Heart & Home Collectables GFK-210 User's Manual

image

Contents

1. and the temperature sensor switch to the power cord See Figure 6 4 Gather the loose wires underneath the appliance and use the zip ties to restrain them and keep them away from the blower wheel fan blades See Figure 6 Detail A 5 Turn the 110 120 VAC service ON at the circuit breaker DETAIL A COMBUSTION BOX SURFACE 8 g BLOWER STUD TEMPERATURE SENSOR SWITCH Figure 5 6 0 RECOMMENDED OPERATING PROCE DURES WHEN VARIABLE SPEED CONTROL AND TEMPERATURE SENSOR SWITCH ARE USED Ignite the fire in the fireplace with the variable speed control switch in an ON position The fan will automatically turn on when the temperature sensor switch closes at approxi mately 110 F Heated air will be delivered at the outlet grille The fan will continue to operate after the fireplace is turned OFF until the temperature sensor switch opens NOTICE During operation ensure that all wiring is kept away from the blower wheel fan blades Various conditions such as fireplace model type of fire place installation outside air temperature vs inside air temperature can contribute to the length of the time the blower remains on after the fireplace is turned OFF The blower can be turned off manually with the speed control Switch WARNING Risk of Injury DO NOT contact the blower wheel fan blades during operation 7 0 MAINTENANCE Periodi
2. GFK 210 Blower System HEARTHG HOME technologies Installation and Operating Instructions 1 0 INTRODUCTION The GFK 210 Blower System has been designed to circu late room air through the fireplace to enhance heat output The GFK 210 blower system operates on 120 VAC 60 Hz power This is available through a receptacle in the factory installed power cord assembly The power cord is located in the controls compartment of the fireplace Avariable speed control is provided with the blower system to provide quiet forced air flow at the desired speeds A temperature sensor switch which automatically turns the blower ON OFF is also provided with this kit NOTICE The variable speed control and temperature sensor switch are not used with some remote control systems 2 0 CHECK CONTENTS OF SHIPPING CARTON Compare CONTENTS OF CARTON in Figure 1 with the actual parts received If any parts are missing or damaged contact your dealer before starting installation Do not install a damaged blower kit TEMPERATURE SENSOR NA LL CONTROL SWITCH KNOB 046 018A 100 512 CONTROL N UT 060 814 VARIABLE SPEED CONTROL 2206 800 Figure 1 3 0 INSTALLATION PRECAUTIONS The GFK 210 Blower Kit is tested and safe when installed in accordance with this installation manual It is your responsi bility to read all instructions before starting installation and to follow these instructions carefully during installati
3. L WIRE AS SUPPLIED WITH THE APPLIANCE MUST BE REPLACED IT MUST BE REPLACED WITH TYPE 105 C RATED WIRE NOTE USE ZIP TIES TO RESTRAIN THE LOOSE WIRES UNDERNEATH THE APPLIANCE AND KEEP THEM AWAY FROM THE BLOWER WHEEL FAN BLADES NOTE SENSOR SWITCH AND RHEOSTAT SPEED CONTROL MUST BE REMOVED FROM CIRCUIT IF SYSTEM IS CONTROLLED WITH RC200 300 REMOTE PLUG INTO 120V EXISTING OUTLET DC REGULATOR RECEPTICLE AUX 300 MODULE TO CONTROL MODULE BLOWER RECEPTICLE Figure 7 Fan Wiring Diagram Metal Insert with RC200 RC300 Remote Plug two cord assembly spade connectors together Unplug fan cord assembly from standard cord assembly Install fuse wire assembly in series between the black lead wires of the fan cord and black lead wire on each blower See Figure 7 5 Plug fan cord assembly into AUX300 module 6 Plug AUX300 module into the standard cord assembly oo FUSE WIRE ASSEMBLY FUSE WIRE ASSEMBLY 90 Hearth amp Home Technologies GFK 210 Blower System Instructions 2206 938 Rev H 7 11 5 10 0 INSTALLING THE BLOWER FireBrick Inserts 1 2 Remove appliance from wall Disconnect power by shutting off circuit breaker or unplugging appliance power cord from its receptacle Remove access panel from lower rear of the fireplace insert See Figure 8 Attach blower to base with two screws See Figure 9 Connect white and green wires from blower wir
4. TE Install the blower using the access panel located on the back side of the appliance Figure 2 Remove Blower Brackets Hearth amp Home Technologies GFK 210 Blower System Instructions 2206 938 Rev H 7 11 1 Figure 4 Attach Blowers to Access Cover 2 Hearth amp Home Technologies GFK 210 Blower System Instructions 2206 938 Rev H 7 11 5 0 INSTALLING THE VARIABLE SPEED CONTROL AND TEMPERATURE SENSOR SWITCH If using a remote control system that utilizes a blower fan control disregard steps 1 3 and follow remote con trol installation instructions NOTICE The sensor switch and rheostat are not used if the blower is controlled with the RC300 remote control 1 Remove the knob and locknut from the variable speed control Slide the variable speed control behind the control panel With the stem sticking out of the pre punched hole attach the locknut tightly and reattach the knob on the stem See Figure 4 Turn the speed control switch to the ON position 2 Slide the temperature sensor switch onto the blower stud located on the bottom of the combustion box See Figure 3 Secure the temperature sensor switch with the wing nut provided NOTICE The blower stud is located on the bottom of the combustion box See Figure 5 NOTICE The temperature sensor switch must be installed so that the sensor switch is facing the combustion box surface See Detail A of Figure 5 3 Connect the variable speed control
