Home

Fujitsu SPARC M3000 User's Manual

image

Contents

1. Server class Model name Entry level SPARC Enterprise M3000 Midrange SPARC Enterprise M4000 SPARC Enterprise M5000 High end SPARC Enterprise M8000 SPARC Enterprise M9000 Text Conventions vi This manual uses the following fonts and symbols to express specific types of information C120 E360 06EN Fonts symbols Meaning Preface Examples AaBbCc123 What you type when contrasted with on screen computer output This font represents the example of command input in the frame XSCF adduser jsmith AaBbCc123 The names of commands files and directories on screen computer output This font represents the example of command output in the frame XSCF showuser p User Name jsmith Privileges useradm auditadm Italic font Indicates the name ofa reference manual See the XSCF Reference Manual no Indicates names of chapters sections items buttons or menus See Chapter 2 Setup of the RCI for Operation Prompt Notations The prompt notations used in this manual are as follows Shell Prompt Notations XSCF XSCF gt C shell machine names C shell super user machine name Bourne shell and Korn shell Bourne shell and Korn shell super user OpenBoot PROM ok Syntax of the Command Line Interface CLI The command syntax is described below Command syntax The command syntax is as
2. Example Replacing the RCI I O unit at the RCI address 003002ff XSCF setrci c replaceconfig 003002ff The command completed successfully In lt address gt specify the RCI address eight digit hexadecimal number obtained by RCI address confirmation To confirm an RCI replacement setting 1 Execute the setrci 8 command to display the RCI status XSCF gt setrci c stat HOST address 000102ff Active LIST address pwr alm I F Sys phase ctgry dev cls sub cls tm out 000101ff OFF ACT host 0001 0b 2 003001ff OFF ACT disk 0400 04 003002ff OFF ACT u disk 0400 04 003003ff OFF ACT u disk 0400 04 The command completed successfully On the list confirm that ACT is displayed in the I F column of the RCI I O unit at the RCI address specified for the RCI replacement setting C120 E360 06EN 2 11 CHAPTER 2 Setup of the RCI for Operation 2 6 2 6 1 2 6 2 2 6 3 RCI Setup for Replacement of an RCI Base Cabinet RCI setup flow RCI setup for replacement of an RCI host contains the following steps Replacing an RCI host Confirming RCI initialization Connecting an RCI cable Making an RCI address setting ak N Making an RCI replacement setting Note Perform this RCI setup work for each RCI host to be replaced Replacing an RCI host Remove the T branch connector together with the RCI cable from the RCI host to be replaced
3. OPTIONS The following options are supported c exrdy Sets the EXRDY monitoring timeout period of the specified external RCI address power control devices Set the EXRDY monitoring timeout period in time units of minutes for fime If 0 1s specified EXRDY monitoring is disabled If time 1s omitted the EXRDY monitoring timeout period is displayed c opcalldisp Displays the status of the operator call signals of the specified external power control devices c opcallon Sets the operator call signals of the specified external power control RCI address devices on Setting is made for the devices corresponding to the bits of callNo callNo that contain 1 c opcalloff Sets the operator call signals of the specified external power control RCI address devices off Setting is made for the devices corresponding to the bits of callNo callNo that contain 1 h Displays usage statement When used with other options or operands an error occurs OPERANDS The following operands are supported RCI address Specifies a target RCI address A value in any of the following ranges can be specified for RCI address 003001ff 00307fff 007001ff 00707fff time Sets the EXRDY monitoring timeout period when c exrdy is specified in units of minutes Any decimal integer number ranging from 0 to 85 can be specified callNo Specifies operator call information A two digit hexadecimal number can b
4. Be ese 1 3 Power on wait kl ka 22 a a xd RE ka a d x e E a a kal Y wes ae 1 3 Asynchronous RCI monitoring 1 3 1 3 RCI Connection Scheme cai o kk kK KK x a RE SEE 1 4 Basic configuration rar ed KK KK KK KK KK et o e KK 1 4 Cluster configuration kK kK kK kK KK KK KK KK KK e 1 5 Duplicated configuration 1 5 CHAPTER 2 Setup of the RCI for Operation 2 1 2 1 Overview of RCI Setup 2 1 2 2 RCI Setup for Initial Installation 2 2 2 2 1 RClsetupflow 2 2 2 2 2 Confirming RCI initialization 2 2 To confirm RCI initialization 2 2 2 2 3 Connecting RCI Cables 2 44 sas ena eek yes hk a Res KK KK KK ann 2 3 2 2 4 Making an RCI address setting 2 3 To specify an RCI address 2 3 To confirm an RCI address 2 3 2 2 5 Making an RCI construction setting 2 3 To make an RCI construction setting 2 4 To confirm an RCI construction setting 2 4 2 3 RCI Setup for Addition of an RCI I O Unit 2 4 2 3 1 RECESS t p TOW 352i a rn En At nike 2 4 2 3 2 Connecting an R
5. Etats Unis et dans d autres pays Les produits portant les marques SPARC sont bas s sur une architecture d velopp e par Sun Microsystems Inc SPARC64 est une marques d pos e de SPARC International Inc utilis e sous le permis par Fujitsu Microelectronics Inc et Fujitsu Limited L interface d utilisation graphique OPEN LOOK et Sun a t d velopp e par Sun Microsystems Inc pour ses utilisateurs et licenci s Sun reconna t les efforts de pionniers de Xerox pour la recherche et le d veloppement du concept des interfaces d utilisation visuelle ou graphique pour l industrie de l informatique Sun d tient une license non exclusive de Xerox sur l interface d utilisation graphique Xerox cette licence couvrant galement les licenci s de Sun qui mettent en place l interface d utilisation graphique OPEN LOOK et qui en outre se conforment aux licences crites de Sun Droits du gouvernement am ricain logiciel commercial Les utilisateurs du gouvernement am ricain sont soumis aux contrats de licence standard de Sun Microsystems Inc et de Fujitsu Limited ainsi qu aux clauses applicables stipul es dans le FAR et ses suppl ments Avis de non responsabilit les seules garanties octroy es par Fujitsu Limited Sun Microsystems Inc ou toute soci t affili e de l une ou l autre entit en rapport avec ce document ou tout produit ou toute technologie d crit e dans les pr sentes correspondent aux garanties express ment stipul es dans
6. The furnishing of this document to you does not give you any rights or licenses express or implied with respect to the product or technology to which it pertains and this document does not contain or represent any commitment of any kind on the part of Fujitsu Limited or Sun Microsystems Inc or any affiliate of either of them This document and the product and technology described in this document may incorporate third party intellectual property copyrighted by and or licensed from suppliers to Fujitsu Limited and or Sun Microsystems Inc including software and font technology Per the terms of the GPL or LGPL a copy of the source code governed by the GPL or LGPL as applicable is available upon request by the End User Please contact Fujitsu Limited or Sun Microsystems Inc This distribution may include materials developed by third parties Parts of the product may be derived from Berkeley BSD systems licensed from the University of California UNIX is a registered trademark in the U S and in other countries exclusively licensed through X Open Company Ltd Sun Sun Microsystems the Sun logo Java Netra Solaris Sun Ray Answerbook2 docs sun com OpenBoot and Sun Fire are trademarks or registered trademarks of Sun Microsystems Inc or its subsidiaries in the U S and other countries Fujitsu and the Fujitsu logo are registered trademarks of Fujitsu Limited All SPARC trademarks are used under license and are registered trademark
