Home

Golden Technologies 18" - 24" & 30" User's Manual

image

Contents

1. BLACK ROCK SET SIZE FIREPLACE WIDTH DEPTH OPENING HEIGHT FRONT BACK 18 24 18 14 20 24 30 21 1 2 16 21 30 36 30 16 21 If a hood is not installed there must be only noncombustible material from the top of the fireplace opening to a height of 20 A combustible mantel or shelf must be at least 39 up from the opening Ifa hood is installed on the fireplace the clearance can be reduced to 7 3 BURNER SYSTEM INSTALLATION Before starting installation find out if local and state codes approve vent free gas logs If unvented gas logs are not approved the installation must be made with the fireplace damper partially open and locked to assure the minimum vent area required by local codes or the National Gas Fuel Code ANSI Z223 1 latest edition Use the damper clamp provided Clean the firebox thoroughly In the future frequent cleaning may be required due to excessive lint from carpeting and other materials All burner components must always be kept clean WARNING Before installing in a solid fuel burning fireplace the chimney flue and firebox must be cleaned of soot creosote ashes and loose paint by qualified chimney cleaner If a 1 2 gas supply line is not already installed in the fireplace a call to your plumber is recommended Check to make sure the gas supply is the same type natural or L P as listed on the rating plate attached to the burner Note the approved gas pressure chart Model GB TFII 24 30 M
2. VALVE FROM HOME FOR LONG PERIODS OF TIME Rocker Switch Pilot Sumer 110 u TT Ignitor Button Lo amp Flame Adjustment knob Control Knob TO TURN OFF GAS TO APPLIANCE MILLIVOLT VALVE CONT SHUTTING OFF HEATER 1 Turn control knob clockwise to the OFF position 2 Set rocker switch to OFF position Shutting off burners only pilot stays lit You may shut off burner and keep the pilot lit by doing one of the following 1 Turn control knob clockwise to the PILOT position 2 Set rocker switch to OFF position 3 Turn remote control to OFF position MANUAL LIGHTING PROCEDURE 1 Follow steps 1 through 6 under lighting instructions 2 Depress control knob and light pilot with match or lighter 3 Keep control knob press in for 30 seconds after lighting pilot After 30 seconds release control knob Now follow step 9 lighting instructions QLQY QD QA Sf EPPA SPP EP REAREY Wes KS SN CON BONG SSA BO SY BOD DN BHO VANNON OAN SZNS BS BHO BN UNO ANO CA DIO VG DA S DRS Ne LE LIMITED WARRANTY SZ SN Golden Blount Gas Logs are warranted against defective materials and or LS FE workmanship for as long as you own them Burner Assembly is guaranteed for five RK NW years from date of purchase ODS Pilot Assembly and valve are covered for one Sx SP year lt lt EE This warranty does not cover parts subjected to misuse abuse improper handling or SE lt S improper installation The GB warranty
3. INSTALLATION AND OPERATING INSTRUCTIONS FOR VENT FREE OR VENTED INSTALLATIONS GOLDEN BLOUNT TEXAS FLAME IT GAS LOGS NATURAL GAS OR L P 18 24 amp 30 SIZE SETS The Golden Blount vent free gas log sets comply with the National Safety Standards and are tested and design certified by CSA to ANSI Z21 11 2 2000 unvented heaters Z21 60a 2000 decorative gas appliances for installation only in a woodburning masonry or UL listed manufactured fireplace or in a Golden Blount or any other CSA approved vent free fireplace This product may be burned with the fireplace damper in either a closed or open position MANUFACTURED BY ben BS INC 4301 WESTGROVE DRIVE ADDISON TX 75001 Warning If the information in this manual is not followed exactly a fire or explosion may result causing property damage personal injury or loss of life e Do not store or use gasoline or other flammable vapors or liquids in the vicinity of this or any other appliance e What to do if you smell gas Do not try to light any appliance Do not touch any electrical switch do not use any phone in your building Immediately call your gas supplier from a neighbor s phone If you cannot reach your gas supplier call a fire department Installation and service must be performed by a qualified installer service agency or the gas supplier Warning Logs must be arranged so that the flames only touch bottom back lo
