Home

Harbor Freight Tools 93442 User's Manual

image

Contents

1. CASCADING FOUNTAIN ASSEMBLY AND OPERATING INSTRUCTIONS Diagrams within this manual may not be drawn proportionally Due to continuing improvements actual product may differ slightly from the product described herein Distributed exclusively by Harbor Freight Tools 3491 Mission Oaks Blvd Camarillo CA 93011 Visit our website at http www harborfreight com Read this material before using this product Failure to do so can result in serious injury SAVE THIS MANUAL Copyright 2005 by Harbor Freight Tools All rights reserved No portion of this manual or any artwork contained herein may be reproduced in any shape or form without the express written consent of Harbor Freight Tools For technical questions or replacement parts please call 1 800 444 3353 PRODUCT SPECIFICATIONS ee Electrical Requirements 120 VAC 60Hz 0 04 AMPs Power Cord 6 3 18AWG x3 C Power Plug 3 Prong Water Pump Self Priming with Intake Filter 1 4 Outlet Nipple Unit Weight SAVE THIS MANUAL You will need this manual for the safety warnings and precautions assembly operating inspection maintenance and cleaning procedures parts list and assembly diagram Keep your invoice with this manual Write the invoice number on the inside of the front cover Keep this manual and invoice in a safe and dry place for future reference GENERAL SAFETY RULES WARNING READ AND UNDERSTAND ALL INSTRUCTIONS Failure to follow al
2. da Oo ia J da B E 16 16 16 16 16 16 16 16 16 1 q4 12 12 10 12 1 150 Oo o dia J o e y w S 156 1 200 a e a a Based on limiting the line wo dro to fie volte at 150 of the ed ae FIGURE D 3 51 70 7 1 12 0 l l l l MIME loin SKU 93442 For technical questions please call 1 800 444 3353 PAGE 8 SYMBOLOGY Double Insulated Canadian Standards Association Underwriters Laboratories Inc Volts Alternating Current No Load Revolutions jper Minute RPM UNPACKING When unpacking check to make sure all the parts shown on the Parts List on page 13 are included If any parts are missing or broken please call Harbor Freight Tools at the number shown on the cover of this manual as soon as possible ASSEMBLY AND OPERATING INSTRUCTIONS For additional information regarding the parts listed in the following pages refer to the Assembly Diagram on page 13 WARNING DROWNING HAZARD KEEP OUT OF SMALL CHILDREN S REACH AA CAUTION Always make sure the Pump 9 is disconnected from its electrical outlet prior to assembling the Fountain adding any water or performing service to the product Assembly Instructions 1 NOTE Assembly will require the assistance of another person 2 Place the Bottom Stand 1 in the location where the Fountain is to be used See Assy Diagram Attach the Vertical Stand 2 to the Bottom Stand 1 See Assy Diagram 4 Attach the
3. If unreadable or missing contact Harbor Freight Tools for a replacement Wear ANSI approved safety impact eye goggles and heavy duty work gloves when assembling the Fountain Using personal safety devices reduce the risk for injury Safety impact eye goggles and heavy duty work gloves are available from Harbor Freight Tools SKU 93442 For technical questions please call 1 800 444 3353 PAGE 4 10 11 12 13 Maintain a safe environment Keep the area well lit Make sure there is ade quate surrounding space Always keep the area free of obstructions grease oil trash and other debris Do not use an electrically powered product in areas near flammable chemicals dusts and vapors Never leave the Fountain unattended when it is plugged into an electrical outlet Turn off the Fountain before leaving Carefully inspect the condition of the Fountain before use and check the Fountain continually during use If any damage is noted stop immediately and repair or replace the Fountain Make sure the Pump 9 is unplugged from its electrical outlet prior to performing any inspection maintenance or cleaning procedures CAUTION Excessive weight or pressure on any of the Fountain sections may cause it to tip and or fall Keep children and pets away from any of the Fountain sections and the Power Cord The ceramic Bowls 5 6 7 are fragile and can be easily damaged Handle with care This Fountain is designed for use