7. added cabinet can use RCI functions Make an RCI expansion setting on the added RCI host Note Before beginning this RCI setup work confirm that AC cables are connected to all RCI units Note To make an RCI expansion setting for an RCI unit equipped with a main line switch set the main line switch to the ON position To make an RCI expansion setting 1 Execute the setrci 8 command and make an RCI expansion setting XSCF setrci c addconfig The command completed successfully To confirm an RCI expansion setting 2 8 1 Execute the setrci 8 command to display the RCI status XSCF gt setrci c stat HOST address 000102ff Active LIST address pwr alm I F sys phase tgry dev cls sub cls tm out 000101ff OFF ACT host 0001 0b u 000102ff OFF ACT host 0001 0b 003001ff OFF ACT disk 0400 04 The command completed successfully Confirm that the displayed LIST contents include the added RCI host For details on LIST contents see Chapter 3 Command Reference C120 E360 06EN 2 5 2 5 1 2 5 2 2 5 RCI Setup for Replacement of an RCI I O Unit RCI Setup for Replacement of an RCI I O Unit RCI setup flow RCI setup for replacement of an RCI VO unit contains the following steps 1 Confirming an RCI address 2 Replacing an RCI I O Unit 3 Making an RCI replacement setting Note Perform this RCI setup work for each RCI I O unit to be r
8. and replace the RCI host with a new one Do not connect the removed T branch connector to the new RCI host at this time Confirming RCI initialization Before connecting an RCI cable again to a new RCI host confirm that RCI settings have been initialized To confirm RCI initialization 1 Execute the setrci 8 command to display the RCI status XSCF gt setrci c stat HOST address 000f7fff Inactive The command completed successfully Confirm that the address value is 000f7fff initial address value If RCI settings have not been initialized perform the next step C120 E360 06EN 2 6 RCI Setup for Replacement of an RCI Base Cabinet 2 Execute the setrci 8 command to initialize RCI settings XSCF setrci c init The command completed successfully 2 6 4 Connecting an RCI cable Connect the removed T branch connector together with the RCI cable to the new RCI host Note Always do Confirming RCI initialization before reconnecting the RCI cable to the RCI host 2 6 5 Making an RCI address setting Assign an RCI address to the new RCI host after replacement Make an RCI address setting on the new RCI host IMPORTANT gt Specify the same RCI address as that assigned to the old RCI host To specify an RCI address 1 Execute the setrci 8 command and specify an RCI address Example Specifying the RCI address 000102ff for the XSCF XSCF gt setrci c set 2 he comma
9. follows A variable that requires input of a value must be enclosed in lt gt An optional element must be enclosed in A group of options for an optional keyword must be enclosed in and delimited by A group of options for a mandatory keyword must be enclosed in and delimited by C120 E360 06EN The command syntax is shown in a box Example XSCF gt showuser a Fujitsu Welcomes Your Comments If you have any comments or requests regarding this manual or if you find any unclear statements in the manual please state your points specifically on the form at the following URL For Users in U S A Canada and Mexico http www computers us fujitsu com www support servers shtml support servers For Users in Other Countries SPARC Enterprise contact http www fujitsu com global contact computing sparce index html viii C120 E360 06EN Contents Prelace cunda Waa dak xu K a mew EE aT XS i CHAPTER 1 RCI Overview 8 kk kk kk kk kk kk kk kk kk kk kk kk mn 1 1 1 1 TRGI Features M Run 1 1 RCI redundancy only for the high end system 1 2 1 2 e E Eo ss oscar EA a at Pat T OG e UE ws 1 2 RCI network status monitoring 1 2 Control of power supply to RCI I O units 1 2 Interlocking mechanism for power supply to domains 1 2 Facility controles rias RS e tn BARS PEU
10. le contrat de licence r gissant le produit ou la technologie fourni e SAUF MENTION CONTRAIRE EXPRESS MENT STIPUL E DANS CE CONTRAT FUJITSU LIMITED SUN MICROSYSTEMS INC ET LES SOCI T S AFFILI ES REJETTENT TOUTE REPR SENTATION OU TOUTE GARANTIE QUELLE QU EN SOIT LA NATURE EXPRESSE OU IMPLICITE CONCERNANT CE PRODUIT CETTE TECHNOLOGIE OU CE DOCUMENT LESQUELS SONT FOURNIS EN L TAT EN OUTRE TOUTES LES CONDITIONS REPR SENTATIONS ET GARANTIES EXPRESSES OU TACITES Y COMPRIS NOTAMMENT TOUTE GARANTIE IMPLICITE RELATIVE LA QUALIT MARCHANDE L APTITUDE UNE UTILISATION PARTICULIERE OU A L ABSENCE DE CONTREFACON SONT EXCLUES DANS LA MESURE AUTORIS E PAR LA LOI APPLICABLE Sauf mention contraire express ment stipul e dans ce contrat dans la mesure autoris e par la loi applicable en aucun cas Fujitsu Limited Sun Microsystems Inc ou l une de leurs filiales ne sauraient tre tenues responsables envers une quelconque partie tierce sous quelque th orie juridique que ce soit de tout manque gagner ou de perte de profit de probl mes d utilisation ou de perte de donn es ou d interruptions d activit s ou de tout dommage indirect sp cial secondaire ou cons cutif m me si ces entit s ont t pr alablement inform es d une telle ventualit LA DOCUMENTATION EST FOURNIE EN L ETAT ET TOUTES AUTRES CONDITIONS DECLARATIONS ET GARANTIES EXPRESSES OU TACITES SONT FORMELLEMENT EXCLUES DANS LA MESURE AUTORISEE PAR LA L
11. the RCI status XSCF gt setrci c stat HOST address 000102ff Active LIST address pwr alm I F Sys phase ctgry dev cls sub cls tm out 000101ff OFF ACT host 0001 0b 000102ff OFF ACT host 0001 0b u 003001ff OFF ACT u disk 0400 04 The command completed successfully Confirm that the displayed LIST contents include the replacement RCI host For details on LIST contents see Chapter 3 Command Reference C120 E360 06EN 2 15 CHAPTER 3 Command Reference 3 1 setrci NAME setrci configure or display the environment of the remote cabinet interface RCI SYNOPSIS setrci c stat setrci c init 5 RC network setrci c set host no setrci c initconfig s RCI network setrci c addconfig s RC network setrci c replaceconfig RCI address setrci c ledon RCI address setrci c ledoff setrci c idpin setrci h e DESCRIPTION The setrci 8 command configures or displays information that accompanies the initial setting and maintenance of the RCI environment The following can be set or displayed stat Displays the status of the RCI network init Initializes the RCI setting Initialization is only performed for the host that executes the command If there are other hosts connecting to the RCI initialization must be performed for each host set Sets an RCI address Use this specification when the RCI setting has been initialized After the setting c
12. 1ff OFF ACT host 0001 0b 003001ff OFF ACT disk 0400 04 The command completed successfully Confirm that the displayed LIST contents include the connected RCI I O unit For details on LIST contents see Chapter 3 Command Reference C120 E360 06EN 2 5 CHAPTER 2 Setup of the RCI for Operation 2 4 RCI Setup for Addition of an RCI Base Cabinet 2 4 1 RCI setup flow RCI setup for addition of an RCI host contains the following steps Confirming RCI initialization Connecting an RCI cable Making an RCI address setting Bona Making an RCI expansion setting 2 4 2 Confirming RCI initialization Before connecting an RCI cable to an RCI host confirm that RCI settings have been initialized To confirm RCI initialization 1 Execute the setrci 8 command to display the RCI status XSCF gt setrci c stat HOST address 000f 7fff Inactive The command completed successfully Confirm that address is 000f7fff initial address value If RCI settings have not been initialized perform the next step 2 Execute the setrci 8 command to initialize RCI settings XSCF gt setrci c init The command completed successfully 2 4 3 Connecting an RCI cable Connect an RCI cable to the RCI host to be added 1 Insert a T branch connector and an RCI cable into the existing set of connections of RCI cables 2 6 C120 E360 06EN 2 4 RCI Setup for Addition of an RCI Base Cabinet 2 Connect t
