Home

Harbor Freight Tools R134A Product manual

image

Contents

1. vacuum stop and disconnect the Shop Recovery S ystem Attach SKU 96677 For technical questions please call 1 800 444 3353 Page 4 this Air Vacuum Pump and run for 10 minutes to further raise the vacuum level in the A C system Attach an air pressure hose not included to the Air Fitting either by threading it directly on or by using a quick release fitting As appropriate attach the R 134a or R12 22 manifold fitting to the AC drain port of the vehicle This is a quick release fitting The drain port is generally the lower of the two R 134a or R12 22 manifold ports and will be located downstream from the compressor in the vehicle Refer to the vehicle s owners manual for vehicle specific information Tightly cap the unused port Turn on the Air Vacuum Pump by activating the air compressor not included Recommended running PSI is 75 The vacuum will build for approximately 2 minutes before reaching full power Allow the pump to draw vacuum on the system for approximately 10 minutes to thoroughly remove all moisture and any gas from the system The gauge not included should show negative pressure and maintain that reading for 10 minutes If it rises back towards 0 there may be a leak in the system Turn off the air supply before disconnecting the hose from the vacuum fitting Store the tool indoors out of children s reach MAINTENANCE AND SERVICING Unplug the tool from the air outlet before performing an AWARNING 9
2. farren SSSOSC irS Record Product s Serial Number Here Note If product has no serial number record month and year of purchase instead Note Some parts are listed and shown for illustration purposes only and are not available individually as replacement parts SKU 96677 For technical questions please call 1 800 444 3353 Page 6 LIMITED 90 DAY WARRANTY Harbor Freight Tools Co makes every effort to assure that its products meet high quality and durability standards and warrants to the original purchaser that this product is free from defects in materials and workmanship for the period of 90 days from the date of purchase This warranty does not apply to damage due directly or indirectly to misuse abuse negligence or accidents repairs or alterations outside our facilities criminal activity improper installation normal wear and tear or to lack of maintenance We shall in no event be liable for death injuries to persons or property or for incidental contingent special or consequential damages arising from the use of our product Some states do not allow the exclusion or limitation of incidental or consequential damages so the above limitation of exclusion may not apply to you THIS WARRANTY IS EXPRESSLY IN LIEU OF ALL OTHER WARRANTIES EXPRESS OR IMPLIED INCLUDING THE WARRANTIES OF MERCHANTABILITY AND FITNESS To take advantage of this warranty the product or part must be returned to us with transportation charges
3. prepaid Proof of purchase date and an explanation of the complaint must accompany the merchandise If our inspection verifies the defect we will either repair or replace the product at our election or we may elect to refund the purchase price if we cannot readily and quickly provide you with a replacement We will return repaired products at our expense but if we determine there is no defect or that the defect resulted from causes not within the scope of our warranty then you must bear the cost of returning the product This warranty gives you specific legal rights and you may also have other rights which vary from state to state 3491 Mission Oaks Blvd PO Box 6009 Camarillo CA 93011 800 444 3353 SKU 96677 For technical questions please call 1 800 444 3353 Page 7
4. CENTRAL PNEUMATIC m V AYA AIR VACUUM PUMP WITH R134A amp R12 22 Kerer 96677 SET UP AND OPERATING INSTRUCTIONS DANGER To prevent explosion serious injury and death e Service of air conditioning systems must be done only by trained and experienced technician to avoid overfilling e Technicians opening refrigeration circuit in automotive air conditioning systems MUST be certified in refrigerant recovery and recycling procedures in compliance with section 609 of Clean Air Act Amendments of 1990 For additional information regarding ozone depletion and air conditioning service regulations visit EPA s website www epa gov ozone Diagrams within this manual may not be drawn proportionally Due to continuing improvements actual product may differ slightly from the product described herein Distributed exclusively by Harbor Freight Tools 3491 Mission Oaks Blvd Camarillo CA 93011 Visit our website at http www harborfreight com Read this material before using this product Failure to do so can result in serious injury SAVE THIS MANUAL Copyright 2007 by Harbor Freight Tools All rights reserved No portion of this manual or any artwork contained herein may be reproduced in any shape or form without the express written consent of Harbor Freight Tools For technical questions or replacement parts please call 1 800 444 3353 SAVE THIS MANUAL Keep this manual for the safety warnings and precaution
5. p a inspection maintenance or cleaning procedures Damaged equipment can fail causing serious personal injury Do not use damaged equipment If abnormal noise or vibration occurs have the problem corrected before further use Cleaning maintenance and lubrication BEFORE EACH USE inspect the general condition of the tool Check for loose screws cracked or broken parts and any other condition that may affect its safe operation AFTER USE clean external surfaces of the tool with clean moist cloth SKU 96677 For technical questions please call 1 800 444 3353 Page 5 PLEASE READ THE FOLLOWING CAREFULLY THE MANUFACTURER AND OR DISTRIBUTOR HAS PROVIDED THE PARTS LIST AND ASSEMBLY DIAGRAM IN THIS MANUAL AS A REFERENCE TOOL ONLY NEITHER THE MANUFACTURER OR DISTRIBUTOR MAKES ANY REPRESENTATION OR WARRANTY OF ANY KIND TO THE BUYER THAT HE OR SHE IS QUALIFIED TO MAKE ANY REPAIRS TO THE PRODUCT OR THAT HE OR SHE IS QUALIFIED TO REPLACE ANY PARTS OF THE PRODUCT IN FACT THE MANUFACTURER AND OR DISTRIBUTOR EXPRESSLY STATES THAT ALL REPAIRS AND PARTS REPLACEMENTS SHOULD BE UNDERTAKEN BY CERTIFIED AND LICENSED TECHNICIANS AND NOT BY THE BUYER THE BUYER ASSUMES ALL RISK AND LIABILITY ARISING OUT OF HIS OR HER REPAIRS TO THE ORIGINAL PRODUCT OR REPLACEMENT PARTS THERETO OR ARISING OUT OF HIS OR HER INSTALLATION OF REPLACEMENT PARTS THERETO PARTS LIST amp ASSEMBLY DIAGRAM Part Description Qty e secan o e Sea Capra Jo e