4. does not fit contact a qualified electrician to install a polarized outlet Do not change the plug in any way Double insulation O eliminates the need for the three wire grounded power cord and grounded power supply system Avoid body contact with grounded surfaces such as pipes radiators ranges and refrigerators There is an increased risk of electric shock if your body is grounded Do not abuse the Power Cord Never use the Power Cord to carry this product or pull the Plug from an outlet Keep the Power Cord away from heat oil sharp edges or moving parts Replace damaged Power Cords immediately Damaged Power Cords increase the risk of electric shock When operating this product outside use an outdoor extension cord marked W A or W These extension cords are rated for outdoor use and reduce the risk of electric shock PERSONAL SAFETY Stay alert Watch what you are doing and use common sense when operating this product Do not use the Fountain while tired or under the influence of drugs alcohol or medication A moment of inattention while operating this product may result in serious personal injury Avoid accidental starting Make sure the Power Cord remains unplugged from its electrical outlet until this product is completely assembled filled with water and ready to use Do not overreach Keep proper footing and balance at all times Proper footing and balance enables better control of this product in unexpec
5. or three wire extension cord 2 As the distance from the supply outlet increases you must use a heavier gauge extension cord Using extension cords with inadequately sized wire causes a serious drop in voltage resulting in loss of power and possible tool damage See Figure D 3 The smaller the gauge number of the wire the greater the capacity of the cord For example a 14 gauge cord can carry a higher current than a 16 gauge cord See Figure D 4 When using more than one extension cord to make up the total length make sure each cord contains at least the minimum wire size required See Figure D 9 lf you are using one extension cord for more than one tool add the nameplate amperes and use the sum to determine the required minimum cord size See Figure D 6 If you are using an extension cord outdoors make sure it is marked with the suf fix W A W in Canada to indicate it is acceptable for outdoor use 7 Make sure your extension cord is properly wired and in good electrical condition Always replace a damaged extension cord or have it repaired by a qualified elec trician before using it 8 Protect your extension cords from sharp objects excessive heat and damp or wet areas SME MNO E O TTT WAR AN OH ES ASR CIAL 20 VOLT ha WEF LA TE EXTENSION CORD LEMN TH O 2 0 A WMF ER ES Fr S0 75 100 Feet Feet Feet Feet Feet 1 at Full Load o o ia J de g eT ee ee 25 50 o o ia J de o ia J 6
6. Middle Stand 8 to the Vertical Stand 2 and Bottom Stand 1 See Assy Diagram SKU 93442 For technical questions please call 1 800 444 3353 PAGE 9 5 Attach the Top Stand 4 to the Vertical Stand 2 and Middle Stand 3 See Assy Diagram 6 Carefully set the Large Bowl 5 on the Bottom Stand 1 See Assy Diagram 7 Carefully set three Small Bowls 6 on the Middle Stand 3 and Top Stand 4 See Assy Diagram 8 Carefully set the Jug 7 on the Top Stand 4 See Assy Diagram 9 Route the Hose 8 downward into the Large Bowl 5 See Assy Diagram 10 Set the Pump 9 in the middle of the Large Bowl 5 See Assy Diagram 11 Connect the Hose 8 to the Pump 9 See Assy Diagram 12 Make sure the Fountain is unplugged from its electrical outlet Then move the Flow Regulator of the Pump 9 towards the position NOTE After running the Fountain it may be necessary to adjust the rate of water flow If so disconnect the Pump from its electrical outlet Moving the Flow Regulator towards the position increases the rate of flow Moving the Flow Regulator towards the position decreases the rate of flow See Figure F 13 Fill the Large Bowl 5 with a minimum 2 of water Do not overfill the Large Bowl See Assy Diagram and Figure F MINIMUM WATER LEVEL FOR BEST RESULTS COMPLETELY SUBMERGE THE PUMP FLOW REGULATOR FIGURE F SKU 93442 For technical que
