Home

Harbor Freight Tools 1650 PSI 1.25 GPM Electric Pressure Washer Product manual

image

Contents

1. c Insert the Extension Nozzle into the Dispenser cap pressing and twisting until it clicks into place shown at right 3 Before connecting the water supply run water through the garden hose sold separately to remove any debris OPERATION 4 Turn off the water then thread the garden hose onto the Water Supply Inlet on the front of the Pressure Washer 5 Plug the Power Cord into a power outlet and test the GFCI by pressing the Reset Button then the Test button then the Reset Button again as described in Controls and Features section Reset Button Note The Pressure Washer will not work if the GFCI is not properly reset Test Button Item 69488 For technical questions please call 1 888 866 5797 Page 11 General Operating Instructions 1 Point the Nozzle in a safe direction Press in the Note If the unit does not turn on or turns off Safety Lock Button to unlock the Trigger and suddenly check and reset the GFCI squeeze the Trigger to check that all pressure is released from the unit Release the Trigger 4 Unlock the Safety Lock Button and squeeze the Trigger to start the stream Be aware that Note The Gun s safety lock feature locks the when it is first started the gun will kick back Trigger when not in use To unlock the unit and use the gun press the Safety Lock Button 5 Test spray the edge of the surface to be cleaned and squeeze the Trigger The safety lock will to make sure that the stream i
2. Up 1 Page 10 Designate a work area that is clean and well lit The work area must not allow access by children or pets to prevent distraction and injury CHECK THE WATER SUPPLY Prior to using the Pressure Washer for the first time it is ESSENTIAL to verify that the water supply is adequate The Pressure Washer needs TWICE the water supply or volume than the listed water output 1 3 GPM This Pressure Washer will need about 2 6 3 GPM to operate correctly and efficiently If the water is being supplied by a well pump make certain that the well oump produces enough water to keep up with the Pressure Washer s water demands Water supply hoses should be heavy duty to withstand the forces involved Water hoses up to 25 long must be 5 g ID Water hoses up to 50 long must be 3 4 ID Do not use hoses longer than 50 The more minerals in the water the harder the water you use the more often mineral buildup will need to be cleaned out from the nozzles The flow rate of the water supply must never be allowed to fall below 2 6 GPM To determine the water supply s flow rate Run the water at full for one minute into a 5 gallon container and measure the amount of water in the container CAUTION If the Pressure Washer is run with an inadequate water supply the pump will cavitate Cavitation causes the pump to operate loudly and will damage it ARRANGE FOR A PROPER ELECTRICAL SUPPLY This unit uses a large amount of cur
3. circuit breaker If breaker is tripped make sure circuit is right capacity for tool and circuit has no other loads Press reset button on GFCI unit on cord Have a qualified technician service tool Press reset button on GFCI unit on cord SHOCK HAZARD IMMEDIATELY discontinue use Have the unit repaired by a qualified technician before further use Check water supply hose for kinks leaks or blockage Open faucet all the way Check that all connections are tight Remove Filter and clean Pressure is created by the Nozzle not the Spray Gun Attach Extension Nozzle to unit Remove Nozzle and clean Remove Nozzle and clean with vinegar Recommended garden hose length is 20 to 50 feet or 30 feet if using well water Shorten the length of the garden hose if needed to increase pressure Have a qualified technician service tool Safety lock is still engaged Press in on the release button on the bottom of the Spray Gun Handle to release the Safety Lock Check that the detergent is the recommended type of detergent Clean out dispenser and replace with correct type if needed Clean unit with a de mineralizing solution such as vinegar or other aqueous acidic cleaner Follow all safety precautions whenever diagnosing or servicing the tool Disconnect power supply before service Item 69488 For technical questions please call 1 888 866 5797 MAINTENANCE Page 15 m g