13. 3 1 setrci EXAMPLES EXAMPLE 1 Makes the first RCI setting on the first host in an M3000 M4000 M5000 server C120 E360 06EN 3 5 CHAPTER 3 Command Reference 3 6 XSCF gt setrci c init RCI 0 The command completed successfully RCI 1 The command completed successfully XSCF gt setrci c set 1 RCI 0 The command completed successfully RCI 1 The command completed successfully XSCF setrci c initconfig RCI 0 The command completed successfully RCI 1 The command completed successfully XSCF setrci c stat RCI 0 HOST address 000101ff Active LIST address pwr alm I F sys phase ctgry dev cls 000101ff ON ACT host 0001 003001ff ON ACT disk 0400 The command completed successfully RCI 1 HOST address 004101ff Active LIST address pwr alm I F sys phase ctgry dev cls 004101ff ON ACT host 0001 The command completed successfully sub cls tm out 0b x 10s sub cls tm out 0b x C120 E360 06EN 3 1 setrci EXAMPLE 2 Makes the first RCI setting on the first host in an M8000 M9000 server XSCF setrci c init The command completed successfully XSCF gt setrci c set 1 The command completed successfully XSCF setrci c initconfig The command completed successfully XSCF setrci c stat RCI 0 HOST address 000101ff Active LEST address pwr alm I F sys phase ctgry dev cls sub cls tm out 000101ff ON A
14. 8000 M9000 Servers RCI User s C120 E360 Guide SPARC Enterprise M3000 Server Product Notes Go to the Web SPARC Enterprise M4000 M 5000 Servers Product Notes Go to the Web SPARC Enterprise M8000 M9000 Servers Product Notes Go to the Web External I O Expansion Unit Product Notes C120 E456 SPARC Enterprise M3000 M4000 M5000 M8000 M9000 Servers Glossary C120 E514 SPARC Enterprise PRIMEQUEST Common Installation Planning Manual C120 H007 1 Manuals on the Web The latest versions of all the SPARC Enterprise Series manuals are available at the following websites Global Site http www fujitsu com sparcenterprise manual Japanese Site http primeserver fujitsu com sparcenterprise manual Note Product Notes is available on the website only Please check for the recent update on your product Documentation CD For the Documentation CD please contact your local sales representative SPARC Enterprise M3000 Server Documentation CD C120 E541 SPARC Enterprise M4000 M5000 Servers Documentation CD C120 E365 SPARC Enterprise M8000 M9000 Servers Documentation CD C120 E364 Manual included on the Enhanced Support Facility x x CD ROM disk Remote maintenance service Book Title Manual Code Enhanced Support Facility User s Guide for REMCS C112 B067 Manual man page provided in the system XSCF man page Note The man page can be referenced on the XSCF Shell and it provides the same content as the SPARC Enterprise
15. CI Cable noc cedere u ET KK RET 2 5 2 3 8 Making an RCI expansion setting 2 5 To make an RCI expansion setting 2 5 To confirm an RCI expansion setting 2 5 2 4 RCI Setup for Addition of an RCI Base Cabinet 2 6 24 1 RClsetupflow 2 6 2 4 2 Confirming RCI initialization 2 6 To confirm RCI initialization 2 6 2 4 3 Connecting an RCI cable sede RR RE E ant 2 6 C120 E360 06EN ix Contents 2 44 Making an RCI address setting 2 7 To specify an RCI address 2 2 0 5 kK KK KK KK KK ee 2 7 To confirm the specified RCI address 2 7 2 45 Making an RCI expansion setting 2 8 To make an RCI expansion setting 2 8 To confirm an RCI expansion setting 2 8 2 5 RCI Setup for Replacement of an RCI I O Unit 2 9 25 4 IRCbsetup flow si si os xb re a Ce RO E kr 2 9 2 5 2 Confirming an RCI address ios stu EYES de eit Rt 2 9 To confirm an RCI address 2 9 To confirm the location of an RCI I O unit 2 10 2 5 3 Replacing an RCI VO Unit AA A AK KK KK KK RR RR KK KK IK 2 10 2 5 4 Making an RCI replacement sett
16. CT host 0001 0b 003001ff ON ACT disk 0400 10s The command completed successfully EXIT STATUS The following exit values are returned 0 Successful completion gt 0 An error occurred C120 E360 06EN 3 7 CHAPTER 3 Command Reference 3 2 setrcic NAME setrcic make the setting of an external power control device or display its status SYNOPSIS setrcic c exrdy RCI address time setrcic c opcalldisp RCI address setrcic c opcallon RC address callNo setrcic copcalloff RCI address callNo setrcic h e DESCRIPTION The setrcic 8 command makes the setting of an external power control device or displays its status The following can be set or displayed Multiple items cannot be set at a time exrdy Sets or displays the EXRDY monitoring timeout periods of the specified external power control devices If the setting is inconsistent with the external equipment wait time an error occurs opcalldisp Displays the status of the operator call signal of the specified external p power control devices opcallon Sets the operator call signals of the specified external power control devices on opcalloff Sets the operator call signals of the specified external power control devices off PRIVILEGES You must have platadm or fieldeng privileges to run this command Refer to setprivileges 8 for more information 3 8 C120 E360 06EN 3 2 setrcic
17. ES OF ANY KIND EXPRESS OR IMPLIED REGARDING SUCH PRODUCT OR TECHNOLOGY OR THIS DOCUMENT WHICH ARE ALL PROVIDED AS IS AND ALL EXPRESS OR IMPLIED CONDITIONS REPRESENTATIONS AND WARRANTIES INCLUDING WITHOUT LIMITATION ANY IMPLIED WARRANTY OF MERCHANTABILITY FITNESS FOR A PARTICULAR PURPOSE OR NON INFRINGEMENT ARE DISCLAIMED EXCEPT TO THE EXTENT THAT SUCH DISCLAIMERS ARE HELD TO BE LEGALLY INVALID Unless otherwise expressly set forth in such agreement to the extent allowed by applicable law in no event shall Fujitsu Limited Sun Microsystems Inc or any of their affiliates have any liability to any third party under any legal theory for any loss of revenues or profits loss of use or data or business interruptions or for any indirect special incidental or consequential damages even if advised of the possibility of such damages DOCUMENTATION IS PROVIDED AS IS AND ALL EXPRESS OR IMPLIED CONDITIONS REPRESENTATIONS AND WARRANTIES INCLUDING ANY IMPLIED WARRANTY OF MERCHANTABILITY FITNESS FOR A PARTICULAR PURPOSE OR NON INFRINGEMENT ARE DISCLAIMED EXCEPT TO THE EXTENT THAT SUCH DISCLAIMERS ARE HELD TO BE LEGALLY INVALID 5 cx A y Adobe PostScript C120 E360 06EN Copyright 2007 2008 FUJITSU LIMITED 1 1 Kamikodanaka 4 chome Nakahara ku Kawasaki shi Kanagawa ken 211 8588 Japon Tous droits r serv s Entr e et revue tecnical fournies par Sun Microsystems Incl sur des parties de ce mat riel Sun Microsystems Inc et Fuj
18. Guide C120 E348 SPARC Enterprise M8000 M9000 Servers Safety and Compliance Guide C120 E326 External I O Expansion Unit Safety and Compliance Guide C120 E457 SPARC Enterprise M4000 Server Unpacking Guide C120 E349 SPARC Enterprise M5000 Server Unpacking Guide C120 E350 SPARC Enterprise M8000 M9000 Servers Unpacking Guide C120 E327 SPARC Enterprise M3000 Server Installation Guide C120 E539 SPARC Enterprise M4000 M5000 Servers Installation Guide C120 E351 SPARC Enterprise M8000 M9000 Servers Installation Guide C120 E328 SPARC Enterprise M3000 Server Service Manual C120 E540 SPARC Enterprise M4000 M5000 Servers Service Manual C120 E352 SPARC Enterprise M8000 M9000 Servers Service Manual C120 E330 External I O Expansion Unit Installation and Service Manual C120 E329 SPARC Enterprise M3000 M4000 M5000 M8000 M9000 Servers RCI Build C120 E361 Procedure SPARC Enterprise M3000 M4000 M5000 M8000 M9000 Servers Administration C120 E331 Guide SPARC Enterprise M3000 M4000 M5000 M8000 M9000 Servers XSCF User s C120 E332 Guide SPARC Enterprise M3000 M4000 M5000 M8000 M9000 Servers XSCF C120 E333 Reference Manual SPARC Enterprise M4000 M5000 M8000 M9000 Servers Dynamic C120 E335 Reconfiguration DR User s Guide SPARC Enterprise M4000 M5000 M8000 M9000 Servers Capacity on Demand C120 E336 COD User s Guide C120 E360 06EN Preface Manual Book Titles Codes SPARC Enterprise M3000 M4000 M5000 M