7. ater traveling along the Power Cord and coming in contact with the outlet If the Power Cord Plug or outlet does get wet do not unplug the Power Cord Plug Disconnect the fuse or circuit breaker that supplies power to the electrical outlet Then unplug the Power Cord and examine for presence of water in the outlet See Figure A 16 A WARNING People with pacemakers should consult their physician s be fore using this product Operation of electrical equipment in close proximity to a heart pacemaker could cause interference or failure of the pacemaker 17 A WARNING The warnings and cautions discussed in this manual cannot cover all possible conditions and situations that may occur It must be understood by the operator that common sense and caution are factors which cannot be built into this product but must be supplied by the operator SAVE THESE INSTRUCTIONS POWER CORD 120 VOLT GROUNDED ELECTRICAL OUTLET DRIP LOOP ae FIGURE A SKU 93442 For technical questions please call 1 800 444 3353 PAGE 6 GROUNDED TOOLS TOOLS WITH THREE PRONG PLUGS 1 Tools marked with Grounding Required have a three wire cord and three prong grounding plug The plug must be connected to a properly grounded outlet If the tool should electrically malfunction or break down grounding provides a low resistance path to carry electricity away from the user reducing the risk of electric shock See Figure B 2 The grounding prong in the
8. g 3 Middle Stand 1 8 Hose 1 4 TopStand 1 9 Pump 1 5 lageBow tt T NOTE Some parts are listed and shown for illustration purposes only and are not available individually as replacement parts SKU 93442 For technical questions please call 1 800 444 3353 PAGE 13 ea SSS S ese Casing CdS aa d tering Cover id i i 6 said Rotor Ci fsa SS Pp Housing O T 6 wao ewa poo u 10A 11A REV 09c SKU 93442 For technical questions please call 1 800 444 3353 PAGE 14
9. l instructions listed below may result in electric shock fire and or serious injury SAVE THESE INSTRUCTIONS WORK AREA 1 Keep your work area clean and well lit Cluttered benches and dark areas invite accidents P Do not operate this product in explosive atmospheres such as in the presence of flammable liquids gases or dust Electrically charged products create sparks which may ignite the dust or fumes O Keep bystanders children and visitors away while operating a this product Distractions can cause you to lose control Protect others in the work area from debris such as chips and sparks Provide barriers or shields as needed ELECTRICAL SAFETY 4 Grounded products must be plugged into an outlet properly installed and REV 09c SKU 93442 For technical questions please call 1 800 444 3353 PAGE 2 10 11 grounded in accordance with all codes and ordinances Never remove the grounding prong or modify the plug in any way Do not use any adapter plugs Check with a qualified electrician if you are in doubt as to whether the outlet is properly grounded If the product should electrically malfunction or break down grounding provides a low resistance path to carry electricity away from the user Double insulated products are equipped with a polarized plug one blade is wider than the other This plug will fit in a polarized outlet only one way If the plug does not fit fully in the outlet reverse the plug If it still
