Home

Haier HSU-09HEK03/R2(DB) User's Manual

image

Contents

1. 4 In cooling and dry using the air conditioner for a long time under the high air humidity condensate water may occur at the grille EUROPEAN REGULATIONS CONFORMITY FOR THE MODELS CE All the products are in conformity with the following European provision Low Voltage Directive 73 23 EEC Low Voltage Directive 2006 95 EC Electomagnetic Compatibility 89 336 EEC Electomagnetic CompatibilitY 2004 108 EC ROHS The products are fulfilled with the requirements in the directive 2002 95 EEC of the European parliament and of council on the Restriction of the use of Certain Hazardous Substances in Electrical and Electronic Equipment EU RoHS Directive WEEE In accordance with the directive 2002 96 CE of the European parliament herewith we inform the consumer about the dis posal requirements of the electrical and electronic products DISPOSAL REQUIREMENTS Your air conditioning product is marked with this symbol This means that electrical and electronic products shall not be mixed with unsorted household waste Do not try to dismantle the system yourself the dismantling of the air conditioning system treatment of the refrigerant of oil and of other part must be done by a qualified installer in accordance with relevant local and national legislation Air conditioners must be treated at a specialized treatment facility for reuse recycling and recovery By ensuring this product is disposed of correctly you will help to p
2. Contents OPERATION MAINTENANCE CAUTIONS HSU 09HEG03 R2 DB TROUBLE SHOOTING HSU 12HEG03 R2 DB HSU 18HEG03 R2 DB HSU 24HEG03 R2 DB HSU O9HEK 03 R2 DB HSU 12HEK03 R2 DB HSU 18HEK03 R2 DB HSU 24HEK03 R2 DB e Please read this operation manual before using the air conditioner Keep this operation manual for future reference 0010538410 PARTS AND FUNCTIONS 1 2 5 6 7 Parts and Functions E indoor Unit E Remote controller EK1 display board Oo 8 Additional functions display Supplemented HEALTH Powen Remote controller SJ w Ww AN A 9 QUIET button 10 HEAT button 11 COOL button 12 AUTO button 13 FAN SPEED button 14 TIMER button 15 HEALTH button 16 LOCK button B Used to lock buttons and LCD display 17 LIGHT button Control the lightening and extinguishing of the indoor LED display board 18 POWER ON OFF button 19 DRY button 20 TEMP button Operation mode QUITE SLEEP electrical heating Haier O EEn Ry E B _ m Sel 21 SWING button ram a 22 HOUR button HEALTH v EEIN o a a 23 EXTRA FUNCTION button i Oo o o Function Air sending Healthy Inlet Inlet grille airflow position1 Healthy airflow 3 Air Purifying Filter inside 4 Outlet lt gt position 2 Restore the original 1 Mod
3. Close doors and windows during operation Use the timer effectively During cooling operation prevent the penetration of direct sunlight with curtain or blind If the unit is not to be used for a long time turn off the power supply main switch E OFF c 1 Open the Inlet Grille Hold the front panel by the tabs on the both sides and lift it until it stops with a click 2 Detach the standard air filter Slide the knob slightly upward to release the filter then withdraw it 3 Attach Air Purifying Filter Put air purifying filter appliances into the right and left filter frames Remote Controller Indoor Body wipe the air conditioner by using a soft and dry cloth For serious stains use a neutral detergent diluted with water Wring the water out of the cloth before wiping then wipe off the detergent completely Do not usewater wipe the controller with a dry cloth Do not use glass cleaner or chemical cloth Do not use the following for cleaning Wei Gasoline benzine thinner or cleanser Hot water over 40 C 104 F may may damage the coating of the unit cause discoloring or deformation Air Filter cleaning 1 Open the inlet grille by pulling it upward 2 Remove the filter Push up the filter s center tab slightly until it is released from the stopper and remove the filter d
