GateWay Fax Systems Easy-Fax 90si User's Manual
Contents
1. Output 10dBm SELECT OUTPUT increment level SELECT OUTPUT 9dBm increment level SELECT 3 times until OUTPUT 6dBm increment level NEXT until OUTPUT 6dBm save level SELECT OUTPUT 6dBm previous menu SELECT NETWORK CONFIG modem output NEXT until NETWORK CONFIG previous menu SELECT CHANGE CONFIG Network Config NEXT CHANGE CONFIG Modem Config SELECT MODEM CONFIG Trellis coding SELECT TRELLIS disabled enable Trellis SELECT TRELLIS enabled enable Trellis MENU standby display Gate Way Fax Systems Inc www gwfs com 1 877 951 9800 page 4 13 90si Reference Guide 1 3 AT amp T Lucent General Dynamics SDD 1900 Objective To set Secure Data Mode for 9 6 Kbps Full Duplex Synchronous 8 Data Bits While On or Off Hook READY on or off Press Display MENU MAIN MENU Secure Data SELECT Ex SD 9 6 H ASYNC 8 2 4 Full Duplex NEXT until 9 6 Full Duplex SELECT Ex SD 9 6 F ASYNC 8 async NEXT SD 9 6 F ASYNC 8 syne SELECT SD 9 6 F SYNC 8 previous menu MENU On Hook Push Ready Objective To set MODEM OUTPUT to 6 dBm and CONFIG to TRELLIS 1 While On Hook and with Master CIK inserted Press Display MENU MAIN MENU Secure Data NEXT until MAIN MENU Change Config SELECT CHANGE CONFIG Security Config NEXT until CHANGE CONFIG Network Config SELECT NETWORK CONFIG Common Rining NEXT NETWORK CONFIG Modem Output SELECT MODEM OUTPUT Output 10d
2. the 90si power up sequence Before power is supplied to the unit both LED s will be extinguished When power is initially applied the green POWER LED will flash intermittently indicating that a self test is in progress Once self test is successfully completed the green POWER LED will illuminate The 90si is now in the ready state 2 2 Communication Errors If an error occurs during a reception or transmission of a fax the red FAULT LED will illuminate This indicates that a communications error has occurred The unit will still operate The red FAULT LED will go out after 90 seconds or once a new transmission begins 2 3 System Errors Flashing green and red LED s indicate that the 90si has detected an internal failure during self test at power up or during normal operation of the unit If this occurs press the white RESET button located on the right side of the unit This will restart the 90si and should return it to the ready state green POWER LED on red FAULT LED off If it does not depress the RESET button a second time If this is ineffective unplug the unit from the wall wait a moment and plug it back in 2 4 Contact GFS Customer Service If all of these steps fail to return the unit to a ready state contact Gateway Fax Systems Customer Service Toll Free at 1 877 951 9800 or 757 312 9800 via e mail at help gwfs com or via the web at http www gwfs com Our service staff will get you back on line prompt
3. 0si The Press column indicates which button on the secure telephone should be pressed The Display column indicates what the responding display will show The first line indicates the state of the secure telephone before proceeding 1 1 AT amp T Security Plus Objective To set Secure Data Mode for 4 8 Kbps Full Duplex Synchronous While On or Off Hook Press Display Program Program Mode 3 6 Operation Complete Sets Synchronous 3 4 Operation Complete Sets 4 8 Kbps Full Duplex 3 0 SD 48 FDX SYNC Displays new configuration Program Standby display GateWay Fax Systems Inc www gwfs com 1 877 951 9800 page 3 13 90si Reference Guide 1 2 AT amp T Lucent and General Dynamics 1100 Objective To set Secure Data Mode for 9 6 Kbps Full Duplex Synchronous While On or Off Hook Press Display MENU MAIN MENU Secure Voice NEXT MAIN MENU Secure Data SELECT Ex SD 9 6 FDX ASYNC 2 4 Full Duplex NEXT until 9 6 Full Duplex SELECT Async NEXT Sync SELECT SD 9 6 FDX SYNC previous menu MENU standby display Objective To set MODEM OUTPUT to 6 dBm and CONFIG to TRELLIS 1 While On Hook and with Master CIK inserted Press Display MENU MAIN MENU Secure Voice NEXT until MAIN MENU Change Config SELECT CHANGE CONFIG Security Config NEXT until CHANGE CONFIG Network Config SELECT NETWORK CONFIG Common Rining NEXT NETWORK CONFIG Modem Output SELECT MODEM OUTPUT
