Graham Field PATRIOT US0208PL User's Manual

image

Contents

1. Graham Field Brand bna el GL E MODEL 050208 050208 SEMI ELECTRIC BED MODEL 050458 USO458PL FULL ELECTRIC LOW BED USER MANUAL READ THIS MANUAL BEFORE OPERATING THE PATRIOT HOMECARE BED SAVE THIS MANUAL FOR FUTURE USE INFO THE MOST CURRENT VERSION OF THIS MANUAL CAN BE FOUND ONLINE www grahamfield com US0208 INS LAB RevD11 CONTENTS A SAFETY S mman aa 3 WARNING CAUTION NOTICE SUMMARY I 3 2 INTRODUCTION PATRIOT HOMECARE BED USER NANUAL aaa 4 THERMAL MOTOR PROTECTION sassa 4 GRAVITY DOWN FEATURE FOR HEAD AND KNEE ELEVATION I aaa 4 3 ASSEMBLY INSTR CTIONS n Su SER an 5 HEAD AND FOOT ASSEMBLY asidinin 5 MOTOR ASSEMBLY una uu 6 REMOVE MOTOR SLIDE 6 INS TALE MOTOR Sines ts ae ep 6 INSTALL MOTOR SLIDE 7 MOTOR ASSEMBLY TROUBLESHOOTING 7 FULL ELECTRIC BED ONLY 050458 US0458PL CASTER POSITION aaa 8 STANDARD CONVENTIONAL BED 24 4 14200441 1100
2. Patriot Homecare Bed 14 4 BED OPERATION Z WARNING Ensure that bed is secure and assembled as instructed on previous pages before operating Plug the power cord into any grounded outlet Z WARNING Do not leave the bed unattended when plugged in Info In the event of a power failure use a standard 9V battery to lower the bed s head and foot sections the 9V battery connection is attached to the motor When used with the battery the motor will only lower not lift the head and or foot sections PENDANT HAND CONTROL OPERATION Semi electric bed only 050208 USO208PL The semi electric pendant hand con trol is shown at right Use the pendant hand control to raise and lower bed head and foot Each button has a differ ent function as noted in the picture Full electric bed only 050458 USO458PL full electric pendant hand con trolis shown at right Use the pendant hand control to raise and lower bed head and foot Each button has a differ ent function as noted in the picture US0208 INS LAB RevD11 Patriot Homecare Bed to raise head to lower head and foot at the same time to lower head to raise foot to raise head and foot at the same time to lower foot Semi electric pendant hand control to lower head to lower foot to lower bed Full electric pendant hand control 15 CRANK OPERATION SEMI ELECTRIC BED ONLY 950208 USO208PL Use the crank at t
3. 8 LOW BED HEIGHT u aan an qi ai 8 BED END ASSEMBLY uu I a L u amana uh 9 ALL BED MODELS ASSEMBLE BED HEAD END aaa 9 ALL MODELS ASSEMBLE BED FOOT END 9 ALL MODELS INSTALL BED END LOCKING HARDWARE sssssssssssssssssssssssssssssssrseseeesetsuunsssssseseeeeeesuiusssssseteet 10 FULL ELECTRIC BED ONLY 050458 US0458PL ASSEMBLE HI LO MOTOR SHAFT TO FOOT END GEAR 12 HI LO ROD ASSEMBLY BED LENGTH csssssssssssssssssssesessusussssssseseeeesesusuuusssrssseseeeessuinssssseeeeeeeeseustuunsssseseseeeeeteumaneet 13 SEMI ELECTRIC BED ONLY 050208 USO208PL ASSEMBLE HI LO 13 FULL ELECTRIC BED ONLY US0458 USO458PL ASSEMBLE HI LO 13 ALL MODELS ATTACH HI LO ROD TO GEARBOX OR MOTOR SHAFT PINS aa a 14 4 suq 15 PENDANT HAND CONTROL OPERATION 15 SEMI ELECTRIC BED ONLY 050208 US0208PL 15 FULL ELECTRIC BED ONLY 050458 US0458PL I aaa 15 CRANK OPERATION SEMI ELECTRIC BED ONLY 050208 US0208PL u 16 TRENDELENBURG POSITION ALL MODELS aaa 16 REVERSE TRENDELENBURG POSITION ALL MODELS ccsssssssssssssssssusssssss
4. A WARNING If bed rails not properly installed and adjusted personal injury and or dam age to the bed rail could result For information on Bed Rail safety please see the following brochure A Guide to Bed Safety Bed Rails in Hospitals Nursing Homes and Home Health Care The Facts on the FDA website at www fda gov MedicalDevices ProductsandMedicalProcedures GeneralHospitalDevicesandSupplies HospitalBeds Z WARNING GF Health Products Inc assumes no responsibility for any damage or injury caused by improper installation of bed rails or unauthorized bed rail use Only Lumex bed rails are recommended for use with Patriot beds Please consult the instructions that ac company your Lumex bed rails for complete rail assembly and installation instructions LUMEX PATRIOT LIBERTY BED RAILS Lumex Patriot Liberty Bed Rails are designed specifically for use with Lumex Patriot Beds Devel oped using the FDA Hospital Bed System Dimensional Guidance to Reduce Entrapment and tested to the Hospital Bed Safety Workgroup and FDA Dimensional Test Methods for Bed System Zones 14 and International Standard IEC60601 2 58 Requirements for the Safety of Electrically Operated Hospital Beds Lumex Patriot Liberty Bed Rails offer added protection and reduce the risk of entrapment For installation of these FDA compliant bed rails follow the installa tion instructions that accompany them Patriot Liberty Bed Rail descriptions follow GF6500B 1 Assist
