1. Outdoor unit 1 Installation of Outdoor Unit Install according to Drawing for the installation of indoor and outdoor units 2 Connection of pipes e To bend a pipe give the roundness as large as possible not to crush the pipe e Connecting the pipe of gas side first makes working easier e The max vertical distance between the indoor unit and the outdoor unit is 5 m Half union Flare nut Forced fastening without careful centering c EO eum may damage the threads and cause a leakage of gas J Pipe Diameter Fastening torque Liquid side 6 35mm 1 4 18N m Gas side 9 52mm 3 8 Spanner CAS SIUE TA mm Torque wrench Be careful that matters such as wastes of sands etc shall not enter the pipe 3 Connection Use the same method on indoor unit Loosen the screws on terminal block and insert the plugs fully into terminal block then tighten the screws e Insert the cable according to terminal number in the same manner as the indoor unit e f wiring is not correct proper operation can not be carried out and controller may be damaged e Fix the cable with a clamp 4 Attaching Drain Elbow e f the drain elbow is used please attach it as figure Note Only for heat pump unit Outdoor unit 5 Purging Method Push the air out of the indoor unit and piping as followes 1 Remove the valve cap on 2 way valve in outdoor unit 2 Loosen by 1 2 turn the flare nut of gas pipe which is conn
2. side and connect the cable making a loop When connecting the cable before installing the indoor unit Insert the cable from the back side of the unit then pull it out on the front side Loosen the screws and insert the cable ends fully into terminal block then tighten the screws Pull the cable slightly to make sure the cables have been properly inserted and tightened After the cable connection never fail to fasten the connected cable with the wiring cover Note When connecting the cable confirm the terminal number of indoor and outdoor units carefully If wiring is not correct proper operation can not be carried out and will cause defect 1 If the supply cord is damaged it must be replaced by the manufacturer or its service agent or a similar qualified person The type of connecting wire is HO5 O7RN F or 245IEC57 YZW 2 If the fuse on PC board is broken please change it with the type of T 3 15A 250V 3 The wiring method should be in line with the local wiring standard 4 After installation the power plug should be easily reached 5 A breaker should be incorporated into fixed wiring The breaker should be all pole switch and the distance between its two contacts should be not less than 3mm 0000000 i W Outdoor unit Outdoor unit HSU 12HG13 B HSU 09HG13 B connecting wiring Power cable mod 09 12 L N 3G1 0mm2 mod 09 12 3G1 0mm 3 4 2X0 75mm Outdoor unit
3. 3 B HSU 12HG13 B Fixing of outdoor unit Fix the unit to concrete or block with bolts 010mm and nuts firmly and horizontally When fitting the unit to wall surface roof or rooftop fix a supporter surely with nails or wires in consideration of earthquake and strong wind If vibration may affect the house fix the unit by attaching a vibration proof mat Selection of Installation Place Place robust not causing vibration where the body can be supported Place which is less affected by rain or direct sunlight and is sufficiently sufficiently ventilated Place not affected by heat or steam generated in the vicinity where Place possible to bear the unit where vibration and noise are inlet and outlet of the unit are not disturbed not increased Place possible to drain easily where piping can be connected with the Place where discharged wind and noise do not cause a outdoor unit nuisance to the neighbors Place where cold air can be spread in a room entirely e Place where a distance marked lt gt is available as illustrated Place nearby a power receptacle with enough space around Refer in the above figure to drawings Place where the distance of more than Im from televisions radios wireless apparatuses and fluorescent lamps can be left In the case of fixing the remote controller on a wall place where the indoor unit can receive signals when the fluorescent lamps in the room are lightened Power S