4. Push in control knob all the way and hold in While still holding the control Knob press in the ignitor pushbutton several times This will cause a spark at the pilot burner which will ignite the pilot flame Continue to hold the control knob in for about one 1 minute after the pilot is lit Release the knob and it will pop back out Pilot should remain lit If tt goes out repeat steps 1 5 If Knob does not pop out when released stop and immediately call your service technician or gas supplier If pilot does not stay lit after several tries turn the gas control knob to OFF and call your service technician or gas supplier 6 Turn the gas control knob counterclockwise to ON NOTE The gas control knob has two settings With the gas control knob all the way to the ON position the log is set on high and with the control knob approximately half way between PILOT and ON the unit is on low You can see the difference in the flame height TO TURN OFF GAS TO APPLIANCE Push in gas control knob slightly and turn clockwise to OFF Do not force IGNITOR PILOT BURNER GAS CONTROL KNOB IGNITOR LIGHTING INSTRUCTIONS MILLIVOLT VALVE 1 STOP Read the safety information previously listed above Make sure manual shutoff valve is fully open 2 3 Set rocker switch to OFF position 4 Press in and turn control knob clockwise gt to the OFF position Di Wait five 5 minutes to clear out any gas Then smell for gas inc
5. VICE PERSON in the diagnosis of problems and the corrective action to be taken SYMPTOM POSSIBLE CAUSES CORRECTIVE ACTION 1 Pilot will not light with Piezo ignitor 2 Pilot will not stay lit after following lighting instructions 3 No gas to main burner with pilot flame burning and valve turned to On position 4 Soot accumulating on logs 5 Both main burner and Pilot flame shuts off A Main shutoff valve closed B Air in the gas line C ODS Pilot orifice plugged not allowing gas to flow D No gas supply to the fireplace A Defective thermocouple B Thermocoupler fitting not tight in valve C Weak pilot flame D Defective valve A Plugged main burner orifice B Defective valve A Flame touching log surface A Insufficient oxygen to operate heater B Drafty conditions around burner assembly 11 1 Make sure that the shutoff valve located on the pipe supplying gas to the fireplace is open Light a match turn valve knob to PILOT position and depress Keep match near pilot burner assembly Replace the ODS Pilot assembly Check plumbing to see if gas line has been hooked up to gas supply Propane tank empty Replace thermocouple Carefully tighten fitting Pilot flame must engulf thermocouple Clean and or adjust pilot for maximum flame impingement on thermocouple Replace valve Carefully remove and clean orifice Replace valve R
6. ax Input 35 000btu hr Min Input 28 500btu hr Gas Inlet Pressure Maximum 10 5 IN wc 14 0 IN WC 10 5 IN WC 14 0 IN WC EONO Roma assi ae Regulator Pressure 3 5 IN WC 10 0 IN WC 3 5 IN WC 10 0 IN WC Manifold pressure check should be made with the appliance burning in the high setting A 1 8 NPT test plug is located on the regulator LP Installations require an external regulator in addition to the regulator installed in the burner system The LP tank could explode if the additional regulator is not installed When checking gas inlet pressure the appliance must be isolated from the gas supply line by closing its individual manual shut off valve during and pressure testing of the gas supply at test pressures equal to or less then 1 2 psig 3 5 KPA Centrally locate the burner grate unit inside the firebox Position burner grate unit towards rear of the firebox Connect the burner to the gas supply using the connector tube and brass elbow supplied in the kit Some installa tions may require different fittings that are available from hardware stores Turn on the gas with the burner valve in the OFF position and check all fittings for leaks using soapy water Do not use a flame to leak test PLACEMENT OF LOGS 18 SETS Front ember log sits under front ember burner tube as shown Bottom back log is to be placed on back of grate and against burner support brackets as illustrated Notches in bottom log