5. bed during operation A WARNING Do not allow this device to be operated by small children Z WARNING When operating the hi lo knee or back function of the bed ALWAYS ensure that the individual confined to the bed is positioned properly within the confines of the bed DO NOT let any extremities protrude over the side or between the bed rails when performing any functions A WARNING Ensure that body weight is evenly distributed over the surface of the bed Do not lie sit or lean in such a way that your entire body weight is placed only on the raised head or foot sections of the bed This includes when assisting the user in repositioning or transferring in or out of bed Z WARNING In order not to invalidate the warranty or create a hazardous condition resulting in serious personal injury GF Health Products Inc recommends the use of only Lumex replacement parts Z WARNING Before operating ensure that the bed frame rivets are properly seated in the bed end hooks otherwise personal injury or damage could result Z WARNING Keep all moving parts free of obstructions i e blankets sheets heating blan kets pads tubing wiring and other types of products Z WARNING Ensure that Bed End Locking Hardware is installed in order to prevent personal injury when moving the bed or using a bed mount trapeze A WARNING WARNING CAUTION labels applied to the bed outline hazards or unsafe prac tices that could result in personal injury and
6. bed only 950458 US0458PL Assemble hi lo rod Hillo rod assembly full electric bed spring button US0458 US0458PL inner tube outer tube inserted spring button position Depress spring button and insert inner tube into outer tube until first hole of second hole set is reached as shown above Release spring button to lock it into hole US0208 INS LAB RevD11 Patriot Homecare Bed 13 All models Attach hi lo rod to gearbox or motor shaft pins Both ends of the hi lo rod assembly have a slot to mount on the foot end motor shaft pins and bed end gearbox shaft pins Follow steps 2 3 to mount the hi lo rod assembly on the gearboxes notch at end of hi lo rod rests over pin at end of motor shaft FOOT END end of hi lo rod notch foot end gearbox end of hi lo motor shaft NN head end gearbox Fig 2 Full Electric Bed Fig 3 All Bed Models Attach hi lo rod assembly Fig 1 Semi Electric Bed to head end gearbox Attach hi lo rod assembly Attach hi lo rod assembly to foot end gearbox to foot end hi lo motor shaft 2 Connect the hi lo rod assembly to the bed Semi electric bed Attach either end of hi lo rod assembly to the foot end gearbox as shown in Fig 1 above Full electric bed Attach either end of hi lo rod assembly to the foot end hi lo motor shaft as shown in Fig 2 above 3 Attach other end of hi lo rod assembly to head end gearbox as shown in Fig 3 above US0208 INS LAB RevD11
7. other with motor cams up as shown above 2 Slide the head and foot sections together until the foot section s hook catches the head sec tion s rivet on both sides Ensure both rivets are completely seated before continuing head wing linkage plate Straighten sections Note Grid deck not shown for clarity 3 With the rivets fully seated in the hooks as described in step 2 rotate and straighten the bed as shown above Position head wing as shown above A NOTICE While balancing the frame do not elevate the knee too far or the linkage may over extend and lock If the linkage locks manually push the large linkage plate toward the foot of the bed US0208 INS LAB RevD11 Patriot Homecare