4. Bm SELECT OUTPUT increment level SELECT OUTPUT 9dBm increment level SELECT 3 times until OUTPUT 6dBm increment level NEXT until OUTPUT 6dBm save level SELECT OUTPUT 6dBm previous menu SELECT NETWORK CONFIG modem output NEXT until NETWORK CONFIG previous menu SELECT CHANGE CONFIG Network Config NEXT CHANGE CONFIG Modem Config SELECT MODEM CONFIG Trellis coding SELECT TRELLIS disabled enable Trellis SELECT TRELLIS enabled enable Trellis MENU standby display Gate Way Fax Systems Inc www gwfs com 1 877 951 9800 page 5 13 90si Reference Guide 14 GE RCA 2400 Objective To set Secure Data Mode for 2 4 Kbps Full Duplex Synchronous While On Hook to permanently change set up Press Display PROGRAM RCA STU III Type I SET UP back of unit Do You Want To Set term Options YES Do You Want To Set Standard Options NO TONE Dialing in ON OFF Change Comm Mode FULL HALF DUX Change Remote Capability is DISABLED Configure Data Port Example Data Mode 2400 ASYNC Change until Data Mode 2400 SYNC Change lines enabled display PROGRAM SAVE the CHANGES beep Changes SAVED Press YES to GO ON SET UP back of unit RCA STU III Type I While Off Hook to check set up and or change set up for THIS call ONLY Press Display MENU Comm Mode FULL HALF DUX Change NO Do You Want To Set Local Volume Configure Data Port for THIS Call ONLY Y
5. ES Ex Data Mode 2400 ASYNC Change until Data Mode 2400 SYNC Change This Call 2400 SYNC WITHOUT EC Press YES 7 current call status displayed GateWay Fax Systems Inc www gwfs com 1 877 951 9800 page 6 13 90si Reference Guide 1 5 GE 9600 A S S Objective To set Secure Data Mode for 9 6 Kbps Full Duplex Synchronous While On Hook to permanently change set up Press Display MENU DELETE GE STU III Type I then View KSD or ID NO Configure Terminal YES Control is Local Change Dialing Mode Tone Change Communication Mode Full Duplex Change Initial Voice Rate Voice 4800 Change Ex Data Mode 4800 ASYNC EC OFF Change Data ASYNC Change Data SYNC Change Data 4800 Change Data 9600 Change Data is 9600 SYNC EC OFF Change MENU DELETE standby display While Off Hook to check set up and or change set up for THIS call ONLY Press Display MENU DELETE NONSECURE Comm Mode FDX Change NO NONSECURE Voice 4800 Change Ex Data Mode 4800 ASYNC EC OFF Change YES Data ASYNC Change Data SYNC Change Data 4800 Change Data 9600 Change Data is 9600 SYNC EC OFF Change MENU DELETE standby display Gate Way Fax Systems Inc www gwfs com 1 877 951 9800 page 7 13 90si Reference Guide 1 6 Motorola SECTEL 1000 1500 Objective To set Secure Data Mode for 2 4 9 6 Kbps Full D
6. Easy Fax 90si Secure Facsimile Gateway Reference Guide GateWay Fax Systems Inc Virginia USA Toll Free 1 877 951 9800 Email help gwfs com http www gwfs com Revision 3 3 7 January 2005 1 0 2 0 3 0 90si Reference Guide CONTENTS Configuring your STU III for the 90si 1 1 AT amp T Security Plus 1 2 AT amp T Lucent and General Dynamics 1100 1 1 3 AT amp T Lucent General Dynamics 1900 SDD 1 1 4 GE RCA 2400 1 5 GE 9600 1 6 Motorola SECTEL 1000 1500 1 7 Motorola SECTEL MMT 1500 1 8 L 3 Communications STE 90si Status LED s 2 1 Power up 2 2 Communications Errors 2 3 System Errors 2 4 Contact GFS Customer Service Glossary of Secure Facsimile Terms PODMIDAUNWAYW WF 11 11 11 11 11 12 1 GateWay Fax Systems Inc would like to gratefully acknowledge the contribution of ETR Technical Services 336 698 9358 for providing the MODEM configuration procedure for the ATT 1100 And 1910 GateWay Fax Systems Inc www gwfs com 1 877 951 9800 page 2 13 90si Reference Guide 1 0 Configuring your STU III for the 90si The most common cause of 90si operational problems are attributed to not having the STU III s Secure Data port configured for Synchronous operation The following sections provide step by step instructions for configuring various secure telephones for Synchronous operation as well as setting speed and duplex to provide optimum performance with the 9
7. ax Systems Inc www gwfs com 1 877 951 9800 page 13 13
8. epress the MODEM button until 9 6 is displayed GateWay Fax Systems Inc www gwfs com 1 877 951 9800 page 9 13 90si Reference Guide 1 8 L 3 Communications STE Objective To set Secure Data Mode for 9 6 Kbps Synchronous For STE s with software V2 3 or earlier While On Hook Press Display MODE SECURE DATA A9 6 Asynchronous 9 6 Kbps CHANGE Secure Data Asynchronous CHANGE Secure Data Synchronous Sets Synchronous SCROLL Ex 2 4 Kbps SCROLL until 9 6 Kbps MODE blank display standby For STE s with software V2 4 and later While On Hook Press Display MODE SECURE SIGNALING MODE STE STU SCROLL SECURE DATA STU SECURE VOICE CHANGE SECURE DATA A9 6 Asynchronous 9 6 Kbps CHANGE Secure Data Asynchronous CHANGE Secure Data Synchronous Sets Synchronous SCROLL Ex 2 4 Kbps SCROLL until 9 6 Kbps MODE blank display standby Note that to permanently set the Secure Data mode the handset must be on hook GateWay Fax Systems Inc www gwfs com 1 877 951 9800 page 10 13 90si Reference Guide 2 0 90si Status LED s There are two LED s located on the front panel of the 90si The following three sections explain what the various LED states indicate 2 1 Power up Note Before applying power to the 90si make sure that all cables are securely connected and that your commercial fax device is in Auto Receive Fax mode and answers on 1 or 2 rings There are a series of LED indications during
