Home

Fujitsu DX60S2 User's Manual

image

Contents

1. Server Server Server HBA HBA HBA HBA HBA HBA T T C Switch Switch Port Port Port Port CM 0 CM 1 e ETERNUS DX Disk storage system Figure 3 4 Multipath connection switch connection Caution el When configuring multipathing for reliability make sure to configure a redundant connection for the controllers of the ETERNUS DX Disk storage system Configure paths to connect to different controllers CM 0 and CM 1 Combinations of host interface port numbers Port 0 and Port 1 in controllers do not need to be taken into consideration Cluster configuration When a server is duplicated in a cluster configuration and the ETERNUS DX Disk storage sys tem is shared by multiple servers software to control the cluster configuration is required ETERNUS DX60 S2 Disk storage system User s Guide Site Planning Copyright 2012 FUJITSU LIMITED P3AM 5492 04ENZO Chapter 3 Connections 3 2 LAN Connection 3 2 LAN Connection The ETERNUS DX Disk storage system requires a LAN connection for operation management In addition information such as ETERNUS DX Disk storage system failures is notified to the remote support center Make sure to connect each controller to the LAN for operation Wi Note management i Administration SNMP Mail server NTP server terminal manager Remote support cente
2. Table 4 4 Priority order of 3 5 disk installation Priority order Type Disk capacity quantity RAID level 300GB 15krpm x 2 RAID1 2 300GB 15krpm x 6 RAID1 0 3 300GB 15krpm x 6 RAID5 4 300GB 15krpm x 6 RAID6 5 300GB 15krpm x 1 Hot spare 6 450GB 15krpm x 2 RAID1 7 450GB 15krpm x 6 RAID1 0 8 GC SAS 450GB 15krpm x 6 RAID5 9 450GB 15krpm x 6 RAID6 10 450GB 15krpm x 1 Hot spare 11 600GB 15krpm x 2 RAID1 12 600GB 15krpm x 6 RAID1 0 13 600GB 15krpm x 6 RAID5 14 600GB 15krpm x 6 RAID6 15 600GB 15krpm x 1 Hot spare 58 ETERNUS DX60 S2 Disk storage system User s Guide Site Planning Copyright 2012 FUJITSU LIMITED P3AM 5492 04ENZO Chapter 4 Rack and Optional Product Installation 4 3 Standard Installation Rules Before Shipment Only for Regions Other than EMEA amp I 4 3 3 Priority order Type Disk capacity quantity RAID level 16 1TB 7 2krpm x 2 RAID1 17 1TB 7 2krpm x 6 RAID1 0 18 1TB 7 2krpm x 6 RAID5 19 1TB 7 2krpm x 6 RAID6 20 1TB 7 2krpm x 1 Hot spare 21 2TB 7 2krpm x 2 RAID1 22 3 5 2TB 7 2krpm x 6 RAID1 0 23 Nearline 2TB 7 2krpm x 6 RAIDS 24 SAS disk 97B 7 2krpm x 6 RAID6 25 2TB 7 2krpm x 1 Hot spare 26 3TB 7 2krpm x 2 RAID1 27 3TB 7 2krpm x 6 RAID1 0 28 3TB 7 2krpm x 6 RAID5 29 3TB 7 2krpm x 6 RAID6 30 3TB 7 2krpm x 1 Hot spare Up
3. DI IN port This is not used Figure 1 22 Expander drive enclosure PS Drive interface ports A DI port is used to connect a controller enclosure The following table shows the DI port specifications Table 1 5 DI port specifications Interface E Connector type Number of ports for each expander speed max SAS 3Gbit s miniSAS SFF8088 1 IN 1 2 2 Power Supply Units The power supply unit transforms input AC power from a power socket to DC power and supplies power to each component Two power supply units are installed in each drive enclosure Each power supply unit contains fans Loin Figure 1 23 Power supply unit drive enclosure ETERNUS DX60 S2 Disk storage system User s Guide Site Planning Copyright 2012 FUJITSU LIMITED P3AM 5492 04ENZO Chapter 1 Hardware Configurations 1 3 Enclosure Connection Path 1 3 Enclosure Connection Path WW For a dual controller type a controller enclosure CE is connected to a drive enclosure DE with multiple paths A drive enclosure has two independent DI ports Path redundancy is maintained by connecting the drive enclosure to two controllers directly This configuration allows operation to continue even if one of the connection paths fails DI Drive Inte
4. cilia 9000 0000 0000 Ei S 0000 0000 ooo 0000 0000 0000 0000 o Figure 1 17 Front view of a drive enclosure without front cover 18 ETERNUS DX60 S2 Disk storage system User s Guide Site Planning Copyright 2012 FUJITSU LIMITED P3AM 5492 04ENZO Chapter 1 Hardware Configurations 1 2 Drive Enclosures Rear view e Single expander type This is not used DI IN port Cover _ Ee Expander EXP 0 Power supply unit Power supply unit PSU 0 PSU 1 Figure 1 18 Rear view of a drive enclosure single expander type e Dual expander type These are not used DI IN ports Expander EXP 0 Expander EXP 1 Power supply unit Power supply unit PSU 0 PSU 1 Figure 1 19 Rear view of a drive enclosure dual expander type Top view Figure 1 20 Top view of a drive enclosure 19 ETERNUS DX60 S2 Disk storage system User s Guide Site Planning Copyright 2012 FUJITSU LIMITED P3AM 5492 04ENZO Chapter 1 Hardware Configurations 1 2 Drive Enclosures Side view Figure 1 21 Side view of a drive enclosure 1 2 1 Expanders The expander is a component that controls the interaction between the controller and the disks
5. Host interface ports 0 Left 1 Right DI OUT port Figure 1 8 Rear view of a 3 5 type controller enclosure single controller type e Dual controller type LAN MNT port LAN RMT port LAN MNT port LAN RMT port PWC port PWC port Controller CM 0 Controller CM 1 Power supply unit Power supply unit PSU 1 PSU 0 Host interface ports Host interface ports 0 Left 1 Right 0 Left 1 Right DI OUT port DI OUT port Figure 1 9 Rear view of a 3 5 type controller enclosure dual controller type 14 ETERNUS DX60 S2 Disk storage system User s Guide Site Planning Copyright 2012 FUJITSU LIMITED P3AM 5492 04ENZO Chapter 1 Hardware Configurations 1 1 Controller Enclosure Top view Figure 1 10 Top view of a 3 5 type controller enclosure Side view Figure 1 11 Side view of a 3 5 type controller enclosure Controllers The controller contains a CPU cache memory System Capacitor Unit SCU non volatile mem ory host interface ports drive interface DI ports and LAN ports The controller controls all operations in the ETERNUS DX Disk storage system Cache memory Cache memory enables high speed processing by storing frequently used data The cache memory capacity for each controller is 1GB ETERNUS DX60 S2 Disk storage system User s Guide Site Planning Copyright 2012 FUJITSU LIMITED
6. c cececceceeeeeeeeeeeeceeeeeeaeeeeeeeeeeeeeeeees 31 2 5 2 Required Number of Outlets Sockets ccccccccceceeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeseceannecaeeeeeeeeeeeeeeeeeneee 34 2 6 KEES eege 36 2 6 1 Required Conditions cece cceceesesseeecceceecceeeeceeeececesesaeseeseeseeeeeececeseseeeeeeeeeesesaeaeaeasaaaaeasaessaeaeess 36 2 6 2 Breaking Characteristics e eekEEEEEKNEEK NENNEN fata cenecesasuceenh SERE A E 37 Chapter 3 COnnections ccccceeeeceeeeeeeeeeeeeeeee cena seeeeseeeeeeeneeeeeeaaeeeeeeesees Ai 3 1 Host gel ne 41 3 1 1 Host Interfaces 41 3 122 HOSt CONMECTION Pati EE 42 3 2 LAN Connection cicicicccsctoscscccscceccscsnceccsersisasascsesedavecersuetensvensecsunsennddencbsasdeceendeone 45 3 3 Power Supply een E 46 33 1 Input Power Supply LINES xg egetegtdegergeh ia ia de iaia a AEE aAa 46 33 2 UPS CONMEC ON sisirin sanidiini CAET A E AAA A A aE EEA ah 48 3 4 Power Synchronized Connections cccccccceeeeeee eect ee eeeeeeeeeeaeaaaeeeeeeeeeeeeeeeeeees 49 6 ETERNUS DX60 S2 Disk storage system User s Guide Site Planning Copyright 2012 FUJITSU LIMITED P3AM 5492 04ENZO Table of Contents Chapter A Rack and Optional Product Installation ccesseeeee 53 4 1 Rack Installation Requirements cesccccciccccnscdocteccsactaesaceciioscdedectneuiaaddcderdddeaianncede 53 4 2 Installable Racks issu SeetecacsecaceorastucnemedanienalesanadaaniuecuneqedasdaxatonGecedeueunaieeesacmneemeuaeser
7. 0 001 400 200 300 400 500 600 700 800 900 1000 126 150 PERCENT LOAD Figure 2 8 ETERNUS DX Disk storage system PSU breaking characteristics graph Table 2 12 ETERNUS DX Disk storage system PSU breaking characteristics Trip time sec Delay 100 125 150 200 400 600 800 1000 200E No Trip 45 to 15 to 6 to 0 7 to 0 008 to 0 006 to 0 004 to 500 250 90 15 5 0 4 0 08 ETERNUS DX Disk storage system gt gt b z amp cP CP S gt gt g j p Si a e E a i OO O a a a a a lt ZS S S fo 5 5 fa o Z Z o ri D Q el Go Vic CP Circuit Protector Figure 2 9 Example of a power supply connection without power distribution units D AA CAUTION Q e Only connect the ETERNUS DX Disk storage system to circuit protectors ETERNUS DX60 S2 Disk storage system User s Guide Site Planning Copyright 2012 FUJITSU LIMITED P3AM 5492 04ENZO Chapter 3 Connections 3 1 3 1 1 This chapter explains connections for the ETERNUS DX Disk storage system Host Connections FC iSCSI and SAS host interface models are available for the ETERNUS DX60 S2 The server and the ETERNUS DX Disk storage system can be connected directly or via a switch Host Interfaces This section describes each host interface FC Fibre Channel FC supports two connection topologies Fibre Ch
8. 240V Phase Single Frequency 50Hz 60Hz Input cable Connection type Straight through lt NEMA L6 30P Length 4m Quantity 2 Output cable Connection type IEC60320 C13 IEC60320 C14 Length 3m Quantity 16 ETERNUS DX60 S2 Disk storage system User s Guide Site Planning Copyright 2012 FUJITSU LIMITED P3AM 5492 04ENZO Chapter 2 ETERNUS DX Disk Storage System Installation This chapter explains the installation of the ETERNUS DX Disk storage system 2 1 2 1 1 Installation Specifications WW ETERNUS DX60 S2 The following table shows the specifications of the ETERNUS DX60 S2 Table 2 1 ETERNUS DX60 S2 installation specifications g ETERNUS DX60 S2 em 2 5 disk configuration 3 5 disk configuration Controller enclosure 483 x 650 x 88mm 483 x 650 x 88mm 2U 2U 483 x 650 x 88mm Dimensions Drive enclosure 2U WxDxH Power 1U 435 x 148 x 38mm distribution J unit 2U 485 x 280 x 43mm x 2 1 Controller enclosure 35kg Beete Drive enclosure 35kg weight 2 Power 1U 2kg distribution J unit 2U 6kg x 2 1 Service area Front 800mm Rear 800mm Voltage AC 100 120V AC 200 240V Phase Single Frequency 50Hz 60Hz Number of power supply units 2 for each enclosure Power For AC200V connections EMEARI region 1 amp 60320 C14G supplied as standard For AC200V connections Plug type Regions other than EMEA amp I NEMA L6 15