Bed MOTOR ASSEMBLY 7 C O Z WARNING Assemble motor on bed as follows While it is possible to install the motor backwards avoid it Incorrect installation could cause Head the bed to move in unexpected ways Note that the motor ends are labeled and embossed with head and foot symbols shown at right Ensure that bed head and motor head and bed foot and motor foot are matched cc Foot Remove motor slide caps slide cap Remove motor slide caps 1 Remove the slide caps from both ends of the motor as shown above Plungers should be recessed in motor cavities if not plug the power cord into any grounded outlet and operate down func tion on the pendant hand control then unplug the power cord Inf
8. 55 Bed Length Low position Bed length Info To extend grid length 80 in to 84 in install optional kit 690 0084 000 all beds All models 87 0 inches Deck Width All models 36 0 inches Normal operating conditions 450 lb evenly distributed including mattress accessories rails etc Maximum patient weight 3501b Frame 0 ga 135 high strength low alloy steel roll formed Sleeping surface 1 ga 120 cold rolled steel 5 stage bath 1 S21F acid bath cleans grease and oil from metal 2 Fresh water rinse 3 QuiliPhos 20 phosphate coat inhibits rust and helps maintain electrical charge during powder application All parts are then coated with a colored epoxy powder and baked 35 minutes at 375 degrees F The powder coating finish is approximately 2 5 mils thick The coating is smooth uniform finish without runs wrinkles or grit US0208 INS LAB RevD11 Patriot Homecare Bed 17 6 ACCESSORIES BED RAILS Patriot Homecare Bed decks are equipped with patent pending slots specifically for bed rail instal lation providing a fixed place to mount GF bed rails Two styles of Lumex bed rails are described in Section 6 1 The Lumex Patriot Liberty bed rail system designed specifically for Patriot Beds and 2 Lumex Universal bed rails Please read the following bed rail safety information BED RAIL SAFETY
9. Bar The Assist Bar shown at right is a secure handhold and support for active patients who need assistance getting in and out of bed on their own This bar is bolted directly to either side of the bed frame to support the split frame when a patient enters or exits the bed It can also assist patients ca pable of grasping the bar and maneuvering GF6500B 1 themselves with rotating and turning in bed Assist Bar US0208 INS LAB RevD11 Patriot Homecare Bed 18 GF6580B 1 Quarter Rail head end slot foot pivot point pivot point At gt foot end pivot point slot i ad end foot end slot head end foot deck angle foot end deck GF6580B 1 angle Quarter Rail head end slots foot end slots The Quarter Rail shown above is approximately 18 inches in length when mounted on the Patriot bed It can be used as a head assist head rail or foot rail Mounting slot locations utilized when the Quarter Rail is used as a head rail are shown in head end slots above opposite slots are directly across bed Mounting slot locations utilized when the Quarter Rail is used as a foot rail are shown in foot end slots above opposite slots are directly across bed GF6590B 1 Half No Gap Head Rail head end slot pivot point slot slotted head deck angle mounting slots foot end GF6590B 1 x Half No Gap Head Rail The Half No Gap Head Rail shown above provides full head coverage of 31 5 inche
10. Bed extension kit 84 17 Bed height low full electric 8 Bed height standard full electric 8 Bed length adjustment 13 Bed operation 15 Bed rails 18 Bed rail safety 18 C Caster position full electric bed only 8 CAUTION statement significance 3 Crank operation semi electric bed only 16 D Deck height high position 17 Deck height low position 17 F Full electric 13 H Head and foot assembly instructions 5 Hi lo rod assembly 13 Info statement significance Introduction 3 L Lumex Patriot Liberty bed rails 18 Lumex universal bed rails 20 M Maintenance bed frame and sleeping surface 25 Maintenance cleaning 25 Maintenance electronics 25 Maintenance lubrication and mechanical 25 Maintenance and safety checks 25 Motor assembly 6 Motor assembly troubleshooting 7 Motor slide caps install 7 Motor slide caps remove 6 N NOTICE statement significance 3 US0208 INS LAB RevD11 Patriot Homecare Bed P Pendant hand control operation full electric 15 Pendant hand control operation semi electric 15 Power failure battery operation 15 s Service parts all models 22 Service parts bed components 22 Service parts bed end components 23 Specification construction 17 Specification weight 17 Specifications dimensions 17 T Thermal motor protection 4 Trendelenburg position 16 Trendelenburg position reverse 16 w WARNING statement significance 3 Warranty 26 27 U S A Corporat