4. Installation Manual of Room Air Conditioner Read this manual before installation Explain sufficiently the operating means to the user according to this manual Necessary Tools for Installation 1 Driver 5 Torque wrench 17mm 22mm 26mm 9 Nipper 12 Reamer 2 Hacksaw 6 Pipe cutter 10 Gas leakage detector or 3 Hole core drill 7 Flaring tool soap and water solution 4 Spanner 17 19 and 26mm 8 Knife 11 Measuring tape Drawing for the installation of indoor and outdoor units Accessory parts Number Accessory parts articles Remot troll l T D k R 03 dry battery 2 Non adhesive tape Adhesive tape h D 1 Saddle L S with screws ing plate Connecting electric cable for indoor and outdoor a 1 B Xo Drain hose a 4 H S han 19 Heating insulating material ji y 6 No a a CE ti J eae Piping hole cover Attention must be paid to tL the rising up of drain hose mM CEH 24X25 Plastic cap a Screw 1 5 Drain elbow a Arrangement of piping directions Cover 1 Rear left LL Left 4 Ss _ Rear i E right Cushion 4 KL Below A 1 Pipe supporting plate Connecting cable Note Cooling only units don t have Drain elbow D 1 ojoj o ojloj X The marks from Ato in the figure are the parts numbers X The distance between the indoor unit and the floor should be more than 2m No 0010518181 Floor fixing dimensions of the outdoor unit Unit mm HSU 09HG1
5. ate is first fixed for the position of wall hole 2 Making a Hole on the Wall and Fitting the Piping Hole Cover Make a hole of 60 mm in diameter Outdoor side slightly descending to outside the wall Wall hol o aol Thickness Install piping hole cover and seal it of wall off with putty after installation emai Section of wall hole Piping hole pipe 3 Installation of the Indoor Unit Drawing of pipe Rear piping e Draw pipes and the drain hose then fasten them with the adhesive tape Left Left rear piping e In case of left side piping cut away with a nipper the lid for left piping e In case of left rear piping bend the pipes according to the piping direction to the mark of hole for left rear piping which is marked on heat insulation materials Indoor unit 1 Insert the drain hose into the dent of heat insulation materials of indoor unit 2 Insert the indoor outdoor electric cable from backside of indoor unit and pull it out on the front side then connect them 3 Coat the flaring seal face with refrigerant oil and connect pipes Cover the connection part with heat insulation materials closely and make sure fixing with adhesive tape Heat insulation material Piping Lid for right piping Indoor outdoor fa electric cable Lid for under piping Fix with adhesive tape e indoor outdoor electric cable a
6. eted to 3 way valve 3 Loosen 2 way valve by 90 using hexagon wrench and after approx 10 sec tighten it up Gas comes out through flare nut on wide pipe If no gas is discharged tighten flare nut with specified torque 4 Open 2 way and 3 way valves using specified torque 5 Tighten the caps on the valves with specified torque ae Tighten torque N m Valve cap 20 25 2 way valve 6 35mm 1 4 3 way valve 29 52mm 3 8 o 212 7mm 1 2 HSU 09HG13 B HSU 12HG13 B e When connecting pipe exceeds 5 meters 20g refrigerant shall be added per exceeding meter Charge according to the following list for 9k 12k Additional amount 100g e Note When extending piping air inside piping shall be removed by using external refrigerant gas charge according to the following list Brand new outdoor unit is charged 50g more refrigerant than regulated weight Only for first installation this extra 50g can be used to purge air IN pipes During this procedure 50g refrigerant will be discharged in piping This must be strictly controlled within 90 and 10 sec 1 Power Source Installation e The power source must be exclusively used for air conditioner Over IOA e n the case of installing an air conditioner in a moist place please install an earth leakage breaker e For installation in other places use a circuit breaker as far as possible 2 Cutting and Flaring Work of Piping e Pipe cutti