4. damage is noted from the pressure setting use a lighter setting when cleaning the rest of the area If damage or discoloration is noted from the detergent do not use it when cleaning 6 First pass over the area with a light cleaning and then more thoroughly clean it Item 69488 For technical questions please call 1 888 866 5797 For a vertical or sloped surface a Wash from the top down b If possible direct the stream in the same direction as the slope towards a draining area This will enable better drainage and therefore better cleaning For a flat surface a Ifa thin layer of water accumulates on the surface periodically use the stream to direct this water towards the drainage b After the major cleaning is done sweep the surface with the stream to help direct loose debris toward the drainage If detergent is to be applied Only use pressure washing detergent in the soap dispenser other detergents will clog the dispenser Do not add detergent to the body of the pressure washer Spray the surface with detergent until evenly covered then turn off the machine and water source release pressure and remove the soap dispenser Allow the detergent several minutes to sit and soak into the work surface this will improve cleaning efficiency Turn on the water source and power and rinse off all detergent completely Hold the Spray Gun at about a 45 angle and steadily sweep the stream back and forth if a seve
5. Do not smoke during use Nicotine reduces extended period should first be examined by a the blood supply to the hands and fingers gt doctor and then have regular medical check increasing the risk of vibration related injury ups to ensure medical problems are not being LLI caused or worsened from use Pregnant women 3 Wear suitable gloves to reduce the LL or people who have impaired blood circulation vibration effects on the user F to the hand past hand injuries nervous system 00 4 Use tools with the lowest vibration when there disorders diabetes or Raynaud s Disease should 3 f is a choice between different processes not use this tool If you feel any medical or physical symptoms related to vibration such as 5 Include vibration free periods each day of work tingling numbness and white or blue fingers seek medical advice as soon as possible 6 To reduce vibration maintain the tool as explained in this manual If any abnormal vibration occurs stop use immediately Service Precautions Ground Fault Circuit Interrupter Protection This pressure washer is provided with a ground fault circuit interrupter GFCI built into the plug of the power supply cord This device provides additional protection from the risk of electric shock Should replacement of the plug or cord become necessary use only identical replacement parts that include GFCI protection Servicing a Double Insulated Appliance In a double ins
6. EITHER THE MANUFACTURER OR DISTRIBUTOR MAKES ANY REPRESENTATION OR WARRANTY OF ANY KIND TO THE BUYER THAT HE OR SHE IS QUALIFIED TO MAKE ANY REPAIRS TO THE PRODUCT OR THAT HE OR SHE IS QUALIFIED TO REPLACE ANY PARTS OF THE PRODUCT IN FACT THE MANUFACTURER AND OR DISTRIBUTOR EXPRESSLY STATES THAT ALL REPAIRS AND PARTS REPLACEMENTS SHOULD BE UNDERTAKEN BY CERTIFIED AND LICENSED TECHNICIANS AND NOT BY THE BUYER THE BUYER ASSUMES ALL RISK AND LIABILITY ARISING OUT OF HIS OR HER REPAIRS TO THE ORIGINAL PRODUCT OR REPLACEMENT PARTS THERETO OR ARISING OUT OF HIS OR HER INSTALLATION OF REPLACEMENT PARTS THERETO Record Product s Serial Number Here MAINTENANCE Note If product has no serial number record month and year of purchase instead Note Some parts are listed and shown for illustration purposes only and are not available individually as replacement parts Item 69488 For technical questions please call 1 888 866 5797 Page 19 Limited 90 Day Warranty Harbor Freight Tools Co makes every effort to assure that its products meet high quality and durability standards and warrants to the original purchaser that this product is free from defects in materials and workmanship for the period of 90 days from the date of purchase This warranty does not apply to damage due directly or indirectly to misuse abuse negligence or accidents repairs or alterations outside our facilities criminal activity improper installation normal wear an
7. Owner s Manual amp Safety Instructions Save This Manual Keep this manual for the safety warnings and precautions assembly operating inspection maintenance and cleaning procedures Write the product s serial number in the back of the manual near the assembly diagram or month and year of purchase if product has no number Keep this manual and the receipt in a safe and dry place for future reference Reve ITEM 69488 PAGIFICHYDROSTAR 1650 PSI ELECTRIC PRESSURE WASHER Visit our website at http www harborfreight com Email our technical support at productsupport harborfreight com When unpacking make sure that the product is intact and undamaged If any parts are missing or broken please call 1 888 866 5797 as soon as possible Copyright 2011 by Harbor Freight Tools All rights reserved A 5 F No portion of this manual or any artwork contained herein may be reproduced in Read this material before using this product any shape or form without the express written consent of Harbor Freight Tools Failure to do so can result in serious injury Diagrams within this manual may not be drawn proportionally Due to continuing SAVE THIS MANUAL improvements actual product may differ slightly from the product described herein Tools required for assembly and service may not be included Table of Contents SCL PE E E E E ATE E E E 3 Mantena e an a e 14 SEUD penaa a ea 7 Parts Lists and Assembly Diagrams 16 Specifica