11. LX5088 No Gap Bed Rail LX5088 No Gap Side Rail FOOTBOARD HEADBOARD Position spring loaded crossbraces B into slots G2 and G3 on both sides of bed with spring but tons facing inward as shown above US0208 INS LAB RevD11 Patriot Homecare Bed 20 GF6580A 1 Low Universal Half Rail Cable tie GF6580A 1 Low Universal Half Rail G Follow same m procedure ra for mounting lt half rails on foot end using I G3 slots FOOTBOARD Secure crossbrace to head deck angle with cable tie SUGGESTED RAIL TO HEADBOARD MINIMUM OF 9 25 Head end Position spring loaded crossbrace B into slots G2 on both sides of bed Position cross brace A so that the stabilizer rests underneath the head deck angle Secure the crossbrace to the head deck angle with a cable tie Ensure spring buttons face inward as shown above Info Suggested rail to headboard minimum is 9 25 inches Foot end Position spring loaded crossbrace B into slots G3 on both sides of bed Position cross brace A so that the stabilizer rests underneath the foot deck angle Secure the crossbrace to the foot deck angle with a cable tie Ensure spring buttons face inward as shown at head end above US0208 INS LAB RevD11 Patriot Homecare Bed 21 7 SERVICE PARTS ALL MODELS Service parts for all bed models are shown below and on the following two pages See pictures and tables for appropriate service parts Info To order
12. and pendant hand control semi electric 690 2001 411 Pendant hand control semi electric 690 3001 943 Motor and pendant hand control full electric 2 End locking hardware set of 4 not shown X Info US0208 and US0208PL are identified on the foot section component label as Patriot Semi Electric Bed Model H7920SE Info US0458 USO0458PL are identified on the foot section component label as Patriot Full Electric Bed Model H7920FE US0208 INS LAB RevD11 Patriot Homecare Bed 24 8 MAINTENANCE AND SAFETY CHECKS Perform the following as needed or between patient placements whichever happens sooner Electronics and Motors Bed frames and sleeping surface Lubrication and mechanical Check all controls to ensure that all functions work Foot control properly Head control Hi Lo if applicable Check all cables for damaged or frayed wires Power cord Pendant hand control cord Inspect motor slide caps for excessive wear and deformation Visually check all welds Inspect frames and sleeping surface for bending and excessive wear The metal parts of the bed are covered with a powder coating Clean all coated parts with mild detergent and warm water Periodically raise head and foot sections of the bed and remove dust from frame Also periodically remove mattress and clean mattress deck Lubricate all caster roller and swivel bearings with light machine oil Check all bolts and tighten as neede
13. d Z WARNING The bed s electronic system contains no serviceable parts Do not open the motors cables or pendant hand control Only an authorized equipment provider or factory trained personnel may perform service or adjustments on these components US0208 INS LAB RevD11 Patriot Homecare Bed 25 9 WARRANTY Health Products Inc warrants the Patriot US0208 050208 Semi Electric Homecare Bed Patriot US0458 US0458PL Full Electric Low Bed as follows Two year limited warranty for defects in workmanship and materials of mechanical components frame and electronics During the warranty period defective items will be repaired or replaced at manufacturer s option The warranty does not include any labor charges incurred in replacement part