual de usuario - Powerplanetonline 540 Cruiser 2005 - Watersport Vonk Valueline VLCP74200V015 power cable Copyright © All rights reserved.