7. e to the floor WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electrical switch Do not use any phone in your building Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department C Use only your hand to push in or turn the gas control knob Never use tools If the knob will not push in or turn by hand do not try to repair it call a qualified service technician Force or attempted repair may result in a fire or explosion D Do not use this appliance if any part has been under water Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water LIGHTING INSTRUCTIONS 1 STOP Read the safety information previously listed above 2 Push in gas control knob slightly and turn clockwise to the OFF position NOTE Knob cannot be turned from PILOT to OFF unless knob is pushed slightly Do not force 3 Wait five 5 minutes to clear out any gas Then smell for gas including near the floor If you smell gas STOP follow B in the safety information listed above If you don t smell gas go to the next step 4 Find Pilot follow metal tube from gas control The pilot is located on the front side of burner in the center 5 Turn knob on gas control counterclockwise to the PILOT position
8. earrange the logs so that flames do not touch the logs at any point Open outside door or window slighily Eliminate draft
9. g or front ember log Flames must not touch any other log in set or any part of firebox This is an unvented gas fired heater It uses air oxygen from the room in which it is installed Provisions for adequate combustion and ventilation air must be provided IMPORTANT Read all instructions carefully before starting installation Failure to follow these instructions may result in property damage personal injury or possible loss of life SAFETY AND GENERAL INFORMATION e Use correct gas type for your appliance Do not convert from one gas type to another e f this appliance is for use with Propane gas do not place propane supply tank s inside any structure Locate propane supply tank s outdoors e Do not use the appliance for burning trash or cooking Never place matches paper garbage or any other material on top of logs or logs into flame e Always operate appliance with front fireplace screens closed e Make sure any safety wire mesh screen or guard removed for servicing is in place before running appliance e Never burn with glass doors closed e Never run appliance in small closed room Open door into next room to help ventilate e If appliance shuts off do not relight until you provide fresh outside air If appliance keeps shutting off have it serviced e Do not run appliance where flammable liquids or vapors are used or stored under dusty conditions e Surface of appliance becomes ver
10. luding near the floor If you smell gas STOP follow B in the safety information on page 7 If you don t smell gas go to the next step 6 Press in and turn control knob counterclockwise to the PILOT position Press in control knob for 5 seconds NOTE If lighting this unit for the first time after hooking up to gas supply the control knob may need to be pressed in for up to 30 seconds This will allow air to bleed from the gas system 7 With control knob pressed in press and release ignitor button This will light pilot The pilot is attached to the main burner If needed keep pressing ignitor button until pilot lights NOTE If pilot does not stay lit contact a qualified service person or gas supplier for repairs Until repairs are made light pilot with match see manual lighting procedure 8 Keep control knob pressed in for 30 seconds after lighting pilot After 30 seconds release control knob e If control knob does not pop out when released contact a qualified service person or gas supplier for repairs NOTE If pilot light goes out repeat steps 4 8 9 Slightly push in and turn control knob counterclockwise to the ON position 10 Wait one minute and switch rocker switch to the on position to light burner 11 Set flame adjustment knob to any level between HI and LO CAUTION DO NOT TRY TO ADJUST WARNING MAKE SURE THE ROCKER SWITCH FLAME HEIGHT BY USING THE MANUAL IS INTHE OFF POSITION WHEN YOU ARE AWAY SHUT OFF