19. I F RCI unit interface status ACT Valid state INACT Invalid state sys phase Operating state of the host connected to RCI One of the following is displayed power off Powered off panic In the panic state shdwn start Shutdown in progress shdwn cmplt Shutdown has completed dump cmplt Dump has completed booting System being started running System in operation Not support the status display host ctgry Category of the RCI unit One of the following is displayed Host unit disk rcic File unit External power control device linesw Line switch Other Other devices dev cls Device class of the RCI unit sub cls tm out no display Subdevice class of the RCI unit Idle monitoring timeout period of RCI Since it doesn t support the status is always displayed host causes an error to occur When c initconfig c addconfig or c init needs to be executed in the system power off status c replaceconfig is being executed or the setrcic 8 command is being executed do not execute the setrci 8 command on another When the setrci 8 command is executed set all RCI units that are connected to RCI into the power on state or standby state Executing the setrci 8 command on a model that does not support the RCI function C120 E360 06EN
20. M3000 M4000 M5000 M8000 M9000 Servers XSCF Reference Manual 5 Documentation and Support on the Web The latest information about other documents and the support for your server are provided on the websites C120 E360 06EN Note Preface Message Global Site http www fujitsu com sparcenterprise msg Japanese Site http primeserver fujitsu com sparcenterprise msg Firmware program You can download the latest files of firmware at the following websites Global Site http www fujitsu com sparcenterprise firmware Japanese Site http primeserver fujitsu com sparcenterprise download firmware The following files or document are provided Firmware program file XSCF Control Package XCP file XSCF extension MIB definition file XSCF Control Package XCP XCP is a package which has the control programs of hardware that configures a computing system The XSCF firmware and the OpenBoot M PROM firmware are included in the XCP file Fault Management MIB SUN FM MIB definition file http src opensolaris org source xref onnv onnv gate usr src lib fm libfmd snmp mibs 6 Solaris Operating System Related Manuals http docs sun com 7 Provided In firmware program CD For maintenance service for FEs gt Firmware program file XSCF Control Package XCP file XSCF extension MIB definition file 8 Information on Using the RCI function The manual does not contain an explanation of
21. OI APPLICABLE Y COMPRIS NOTAMMENT TOUTE GARANTIE IMPLICITE RELATIVE A LA QUALITE MARCHANDE A L APTITUDE A UNE UTILISATION PARTICULIERE OU A L ABSENCE DE CONTREFACON C120 E360 06EN Preface This manual describes the Remote Cabinet Interface RCI function on SPARC9 Enterprise series servers This manual is intended for users specifically system management maintenance administrators However when carrying out actual operations authorized service personnels do it Be sure to also read the SPARC Enterprise M3000 M4000 M5000 M8000 M 9000 Servers XSCF User s Guide and other manuals referenced in this manual This section includes Audience Audience Glossary Structure and Contents of this Manual SPARC Enterprise Mx000 Servers Documentation Abbreviated References to Other Documents Models Text Conventions Prompt Notations Syntax of the Command Line Interface CLI Fujitsu Welcomes Your Comments This manual is intended for users specifically SPARC Enterprise system management maintenance administrators Moreover the system administrator is required to have the following knowledge Glossary Solaris M Operating System Solaris OS and Unix command SPARC Enterprise system and basic knowledge of XSCF For the terms used in the SPARC Enterprise Mx000 Servers Documentation refer to the SPARC Enterprise M3000 M4000 M5000 M8000 M9000 Servers Glossary Structure and Contents of this Manual This manual is or
22. cO FUJITSU SPARC Enterprise M3000 M4000 M5000 M8000 M9000 Servers C120 E360 06EN C120 E360 06EN SPARC Enterprise M3000 M4000 M5000 M8000 M9000 Servers RCI User s Guide co FUJITSU Copyright 2007 2008 FUJITSU LIMITED 1 1 Kamikodanaka 4 chome Nakahara ku Kawasaki shi Kanagawa ken 211 8588 Japan All rights reserved Sun Microsystems Inc provided technical input and review on portions of this material Sun Microsystems Inc and Fujitsu Limited each own or control intellectual property rights relating to products and technology described in this document and such products technology and this document are protected by copyright laws patents and other intellectual property laws and international treaties The intellectual property rights of Sun Microsystems Inc and Fujitsu Limited in such products technology and this document include without limitation one or more of the United States patents listed at http www sun com patents and one or more additional patents or patent applications in the United States or other countries This document and the product and technology to which it pertains are distributed under licenses restricting their use copying distribution and decompilation No part of such product or technology or of this document may be reproduced in any form by any means without prior written authorization of Fujitsu Limited and Sun Microsystems Inc and their applicable licensors if any
23. dy been completed This work can be performed while an existing domain is running 2 3 1 RCI setup flow RCI setup for addition of an RCI I O unit contains the following steps 1 Connecting an RCI cable 2 Making an RCI expansion setting 2 4 C120 E360 06EN 2 3 RCI Setup for Addition of an RCI I O Unit 2 3 2 Connecting an RCI cable 1 Insert a T branch connector and an RCI cable into the existing set of connections of RCI cables 2 Connect the T branch connector to the RCI I O unit to be added 2 3 3 Making an RCI expansion setting The added RCI I O unit must be connected to the RCI network An RCI address is automatically set for the added RCI I O unit so that the unit can use RCI functions An RCI expansion setting can be made only once from an arbitrary RCI host Note Before beginning this RCI setup work confirm that AC cables are connected to all RCI units Note To make an RCI expansion setting for an RCI unit equipped with a main line switch set the main line switch to the ON position To make an RCI expansion setting 1 Execute the setrci 8 command and make an RCI expansion setting XSCF gt setrci c addconfig The command completed successfully To confirm an RCI expansion setting 1 Execute the setrci 8 command to display the RCI status XSCF gt setrci c stat HOST address 000101ff Active LIST address pwr alm I F Sys phase ctgry dev cls sub cls tm out 00010
24. e and explanation are described to the following table Code Explanation 00 Detected the duplicate RCI address 01 RCI address of current unit is not configured or false 02 Detected the duplicate RCI address of RCI host or detected the undefined RCI address 03 RCI address of current unit is not configured 04 Over maximum entry of RCI table 05 Detected anomaly in RCI table receiving 06 Detected anomaly in RCI table sending 07 Receiving status check from undefined RCI device 08 Detected the loss of RCI master 09 0a Detected anomaly of RCI table Synchronous time out of RCI table 0b Synchronous retry out of RCI table 0c Detected anomaly of RCI table 0d Failed the version check of RCI table 0e 0f Detected anomaly of RCI table Detected anomaly in synchronous with RCI Neuron chip 20 Detected the duplicate RCI address in RCI I O unit Expansion file unit External power controller 30 Detected the duplicate RCI address in RCI I O unit Line selector switch fd RCI construction cannot be constructed or it was cancelled fe Other RCI unit is constructing the RCI network ff RCI setup procedure is false C120 E360 06EN 4 1 CHAPTER 4 Error Status 4 2 setrcic error status When the RCI construction by the setrcic command ends abnormally and Operation fai
