Home
GE DCVH680EJBB User's Manual
Contents
1. 12 Loosely fasten the hinge assembly to the edge using 2 machine screws 8 9 Remove the 2 nuts washers and the 2 machine screws 8 13 Hold the door on its side with one hand and fasten the remaining 2 screws as shown Then tighten the 2 screws 8 holding the hinge assembly 10 Remove the hinge assembly by removing the 2 machine screws 8 that fasten it to the frame Pull the hinge assembly out and set it aside Installation Instructions REINSTALL NUTS AND HINGE COVER 14 Place the door on its edge Assemble the 2 machine screws 8 washers and nuts Tighten using a wrench and screwdriver So 2 ak oN y Sy Q 15 Place the hinge cover in position Align the hinge cover holes with the holes in the door REASSEMBLE DOOR ASSEMBLY IMPORTANT Make sure there is no dirt or any other foreign material in between the window panes 17 Place the plastic cover onto the inner door and lock in place with the 4 tabs Top of Door 19 After reversing door there will be a mismatch between the outer door and the inner door Make sure that the handle part of the outer door is opposite the hinge as shown Installation Instructions 20 Turn the door over and fasten the outer door to the inner REINSTALL DOOR ASSEMBLY door using the 6 large tapping screws 10 23 The door is now ready to be installed on the dryer To ease this step the hinge has keyholes that allow a p
2. lo ALCOVE OR CLOSET INSTALLATION If your dryer is approved for installation in an alcove or closet it will be stated on a label on the dryer back The dryer MUST be vented to the outdoors See the EXHAUST INFORMATION sections 3 amp 4 Minimum clearance between dryer cabinet and adjacent walls or other surfaces is O in either side 3 in front and rear Minimum vertical space from floor to overhead cabinets ceiling etc is 43 in without pedestal 55 in with pedestal Closet doors must be louvered or otherwise ventilated and must contain a minimum of 60 sq in of open area equally distributed If the closet contains both a washer and a dryer doors must contain a minimum of 120 sq in of open area equally distributed NOTE WHEN THE EXHAUST DUCT IS LOCATED AT THE REAR OF THE DRYER MINIMUM CLEARANCE FROM THE WALL IS 5 5 IN BATHROOM OR BEDROOM INSTALLATION e The dryer MUST be vented to the outdoors See EXHAUST INFORMATION section 3 amp 4 e The installation must conform with local codes or in the absence of local codes with the NATIONAL ELECTRICAL CODE ANSI NFPA NO 70 MOBILE OR MANUFACTURED HOME INSTALLATION Installation must conform to the MANUFACTURED HOME CONSTRUCTION amp SAFETY STANDARD TITLE 24 PART 32 80 or when such standard is not applicable with AMERICAN NATIONAL STANDARD FOR MOBILE HOME ANSI NFPA NO 501B The dryer MUST be vented to the outdoors with the termina tion securely fastened
3. CONDUCTORS OR 120 240V 30A POWER SUPPLY CORD KIT MARKED FOR USE WITH DRYERS amp PROVIDED WITH CLOSED LOOP OR SPADE TERMINALS WITH UPTURNED ENDS NOT SUPPLIED Installation Instructions 1 Turn off the circuit breaker s 30 amp or remove the dryer s circuit fuse at the electrical box 2 Be sure the dryer cord is unplugged from the wall receptacle 3 Remove the power cord cover located at the lower back 4 Remove and discard ground strap Keep the green ground screw for step 7 5 Install 3 4 in UL recognized strain relief to power cord entry hole Bring power cord through strain relief 6 Connect power cord as follows A Connect the 2 hot lines to the outer screws of the terminal block marked L1 and L2 B Connect the neutral white line to the center of the terminal block marked N 7 Attach ground wire of power cord with the green ground screw hole above strain relief bracket Tighten all terminal block screws 3 completely 8 Properly secure power cord to strain relief 9 Reinstall the cover AX WARNING NEVER LEAVE THE COVER OFF OF THE TERMINAL BLOCK CONNECTING DRYER USING 3 WIRE CONNECTION If required by local code install external ground not provided to grounded metal cold water pipe or other established ground determined by a qualified GREEN GROUND GROUND STRAP SCREW HOT WIRE Q STRAIN RELIEF electrician BRACKET U Sa 3 4 UL y UR yp 7 7