9. 300GB RAID1 0 C 2 5 SAS 450GB RAID1 D 2 5 SAS 600GB RAID6 H1 2 5 SAS 600GB hot spare Figure 4 4 Disk installation example at shipment 2 5 type controller enclosure P 3 5 type controller enclosure When a drive enclosure is added up to twenty four 3 5 disks can be installed When optional disks are purchased at the same time as the ETERNUS DX Disk storage system the ETERNUS DX Disk storage system is shipped from the factory with the disks installed in the enclosures The following diagram shows an example of the installation order for optional disks DE 1 Cc Cc Cc H2 H1 Cc Cc Cc CE 0 B B B B A A B B A A A A Optional disks A 3 5 SAS 450GB RAID1 0 B 3 5 SAS 600GB RAID1 0 H1 3 5 SAS 600GB hot spare C 3 5 Nearline SAS 2TB RAID5 H2 3 5 Nearline SAS 2TB hot spare Figure 4 5 Disk installation example at shipment 3 5 type controller enclosure ETERNUS DX60 S2 Disk storage system User s Guide Site Planning Copyright 2012 FUJITSU LIMITED P3AM 5492 04ENZO ETERNUS DX60 S2 Disk storage system User s Guide Site Planning P3AM 5492 04ENZO Date of issuance May 2012 Issuance responsibility FUJITSU LIMITED The content of this manual is subject to change without notice This manual was prepared with the utmost attention to detail However Fujitsu shall assume no responsibility for any operational pro
10. L Outlets OUTPUT Figure 1 27 Power distribution unit AC200 240V 2U Max 6 enclosures connection The following table shows the specifications of a power distribution unit and the AC cables that are provided Table 1 9 Power distribution unit AC200 240V 2U Max 6 enclosures connection and provided AC cable specifications Item Specifications Power Voltage AC200 240V Phase Single Frequency 50Hz 60Hz Input cable Connection type Straight through gt NEMA L6 20P Length 4m Quantity 2 Output cable Connection type IEC60320 C13 lt gt IEC60320 C14 Length 3m Quantity 12 PS Power distribution unit for DX60 S2 AC200 240V 2U Max 8 enclosures connection There are 16 outlets g Si Il A cl fo cl a el Be wwe L Outlets OUTPUT Figure 1 28 Power distribution unit AC200 240V 2U Max 8 enclosures connection ETERNUS DX60 S2 Disk storage system User s Guide Site Planning Copyright 2012 FUJITSU LIMITED P3AM 5492 04ENZO Chapter 1 Hardware Configurations 1 5 Power Distribution Units Only for Regions Other than EMEA amp I The following table shows the specifications of a power distribution unit and the AC cables that are provided Table 1 10 Power distribution unit AC200 240V 2U Max 8 enclosures connection and provided AC cable specifications Item Specifications Power Voltage AC200
11. 1 4 2 2 Installable Racks WW This section explains the racks in which the ETERNUS DX Disk storage system can be installed Fujitsu Racks The ETERNUS DX Disk storage system can be installed in a Fujitsu 19 inch rack For informa tion about whether the ETERNUS DX Disk storage system can be installed in an EOLed rack or not contact your sales representative Non Fujitsu Racks ETERNUS DX Disk storage systems are developed and their operation is guaranteed on the assumption that they are installed in Fujitsu 19 inch racks Since the ETERNUS DX Disk storage system cannot be tested for cooling and strength in non Fujitsu 19 inch racks the operations of ETERNUS DX Disk storage systems cannot be guaranteed Any problem that may occur by installing the ETERNUS DX Disk storage system in non Fujitsu racks is not covered by the war ranty If the ETERNUS DX Disk storage system needs to be installed in a non Fujitsu rack the follow ing conditions must be satisfied Rack specifications Use the rack mount kit supplied with the product to install the ETERNUS DX Disk storage system in the rack The rack specifications must satisfy the conditions listed below For rack specifica tions refer to the manual that is supplied with the rack that is used e Pitch for mounting holes EIA Standard Universal pitch e Size for mounting holes The size must be 9mm or more e Load bearing capacity The load bearing capacity must be equal to or lar
12. ETERNUS DX Disk storage system in a 19 inch rack Enclosures are installed in the following order from bottom to top The center of gravity must be taken into consideration to prevent a rack from toppling over Enclosures should generally be installed from bottom to top to lower the center of gravity and to ensure the safe use of racks Table 4 1 Enclosure installation order Order Enclosure Size height Power distribution unit PDU 1U 2U Controller enclosure CE 2U Drive enclosure DE 2U Caution D Install the controller enclosure and drive enclosure in the same rack e When determining the rack mounting layout consider the placement of Note each enclosure and the power distribution unit in the rack and the length of each cable For example if the ETERNUS DX Disk storage system is installed at the top of a 1800mm rack the surplus length of the power cord at the bottom of a rack should be about 2m If the storage system is installed at the bottom of a rack a space for the surplus of cables may not be available in some racks preventing the storage system from being pulled out when maintenance work is required In this case secure a space of 1U or more at the bottom when installing the storage system ETERNUS DX60 S2 Disk storage system User s Guide Site Planning Copyright 2012 FUJITSU LIMITED P3AM 5492 04ENZO Chapter 4 Rack and Optional Product Installation 4 2 Installable Racks 4 2 4 2
13. LIMITED P3AM 5492 04ENZO Chapter 3 Connections 3 3 Power Supply Connection 3 3 2 UPS Connection It is recommended that an Uninterruptible Power Supply System UPS be used as the power supply source for the ETERNUS DX Disk storage system to cope with power outages and momentary voltage drops in the normal power supply Note that when connecting an ETERNUS DX Disk storage system to a UPS with one power sup ply line the total value of the power requirements for all the enclosures must not exceed the UPS output capacity When one of the power supply lines fails for redundantly configured UPS units with two power supply lines all of the power for the ETERNUS DX Disk storage system must be supplied from the other line Select a UPS that can supply sufficient power so that the total value of the power requirements does not exceed the UPS output capacity in case only one power supply line is available For details about the necessary UPS output capacity refer to the specifications of the UPS that is used A UPS must satisfy the following conditions Rating capacity Secure a sufficient rating capacity for the total value of the maximum power requirements for the enclosures that are to be installed For the maximum power requirements of each enclosure refer to 2 1 Installation Specifications page 26 Supply time Consider the power supply time of the battery to make sure that the ETERNUS DX Disk storage system power is not t
14. system availability requirement considerations ETERNUS DX Power distribution unit Disk storage system G Za CHB rei C S C Sa f Se em L e a Figure 3 6 Dual line power supply when connecting to power sockets ETERNUS DX60 S2 Disk storage system User s Guide Site Planning Copyright 2012 FUJITSU LIMITED P3AM 5492 04ENZO Chapter 3 Connections 3 3 Power Supply Connection ETERNUS DX Power distribution unit Disk storage system ep GF C PSU Q UPS D e CI PSU Figure 3 7 Dual line power supply when connecting to UPS units ETERNUS DX Power distribution unit Disk storage system B CO r C PSU Figure 3 8 Single line power supply when connecting to power sockets facility Power supply ETERNUS DX Power distribution unit Disk storage system UPS eee rei D S 3 g C C PSU Figure 3 9 Single line power supply when connecting to a UPS unit ETERNUS DX Power distribution unit Disk storage system Sa C B B PSU D bz L amp G C C us C Psu Figure 3 10 Single line power supply when connecting to a power socket and a UPS unit 47 ETERNUS DX60 S2 Disk storage system User s Guide Site Planning Copyright 2012 FUJITSU
15. to twelve 3 5 disks can be installed in a controller enclosure 3 5 type or a drive enclosure Disks with different types can be installed in a single enclosure Install disks in the slots of a controller enclosure from Slot 0 to Slot 11 in ascending order according to the installation order in Table 4 4 Then install disks in the slots of a drive enclosure from Slot 0 to Slot 11 in ascending order Slot 9 Slot 10 Slot 11 Slot 5 Slot 6 Slot 1 Slot 2 Slot 7 Slot 3 Figure 4 3 Installation diagram for 3 5 disks Disk Installation Examples This section provides examples of disk installation at shipment 2 5 type controller enclosure Up to twenty four 2 5 disks can be installed in a controller enclosure When optional disks are purchased at the same time as the ETERNUS DX Disk storage system the ETERNUS DX Disk storage system is shipped from the factory with the disks installed in the enclosure The following diagram shows an example of the installation order for optional disks 59 ETERNUS DX60 S2 Disk storage system User s Guide Site Planning Copyright 2012 FUJITSU LIMITED P3AM 5492 04ENZO Chapter 4 Rack and Optional Product Installation 4 3 Standard Installation Rules Before Shipment Only for Regions Other than EMEA amp I CE 0 Optional disks A 2 5 SAS 300GB RAID1 B 2 5 SAS