8. TO PREVENT SERIOUS INJURY FROM ACCIDENTAL OPERATION Turn the Power Switch of the tool off unplug the tool from its electrical outlet shut off the water supply and safely discharge all residual water pressure from the unit before assembling or making any adjustments to the tool SETUP Components _ Soap lt lt _ Dispenser Handle lt Extension GP wze Trigger Body Pressure Hose Outlet on back Spray Gun Power Safety Lock Switch Button Water Supply Inlet High Pressure Hose Figure A Item 69488 For technical questions please call 1 888 866 5797 Page 7 Assembly Note For additional information regarding the parts listed in the following pages refer to Parts Lists and Assembly Diagrams on page 16 Some of the following assembly steps may have been performed at the factory 1 Check the Inlet Strainer for any blockage including packaging debris Remove any plastic plugs from the water inlet outlet 2 Attach the Gun Extension Nozzle holder to the side of the body 3 Attach the Handle to the front of the Body with the four included Screws 4 Thread the High Pressure Hose onto the Pressure Hose Outlet on the back of the body 5 Pull the tab at the base of the Spray Gun away from the port To secure the High Pressure Hose afl 2 N b a Insert it firmly into the Spray Gun and b press the tab towards the hose to secure it in place Page 8 For technical question
9. and Lubrication 1 Page 14 Before each use inspect the general condition of the Pressure Washer Check for loose screws misalignment or binding of moving parts damaged electrical wiring damaged High Pressure Hose damaged accessories and any other condition that may affect its safe operation If abnormal noise or vibration occurs have the problem corrected before further use Do not use damaged equipment To clean remove excess water from the Pump by tipping the unit to drain any remaining water from the inlet and outlet fittings Drain the Detergent Dispenser and flush with running water Use only a clean cloth and mild detergent to clean the body of the Pressure Washer Do not use solvents Do not immerse any part of the tool in liquid Dry off any remaining water on all parts and fittings Remove mineral deposits from the nozzle using a thin stiff wire brush The more minerals that are dissolved in the water the harder the water you use the more often mineral buildup will need to be cleaned out from inside nozzle 3 In areas that have hard water water rich in minerals such as calcium the unit will need to be cleaned periodically to remove calcium buildup which can clog the system To clean off calcium buildup Unplug the unit and lay it face down Fill the body at the water inlet fitting with calcium remover and allow at least 5 hrs for calcium deposit to break down Rinse and dry STORAGE When stori
10. cation which is protected from any water from the cleaning area Select a location higher than the cleaning area The pressure washer s location should be close enough so that the hose will reach every portion of the job to be done with some slack for movement Also select an area with proper access to a dedicated circuit Route the power cord along a safe route to reach the work area without creating a tripping hazard or exposing the power cord to possible damage The power cord must reach the work area with enough extra length to allow free movement while working PACIFIGHYDROSTAR For technical questions please call 1 888 866 5797 Item 69488 Tool Set Up AWARNING TO PREVENT SERIOUS INJURY FROM ACCIDENTAL OPERATION Turn the Power Switch of the pressure washer off unplug it from its electrical outlet and relieve all pressure in a safe manner before making adjustments or installing accessories 1 MAKE SURE THE WASHER IS CLEAN AND READY FOR USE Ensure the inlet water strainer nozzle and the rest of the Washer are completely free of buildup or debris 2 If using the Extension Nozzle insert it into the end of the gun pressing in and twisting until it clicks into place Cp D _ gt p If using the Soap Dispenser a Remove the dispenser lid and fill with pressure washer detergent sold separately b Set the spray to the fan setting by turning the end of the Extension Nozzle counterclockwise ne
