1. X The marks from to in the figure are the parts numbers X The distance between the indoor unit and the floor should be more than 2m No 0010531057 Floor fixing dimensions of the outdoor unit Unit mm HSU 09H03 K F HSU 12H03 K F HSU 12C03 K F Selection of pipe For 09k For 12k To this unit both liquid and gas pipes shall be insulated Liquid pipe 6 35mm 1 4 6 35mm 1 4 as they become low temperature in operation Use optional parts for piping set or pipes covered with Gas pipe 9 52mm 3 8 12 7mm 1 2 equivalent insulation material 1 Fitting of the Mounting Plate and Positioning of the wall Hole When the mounting plate is first fixed 1 Carry out based on the neighboring pillars or lintels a proper leveling for the plate to be fixed against the wall then temporarily fasten the plate with one steel nail 2 Make sure once more the proper level of the plate by hanging a thread with a weight from the central top of the plate then fasten securely the plate with the attachment steel nail 3 Find the wall hole location A using a measuring tape 2 Making a Hole on the Wall and Fitting the Piping Hole Cover Outdoor side Wall hole Thickness Make a hole of 60 mm in diameter 66mm of wall slightly descending to outside
2. is used please attach it as figure Note Only for heat pump unit 3 Purging Method Push the air out of the indoor unit and piping as followes e Tighten the caps on the valves with specified torque po Tighten torque N m Valve rod Valve cap e When connecting pipe exceeds 5 meters 20g refrigerant shall be added per exceeding meter Charge according to the following list for 09k 12k Additional amount Indoor unit Oil trap Outdoor unit Indoor unit U Max Elevation B 5m CAUTION Max Length for9k A 7m In case more than 5 metres oil trap for 12k A 10m should be installed every 5 7m
3. the wall Install piping hole cover and seal it off with putty after installation Section of wall hole Piping hole pipe Indoor unit Connecting the indoor outdoor Electric Cable Removing the wiring cover Remove terminal cover at right bottom corner of indoor unit then take off wiring cover by removing its screws When connecting the cable after installing the indoor unit 1 Insert from outside the room cable into left side of the wall hole in which the pipe has already existed iw 2 Pull out the cable on the front side and connect the cable making a loop N When connecting the cable before installing the indoor unit D Insert the cable from the back side of the unit then pull it out on the front side Loosen the screws and insert the cable ends fully into terminal block then tighten the screws Pull the cable slightly to make sure the cables have been properly inserted and tightened After the cable connection never fail to fasten the connected cable with the wiring cover Note When connecting the cable confirm the terminal number of indoor and outdoor units carefully If wiring is not correct proper operation can not be carried out and will cause defect 1 If the supply cord is damaged it must be replaced by the manufacturer or its service agent or a similar qualified person The type of connecting wire is HO5 O7RN F or 245IEC57 YZW 2 If the fuse on PC board is broke
4. Installation Manual of Room Air Conditioner Read this manual before installation Explain sufficiently the operating means to the user according to this manual Necessary Tools for Installation 1 Driver 5 Torque wrench 17mm 22mm 26mm 9 Nipper 12 Reamer 2 Hacksaw 6 Pipe cutter 10 Gas leakage detector or 3 Hole core drill 7 Flaring tool soap and water solution 4 Spanner 17 19 and 26mm 8 Knife 11 Measuring tape Drawing for the installation of indoor and outdoor units Accessory parts Number Arrangement of piping directions Cushion 4 Rear left L Left 4 SS _ Rear ZL 1 2 right Pipe supporting plate mS n Right Below S Drain elbow 1 No Accessory parts ol articles Remote controller sek 1 Optional parts for piping os Mark Parts name R 03 dry battery 2 Non adhesive tape i iF Adhesive tape 1 Saddle L S with screws Connecting electric cable for indoor and outdoor 1 Drain hose Se Drain hose 7 7 Heating insulating material 4X50 Steel nail cement 6 Piping Hole eaves gt ae 4 L Plastic cap crew D Cover 1
5. n please change it with the type of T 3 15A 250V If the fuse of outdoor unit on PC board is broken please change it with the type of T 25A 250V 3 The wiring method should be in line with the local wiring standard 4 After installation the power plug should be easily reached 5 A breaker should be incorporated into fixed wiring The breaker should be all pole switch and the distance between its two contacts should be not less than 3mm Power cable aJa el lel 361 5mm i aiok gt 2X0 75mm H a ml le gt 3xX1 0mm2 j EEB Indoor unit Outdoor unit HSU 09H03 K F HSU 12H03 K F HSU 12C03 K F Outdoor unit Outdoor unit 1 Connection of pipes e To bend a pipe give the roundness as large as possible not to crush the pipe e Connecting the pipe of gas side first makes working easier e The max vertical distance between the indoor unit and the outdoor unit is 5 m Half union Flare nut Forced fastening without careful centering may damage the threads and cause a leakage of gas Spanner J Pipe Diameter Q Fastening torque Liquid side 6 35mm 1 4 18N m Torque wrench Gas side 9 52mm 3 8 40N m Gas side 12 7mm 1 2 55N m Be careful that matters such as wastes of sands etc shall not enter the pipe 2 Attaching Drain Elbow e f the drain elbow