16. unit for DX60 S2 AC200 240V 2U Max 6 enclosures Connechon cette eee ett eerie eerie eee AAEE teeter tees eee Enant EEE En ateen nanten 33 Specifications for power distribution unit for DX60 S2 AC200 240V 2U Max 8 enclosures Connechon eee ette eee teen ee eee t eee e eee teee sere naeeeeeetaeeeeeenaeeeenee 33 Required number of outlets and sockets to install power distribution units ee 34 Required conditions for distribution board circuit Drotechors 36 Power distribution unit 2U breaking characteristics Trip time eec H 37 Power distribution unit 1U breaking characteristics Trip time eec 1 39 ETERNUS DX Disk storage system PSU breaking characteristics Trip time sec 40 Ethernet frame capacity Jumbo Frame settngs 42 ETERNUS Web GUI operating environment cece eeeeenteeeeeeeeeaeeeeeeeetaeeeeseeenaeeeeeseeaees 45 Enclosure installation order 53 Specifications for the unit installation area ccc cc ccc ccceceeceeseaeseeeeeeeeseeseseseeeceeeeeseseeeeeeeeeeeees 55 Priority order of 2 5 disk installation ccccceeeeeeeeeeeeeeeeeeeeeeteeeeeeeeeseeeaeeeeeseneaeeeeeseeeaeeeeseenaees 57 Priority order of 3 5 disk installation 0 ccccceececeeeeeeeeeeeeeeeeeeeeeeeeeeeseneeaeeeeseneaaeeeeseeeeaeeeeeeaeees 58 ETERNUS DX60 S2 Disk storage system User s Guide Site Planning Copyright 2012 FUJITSU LIMITED P3AM 5492 04ENZO Chapter 1 Hardware Configurations This chapter explains hardware
17. 6ppb or less HF 3 6ppb or less Oil vapor 0 2mg m or less Seawater salt corrosion If the ETERNUS DX Disk storage system is installed on the ocean or premises within 0 5km from the coast necessary measures must be taken to prevent salt corrosion ee Operating 400gal Vibration limit i Not operating 1 000gal Noise Sound Pressure Level LpAm 43 5dB A 42 0dB A emission 3 Sound Power Level LWAd 6 0B 5 9B 1 A 2U power distribution unit is composed of two 1U power distribution units 2 These values are for when the controller enclosure has twenty four disks in a 2 5 disk configuration or when each enclosure has twelve disks in a 3 5 disk configuration 3 These values are measured when a single controller enclosure is configured in an environment in which the temperature is 23 2 C 27 ETERNUS DX60 S2 Disk storage system User s Guide Site Planning Copyright 2012 FUJITSU LIMITED P3AM 5492 04ENZO Chapter 2 ETERNUS DX Disk Storage System Installation 2 2 Package Size 2 2 Package Size The ETERNUS DX Disk storage system is shipped in cardboard boxes These boxes may not fit through some doorways or elevators To make sure that the ETERNUS DX Disk storage system can be moved to the installation site carefully check the transport route information Refer to 2 1 Installation Specifications page 26 for the maximum weight of each enclosure The following table shows t
18. 800mm or more Mitel elt Figure 2 1 Installation area and service area 29 ETERNUS DX60 S2 Disk storage system User s Guide Site Planning Copyright 2012 FUJITSU LIMITED P3AM 5492 04ENZO Chapter 2 ETERNUS DX Disk Storage System Installation 2 4 Installation Environment 2 4 2 4 1 2 4 2 Installation Environment WW E Sufficient consideration of the installation environment should be taken to ensure proper use of the ETERNUS DX Disk storage system Using the ETERNUS DX Disk storage system in an environment that does not satisfy the installation environment requirements may cause a failure to occur with the ETERNUS DX Disk storage system Air Conditioning It is important to consider the flows of cooling air intake air and exhaust air for the installation location The temperature in some ETERNUS DX Disk storage systems may rise when exhaust air is taken in from other ETERNUS DX Disk storage systems In addition check other factors that might affect the usage environment temperature such as the room size whether other ETERNUS DX Disk storage systems are installed and how many people are present in the room When installing air conditioning the ambient temperature should be considered Ambient temperature An ETERNUS DX Disk storage system is cooled by taking in air through the front intakes and pushing out the exhaust air through the rear of the ETERNUS DX Disk storage system If the intake air temperature doe
19. 9000 0099 9990 9099 9999 9900 9099 0099 9900 9000 0099 9000 9090 0099 9900 9099 0099 9000 9000 9090 9000 9000 0099 0000 0000 0099 a a a ayo yo 9900 0000 c000 9000 9090 0099 9990 9099 0000 9000 9090 9099 9900 9090 0099 9990 9099 0090 9900 9099 0999 9000 9000 0099 9990 9009 0099 9990 9099 9999 9000 9009 0009 a a a Gre Gallet 9000 0000 000 9000 9000 0099 9000 9000 9099 9990 9099 0000 x lt 9000 9090 0099 9000 9000 0099 V 0000 0000 0000 9900 9099 0099 D 9000 9000 9090 9900 9090 0099 z 9909 9099 0099 to a a 3 cc CA AED AS gogo 9000 a55 9990 9099 9999 9900 9009 9099 5090 9000 9999 9000 9099 9099 9900 9099 9999 9000 9000 9099 9000 9090 9099 9990 9099 9099 9000 9000 0099 9000 9000 0099 a A a yous Front view Figure 1 7 Front view of a 3 5 type controller enclosure without front cover 13 ETERNUS DX60 S2 Disk storage system User s Guide Site Planning P3AM 5492 04ENZO Copyright 2012 FUJITSU LIMITED Chapter 1 Hardware Configurations 1 1 Controller Enclosure Rear view e Single controller type LAN MNT port LAN RMT port PWC port Controller CM 0 Power supply unit Power supply unit PSU 1 PSU 0
20. Chapter 1 Hardware Configurations cccccccsssceeeeeeeeeeeeeeeeeeeeeeeeeeeees 11 1 1 Controller Enclosure cccccccceeeccceceeeeeceesececeueececeuececaueececsuaeececsecesecaneeeseans 11 1 1 1 Controllers 205 ed EE ege bed edd EEN edd edd ENNEN See TEE EE EE aE 15 1 1 2 Power Supply Units sisecidicccessascescevtadenacacssdendsanebwanbacdedsbadadcnes dead dadunsvannededs vaeed Eaa aad aaa aa 18 1 2 Dive Enclosures eegene 18 t21 EXPanders srren a a AA A E A EAA 20 T22 Power Supply RT CEET 20 1 3 Enclosure Connection Path eege geeeegeEEeeg eege tare iaie Fa iania 21 1 4 DISKS iee crud eas A esse even aan eaten eaten econ anata 22 IAI 25 DEKS TY RT Een Ve eae ota en aN A TT Fa Pee aS Ft ee 22 TT 22 1 5 Power Distribution Units Only for Regions Other than EMEA amp I 23 Chapter 2 ETERNUS DX Disk Storage System Installation 26 2 1 Installation Specifications svccccccccccccnssccecedessdccassavesaoctedsdectantacdeteddsersunsvasncasaeroesocs 26 2 1 1 ETERNUS DX60 Gi 26 2 2 Package E 28 2 3 Installation Area EE 29 2 4 Installation EMVINOMIMEGING EE 30 2 41 Ai Conditioning EE 30 2 4 2 Earthquake Resistance nrbis dannii a aa NA a aaa aiaa aa a A aAa 30 2 4 3 Load Bearing Capacity for FIOOTS scccccccesesecceceteeeeececenseneccecentensececensneseccenenseaeeedenseeeaecenseaes 31 2 5 Outlet Socket Specifications eet EEeeh 31 2 5 1 Specifications for Optional Power Supply Products
21. Copyright 2012 FUJITSU LIMITED P3AM 5492 04ENZO Chapter 2 ETERNUS DX Disk Storage System Installation 2 6 Circuit Protectors Table 2 11 Power distribution unit 1U breaking characteristics Trip time sec Delay 100 125 150 200 400 600 800 1000 200E No Trip 45 to 15 to 6 to 0 7 to 0 008 to 0 006 to 0 004 to 500 250 90 15 5 0 4 0 08 ETERNUS DX Disk storage system DE 01 CE PSU PSU PSU PSU YYYY CP CP Power distribution unit CP CP Distribution Distribution board board To power supply facility To power supply facility CP Circuit Protector Figure 2 7 Example of a power supply connection using a power distribution unit 1U 39 ETERNUS DX60 S2 Disk storage system User s Guide Site Planning Copyright 2012 FUJITSU LIMITED P3AM 5492 04ENZO Chapter 2 ETERNUS DX Disk Storage System Installation 2 6 Circuit Protectors PS For direct no power distribution unit connection The breaking characteristics of distribution board circuit protectors must be slower than the val ues shown in Figure 2 8 or equivalent to D IEC898 CURVE 200E 1000 100 10 sS DI TIME IN SECONDS 0 01
22. DI port specifications Table 1 2 DI port specifications Interface UE Connector type Number of ports for each controller speed max SAS 3Gbit s miniSAS SFF8088 1 P LAN ports Two LAN ports RJ 45 are installed in each controller Regions other than EMEA amp I Each LAN port is used for operation management MNT port and for remote support function RMT port respectively EMEA amp l region The MNT port is used for operation management and the RMT port is used for maintenance The following table shows the LAN port specifications Table 1 3 LAN port specifications Transfer Number of ports Interface Connector type speed max for each controller Ethernet 1000Base T 100Base TX 10Base T OPiS RJ45 2 E SCU A System Capacitor Unit SCU is installed in a controller as a backup power source in case of power outage The SCU is charged from an external power source while the ETERNUS DX Disk storage sys tem is running normally If a power failure is detected data in the cache memory is saved to the non volatile memory in the controller using the SCU There is no limit to the post failure data retention time E PWC ports A PWC port is installed in a controller The PWC port is used to connect a power synchronized unit to perform power synchronization The following table shows the PWC port specifications Table 1 4 PWC port specifications Number of ports for Interf