4. X So CH fod GAN A Mi RECOGNIZED SIN STRAIN RELIEF NEUTRAL HOT 3 10 AWG MINIMUM COPPER CONDUCTORS OR 120 240V 30A POWER NSS SUPPLY CORD KIT MARKED FOR USE WITH DRYERS amp PROVIDED WITH CLOSED LOOP OR SPADE TERMINALS WITH UPTURNED ENDS NOT SUPPLIED 1 Turn off the circuit breaker s 30 amp or remove the dryer s circuit fuse at the electrical box 2 Be sure the dryer cord is unplugged from the wall 3 Remove the power cord cover located at the lower back 4 Install 3 4 in UL recognized strain relief to power cord entry hole Bring power cord through strain relief 5 Connect power cord as follows A Connect the 2 hot lines to the outer screws of the terminal block marked L1 and L2 B Connect the neutral white line to the center of the terminal block marked N 6 Be sure ground strap is connected to neutral center terminal of block and to green ground screw on cabinet rear Tighten all terminal block screws 3 completely 7 Properly secure power cord to strain relief 8 Reinstall the cover WARNING NEVER LEAVE THE COVER OFF OF THE TERMINAL BLOCK EXHAUST INFORMATION A WARNING IN CANADA AND IN THE UNITED STATES THE REQUIRED EXHAUST DUCT DIAMETER IS 4 IN 102mm DO NOT USE DUCT LONGER THAN SPECIFIED IN THE EXHAUST LENGTH TABLE Using exhaust longer than specified length will e Increase the drying times and the energy cost e Reduce the dryer life e Accumulat
5. e Avoid resting the duct on sharp objects UL LISTED FLEXIBLE METAL FOIL TYPE TRANSITION DUCT e In special installations it may be necessary to connect the dryer to the house vent using a flexible metal foil type duct A UL listed flexible metal foil type duct may be used ONLY in installations where rigid metal or flexible metal semi rigid ducting cannot be used AND where a 4 diameter can be maintained throughout the entire length of the transition duct In Canada and the United States only the flexible metal foil type ducts that comply with the Outline for Clothes Dryer Transition Duct Subject 2158A shall be used Never install flexible metal duct in walls ceilings floors or other enclosed spaces Total length of flexible metal duct should not exceed 8 feet 2 4m Avoid resting the duct on sharp objects e For best drying performance 1 Slide one end of the duct over the clothes dryer outlet pipe 2 Secure the duct with a clamp 3 With the dryer in its permanent position extend the duct to its full length Allow 2 of duct to overlap the exhaust pipe Cut off and remove excess duct Keep the duct as straight as possible for maximum airflow 4 Secure the duct to the exhaust pipe with the other ELBOW HIGHL RECOMMENDED DO NOT SIT DRYER ON FLEXIBLE EXHAUST DO NOT USE EXCESSIVE EXHAUST LENGTH FLEXIBLE EXHAUST 3 AGAINST JS wa
6. located around the perimeter of the door outlining the gasket and the 2 machine See screws 8 on the hinge side 2 8 Machine Cos Screws AN 6 10 Large 5 Screws REMOVE DOOR ASSEMBLY 2 Open the door to approximately 90 degrees Remove the 4 screws starting from the bottom to the top Make sure the door is supported while removing the screws 2 8 Machine Screws 6 With the screws removed turn the door over and separate A the silver cover part of the door from the door frame and set A aside k l NOD A IJ RX Remove the ja Mi four screws 4 D j S i G 2 a gt S 7 VG AR tja In 3 Loosen the top screw as shown Unhook the door by lifting and pulling as shown by the arrows 7 Unlock the 4 tabs on the plastic cover and separate the plastic cover from the frame NOTE Disregard the DO NOT REMOVE label on the plastic cover Installation Instructions REMOVE HINGE REINSTALL HINGE ASSEMBLY IMPORTANT Note the location of the hinge left or right before 11 Place the hinge assembly in the opposite side of the door removing Align the hinge holes with the door holes 8 With the door frame part of the door laid down on a protected soft surface remove the hinge cover by removing the 2 tapping screws 8 that fasten it to the frame The hinge cover is located at the opposite side of the hinge assembly