11. cold water only Never use hot water Do not dry run this product Dry running will cause serious damage to the seals To avoid electrical shock never start and run the Pressure Washer in the rain Never allow water to leak into the Body of the Pressure Washer Do not direct discharge stream at the Pressure Washer itself or at other live electrical equipment Do not allow the GFCI Plug to become wet Always place the GFCI Plug in a dry location and as far away as possible from the object being sprayed DO NOT use an extension cord with this product When using the Pressure Washer always maintain a firm grip on the Spray Gun Squeezing the Trigger of the Spray Gun causes a kickback force Do not feed already pressurized water such as that from another pressure washer into this washer People with pacemakers should consult their physician s before use Electromagnetic fields in close proximity to heart pacemaker could cause pacemaker interference or pacemaker failure 19 For technical questions please call 1 888 866 5797 WARNING The brass components of this product contain lead a chemical known to the State of California to cause cancer and birth defects or other reproductive harm California Health amp Safety Code 25249 5 et seq WARNING The cord of this product contains lead and or di 2 ethylhexyl phthalate DEHP chemicals known to the State of California to cause cancer and birth def
12. d balance at all times 8 Follow the maintenance instructions specified in the manual 9 This product Is provided with A Ground Fault Circuit Interrupter GFCI built into the power cord plug If replacement of the plug or cord is needed use only identical replacement parts 10 WARNING Risk of injection or injury do not direct discharge stream at persons Set up Precautions 1 The work area should have adequate 4 drainage to reduce the possibility of a fall or electric shock due to wet surfaces 2 Wear ANSI approved safety goggles during set up and use 3 Only feed cold clean water through this tool Pressure washer detergent may be used in the soap dispenser only Do not use caustic materials solvents flammable materials or detergents not designed for pressure washers Use of any such material can cause injury or damage this tool or personal property Item 69488 WARNING When using this product basic precautions should WARNING To reduce the risk of electrocution For technical questions please call 1 888 866 5797 Connect to individual branch circuit only SAFETY keep all connections dry and off the ground Do not touch plug with wet hands Do not abuse the cord Never use the cord for carrying pulling or unplugging the pressure washer Keep cord away from heat oil sharp edges or moving parts Damaged or entangled cords increase the risk of electric shock GFCI PRECAUTIONS Test GFCI G
13. d tear or to lack of maintenance We shall in no event be liable for death injuries to persons or property or for incidental contingent special or consequential damages arising from the use of our product Some states do not allow the exclusion or limitation of incidental or consequential damages so the above limitation of exclusion may not apply to you THIS WARRANTY IS EXPRESSLY IN LIEU OF ALL OTHER WARRANTIES EXPRESS OR IMPLIED INCLUDING THE WARRANTIES OF MERCHANTABILITY AND FITNESS To take advantage of this warranty the product or part must be returned to us with transportation charges prepaid Proof of purchase date and an explanation of the complaint must accompany the merchandise If our inspection verifies the defect we will either repair or replace the product at our election or we may elect to refund the purchase price if we cannot readily and quickly provide you with a replacement We will return repaired products at our expense but if we determine there is no defect or that the defect resulted from causes not within the scope of our warranty then you must bear the cost of returning the product This warranty gives you specific legal rights and you may also have other rights which vary from state to state PAGIFICHYDROSTAR 3491 Mission Oaks Blvd e PO Box 6009 Camarillo CA 93011 1 888 866 5797