23. DX Disk storage system Figure 3 1 Single path connection direct connection Server Server Server HBA HBA HBA Switch Port Port Port Port CM 0 CM 1 ooa ETERNUS DX Disk storage system Figure 3 2 Single path connection switch connection PS Multipath configuration A multipath configuration connects the ETERNUS DX Disk storage system to a server via multi ple paths multipath System reliability is improved due to the path redundancy For multipath connections driver software to control multipathing is required If a path fails access can continue by using the path failover function that switches access from the failed path to another path The performance of the system can be improved by using the load balancing function to spread the access load over multiple paths To use the load balancing function four or more paths must be used to con 2 Note nect the server and the ETERNUS DX Disk storage system ETERNUS DX60 S2 Disk storage system User s Guide Site Planning Copyright 2012 FUJITSU LIMITED P3AM 5492 04ENZO Chapter 3 Connections 3 1 Host Connections Server Server HBA HBA HBA HBA Port Port Port Port CM 0 CM 1 l ETERNUS DX Disk storage system Figure 3 3 Multipath connection direct connection
24. P supplied as standard For AC100V AC200V connections IEC60320 C14 optional 26 ETERNUS DX60 S2 Disk storage system User s Guide Site Planning Copyright 2012 FUJITSU LIMITED P3AM 5492 04ENZO Chapter 2 ETERNUS DX Disk Storage System Installation 2 1 Installation Specifications ETERNUS DX60 S2 Item 2 5 disk configuration 3 5 disk configuration Maximum Controller AC 100 120V 510W 520VA 440W 450VA power enclosure AC 200 240V 500W 510VA 430W 440VA requirements Drive AC 100 120V 370W 380VA a enclosure AC 200 240V 370W 380VA Controller AC 100 120V 1 840kJ h 1 590kJ h Maximum heat enclosure AC 200 240V 1 800kJ h 1 550kJ h generation enclosure AC 200 240V 1 340kJ h Maximum Controller enclosure 2 9m min amount of exhaust air Drive enclosure 2 9m3 min Operating 10 40 C Temperature Not operating 0 50 C Shipping 40 60 C Temperature gradient 15 C Hr or less Operating 20 80 RH Humidity Not operating 8 80 RH Shipping 8 90 RH Humidity gradient 30 day or less Maximum wet bulb temperature 29 C Environmental Altitude above sea level 0 3 000m conditions Air borne dust 0 15mg m or less Gas concentration tolerance level Cl2 3 4ppb or less H2S 7 1ppb or less SO2 37ppb or less NH3 420ppb or less NO2 52ppb or less O3 5ppb or less HCI 6
25. P3AM 5492 04ENZO Chapter 1 Hardware Configurations 1 1 Controller Enclosure E Host interface ports Host interface ports are used to connect controllers to servers Two host interface ports can be installed in the controller of an ETERNUS DX Disk storage sys tem FC iSCSI and SAS are available as host interface FC model FC ports 0 Left 1 Right Figure 1 12 Host interface port FC model RES iSCSI ports 0 Left 1 Right FE iSCSI model be ben ch Eh ll we Figure 1 13 Host interface port iSCSI model SAS model SAS ports 0 Left 1 Right HOST T me Figure 1 14 Host interface port SAS model The following table shows the host interface port specifications Table 1 1 Host interface port specifications Interface Transfer speed max Connector type EN E FC A4Gbit s SFP 2 iSCSI 1Gbit s RJ 45 2 SAS 3Gbit s miniSAS SFF8088 2 ETERNUS DX60 S2 Disk storage system User s Guide Site Planning Copyright 2012 FUJITSU LIMITED P3AM 5492 04ENZO Chapter 1 Hardware Configurations 1 1 Controller Enclosure E Drive interface ports A DI port is used to connect a drive enclosure The following table shows the
26. P3AM 5492 04ENZO ETERNUS DX60 S2 Disk storage system User s Guide Site Planning co FUJITSU This page is intentionally left blank Preface Fujitsu would like to thank you for purchasing our ETERNUS DX60 S2 Disk storage system The ETERNUS DX60 S2 Disk storage system is designed to be connected to Fujitsu PRIMEQUEST or PRIMERGY or non Fujitsu servers This manual describes the environmental requirements that are necessary to install and use the ETERNUS DX60 S2 Disk storage system This manual is intended for use of ETERNUS DX60 S2 Disk storage system in regions other than Japan Please carefully review the information outlined in this manual Fourth Edition May 2012 Microsoft Windows Windows Server and Internet Explorer are either registered trademarks or trademarks of Microsoft Corporation in the United States and or other countries Mozilla Firefox and the Mozilla and Firefox logos are trademarks or registered trademarks of the Mozilla Foundation in the United States and other countries The company names product names and service names mentioned in this document are regis tered trademarks or trademarks of their respective companies 3 ETERNUS DX60 S2 Disk storage system User s Guide Site Planning Copyright 2012 FUJITSU LIMITED P3AM 5492 04ENZO About this Manual Organization This document is composed of the following four chapters Chapter 1 Hardware Configurations This chapter describes
27. X Disk Storage System Installation 2 5 Outlet Socket Specifications Power distribution unit 1U Up to two enclosures can be connected to a single power distribution unit 1U LC Output 4 outlets Input 2 sockets Figure 2 2 Power distribution unit 1U Power distribution unit 2U Power distribution unit for DX60 S2 AC200 240V 2U Max 6 enclosures connection Up to six enclosures can be connected Power distribution unit for DX60 S2 AC200 240V 2U Max 8 enclosures connection Up to eight enclosures can be connected Input 2 sockets O EI CH e EI ap DD ole 2 2 MADE IN JAPAN EI e ap p p p Ble 2 De e woe ra Lc 12 or 16 outlets Figure 2 3 Power distribution unit 2U OI0 ETERNUS DX60 S2 Disk storage system User s Guide Site Planning Copyright 2012 FUJITSU LIMITED P3AM 5492 04ENZO Chapter 2 ETERNUS DX Disk Storage System Installation 2 6 Circuit Protectors 2 6 2 6 1 Circuit Protectors WW Protection coordination must be secured between the distribution board circuit protectors and the ETERNUS DX Disk storage system or power distribution units to protect the ETERNUS DX Disk storage system by blocking the failed circuit immediately when a power supply input error occurs Distribution board circuit protectors must satisfy the following required conditions and breaking characteristics Required Condit
28. ace Connector type each controller RS232C D sub9 pin 1 ETERNUS DX60 S2 Disk storage system User s Guide Site Planning Copyright 2012 FUJITSU LIMITED P3AM 5492 04ENZO Chapter 1 Hardware Configurations 1 2 Drive Enclosures 1 1 2 1 2 Power Supply Units The power supply unit transforms input AC power from a power socket to DC power and supplies power to each component Two power supply units are installed in each controller enclosure Each power supply unit contains fans Tin Figure 1 15 Power supply unit controller enclosure Drive Enclosures This section explains the main components in the drive enclosure The drive enclosure contains disks installed in the front and expanders and power supply units in the rear Up to 12 disks can be installed in a 3 5 type drive enclosure Since the power supply units are redundant operations can continue even if one of them fails Drive enclosure Front view e With front cover O 080 08080 eer E OC E O o e O Figure 1 16 Front view of a drive enclosure with front cover e Without front cover 3 5 disk lo0000000000 00000000000 00000000000 199000000000 1090000000 0000000000 loood000u000 00000000 gel 29900006000 00000000000 0000000000 0000000 000000000 looo000 109001
29. annel Arbitrated Loop FC AL and Fabric Direct connections and switch connections to servers are available The maximum transfer speed is 4Gbit s When FC switches are used zoning should be set for the FC switches to Caution ensure the security of data iSCSI Direct connections and switch connections to servers are available The maximum transfer speed is 1Gbit s In order to maintain iSCSI performance the iSCSI network should be physically separated from other types of networks such as networks for Internet access and file transfers e CHAP CHAP authentication can prevent unauthorized access The following CHAP authentication methods are supported Unidirectional CHAP Bidirectional CHAP e Jumbo Frame Enabling Jumbo Frame makes data transfer more efficient by increasing the amount of data that can be transferred for each Frame ETERNUS DX60 S2 Disk storage system User s Guide Site Planning Copyright 2012 FUJITSU LIMITED P3AM 5492 04ENZO Chapter 3 Connections 3 1 Host Connections Table 3 1 Ethernet frame capacity Jumbo Frame settings Jumbo Frame settings Ethernet frame capacity Enabled Up to 9000 bytes Disabled Up to 1500 bytes Caution O e Confirm that the connected device supports Jumbo Frame before enabling Jumbo Frame e Server side CPU load can be reduced by using Jumbo Frame However UO performance may be reduced by 10 to 30 e When using a LAN switch that suppor