7. 90 e One turn of 45 or less may be ignored e Two 45 turns should be treated as one 90 turn e Each turn over 45 should be treated as one 90 turn SEALING OF JOINTS e All joints should be tight to avoid leaks The male end of each section of duct must point away from the dryer e The duct shall not be assembled with screws or other fastening means that extend into the duct and catch lint e Duct joints can be made air and moisture tight by wrapping the overlapped joints with duct tape e Horizontal runs should slope down toward the outdoors 1 2 inch per foot INSULATION Duct work that runs through an unheated area or is near air conditioning should be insulated to reduce condensation and lint build up Installation Instructions EXHAUST CONNECTION A WARNING TO REDUCE THE RISK OF FIRE OR PERSONAL INJURY This clothes dryer must be exhausted to the outdoors Use only 4 rigid metal ducting for the home exhaust duct Use only 4 rigid metal or UL listed flexible metal semi rigid or foil type duct to connect the dryer to the home exhaust duct It must be installed in accordance with the instructions found in Connecting The Dryer To House Vent on page 5 of this manual Do not terminate exhaust in a chimney a wall a ceiling gas vent crawl space attic under an enclosed floor or in any other concealed space of a building The accumulated lint could create a fire hazard Never terminate the exhaust into
8. Supply and Dryer see section 1 Venting Check and Ensure the Existing External Exhaust is Step 9 Place the Owners Manual and the Installation Clean see section 1 and Meets Attached Installation Instructions in a Location Where They Will Be Specifications see section 3 Noticed By the Owner Remove the Foam Shipping Pads see section 1 Move the Dryer to the Desired Location For Alcove or Closet Installation see section 6 Connect the Power Supply see section 2 For Bathroom or Bedroom Installation see section 7 Connect the External Exhaust see section 4 For Mobile or Manufactured Home see section 8 Level Your Dryer see section 5 For side or bottom exhaust see section 9 SO0A436P009_RevO Pub 31 16228 Installation Instructions Minimum Clearance Other Than Alcove or Closet Installation Minimum clearance to combustible surfaces and for air opening are 0 in clearance both sides and 1 in rear Consideration must be given to provide adequate clearance for installation and service PREPARING FOR INSTALLATION OF NEW DRYER TIP Install your dryer before installing your washer This will allow better access when installing dryer exhaust REMOVING LINT FROM WALL EXHAUST OPENING e Remove and discard existing plastic or metal foil transition duct and replace with UL listed transition duct INTERNAL DUCT OPENING CHECK THAT EXHAUST HOOD DAMPER OPENS AND CLOSES FREELY Tilt the dryer sideways and remove the foa
9. Use exposed to water and or weather and Care Book for future reference Save these instructions Installers Be sure to leave these instructions with e Before the old dryer is removed from service or discarded the customer remove the dryer door e Service information and the wiring diagram are located in the control console e Do not allow children on or in the appliance Close super NOTE Installation and service of this dryer a A a i wa HO pudnee ane requires basic mechanical and electrical skills e Install the dryer where the temperature is above 50 F for It is your responsibility to contact a qualified satisfactory operation of the dryer control system installer to make the electrical connections Read these instructions completely and carefully TOOLS YOU MATERIALS YOU WILL NEED WILL NEED 4 DIA METAL DUCT 3 aa RECOMMENDED ee pail OM e DUCT f lt a sie Wo DRYER POWER CORD i n 2 GLASSES KIT NOT PROVIDED FLAT BLADE SCREWDRIVER 4 DIA FLEXIBLE METAL SEMI RIGID OR WITH DRYER UL LISTED TRANSITION DUCT 4 SPRING UL RATED IF NEEDED CLAMPS 2 KIT MVC OI INCLUDES 2 ELBOWS a N a g WITH 3 OR 4 PRONGS PHILLIPS SCREWDRIVER P O LB IDENTIFY THE PLUG DDD 3 4 STRAIN TYPE AS PER THE SS 4 DIA FLEXIBLE METAL FOIL TYPE eg eee BEFORE PURCHASING UL LISTED TRANSITION DUCT LINE CORD IF NEEDED Prepare the Area and Exhaust for Installation of New Step 8 Check the Operation of the Power