25. e specified EXTENDED DESCRIPTION When the setrci 8 command or setrcic 8 command is being executed on another host in the RCI network do not execute the setrcic 8 command When the setrcic 8 command is executed set all RCI units that are connected to RCI into the power on state or standby state Executing the setrcic 8 command on a model that does not support the RCI function causes an error to occur C120 E360 06EN 3 9 CHAPTER 3 Command Reference 3 10 EXAMPLES EXAMPLE 1 Makes the setting of external power control XSCF gt setrcic c exrdy 003001ff 10 The command completed successfully XSCF gt setrcic c exrdy 003001ff address 003001ff exrdy 10 min The command completed successfully XSCF gt setrcic c opcallon 003001ff Oc The command completed successfully XSCF gt setrcic c opcalldisp 003001ff address 003001ff callNo 0c The command completed successfully XSCF gt setrcic c opcalloff 003001ff Oc The command completed successfully XSCF gt setrcic c opcalldisp 003001ff address 003001ff callNo 00 The command completed successfully EXIT STATUS The following exit values are returned 0 Successful completion gt 0 An error occurred C120 E360 06EN CHAPTER 4 Error Status 4 1 setrci error status When the RCI construction by the setrci command ends abnormally and Operation failed error status XX is displayed the displayed error status cod
26. eplaced Confirming an RCI address Confirm the RCI address or location of the RCI I O unit to be replaced To confirm an RCI address 1 Push the service pin of the RCI I O unit to be replaced 2 Execute the setrci 8 command to display the address of the RCI I O unit whose service pin is pushed XSCF gt setrci c idpin RCI XXXX VER XX DATE XXXX XX XX XX XX XX The command completed successfully If the RCI I O unit to be replaced has failed and cannot make a transmission its RCI address cannot be confirmed by the above operation Perform the following operation to confirm the RCI address C120 E360 06EN 2 9 CHAPTER 2 Setup of the RCI for Operation 2 5 3 2 10 3 Execute the setrci 8 command to display a list of connected RCI units XSCF setrci c stat HOST address 000102ff Active LIST address pwr alm I F sys phase tgry dev cls sub cls tm out 000101ff OFF ACT host 0001 0b 003001ff OFF ACT disk 0400 04 003002ff OFF INACT disk 0400 04 003003ff OFF ACT u disk 0400 04 The command completed successfully On the list INACT is displayed in the I F column of the RCI VO unit that cannot make a transmission to the RCI To confirm the location of an RCI I O unit If the RCI address of the target RCI I O unit is already known such as because of an error message the location of the RCI I O unit can be confirmed by specifying it
27. fore connecting an RCI cable to an RCI host confirm that RCI settings have been initialized To confirm RCI initialization 1 Execute the setrci 8 command to display the RCI status XSCF gt setrci c stat HOST address 000f7 fff Inactive The command completed successfully Confirm that address is 000f7fff initial address value If RCI settings have not been initialized perform the next step 2 Execute the setrci 8 command to initialize RCI settings XSCF gt setrci c init The command completed successfully 2 2 C120 E360 06EN 2 2 3 2 2 4 2 2 RCI Setup for Initial Installation Connecting RCI cables Connect RCI cables Connect RCI units in sequence with RCI cables and their T branch connectors Connect RCI terminating resistors to the T branch connectors at both ends of a set of RCI connections Making an RCI address setting Specify 000101ff as the RCI address for the first RCI host The RCI address must be unique in duplicate RCI networks To specify an RCI address 2 2 5 1 Execute the setrci 8 command and specify an RCI address Example Specifying the RCI address 000101ff for the XSCF XSCF gt setrci c set 1 he command completed successfully H To confirm an RCI address 1 Execute the setrci 8 command to display the RCI status XSCF gt setrci c stat HOST address 000101ff Inactive The comma
28. ganized as described below C120 E360 06EN Preface CHAPTER 1 RCI Overview This chapter gives an overview of the Remote Cabinet Interface RCI CHAPTER 2 Setup of the RCI for Operation This chapter describes setup information for use of the RCI CHAPTER 3 Command Reference This chapter describes the RCI command CHAPTER 4 Error Status This chapter describes the error status codes i C120 E360 06EN SPARC Enterprise Mx000 Servers Documentation The manuals listed below are provided for reference Preface Manual Book Titles Codes SPARC Enterprise M3000 Server Site Planning Guide C120 H030 SPARC Enterprise M4000 M5000 Servers Site Planning Guide C120 H015 SPARC Enterprise M8000 M9000 Servers Site Planning Guide C120 H014 SPARC Enterprise Equipment Rack Mounting Guide C120 H016 SPARC Enterprise M3000 Server Getting Started Guide C120 E536 SPARC Enterprise M4000 M5000 Servers Getting Started Guide C120 E345 SPARC Enterprise M8000 M9000 Servers Getting Started Guide C120 E323 SPARC Enterprise M3000 Server Overview Guide C120 E537 SPARC Enterprise M4000 M5000 Servers Overview Guide C120 E346 SPARC Enterprise M8000 M9000 Servers Overview Guide C120 E324 Important Safety Information for Hardware Systems C120 E391 SPARC Enterprise M3000 Server Safety and Compliance Guide C120 E538 SPARC Enterprise M4000 M5000 Servers Safety and Compliance
29. h a connection to the XSCF and use the XSCF shell The RCI is configured in the following types of setup RCI Setup for Initial Installation RCI Setup for Addition of an RCI I O Unit RCI Setup for Addition of an RCI Base Cabinet RCI Setup for Replacement of an RCI I O Unit RCI Setup for Replacement of an RCI Base Cabinet Each setup for RCI configuration is explained in the following manner Explanation 1 The explanation of each RCI setup begins with a description of the overall setup flow 2 Setup procedures are then explained with setting examples For detailed explanations and details on options of XSCF Shell commands see the man pages or Chapter 3 Command Reference This section does not explain in detail the connection between the XSCF and a PC or terminal and methods for logging in to the XSCF For details see the XSCF User 5 Guide C120 E360 06EN 2 1 CHAPTER 2 Setup of the RCI for Operation 2 2 RCI Setup for Initial Installation This section explains the procedure for initial RCI setup which assumes RCI settings have not been configured Note Perform this work when this system is not using any RCI I O unit 2 2 1 RCI setup flow RCI setup for initial installation contains the following steps Confirming RCI initialization Connecting RCI cables Making an RCI address setting 5 N Making an RCI construction setting 2 2 2 Confirming RCI initialization Be
30. he T branch connector to the RCI host to be added Note Always do Confirming RCI initialization before connecting an RCI cable to the RCI host 2 4 4 Making an RCI address setting Specify an RCI addresses in a range of 000102ff to 000120ff for the RCI host to be added The RCI address must be unique in the existing RCI network RCI addresses must be assigned in the order of 000102ff 000103 ff 000104ff and so on Specify the RCI address on the RCI host to be added To specify an RCI address 1 Execute the setrci 8 command and specify an RCI address Example Specifying the RCI address 000102ff for the XSCF SCF gt setrci c set 2 he command completed successfully gt lt H Specify a decimal number for the fifth and sixth digits of the target RCI address A decimal number in a range of 1 to 32 can be used To confirm the specified RCI address 1 Execute the setrci 8 command to display the RCI status XSCF gt setrci c stat HOST address 000102ff Inactive The command completed successfully Confirm that the address value is correct To correct the RCI address start again from RCI initialization C120 E360 06EN 2 7 CHAPTER 2 Setup of the RCI for Operation 2 4 5 Making an RCI expansion setting The added RCI host must be connected to the RCI network The RCI address of the added RCI host is synchronized with those of existing RCI hosts so that the
