1. The unit should be directed away from heat sources such as radiators heating ducts and stoves gt If the unit goes off at random it is possibly located too close to a heat source Changing the location or direction of the unit can remedy this n If the unit messes up during the programming procedure becomes abnormal or if you forget the PASSWORD take out the battery and wait for about 3 minutes for unit to reset replace the battery The system will reset to the initial normal stat for you to re program The unit can provide valuable protection your home and property if utilized properly However this unit cannot guarantee complete protection against burglary or robbery therefore we will not be held responsible for any loss or damages which could occur 1 COMPONENT LIST Quantity 1 Main Unit 1 pe 2 Transmitter remote 1 pe 3 Magnetic Sensor 2 sets 4 Double Side Tape for Magnetic sensor 4 pcs 5 Small Screws 8 pcs optional for fixng magnet sensor permanently 6 Screw and Anchor 5 Pcs each for wall mount motion sensor and siren 7 Adaptor 1 SYSTEM CONFIGURATION gt 22 Optional we NSTALLATION 1 Remove the Screw of main unit from battery compart ment cover slide it down to remove the cover Fig 1 Fig 2 Fig 1 2 Install an alkaline battery This is a backup battery In case of AC power failure this battery
2. on Remote Unit to stop the alarm TO TEST THE DETECTION AREA After selecting a location for installation of the unit you can turn the chime on and wait for 60 seconds for WARM UP Then you try walking in front of the unit When the unit detects motion the chime will sound There will be no chime sound if you walk beyond the detection range By testing the detection range can adjust the location the sensor angle for best coverage Tum the chime off after you test BATTERY LOW INDICATOR When 9 battery goes low the LED will flash once every 3 seconds to indicate the low battery in arm mode Change a new alkaline 9V battery immediately or else the sensor might not detection properly INTRUSION MEMORY INDICATOR When you disarm the unit if the LED flashes 3 times it indicates that there has been intrusion during the last arming mode Be sure to check your home office thoroughly after entering TROUBLE SHOOTING GUIDE A UNIT WILL NOT ARMED DISARM e Make sure you ve entered the correct security code If not re enter the correct code If still doesn t work Remove the 9V battery and adaptor plug wait for about 3 minutes replace them again Then try amp DISARM again B Magnetic sensor false Alarm make sure wire connec tion is correct and according to Installation 4 C
3. 42768 Bie ec ae aT a Sete Uae se eee ee A Fe MS oe Sh er ae BE Sige Se SB Ee eee MOTION DETECTOR ALARM WITH REMOTE CONTROLER MAGNETIC SWITCH 135PLUS OPERATION INSTRUCTIONS INTRODUCTION HomeSafe s unique passive infrared technology and magnetic sensor integrated this basic security system in providing a central control of monitoring multi entrance and door window environment The main unit controls the system disarm and programming setting functions Transmitter remote can set main unit for arm or disarm mode and trigger alarm immediately The magnetic sensor switches link the door windows to enhance the protected areas Motion sensor detects motion amp activates aiarm e Expandable detection unit and magnetic sensor to enable wide area protection Programmable security code and entry delay timing Transmitter remote contro Arm Disarm or panic mode Built in high output 105dB atarm Alarm door chime option Panic button Program amp low battery indicator Verification tone for key pad and anm disarm AC adaptor included and 9V battery for power backup battery not included IMPORTANT SAFETY TIPS Do not install alarm where it will be exposed to direct sunlight or rain The alarm siren is very loud never put the unit close to your ear
4. emote control operation occurs replace the batteries according to BATTERIES REPLACE MENT The battery life should be about six months under normal use si replace battery at least every 6 months Effective range 19 12 Fig 12 _ PROGRAMMING SETTING NOTE The Security code is initially factory set at 0 0 0 when you first put in the battery You can program your own security up to 6 digits If more than 6 digits are entered you will hear an error tone 1 To program new security code after battery installation A Press the digits 0 0 0 B Press the PROG button C Enter you new code number 1 6 digits D Press the PROG button again 5 2 To change existing code to a new code A Enter the old code number Press the PROG button C Enter your new code number 1 6 digits D Press the PROG button again 3 To program the alarm timing A Press PROG button B Press one of number 1 2 or 3 for different timing 1 30 seconds alarm 2 cycles 30 seconds rest in between Preset timing 2 60 seconds alarm 2 cycles 30 seconds rest in between 3 90 seconds alarm 2 cycles 60 seconds rest in between 4 To program the entry delay timing A Press PROG button B Press one of number 7 8 or 9 for different timing 7 20 seconds delay Preset timing 8 10 seco