s installation or any associated freight or shipping charges to the manufacturer The warranties contained herein contain all the representations and warranties with respect to the subject matter of this document and supersede all prior negotiations agreements and under standings with respect thereto The recipient of this document hereby acknowledges and repre sents that it has not relied on any representation assertion guarantee warranty collateral con tract or other assurance except those set out in this document US0208 INS LAB RevD11 Patriot Homecare Bed 26 10 INDEX Assembly instructions 5 B Bed end assembly 9 Bed end locking hardware install 10
14. e Headquarters GF Health Products Inc Graham Field 2935 Northeast Parkway Atlanta Georgia 30360 telephone 770 368 4700 GRAHAM FIELD www grahamfield com
15. ed to shut down operation when overheated is a safety feature of this product Causes of thermal protection activation include multiple or repeated adjustment of long duration or the use of multiple functions at one time To ensure trouble free operation always allow a slight pause between multiple adjustments and avoid operating more than one function at a time If thermal protection activation occurs the bed pendant hand control will not function The thermal protection will reset after a period of time dependent on the severity of the overheating To short en the reset time temporarily unplug the power cord from the power outlet GRAVITY DOWN FEATURE FOR HEAD AND KNEE ELEVATION Patriot beds are equipped with a gravity down safety feature The motors push the head and knee grid decks up but do not pull the knee and head down As the motor plunger retracts the head and knee lower freely minimizing bed damage and or personal injury from items caught under the grid deck Info When using telescoping deck mount bed rails the head and knee may not lower without weight on the bed US0208 INS LAB RevD11 Patriot Homecare Bed 4 3 ASSEMBLY INSTRUCTIONS HEAD AND FOOT ASSEMBLY Assembly head and foot sections Note Grid deck not shown for clarity 1 Place the head and foot sections on their sides at approximately right angles to each
16. evating knee to elevate too high and bind linkage ous page US0208 INS LAB RevD11 Patriot Homecare Bed 7 FULL ELECTRIC BED ONLY 050458 USO458PL CASTER POSITION Any full electric Patriot bed can be used as either a standard height or low height bed by moving the casters fig 1 casters mounted at fig 2 casters mounted at low fig 3 casters mounted at low standard height height bed in lowest position height bed in elevated position Standard conventional bed height To achieve standard bed height insert casters into outside legs as shown in fig 1 above Low bed height To achieve low bed height insert casters into inner short legs as shown in figs 2 and 3 above When in the lowest position the casters are engaged for bed movement as shown in fig 2 above When elevated the bed is off the casters and cannot be moved as shown in fig 3 above Due to the clearances involved only minor travel and movement are recommended in the low po sition The casters can be moved to the outer legs to provide clearance if the bed must be moved or rolled US0208 INS LAB RevD11 Patriot Homecare Bed 8 BED END ASSEMBLY All bed models Assemble bed head end 1 Insert one locking and one non locking caster into bed end Locking casters must be installed diagonally from each other See previous page for full electric caster position options 2 Standing directly in front of the bed end position it as close to the bed as pos