7. nd drain hose must be bound with refrigerant piping by protecting tape Other direction piping e Cut away with a nipper the lid for piping according to the piping direction and then bend the pipe according to the position of wall hole When bending be careful not to crash pipes e Connect beforehand the indoor outdoor electric cable and then pull out the connected to the heat insulation of connecting part specially Fixing the indoor unit body e Hang surely the unit body onto the upper notches of the mounting plate Move the body from side to side to verify its secure fixing e In order to fix the body onto the mounting plate hold up the body aslant from the underside and then put it down perpendicularly mounting plate Unloading of indoor unit body ee mounting plate e When you unload the indoor unit please use your hand to arise the body to leave agraffe then lift the bottom of the body outward slightly and lift the unit aslant until it leaves the mounting plate agraffe indoor unit Connecting the indoor outdoor Electric Cable Removing the wiring cover Remove terminal cover at right bottom corner of indoor unit then take off wiring cover by removing its screws When connecting the cable after installing the indoor unit 1 Insert from outside the room cable into left side of the wall hole in which N the pipe has already existed 2 Pull out the cable on the front
8. ng is carried out with a pipe cutter and burs must be removed e After inserting the flare nut flaring work is carried out A Pipe diameter Size A mm Liquid side 6 35mm 1 4 0 8 1 5 Gas side 52 _ Flare tooling die 9 52mm 3 8 1 0 1 8 Gas side 12 7mm 1 2 12 20 Correct Incorrect y Lean Damage of flare Crack Partial Too outside 3 On Drainage Please install the drain hose so as to be downward slope without fail Please 7 do the Tf as Tl below tL It becomes high midway The end is immersed It waves The gap with the ground There is the bad smell in water is too small from a ditch e Please pour water in the drain pan of the indoor unit and confirm that drainage is carried out surely to outdoor e In case that the attached drain hose is in a room please apply heat insulation to it without fail Check for Installation and Test Run e Please kindly explain to our customers how to operate through the instruction manual Check Items for Test Run put check mark in boxes O Gas leak from pipe connecting O Is drainage securely carried out O Is the lamp normally lighting O Heat insulation of pipe connecting O Is the earth line securely O Are cooling and heating when O Are the connecting wirings of connected in heat pump performed normally indoor and outdoor firmly inserted CIs the indoor unit securely fixed O Is the operation of room temperature to the terminal block O Is p
9. ource Before inserting power plug into receptacle check the voltage without fail The power source is the same as the corresponding name plate Install an exclusive branch circuit of the power A receptacle shall be set up in a distance where the power cable can be reached Do not extend the cable by cutting it S11 10111010 me im o gt To this unit both liquid and gas pipes shall be insulated as they become low temperature in operation Use optional parts for piping set or pipes covered with equivalent insulation material Liquid pipe 6 35mm 1 4 6 35mm 1 4 Gas pipe 9 52mm 3 8 12 7mm 1 2 Indoor unit Indoor unit 1 Fitting of the Mounting Plate and Positioning of the wall Hole When the mounting plate is first fixed 1 Carry out based on the neighboring pillars or lintels a proper leveling for the plate to be fixed against the wall then temporarily fasten the plate with one steel nail 2 Make sure once more the proper level of the plate by hanging a thread with a weight from the central top of the plate then fasten securely the plate with the attachment steel nail 3 Find the wall hole location A using a measuring tape When the mounting plate is fixed side bar and lintel Fix to side bar and lintel a mounting bar Which is separately sold and then fasten the plate to the fixed mounting bar Refer to the previous article When the mounting pl
10. ower source voltage abided regulator normal O Is the connecting wiring of indoor by the code and outdoor firmly fixed O Is there any noise
Download Pdf Manuals
Related Search
Related Contents
Business Class M2 - Freightliner Trucks Samsung Електрически аспиратор за печка METRO-2Fan с два вентилатора (двоен вентилатор), 65 l Наръчник за потребителя D-Link DSL-2640R router Untitled - Strebel コンパクトクールオイルクーラーキット 取扱説明書 Weider WEEVSY2077 User's Manual camera sem fio 1.2g 208c Avers Solar 50/38 WI White Ice ETL PDF Copyright © All rights reserved.