10. to the mobile home structure See EXHAUST INFORMATION section 3 amp 4 The vent MUST NOT be terminated beneath a mobile or manufactured home The vent duct material MUST BE METAL Do not use sheet metal screws or other fastening devices which extend into the interior of the exhaust vent See section 2 for electrical connection information Installation Instructions 9 DRYER EXHAUST TO RIGHT LEFT OR ADDING NEW DUCT BOTTOM CABINET FIXING HOLE AX WARNING BEFORE PERFORMING THIS EXHAUST INSTALLATION BE SURE TO DISCONNECT THE DRYER FROM ITS ELECTRICAL SUPPLY PROTECT YOUR HANDS AND ARMS FROM SHARP EDGES WHEN WORKING INSIDE THE CABINET BE SURE TO WEAR GLOVES PORTION A RIGHT OR LEFT SIDE EXHAUST Reconnect the cut portion A of the duct to the blower housing Make sure that the shortened duct is aligned with the tab in the base Use the screw saved previously to secure the duct in place through the tab on the appliance base ADDING ELBOW AND DUCT FOR EXHAUST TO LEFT OR RIGHT SIDE OF CABINET e Preassemble 4 elbow with 4 duct Wrap duct tape around DESIRED joint KNOCKOUT e Insert duct assembly elbow first through the side opening ONE ONLY and connect the elbow to the dryer internal duct adea Tebon aeaiee kokon CAUTION Be sure not to pull or damage the etach and remove the bottom right or left side knockout as i ae desired Remove the screw inside the dryer exhaust duct and electrical wire
11. HOWEVER IF FLEXIBLE DUCTING IS USED IT MUST BE UL LISTED METAL NOT PLASTIC STANDARD REAR EXHAUST Vented above floor level ELBOW HIGHLY RECOMMENDED RECOMMENDED CONFIGURATION TO MINIMIZE EXHAUST BLOCKAGE ELBOW HIGHLY RECOMMENDED NOTE ELBOWS WILL PREVENT DUCT KINKING AND COLLAPSING 5 LEVELING AND STABILIZING YOUR DRYER Stand the dryer upright near the final location and adjust the 4 leveling legs at the corners to ensure that the dryer is level from side to side and front to rear LEVEL LEVEL terns 4 LEVELING LEGS Installation Instructions Exhausting CONNECTING THE DRYER TO HOUSE VENT RIGID METAL TRANSITION DUCT e For best drying performance a rigid metal transition duct is recommended e Rigid metal transitions ducts reduce the risk of crushing and kinking UL LISTED FLEXIBLE METAL SEMI RIGID TRANSITION DUCT e f rigid metal duct cannot be used then UL listed flexible metal semi rigid ducting can be used Kit WX08X10077 e Never install flexible metal duct in walls ceilings floors or other enclosed spaces e Total length of flexible metal duct should not exceed 8 feet 2 4m e For many applications installing elbows at both the dryer and the wall is highly recommended see illustrations below Elbows allow the dryer to sit close to the wall without kinking and or crushing the transition duct maximizing drying performance
12. Installation Electric Dryer Instructions 09 Questions or Installation Call 1 800 GECARES US or Visit our Web site at www GEAppliances com US PEDESTALS FOR DRYERS Q comes with individual installation instructions WA R N N G RISK OF FIRE Three models available SBSD227F e To reduce the risk of severe injury or death follow all installation instructions SBSD107H BSD137H Clothes dryer installation must be performed by a qualified installer Install the clothes dryer according to these instructions and in accordance with local codes B E FO R F YO U B EG l N This dryer must be exhausted to the outdoors Use only 4 rigid metal ducting for exhausting the clothes dryer to the outdoors IMPORTANT save these instructions for local DO NOT install a clothes dryer with flexible plastic ducting materials inspector s use If flexible metal semi rigid or foil type duct is installed it must be UL listed and installed in accordance with the instructions found in Connecting The e IMPORTANT Observe all governing codes and Dryer To House Vent on page 5 of this manual Flexible venting materials ordinances are known to collapse be easily crushed and trap lint These conditions will e Note to Installer Be sure to leave these instructions with obstruct dryer airflow and increase the risk of fire the customer Do not install or store this appliance in any location where it could be e Note to Customer Keep these instructions with your