4. The machine is adaptive in following situation i During unit operation or at stop 1 Applicable ambient temperature range o a swishing or gurgling noise may Noise is heard be heard At first 2 3 minutes after unit start this noise is more noticeable Maximum D B W B 32 C 23 C This noise is generated by Indoor Minimum D B W B 21 C 15 C refrigerant flowing in the system Cooling e During unit operation a cracking Outd Maximum D B W B 43 C 26 C noise may be heard This noise is utaool Minimum D B 18 C generated by the casing expanding j o Normal or shrinking because of Indoor ee a Performance temperature changes Heatin wes inspection e Should there be a big noise from 9 Guidese Maximum D B W B 24 C 18 C air flow in unit operation air Minimum D B W B 7 C 8 C filter may be too dirty gt e This is because the system Outdoor Maximum D B W B 24 eng c Smells are circulates smells from the interior INVERTER Minimum D B 15 C generated air such as the smell of furniture aint cigarettes p 2 2 If the power supply cord is damaged it must be replaced by the Kor or eami are e During COOL or DRY operation manufacturer or its service agent or a similar qualified person indoor unit may blow out mist This is due to the sudden cooling 3 If the fuse of indoor unit on PC board is broken please change of indoor air it with the type of T 3 15A 250V If the fuse of outdoor unit is broken change it with the type of T 25A
5. a a 1 Unit start Press ON OFF on the remote controller unit starts 2 Select operation mode COOL button Cooling mode HEAT button Heating mode DRY button Dehumidify mode 3 Select temp setting Press TEMP TEMP button TEMP Every time the button is pressed temp setting increase 1 C if kept depressed it will increase rapidly TEMP Every time the button is pressed temp setting decrease 1 C if kept depressed it will decrease rapidly Select a desired temperature 4 Fan speed selection Press FAN button For each press fan speed changes as follows Remote controller Display EE EO E circulated LOW MED HI AUTO Air conditioner is running under displayed fan speed When FAN is set to AUTO the air conditioner automatically adjusts the fan speed according to room temperature Operation Remote Mode Controller Under the mode of auto operation air conditioner will automatically select Cool or Heat operation according to AUTO room temperature When FAN is set to AUTO the air conditioner automatically adjusts the fan speed according to room temperature In DRY mode when room temperature becomes lower than temp setting 2 C unit will run intermittently at LOW speed regardless of FAN setting In FAN operation mode the unit will not operate in COOL or HEAT mode but only in FAN mode AUTO is not available in FAN mode And temp setting is disabled In FAN mode sleep operation is not available
6. 250V In dry mode fan i sae ale pen oo The fuse is must be replaced by the manufacturer or its service speed can t be setting 2 C unit will run agent or a similar qualified person changed intermittently at LOW speed regardless of FAN setting 4 The wiring method should be in line with the local wiring standard The circuit breaker switch is ON but 5 The waste battery should be disposed properly e Is there a power failure A Is fuse blownout 6 This appliance is not intended for use by persons including e Is the air filter dirty children with reduced physical sensory or mental capabilities or Multipl Normally it should be cleaned lack of experience and knowledge unless they have been given USRR every 15 days supervision or instruction concerning use of appliance by a person check e Are there any obstacles before ible for their safet inlet and outlet y responsible for their safety e Is temperature set correctly e Are there some doors or 7 Children should be supervised to ensure that they do not play with windows left open the appliance e Is there any direct sunlight through the window during the 5 cooling operation Use curtain 8 In order to protect the units please turn off the A C first and at least e Are there too much heat sources 30 seconds later cutting off the power or too many people in the room during cooling operation
7. In HEAT mode warm air will blow out after a short HEAT period of the time due to cold draft prevention function When FAN is set to AUTO the air conditioner automatically adjusts the fan speed according to room temperature m B Mi Emergency operation and test operation Emergency Operation e Use this operation only when the remote controller is defective or lost and with function of emergency running air conditoner can run automatically for a while e When the emergency operation switch is pressed the Pi sound is heard once which means the start of this operation e When power switch is turning on for the first time and emergency operation starts the unit will run automatically in the following modes Room Designated Timer Fan temperature temperature mode speed Above 23 C emergency operation switch Le WD Below 23 C 23 C elt is impossible to change the settings of temp and fan speed It is also not possible to operate in timer or dry mode Test operation Test operation switch is the same as emergency switch Use this switch in the test operation when the room temperature is below 16 C do not use it in the normal operation e Continue to press the test operation switch for more than 5 seconds After you hear the Pi sound twice release your finger from the switch the cooling operation starts with the air flow speed Hi Sa Under this operation mode the fan mo