17. he center foot of the semi electric bed shown at right to change bed height raise or lower entire deck Crank operation TRENDELENBURG POSITION ALL MODELS HEAD END AT LOWER ELEVATION THAN FOOT END 1 Lower bed to its lowest height Disengage the hi lo rod by compressing the spring button and removing the hi lo rod from the motor or bed end 2 Raise the foot bed end using the pendant hand control or crank semi electric bed only The head end will remain in the low position REVERSE TRENDELENBURG POSITION ALL MODELS HEAD END AT HIGHER ELEVATION THAN FOOT END 1 Raise bed to its highest height Disengage the hi lo rod by compressing the spring button and removing the hi lo rod from the motor or bed end 2 Lower the foot bed end using the pendant hand control or crank semi electric bed only The head end will remain in the high position US0208 INS LAB RevD11 Patriot Homecare Bed 16 5 SPECIFICATIONS ALL MODELS Specifications are subject to change without notice High position 5 Deck height High Position US0208 US0208PL US0458 US0458PL with cast US0458 US0458PL with 24 0 inches ers in low position 20 0 inches casters in standard position 23 5 inches ee lt r Deck height Low Position US0208 US0208PL US0458 US0458PL with cast US0458 US0458PL with 15 0 inches ers in low position 9 5 inches casters in standard position 13 inches
18. lth Products Inc is responsible for typographical errors Packaging warranties products and specifications are subject to change without notice Graham Field and Lumex are registered trademarks and Patriot is a trademark of GF Health Products Inc 2011 GF Health Products Inc US0208 INS LAB RevD11 Patriot Homecare Bed 2 1 SAFETY safety statements presented this chapter refer to the basic safety information that the erator of the Patriot Homecare Bed shall pay attention to and abide by There are additional safety statements in other chapters or sections which may be the same as or similar to the following or specific to the operations Please note the following special statements used throughout this manual and their significance Z WARNING Indicates a potential hazard situation or unsafe practice that if not avoided could result in death or serious personal injury A CAUTION Indicates a potential hazard situation or unsafe practice that if not avoided could result in moderate or minor personal injury A NOTICE Indicates a potential hazard or unsafe practice that if not avoided could result in product or property damage Info Provides application recommendations or other useful information to ensure that you get the most from your product WARNING CAUTION NOTICE SUMMARY Z WARNING Keep hands and feet clear of all moving parts Z WARNING Do not allow small children on or near
19. o Motor comes from factory with pendant hand control plugged into motor 2 Install 9V backup battery not provided and slide into storage area Install Motors 3 Hold the bed securely positioned with motor cams up as shown above 4 Position the motor over both cams 5 Tap either end of the motor housing shown below with enough force to snap the motor as sembly into position on the cam 6 Repeat step 5 for other end of motor US0208 INS LAB RevD11 Patriot Homecare Bed 7 Position the caps as shown at right so that the grooves in the slide cap are aligned with grooves the motor slide cap Install motor slide caps pressure 8 Apply straight downward pressure to each end of the cap while sliding into the closed position 9 Repeat step 8 for the other cap 10 Ensure that all four corners of each slide cap are engaged Install motor slide caps A WARNING Ensure that the motor is assem bled on bed as instructed above before use Motor assembly troubleshooting Problems associated with improper motor installation are listed below with appropriate fix Probable cause Fix Head operates with knee control button Motor is installed backwards Remove motor and reverse it see previ knee operates with head control button ous page Knee lifting linkages bind against grid Motor is installed backwards enabling Remove motor and reverse it previ deck preventing knee deck from el