30. apacity quantity RAID level 1 300GB 10krpm x 2 RAID1 2 300GB 10krpm x 6 RAID1 0 3 300GB 10krpm x 6 RAID5 4 300GB 10krpm x 6 RAID6 5 300GB 10krpm x 1 Hot spare 6 450GB 10krpm x 2 RAID1 7 450GB 10krpm x 6 RAID1 0 8 450GB 10krpm x 6 RAID5 9 450GB 10krpm x 6 RAID6 10 2 5 SAS 450GB 10krpm x 1 Hot spare 11 disk 600GB 10krpm x 2 RAID1 12 600GB 10krpm x 6 RAID1 0 13 600GB 10krpm x 6 RAID5 14 600GB 10krpm x 6 RAID6 15 600GB 10krpm x 1 Hot spare 16 900GB 10krpm x 2 RAID1 17 900GB 10krpm x 6 RAID1 0 18 900GB 10krpm x 6 RAID5 19 900GB 10krpm x 6 RAID6 20 900GB 10krpm x 1 Hot spare 21 1TB 7 2krpm x 2 RAID1 22 25 1TB 7 2krpm x 6 RAID1 0 23 Nearline 1TB 7 2krpm x 6 RAID5 24 SAS disk 47 B 7 2krpm x 6 RAID6 25 1TB 7 2krpm x 1 Hot spare Up to twenty four 2 5 disks can be installed in a 2 5 type controller enclosure Install disks in the slots of a controller enclosure from Slot 0 to Slot 23 in ascending order according to the installation order in Table 4 3 57 ETERNUS DX60 S2 Disk storage system User s Guide Site Planning Copyright 2012 FUJITSU LIMITED P3AM 5492 04ENZ0 Chapter 4 Rack and Optional Product Installation 4 3 Standard Installation Rules Before Shipment Only for Regions Other than EMEA amp I Figure 4 2 P 3 5 disks Installation diagram for 2 5 disks The following table shows the priority order of 3 5 disk installation
31. blems as the result of errors omissions or the use of information in this manual Fujitsu assumes no liability for damages to third party copyrights or other rights arising from the use of any information in this manual The content of this manual may not be reproduced or distributed in part or in its entirety without prior permission from Fujitsu Be FUJITSU
32. configurations for the ETERNUS DX Disk storage system 1 1 Controller Enclosure WW This section explains the main components in the controller enclosure The controller enclosure contains disks installed in the front and controllers and power supply units in the rear Since the power supply units are redundant operations can continue even if one of them fails There are two models a single controller type and a dual controller type For a dual controller type operations can continue even if one of the controllers fails IMPORTANT e The single controller type differs from the dual controller type by the fol lowing features The controller and expander are not duplicated Hot maintenance or swapping of the controller and expander is not possible Concurrent firmware loading or update of the controller firmware and expander firmware is not possible Multipath connection to a single server is not available e Fujitsu recommends that the dual controller types in which the controller and expander are duplicated be used in a system where a high level of reliability is required P External views of a 2 5 type controller enclosure Front view 2 5 disk fal fa fam Figure 1 1 Front view of a 2 5 type controller enclosure ETERNUS DX60 S2 Disk storage system User s Guide Site Planning Copyright 2012 FUJITSU LIMITED P3AM 5492 04ENZO Chapter 1 Ha
33. connecting three or more servers Powering on sequence 1 Power on of all the server UPS units 2 Server startup The server OS startup is suspended until the ETERNUS DX Disk storage system startup is complete 1 3 Issuance of command to turn on the ETERNUS DX Disk storage system from the power synchronized unit 4 ETERNUS DX Disk storage system startup 4 The server must be set to suspend server OS startup until the ETERNUS DX Disk storage system startup is complete ETERNUS DX60 S2 Disk storage system User s Guide Site Planning Copyright 2012 FUJITSU LIMITED P3AM 5492 04ENZO Chapter 3 Connections 3 4 Power Synchronized Connections Powering off sequence 1 Shutdown of all the servers 2 Shutdown of all the server UPS units 3 Issuance of command to turn off the ETERNUS DX Disk storage system from the power synchronized unit 4 ETERNUS DX Disk storage system shutdown Refer to the manual that is provided with a power synchronized unit for details about connection configurations with power synchronized units and required settings ETERNUS DX60 S2 Disk storage system User s Guide Site Planning Copyright 2012 FUJITSU LIMITED P3AM 5492 04ENZO Chapter A Rack and Optional Product Installation 4 1 This chapter explains the requirements for installation of racks and the optional products for an ETERNUS DX Disk storage system Rack Installation Requirements This section explains the requirements for installing the
34. d unit detects the AC power output of the target devices for power syn chronization and commands the ETERNUS DX Disk storage system to synchronize the power with the target devices When the power synchronized unit detects the AC power output of any server UPS unit the power synchronized unit commands the ETERNUS DX Disk storage system to turn on When the power synchronized unit does not detect AC power output in any of the server UPS units the power synchronized unit commands the ETERNUS DX Disk storage system to turn off The server UPS unit must have a function in the management software that controls the AC power output according to when the server powers on and off The server UPS unit must have one unused outlet to connect to the power synchronized unit ETERNUS DX60 S2 Disk storage system User s Guide Site Planning Copyright 2012 FUJITSU LIMITED P3AM 5492 04ENZO Chapter 3 Connections 3 4 Power Synchronized Connections e When connecting one or two servers UPS setting Server C Kee UPS management software UPS q Power synchronized unit PWC 7 ETERNUS DX z RS232C cable Disk storage system An instruction is issued to turn on off the ETERNUS DX Disk storage system when AC output no AC output is detected unnnannannannnnnn nn Figure 3 11 Power control using a power synchronized unit when connecting one or two servers Powering on sequ
35. eeeeeeeeeesesenaeeaeeees 22 Power distribution unit AC200 240V 1U Max 2 enclosures connection and provided AC cable specifications cc ceeeeceeceeeeeeeeeeeeeeeeeeeaecaecaeeeeeeeeeeesesecceccnaesaeeeeeeeeeeetes 23 Power distribution unit AC200 240V 2U Max 6 enclosures connection and provided AC cable specifications cccceceeceeceeeeeeeeeeeeeeeeeceaeaaecaeeeeeeeeeeeseseececcnaecaeeeeeeeeeeneees 24 Power distribution unit AC200 240V 2U Max 8 enclosures connection and provided AC cable specifications ccccesceceeceeeeeeeeeeeeeeeeceaecaecaeeeeeeeeeeeeeseceaccneesaeeeeeeeeeeeeees 25 ETERNUS DX60 S2 installation specifications 2 0 00 ceceececeeceeceee cee eeeeeeeeeeeesecncnaecaeeeeeeeeees 26 Package size for regions other than EMEASI nnn 28 Specifications for power cords supplied with the ETERNUS DX Disk storage system for the EMEA amp I region ccceeeseceeeeeeeeeeeeeeeeeeneseeaaenneseeaaaeeeeeedaaeseeseeeaeeeeseeeeenseseeeeenneess 32 Specifications for power cords supplied with the ETERNUS DX Disk storage system for regions other than EMEA amp I ececceeeeeeeeeeeeseeeeee eee eeeeeeeeeseceeeeeeeseneeeeeeseeeeaeeeeseeaaeeeseneaaees 32 Specifications for power distribution unit for DX60 S2 AC200 240V 1U Max 2 enclosures Conpnechon ce ceeteeete eee ete eee eee ttnt eee e eee teeta nese ee taeee eee taaeeeeeesaeeeene 33 Specifications for power distribution
36. ence 1 2 4 Wb Power on of all the server UPS units Server startup The server OS startup is suspended until the ETERNUS DX Disk storage system startup is complete 1 Issuance of command to turn on the ETERNUS DX Disk storage system from the power synchronized unit ETERNUS DX Disk storage system startup The server must be set to suspend server OS startup until the ETERNUS DX Disk storage system startup is complete Powering off sequence 1 2 Shutdown of all the servers Shutdown of all the server UPS units Issuance of command to turn off the ETERNUS DX Disk storage system from the power synchronized unit ETERNUS DX Disk storage system shutdown 50 ETERNUS DX60 S2 Disk storage system User s Guide Site Planning Copyright 2012 FUJITSU LIMITED P3AM 5492 04ENZO Chapter 3 Connections 3 4 Power Synchronized Connections e When connecting three or more servers q sever UPS unit for Server 1 e Server 3 en e UPS unit for z AC sensor ER CS unit 1 D C P Server 0 UPS unit for R FH Server 0 R Server 2 km q UPS unit for AC sensor CF SENET S unit 0 D Power synchronized 7 PWC PWC ETERNUS DX Disk storage system srrennsreesc gt ETERNUS DX Disk storage system PWC Figure 3 12 Power control using a power synchronized unit when
37. es Figure 3 12 Power control using a power synchronized unit when connecting three or more servers 51 Figure 4 1 Unit installation area eecceeeeee eee eencee eee eeeneeeeeeeeeeeeeeeseeeeeeeeesaaeeeeeceeeeeeeeseeeaeeeesenaeeeeseenaneees 55 Figure 4 2 Installation diagram for 2 5 deks nannten 58 Figure 4 3 Installation diagram for 3 5 deks naene 59 Figure 4 4 Disk installation example at shipment 2 5 type controller encosure 60 Figure 4 5 Disk installation example at shipment 3 5 type controller encosure 60 ETERNUS DX60 S2 Disk storage system User s Guide Site Planning Copyright 2012 FUJITSU LIMITED P3AM 5492 04ENZO Table 1 1 Table 1 2 Table 1 3 Table 1 4 Table 1 5 Table 1 6 Table 1 7 Table 1 8 Table 1 9 Table 1 10 Table 2 1 Table 2 2 Table 2 3 Table 2 4 Table 2 5 Table 2 6 Table 2 7 Table 2 8 Table 2 9 Table 2 10 Table 2 11 Table 2 12 Table 3 1 Table 3 2 Table 4 1 Table 4 2 Table 4 3 Table 4 4 List of Tables Host interface port SpeCificatioNS ccc cccecee eee ceeecee cae ce eee eee eect cece eceacaecaeeeeeeeeeeesetteeseeseaneeeaeeees 16 RB Ge ee 17 LAN port specifications ccc ceceeeceeceeeeteccece eee eeeee teeta eaaeaecaeeeeeeeeeeeseseecaaaaaeaaeceeeeeeeeestsessenieeaeeees 17 PWC port specification S ET 17 DI port specifications eee 20 el E ee 22 3 5 disk specifications 2 0 cee cece ee eeeeeeeee cee ee eee eee ee tesa caaeaaecaeeeeeeeeeeeeedsccaaaaaeaee
