1. All Rights Reserved P MU DG600 Ver B Publish 2004 08 27 Page 5 6 G EM GIANNI INDUSTRIES INC m Alarm Function Enter the Programming Mode Press 2 A Alarm Setup Input time 01 99 05 represents 50 seconds B To turn off alarm function Input 00 Example 1 Door Held Open Alarm If the relocking timer is set for 5 seconds and the Alarm Setup is set for 10 seconds the following will happen If the door has been opened via a valid card or PIN codes but has remained open for more than 15 seconds then an audible alarm will sound and the RED LED will flash and remain until the door has been closed correctly This activation is controlled using contacts E and V Example 2 Door Forced Alarm same example If the door is opened without the use of a valid card or PIN codes the audible alarm will sound and the RED LED will flash and remain until the door has been closed correctly This activation is controlled using contacts E and V Example 3 Panel Tamper Alarm The main panel has a anti tamper micro switch installed if the main panel is opened the audible alarm will sound and the RED LED will flash and remain until the panel has been closed correctly m Changing the Master codes An audible beep enrolled completed Enter to exit from the programming mode or program other operating m Reset Function A To Reset the master code only Return to default setting 12345 Insert the j
2. St2 connect to 2 3 Fail Safe Lock St2connectto 1 2 gt Contact door switch or the Push Button ZS Powersupply TA 10 15Vdc J Se art Linear supply recommended Jf ae cfeceeeheeseeceeceecetecencetced the warning system Auxiliary Reader Wiegand Format Insert 2 3 position to reset eee tee eee eee eee ee tee ee terete tree ee tee eee teeter tees Connectto 1 2 C and D contactis N C Connect to 2 3 for N O Connectto 1 2 C andA contactis N C Connect to 2 3 for N O Note 1 DG 600 auxiliary reader must not be further than 20 meters from the host Also this reader should be nearer than 30 centimeters to avoid disturbance The suggested wire gauge is 22 26 AWG 2 DG 600E important instructions At the back of the main PC board JP1 see wiring diagram The system storage card form is Wiegand 44 bits When you have Wiegand 26 bits auxiliary reader please do use the solder to short JP1 to turn to Wiegand 26 bits HEX form the auxiliary reader stores different card this produce invalid card readings 3 DG 600H the card storage form is Wiegand If short circuits JP1 turns Wiegand 26 bits form can only read Wiegand 26 bits to the system 4 DG 600E DG 600H when JP1 has the change there s a possibility the card stored would be invalid Reset to input the card 5 The varistor or diode must be connected across the lock
3. awaiting input of PIN oes Flashing _ codes ignas Green LED Slot Position ready to store card Red LED Memory slot already has a card registered User Signals 1 Beep ea presented Any key pressed 4 Beeps Invalid card gt Data computing error Sound Bea The input data is correct Enters or Exit signal Programming p Programming mode Signals Input mistake or other operation mistakes A BERE duplicate card Default Settings Access Mode Format Read Card only 00 All bits 44 bit or 26 37 bit Card register None Master Codes 12345 5 digits All Alarm function Defeat able 00 Relocking timer 5 seconds Pressed key delay time Time Out 5 seconds Waiting input PIN codes time 5 seconds Setting mode delay time 25 seconds Terminal connections CN1 Contacts on block for the system CN2 Contacts on block for auxiliary reader 12 8 5 16 Vdc 12 8 5 16 Vdc V GND gt Power ground V GND gt Power ground D Electrified lock pa PAAT Sgan Dalal c Electrified lock Alarm Common DO DATAO Wiegand Data 0 COM A Alarm Common LED LED contact E Door reed switch BEEP Beeper contact B Request to exit Copyright Gianni Industries Inc All Rights Reserved P MU DG600 Ver B Publish 2004 08 27 Page 3 6 G EM GIANNI INDUSTRIES INC IV Wiring diagram electric lock signal output Fail S ecure Lock
4. deleting cards Enter the Programming Mode Press the card storage slot code 000 599 A Green light comes on This slot code may register the card l Show card to reader gt Yellow light blinks gt input 5 digits PIN codes gt Green light off gt enrolled completed gt repeat Il Show card to reader gt 4 audible beep another card has already been input duplicate card B Red light comes on This slot already has a code registered l Press x gt deletion gt Green light comes on gt Show card to reader gt same as step A 1 Il Enter another slot card position Note 1 Regardless of system setting access mode select you must enter a 5 digit PIN codes after showing the card to complete the register program otherwise the card input will not be successful Note 2 The master code are not be used for PIN code Relocking timer setting Enter the Programming Mode Press x1 A Pulse mode 01 99 seconds 05 represents 5 seconds gt An audible beep indicates setting successfully to exit from the programming mode or program other operating B Latching mode 00 gt An audible beep indicates setting successfully to exit from the programming mode or program other operating Note Enter 00 Sets the relay to latching mode Correct code or card entered opens the relay and the relay stays open until the correct code or card is entered again Copyright Gianni Industries Inc