8. WARNING Please call Sales Service Shop for the Installation Do not attempt to install the air conditioner by yourself because improper works may cause electric shock fire water leakage A WARNING When abnormality such as burnt small found immediately stop the operation button and contact sales shop Ll Sy EY ore Connect power supply cord to the outlet completely 2 STRICT ENFORCEMENT Do not use power supply cord in a bundle Do not start or stop the operation by disconnecting the power supply cord and so on ENFORCEMENT Use an exclusive power source with a circuit breaker STRICT Use the proper voltage Check proper installation of the drainage securely STRICT ENFORCEMENT Sar 1 Do not use power supply cord extended or connected in halfway 2 Do not install in the place where there is any Q D 0 STRICT ENFORCEMENT Take care not to damage the power supply cord 9 PROHIBITION Wy ANN Do not channel the air flow directly Do not try to repair or at people especially at infants or the aged Af PROHIBITION Z CAUTION possibility of inflammable gas leakage around the unit 3 Do not get the unit exposed to vapor or oil steam PROHIBITION Do not insert objects into the air inlet or outlet S Do not use for the purpose of storage of food art work precise equipment breeding or cultivation o
9. starts SLEEP operation stops Approx 6hrs Temp setting Unit stop In COOL DRY mode Ne ee 2 In HEAT mode 1 hours after SLEEP mode starts temp will become 2 C lower than temp setting After another 1 hours temp decrease by 2 C futher After more another 3 hours temp rises by 1 C futher The unit will run for further 3 hours then stops Temp is lower than temp setting so that room temperature won t be too high for your sleep Temp setting Unit stop Decreases 2 C 3 hrs SLEEP SLEEP operation starts operation stops In HEAT mode 3 In AUTO mode The unit operaters in corresponding sleep mode adapted to the automatically selected operation mode 4 In FAN mode It has no SLEEP function 5 Set the wind speed change when sleeping If the wind speed is high or middle before setting for the sleep set for lowing the wind speed after sleeping If it is low wind no change Note When TIMER function is set the sleeping function can t be set up After the sleeping function is set up if user resets TIMER function the sleeping function will be cancelled the machine will be in the state of timing on HM POWER QUIET Operation 1 POWER Operation When you need rapid heating or cooling you can use this function EXTRA Press acon button to enter additional options when cycle display to 2A SA will flash and then press Kwe enter to power function When cancel the function please enter
10. time ON or OFF button will not flash any more 5 Cancel timer setting Press the timer button by times until the time display eliminated Hints After replacing batteries or a power failure happens time setting should be reset According to the Time setting sequence of TIMER ON or TIMER OFF either Start Stop or Stop Start can be achieved W Healthy airflow Operation 1 Press to starting Setting the comfort work conditions 2 The setting of healthy airflow function Press kso button to enter additional options Press this button continuously the louvers location will cycle between in the following three locations to choose the swing location what you needed and then press feaxet button to confirm Healthy Healthy gt N airflow gt ib airflow gt upwarder downwarder Present _ position 3 The cancel of the healthy airflow function Press uncnon button to enter additional options Press this button continuously the louvers location will cycle between in the following three locations again and then press Gye button to cancel E Notice Do not direct the flap by hand Otherwise the grille will run incorrectly If the grille is not run correctly stop for a minute and then start adjusting by remote controller Note 1 After setting the healthy airflow function the position grill is fixed 2 In heating it is better to select the gt mode 3 In cooling it is better to select the mode