9. ly GateWay Fax Systems Inc www gwfs com 1 877 951 9800 page 11 13 90si Reference Guide 3 0 Glossary of Secure Facsimile Terms Listed below are definitions of words and terms used in the 90si User s and Reference Guides Broadcast A signaling option in the Mil Std 161 mode in which the transmitting device does not look for any acknowledgements during a fax transmission Commercial Fax Device A Commercial Off The Shelf COTS standard Group III fax machine or computer based fax device Dual Mode A 90si configuration which allows the local fax machine to communicate with both secure and commercial fax machines FEC Forward Error Correction An option available in the Mil Std 161 mode that can decrease errors in fax transmission over noisy communication lines Note that STU s provide clean communication lines therefore eliminating the need for FEC Handshake A signaling option in the Mil Std 161 mode in which the transmitting fax device looks for acknowledgements during a fax transmission Mil Std 161 The SECDEF mandated military standard protocol for digital data transmission between fax devices Mil Std 161 is compatible with NATO s STANAG 5000 protocols Off Hook The state created on a telephone line when a telephone handset is picked up One Touch Key A feature on a fax machine that allows designated buttons to be programmed to go Off Hook and automatically dial a telephone number In the case of the 90si we reco
10. mmend that you program one of your fax s one touch keys to dial a 1 and designate it the Secure Start key Public Fax A document that does not contain sensitive or secret information and therefore need not be transmitted in a secure manner Ricoh Compatibility A set of digital protocols for communication between secure fax devices These protocols allow the 90si to be backwards compatible with older secure fax machines SDD Secure Data Device An SDD is a data only version of secure telephone Secure Data Mode A STU III s secure data mode encrypts confidential or classified information to be transmitted and received over standard telephone lines It is this mode that secure faxes are transmitted using Secure Fax A secure fax is a document that contains confidential or classified information that must be transmitted in a secure manner Secure Fax Device A specially manufactured fax device that includes the interface and protocols necessary to communicate over secure telephones such as the STU III STE Secure Telephone Equipment New secure telephone for use by the US Government STU IIB Secure Telephone Unit Generation Two Version B NATO version of STU III GateWay Fax Systems Inc www gwfs com 1 877 951 9800 page 12 13 90si Reference Guide STU III Secure Telephone Unit Generation Three STU IIIA Secure Telephone Unit Generation Three Version A US Secure telephone that can connect with a STU IIB Gate Way F
11. uplex Synchronous While Off Hook and in CLEAR mode Press PRGM SCROLL until PRGM While On Hook Press PRGM SCROLL x SCROLL until PRGM Note Display Ex DATA 2400 ASYNC DATA SYNCHRONOUS PRGM current call status displayed Display PRGM enunciator in display PLEASE WAIT and then for COMSEC TO SET OPTIONS PRESS SCROLL TO CONTINUE Ex DATA 2400 ASYNC TO CHANGE DATA SYNCHRONOUS TO CHANGE PRGM current call status displayed Make sure that HD DOES NOT appear in the display If it does press the HALF DUPLEX button to make it disappear If your telephone is black in color make sure that 9 6 is displayed If either 2 4 or 4 8 are displayed depress the MODEM button until 9 6 is displayed GateWay Fax Systems Inc www gwfs com 1 877 951 9800 page 8 13 90si Reference Guide 1 7 Motorola SECTEL MMT 1500 Objective To set Secure Data Mode for 9 6 Kbps Full Duplex Synchronous While On Hook Press Display PRGM PRGM enunciator in display SCROLL until USER OPTIONS TO SELECT PRESS SCROLL TO CONTINUE SCROLL until Ex DATA 2400 ASYNC TO CHANGE DATA SYNCHRONOUS TO CHANGE PRGM PRGM current call status displayed Note Make sure that HD DOES NOT appear in the display If it does press the HALF DUPLEX button to make it disappear If your telephone is black in color make sure that 9 6 is displayed If either 2 4 or 4 8 are displayed d
Download Pdf Manuals
Related Search
Related Contents
Sistema NCQ – Inventario the great outdoors by Minka Lavery 9273-277 Instructions / Assembly Avaya Bogen UL Listed (UUMW) Flush-Mounted Loudspeaker Enclosure User's Manual Aplicações do raciocínio estratégico na análise da carreira na visão Can Filter Group 340425 Instructions / Assembly Dynamic 3000 - rincoultrasonics.de Cliquez pour consulter le Mode d`emploi Chine 取 扱 説 明 書 a visão dos pais em relação a importância da Copyright © All rights reserved.