31. ing 2 11 To make an RCI replacement setting 2 11 To confirm an RCI replacement setting 2 11 2 6 RCI Setup for Replacement of an RCI Base Cabinet 2 12 2 0 1 RGL setup low s du kar ba ee Gee E ES 2 12 2 6 2 Replacing an RCI host loser an nl 2 12 2 6 3 Confirming RCI initialization 2 12 To confirm RCI initialization 2 12 2 6 4 Connecting an RCI cable 2220 RR a KK nt 2 13 2 65 Making an RCI address setting 2 13 To specify an RCI address 2 13 To confirm the specified RCI address 2 14 2 6 6 Making an RCI replacement setting 2 14 To make an RCI replacement setting 2 14 To confirm an RCI replacement setting 2 15 CHAPTER 3 Command Reference 3 1 SW RE LS sos stulte erPPIB Wiwuwwuse em abe asta bee Glee t ES as Pets 3 1 NAMES oro se cele N M beo ni foU A fece O ak 3 1 SYNOPSIS etes R2 shvan ri dadas 3 1 DESCRIPTION amp nsus targets nes same sets p M e 3 1 PRIVILEGES ne 2 ee tri dia e de Sat ea ats das 3 2 OPTIONS ueste EE A a ac 3 2 OPERANDS e tala ia Pees 3 3 EXTENDED DESCRIPTION 3 3 EXAMPLES A sawa ao ad ebat eese
32. initconfig or c addconfig must be executed initconfig Makes the RCI setting on the first host An RCI I O unit connected via RCI is searched for and found and then an RCI address is assigned C120 E360 06EN 3 1 CHAPTER 3 Command Reference addconfig Adds an RCI I O unit or host When an RCI I O unit is added the RCI I O unit newly connected to RCI is searched for and found and then an RCI address is assigned When a host is added it is also added to the RCI network c set must be executed beforehand on the added host to set the RCI address for the host replaceconfig Replaces an RCI I O unit or host When an RCI I O unit is replaced the specified RCI address is assigned to the substitute RCI I O unit When a host is replaced a substitute host is added to the RCI network after the information of the host to be replaced is deleted from the RCI network c set must be executed beforehand on the substitute host to set the RCI address for the host An RCI address cannot be specified when replacing a host ledoff Stops the blinking CHECK LED of an RCI I O unit This specification is used such as when the work for identifying an RCI I O unit is completed idpin Displays the RCI address of the RCI I O unit whose ID PIN has been pressed This specification is used when checking the RCI address of an RCI I O unit PRIVILEGES You must have platadm or fieldeng privileges to run
33. ion must be made together with c init c initconfig and c addconfig RCI 0 Specifies the RCI network on the 0 side RCI 1 Specifies the RCI network on the 1 side OPERANDS The following operands are supported RCI address Specifies a target RCI address A value in any of the following ranges can be specified for RCI address 003001ff 00307fff 007001ff 00707fff 002001ff 00207fff 006001ff 00607fff EXTENDED DESCRIPTION When c stat is specified the following states are displayed RCI x RCI network name address RCI address It is displayed as an eight digit hexadecimal number When the RCI address of the host has not been set the default value 00ff7fff is displayed Active Inactive RCI state Inactive means that the RCI is in the initial state and Active means that the RCI setting has been made Inactive The RCI is in the initial state Active The RCI setting has been made Mainte The mode switch is Service state When the RCI state is Active the following information is displayed after List address The address of the connected RCI unit pwr Power state of the RCI unit ON Powered on OFF Powered off alm Alarm state of the RCI unit x Normal state ALM Alarm state WRN Warning state C120 E360 06EN 3 3 CHAPTER 3 Command Reference
34. itsu Limited d tiennent et contr lent toutes deux des droits de propri t intellectuelle relatifs aux produits et technologies d crits dans ce document De m me ces produits technologies et ce document sont prot g s par des lois sur le copyright des brevets d autres lois sur la propri t intellectuelle et des trait s internationaux Les droits de propri t intellectuelle de Sun Microsystems Inc et Fujitsu Limited concernant ces produits ces technologies et ce document comprennent sans que cette liste soit exhaustive un ou plusieurs des brevets d pos s aux tats Unis et indiqu s l adresse http www sun com patents de m me qu un ou plusieurs brevets ou applications brevet es suppl mentaires aux tats Unis et dans d autres pays Ce document le produit et les technologies aff rents sont exclusivement distribu s avec des licences qui en restreignent l utilisation la copie la distribution et la d compilation Aucune partie de ce produit de ces technologies ou de ce document ne peut tre reproduite sous quelque forme que ce soit par quelque moyen que ce soit sans l autorisation crite pr alable de Fujitsu Limited et de Sun Microsystems Inc et de leurs ventuels bailleurs de licence Ce document bien qu il vous ait t fourni ne vous conf re aucun droit et aucune licence expresses ou tacites concernant le produit ou la technologie auxquels il se rapporte Par ailleurs il ne contient ni ne repr sente aucun engageme
35. led error status XX is displayed the displayed error status code and explanation are described to the following table Code Explanation 1 Detected an RCI transmission error 2 Terminated the command execution due to RCI busy Note 1 3 Internal error occurred in XSCF Note 2 Note 1 After a certain period of time re execute the setrcic command When this case reappears please contact our field engineer Note 2 Please contact our field engineer C120 E360 06EN cO FUJITSU
36. nd completed successfully H Specify a decimal number for the fifth and sixth digits of the target RCI address A decimal number in a range of 1 to 32 can be used C120 E360 06EN 2 13 CHAPTER 2 Setup of the RCI for Operation To confirm the specified RCI address 1 Execute the setrci 8 command to display the RCI status XSCF gt setrci c stat HOST address 000102ff Inactive The command completed successfully Confirm that the address value is correct To correct the RCI address start again from RCI initialization 2 6 6 Making an RCI replacement setting The new RCI host must be connected to the RCI network The RCI address of the new RCI host is synchronized with those of existing RCI hosts so that the new cabinet can use RCI functions An RCI replacement setting can be made on the new RCI host Note Before beginning this RCI setup work confirm that AC cables are connected to all RCI units Note To make an RCI replacement setting for an RCI unit equipped with a main line switch set the main line switch to the ON position To make an RCI replacement setting 1 Execute the setrci 8 command and make an RCI replacement setting XSCF setrci c replaceconfig The command completed successfully 2 14 C120 E360 06EN 2 6 RCI Setup for Replacement of an RCI Base Cabinet To confirm an RCI replacement setting 1 Execute the setrci 8 command to display
37. nd completed successfully Confirm that the address value is correct To correct the RCI address start again from RCI initialization Making an RCI construction setting Make an RCI network setting RCI addresses are automatically set for RCI I O units connected through the RCI so that the units can use RCI functions Note Before beginning this RCI setup work confirm that AC cables are connected to all RCI units C120 E360 06EN 2 3 CHAPTER 2 Setup of the RCI for Operation Note To make an RCI construction setting for an RCI unit equipped with a main line switch set the main line switch to the ON position To make an RCI construction setting 1 Execute the setrci 8 command and make an RCI construction setting XSCF setrci c initconfig The command completed successfully To confirm an RCI construction setting 1 Execute the setrci 8 command to display the RCI status XSCF setrci c stat HOST address 000101ff Active LIST address pwr alm I F sys phase ctgry dev cls sub cls tm out 000101ff OFF ACT host 0001 0b The command completed successfully Confirm that the displayed LIST contents include the connected RCI unit For details on LIST contents see Chapter 3 Command Reference 2 3 RCI Setup for Addition of an RCI I O Unit This section explains the setup procedure for adding an RCI I O unit to this system for which RCI setup for initial installation has alrea
