1. DIRECTLY OR INDIRECTLY FROM ANY BREACH OF ANY WARRANTY EXPRESS OR IMPLIED OR ANY OTHER FAILURE OF THIS PRODUCT Some states do not allow the exclusion or limitation of incidental or consequential damages so this limitation may not apply to you THIS WARRANTY IS THE ONLY EXPRESS WARRANTY HONEYWELL MAKES ON THIS PRODUCT THE DURATION OF ANY IMPLIED WARRANTIES INCLUDING THE WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PUR POSE IS HEREBY LIMITED TO THE ONE YEAR DURATION OF THIS WARRANTY Some states do not allow limitations on how long an implied warranty lasts so the above limitation may not apply to you This warranty gives you specific legal rights and you may have other rights which vary from state to state If you have any questions concerning this warranty please write Honeywell Customer Relations 1985 Douglas Dr Golden Valley MN 55422 or call 1 800 468 1502 In Can ada write Retail Products ON15 02H Honeywell Limited Honeywell Limit e 35 Dynamic Drive Scarborough Ontario M1V4Z9 75 Customer Assistance If you have any questions about the operation of your thermostat please go to http yourhome honeywell com or call Honeywell Customer Care toll free at 1 800 468 1502 p J As an ENERGY star partner Honeywell has PPTK determined that this product meets the ENERGY STAR IESIT guidelines for energy efficiency 69 2023 1 11 06 2 2
2. the thermostat will automati cally exit the programming mode 08161 TH110 DP P TL8230 Programmable Thermostat Installation and User Guide Troubleshooting Problems Solutions The thermostat s screen is blank The thermostat s switch is set to Off The measured temperature is below the LO is displayed display range Heating is activated The measured temperature is above the HI is displayed display range The thermostat was without power for The wrong time is displayed mor than 2 hours The thermostat is located in a spot The measured temperature is wrong exposed to an air draft The heater is always On Check the thermostat wiring The thermostat indicates that heating is On but the heater is not On Check the thermostat wiring Check that the thermostat is in Automatic mode Check also the energy saving schedule and clock settings The temperature does not change accord ing to the energy saving schedule Technical Specifications Power 208 240 Vac 60 Hz Maximum load 16 A maximum resistive only 3328 watts 208 Vac 3840 watts 240 Vac Display range 32 F to 140 F 0 C to 60 C Display resolution 0 1 F 0 1 C Setpoint range 40 F to 86 F 5 C to 30 C Setpoint interval 1 F 1 C Storage 4 F to 120 F 20 C to 50 C Certifications CSA UL Data backup In the event of a power outage most settings are s
3. such as the top of a staircase or an air outlet dead air spots such as behind a door or direct sun light Do not install the thermostat on a wall that conceals chimney or stove pipes Connect the thermostat wires to the Black power and to the load using solderless Load Power connectors for copper wires Push the excess wire back into the electrical box to prevent interference with the thermostat Secure the thermostat using two 6 32 screws Return power to heating system NOTE Always keep the thermostat s vents clean and unobstructed Load 08161 TH110 DP P TL8230 Programmable Thermostat Installation and User Guide 08161 TH110 DP P TL8230 Configuration The configuration switches are on the back of the thermostat Default factory settings are inside the gray cells Configurations UP DN sw Not used Sw2 Early Start Disable Enable SW3 Time format 12 hour 24 hour sw4 Temperature format gt F C a Early Start can be used in Automatic mode only When this function is enabled the thermostat calculates the optimal time to start heating in order to obtain the desired temperature by the set time The thermostat re assesses the start time daily based on the previous day s perfor mance b If you change the temperature display format the preset temperatures 4 Cand will return to their def
4. Honeywell Description This programmable thermostat can be connected to an electric heating sys tem such as an electric baseboard a radiant ceiling a floor heating system an electric convector etc It is not compatible with a central heating system Time and day Appears during the On Off pA 3 pA setpoint display switch WILI 7 MOTUWETHER Temperature Operating Off gt li H F mode icons Preset temperature Oa LIL icons Opt Heating a indicator 499 bey To set the day EDES tee Ss Periods fry TA fetal wp To set the time To program the schedule i K Pan Temperature yt CO q preset buttons Cear To skip a period To select the ee operating mode adjustmen PN v ip z Set the switch to Off to cut power to the heater This will not affect the time and tem perature settings Connection TURN OFF POWER TO THE HEATING SYSTEM AT THE MAIN POWER PANEL TO AVOID ELECTRICAL SHOCK The installation must be carried out by an electrician All cables and connections must conform to the local electrical code Special CO ALR solderless connectors must be used when connecting with aluminum conductors Install the thermostat onto an electrical box Install the thermostat about 5 feet high on an inside wall facing the heater Avoid locations where there are air drafts
