Home
Goodman Mfg . Co. LP. Air Conditioner Air Handler with Painted Cabinet User's Manual
Contents
1. A Heat kit requires three phase power supply SincLE Point Kir Must be installed along with any of the above compatible heat kits This kit will fit any ARPF air handler as long as a compatible heat kit is installed in the unit 1 2 3 X X KX KX KX xX Xx lt xK KX KX KX X Xx gt lt gt lt Air handler must either be on medium or high speed Air handler must be on high speed For static pressure of 0 6 or higher air handler must be on medium or high speed 6 www goodmanmfg com SS GARPF QOOOOOOOO ONE 1 ELEMENT ROWS O QOQOOQOQOOOOCE L1 L2 L1 L2 PRODUCT SPECIFICATIONS THREE 3 ELEMENT ROWS O es ete es FOUR 4 ELEMENT ROWS NOTE WHEN INSTALLING HEATER KIT ENSURE SPEED TAP DOES NOT EXCEED MINIMUM BLOWER SPEED MBS SPECIFIED FOR THE AIRHANDLER HEATER KIT COMBINATION ON THIS UNIT S S amp R PLATE AFTER INSTALLING OPTIONAL HEAT KIT MARK A X IN THE O PROVIDED ABOVE MARK ACCORDING TO NUMBER OF HEATER ELEMENT ROWS INSTALLED NO MARK INDICATES NO HEAT KIT INSTALLED SEE NOTE 2 ll b d Wh TERMINAL BLOCK SHOWN FOR 50HZ MODELS ONLY SEE NOTE 5 COPPER POWER SUPPLY SEE RATING PLATE USE MIN 75 C FIELD WIRE THREE SPEED MOTOR WIRING SELECT MODELS ONLY SEE NOTE 3 COM RD LOW M2 BL MEDIUM M1 BK gt HIGH TR 1 IF REPLACEMENT OF THE ORIGINAL WIRES SUPPLIED WITH THIS ASSEMBLY IS NECESSARY USE WIRE THAT CONFORMS TO THE NATIONAL ELE
2. EC SERVICE VALVE A O A E 364216 374316 486016 496116 NOMINAL RATINSS SS CET E 10 10 10 pwidth E E FCT te E Service VANE S ELECTRICAL DATA Le i SS GARPF www goodmanmfg com 3 PRODUCT SPECIFICATIONS DIMENSIONS D Tr 1 2 54 cm gt C lt q 2 54 cm PLASTIC BREAKER COVER LOGO LOCATION SUCTION LIQUID y 1 447 7 039 3 7 cm 1 125 17 9 cm 2 9 cm 5 039 i 12 8 cm RIGHT SIDE VIEW FRONT VIEW mma eee er ae oe we er ae we ar bass aoe ae ane awe ao aoe are ae ame www goodmanmfg com SS GARPF PRODUCT SPECIFICATIONS Airrtow DATA CFM DELIVERED AGAINST EXTERNAL STATIC PRESSURE ARPF182416 ARPF193116 ARPF303016 ARPF363616 ARPF364216 ARPF374316 ARPF486016 ARPF496116 Note Assumes dry coil with filter in place SCFM correction for wet coil 4 208V 240V SS GARPF www goodmanmfg com 5 PRODUCT SPECIFICATIONS Heat Kit Matcu Ups 182416 193116 303016 363616 364216 374316 486016 496116 HKR 05 HKR OSCE x xT x xp xx x x eos A px px xxx 4 x HKR 08 HKR 08CE xt Y eo fx px px x x x i HKR 10 HKR toc e 1 e e xx x x x esco e eo eo e e e xx ezo pep e pep xy x eze pe poo pepe px px saas o pe peo peo ep xy x pmeazor Y fe poo pe pep xx i Revision level that may or may not be designated C Circuit breaker option
3. CTRIC CODE Wiring is subject to change Always refer to the wiring diagram or the unit for the most up to date wiring ZN Warwine SS GARPF EQUIPMENT GROUND USE COPPER WIRE High Voltage Disconnect EBTDR o RD BK BLACK GR GREEN RD RED PU_ PURPLE YL YELLOW BR_BROWN BL BLUE WHZWHITE FACTORY WIRING HIGH VOLTAGE LOW VOLTAGE FIELD WIRING HIGH VOLTAGE LOW VOLTAGE TR TRANSFORMER PLF_ FEMALE PLUG CONNECTOR PLM MALE PLUG CONNECTOR FL FUSE LINK Tlo THERMAL LIMIT HTR HEAT ELEMENTS EM__ RC SR EVAPORATOR MOTOR RUN CAPACITOR STRAIN RELIEF RELAY ELECTRONIC BLOWER TIME DELAY RELAY R EBTDR 1 RED WIRES TO BE ON TRANSFERMER TERMINAL 3 FOR 240 VOLTS AND ON TERMINAL 2 FOR 208 VOLTS 2 SEE COMPOSITE WIRING DIAGRAMS IN INSTALLATION INSTRUCTIONS FOR PROPER LOW VOLTAGE WIRING CONNECTIONS 3 CONFIRM SPEED TAP SELECTED IS APPROPRIATE FOR APPLICATION IF SPEED TAP NEEDS TO BE CHANGED CONNECT APPROPRIATE MOTOR WIRE RED FOR LOW BLUE FOR MEDIUM AND BLACK FOR HIGH SPEED ON COM CONNECTION OF THE EBTDR INACTIVE MOTOR WIRES SHOULD BE CONNECTED TO M1 OR M2 ON EBTDR 4 BROWN AND WHITE WIRES ARE USED WITH HEAT KITS ONLY 5 EBTDR HAS A 7 SECOND ON DELAY WHEN G IS ENERGIZED AND A 65 SECOND OFF DELAY WHEN G IS DE ENERGIZED all power before servicing or installing this unit Multiple power sources may be present Failure to do so may cause property damage perso