38. nnections to RCI I O units RCI host VO unit RCI VO unit RCI cables are connected in sequence to respective units using T branch connectors RCI terminating resistors must be connected to the T branch connectors at both ends of a set of RCI connections Up to 32 RCIs including the RCI main unit can be connected Note that the maximum RCI cable length is 150 meters Use the repeater function of the external power controller to extend the cable length used and to increase the number of connected RCI units Note The external power controller is included in the number of RCI units 1 4 C120 E360 06EN 1 3 RCI Connection Scheme Cluster configuration Figure 1 2 shows a cluster connection pattern Figure 1 2 Cluster connections RCI host RCI host Up to 32 RCI hosts can be connected The cluster connection requirements such as the maximum cable length and the number of connectable RCI I O units are the same as the basic configuration requirements Note The repeater function of the external power controller cannot be used to increase the number of RCI base cabinets Duplicated configuration Figure 1 3 shows the connection pattern of a duplicated configuration Figure 1 3 Duplicated configuration RCI host RCI host RCI hosts can be constructed in a duplicated configuration only if their XSCF units are in a redundant configuration duplicated configuration Note Do not connect an expansi
39. nt de quelque type que ce soit de la part de Fujitsu Limited ou de Sun Microsystems Inc ou des soci t s affili es Ce document et le produit et les technologies qu il d crit peuvent inclure des droits de propri t intellectuelle de parties tierces prot g s par copyright et ou c d s sous licence par des fournisseurs Fujitsu Limited et ou Sun Microsystems Inc y compris des logiciels et des technologies relatives aux polices de caract res Par limites du GPL ou du LGPL une copie du code source r gi par le GPL ou LGPL comme applicable est sur demande vers la fin utilsateur disponible veuillez contacter Fujitsu Limted ou Sun Microsystems Inc Cette distribution peut comprendre des composants d velopp s par des tierces parties Des parties de ce produit pourront tre d riv es des syst mes Berkeley BSD licenci s par l Universit de Californie UNIX est une marque d pos e aux Etats Unis et dans d autres pays et licenci e exclusivement par X Open Company Ltd Sun Sun Microsystems le logo Sun Java Netra Solaris Sun Ray Answerbook2 docs sun com OpenBoot et Sun Fire sont des marques de fabrique ou des marques d pos es de Sun Microsystems Inc ou ses filiales aux Etats Unis et dans d autres pays Fujitsu et le logo Fujitsu sont des marques d pos es de Fujitsu Limited Toutes les marques SPARC sont utilis es sous licence et sont des marques de fabrique ou des marques d pos es de SPARC International Inc aux
40. on XSCF unit to an RCI network connected to a base XSCF unit C120 E360 06EN 1 5 CHAPTER 1 RCI Overview Figure 1 4 shows a connection pattern that connects both duplicated and unduplicated configurations Figure 1 4 Mixture of duplicated and unduplicated configurations RCI host RCI host The pattern can contain RCI I O units and RCI hosts that do not support a duplicated configuration Connect them to the duplicate system Connect RCI hosts that do not support a duplicated configuration to the 0 system If an RCI host that does not support a duplicated configuration were already connected RCI I O units would be connected to the 70 system Note When an RCI host of the duplicated configuration is connected with RCI hosts or RCI I O units that do not support a duplicated configuration it may fail to control the RCI host or the RCI I O unit on the 0 system in the following case When an XSCFU O0 failure generated an XSCF failover and the Active XSCF Unit switched to XSCFU 1 In this case maintenance work of XSCFU 0 becomes necessary 1 6 C120 E360 06EN CHAPTER 2 Setup of the RCI for Operation This chapter describes setup information for use of the RCI 2 1 Overview of RCI Setup The RCI can be set up as follows Note RCI setup as explained in this chapter is carried out by authorized service personnel Prepare a serially connected PC or a PC connected to the XSCF LAN specify its IP address establis
41. s RCI address and triggering blinking of its LED Execute the setrci 8 command to trigger blinking of the LED of the RCI I O unit at the specified RCI address Example Specifying the RCI address 003002ff XSCF setrci c ledon 003002ff The command completed successfully Locate the RCI I O unit whose LED is blinking Execute the setrci 8 command to stop the blinking LED of the RCI I O unit XSCF setrci c ledoff The command completed successfully Replacing an RCI I O Unit Remove the T branch connector together with the RCI cables from the RCI I O unit to be replaced Replace the RCI I O unit and connect the T branch connector and RCI cables to the new RCI VO unit C120 E360 06EN 2 5 RCI Setup for Replacement of an RCI I O Unit 2 5 4 Making an RCI replacement setting The added RCI I O unit must be connected to the RCI network The RCI address of the added RCI I O unit is synchronized with that of an existing RCI host so that the unit can use RCI functions An RCI expansion setting can be made only once from an arbitrary RCI host Note Before beginning this RCI setup work confirm that AC cables are connected to all RCI units Note To make an RCI expansion setting for an RCI unit equipped with a main line switch set the main line switch to the ON position To make an RCI replacement setting 1 Execute the setrci 8 command and make an RCI replacement setting
42. s of SPARC International Inc in the U S and other countries Products bearing SPARC trademarks are based upon architecture developed by Sun Microsystems Inc SPARC64 is a trademark of SPARC International Inc used under license by Fujitsu Microelectronics Inc and Fujitsu Limited The OPEN LOOK and Sun Graphical User Interface was developed by Sun Microsystems Inc for its users and licensees Sun acknowledges the pioneering efforts of Xerox in researching and developing the concept of visual or graphical user interfaces for the computer industry Sun holds a non exclusive license from Xerox to the Xerox Graphical User Interface which license also covers Sun s licensees who implement OPEN LOOK GUIs and otherwise comply with Sun s written license agreements United States Government Rights Commercial use U S Government users are subject to the standard government user license agreements of Sun Microsystems Inc and Fujitsu Limited and the applicable provisions of the FAR and its supplements Disclaimer The only warranties granted by Fujitsu Limited Sun Microsystems Inc or any affiliate of either of them in connection with this document or any product or technology described herein are those expressly set forth in the license agreement pursuant to which the product or technology is provided EXCEPT AS EXPRESSLY SET FORTH IN SUCH AGREEMENT FUJITSU LIMITED SUN MICROSYSTEMS INC AND THEIR AFFILIATES MAKE NO REPRESENTATIONS OR WARRANTI
