Home

GE P16M Installation Guide

image

Contents

1. GE Lighting Solutions GEH 3912C INSTRUCTIONS PM 17 amp PM 16 READ THOROUGHLY BEFORE INSTALLING A WARNING Risk of electric shock Turn power off before servicing seeinstructions GENERAL This luminaire is designed for outdoor lighting applications and should not be used in areas of limited ventilation or in high ambient temperature enclosures Best results will be obtained if the luminaire is installed and maintained according to the following recommendations UNPACKING This luminaire has been properly packed to protect it during transit Unpack inspect and notify the distributor or shipping agent of any damage found MOUNTING A CAUTION Unit will fall if not installed properly e Follow installation instructions This luminaire is provided with means for mounting on 2 in 2 375 O D to 3 in 3 500 O D pole tops INSTALLATION Refer to figure A Make all electrical connections in accordance with the National Electrical Code and any applicable local code requirements TERMINAL BOARD START AID HPS ONLY FUSES OPTIONAL Figure A START AID Figure B 1 Certain models have a shield to protect the user from exposure to electrical components while relamping This shield must be removed to install power supply leads to the terminal board This shield MUST be replaced after maki
2. ent solutions and rinse with cool water NOTE The refractor is keyed to the collar with the street side opposite the hinge These should be aligned at re assembly Light output is dependent on the age of the lamp In applications where light level is critical it may be desir able to replace lamps before their end of life The lamp manufacturer can provide data showing how the lamp light output decreases with use GE Lighting Solutions e 1 888 MY GE LED e www gelightingsolutions com 1 888 69 43 533 GE Lighting Solutions is a subsidiary of the General Electric Company Evolve and other trademarks belong to GE Lighting Solutions The GE brand and logo are trademarks of the General Electric Company 2011 GE Lighting Solutions Information provided is subject to change without notice All values are design or typical values when measured under laboratory conditions 35 201578 F4 9 06
3. ng the supply connections See Figure B 2 Feed the power supply leads through the slip fitter wire access hole as the fixture is installed on the pole Level and secure the fixture to the pole by tightening the three set screws in the slipfitter 3 Connect power supply leads to the terminal board making sure that the ground lead is mated with the terminal receiving the green grounding wire These instructions do not purport to cover all details or variations in equipment nor to provide for every possible contingency to be met in connection with installation operation or maintenance Should further information be desired or should particular problems arise which are not covered sufficiently for the purchaser s purposes the matter should be referred to GE Lighting Solutions Verify that supply voltage is correct by comparing it to nameplate IF SINGLE VOLTAGE All single voltage ballasts are pre wired such that user need only connect the supply conductors IF MULTIVOLT 120 208 240 277 volts Connect the ballast lead with the insulated terminal to the desired voltage terminal as indicated on the ballast terminal nameplate IF MULTIWATT Multiwatt ballasts are available in various combinations of wattage See wiring instructions on wiring tag inside the luminaire 4 Re install shield noted above if removed and install lamp 5 Install the canopy The hinges can only be as sembled when the canopy is tilted up about 40 deg
4. rees It will rest in the fully open position but should be braced while working with the fixture to prevent injury Reassemble the PE receptacle connectors if provided close and latch canopy LAMPS CAUTION Risk of burn Allow lamp fixture to cool before handling Use only lamps specified on nameplate Observe lamp manufacturer s recommendations and restrictions on lamp operation particularly ballast type burning position etc LAMP TIGHTNESS The lamp should be securely inserted to NEMA EEI specified torque of 35 inch pounds which is best achieved by very firmly tighten ing to insure application of sufficient torque Tightening must be sufficient to fully depress and load center contact of socket INSTALLATION OF SCROLLS FOR PM 16 LUMINAIRE Three 3 scrolls amp three 3 thread forming screws are packed unassembled in the shipping carton To install each of the scrolls on the luminaire hook it s tab into one of the three 3 sockets on the under side of the rim that is below the refractor See Figure C Secure the scroll at the bottom of the fixture with one of the three screws provided SCROLL SOCKET 3 PLACES Figure C MAINTENANCE AND CLEANING Periodic cleaning of the refractor will ensure operation at maximum optical efficiency The refractor may be removed by loosening three tie bolts and rotating the securing collar Wash with non abrasive soap cleaner or deterg

Download Pdf Manuals

image

Related Search

Related Contents

Caja externa USB 3.0 para HDD de 3.5" (8,89cm) Manual del usuario  Acer TM7300 User's Manual  Vertex Standard TRANSCEIVER VX-1700 User's Manual  クイックヒッチ仕様  1 - Olivier Houdé  1 2 取扱説明書  TEFAL DDJ20641 Instruction Manual  MPU Series B Winscreen User Manual Procedure Manual  Tristar 6 in 1 Grooming kit  Manual del Propietario  

Copyright © All rights reserved.
Failed to retrieve file