Home

Graham Field LUMISCOPE 1147 User's Manual

image

Contents

1. to the product or any other conditions whatsoever that are beyond the control of GF Health Products Inc GF Health Products Inc shall not be responsible for any type of incidental consequential or special damage To obtain warranty service on your Lumiscope Blood Pressure Monitor please contact the Repair Department at 1 800 672 8293 There is a 15 fee for return shipping and handling Please make checks payable to GF Health Products Inc Upon receipt we will repair or replace as appropriate the Blood Pressure Monitor and return it to you This warranty does not include any labor charges incurred in replacement part s installation or any associated freight or shipping charges to GF Health Products Inc Warranty is solely through the Repair Department Service of this product by anyone other than the Repair Department voids warranty 15 GF Health Products Inc 2935 Northeast Parkway Atlanta Georgia 30360 telephone 800 347 5678 770 447 1609 fax 800 726 0601 678 291 3232 GRAHAM FIELD www grahamfield com December 2009 GF Health Products Inc Made in China
2. 7 Oscillometric Pressure 20 280 mmHg Pulse Rate 40 195 beats min Accuracy Pressure 3 mmHg Pulse Rate 5 Inflation Pump driven Semi conductor 2x AAA batteries 3 minutes after last operation 4 F to 140 F 10 to 95 RH 50 F to 104 F 30 to 85 RH 3 15 L x 3 35 W x 2 36 H or 80 x 85 x60 mm 140g batteries excluded Wrist circumference of 135 220mm Blood Pressure Monitor Instruction Manual Batteries Pressure Detection Power Supply Auto Power Off Storage Environment Operation Environment External Dimensions Net Weight Cuff Dimensions Package Contents Note Specifications are subject to modification without prior notice 14 Symbol on Display Average Values of 4 3 Delete Past Readings User can delete all the past readings stored in each User Page 1 Press the PAGE Y button to select the User Page you want to delete 2 Press and hold the A MEMO amp PAGE Y buttons simultaneously for 5 seconds Symbol of ALL EE will be displayed and all past readings stored in that User Page will be deleted 12 LIFETIME LIMITED WARRANTY GF Health Products Inc offers a lifetime limited warranty on defects in material and workmanship for this product except as noted below This product warranty does not cover damage caused by misuse or abuse the attachment of any unauthorized accessory alteration
3. SIZE 72 97MM LUMISCOPE For The Quality Of Life Advanced Wrist Blood Pressure Monitor Model 1147 Instruction Manual LUMISCOPE For The Quality Of Life Read these instructions before using your Blood Pressure Monitor Save these instructions for future reference 1147 INS LAB RevA09 SAFETY PRECAUTIONS e Babies young children or individuals who cannot express their consent are not suitable for blood pressure measurement e Individuals with serious arteriosclerosis are not suitable for blood pressure measurement e Blood pressure readings may fluctuate during pregnancy Pregnant women should consult their doctor before taking measurement e If there are unusual values please consult your doctor before taking medical action Handling batteries properly As soon as old batteries wear out replace them with new batteries Do not use old and new batteries together Align the polarities of batteries correctly When the unit will not be used for more than 3 months remove the batteries Otherwise batteries may leak and cause damage to the unit QUICK START GUIDE Avoid smoking eating or exercising for 30 minutes before taking a measurement Do not move or talk during measurement Measurement can be taken on either arm however if possible always take measurements on the left arm 1 Sit upright in a chair with your feet on the floor 2 Remo
4. ect 3 Press the AMEMO button to display the next sets of values for the user selected Past readings are displayed from the most recent to the oldest 4 This blood pressure monitor can store up to 99 sets of past readings for each user 4 x 99 11 TROUBLESHOOTING Symptom _ Possible Cause No display when Replace with new batteries you press the Power Start button Battery polarities Re align batteries in correct are Incorrect polarities Err P displays Failure to inflate Ensure the cuff is properly connected Err 1 displays Deflating too rapidly Movement during Do not move during measurement measurement Signal interference Remove interfering source e g mobile phones magnets Err 3 displays Incorrect results Measure again Err 2 displays Note If your problem cannot be solved by the above consult a GF Health Products Inc representative DO NOT disassemble the unit STORAGE amp MAINTENANCE e Keep away the unit from direct sunlight extreme temperatures humidity or moisture e Use a dry or slightly water dampened cloth to clean the unit e Do not use alcohol benzene thinner or other volatile liquids to clean the unit 13 e Do not wash the wrist cuff or expose it to liquid e Remove the batteries from the unit when it will not be used for more than 3 months SPECIFICATIONS Model No Measurement Method Measurement Range 114
5. f and take note of your measurement 3 P he ave b eon Veer eai 8 When Hour digit flashes press the AMEMO or PAGE Y 4 Place your arm on a table so that the results Bibel ee button to select Hour Press the AVG button to cuff wil be at the same level as your Note You can press the Q button to stop measurement at 4 Follow the same steps to set the Month Date Hour and heart ti Minute confirm any time l 5 6 7 8 SIZE 72 97MM 3 5 Heartbeat Readings Regular but Above Normal Heartbeat WHO Classification Color 4 2 View Average Readings IZI TIJ Besides Systolic and Diastolicvalues Ifthe monitor detects a pulse rate above aS A ee E ones oa Pulse will also be displayed after a 100 beats per minute during measurement ft cv ee a ies 2 y the stad Page is not what you want to view press the Di measurement the monitor will display the pulse value and h i PAGE button to select id fu symbol alternately Example 102 H1 Mild hypertension bt e 3 Press the AVG button to view different Average Values Pul Moderate hypertension Yellow 5 different Average Values are available MaS Severe hypertension Red Irregular Heartbeat This unit has a unique feature that alerts user of irregular heartbeat detection during measurement Note An irregular heartbeat is defined as a heartbeat rhythm that has a variation of more than 25 from the average rhythm detected during measure