10. mp Filter will greatly reduce performance of the Fountain To clean the Pump Filter remove the Front Plate of the Pump to expose the Filter Use a stream of clean water to clean the Filter and Impeller area inside the Pump Then replace the Front Plate 4 Make sure the water supply used for the Fountain is not dirty sandy and does not contain any corrosive chemical products Change the water when necessary and rinse out the ceramic Bowls 5 6 7 frequently SKU 93442 For technical questions please call 1 800 444 3353 PAGE 11 5 When storing make sure to store the Fountain in a clean dry safe location out of reach of children 6 AA CAUTION All maintenance service or repairs not mentioned in this manual must only be performed by a qualified service technician WARNING mproperly connecting the grounding wire can result in the risk of electric shock Check ith a qualified electrician if you are in doubt as to whether the outlet is properly grounded Do not modify the power cord plug provided with the tool Never remove the grounding orong from the plug Do not use the tool if the power cord or plug is damaged If damaged ave it repaired by a service facility before use If the plug will not fit the outlet have a oroper outlet installed by a qualified electrician TROUBLESHOOTING The Pump 9 is plugged in but fails to Make sure the Power Cord of the Pump is plugged into operate a working 120 volt grounded electrical outle
11. plug is connected through the green wire inside the cord to the grounding system in the tool The green wire in the cord must be the only wire connected to the tool s grounding system and must never be attached to an electrically live terminal See Figure B 3 Your tool must be plugged into an appropriate outlet properly installed and grounded in accordance with all codes and ordinances The plug and outlet should look like those in the following illustration See Figure B THIS PRODUCT USES A 120 VOLT 3 PRONG GROUNDED ELECTRICAL oy ELECTRICAL OUTLET pua A E E FIGURE B DOUBLE INSULATED TOOLS TOOLS WITH TWO PRONG PLUGS 4 Tools marked Double Insulated do not require grounding They have a special double insulation system which satisfies OSHA requirements and complies with the applicable standards of Underwriters Laboratories Inc the Canadian Standard Association and the National Electrical Code See Figure C 5 Double insulated tools may be used in either of the 120 volt outlets shown in the following illustration See Figure C THIS PRODUCT DOES NOT USE A l 120 VOLT 2 PRONG i GROUNDED ELECTRICA Si F i ELECTRICAL OUTLETS PLUG Wr z r I e f FIGURE C SKU 93442 For technical questions please call 1 800 444 3353 PAGE 7 EXTENSION CORDS 1 Grounded tools require a three wire extension cord Double Insulated tools can use either a two
12. stions please call 1 800 444 3353 PAGE 10 Operating Instructions 1 Plug the Power Cord of the Pump 9 into the nearest 120 volt grounded electrical outlet making sure to arrange a drip loop in the Cord The Pump will now run continuously until it is unplugged from its electrical outlet See Figure G POWER CORD 120 VOLT GROUNDED ELECTRICAL OUTLET DRIP LOOP wee FIGURE G 2 Allow sufficient time for the Pump 9 to move water upward into the Jug 7 Once the Jug is filled to overflowing the water will begin cascading downward into the three Small Bowls 6 and into the Large Bowl where it will again be pumped upward to repeat the process See Assy Diagram 3 When finished using the Fountain always unplug the Power Cord from the electrical outlet Drain the Fountain of all water Then store the unit in a clean dry safe location out of reach of children INSPECTION MAINTENANCE AND CLEANING 1 A WARNING Make sure the Power Cord of the Pump 9 is disconnected from its electrical outlet prior to performing any inspection maintenance or cleaning procedures 2 Before each use inspect the general condition of the Fountain Check for cracked or broken parts damaged electrical wiring and any other condition that may affect safe operation If abnormal noise or vibration occurs have the problem corrected before further use Do not use damaged equipment 3 To clean the Pump Filter A clogged or dirty Pu