11. additional options again and to cancel power function 2 QUIET Operation You can use this function when silence is needed for rest or reading Press QUIET button the remote controller will show sj and then achieve to the quiet function Press again this QUIET button the quiet function will be cancelled Note During POWER operation in rapid HEAT or COOL mode the room will show inhomogeneous temperature distribution Long period QUIET operation will cause effect of not too cool or not too warm Operation E Timer On Off On Off Operation 1 After unit starts select your desired operation mode 2 Press TIMER button to change TIMER mode Every time the button is pressed display changes as follows Remote controller ON gt OFF gt ON OFF gt ON lt OFF gt BLANK 0 5h 0 5h 0 5h TIMER ON OFF IMER ON TIMER OFF TIMER OFF ON Then select your desired TIMER mode TIMER ON or TIMER OFF or TIMER ON OFF on or orf will flash 3 Press W A button to set time A Press the button for each time setting time in the first 12 hours increased by 0 5 hour every time after 12 hours increased by 1 hour every time WV Press the button for each time settiing time in the first 12 hours decreased by 0 5 hour every time after 12 hours decreased by 1 hour every time It can be adjusted within 24 hours 4 Confirm timer setting After adjust the time press war button and confirm the
12. e display flap position Right amp left air airflow Horizontal flap Vertical blade Operation mode auTo cooL DRY HEAT FAN gt A B yard gt 10 and heating symbol adjust up and down air flow adjust left and right air flow displayed simultaneously gt Sleeping Don t adjust it manually z a Electrical heating Refresh air Display board Emergency Switch 2 Signal sending display reserved function Power gt 3 SWING display Fahrenheit Celsius mode conversion 4 FAN SPEED display 24 CANCEL CONFIRM button Display board Display Function Setting and cancel to the EKI eu ae atali we timer and other additional functions EK3 25 RESET button 5 LOCK display When the remote controller 6 TIMER OFF display appears abnormal use a sharp TIMER ON display pointed article to press this button 7 TEMP display to reset the remote Healthy function is not available for some units TIMER ON OFF display Signal receiver hole i TIMER ON OFF displa ON OFF display SLEEP dispeyy oP WE Loading of the battery 3 Ambient temp display Note to the power failure resume i When receiving the remote control Press the sleep button ten times in five seconds and enter function EIEE TESE ti after hearing four sounds And press the sleep button ten times aur E ea eine tte me within five seconds and leave this function after hearing two sounds temperature is displayed and this COOL HEAT DRY AUTO display room
13. ownward 3 Clean the filter Use a vacuum cleaner to remove dust or wash the filter with water After washing dry the filter completely in the shade 4 Attach the filter Attach the filter correctly so that the FRONT indication is facing to the front Make sure that the filter is completely fixed behind the stopper If the right and left filters are not attached correctly that may cause defects 5 Close the inlet grille 4 Attach the standard air filter Necessary installation ATTENTION The white side of the photocatalyst air purifying filter face outside and the black side face the unit The green side of the bacteria killing medium air purifying filter face outside and the white side face the unit 5 Close the Inlet Grille Close the Grille surely NOTE The photocatalyst air purifying filter will be solarized in fixed time In normal family it will be solarized every 6 months But it is not fit for washing by water and other scour The bacteria killing medium air purifying filter will be used for a long time no need for replacement But in the period of using them you should remove the dust frequently by using vacuum cleaner or flaping them lightly otherwise its performance will be affected e Please keep the bacteria killing medium air purifying filter in the cool and dry conditions avoid long time directly sunshine when you stop using it or its ability of sterilization will be reduced Cautions A
14. r other heating apparatus PROHIBITION Do not place animals or plants in the direct path of the air flow Her PROHIBITION Do not install the unit near a fireplace Take fresh air occasionally especially when gas appliance is running at the same time STRICT ENFORCEMENT Check good condition of the installation stand PROHIBITION Do not place any objects on or climb on the unit PROHIBITION Do not operate the switch with wet hand PROHIBITION Do not pour water onto the unit for cleaning A gt PROHIBITION Do not place flower vase or water containers on the top of the unit PROHIBITION Trouble shooting Cautions Before asking for service check the following N first e Do not obstruct or cover the ventilation grille of the air IFSt conditoner Do not put fingers or any other things into the inlet outlet and swing louver ia Phenomenon Cause or check points The system e When unit is stopped it won t restart e Do not allow children to play with the air conditioner In ne does not restart immediately until 3 minutes have case should children be allowed to sit on the outdoor unit immediately elapsed to protect the system ma e When the electric plug is pulled out Specifications and reinserted the protection circuit e The refrigerating circuit is leak proof will work for 3 minutes to protect the A air conditioner