14. ects or other reproductive harm Wash hands after handling California Health amp Safety Code 25249 5 et seq Use the correct equipment for the application Do not modify the equipment and do not use the equipment for a purpose for which it is not intended If water is leaking out of the Pressure Washer immediately turn off the unit Unplug the Pressure Washer and discharge all pressure before tightening fittings or having repair work done by a qualified technician The high pressure water flow can damage the work surface if not used properly Always test the spray in an open area first Injection Hazard The high pressure water jet produced by this tool can cut skin or cause injury to hands or eyes Do not allow spray to strike you and do not spray toward people or animals Do not spray the tool itself or any electrical source This Pressure Washer is intended for outdoor residential use only In case of an emergency during use immediately release the trigger on the spray handle turn the power switch off and then unplug the unit Do not set the spray handle down without turning off the power switch Item 69488 Vibration Hazard This tool vibrates during use Repeated or long term exposure to vibration may cause temporary or permanent physical injury particularly to the hands arms and shoulders To reduce the risk of vibration related injury 1 Anyone using vibrating tools regularly or for an 2
15. ng empty the Pressure Washer of water Frost will damage the Pressure Washer if the unit contains water Store the Pressure Washer in a dry frost free room Flush the unit with automotive antifreeze prior to long term storage Dispose of antifreeze according to local ordinances A WARNING If the supply cord or GFCI unit of this power tool is damaged it must be replaced only by a qualified service technician Note Pump gearbox oil type is SAE 15W 40 gr 70 For technical questions please call 1 888 866 5797 Item 69488 Troubleshooting Possible Causes Likely Solutions Pressure Washer will not start Pressure Washer stops suddenly Output pressure varies Trigger does not depress Detergent will not dispense Performance decreases over time 1 2 Cord not connected No power at outlet GFCI circuit breaker tripped Internal damage or wear Carbon brushes or switch for example GFCI circuit breaker tripped Water leaking from housing Not enough water supply 2 Air in water supply Water Inlet Filter is clogged 4 Extension Nozzle not attached to Spray Gun Nozzle is clogged Nozzle has mineral build up Garden hose is too long Internal valves or seals may be worn or sticking Incorrect detergent type Clogged with mineral deposits 1 Check that cord is plugged in 2 Check power at outlet If outlet is unDowered turn off tool and check
16. re head on angle is used dirt may imbed in the surface being cleaned Follow a steady consistent pace during cleaning this will help prevent stripes or discoloration afterwards If streaking or uneven cleaning is noted at the end of a project go over the edges of the streaks with a wide fan pattern to help blend these lighter areas in If several different surfaces are to be cleaned be careful not to damage any of the less solid surfaces while trying to clean the harder ones This is especially a concern when cleaning tile and grout bricks and mortar or stones and mortar Z 2 m lt o Lu ou O If wood is being cleaned be careful to avoid damage Wood will usually require resurfacing sanding and re coat with a surface protectant wood stain varnish after it has dried Try to avoid leaving water on a wooden surface doing so can harm the surface Page 13 m gt Z 6 m Maintenance and Servicing AWARNING TO PREVENT SERIOUS INJURY FROM ACCIDENTAL OPERATION Turn the Power Switch of the tool off unplug the tool from its electrical outlet shut off the water supply and safely discharge all residual water pressure from the unit before performing any inspection maintenance or cleaning procedures TO PREVENT SERIOUS INJURY FROM TOOL FAILURE Do not use damaged equipment If abnormal noise or vibration occurs have the problem corrected before further use Cleaning Maintenance
17. rent especially during start up Turn off power switch then connect this unit only to a dedicated household circuit capable of providing ample current to it A dedicated circuit has no additional loads running devices connected to it shut off any appliances that slow down or lights that dim while the washer is running For best results connect the plug to that circuit s outlet that is nearest to the circuit breaker panel Read the ENTIRE IMPORTANT SAFETY INFORMATION section at the beginning of this manual including all text under subheadings therein before set up or use of this product PLAN OUT THE JOB Plan out what areas will be cleaned how many sessions will be necessary and how long the individual sessions of work will need to be Plan to clean the higher portions first because the higher portions will typically remain cleaner while the other areas are cleaned Plan a safe direction for runoff to flow while the job is being performed and plan on working your way in that direction You will have a clearer idea of the time involved to clean the area after doing a test run Clear the cleaning area of all objects that are not being cleaned If any water prone or delicate items cannot be moved protect them If detergent is to be used cover or remove any plants or animals that may be damaged by the detergent Disconnect power to and protect any nearby electrical wiring from water and spray Place the Pressure Washer in a lo