38. ets Sockets The number of power outlets sockets required to install the ETERNUS DX Disk storage system depends on the number of drive enclosures and power distribution units It is recommended that the power cord of a drive enclosure is connected to the power distribution unit that is installed in the same rack Secure the necessary number of power outlets within the same rack to avoid connecting power cords to power outlets in different racks It may be neces sary to purchase additional power distribution units depending on the installation locations of enclosures Without power distribution units Two power sockets are required for each enclosure controller enclosure and drive enclosure With power distribution units Two power sockets are required for each power distribution unit There are three types of power distribution units The size and number of outlets are different for each type Table 2 8 Required number of outlets and sockets to install power distribution units Product name Number of outlets Number of sockets Power distribution unit for DX60 S2 AC200 240V 1U 4 2 Max 2 enclosures connection Power distribution unit for DX60 S2 AC200 240V 2U 12 2 Max 6 enclosures connection Power distribution unit for DX60 S2 AC200 240V 2U 16 2 Max 8 enclosures connection ETERNUS DX60 S2 Disk storage system User s Guide Site Planning Copyright 2012 FUJITSU LIMITED P3AM 5492 04ENZO Chapter 2 ETERNUS D
39. ger than the total weight of the ETERNUS DX Disk storage system e Unit installation area The dimensions of the area shown in Figure 4 1 must match the conditions described in Table 4 2 ETERNUS DX60 S2 Disk storage system User s Guide Site Planning Copyright 2012 FUJITSU LIMITED P3AM 5492 04ENZO Chapter 4 Rack and Optional Product Installation 4 2 Installable Racks Rack front door Figure 4 1 Table 4 2 ETERNUS DX Disk storage system Rack pillars Unit installation area Specifications for the unit installation area Rack rails Rack rear door Specification Condition 1 Rack front space From the fixed part of the ETERNUS DX Disk storage system on the front side to the inner side of the front rack door 40mm or more 2 Mount bracket length Size between each end of the front and rear rack pillars 630mm to 800mm 3 Rack space From the fixed part of the ETERNUS DX Disk storage system on the front side to the inner side of the rear rack door 830mm or more 4 Rack mount kit installation area 482mm or more recommended P Placement conditions When determining service areas refer to the installation document of the rack to be used Install air conditioning in order to ensure that the interior temperature of the rack satisfies the temperature conditions listed in 2 1 Installation Specifications page 26 and 2 4 1 Air Conditioning
40. he package size and the maximum package weight of each compo nent for regions other than EMEA amp I Table 2 2 Package size for regions other than EMEA amp I Package size K Component WxDxH Maximum weight 2 5 type 610 x 840 x 250mm 40kg Controller enclosure 3 5 type 610 x 840 x 250mm 40kg Drive enclosure 3 5 type 610 x 840 x 250mm 40kg i 2 5 196 x 236 x 124mm 0 6kg Disk 1 3 5 225 x 305 x 135mm 1 1kg EE 1U 570 x 710 x 160mm 4kg Power distribution unit 2U 390 x 590 x 180mm x 2 7kg x 2 When an order for optional disks to be installed in the factory is placed enclosures are shipped with the disks preinstalled When optional disks are ordered without preinstallation each disk is shipped in an individual package ETERNUS DX60 S2 Disk storage system User s Guide Site Planning Copyright 2012 FUJITSU LIMITED P3AM 5492 04ENZO Chapter 2 ETERNUS DX Disk Storage System Installation 2 3 Installation Area 2 3 Installation Area This section explains the installation area and the service area that are required for an ETERNUS DX Disk storage system that is installed in a Fujitsu 19 inch rack Secure service areas that are 800mm or more in the front and rear of the ETERNUS DX Disk storage system The size of the side areas varies depending on the rack specifications i 1 Rear service area 800mm or more i ETERNUS DX Disk storage system Front service area
41. ions The distribution board circuit protectors must satisfy the required conditions that are listed in Table 2 9 Table 2 9 Required conditions for distribution board circuit protectors Current capacity Power supply Connected device voltage Regions other EMEA amp I than EMEA amp I region Power distribution unit for DX60 S2 AC200 240V 1U Max 2 enclosures connection EEN 15A _ Power distribution unit for DX60 S2 AC200 240V 2U Max 6 enclosures connection AC200 240V 20A gt Power distribution unit for DX60 S2 AC200 240V 2U Max 8 enclosures connection GES 30A ETERNUS DX Disk storage system AC100 120V 15A 16A without power distribution units AC200 240V ETERNUS DX60 S2 Disk storage system User s Guide Site Planning Copyright 2012 FUJITSU LIMITED P3AM 5492 04ENZO Chapter 2 ETERNUS DX Disk Storage System Installation 2 6 Circuit Protectors 2 6 2 Breaking Characteristics For power distribution unit 2U connection The breaking characteristics 1 of distribution board circuit protectors must be slower than the values shown in Figure 2 4 or equivalent to D IEC898 1 Relationship between the size of excess current and operation time 10000 MAY TRIP 1000 Q TIME IN SECONDS 001 0 100150200 300 400 PERCENT OF RATED CURRENT 125 500 600 DELAY 63 700 800 900 1000 Figure 2 4 Power distribution unit 2U breaking characteristics g
42. istics orapb 38 Example of a power supply connection using a power distribution unit OU 39 ETERNUS DX Disk storage system PSU breaking characteristics orapb 40 Example of a power supply connection without power distribution Units ssesssssssssesrereeeee 40 Single path connection direct conpechon cece eeeeeee eee eeeeeeeeeteeeeeeeeeseneaeeeeteeenaaeeeeeeenees 43 Single path connection Switch CONNECTION 0 0 eee eee eeeeeee eee eeeeeee eee teeeeeeeeeseeeeeeeeseeeaeeeeeeeenees 43 Multipath connection direct CONNECTION eect tenet eee ettee eter eteee eee taeeeeeeetaeeeeeeetneeeenee 44 Multipath connection Switch Connechon cece eeeeeeee eee eeeeeeeeeeeeeeeeeeeeeseeeaeeeeeeeeeaeeeeseeenaees 44 Example of a LAN connecti EE 45 Dual line power supply when connecting to power sockets ssssssessssssseseerenrrnnrenrnnreerernennn 46 Dual line power supply when connecting to UPS Units cccecceceeeeeeeeeeeeeeeeneecaeceeeeeeeeteettees 47 Single line power supply when connecting to power sockeis 47 Single line power supply when connecting to a UPS unit oo eee rece eeneeeeeeeeetaeeeeeeenaaes 47 Single line power supply when connecting to a power socket and a UPS unt 47 Power control using a power synchronized unit when connecting one or two servers 50 ETERNUS DX60 S2 Disk storage system User s Guide Site Planning Copyright 2012 FUJITSU LIMITED P3AM 5492 04ENZO List of Figur
43. ive enclosure single expander type ceeeceeeeeeeeee eee eeeeeee eee teteeeeeeettaeeeeree 19 Rear view of a drive enclosure dual expander pe 19 Top view Of a drive CNClOSUNE eegen e ale caheeviack d en 19 Side view of a drive encosure eee eeeeeeeceeceeenne eee eeeeeae eee eeeeaaeeeeeeeeaaaeeeeeeeaaaeeeseeeaaeeeeseenaeeeeeeeeaas 20 Expander drive encdosure 2 ccceceeeeeeeeen ee eeeececteeeeeeedaneeeesenaaneneeseadeneceedeeaaneceeeeenenenedeesneeees 20 Power supply unit drive enclosure 0 0 22 ee ceeeeeee centre eee eeeee cette tae eee eee teeeeeetaaeeeeeesiaeeeeeesnaeeeeeee 20 Enclosure connection path dual controller Type 21 Enclosure connection path single controller tye c cceeeeeeeeeeeeeeeeeceeeeeeeeeeeeeeeeeaeeeeeeeeatees 21 Power distribution unit AC200 240V 1U Max 2 enclosures Connection cceeeeeeereeeeees 23 Power distribution unit AC200 240V 2U Max 6 enclosures Connection cceeeeeeeeeeeeees 24 Power distribution unit AC200 240V 2U Max 8 enclosures Connection cceeeeeeeeeeeees 24 Installation area ANd service area cece eeeeeee cere ee eee tees Annn Eunana EEE Anat eee naeeeerenieeeeeetea 29 Power distribution unit 1U occse A 35 Power distribution unit OU 35 Power distribution unit 2U breaking characteristics orapb 37 Example of a power supply connection using a power distribution unit OU 38 Power distribution unit 1U breaking character
44. lation 2 5 Outlet Socket Specifications PS Power distribution units only for regions other than EMEA amp I Power distribution unit for DX60 S2 AC200 240V 1U Max 2 enclosures connection Table 2 5 Specifications for power distribution unit for DX60 S2 AC200 240V 1U Max 2 enclosures connection Output Input Remarks Outlet type Plug type Socket type Cable length IEC60320 C13 NEMA L6 15P NEMA L6 15R 4 0m 250V 15A Normal usage lt 12A Power distribution unit for DX60 S2 AC200 240V 2U Max 6 enclosures connection Table 2 6 Specifications for power distribution unit for DX60 S2 AC200 240V 2U Max 6 enclosures connection Output Input Remarks Outlet type Plug type Socket type Cable length IEC60320 C13 NEMA L6 20P NEMA L6 20R 4 0m 250V 20A Normal usage lt 16A Power distribution unit for DX60 S2 AC200 240V 2U Max 8 enclosures connection Table 2 7 Specifications for power distribution unit for DX60 S2 AC200 240V 2U Max 8 enclosures connection Output Input Remarks Outlet type Plug type Socket type Cable length IEC60320 C13 NEMA L6 30P NEMA L6 30R 4 0m 250V 30A Normal usage lt 24A 33 ETERNUS DX60 S2 Disk storage system User s Guide Site Planning Copyright 2012 FUJITSU LIMITED P3AM 5492 04ENZO Chapter 2 ETERNUS DX Disk Storage System Installation 2 5 Outlet Socket Specifications 2 5 2 Required Number of Outl