20. or property damage do not remove them Z WARNING Ensure that the power cord DOES NOT get tangled around the bed bed rails or legs during normal operation of the bed A WARNING Do not leave the bed unattended when plugged in A NOTICE The pendant hand control cord must be routed and secured properly to ensure that the cord does NOT become entangled and eventually severed during use A NOTICE When using nasal or masked type administering equipment oxygen or air tubing MUST be routed and secured properly to ensure that tubing does NOT become entangled and eventually severed during normal operation of bed US0208 INS LAB RevD11 Patriot Homecare Bed 3 2 INTRODUCTION USER MANUAL This manual contains assembly and maintenance instructions for your Model US0208 050208 Semi Electric and US0458 US0458PL Full Electric Low Patriot bed Read the entire manual care fully before using your bed and refer to it during use if you have questions THERMAL MOTOR PROTECTION This product is powered by a quiet efficient DC motor system When the bed is plugged into a power outlet the electrical transformer is always energized in a stand by condition The Okimat actuator casing may feel warm to the touch even when the bed is not being used this is a normal condition Thermal protection activation protection against overheating caused by excessive or extended periods of operation which causes the b
21. re Remove the hairpin clip from the end of the lanyard assembly as shown and set it aside 3 Align the cord end with the frame bracket top hole closest to the bed end Insert the cord end through the hole so that an equal amount of cord extends outside either side of the frame bracket hole as shown in b 4 The lanyard assembly will now hang loosely with the clevis pin and fender washer end on the outside as shown in c US0208 INS LAB RevD11 Patriot Homecare Bed 10 f 5 From the inside reattach the hairpin clip to the cord s looped end as shown in d This prevents the cord from slipping back through the frame bracket hole 6 From the outside insert lanyard clevis pin with washer into the small hole directly below the bed end bracket top hook so that the washer rests against the bracket as shown 7 From the inside insert the hairpin clip now attached to the cord into the clevis pin hole to secure as shown in f 8 Follow previous steps 1 7 for other bed end corners ensuring that all four corners are securely fastened and locked in place US0208 INS LAB RevD11 Patriot Homecare Bed 11 Full electric bed only 050458 USO458PL Assemble hillo motor shaft to foot end gear box FOOT hi lo motor END notches in hi lo motor shaft coupler slide over gear box shaft pin gear box hi lo motor shaft Attach hi lo motor shaft to foot end gear bo
22. s and extends to eliminate the gap between the head board and the end of the rail The GF6590B 1 mounted on the bed s head and the GF6580B 1 mounted on the bed s foot combine to create the Patriot split rail system Half No Gap Head Rail mounting slot locations are shown in mounting slots above opposite slots are directly across bed GF6570B 1 Full Length Rail head end slot head end pivot point GF6570B 1 Full Length Rail The Full Length rail shown above is a nominal telescoping full length rail that provides maximum length rail perimeter coverage Full Length Rail mounting slot locations are shown in mounting slots above opposite side slots are directly across bed US0208 INS LAB RevD11 Patriot Homecare Bed 19 UNIVERSAL BED RAILS If you install Lumex universal bed rails follow the installation instructions that accompany them the following instructions are provided to describe the differences between the installation of bed rail crossbraces on Patriot grid beds and spring beds Z WARNING Do not use the bed rails as handles for getting into or out of bed this could result in personal injury and damage to the bed rails GF6570A 1 Full Length Side Rail GF6570A 1 Full Length Side Rail FOOTBOARD HEADBOARD Position spring loaded crossbraces into slots 1 G4 on both sides of bed with spring but tons facing inward as shown above