18. round Fault Circuit Interrupter before each use as follows a Plug GFCI into power outlet and press reset button Indicator should turn on b Press test button Indicator should turn off c Press reset button again for use Do not use if above test fails The GFCI device does not protect against electrical shock due to contact with both circuit conductors or a fault in any wiring supplying the GFCI device To allow GFCI unit to function properly EXTENSION CORDS MUST NOT BE USED with this pressure washer Prior to starting the Pressure Washer in cold weather check all of the parts of the unit to make sure ice has not formed Do not store the unit anywhere that the temperature will fall near 32 F 0 C Page 3 wn gt mn m lt Operating Precautions 1 Page 4 Disconnect the plug from the power source before making any adjustments changing accessories or storing pressure washers Such preventive safety measures reduce the risk of starting the pressure washer accidentally Do not leave the equipment unattended when it is running Turn off the equipment before leaving the work area Wear ANSI approved safety goggles and heavy duty nonslip rubber work boots during use Use only accessories that are recommended by Harbor Freight Tools for your model Accessories that may be suitable for one piece of equipment may become hazardous when used on another one This product must continuously run with
19. s please call 1 888 866 5797 Item 69488 Features Note Familiarize yourself with the location and function of all of the machine s controls before proceeding to setup of the machine 1 This item is equipped with a GFCI Ground Fault Circuit Interruption plug Read and follow these GFCI precautions WARNING TO PREVENT ELECTRIC SHOCK AND DEATH Test GFCI Ground Fault Circuit Interrupter before each use as follows INDICATOR RESET BUTTON TEST BUTTON Figure B a Make sure the trigger is released and plug GFCI into power outlet Press reset button Indicator should turn on b Press test button Indicator should turn off c Press reset button again for use Do not use if above test fails Item 69488 The GFCI device does not protect against electrical shock due to contact with both circuit conductors or a fault in any wiring supplying this device Should replacement of the GFCI Power Plug become necessary only a qualified technician should perform the service Do not alter or disable the GFCI Power Plug To allow the GFCI unit to function properly extension cords must not be used with this pressure washer The Spray Control Sleeve on the Spray Wand can be rotated for a range of spray patterns from a full fan spray to a direct stream spray SETUP For technical questions please call 1 888 866 5797 Page 9 e m S e zZ Operating Instructions A Work Piece and Work Area Set
20. s not too strong for re engage when you release the Trigger the surface Adjust the pressure by squeezing the Trigger more or less and by changing your distance from the surface Adjust the stream from a fan to a direct stream by turning the nozzle 6 When finished using the Pressure Washer release the Trigger turn the Power Switch off unplug the unit and turn off the water supply Trigger 7 Point the Nozzle in a safe direction and press the Safety Lock Button and squeeze the Safety Lock trigger to check that all pressure is released Button from the unit Release the Trigger 8 IMPORTANT CLEAN THE NOZZLE AFTER EVERY USE TO MAINTAIN SPRAYING POWER AND PREVENT PUMP DAMAGE a Remove the Nozzle from the Extension and twist it to open it all the way 6 Poke the end of the Tip Cleaner through the hole in the center of the Nozzle to push all debris and buildup back out the back of the Nozzle NOTICE Pressure Washer runs only while Trigger is squeezed When trigger is released Pressure Washer will turn OFF 2 Turn on the water supply c Remove the Tip Cleaner and rinse all debris away before re attaching it to the Extension O m M Tip Nozzle Extension Cleaner S giii Z Figure C 3 Turn on the Power Switch i p 9 Clean then store indoors out of children s reach ower Switch ON Page 12 For technical questions please call 1 888 866 5797 Item 69488 Opera
