1. This is a pulse of energy on the power line Spikes can have voltages as high as 6000 volts Though they are usually of very short duration the energy they contain can be considerable enough to damage sensitive solid state components in audio and computer equipment Spikes can also foul switch contacts and degrade wiring insulation They are an unavoidable component of electric power They are caused unpredictably by electric motors switching on or off on the premises or outside utility company maintenance operations lightning strikes and other factors Spikes also called surges or transients are absorbed by special components in the Merit Series to provide safe voltage levels to protect your equipment RFI EMI INTERFERENCE Noise from RFI Radio Frequency Interference or EMI Electro Magnetic Interference involves lower voltages and less energy than is found in spikes but it is continuous rather than transient in nature It is not likely to cause damage but it can certainly be annoying producing static in audio circuits snow on video screens or garbled data in computers Noise can be introduced into AC lines by nearby radio transmitters certain kinds of lighting electric motors and other sources Because noise occurs at higher frequencies than the 50 or 60 Hz AC line it can be effectively reduced through use of low pass filtering ONE YEAR LIMITED WARRANTY Furman Sound Inc having its principal place
2. incidental special or consequential damages Manufacturer s employees or representatives ORAL OR OTHER WRITTEN STATEMENTS DO NOT CONSTITUTE WARRANTIES shall not be relied upon by Purchaser and are not a part of the contract for sale or this limited warranty This Limited Warranty states the entire obligation of Manufacturer with respect to the Product If any part of this Limited Warranty is determined to be void or illegal the remainder shall remain in full force and effect SERVICE Before returning any equipment for repair please be sure that it is adequately packed and cushioned against damage in shipment and that it is insured We suggest that you save the original packaging and use it to ship the product for servicing Also please enclose a note giving your name address phone number and a description of the problem NOTE All equipment being returned for repair must have a Return Authorization RA Number To get an RA Number please call the Furman Service Department 707 763 1010 ext 121 Please display your RA Number prominently on the front of all packages INTRODUCTION Thank you for purchasing a Furman Merit Series Power Distributor or Conditioner and congratulations on your choice The Merit Series power conditioners feature excellent surge protection as well as RFI EMI filtration SAFETY INFORMATION To obtain best results from your Furman Merit Series unit please read this manual carefully bef
3. of business at 1997 South McDowell Blvd Petaluma CA 94954 Manufacturer warrants its Merit Series the Product as follows Manufacturer warrants to the original Purchaser of the Product that the Product sold hereunder will be free from defects in material and workmanship for a period of one year from the date of purchase The Purchaser of the product is allowed fifteen days from the date of purchase to complete warranty registration by mail or on line at the Furman website If the Product does not conform to this Limited Warranty during the warranty period as herein above specified Purchaser shall notify Manufacturer in writing of the claimed defects If the defects are of such type and nature as to be covered by this warranty Manufacturer shall authorize Purchaser to return the Product to the Furman factory or to an authorized Furman repair location Warranty claims should be accompanied by a copy of the original purchase invoice showing the purchase date this is not necessary if the Warranty Registration was completed either via the mailed in warranty card or on line website registration Shipping charges to the Furman factory or to an authorized repair location must be prepaid by the Purchaser of the product Manufacturer shall at its own expense furnish a replacement Product or at Manufacturer s option repair the defective Product Return shipping charges back to Purchaser will be paid by Manufacturer TH