45. ng capacity of the floor gt ETERNUS DX Disk storage system weight Installation area that includes service areas If the condition above is not satisfied additional measures are required to ensure sufficient load bearing capacity Contact your installation contractor for details about the necessary measures that must be taken Outlet Socket Specifications WW Power can be supplied to the ETERNUS DX Disk storage system from two power sources because each enclosure has two power supply units During normal operation each of the power sources supplies half of the necessary power When one of the power supply lines fails all of the necessary power is supplied from only one power source Using the same power supply condition for all of the power supply units is recommended so that different power supply conditions such as whether power distribution units are used or not and input voltage are not used for the ETERNUS DX Disk storage system This section explains the power connection specifications of the ETERNUS DX Disk storage sys tems Specifications for Optional Power Supply Products This section explains the specifications of optional power cords and power related optional prod ucts When using power distribution units the number of outlets that are required for controller enclo sure and drive enclosure connection should be taken into consideration In addition make sure that the plug type of the power distribution u
46. nit fits the power socket when using an existing power socket If the plug type does not fit the power socket replace the socket ETERNUS DX60 S2 Disk storage system User s Guide Site Planning Copyright 2012 FUJITSU LIMITED P3AM 5492 04ENZO Chapter 2 ETERNUS DX Disk Storage System Installation 2 5 Outlet Socket Specifications P Power cords Power cords supplied with the ETERNUS DX Disk storage system for the EMEA amp I region Table 2 3 Specifications for power cords supplied with the ETERNUS DX Disk storage system for the EMEA amp I region Usage Plug type Socket type Cable length Remarks Used for connection between the ETERNUS DX Disk storage system and the socket IEC60320 C13 e IEC60320 C14G IEC60320 C14G IEC60320 C13 2 5m 250V 10A Power cords supplied with the ETERNUS DX Disk storage system for regions other than EMEA amp I Table 2 4 Specifications for power cords supplied with the ETERNUS DX Disk storage system for regions other than EMEA amp l Usage Plug type Socket type Cable length Remarks Used for connection NEMA L6 15P NEMA L6 15R_ 4 0m 250V 15A between the ETERNUS Normal usage DX Disk storage system lt 12A and the socket IEC60320 C13 e NEMA L6 15P 32 ETERNUS DX60 S2 Disk storage system User s Guide Site Planning Copyright 2012 FUJITSU LIMITED P3AM 5492 04ENZO Chapter 2 ETERNUS DX Disk Storage System Instal
47. ns Warning signs are shown throughout this manual in order to prevent injury to the user and or material damage These signs are composed of a symbol and a message describing the recom mended level of caution The following explains the symbol its level of caution and its meaning as used in this manual This symbol indicates the possibility of minor or moderate personal A CAUTION injury as well as damage to the ETERNUS DX Disk storage system and or to other users and their property if the ETERNUS DX Disk storage system is not used properly How Warnings are Presented in this Manual A message is written beside the symbol indicating the caution level This message is marked with a vertical ribbon in the left margin to distinguish this warning from ordinary descriptions An example is shown here Warning Level Indicator Example Warning Warning Type Indicator Warning Details To avoid damaging the ETERNUS DX Disk storage system pay attention to the following points when cleaning the ETERNUS DX Disk storage system Make sure to disconnect the power when cleaning Be careful that no liquid seeps into the ETERNUS DX Disk storage system when using cleaners etc Do not use alcohol or other solvents to clean the ETERNUS DX Disk storage system Warning Layout Ribbon 5 ETERNUS DX60 S2 Disk storage system User s Guide Site Planning Copyright 2012 FUJITSU LIMITED P3AM 5492 04ENZO Table of Contents
48. ower Distribution Units Only for Regions Other than EMEA amp I WW Samm There are two sizes for power distribution units 1U and 2U A power distribution unit is an option to connect power supply units to power outlets when power sockets are limited Power distribution unit for DX60 S2 AC200 240V 1U Max 2 enclosures connection There are four outlets and two inlets Outlets OUTPUT Inlets INPUT Figure 1 26 Power distribution unit AC200 240V 1U Max 2 enclosures connection The following table shows the specifications of a power distribution unit and the AC cables that are provided Table 1 8 Power distribution unit AC200 240V 1U Max 2 enclosures connection and provided AC cable specifications Item Specifications Power Voltage AC200 240V Phase Single Frequency 50Hz 60Hz Input cable Connection type IEC60320 C13 gt NEMA L6 15P Length 4m Quantity 2 Output cable Connection type IEC60320 C13 lt gt IEC60320 C14 Length 3m Quantity 4 ETERNUS DX60 S2 Disk storage system User s Guide Site Planning Copyright 2012 FUJITSU LIMITED P3AM 5492 04ENZO Chapter 1 Hardware Configurations 1 5 Power Distribution Units Only for Regions Other than EMEA amp I PS Power distribution unit for DX60 S2 AC200 240V 2U Max 6 enclosures connection There are 12 outlets
49. page 30 55 ETERNUS DX60 S2 Disk storage system User s Guide Site Planning Copyright 2012 FUJITSU LIMITED P3AM 5492 04ENZ0 Chapter 4 Rack and Optional Product Installation 4 3 Standard Installation Rules Before Shipment Only for Regions Other than EMEA amp I 4 3 Standard Installation Rules Before Shipment Only for Regions Other than EMEA amp l WW E G This section explains the rules for combining the following optional products and standard installation rules that apply before shipment from the factory e Drive enclosures e Disks 4 3 1 Drive Enclosures This section explains the installation rules for a drive enclosure M 2 5 type controller enclosure Drive enclosures cannot be connected P 3 5 type controller enclosure Only one drive enclosure can be connected ETERNUS DX60 S2 Disk storage system User s Guide Site Planning Copyright 2012 FUJITSU LIMITED P3AM 5492 04ENZO Chapter 4 Rack and Optional Product Installation 4 3 Standard Installation Rules Before Shipment Only for Regions Other than EMEA amp I 4 3 2 Disks This section explains the installation rules for disks 2 5 disks The following table shows the priority order of 2 5 disk installation Table 4 3 Priority order of 2 5 disk installation Priority order Type Disk c
50. r ETERNUS DX Disk storage system Figure 3 5 Example of a LAN connection When using ETERNUS Web GUI to manage operations prepare a Web browser in the administration terminal The following table shows the supported Web browsers Table 3 2 ETERNUS Web GUI operating environment Software Guaranteed operating environment Web browser Microsoft Internet Explorer 6 0 7 0 8 0 Mozilla Firefox 3 0 x 3 5 x 3 6 x When using ETERNUS Web GUI to connect the ETERNUS DX Disk storage system the default port number is 80 for http or 443 for https LAN for operation management In an ETERNUS DX Disk storage system the system administrator logs on to the ETERNUS DX Disk storage system via a LAN to set the RAID configuration manage operations and perform maintenance The computer for operation management that is used for accessing the ETERNUS DX Disk storage system via ETERNUS Web GUI or ETERNUS CLI is called an administration terminal In addition the functions that are provided by the management monitoring server on the LAN can be used These functions include SNMP device monitoring SMTP e mail sending and NTP time correction ETERNUS DX60 S2 Disk storage system User s Guide Site Planning Copyright 2012 FUJITSU LIMITED P3AM 5492 04ENZO Chapter 3 Connections 3 3 Power Supply Connection 3 3 3 3 1 P LAN for remote support Various failures that occur in the ETERNUS DX Disk storage system are notified
51. raph Table 2 10 Power distribution unit 2U breaking characteristics Trip time sec Delay 100 125 150 200 400 600 800 1000 63 No Trip 50 to 30 to 10 to 1 5 to 0 4 to 0 013 to 0 013 to 700 400 150 20 10 0 85 0 5 ETERNUS DX60 S2 Disk storage system User s Guide Site Planning Copyright 2012 FUJITSU LIMITED 37 P3AM 5492 04ENZO Chapter 2 ETERNUS DX Disk Storage System Installation 2 6 Circuit Protectors ETERNUS DX Disk storage system DE 01 PSU PSU Ro a Ka CE a SES Power distribution unit a v V en CP CP Distribution Distribution board board To power supply facility To power supply facility CP Circuit Protector Figure 2 5 Example of a power supply connection using a power distribution unit 2U E For power distribution unit 1U connection The breaking characteristics of distribution board circuit protectors must be slower than the val ues shown in Figure 2 6 or equivalent to D IEC898 CURVE 200E 1000 100 10 DI TIME IN SECONDS 0 01 0 001 400 200 300 400 500 600 700 800 900 1000 150 PERCENT LOAD Figure 2 6 Power distribution unit 1U breaking characteristics graph ETERNUS DX60 S2 Disk storage system User s Guide Site Planning