23. service parts contact our Customer Service department at 800 365 2338 fax 920 929 8213 BED COMPONENTS Partnumber Description _ Semiclectric 50208 USO208PL US0458 US0458PL 690 7100 901 690 7105 902 Foot section semi electri includes motor o x 690 7104 902 Foot section ful electric includes motors J x 690 7001 000 semi electric 1141 x gt x 690 7601 000 End set semi electric plastic panels 690 7004 000 End set full electric walnut panels 690 7604 000 End set full electric plastic panels US0208 INS LAB RevD11 Patriot Homecare Bed 22 BED END COMPONENTS Part number Description Semi electric US0208 US0208PL US0458 690 701 901 X 690 7601 901 690 7004 901 90 7604 901 90 7001 902 X 690 7601 902 90 7004 902 690 7604 902 999 0301 904 100 6330 014 100 6330 016 100 420 012 554 2001 015 panel head foot semi electric walnut panels 690 5001 025 End panel head foot semi electric plastic panels 690 5004 015 End panel head foot full electric walnut panels 690 5004 025 End panel head foot full electric plastic panels 52001059 x sO 5004 06 8002001912 609207516 0003520 002001910 01000 10 US0458PL gt gt lt gt lt gt gt US0208 INS LAB RevD11 Patriot Homecare Bed 23 BED SERVICE PARTS 1 690 2001 913 Motor
24. sible 3 With one hand reach over end and lift up the bed bed head end frame head Attach bed head end 4 Tilt the bed end slightly back toward you as shown above Engage lower rivet Lower bed onto lock 5 Engage lower rivet slightly with corner lock and tilt end toward bed as shown at above left 6 Lower bed onto corner lock as shown at above right All models Assemble bed foot end After bed head end has been attached perform steps 1 6 in All models Assemble bed head end above to install the foot end US0208 INS LAB RevD11 Patriot Homecare Bed models Install bed end locking hardware 1 After bed head end has been attached install Bed End Locking Hardware to act as a latch for each corner Bed End Locking Hardware part number 690 1000 100 includes four lanyards each as sembled from a clevis pin hairpin clip fender washer and nylon cord as shown at right Bed Lanyard end locking hardware while not necessary for normal bed operation will prevent the bed ends from accidentally rolling off when mov ing or pushing the bed or while installing or using bed mount trapezes Z WARNING GF Health Products Inc recommends the use of Bed End Locking Hardware at all times with hole clip bed end frame bracket lanyard hairpin clip bed end removed bracket a b corner lock 2 Refer to accompanying illustrations while installing Bed End Locking Hardwa
25. ssseseesesstsnunsssssereeeeseeeusuunussosesseeeeeeeninnansst 16 F SPECIFICATIONS ALE MODELS kinino nenia enen i E 17 BE ACCESSORIES BED RAILS Q u 18 BED RAIL SAFETY RnR 18 LUMEX PATRIOT LIBERTY BED 18 5 18 GF6580B 1 QUARTER e 19 GF6590B 1 HALF NO GAP HEAD 19 GF6570B 1 FULL LENGTH RAIL asas 19 UNIVERSAL BED RAILS 20 GF6570A 1 FULL LENGTH SIDE RAIL 20 LX5088 NO GAP BED RAIL 20 GF6580A 1 LOW UNIVERSAL HALF RAIL aaa 21 7 SERVICE PARTS ALL MODELS 22 BED COMPONENTS 22 BEDEND COMPONENTS Pe ean ee ee 23 BED SERVICE PARTS uu a gu akana aaa nates eine 24 8 MAINTENANCE AND SAFETY CHECKS 25 WARRANTY ccc ieee Sentech teers ana uqaqa heh ree usa 26 10 INDEX u nA te 27 GF Hea
26. x You must first attach the coupler end of the motor shaft to the foot end gear box see above 1 Note the position of the hi lo motor plug on the Okimat actuator next to the pendant hand control plug plug the hi lo motor into the actuator routing the hi lo motor cord under the fixed base frame cross angle as shown below to ensure clearance with the hi lo drive shaft 2 Plug the power cord into any grounded outlet 3 Pull the motor shaft toward the foot end Using the hi lo function on your pendant hand con trol slowly turn the hi lo motor shaft until the coupler matches up with the gear box shaft pin as shown above 4 Slide the coupler until it rests completely on the pin You may need to manipulate the foot end slightly from side to side and or lift the hi lo motor itself for proper alignment 5 Unplug the power cord US0208 INS LAB RevD11 Patriot Homecare Bed 12 HI LO ROD ASSEMBLY BED LENGTH The hi lo rod assembly consists of an inner and outer tube with a spring button lock to keep them together 1 Assemble outer and inner tubes Semi electric bed only 050208 USO208PL Assemble hi lo rod Hi lo rod assembly semi electric bed 050208 US0208PL spring button inner tube outer tube inserted a spring button position Depress spring button and insert inner tube into outer tube until third hole is reached as shown above Release spring button to lock it into hole Full electric