6. please call 1 800 444 3353 Page 3 understood by the operator that common sense and caution are factors which cannot be built into this product but must be supplied by the operator SAVE THESE INSTRUCTIONS SPECIFICATIONS Air Pressure Range 75 180 PSI Recommended Air Pressure 75 PSI Air Consumption 4 2 CFM 90 PSI UNPACKING When unpacking check to make sure that the item is intact and undamaged If any parts are missing or broken please call Harbor Freight Tools at the number shown on the cover of this manual as soon as possible OPERATING INSTRUCTIONS Read the ENTIRE IMPORTANT SAFETY INFORMATION section at the A beginning of this manual including all text under subheadings therein before set up or use of this product General operating instructions NOTE While not required for operation it is advisable to mount a quick release air fitting to the Air Fitting This will make it easier to quickly attach and detach the air supply hose from this tool Warning It is unlawful and hazardous to discharge refrigerants into the atmosphere Before beginning work with this tool safely capture refrigerants using an approved refrigerant recovery system and dispose of them properly Contact the EPA for important certification regulations and other regulations that apply see front cover 1 Turn vehicle and AC system OFF 2 Attach shop A C Refrigerant Recovery System Drain refrigerant After reaching 26 to 28 in hg
7. r pneumatic tool serviced by a qualified repair person using only identical replacement parts This will ensure that the safety of the tool is maintained SPECIFIC SAFETY RULES Maintain labels and nameplates on the tool These carry important safety information If unreadable or missing contact Harbor Freight Tools for a replacement Avoid unintentional starting Prepare to begin work before turning on the tool Do not leave the tool unattended when it is plugged into a pneumatic outlet unplug it before leaving This product is not a toy Keep it out of reach of children People with pacemakers should consult their physician s before use Electromagnetic fields in close proximity to heart pacemaker could cause pacemaker interference or pacemaker failure Caution is necessary when near coil spark plug cables or distributor of running engine Engine should be off during vacuum evacuation WARNING The brass components of this product contain lead a chemical known to the State of California to cause birth defects or other reproductive harm California Health amp Safety code 25249 5 et seq NEVER use this product to vent refrigerants into the air It is illegal to do so harmful to the environment and poses a serious health risk The warnings precautions and instructions discussed in this instruction manual cannot cover all possible conditions and situations that may occur It must be SKU 96677 For technical questions
8. s assembly operating inspection maintenance and cleaning procedures Write the product s serial number in the back of the manual near the assembly diagram or month and year of purchase if product has no number Keep this manual and the receipt in a safe and dry place for future reference GENERAL SAFETY RULES WARNING Read all instructions Failure to follow all instructions listed below may result in electric shock fire and or serious injury The term pneumatic tool in all of the warnings listed below refers to your pneumatic powered Air Vacuum Pump SAVE THESE INSTRUCTIONS 1 Work area safety a Keep work area clean and well lit C uttered or dark areas invite accidents b Keep children and bystanders away while operating a pneumatic tool Distractions can cause you to lose control 2 Personal safety a Stay alert watch what you are doing and use common sense when operating a pneumatic tool Do not use a pneumatic tool while you are tired or under the influence of drugs alcohol or medication A moment of inattention while operating pneumatic tools may result in serious personal injury b Use safety equipment Always wear eye protection Safety equipment such as dust mask work gloves non skid safety shoes hard hat or hearing protection used for appropriate conditions will reduce personal injuries c Dress properly Do not wear loose clothing or jewelry Keep your hair clothing and gloves away from moving par
9. ts Loose clothes jewelry or long hair can be caught in moving parts d If devices are provided for the connection of chemical vapor extraction and collection facilities ensure these are connected and properly used Use of these devices can reduce vapor related hazards 3 Pneumatic tool use and care a Do not force the pneumatic tool Use the correct pneumatic tool for your application The correct pneumatic tool will do the job better and safer at the rate for which it was designed b Disconnect the tool from the air source before making any adjustments changing accessories or storing SKU 96677 For technical questions please call 1 800 444 3353 Page 2 c Store idle pneumatic tools out of the reach of children and do not allow persons unfamiliar with the pneumatic tool or these instructions to operate it Pneumatic tools are dangerous in the hands of untrained users d Maintain pneumatic tools Check for misalignment or breakage of parts and any other condition that may affect the pneumatic tools operation If damaged have it repaired before use Many accidents are caused by poorly maintained tools e Use the pneumatic tool in accordance with these instructions and in the manner intended for the particular type of tool taking into account the working conditions and the work to be performed Use of the pneumatic tool for operations different from those intended could result in a hazardous situation Service a Have you

Download Pdf Manuals

image

Related Search

Related Contents

Índice    Viewsonic Value Series 20" VA2016w LCD  GSi DMC-122 Editor – User`s Manual Editor v. 1.00 – User`s Manual  bedienungsanleitung user manual mode d`emploi manual del usuario  B&B Electronics 855-11622 network media converter  B75H2-M2 USER MANUAL Preface    

Copyright © All rights reserved.
Failed to retrieve file