Home

GE W4L Installation Guide

image

Contents

1. GE Lighting Solutions READ THOROUGHLY BEFORE INSTALLING INSTALLATION Read these instructions carefully before proceeding with installation of this product Failure to follow instructions may result in improper operation or voiding of warranty A WARNING Risk of electric shock e Turn power off before servicing see instructions A WARNING Risk of fire e Use supply wire specified on nameplate MOST DWELLINGS BUILT BEFORE 1985 HAVE SUPPLY WIRE RATED 60C CONSULT A QUALIFIED ELECTRICIAN BEFORE INSTALLING GENERAL Upon receipt of fixture thoroughly inspect for any freight damage which should be brought to the attention of the delivering carrier Compare the catalog description listed on the packing slip with the fixture label on the package to assure you have received the correct merchandise Door Screw Reflector Door Screw Reflector Barrier Reflector Barrier Screw Screw Figure A Open View GEH 5825 INSTRUCTIONS Wallmount 400 Luminaire MOUNTING A CAUTION Unit will fall if not installed properly e Follow installation instructions 1 Loosen screws securing lens door Open lens door wide enough to lift from hinges and remove See Figure A 2 Remove lamp reflector and fiber ballast barrier See Figure A 3 This unit is designed for attachment to 1 2 ridged conduit at the sides top and back See 1 s Figure B It may be necessary to drill out mounting bos
2. Lighting Solutions The GE brand and logo are trademarks of the General Electric Company 2011 GE Lighting Solutions Information provided is subject to change without notice All values are design or typical values when measured under laboratory conditions 35 201578 8H 12 00
3. en particulier pour le type de ballast la position d utilisation etc Serrage de lampe culot goliath La lampe doit tre ins r e de fa on s re avec un couple de serrage NEMA EEI sp cifi 4 4 mkg 35 livre pouce ce qui est le mieux r alis en serrant fortement la main pour mettre un couple suffisant Le serrage doit compl tement appuyer et charger le contact central de la douille avec le culot de la lampe ENTRETIEN Cet appareil Wallmount 400 est con u pour des ann es de fonctionnement sans probl mes Pour une perfor mance optimale nettoyez p riodiquement le r flecteur et le r fracteur avec un nettoyant non abrasif D PANNAGE Dans l ventualit o votre appareil cesserait de fonctionner correctement v rifiez en premier que Une lampe du bon mod le est install e correctement Cette lampe n est pas grill e Le tension d alimentation arrivant sur l appareil est correcte L appareil est cabl de fa on appropri e L appareil est bien reli la terre Or OT ECS ea La cellule photo lectrique optionnelle install e est de la bonne tension et de la bonne puissance 7 I n y a pas de lumi re r fl chie revenant dans la cellule photo lectrique qui entrainerait l extinction du luminaire GE Lighting Solutions e 1 888 MY GE LED e www gelightingsolutions com 1 888 69 43 533 GE Lighting Solutions is a subsidiary of the General Electric Company Evolve and other trademarks belong to GE
4. ever voir sch ma A 2 Enlevez la lampe le r flecteur et la barri re de ballast en fibre voir sch ma A 3 Ce mod le est con u pour une fixation sur une conduite cannel e de 1 2 pouce par les c t s le dessus le dessous et l arri re voir les 1 sur le sch ma B Il pourra tre n cessaire de percer des bossages de fixation pour la visserie de montage voir les emplacements 2 sur le sch ma B 4 Dans toutes les configurations de montage tanch ifiez correctement les trous de montage pour emp cher que de l eau n entre dans le luminaire par l arri re Il faut utiliser un calfateur de bonne qualit comme du RTV 108 ou un quivalent 5 Fixez convenablement l appareil sur la surface de montage avec la visserie ad quate et reliez la conduite comme indiqu pr c demment NOTE L appareil doit se monter en conformit avec l tiquette de positionnement qui se trouve dans le compartiment de la lampe 6 R alisez le c blage en suivant les instructions plus loin 7 Remettez en place la barri re de ballast en fibre le r flecteur la lampe et la porte de lentille Sch ma B Vue arri re du luminaire Ces instructions n ont pas pour destination de couvrir tous les d tails ou variantes de l quipement ni de r pondre toutes les ventualit s que vous pourriez rencontrer pendant l installation le fonctionnement ou l entretien Si vous souhaitez des info