11. o the fireplace Avoid any drafts that alter burner flame patterns e Solid fuels shall not be burned in a fireplace where an unvented room heater is installed CAUTION NOTE CARBON MONOXIDE POISONING MAY LEAD TO DEATH Early signs of carbon monoxide poisoning resemble the flu with headache dizziness and or nausea If you have these signs the heater may not be working properly Get fresh air at once Have heater serviced Some people pregnant women persons with heart or lung disease anemia those under the influence of alcohol those at high altitude are more affected by carbon monoxide than others WARNING ANY CHANGES TO THIS HEATER OR ITS CONTROLS CAN BE DANGEROUS AND CAN VOID WARRANTY Children and adults should be alerted to the hazards of high surface temperature and should stay away to avoid burns or clothing ignition Young children should be carefully supervised when they are in the same room as the appliance Note Installation and repair should be done by a qualified person well trained in the installation of such appliances You may need a building permit from your local Building Commissioner before installing this appliance Any safety screen or guard removed for servicing an appliance must be replaced prior to operating the heater Do not burn with glass doors in a closed position 24 amp 30 SETS 7 LOGS BURNER ASSEMBLY j ELBOW CLAMP GLOWING EMBERS fe so CONNECTOR TUBE F
12. red Remaining logs are to be placed in numbered notches as illustrated WARNING Failure to position the parts in accordance with these diagrams or failure to use only parts specifically approved with this heater may result in property damage or per sonal injury NOTE Logs must be arranged so that the flames only touch bottom back log or front ember log Flames must not touch any other log in set NOTE Flames must not touch any part of firebox housing Damper handle firebox roof etc After positioning the logs on the burner grate pour the black lava rock in front of the ember log and around the sides to enhance the ap pearance Spread the allotted amount of ember material over the ember pipe positioned in the front ember log NOTE Do not exceed the allotted amount of embers provided with the set EMBER BURNER TUBE EMBER LOG GLOWING EMBER MATERIAL FOR YOUR SAFETY READ BEFORE LIGHTING WARNING If you do not follow these instructions exactly a fire or explosion may result causing property damage personal injury or loss of life A This appliance is equipped with a push button piezo ignition device which automatically lights the pilot If the piezo fails to ignite the pilot then follow the lighting instructions for lighting the pilot with a match B BEFORE LIGHTING smell all around the appliance for gas Be sure to smell next to the floor because some gas is heavier than air and will settl
13. specifically excludes any liability for indirect lt FE incidental or consequential damage to property BY NG INA Defective logs or defective parts should be returned to your dealer or to the factory E DI i i SRI BOS prepaid with a copy of your sales receipt Defective parts will be repaired or replaced RK SL at the factory s option and returned to you prepaid ZO gt Zo RK HO E GOLDEN BLOUNT INC 4301 WESTGROVE DRIVE ADDISON TX 75001 gt INA NES LEVI QHODRE S UNT TUTAN SIOA S OTTIS QHODRY S UNT TUTAN ISTANTI X ANAOKOA AKAN ANASA DAKAN 9 PARTS LIST TO ORDER PARTS CALL OR WRITE GOLDEN BLOUNT INC 4301 WESTGROVE DR ADDISON TX 75001 972 250 3113 ITEM QUANTITY DESCRIPTION TF 1I 18 TOP LEFT LOG TF 1I 18 TOP RIGHT LOG TF II 18 BOTTOM BACK LOG TF II 18 BOTTOM FRONT LOG TF 1I 18 FRONT EMBER LOG TF II 24 380 MIDDLE LEFT LOG TF II 24 30 MIDDLE RIGHT LOG TF II 24 30 LEFT FRONT LOG TF II 24 80 RIGHT FRONT LOG TF 1I 24 30 BOTTOM BACK LOG SPECIFY SIZE CO CO N OO O1 B Go PO a e ook O 15 1 PIEZO IGNITOR L 00 GAS REGULATOR SPECIFY MODEL AND GAS TYPE 23 1 BLACK LAVA ROCK 26 1 PUSH BUTTON IGNITOR NOT SHOWN MILLIVOLT MODEL 10 TROUBLESHOOTING REFERENCE With Proper installation and maintenance your new Gas Appliance should provide years of trouble free service If you do experience a problem this guide will assist a CERTIFIED SER