4. 3 1310 Web www furmansound com E mail info furmansound com FURMAN PURIFY YOUR POWER 111904 D M 10 Features Ten convenient outlets Rack mountable chasis 15 amp rating with circuit breaker One year limited warranty M 8 Features RFI EMI Filtering Surge amp Spike Protection Eight rear panel outlets and one front panel outlet 15 amp rating with circuit breaker One year limited warranty M 8L Features RFI EMI Filtering Surge amp Spike Protection Eight rear panel outlets and one front panel outlet 15 amp rating with circuit breaker One year limited warranty Two retractable incandescent light fixtures with dimmer control for convenient rack illumination M 8D Features RFI EMI Filtering Surge amp Spike Protection Eight rear panel outlets and one front panel outlet 15 amp rating with circuit breaker One year limited warranty Two retractable incandescent light fixtures with dimmer control for convenient rack illumination Digital Voltmeter displays incoming line voltage M 8D Light Switch Voltmeter Circuit Breaker Power Switch Ce tia omy En ee ee te ee Ee ey TT TOD OW Ve ee T o O OR MIN MAX POWER CONDITIONER Dimmer Control Rack Lights Additional Switched Outlet M 8L Light Switch Circuit Breaker Power Switch G ouu aN a i R A E a L a ee Ee ee t LC t t C C C A POWER CONDITIONER MIN MAX eA O LOO AT o TD IUT T a A a O S eee Dimmer Con
5. E FOREGOING IS IN LIEU OF ALL OTHER WARRANTIES EXPRESS OR
6. SPECIFICATIONS Current rating 15 amps 1800 watts at 120 VAC Line Cords 6 ft captive 14 AWG with 3 conductor Edison Plug Lamps if present 2 x 5 watts AC Voltmeter if present Range 60 to 150 VAC accuracy 2 VAC Operating Voltage 90 to 140 VAC Spike Protection Modes M 8 M 8L M 8D Line to neutral Spike Clamping Voltage M 8 M 8L M 8D 188 Vpk 3 000 amps 133 VAC RMS Maximum surge current M 8 M 8L M 8D 4 500 amps Noise attenuation M 8 M 8L M 8D Transverse mode Greater than 50 dB 1 to 100 MHz Mechanical Dimensions M 8 M 8L M 8D 1 75 H x 19 W x 7 5 D Dimensions M 10 1 75 H x 19 W x 3 96 D Weight 5 Ibs 2 3 kg Construction Steel chassis black painted Power Consumption M 8 6 watts M 8L 14 watts M 8D 14 watts M 10 O watts Safety Agency Listings TUV TUV C MERIT SERIES MERIT SERIES MERIT SERIES MERIT SERIES n n ON OFF RACK LIGHTS ON OFF RACK LIGHTS A MIN MAX DIMMER DIMMER owner s manual MERIT SERIES Power Londitioners POWER CONDITIONER POWER CONDITIONER POWER CONDITIONER POWER DISTRIBUTION ON OFF J AC 120V 15A SWITCHED OUTLET POWER ON OFF j AC 120V 15A SWITCHED OUTLET POWER ON OFF j AC 120V 15A SWITCHED OUTLET POWER ON FURMAN Furman Sound Inc 1997 South McDowell Blvd Petaluma California 94954 6919 USA Phone 707 763 1010 Fax 707 76
7. fire or injury damaged cords and cables should be replaced immediately 6 Clean your Merit Series unit with a damp cloth only Do not use solvents or abrasive cleaners Never pour liquid on or into the unit 7 Your Merit Series unit should be serviced by qualified service personnel when e The power supply cord or the plug has been frayed kinked or cut e Objects have fallen or liquid has spilled into the unit e The unit has been exposed to rain or other moisture e The unit does not appear to operate normally e The unit has been dropped or the enclosure has been damaged e The retractable lights have failed 8 Your Merit Series unit requires that a safety ground be present for proper operation Any attempt to operate the unit without a safety ground is considered improper operation and could invalidate the warranty 9 Do not attempt to service your Merit Series unit beyond what is described in this manual All other servicing should be referred to qualified service personnel FEATURES M 10 The M 10 power distributor is a convenient way to power your rack It provides 10 outlets on its rear panel and carries a 15 amp rating with a circuit breaker M 8 The M 8 power conditioner provides 9 switched outlets for powering equipment It not only protects anything plugged into it from spikes and surges but also has a built in AC noise filter to rid the system of RFI EMI interference This allows equipment to fu
8. nction better and last longer M 8L In addition to features of the M 8 the M 8L features incandescent rack lights A dimmer control for the rack lights allows the user to adjust the level of illumination or simply switch the lights off The M 8L has a master switch for all outlets that glows red when the power is on The front panel circuit breaker can be quickly and easily reset should the unit be overloaded The M 8L also features 5 5 feet of 14 gauge heavy duty power cable M 8D In addition to all the features of the M 8 and M 8L the M 8D offers a laboratory precision digital meter that displays incoming voltage in 1 volt steps The voltmeter s accuracy is 2 volts The M 8D has a master switch for all outlets that glows red when the power is on The front panel circuit breaker can be quickly and easily reset should the unit be overloaded The M 8D also features 5 5 feet of 14 gauge heavy duty power cable OPERATION Retractable Rack Lights and Dimmer Control The M 8L and M 8D utilize a dimmer control for the two retractable front panel light tubes The dimmer knob controls the brightness of both light fixtures Turn it clockwise to increase brightness turn it counterclockwise to decrease brightness When the lights are not in use we recommend turning the racklight s switch to off to better maximize the life of the bulbs Digital Voltmeter M 8D Furmanss digital voltmeter continually measures incoming v