6. ment If an irregular rhythm occurs twice or more during the same measurement the monitor will display the pulse value and IH symbol alternately Example 90 IH Note Please consult your doctor if irregular heartbeat occurs often Regular but Below Normal Heartbeat If the monitor detects a pulse rate below 58 beats per minute during measurement the monitor will display the pulse value and LO symbol alternately Example 58 LO 9 3 6 WHO Light Indicator This unit features a 6 color LED light indicator to display blood pressure level in accordance with the WHO World Health Organization classification mmHg Grade 3 hypertension severe Red 110 Grade 2 hypertension moderate g 105 Yellow 100 b5 Grade 1 hypertension mild 2 Purple g 90 E High normal Green A 85 Normal 80 Sky Blue Optimal Blue 120 130 140 150 160 170 180 mHg Systolic Pressure 10 WHO Light Indicator Example If your measurement reading is 122 75 the LED light will display the color in blue MEMORY FUNCTIONS After measurement the last set of measured values will be saved automatically after measurement when the unit is turned off by pressing button or by automatic power off after 3 minutes 4 1 View Past Readings 1 Press the a MEMO button to enter memory function 2 If the User Page is not what you want to view press the PAGEY button to sel
7. over if an error occurs Each alarm lasts 45 seconds or you can turn it off by pressing the Q button TAKING A MEASUREMENT Note Avoid smoking eating or exercising for 30 minutes before taking a measurement Donot move or talk during measurement Measurement can be taken on either arm however if possible always take measurements on the left arm Sitting Correctly 1 Relax 2 Sit upright in a chair with your feet on the floor 3 Remove thick or tight fitting clothing from the lower arm Do not roll up your sleeve if it is too tight 3 2 Applying the Wrist Cuff 1 Place your elbow on a table with the palm facing upward Wrap the wrist cuff around the left wrist as shown below 2 Pull on the end of the cuff until it wraps securely around your upper wrist Do not over tighten the cuff Allow 1 2 cm or 2 inch between the bottom of the cuff and your wrist joint 3 Make sure the cuff is at the same level as your heart 3 3 User Setting This unit allows a maximum of 4 users to store measurement records in different User Pages Press PAGEW button to switch between User Page 1 2 3 and 4 3 4 Taking A Measurement 1 Press the button The cuff will automatically inflate and the measurement will start 2 When the measurement is complete the cuff will automatically deflate and your systolic and diastolic pressure values and pulse rate will display 3 Remove the wrist cuf
8. over will click into place when completely closed 2 2 Setting the Date and Time Note Set the correct date and time before taking a measurement Reset the date and time after replacing the batteries 1 Press and hold the AvG button for a few seconds until the Year display flashes 2 Press the amp AMEMO or PAGE Y button to select the current year 5 ON and OFF will then flash This is to have the clock display when the unit is not in use you can choose Clock Function ON or OFF Press AMEMO or PAGEY button to select Press the AVG button to confirm Note If you select Clock Function ON you will continue at the Alarm Setting section Otherwise setting will end 2 3 Setting the Alarm Note You will not be able to set alarm clock if Clock Function is set to OFF You can set a maximum of 4 alarms 6 To disable Alarm Press the A MEMO or PAGEY button to select OFF and press the AVG button to confirm 7 To set 1st Alarm Press the amp MEMO or PAGE Y button to select ON Press the AVG button to confirm 9 When Minute digit flashes press the AMEMO or PAGE Y button to select Minute Press the AVG button to confirm 10 Follow the same steps to set the 2nd 3rd and 4th Alarm Note Press the Q button anytime during clock setting alarm setting to start
9. ve tight fitting or thick clothing from the lower arm 3 Pull on the end of the cuff until it wraps securely around your wrist Place your arm on a table so that the cuff will be at the same level as your heart 4 Press the button The cuff will automatically inflate and the measurement will start 5 When the measurement is complete the cuff will automatically deflate and your systolic and diastolic pressure values and pulse rate will display OVERVIEW Monitor Date amp Time User 1 4 Memory Average Memory Systolic gt Sa ee Low Battery Diastolic Indicator Pulse Symbol Power Start Memory Recall at Up WHO Light Indicator Average Values Set Page Select Down Memory No 1 99 readings Features e One Touch Operation e Irregular Heartbeat Detector e Blood Pressure Mode and Clock Mode e 4 User 396 Total Memory 4 Alarm Clock Settings e 5 Mode Averaging Function Hour Day Week Month and Overall e WHO Blood Pressure Indicator with 6 Color LED e Auto off Power Saving Feature e Operated by 2 AAA batteries 4 PREPARATION Note Replace batteries when the battery indicator shows low voltage 2 1 Battery Installation 1 Remove the battery cover in the direction indicated on the cover 2 Insert 2 AAA batteries with the polarities as indicated 3 Slide the battery cover back to close it The c