13. t Check for any damage to the Power Cord Check the fuse or circuit breaker supplying power to the electrical outlet Make sure there is at least 2 of water in the Large Bowl 5 For best results completely submerge the Pump in water Check the water intake area of the Pump for excessive debris build up If necessary clean the intake area Check the Pump Hose 8 for kinks and obstructions If necessary flush out with a garden hose Remove the Front Plate of the Pump to access the Impeller area Turn the Impeller to ensure it is not jammed or broken PLEASE READ THE FOLLOWING CAREFULLY THE MANUFACTURER AND OR DISTRIBUTOR HAS PROVIDED THE PARTS LIST AND ASSEMBLY DIAGRAM IN THIS MANUAL AS A REFERENCE TOOL ONLY NEITHER THE MANUFACTURER OR DISTRIBUTOR MAKES ANY REPRESENTATION OR WARRANTY OF ANY KIND TO THE BUYER THAT HE OR SHE IS QUALIFIED TO REPLACE ANY PARTS OF THE PRODUCT IN FACT THE MANUFACTURER AND OR DISTRIBUTOR EXPRESSLY STATES THAT ALL REPAIRS AND PARTS REPLACEMENTS SHOULD BE UNDERTAKEN BY CERTIFIED AND LICENSED TECHNICIANS AND NOT BY THE BUYER THE BUYER ASSUMES ALL RISKS AND LIABILITY ARISING OUT OF HIS OR HER REPAIRS TO THE ORIGINAL PRODUCT OR REPLACEMENT PARTS THERETO OR ARISING OUT OF HIS OR HER INSTALLATION OF REPLACEMENT PARTS THERETO SKU 93442 For technical questions please call 1 800 444 3353 PAGE 12 PARTS LIST AND ASSEMBLY DIAGRAM 1 Bottom Stand 1 6 SmarBom 3 2 Vertical Stand 1 7 u
14. ted situations SKU 93442 For technical questions please call 1 800 444 3353 PAGE 3 12 Use safety equipment Wear eye protection when assembling this product Non skid safety shoes must be used for appropriate conditions TOOL USE AND CARE 13 Disconnect the Power Cord Plug from the power source before making any adjustments changing accessories or storing the Fountain Such preventive safety measures reduce the risk of starting the unit accidentally 14 Store idle equipment out of reach of children and other untrained persons Electrically powered products are dangerous in the hands of untrained users 15 Check for misalignment or binding of moving parts breakage of parts and any other condition that may affect this product s operation If damaged have the Fountain serviced before using Many accidents are caused by poorly maintained equipment 16 Service must be performed only by qualified repair personnel Service or maintenance performed by unqualified personnel could result in a risk of injury 17 When servicing this product use only identical replacement parts Follow instructions in the Inspection Maintenance And Cleaning section of this manual Use of unauthorized parts or failure to follow maintenance instructions may create a risk of electric shock or injury SPECIFIC SAFETY RULES 1 Maintain labels and nameplates on the Fountain Save this instruction manual These carry important information
15. with cold clean water only Do not use water over 85 degrees Fahrenheit as it will damage the inner seals of the Pump 9 may occur Do not use this Fountain with any other liquids Make sure the water supply used for the Fountain is not dirty sandy and does not contain any corrosive chemical products Change the water when necessary and rinse out the ceramic Bowls 5 6 7 frequently Running the Pump 9 without sufficient water can damage the Pump This Pump requires a minimum of 2 inches of water at all times If locating the Fountain on a ground surface make sure the surface is flat level and dry If locating the Fountain on a table make sure the table is flat level dry and sturdy enough to support the weight of the Fountain and its water Always keep the Fountain out of reach of children Avoid accidental electric shock Keep all electrically powered products away from the Fountain Disconnect the Pump 9 from its electrical outlet before placing hands in a ceramic Bowl 5 6 7 filled with water Make sure to stand on a dry insulated surface such as a rubber mat while using the Fountain SKU 93442 For technical questions please call 1 800 444 3353 PAGE 5 15 Always arrange a drip loop in the Power Cord connecting the Pump 9 to a 120 volt grounded electrical outlet A drip loop is that part of the Power Cord below the level of the electrical outlet or the connector if an extension cord is used to prevent w

Download Pdf Manuals

image

Related Search

Related Contents

ECS 350 DUAL SYSTEM  BOSE® BLUETOOTH® HEADSET SERIES 2  ddc-svc-man-0006    Whirlpool W10443041B-SP User's Manual  fulltext  -プ内の導線が切れる原因になります~ 水深が3cm以上ないと、 使用    VCT-1170RM  

Copyright © All rights reserved.
Failed to retrieve file