5. nds delay 9 0 seconds delay Instant alarm REMARKS e The programming can only be operated during disarm mode When unit is in arm mode no programming is allowed for added protection OPERATION 1 TO ARM THE UNIT A Enter your security code or 0 0 0 if you did not change the code B Press ARM you will hear 3 short beeps to confirm ARMED C You can press ARM button on Remote unit to ARM Main Unit as well NOTE e Make sure to switch off the chime switch before arming There will be beep after 60 seconds sensor warm up and exit delay after arming the unit The system is ready to detection after that BEEP 2 TO DISARM THE UNIT A Enter your security code B Press DISARM you will hear one beep to confirm disarming C You can Press DISARM button on Remote Unit to DISARM Main Unit as well 3 DOOR CHIME ON OFF A Slide the chime switch to ON B Wait for 60 seconds after a beep for the sensor to WARM UP Then when human movement is detected it will sound DING DONG chime 6 Slide the switch to OFF to tum the chime function off NOTE When unit is in arm mode the chime will not function 4 PANIC BUTTON A Press PANIC button on main unit or remote con trol to trigger alarm immediately for 30 seconds B To stop the alarm just enter your security code and press DISARM C Or press DISARM button
6. to the wall by using the two screws and anchors include _ 7 To plug in AC adaptor Plug the AC adaptor to the adaptor jack located on the side of the unit Fig 8 Plug in the AC adaptor to an AC outlet The AC adaptor output 9 volt 500mA with 3 5mm diameter male plug center positive The AC power LED indicator will be on constantly to indicate that an AC adaptor is in use Fig 8 8 Mount the magnet sensor to the door window door window frame by using the double side tapes and aligned the 2 sensor pieces to be flushed and arrow facing arrow at no more than 1 4 inch apart Fig 9 arrow facing arrow Fig 9 9 To mount the outdoor siren optional not included Use the siren stand as a template mark locations of holes and install anchors and screws as shown in Fig 10 Fig 10 4 it is recommended that you mount the out door siren at entrance door top of garage door or any location which is sheltered from easy tampering and rain 11 REMOTE CONTROL UNIT BATTERY REPLACEMENT Battery Type A76 or 1844 1 Remove the battery compartment cover by sliding it in the direction of the arrow 2 Replace with three new batteries of the same type Making sure the polarity or of the batteries match polarity marks inside the unit As shown in Fig 11 Fig 11 3 Replace battery cover Notes remote operation If intermittent r
7. will keep the unit working Fig 2 3 Connect the extended outdoor Siren cable to the termi nal post located jn the back of the main unit inside the battery compartment See Polarity shown in Fig 3 Black Striped Wire To Negative 4 To connect the magnetic sensor of WINDOW to main unit option Do not remove short bar until install magnetic sensor Measure the amount of wire needed to connect the sensor to the transmitter then cut the wire to the correct length Strip about 1 2 incn of insulation from the wires ends and twist the strands together B Connect another sensor switch screw to the main terminal post using the wire you just cut There is no polarity need to take care any one terminal will be fine as long as the wires form a loop C Connect another sensor switch screw to another switch terminal post by using the parallel another wire as shown in Fig 4 Fig 4 Sensor Switch NOTE It you connect more than one sensor to the main unit connect them in series as shown in Fig 5 Main Unit Fig 5 5 How to connect the magnetic sensor of DOOR to main unit when the door is opened It will alarm after entry delay time A Please refer to point 4 method but in accordance to following Fig 6 and Fig 7 connection B There is no polarity need to take care any one terminal will be fine as long as the wires form a loop Fig 7 3 6 You can fix the main unit