15. revent potential negative cons equences for the environment and humen health Please contact the installer or local authority for more information Battery must be removed from the remote controller and dis posed of separately in accordance with relevant local and nation legislation IMPORTANT INFORMATION REGA RDING THE REFRIGERANT USED Contains fluorinated greenhouse gases covered by the Kyoto Protocol FUE This product contains fluorinated greenhouse gases covered by the Kyoto Protocol Do not vent into the atmosphere Refrigerant type R410A GWP value 1975 GWP global warming potential Please fill in with indelible ink e1 the factory refrigerant charge of the product e2 the additional refrigerant amount charged in the field and e 1 2 the total refrigerant charge on the refrigerant charge label supplied with the product The filled out label must be adhered in the proximity of the product charging port e g onto the inside of the stop value cover A contains fluorinated greenhouse gases covered by the Kyoto Protocol factory refrigerant charge of the product see unit name plate additional refrigerant amount charged in the field total refrigerant charge outdoor unit refrigerant cylinder and manifold for charging m MmOOW Maintenance For Smart Use of The Air Conditioner Do not block the air inlet or outlet Setting of proper room temperature Proper temperature ro r ip
16. temperature is only for reference Q RUNNING display 1 Remove the battery cover 2 Load the batteries as illustrated 2 R 03 batteries resetting key cylinder Be sure that the loading 4 is in line with the H Outdoor Unit ee Load the battery then put on the cover again The distance between the signal transmission head and the rece iver hole should be within 7m without any obstacle as well When electronic started type fluorescent lamp or change over type fluorescent lamp or wireless telephone is installed in the room the receiver is apt to be disturbed in receiving the signals so the distance to the indoor unit should be shorter Full display or unclear display during operation indicates the batteries have been used up Please change batteries f the remote controller can t run normally during operation please remove the batteries and reload several minutes later Hint Please be subject to the actual produce purchased the Remove the batteries in case won t be in use for a long period If above picture is just from your reference there is any display after taking out just press reset key Please be subject to the actual produce purchased the above picture is just from your reference OQ O E Q OUTLET CONNECTING PIPING AND ELECTRICAL WIRING inlet DRAIN HOSE Operation Mi Base Operation po OON w A Remote controller p S pue CooL HE RY
17. tor of indoor unit will run in high speed W Air Flow Direction Adjustment 1 Status display of air flow Pos 1 i Pos 2 Pos 3 IN Pos 4 Ko Pos 5 L Pos 6 N Auto swing cooling mode from pos 1 to pos 4 and pos 6 heating mode from pos 5 to pos 1 and pos 6 2 Left and right air flow adjustment manual Move the vertical blade by a knob on air conditioner to adjust left and right direction referring to Fig a C Cautions e When adjusting the flap by hand turn off the unit e When humidity is high condensate water might occur at air outlet if all vertical louvers are adjusted to left or right e It is advisable not to keep horizontal flap at downward position for a long time in COOLor DRY mode otherwise condensate water might occur Note When restart after remote turning off the remote controller will automatically memorize the previous set swing position Operation W Sleep Operation Press Function button to enter additional options when cycle display to will flash And then press xa enter to sleep function s Operation Mode 1 In COOL DRY mode 1 hour after SLEEP mode starts temp will become 1 C higher than temp setting After another 1 hours temp rises by 1 C futher The unit will run for further 6 hours then stops Temp is higher than temp setting so that room temperature won t be too low for your sleep SLEEP operation