5. ixture is supplied with a multitap ballast it is set to 277 volts If 120 208 or 240 volts is desired Cap 277 volt lead and strip appropriate voltage lead Connect to incoming hot lead using proper wire connectors LAMP INSTALLATION CAUTION Risk of burn e Allow lamp fixture to cool before handling WARNING Risk of burn e Do not touch operating luminaire Use only lamps specified on nameplate Observe lamp manufacturer s recommendations and restrictions on lamp operation particularly ballast type burning position etc Lamp Tightness Mogul Base Lamp The lamp should be securely inserted to the NEMA EEI specified torque of 35 inch pounds which is best achieved by very firmly tightening to insure application of sufficient torque Tightening must be sufficient to fully depress and load the center contact of the socket MAINTENANCE This Wallmount 400 fixture is designed for years of trouble free operation For optimum performance periodically clean the reflector and refractor with a non abrasive cleaner TROUBLE SHOOTING In the event your fixture fails to operate properly first check that The correct lamp is properly installed The lamp is not faulty The line voltage at the fixture is correct The fixture is wired properly The fixture is grounded properly The optional photocell is of proper voltage and wattage There is no reflected light back into the photocell causing the fi
6. rmations compl mentaires ou si vous rencontrez un probl me particulier qui ne soit pas adress de votre point de vue d acheteur le sujet doit tre remont jusqu la soci t GE Lighting Solutions CABLAGE Effectuez tous les raccordements en conformit avec les normes nationales et les ventuels r glements locaux applicables V rifiez que la tension secteur disponible est la bonne en comparant avec l indication de tension sur la plaque d identification N enlevez pas les connecteurs isol s des fils non concern s par le raccordement de la tension Quand le mod le est livr avec une liaison en mono tension v rifiez bien que la tension secteur disponible correspond bien celle pr conis e sur l appareil Quand l appareil est livr avec un ballast multi prises il est en sortie d usine configur pour du 277 volts Si c est une alimentation en 120 208 ou 240 volts qui est d sir e Isolez le fil correspondant aux 277 volts d nudez l extr mit du fil de la tension voulue Connectez le au fil de phase d arriv e en utilisant une cosse isolante ad quate INSTALLATION DE LAMPE A ATTENTION Risque de br lure e Laissez le bloc d ampoule refroidir avant d y toucher DANGER e Risque de br lure e Ne touchez pas le luminaire allum N utilisez que le type de lampe sp cifi sur la plaque d identification Observez les recommandations et restric tions du fabricant sur le fonctionnement de la lampe
7. ses for attachment hardware See 2 s Figure B 4 In any mounting configuration properly caulk mount ing holes to prevent water from entering fixture from behind A high grade caulk such as RTV 108 or equiva lent should be used 5 Properly secure fixture to mounting surface with appro priate hardware and connect conduit as indicated above NOTE Fixture to be mounted according to position label inside lamp compartment 6 Attach wiring according to instructions below 7 Re install fiber ballast barrier reflector lamp and lens door Ballast Barrier Figure B Back View These instructions do not purport to cover all details or variations in equipment nor to provide for every possible contingency to be met in connection with installation operation or maintenance Should further information be desired or should particular problems arise which are not covered sufficiently for the purchaser s purposes the matter should be referred to GE Lighting Solutions WIRING Make all electrical connections in accordance with the National Electrical Code and any applicable local code requirements Verify that supply voltage is correct by comparing it to nameplate Do not remove insulated connectors from wires not needed for required voltage connection When this fixture is supplied with single voltage lead please make sure the voltage furnished to the fixture is the same as specified on the unit When f
8. xture to turn off SNS OO FWD e VIS DE PORTE GE Lighting Solutions A LIRE AVEC SOIN AVANT D INSTALLER INSTALLATION Lisez soigneusement ces instructions avant de commencer l installation de ce luminaire Leur non respect peut entra ner un mauvais fonctionnement ou annuler la garantie Risque d electrocution e Mettre hors tension avant d intervenir Suivez les instructions A4 DANGER Risque d inflammation e Utilisez les fils d alimentation sp cifi s sur la plaque d identification AUX USA LA PLUPART DES HABITATIONS BATIES AVANT 1985 ONT UN CABLAGE SECTEUR DE TYPE 60C CONSULTEZ UN ELECTRICIEN PROFESSIONNEL AVANT L INSTALLATION G N RALIT S la r ception de l appareil cherchez d ventuels dommages d s au transport qui doivent tre signal s au transporteur Comparez la description port e sur le bon de livraison avec l tiquette de l appareil sur son emballage pour vous assurer que vous avez bien re u la marchandise attendue VIS DE PORTE LAMPE R FLECTEUR CHARNI RE BALLAST VIS DE REFLECTEUR REFLECTEUR BARRIERE BARRIERE Sch ma A Vue luminaire ouvert BARRI RE DE GEH 5825 INSTRUCTIONS Luminaire Wallmount 400 MONTAGE A ATTENTION Risque de chute en cas de mauvais montage Suivez les instructions Re Desserrez les vis retenant la porte de lentille Ouvrez la assez pour la d boiter de ses charni res et l enl

Download Pdf Manuals

image

Related Search

Related Contents

Bedienungsanleitung AG-Waagen  Danby dac10507ee User's Manual  Fujitsu C150-E049-02EN Photo Scanner User Manual  8367N ゲニュ ディレクサ ステーブル 取扱説明書  

Copyright © All rights reserved.
Failed to retrieve file