4. EM AR WARRANTY ASIS us Complete warranty details available from your local dealer or at www goodmanmfg com To receive the 10 Year Parts Limited Warranty online registration must be completed within 60 days of installa ACCREDITED WN tion Online registration is not required in California or Qu bec BUSINESS SS GARPF www goodmanmfg com 5 11 Supersedes 1 11 PRODUCT SPECIFICATIONS NOMENCLATURE Brand Engineering A Single piece Major Minor Revisions Air Handler Not used for inventory management Unit Application Refrigerant Charge Ceiling Mount PSC Motor No Digit R 22 only Downflow PSC Motor 6 R 410A or R 22 Multi Position Variable Speed Motor Multi Position PSC Motor Electrical Multi Position EEM Motor 1 208 240 V 1 Phase 60 Hz Wall Mount PSC Motor Nominal Capacity Range 13 SEER Cabinet Finish Multi Position amp Downflow Applications U Unpainted 1729 1 to 2 Tons for Export Systems P Painted 1830 1 3 Tons N Uncased 3642 3 3 Tons Ceiling Mount amp Wall Mount Applications Expansion Device Nominal Cooling Capacity Electric Heat kW F Flowrater 1805 1 Tons Cooling 5 kW Electric Heat T Expansion Valve 2405 2 Tons Cooling 5 kW Electric Heat 3608 3 Tons Cooling 8 kW Electric Heat PRIDE Mia suede i Au aa AA www goodmanmfg com SS GARPF PRODUCT SPECIFICATIONS SPECIFICATIONS O O O O 182416 193116 303016 363616 NOMINAL RATINGS BLOWER TI EC CI E
5. Goodman Air Conditioning amp Heating Air HANDLER WITH PAINTED CABINET 1 To 5 Tons Mutti Position THREE SPEED Standard Features Goodman e Suitable for use with refrigerants R 410A and R 22 e Check flowrater expansion device e Direct drive multi speed motor e Transformer and blower time delay on all units e Copper tube aluminum fin coll e Complies with the Factory sealed Air Handling Credit with or without field installed filter kits as listed in the 2001 Florida Building Code Chapter 13 Section 610 2 A 2 1 e AHRI Certified e ETL Listed Cabinet Features e Fully insulated painted steel cabinet with attractive Architectural Gray finish e Built in coil has horizontal vertical and downflow drain pans with secondary drain connections e Built in filter rack for 1 filter filter not included e Power supply entry at top low voltage entry on top and both sides e Factory sealed to achieve 2 or less leakage rate with or without field installed filter kits at 1 0 water gauge external duct static pressure Contents Nomenclature lo cccccccccccccccscccccucccccuseccccusescceusescscuteccesenecceens 2 Produc SPCCIICALIONS cnscsscsaviwessateiveoetasecusescenemnsebabasesivertansons 3 DIMENSIONS inc 4 i Airflow Data occccccccccccccceccccusecccccseccecsececeusccscuseccccusescecersceeness 5 Heat Kit Match U DS rennene sourin 6 WINNE DIA OT AIM oa 7 ACCESSOTICS serrr 8 ed PA AR CERTPED
6. nal injury or death www goodmanmfg com PRODUCT SPECIFICATIONS ACCESSORIES EXPANSION Varve Kits FOR AiR CONDITIONING AND Heat Pump APPLICATIONS OUTDOOR UNIT DRAIN Pan INSULATION Kits DownFLow APPLICATIONS HORIZONTAL APPLICATIONS smal 52 smal 15 Medium 19 Medium 19 Note Each kit contains enough material to modify 20 coils FILTERS O A REQUIRED DECEO EE O a Dea INT a om nea O a Tasson mea a Goodman Manufacturing Company L P reserves the right to discontinue or change at any time specifications or designs without notice or without incurring obligations 2010 Goodman Manufacturing Company L P Houston Texas Printed in the USA 8 www goodmanmfg com SS GARPF