5. terminal electromagnet operated by the device The vartistor controls the overload produced by the strike coil EMP 6 Egresses switch is in N O Condition 7 Alarm system use C A contact start with external relay 8 Using a Linear supply power recommended to prevent power reduction at the card reader Copyright Gianni Industries Inc All Rights Reserved P MU DG600 Ver B Publish 2004 08 27 Page 4 6 G EM GIANNI INDUSTRIES INC V Operation Instruction WARNING Please read all of operation instruction before proceeding m Enter Program Mode Enter twice the master code Default setting is 12345 Yellow LED will light up you are now in the Programming Mode m Exiting from the Program Mode Press to exit from the programming mode or if no activation has happened for 25 seconds the system will return to the user mode m System Setting Access Mode Enter the Programming Mode Press 0 A Proximity Only For Using Card Tag Only 00 setting complete B Proximity or PIN Code to open the door 01 setting complete C Proximity PIN to open the door Card followed by PIN code to enter 02 the setting is complete Note 1 After using the proximity card the yellow LED blinks and input the PIN codes If wrong PIN code is input it will automatically return to the User Mode Note 2 5 continuous wrong pin codes will automatically deletes the card m Adding and
6. G EM GIANNI INDUSTRIES INC DG 600 Standalone Proximity Reader Operation User s Manual Product Characteristic DG 600 has a 600 cards and PIN codes capacity and a reading time of 0 5 second max Transmitted to the host with extended Wiegand format auxiliary reader The Unit will operate with card only PIN or card PIN card The logical memory does not allow duplicate cards to be programmed The host unit will lockout for 60 seconds if 5 incorrect password attempts are entered Beeper sound gives positive signal of all keypad activations Build in tamper switch that turns on alarm relay to ensure vandal proof operation Non volatile memory stores all programmed information for at least 10 years even in the event of total power failure Removable memory chip in the main control module allows on site replacement in the event of break down Fully Programmable via keypad and master code Copyright Gianni Industries Inc All Rights Reserved P MU DG600 Ver B Publish 2004 08 27 Page 1 6 G EM GIANNI INDUSTRIES INC Il Specifications Operating Voltage Current Draw DC 8 5V to 16V Average 50mA Peak 100mA 12Vdc Transmitting Frequency 125 KHz Memory Volume 600 Proximity cards tokens and PIN codes Read Range Up to 10 cm Depending on local installation conditions Keyboard 12 digits keypad 0 9 Input Request to exit door reed switch auxiliary reader Relay Electr
7. ic Current 2A MAX 30Vdc 0 4A 120Vac Invalid PIN Lock out The system will shut down for 60 seconds while 5 times of incorrectly Master Codes enrolled or PIN codes attempted None beeper signal of keypad activations Dye Strike Time 1 99 seconds adjustable Relocking timer Strike mode Access Timer or Latch Door Held Open Alarm 10 990 Alarm Function Door Forced Alarm Panel Temper Alarm Format DG 600E Wiegand 44 or 26 bit only format adjustable hexadecimal Em 64 bit standard R O or compatible DG 600H Wiegand 26 37 or 26 bit only format adjustable hexadecimal 125KHz 26 37 bit R O or compatible Case Material Color ABS UL94V0 Dark gray Beige White Operating Temperature 20 70 C Ambient Humidity 5 95 relative humidity non condensing Visual Signals 3 LED display with audible indication Red Yellow Green EMC Meet CE requirement Copyright Gianni Industries Inc All Rights Reserved P MU DG600 Ver B Publish 2004 08 27 Page 2 6 G EM GIANNI INDUSTRIES INC III The indicator signal chart Sound and LED indicator Mode Signal Condition Yellow CER Power on Stand by User Signals Flashing slowly Green LED Valid entry lock relay active Red LED Warning Invalid Card or code Tamper LED Yellow LED Programming mode entered signal Yellow LED Card has been read
8. umper 2 3 position Green LED will flash An audible beep completed gt Return Insert the jumper ST 1 to 1 2 position Note Remove jumper after Yellow LED has been flashing for 5 Seconds If the jumper is NOT removed then the system will TOTALLY reset and remove all stored information B Totally reset remove all stored information Insert the jumper ST1 2 3 position Green LED will flash An audible beep Red LED will flash An audible beep all parameters reset Return Insert the jumper ST1 to 1 2 position Copyright Gianni Industries Inc All Rights Reserved P MU DG600 Ver B Publish 2004 08 27 Page 6 6

Download Pdf Manuals

image

Related Search

Related Contents

Dell D2215H Monitor Outline Dimensions  User Manual - Videoswitch    USR-C322 - Low Power Minisize WiFi Module User Manual V1.3  Manual Di600 SP Rev0613.1.0  Simpson Strong-Tie CC44HDG Installation Guide  Installation  Moog Videolarm PRM50G  取扱説明書 Windows NT4.0編  NOTICE URGENTE RELATIVE À LA SÉCURITÉ D`UTILISATION  