Home

GE DI Series Round Wall Wash Installation Guide

image

Contents

1. in accordance with National Electric Code NEC Article 600 and local codes imagination at work Unit Installation Fixture Hole Size 4 in round fixture 5 in 126mm diameter hole ZA 6 in round fixture 6 in 165mm diameter hole R LALA lt 4 in square fixture 5 in x 51 2 in 140mm x 140mm RA 6 in square fixture 7 in x 7 in 178mm x 178mm 1 Cut the appropriate size hole into ceiling tile see table at right 2 Slide hanger bars through 3 Option A Mount fixture by 3 Option B Mount fixture with 1 2 adjustable mounting brackets attaching hanger bars to EMT conduit T Grid ceiling BH3 SKU 94890 Note Supplied by 3rd party A fs O Adjust fixture height to be Dust off any particles that may O Slide reflector into the fixture flush with ceiling and secure have adhered to connection Verify reflector trim is flush with by tightening both adjustable points and heat sink during ceiling Repeat Step 4 if trim is mounting bracket wingnuts installation process with a dry not flush cloth or compressed air Twist Infusion downlight module into holder For wall wash reflectors position reflector so that light is directed towards wall UOTE Electrical Connections 0 10V dimming controller optional Connect the black line of the AC line to the black 120V 277V ae or 347V wire Connect the white neutral wires of the AC line odie to the white wires using the provided 18 12 A
2. GE Installation Guide Lighting Lumination LED Luminaire DI Series BEFORE YOU BEGIN Read these instructions completely and carefully AX WARNING AVERTISSEMENT RISK OF ELECTRIC SHOCK RISQUES DE DECHARGES ELECTRIQUES e Turn power off before inspection installation or removal e Coupez l alimentation avant d inspecter installer ou d placer le luminaire e Properly ground electrical enclosure e Assurez vous de correctement mettre la terre le bo tier d alimentation lectrique RISK OF ELECTRIC SHOCK RISQUES D INCENDIE e Follow all NEC and local codes e Respectez tous les codes NEC et codes locaux e Use only UL approved wire for input output connections e N utilisez que des fils approuv s par UL pour les entr es sorties de Minimum size 18 AWG or 14 AWG for continuous runs connexion Taille minimum 18 AWG ou 14 AWG pour les rang es continues Save These Instructions Use only in the manner intended by the manufacturer If you have any questions contact the manufacturer Prepare Electrical Wiring Electrical Requirements Ra e The LED driver must be supplied with 120V for DIXXXXXXX1VXX fixtures 277V for DIXXXXXXX2VXX fixtures and 347V for DIXXXXXXX3VXX fixtures 50 60 Hz and connected to an individual properly grounded branch circuit protected by a 20 ampere circuit breaker Use min 75 C supply conductor Grounding Instructions e The grounding and bonding of the overall system shall be done
3. WG push in holder connectors Connect the green wire to the ground screw Optional If using a 0 10V dimming controller connect matching colored wires together Risk of damage Make sure that supply connection light fixture wiring and dimming cables are connected to proper driver inputs Wrong connection may cause damage to the product Must use UL approved conduit fittings for all enclosure box connections to prevent wire cuts by sharp edges and excessive strain on wiring Wiring the Thermal Protector 0 10V Dimming Lighting Controller optional 0 10V wiring diagram Line black ie Neutral white Neutral DRIVER Ground green 1 10 violet 1 10 gray 0 10V THERMAL PROTECTOR Ground 0 10v Common Make appropriate connections to the output wires of the LED driver using twist on wire connectors Follow lighting controller installation instructions NOTE For 0 10V dimming SKUs THERMAL PROTECTOR Lutron Ecosystem Lighting Controller optional Ecosystem Wiring Diagram EcoSystem purple Common EcoSystem purple Line black DRIVER See Note Neutral white Ground green THERMAL PROTECTOR Note DL for use with 3 wire fluorescent control Lutron System Neutral Common 347V TRANSFORMER Black 347V Input Troubleshooting Symptom Solution Luminaire does not light e Check input voltage and check power supply input output connections e Check circuit brea
4. art 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense Fixture intended for commercial use only Use only in non insulated applications GE Lighting 1 888 MY GE LED 1 888 69 43 533 www gelighting com GE Lighting Solutions LLC is a subsidiary of the General Electric Company The GE brand logo Lumination are trademarks of the General Electric Company 2015 GE Lighting Solutions LLC Information provided is subject to change without notice All values are design or typical values when measured under laboratory conditions IND077 022315
5. ker e Check that the color of the supply side wires match the color of the wires they are connected to e Check that the LED driver connector is fully engaged to the LED light engine connector e Check that the LED light engines are connected at the junction between the two luminaires Luminaire is dim e Dimming wire connection shall be checked and if connection is not proper reconnect it If wire is harmed replace it with an intact one Also check that dimming wires are not in short circuit e Check that LED module is firmly seated in module holder and twisted in tightly Luminaire does not dim e Check dimming wire connection Through Wiring Lumen Level Maximum number of fixtures 1000 1500 2000 lumen 30 3000 4000 lumen 20 15A Circuit Minimum Spacing Requirements a Center to center of adjacent luminaries 24 b Top of luminaire to overhead building member 2 5 c Luminaire center to side of building member I2 This device complies with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation This Class A RFLD complies with the Canadian standard ICES 003 Ce DEFR de la classe A est conforme la NMB 003 du Canada Note This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to p