9. oltages within a typical tolerance of 2VAC It should be noted that the voltage reading is incoming No adjustment should be necessary on these units NOTE The Merit Series units do not compensate for high or low line voltage If you frequently move your rack to different locations derive power from generators use long extension cords travel internationally or are in an area prone to brownouts you may benefit from the use of one of Furman s AC Line Voltage Regulators On Off Rocker Switch This 15 amp capacity power switch is specifically designed to stand up to the enormous high inrush current demands of many Power Amplifiers Additionally the semi transparent rocker lights when switched to the ON position TROUBLESHOOTING GUIDE 1 Symptom No power to the AC outlets Possible Cause Circuit breaker has tripped due to excessive load Action Needed Remove one piece of equipment from the Merit Series unit and push the square re set tab into the Circuit breaker bezel 2 Symptom No power to the AC outlets Possible Cause Either the AC outlet to which your Merit Series device is connected has no AC voltage present or the unit has been subjected to a sustained voltage in excess of 400 Volts Action Needed Plug the Merit Series unit into an AC receptacle where AC voltage is present If the problem persists the protection circuit may be damaged and require factory service DEFINITIONS SPIKE
10. ore using WARNING To reduce the risk of electrical shock do not expose this equipment to rain or moisture Dangerous high voltages are present inside the enclosure Do not remove the covers Refer servicing to qualified personnel only The lightning flash with an arrowhead symbol is intended to alert the user to the presence of un insulated dangerous voltage within the product s enclosure that may be of sufficient magnitude to constitute a risk of electric shock IMPORTANT SAFETY INSTRUCTIONS Please read prior to installation 1 Please read and observe all safety and operating instructions before installing your Merit Series unit Retain these instructions for future reference 2 Your Merit Series unit should not be used near water for example near a bathtub washbowl kitchen sink laundry tub in a wet basement near a swimming pool etc 3 Do not place your Merit Series unit near heat sources such as radiators heat registers stoves or other appliances that produce heat 4 The Merit Series units should only be connected to a 120 VAC 60Hz 15 amp grounded electrical outlet Do not defeat the ground or change polarization of the power plug 5 Route the power cord and other cables so that they are not likely to be walked on tripped over or stressed Pay particular attention to the condition of the cords and cables at the plugs and the point where they exit your Merit Series unit To prevent risk of
11. trol Rack Lights Additional Switched Outlet Additional Switched Outlet Circuit Breaker MERIT SERIES POWER CONDITIONER Power Switch M 10 Circuit Breaker MERIT SERIES POWER DISTRIBUTION IMPLIED INCLUDING BUT NOT LIMITED TO THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE Manufacturer does not warrant against damages or defects arising out of improper or abnormal use of handling of the Product against defects or damages arising from improper installation against defects in products or components not manufactured by Manufacturer or against damages resulting from such non Manufacturer made products or components This warranty shall be cancelable by Manufacturer at its sole discretion if the product is modified in any way without written authorization from Furman Sound This warranty also does not apply to Products upon which repairs have been affected or attempted by persons other than pursuant to written authorization by Manufacturer THIS WARRANTY IS EXCLUSIVE The sole and exclusive obligation of Manufacturer shall be to repair or replace the defective Product in the manner and for the period provided above Manufacturer shall not have any other obligation with respect to the Products or any part thereof whether based on contract tort strict liability or otherwise Under no circumstances whether based on this Limited Warranty or otherwise shall Manufacturer be liable for

Download Pdf Manuals