5. ault settings Power up Upon power up the thermostat is in manual mode 4 and displays the actual temperature Press the Hour and Min buttons to set the thermostat s clock Press the Day button to set the day Temperature Setting Setpoint The thermostat normally displays the actual temperature To view the set point press the a or w button briefly The setpoint will appear for the next 5 seconds To change the setpoint press the a or w button until the desired temperature is displayed To scroll faster hold the button Using a preset temperature The thermostat has 3 preset temperatures gt Comfort temperature x gt Economy temperature q gt Vacation temperature cp Icon Intended use Default setting 70 F 21 C 62 F 16 C 50 F 10 C x Comfort when at home q Economy when asleep or away from home Vacation during prolonged absence To use the Comfort or Economy temperature press the X or button respectively The corresponding icon will be displayed To use the Vacation temperature press both lt and buttons simulta neously The icon will be displayed Storing a preset temperature To store the Comfort or Economy temperature Set the desired temperature using the a or w button Press and hold the appropriate button 4 or for approximately 3 seconds until the corresponding icon is displayed To store th
6. aved Only the time must be re adjusted if the power outage lasts more than 2 hours The thermo stat will return to the mode that was active prior to the power outage V Warranty Honeywell warrants this product excluding battery to be free from defects in the work manship or materials under normal use and service for a period of one 1 year from the date of purchase by the consumer If at any time during the warranty period the product is determined to be defective or malfunctions Honeywell shall repair or replace it at Hon eywell s option If the product is defective i return it with a bill of sale or other dated proof of purchase to the place from which you purchased it or ii call Honeywell Customer Care at 1 800 468 1502 Customer Care will make the determination whether the product should be returned to the following address Honeywell Return Goods Dock 4 MN10 3860 1885 Douglas Dr N Golden Valley MN 55422 or whether a replacement product can be sent to you This warranty does not cover removal or reinstallation costs This warranty shall not apply if it is shown by Honeywell that the defect or malfunction was caused by damage which occurred while the product was in the possession of a consumer Honeywell s sole responsibility shall be to repair or replace the product within the terms stated above HONEYWELL SHALL NOT BE LIABLE FOR ANY LOSS OR DAMAGE OF ANY KIND INCLUDING ANY INCIDENTAL OR CONSEQUENTIAL DAMAGES RESULTING
7. e Vacation temperature Set the desired temperature using the a or w button Press and hold both X and buttons simultaneously for approximately 3 seconds until the icon is displayed Press the Mode button 69 2023 1 11 06 1 2 Operating Modes Automatic The temperature is set according to the energy saving schedule To place the thermostat in this mode press Mode until is dis played The icons of the current period and preset temperature are also dis played Temporary Bypass If you modify the setpoint by pressing the a V X or button when the thermostat is in automatic mode the new set point will be used until the end of the current period When the next period starts the temperature set for that period becomes the new set point rf Manual The energy saving schedule is not used The temperature must be set manually To place the thermostat in this mode Press Mode until 4 is displayed set the temperature using the a w lt lt or button Vacation The thermostat is set to the Vacation temperature Press both X and buttons simultaneously to place the thermostat in Vacation mode Energy saving Schedule The schedule consists of 4 periods per day which represents a typical week day You can program the thermostat to skip the periods that do not apply to your situation For example you can skip periods 2 and 3 for the weekend Period Description Associated p
8. reset temperature fi Wake up x N4 Away from home q Nea Return home w T Sleep q The Comfort lt temperature is used in periods 1 and 3 and the Economy temperature is used in periods 2 and 4 For example when the period changes from 1 to 2 the setpoint automatically changes from Comfort setting to Economy setting 0 You can have a different program for each day of the week i e each period can start at different time for each day of the week The thermostat has been programmed with the following schedule Period Setting MO TU WE TH FR SA SU p m 6 00 6 00 6 00 6 00 6 00 6 00 6 00 i AM AM AM AM AM AM AM 8 00 8 00 8 00 8 00 8 00 Pas AM AM AM AM AM 7 77 7 6 00 6 00 6 00 6 00 6 00 Maj Ke PM PM PM PM PM 7 OTT 10 00 10 00 10 00 10 00 10 00 10 00 10 00 rr PM PM PM PM PM PM PM To modify the schedule Press Pgm to access the programming mode Period 1 is selected Press Day to select the day to program hold for 3 seconds to select the entire week Press Hour and Min to set the start time of the selected period or press Clear if you want to skip the period is displayed Press Pgm to select another period or press Day to select another day Then repeat step 3 00 Press Mode to exit the programming mode NOTE If no button is pressed for 60 seconds
Download Pdf Manuals
Related Search
Related Contents
Braun Photo Technik VidiProof Audi A3 Sportback Audi A3 Sedan Audi S3 Sedan Audi S3 Sportback Notes d`architecture rurale : Les fermes anciennes dans le Mantois Mode d`emploi - Nord Keyboards TP-Link TL-MR3020 Data Sheet 取扱説明書 DOC. NO. 5958 793 00 - mbm Polk Audio FXiA6 Owner's Manual Copyright © All rights reserved.