Home

Graco Trabon MX Series-Flo Dividers User's Manual

image

Contents

1. He 5 556 4 MTG HOLES TUBE INLET 0 531 2080 13 487 2 750 02779 967 La 69 85 39 67 1 4 N P T F 2 375 PENE 1 375 INDICATOR 60 31 TL ea OUTLET 4 47 62 1 7 83 INLET arsa fi M M SECTION Pee 1 703 VANN 43 26 i HP ALY 1 140 TYP AZS 28 9 HA r TS capacny G27 K ran SECTION 12 7 1 4 N P T F pi N LUBE OUTLET Wi 2062 W wo ae 62 37 TORQUE SECTION l LT Weenie END PLUG F 5 562 LB TORQUE 48 2 FT LB 5 za 0 265 TIE ROD NUT 151 27 1 468 6 75 TORQUE 23 FT LB 37 28 Note Millimeter dimensions appear in parentheses below decimal figure in inches Noorsoo atm eam O foom o a Semra Soroa rro eo femena omea fros ORDERING INFORMATION MX P INSTALLATION OF PERFORMANCE INDICATORS IN ALL WORKING OUTLETS NUMBER OF SECTIONS 06 SIX 07 SEVEN 08 EIGHT 03 THREE 04 FOUR 05 FIVE 09 NINE 10 TEN VALVE CAPACITY 025 025 cu in SEE NOTE 8 100 100 cu in 050 050 cu in 125 125 cu in 075 075 cu in 150 150 cu in TYPE OF VALVE BLOCK T TWIN S SINGLE RH OUTLET L SINGLE LH OUTLET B TWIN W CYCLE PIN RIGHT SIDE C SINGLE W CYCLE PIN RIGHT SIDE RH OUTLET D SINGLE W CYCLE PIN RIGHT SIDE LH OUTLET H TWIN W CYCLE PIN LEFT SIDE J SINGLE W CYCLE PIN LEFT SIDE RH OUTLET K SINGLE W CYCLE PIN LEFT SIDE LH OUTLET t CROSSPORTING OPTION CR RIGHT HAND SIDE CL LEFT HAND
2. Proximity Switch are not available on 0 025 capacity Note Date codes K95 and earlier use gasket type seals Date codes Secuan ee 7 AQ6 and earlier late use o ring seals Verify type of seal used before 9 Indicate crossport option after capacity section if required omit if not KRS 3 required ordering a new or replacement proximity switch 9 P P ty 10 Divider systems should be limited to first and second stages only Third staging is not recommended Refer to Trabon bulletins L20101 L20105 and L20115 for further information on system design 11 For information on the modular version MXP having the same output capacities refer to Trabon bulletin L10132 All written and visual data contained in this document are based on the latest product information available at the time of publication Graco reserves the right to make changes at any time without notice Contact us today To receive product information or talk with a Graco representative call 800 533 9655 or visit us online at www graco com 2006 2009 Graco Inc Form No L10131 Rev B 1 09 Printed in U S A All other brand names or marks are used for identification purposes and are trademarks of their respective owners All written and x ej Jatei a visual data contained in this document are based on the latest product information available at the time of publication Graco reserves the right to make changes at any time without notice
3. SIDE CB BOTH SIDES OMIT WHEN NOT REQUIRED Divider Assembly Sketch Example PLUGGED 50S T e feme femea omnem sgccrersuneanson mr PEN t oren fio Divider With Indicator PLUGGED 255CR 1 PLUGGED OPEN 100T OPEN END COMPONENT ORDERING NOTES Description Part No Old Part No 1 Capacity sections are specified starting from inlet section and must equal Cycle Switch SPDT amp Bracket 563272 510 599 000 number of sections specified A BIT 2 When a capacity section is crossported its outlet is plugged and output is Cycle Switch DPDT amp Bracket 964357 510 577 000 diverted to the next section farthest from the inlet Singling Bars 562916 189 000 060 3 Last capacity section farthest from the inlet cannot be crossported Crossporting Bars 562917 189 000 090 4 Singled capacity sections can be crossported on one side only Divider Installation A F See Lit No L15126 5 When capacity section is singled the outlet not being used is plugged IGET NStaaton ACCESSONES CRARO 6 Internal crossporting can be supplied on a capacity section only when Performance Indicators See Lit No L15401 supplied on a manifold assembly if supplied as a loose unit it can be field a ar drilled only Proximity Switch See Lit No L15600 7 External singling and crossporting bars are available for field installation Accessories amp Parts See Lit No L10161 8 Cycle Indicator Pin and
4. Trabon MX Series Flo Dividers DESCRIPTION Trabon MX Series Flo Divider Valves are designed for heavy service and are ideal for large steel mill systems and similar applications For modular version MXP having the same output Capacities see bulletin 10132 A typical MX Series Flo Divider Valve Assembly to the right consists of an inlet section end section and three to ten valve sections The basic divider assembly will serve between three and twenty lube points The MX valve sections which have built in outlet check valves are available in various output per piston cycle sizes see specifications Each twin T section has 2 outlets one from each side of the section Each single S section has 1 outlet on either side but one outlet must be plugged to operate properly For applications with continuous oil lubrication Meter Flo the built in outlet check valves may be removed FEATURES ADVANTAGES e Delivers metered amount of lubricant e Economical and compact design e Lubricant outlets easily added or removed e Simple to install on new or existing machines e Built in outlet check valves e Hone fitted metering pistons OPERATION Operational sequence of an MX Series Flo Divider Valve Assembly is defined as progressive The term progressive means that each valve section completes its piston stroke discharging a measured amount of lubricant to the bearing it serves before the following valve sectio
5. n operates As long as lubricant is supplied under pressure to the inlet section of the divider assembly valve sections will continue to operate in a progressive manner Divider assemblies always follow a constant discharge pattern Whenever lubricant flow ceases the valving pistons will stop When flow resumes it will start again at the same point in the discharge cycle SPECIFICATION pressure a Max Operating Temperature Max Cycle Rate w Cycle Pin MX w o Cycle Pin Net Weight Divider Valve Assembly approx 3 Section Divider 21 Ibs 6 02 9 69 kg 25 Ibs 10 oz 11 62 kg 29 Ibs 14 oz 13 55 kg 34 Ibs 2 02 15 47 kg 38 Ibs 6 oz 17 40 kg 42 Ibs 12 oz 19 39 kg 47 Ibs 2 oz 21 37 kg 51 Ibs 8 oz 23 26 kg 4 Section Divider 5 Section Divider 6 Section Divider 7 Section Divider 8 Section Divider 9 Section Divider 10 Section Divider Torque Tie Rod Nut 23 ft Ibs Enclosure Plug 48 ft Ibs Outlet Port Plug 18 ft lbs sess omn o asw S o o fos tana mooo i o C tar This number is stamped on each valve section This is the volume discharge per outlet after one complete cycle PROVEN QUALITY LEADING TECHNOLOGY 2 515 6 375 DIMENSIONS 63 881 ro 0 500 DIA Inches mm ries 2 125 er SLE 0 218 EXTENDED 21 64 DIA 3 8 N P T F

Download Pdf Manuals

image

Related Search

Related Contents

- Creations  Smeg ER12150NL Instruction Manual  ZISE_30A_IMM CONVERT.qxd  Kenroy Home 32703ORB Installation Guide  EMC VSPEX BLUE-Anwender-Computing mit VMware  取扱説明書 PDF  User Manual  3M Jupiter brugsanvisning  NI ISM-7413 User Manual  m. philippe beauge, 06 64 95 42 63, philippebeau  

Copyright © All rights reserved.
Failed to retrieve file