14. ting e Turn off appliance and let cool before servicing Only a qualified service person should install service and repair appliance e Inspect the appliance before use and at least annually by a professional service person Frequent cleaning may be required due to excess lint from carpeting bedding material etc It is important that control compartment burner and circulating air passage of the appliance be kept open e Vhen operated for the first time there will be some smell from the appliance This will diminish and disappear after a few hours of operation e The National Gas Fuel Code defines a confined space as a space whose volume is less that 50 cubic feet per 1000 BTU per hour 4 8m3 per kw of the aggregate input rating of all appliances installed in that space and an unconfined space as a space whose volume is not less that 50 cubic feet per 1000 BTU per hour 4 8m3 per kw of the aggregate input rating of all the appliances installed in that space Rooms communicating directly with the space in which the appliances are installed through openings not furnished with doors are considered a part of the unconfined space e WARNING if the area in which the heater may be operated is smaller than that defined as an unconfined Space provide adequate combustion and ventilation air by one of the methods described in the National Gas Fuel Code ANSI 2223 1 1992 section 5 3 e WARNING Do not allow fans to blow directly int
15. will go over grate bar Bottom front log is to be placed on front of grate and against front uprights as illustrated Front log should be centered Remaining logs are to be placed in numbered notches as illustrated WARNING Failure to position the parts in accordance with these diagrams or failure to use only parts specifically approved with this heater may result in property damage or per sonal injury NOTE Logs must be arranged so that the flames only touch bottom back log or front ember log Flames must not touch any other log in set NOTE Flames must not touch any part of firebox housing Damper handle firebox roof etc After positioning the logs on the burner grate pour the black lava rock in front of the ember log and around the sides to enhance the ap pearance Spread the allotted amount of ember material over the ember pipe positioned in the front ember log NOTE Do not exceed the allotted amount of embers provided with the set EMBER BURNER TUBE a vy aas Te GLOWING EMBER MATERIAL EMBER LOG miri Sint a PLACEMENT OF LOGS 24 amp 30 SETS Front ember log sits under front ember burner tube as shown Bottom back log is to be placed on back of grate and against burner support brackets as illustrated Notches in bottom log will go over grate bar Bottom front log is to be placed on front of grate and against front uprights as illustrated Front log should be cente
16. y hot when operating Keep children and adults away from hot surface Appliance will remain hot for some time after shutdown Allow surface to cool before touching e Do not use this appliance if any part has been submerged under water Immediately call a qualified technician to inspect the appliance and to replace any part of the control system and gas control which has been under water The installation must conform with local codes or in the absence of local codes with the National Gas Fuel Code ANSI 2223 1 e Never install the appliance in a bedroom bathroom mobile home or recreational vehicle where curtains furniture clothing or other flammable objects are less than 42 from the front of the appliance in high traffic areas in windy or drafty areas e Any outside air ducts and or ash dumps in the fireplace shall be permanently closed at time of appliance installation e Disconnect the gas appliance and its individual shut off valve from the gas supply piping system during any pressure testing of that system at test pressures in excess of 1 2 psig 3 5kPa e isolate the appliance from the gas supply piping system by closing its individual manual shut off valve during any pressure testing of the gas supply piping System at test pressure equal or less than 1 2 psig e Do not use any type of aftermarket blower that fits inside the fireplace Drafts created by these type of blowers may cause soo

Download Pdf Manuals

image

Related Search

Related Contents

Kurzanleitung Packard Bell dot s serie    Module 6 - Textura System::Login  Royal Sovereign ARP-7014  31 GTO de - Julien Mack  す て き - イヤホンガイドのレンタルなら、ケンネットまで  Documento na íntegra - Nescon - Universidade Federal de Minas    VRV-IIIC ColdRegion SiBE31-801C tcm135  Bedienungsanleitung Infrarot-Temperatursensor TW70xx  

Copyright © All rights reserved.