43. support the RCI are referred to as an RCI host and an RCI VO unit Note respectively Furthermore RCI hosts and RCI VO units are generally referred to as RCI units Note RCI T O unit might be described as RCI IO unit While multiple RCI units consisting of an RCI host another RCI host and RCI I O units are connected through the RCI the RCI controls power supply to all these RCI units together and performs other controls on the RCI I O units By using RCI cables to connect RCI units and RCI setting commands the following RCI functions can be used Connecting and controlling RCI I O units Asynchronous RCI monitoring Note of RCI hosts in a cluster environment Note Asynchronous RCI monitoring is a function that immediately detects the panic state in any of the nodes that compose a cluster The asynchronous monitoring enables the cluster to quickly recover from a failure in a monitored node Note When the RCI network is used adequate consideration of security is necessary for LAN connections of domains C120 E360 06EN 1 1 CHAPTER 1 RCI Overview e RCI redundancy only for the high end system The eXtended System Control Facility XSCF unit Note ofthe high end system has a redundant configuration duplicated configuration realizing a high reliability system The redundant configuration of the XSCF unit can duplicate a network RCI network created by connecting RCI units with RCI cables Note The XSCF has a s
44. the RCI build procedure For information on using the RCI function refer to the SPARC Enterprise M3000 M4000 M5000 M8000 M9000 Servers RCI Build Procedure available on the website C120 E360 06EN Preface Abbreviated References to Other Documents Models In this manual the following abbreviated titles may be used when referring to a systems manual The following table lists the abbreviations used in this manual Abbreviated Title Full Title Overview Guide SPARC Enterprise M3000 Server Overview Guide SPARC Enterprise M4000 M5000 Servers Overview Guide SPARC Enterprise M8000 M9000 Servers Overview Guide Service Manual Installation Guide SPARC Enterprise M3000 Server Service Manual SPARC Enterprise M4000 M5000 Servers Service Manual SPARC Enterprise M8000 M9000 Servers Service Manual SPARC Enterprise M3000 Server Installation Guide SPARC Enterprise M4000 M5000 Servers Installation Guide SPARC Enterprise M8000 M9000 Servers Installation Guide Administration Guide SPARC Enterprise M3000 M4000 M5000 M8000 M9000 Servers Administration Guide XSCF User s Guide SPARC Enterprise M3000 M4000 M5000 M8000 M9000 Servers XSCF User s Guide XSCF Reference SPARC Enterprise M3000 M4000 M5000 M8000 M9000 Servers Manual XSCF Reference Manual Glossary SPARC Enterprise M3000 M4000 M5000 M8000 M9000 Servers Glossary The model names used in this manual are as follows
45. this command Refer to setprivileges 8 for more information OPTIONS The following options are supported c stat Displays the status of the RCI network c init Initializes the RCI setting c set host no Sets the address specified by host no for the RCI address An integer number ranging from 0 to 32 must be specified for host no The specification of one address cannot be duplicated among hosts connected to RCI In addition addresses must be assigned sequentially starting from 1 c set must be executed in the state where initialization has been completed by c init c initconfig Make the RCI setting at initial setting c initconfig must be executed when the RCI setting has been initialized by c init and the RCI address has been set by c set c addconfig Makes the RCI setting for when an RCI I O unit or host is added c replaceconfig Makes the RCI setting for when an RCI I O unit or host is replaced c ledon c ledoff Makes the CHECK LED of an RCI I O unit blink Stops the blinking CHECK LED of an RCI I O unit C120 E360 06EN 3 1 setrci c idpin Displays the RCI address of the RCI I O unit whose ID PIN has been pressed h Displays usage statement When used with other options or operands an error occurs s RCI network Specifies an RCI network Either of the networks shown below can be specified for RCI network The specificat
46. us s een eee eoo dots 3 5 EXIT STATUS ks et eres rrr Ee RD e den 3 7 9 2 SOCIO oet a K N eRe Re Sen a Re a 3 8 NAME 72 55 2322 55 ar e e canted ao e Pe tice d k 3 8 SYNOPSIS di ar Ade Pa e RR aa yanl eal a RR ERA AAA ARA 3 8 DESCRIPTION testet bottes enc M EE he 3 8 PRIVILEGES ass 24a ser een era aaa ya Sit Maid 3 8 OPTIONS in gd eM ye o ee cum ses sa d beares ee med eta 3 9 OPERANDS 3 0 ha e a Ad eh eke a WEE E ERA EA 3 9 C120 E360 06EN Contents EXTENDED DESCRIPTION 3 9 EXAMPLES 8888 be teme ue mpm 3 10 EXIT STATUS os s ya E AA da veh ts bee oe duc ee eve else eid 3 10 CHAPTER 4 Error Stalus mensae rue ow BER ea ne RR a La 4 1 41 setrcrerror statis ses eR ed b De hes UT AUN RR 4 1 42 setreic error status craro a gu pru RUE a 4 2 C120 E360 06EN xi Figure 1 1 Figure 1 2 Figure 1 3 Figure 1 4 C120 E360 06EN Contents Figures Connections to RCI I O units 1 4 Cluster connections 1 5 Duplicated configuration e ass ass Dhs dose SM KK KK KK BUE 1 5 Mixture of duplicated and unduplicated configurations 1 6 xiii 1 1 CHAPTER 1 RCI Overview This chapter gives an overview of the Remote Cabinet Interface RCI RCI Features The RCI is a device control interface used for connections of I O units to an RCI host In this manual a base cabinet and an I O unit that
47. with the customer s existing facilities power on each unit recognize alarms of each unit use the operator call function through a contact interface and perform other such operations Use the setrcic command at the setting of the facility control For details on the facility control contact authorized service personnel Power on wait The power on wait function automatically powers on RCI I O units before powering on RCI hosts To use this function in a domain execute the setpowerupdelay command in the domain For details see the XSCF Reference Manual Asynchronous RCI monitoring The following functions are available when the asynchronous RCI monitoring function is enabled for a cluster Mutual monitoring for detection of abnormalities in RCI hosts asynchronous monitoring In addition to performing periodic monitoring by INTERCONNECT this function detects abnormalities such as the panic state in an RCI host O Reliable stopping of an abnormal RCI host This function stops without fail an abnormal RCI host without terminating a hang up slowdown or generated panic Switch control This function controls line selector switching or other switching in the event that an RCI host fails C120 E360 06EN 1 3 CHAPTER 1 RCI Overview 1 3 RCI Connection Scheme This section outlines RCI connection patterns Basic configuration Figure 1 1 shows a connection pattern with an RCI host and RCI I O units Figure 1 1 Co
48. ystem control facility that runs on a service processor provided as standard in the base cabinet A board with a preinstalled XSCF control program XSCF firmware is an XSCF unit 1 2 RCI Functions This section describes the functions provided by the RCI RCI network status monitoring For stable operation of an RCI network an RCI host constantly monitors the status of the RCI network Upon detection of a failure in the RCI network the RCI host collects a hardware log and reports the failure to the relevant domain e Control of power supply to RCI I O units When an RCI host is powered on or off the RCI host powers on or off respectively RCI I O units synchronously When at least one RCI host in an RCI network is powered on all RCI I O units are powered on synchronously When all RCI hosts are powered off all RCI I O units are powered off synchronously Interlocking mechanism for power supply to domains When remote power control mode is set for a domain the domain is powered on and off in synchronization with other domains in the RCI network To set remote power control mode in a domain execute the setpwrmode command in the domain For details see the Enhanced Support Facility User s Guide for Machine Administration 1 2 C120 E360 06EN 1 2 RCI Functions Facility control Different kinds of facility control are available when the external power controller is connected to the RCI The external power controller can link

Download Pdf Manuals

image

Related Search

Related Contents

Adj 120-00004 storage enclosure  T-171取扱説明書  Goldstar DH3010B Dehumidifier User Manual  EarthMinded RS45-RC Installation Guide  MR 122B Coupe  Consulter le document en PDF - Bureau de la sécurité des  RALLYES CARTOGRAPHIQUES mode d`emploi…  User Guide - CNET Content Solutions  Mode d`emploi dossier de candidature PL    