21. t Z 6 m Pump Assembly Parts List Part Description Qty 6 ValveCore 1 8 Jacket 1 i 9 O Ring 1 Page 16 For technical questions please call 1 888 866 5797 Parts Lists and Assembly Diagrams Part ___ Description _ 35 O Ring O 6 36 O Ring 6 37 ValeSeat tid 6 38 ValeCore 6 39 Vave 6 40 Valve Spring CEC 41 O Ring 6 i 42 VaveCap 6 Connecting Seat Gear Shaft 60 Bearing 1 Item 69488 Pump Assembly Diagram CO Hy NA Rama lt 9 Z 86 66 OV LY ct ev 77 97 97 27 97 67 OS LS 09 69 179 GG 99 49 95 6S MAINTENANCE Item 69488 For technical questions please call 1 888 866 5797 Page 17 m gt Z O m Pressure Washer Parts List and Assembly Diagram Part Description Qty 68 Right Motor Cover 1 88 CordClamp 1 98 Handie Extension 1 Bottom Housing Wheel Cover Axle Wheel Part Description Qty Gun Detergent Bottle 27a Note Gun extension and nozzle design may vary from those illustrated Page 18 For technical questions please call 1 888 866 5797 Item 69488 PLEASE READ THE FOLLOWING CAREFULLY THE MANUFACTURER AND OR DISTRIBUTOR HAS PROVIDED THE PARTS LIST AND ASSEMBLY DIAGRAM IN THIS MANUAL AS A REFERENCE TOOL ONLY N
22. ting Tips Become Familiar With your Machine 1 Before beginning work set aside enough time to familiarize yourself with this machine s cleaning rate and capacity along with all instructions and precautions contained in this section along with the Operating Instruction and Controls and Features sections 2 This unit is intended for various light to moderate cleaning applications If deeper cleaning is desired it can be attained at times however this is done at the expense of speed This unit is not intended for paint stripping or deep concrete cleaning applications 3 Clean a test area to satisfaction before 7 proceeding with the entire area as stated in Cleaning Recommendations 4 This unit has several settings and adjustments that effect the speed of cleaning and the water force applied to cleaning Good guidelines to keep in mind are WIDE STREAM QUICKER COVERAGE BUT LIGHTER CLEANING NARROW STREAM DEEPER CLEANING BUT 8 SLOWER COVERAGE Cleaning Recommendations 5 Clean an inconspicuous test area first Always begin with the fan spray at a distance of about 3 5 feet from the surface being cleaned to avoid damaging it Clear the test area of people and water sensitive objects If a pressure washing detergent is to be used apply the detergent 9 to this area as well After cleaning this area switch off the pressure washer and inspect the area carefully for any damage or discoloration If any
23. tions E 7 Warranty tc serials Ati Steins oe 20 Operation ser teats reat eee tee 10 wn gt TI m lt PACIFICHYDROSTAR WARNING SYMBOLS AND DEFINITIONS This is the safety alert symbol It is used to alert you to potential personal injury hazards Obey all safety messages that follow this symbol to avoid possible injury or death A DANGER Indicates a hazardous situation which if not avoided will result in death or serious injury AWARNING Indicates a hazardous situation which if not avoided could result in death or serious injury ACAUTION Indicates a hazardous situation which if not avoided could result in minor or moderate injury NOTICE CAUTION Addresses practices not related to personal injury Page 2 For technical questions please call 1 888 866 5797 Item 69488 IMPORTANT SAFETY INSTRUCTIONS A Safety Warnings always be followed including the following 1 Read all the instructions before using the product 11 2 To reduce the risk of injury close supervision is 12 necessary when a product is used near children 3 Know how to stop the product and bleed pressures quickly Be thoroughly familiar with the controls 13 4 Stay alert watch what you are doing 5 Do not operate the product when fatigued or under the influence of medication alcohol or drugs 6 Keep operating area clear of all persons an 7 Do not overreach or stand on unstable support Keep good footing an
24. ulated product two systems of insulation are provided instead of grounding No grounding means is provided on a double insulated product nor should a means for grounding be added to the product Servicing a double insulated product requires extreme care and knowledge of the system and should be done only by qualified service personnel Replacement parts for a double insulated product must be identical to the parts they replace A double insulated product is marked with the words DOUBLE INSULATION or DOUBLE INSULATED The symbol E may also be marked on the product Item 69488 For technical questions please call 1 888 866 5797 Page 5 wn gt m lt Symbology m WARNING marking concerning Risk of Eye Injury Wear ANSI approved safety goggles with side shields Read the manual before set up and or use WARNING marking concerning Risk of Electric Shock Properly connect power cord to appropriate outlet WARNING marking concerning Risk of Injection Do not direct spray at any person or animal A SAVE THESE INSTRUCTIONS PAGIFICHYDROSTAR Page 6 For technical questions please call 1 888 866 5797 Item 69488 Specifications 120VAC 60Hz 13A 1650 PSI 1 25 GPM 13 3 4 FT 35 ft Setup Before Use Read the ENTIRE IMPORTANT SAFETY INFORMATION section at the beginning of this manual including all text under subheadings therein before set up or use of this product AWARNING