5. cally check the fireplace and remove any dust dirt or obstructions 8 0 REPLACEMENT PARTS AND CUSTOMER SERVICE Replacement parts and service may be obtained through your dealer Hardware Bag SRV107 570A VARIABLE SPEED TEMPERATURE CONTROL SENSOR SWITCH BLOWER STUD Hearth amp Home Technologies GFK 210 Blower System Instructions 2206 938 Rev H 7 11 3 NOTE IF ANY OF THE ORIGINAL WIRE AS SUPPLIED WITH THE APPLIANCE MUST BE REPLACED IT MUST BE REPLACED WITH TYPE 105 C RATED WIRE PLUG INTO 120V EXISTING OUTLET DC REGULATOR VARIABLE SPEED RECEPTACLE CONTROL BLOWER s tuno TEMPERATURE BLOWER SENSOR SWITCH RECEPTACLE PLUG 120V EXISTING OUTLET CONTROL CONTROL RHEOSTAT Figure 6 Fan Wiring Diagram Metal Insert Without RC200 RC300 4 Hearth amp Home Technologies GFK 210 Blower System Instructions 2206 938 Rev H 7 11 9 0 Fan Wiring with Remote This appliance may be used with an RC200 or RC300 remote control See Figure 7 1 Remove cord assembly spades from rheostat and sensor switch NOTICE Fan speed and operation are controlled by the remote control The sensor switch and rheostat are no longer needed NOTE IF ANY OF THE ORIGINA
6. e assembly to each blower See Figure 9 Connect the fuse wire assembly in series between black wires of blower wire assembly and each blower See Figure 10 Insert plug from blower cable assembly into AUX300 receptacle See Figure 10 Bundle and zip tie loose wires to keep them from con tacting blower impeller blades Position the right and left blower assembly into the rear opening Take care to ensure that blower housing or its motor is clear of any adjacent metal This will ensure that no undue noise occurs during blower operation Reinstall access panel Reconnect power to the insert and install into wall BLOWER ACCESS PANEL POWER CORD Figure 8 Remove Access Panel Figure 9 Attach Blower to Base Hearth amp Home Technologies GFK 210 Blower System Instructions 2206 938 Rev H 7 11 Note if any of the original wire as supplied with the appliance must be replaced it must be replaced with type 105 C rated wire BLOWERS Note use zip ties to restrain the loose wires underneath the appliance and keep them away from the blower wheel fan blades PLUG INTO 120V EXISTING OUTLET DC REGULATOR RECEPTACLE BLOWER RECEPTACLE Figure 10 Fan Wiring Diagram FireBrick Inserts Please contact your Hearth amp Home Technologies dealer with any questions or concerns For the location o
7. f your nearest Hearth amp Home Technologies dealer please visit www fireside com PLUG TO c EXISTING OUTLET D 1 1 GROUND TO VALVE BRACKET GREEN TO VALVE ORANGE TO VALVE Da FUSE WIRE ASSEMBLY BLOWERS FUSE WIRE ASSEMBLY Shoo Hearth amp Home Technologies Inc 7571 215th Street West Lakeville MN 55044 www fireside com Hearth amp Home Technologies GFK 210 Blower System Instructions 2206 938 Rev H 7 11
8. on to assure maximum benefit from and safe operation of the blower This blower is carefully engineered and must be installed only as specified If you modify it or any of its components you may cause a fire hazard and will void the WARRANTY In addition such action may void the coverage provided by the owner s home insurance CAUTION All wiring should be done by a qualified electri cian and shall be in compliance with local codes and with the National Electric Code ANSI NFPA NO 70 current in the United States or with the current CSA C22 1 Canadian Electric Code in Canada CAUTION DO NOT connect 110 120 VAC wiring to the gas control valve of the fireplace WARNING Risk of Shock Turn electrical power off at the circuit breaker before beginning this installation 4 0 INSTALLING THE BLOWER Metal Inserts 1 Remove factory installed blower brackets by removing four screws Brackets are only used for the FireBrick inserts See Figure 2 2 Remove appliance from wall 3 Remove access panel by removing four screws See Figure 3 4 Screw blowers to access panel on rear of insert with four screws See Figure 4 5 Plug the blower cord into the blower receptacle Con nect the white black and green spade connectors from blower cord harness to each blower See Figure 1 and Figure 6 6 Bundle and zip tie any wires to keep them from contact ing the fan blades See Figure 6 Detail A 7 Reinstall access panel NO