13. a common duct with a kitchen exhaust system A combination of grease and lint creates a potential fire hazard Do not use duct longer than specified in the exhaust length table Longer ducts can accumulate lint creating a potential fire hazard Never install a screen in or over the exhaust duct This will cause lint to accumulate creating a potential fire hazard Do not assemble ductwork with any fasteners that extend into the duct These fasteners can accumulate lint creating a potential fire hazard Do not obstruct incoming or exhausted air Provide an access for inspection and cleaning of the exhaust system especially at turns and joints Exhaust system shall be inspected and cleaned at least once a year THIS DRYER COMES READY FOR REAR EXHAUSTING IF SPACE IS LIMITED USE THE INSTRUCTIONS IN SECTION 9 TO EXHAUST DIRECTLY FROM THE SIDES OR BOTTOM OF THE CABINET STANDARD REAR EXHAUST Vented at floor level For straight line installation connect the dryer exhaust to the external exhaust hood using duct tape or clamp EXTERNAL DUCT OPENING DUCT TAPE OR DUCT CLAMP 4 METAL DUCT CUT TO PROPER LENGTH DUCT TAPE OR DUCT CLAMP Pull the vent protection bracket out until XN it stops and let it rest on the floor The VENT PROTECTION bracket prevents the unit from moving too Y BRACKET ig close to the wall and crushing the rear vent LO y NOTE WE STRONGLY RECOMMEND SOLID METAL EXHAUST DUCTING
14. artially fastened screw to be used as a hook Partially fasten a screw to the uppermost screw hole Hook the door on the partially fastened screw Fasten the hinge by installing the other 4 screws and tightening the partially fastened screw above Partially 7 Inserted Screw ig VAE ea Tighten All l R Screws DA T amp SERVICING b 0 AX WARNING LABEL ALL WIRES PRIOR i 7 TO DISCONNECTING WHEN SERVICING o CONTROLS WIRING ERRORS CAN CAUSE 9 IMPROPER AND DANGEROUS OPERATION AFTER SERVICING INSTALLATION SST For replacement parts and other information refer to Owner s Manual for servicing phone numbers 22 Switch the strike bracket and its cover to the opposite side by removing the screws then reinstall both on the opposite side MOVE STRIKE BRACKET 21 Using a putty Knife or any other flat tool remove the 5 plastic screw caps located on the dryer where the door will be installed and install them on the opposite side 0 O 0 O O lt ANA ROUGH IN DIMENSIONS 12
15. ation confirms your right to protection under the terms of your warranty www GEAppliances com US For Questions on Installation Call 1 800 626 2003 US or 1 800 361 3400 Canada 500A436P009 Pub 31 16228 REVERSING THE DOOR SWING IMPORTANT NOTES e Read the instructions all the way through before starting Handle parts carefully to avoid scratching paint Set screws down by their related parts to avoid using them in the wrong places Provide a non scratching work surface for the doors Normal completion time to reverse the door swing is 30 60 minutes IMPORTANT Once you begin do not move the cabinet until door swing reversal is completed These instructions are for changing the hinges from the right side to the left side if you ever want to switch them back to the right side follow these same instructions and reverse all references to the left and right TOOLS YOU WILL NEED v Cresent Wrench Adjustable S Phillips Head Screwdriver Putty Knife or Thin Blade Screwdriver DOOR PARTS Hinge Assembly Plastic Cover lt Nut 8 2 Washer 2 Large Tapping Tapping Machine Screw 10 6 Screw 8 2 Screw 8 6 Installation Instructions BEFORE YOU START 4 Lay the door down on a soft protected flat surface so that the inner part faces upward door resting on the handle side 1 Unplug the dryer from its electrical outlet 5 Remove the 6 large tapping screws 10
16. e lint creating a potential fire hazard The correct exhaust installation is YOUR RESPONSIBILITY Problems due to incorrect installation are not covered by the warranty Remove and discard existing plastic or metal foil transition duct and replace with UL listed transition duct The MAXIMUM ALLOWABLE duct length and number of bends of the exhaust system depends upon the type of duct number of turns the type of exhaust hood wall cap and all conditions noted below The maximum exhaust length for rigid metal duct is shown in the table below EXHAUST LENGTH RECOMMENDED MAXIMUM LENGTH Exhaust Hood Types Use only for short Se orate TE 4 pi Metal Metal 90 Feet 60 Feet 60 Feet 45 Feet 45 Feet 55 Feet 35 Feet 25 Feet No of 90 Elbows 0 25 Feet 15 Feet EXHAUST SYSTEM CHECKLIST HOOD OR WALLCAP e Terminate in a manner to prevent back drafts or entry of birds or other wildlife e Termination should present minimal resistance to the exhaust air flow and should require little or no maintenance to prevent clogging e Never install a screen in or over the exhaust duct This could cause lint build up e Wall caps must be installed at least 12 in above ground level or any other obstruction with the opening pointed down SEPARATION OF TURNS For best performance separate all turns by at least 4 ft of straight duct including distance between last turn and exhaust hood TURNS OTHER THAN
17. m shipping pads by pulling at the sides and breaking them away from the dryer legs Be sure to remove all of the foam pieces around the legs ELECTRICAL CONNECTION INFORMATION A WARNING TO REDUCE THE RISK OF FIRE ELECTRICAL SHOCK AND PERSONAL INJURY e DO NOT USE AN EXTENSION CORD OR AN ADAPTER PLUG WITH THIS APPLIANCE Dryer must be electrically grounded in accordance with local codes and ordinances or in the absence of local codes in accordance with the NATIONAL ELECTRICAL CODE ANSI NFPA NO 70 ELECTRICAL REQUIREMENTS This dryer must be connected to an individual branch circuit protected by the required time delay fuses or circuit breakers A four or three wire single phase 120 240V or 120 208V 60Hz 30 amp circuit is required GROUNDING INSTRUCTIONS This dryer must be connected to a grounded metal permanent wiring system or an equipment grounding conductor must be run with the circuit conductors and connected to the equipment grounding terminal on the appliance CONNECTING DRYER USING 4 WIRE CONNECTION MUST BE USED FOR MOBILE HOME INSTALLATION NOTE Since January 1 1996 the National Electric Code requires that new constructions utilize a 4 wire connection to an electric dryer REMOVE GROUND PGREN TA AND DISCARD KEEP GREN Tn GROUND f HOT WIRE RELOCATE GREEN GROUND SCREW HERE Se pen GREEN OR X STRAIN RELIEF BRACKET HOT RECOGNIZED WIRE STRAIN RELIEF NS 4 10 AWG MINIMUM COPPER
18. s inside the dryer when save Pull the duct out of the dryer inserting the duct FIXING HOLE pN m Pepe ay BE ADDED TO sa p EXHAUST CAN LEFT OR RIGHT SIDE Cut the duct as shown and keep portion A DUCT TAPE TAB LOCATION e Apply duct tape as shown on the joint between the dryer BEND TAB internal duct and the elbow DUCT A r a roe IN UP 45 a S W ae TAPE QD as CAUTION Pa Internal duct joints must be secured with tape otherwise Through the rear opening locate the tab in the middle of the they may separate and cause appliance base Lift the tab to about 45 using a flat blade asalet hazara screwdriver 6 y A Installation Instructions ADDING ELBOW FOR EXHAUST THROUGH BOTTOM OF CABINET e Insert the elbow through the rear opening and connect it to the dryer internal duct e Apply duct tape on the joint between the dryer internal duct and elbow as shown on page 7 CAUTION Internal duct joints must be secured with tape otherwise they may separate and cause a safety hazard ADDING COVER PLATE TO REAR OF CABINET KIT WE1M454 Connect standard metal elbows and ducts to complete the exhaust system Cover back opening with a plate Kit WE1M454 available from your local service provider Place dryer in final location AX WARNING NEVER LEAVE THE BACK OPENING WITHOUT THE PLATE TO REGISTER YOUR DRYER CALL TOLL FREE 1 888 269 1192 Prompt registr
Download Pdf Manuals
Related Search
Related Contents
LG 60PH6700 Energy Guide : Free Download, Borrow, and Streaming : Internet Archive HP-UX 11i versión 3 de Marzo de 2013 Notas y cambios importan medSim 300B - Blue Panther s.r.o. Smart System Mortero albañileria XG extra-grueso Geovision GV-MFD320 Samsung Multifunktions farvelaserprinter C2670FW Brugervejledning Atlantis Land A03-S1501 OnePower 1501 Copyright © All rights reserved.