52. rdware Configurations 1 1 Controller Enclosure Rear view e Single controller type LAN MNT port LAN RMT port PWC port Controller CM 0 Power supply unit Power supply unit PSU 1 PSU 0 Host interface ports 0 Left 1 Right DI OUT port Figure 1 2 Rear view of a 2 5 type controller enclosure single controller type e Dual controller type LAN MNT port LAN RMT port LAN MNT port LAN RMT port PWC port PWC port Controller CM 0 Controller CM 1 Power supply unit Power supply unit PSU 1 PSU 0 Host interface ports Host interface ports 0 Left 1 Right 0 Left 1 Right DI OUT port DI OUT port Figure 1 3 Rear view of a 2 5 type controller enclosure dual controller type 12 ETERNUS DX60 S2 Disk storage system User s Guide Site Planning Copyright 2012 FUJITSU LIMITED P3AM 5492 04ENZO Chapter 1 Hardware Configurations 1 1 Controller Enclosure Figure 1 4 Top view of a 2 5 type controller enclosure Top view Side view Figure 1 5 Side view of a 2 5 type controller enclosure P External views of a 3 5 type controller enclosure ole Gi 9000 0000 c000 9000 9090 9099 9000
53. rface port Figure 1 24 Enclosure connection path dual controller type A connection path is not duplicated in a single controller type DE DI Drive Interface port Figure 1 25 Enclosure connection path single controller type 21 ETERNUS DX60 S2 Disk storage system User s Guide Site Planning Copyright 2012 FUJITSU LIMITED P3AM 5492 04ENZO Chapter 1 Hardware Configurations 1 4 Disks 1 4 1 4 1 1 4 2 Disks The following disks can be installed in a controller enclosure and drive enclosure 2 5 Disks The following table shows the 2 5 disk specifications Table 1 6 2 5 disk specifications Disk name DI Storage media Storage capacity Speed 300GB 450GB 600GB SAS disks Hard disk i 10 000rpm Serial Attached 900GB H Nearline SCSI 3Gbit s l SAS disks Hard disk 1TB 7 200rpm 3 5 Disks The following table shows the 3 5 disk specifications Table 1 7 3 5 disk specifications Disk name DI Storage media Storage capacity Speed SAS disks Hard disk 300GB 450GB 600GB 15 000rpm heading Serial Attached earline F SCSI 3Gbit s SAS disks Hard disk 1TB 2TB 3TB 7 200rpm 22 ETERNUS DX60 S2 Disk storage system User s Guide Site Planning Copyright 2012 FUJITSU LIMITED P3AM 5492 04ENZO Chapter 1 Hardware Configurations 1 5 Power Distribution Units Only for Regions Other than EMEA amp I 1 5 P
54. s 54 4 2 1 Fujitsu RACKS oo eee eceeeeee ee eecee eee eeeeneeee sees aeaeeeeceaeeeeeeseeeeeseesceeaeeeeseeeeaeeeeseeeaaeeeseeaaeeeseeeaeees 54 4 2 2 NOM FUjItSU RACKS seeciccsedeceee EEN EAR EEAA E EENS shaded ctehdekaed Gstaad ane aae 54 4 3 Standard Installation Rules Before Shipment Only for Regions Other than EMEA amp I cceeceeeeeceeeeeeeeeeeeeeeeeeeeeeenneeeeeeenees 56 A321 Drive ENncloSunes gen eege 56 GM le EN 57 4 3 3 Disk Installation Examples 0 ccccccccceeeeeeeeeceec cae ceeeeeeeeeeececeeeaaaeaeeeeeeeeeeeseeseceeaaesaeeeeeeeeeeeeeneee 59 T ETERNUS DX60 S2 Disk storage system User s Guide Site Planning Copyright 2012 FUJITSU LIMITED P3AM 5492 04ENZO Figure 1 1 Figure 1 2 Figure 1 3 Figure 1 4 Figure 1 5 Figure 1 6 Figure 1 7 Figure 1 8 Figure 1 9 Figure 1 10 Figure 1 11 Figure 1 12 Figure 1 13 Figure 1 14 Figure 1 15 Figure 1 16 Figure 1 17 Figure 1 18 Figure 1 19 Figure 1 20 Figure 1 21 Figure 1 22 Figure 1 23 Figure 1 24 Figure 1 25 Figure 1 26 Figure 1 27 Figure 1 28 Figure 2 1 Figure 2 2 Figure 2 3 Figure 2 4 Figure 2 5 Figure 2 6 Figure 2 7 Figure 2 8 Figure 2 9 Figure 3 1 Figure 3 2 Figure 3 3 Figure 3 4 Figure 3 5 Figure 3 6 Figure 3 7 Figure 3 8 Figure 3 9 Figure 3 10 Figure 3 11 List of Figures Front view of a 2 5 type controller enclosure rennet ent 11 Rear view of a 2 5 type controller enclosure single controller bvpe 12 Rear view of a 2 5
55. s not meet the ambient environment conditions a temperature error occurs and the power of the ETERNUS DX Disk storage system is shut down Front intake air temperature Make sure that the front intake air temperature is between 5 and 40 C Rear exhaust air temperature For example when the intake air temperature is 40 C the exhaust air temperature is 45 C or higher Check the heat generation amount and the exhaust air amount that are listed in 2 1 Installation Specifications page 26 for the necessary cooling capacity of air conditioning Earthquake Resistance Take the necessary measures e g secure the rack to the floor or wall to prevent a rack in which an ETERNUS DX Disk storage system is installed from falling down when earthquakes occur Earthquake countermeasures vary depending on the installation location the floor conditions and the type of rack that is used Contact your installation contractor for more details regarding earthquake countermeasure methods and how work should be conducted ETERNUS DX60 S2 Disk storage system User s Guide Site Planning Copyright 2012 FUJITSU LIMITED P3AM 5492 04ENZO Chapter 2 ETERNUS DX Disk Storage System Installation 2 5 Outlet Socket Specifications 2 4 3 20 2 5 1 Load Bearing Capacity for Floors Make sure that the following relationship between the load bearing capacity of the floor and the weight of the ETERNUS DX Disk storage system is maintained Load beari
56. the main components and the relative optional products that are installed in the ETERNUS DX60 S2 Disk storage system Chapter 2 ETERNUS DX Disk Storage System Installation This chapter describes the installation specifications the installation environment and the power requirements Chapter 3 Connections This chapter describes the configuration for each interface to connect to the ETERNUS DxX60 S2 Disk storage system Chapter 4 Rack and Optional Product Installation This chapter describes the requirements for rack installation This chapter also describes the standard installation rules installation locations and installa tion order of the optional products before shipment from the factory when the optional prod ucts are purchased with the ETERNUS DX60 S2 Disk storage system at the same time Naming Conventions P Abbreviations used in this manual e ETERNUS DX Disk storage system refers to the ETERNUS DX60 S2 Disk storage system e Host Bus Adapter HBA refers to the interface module normally used by the server to connect to the ETERNUS DX Disk storage systems A FC card LAN card Network Interface Card NIC or SAS card may be used instead depending on the server and interface e Trademark symbols such as and are omitted in this document ETERNUS DX60 S2 Disk storage system User s Guide Site Planning Copyright 2012 FUJITSU LIMITED P3AM 5492 04ENZO About this Manual Warning Notatio
57. to the remote support center Remote support connection can be separated from the LAN for operation man agement Power Supply Connection Connect the power cords AC cables of the ETERNUS DX Disk storage system to the power sockets the UPS sockets or the power control unit sockets Refer to 2 5 Outlet Socket Specifications page 31 for details about the types and the number of power outlets sockets Two power supply units PSU 0 and PSU 1 are installed in each enclo E Note sure Make sure that power cords are connected to both of the power sup ply units Input Power Supply Lines Multiple power supply facilities in the building or UPS units are recommended for power supply redundancy When the ETERNUS DX Disk storage system power supply is redundantly config ured business can continue even if one of the power lines fails To connect the ETERNUS DX Disk storage system to power supply facilities use the following configurations to improve the availability of the power supply facilities if a power supply facility failure occurs e Connect the power cords of PSU 0 and PSU 1 to different lines e When a power distribution unit is used separately connect it to line O PSU 0 and line 1 PSU 1 Alternatively optimal system design including the server may instead lead to the ETERNUS DX Disk storage system being configured with only a single power supply facility or UPS unit Which configuration is selected will depend on
58. ts the Flow Control function disable the Flow Control function e When connecting to a server with VMware vSphere 4 0 4 1 disable the Flow Control function of the LAN switch E SAS Simple cost effective and high performance network storage environment can be configured Direct connections to servers are available The maximum transfer speed is 3Gbit s f Up to two paths are allowed when the ETERNUS Multipath Driver is used Caution D Host Connection Path This section explains the connection configuration between a server Host Bus Adapter HBA and an ETERNUS DX Disk storage system host interface port Single path configuration A single path configuration connects the ETERNUS DX Disk storage system to a server via a single path The server cannot access an ETERNUS DX Disk storage system when a component such as a controller HBA switch or cable on the path has a problem The system must be stopped during the replacement of failed components and controller firmware In a single path connection configuration the path failover and load balancing functions are not supported A multipath connection configuration is recommended to maintain availability when a problem occurs ETERNUS DX60 S2 Disk storage system User s Guide Site Planning Copyright 2012 FUJITSU LIMITED P3AM 5492 04ENZO Chapter 3 Connections 3 1 Host Connections Server Server HBA HBA oo ETERNUS
59. type controller enclosure dual controller type ccceeeeeeeeseeeeeeeeneees 12 Top view of a 2 5 type controller enclosure cee eeeeeeeeeeeeneeeceeeeeeeeeeeeeeceaaaaecaeeeeeeeeeteeeeeenaees 13 Side view of a 2 5 type controller enclosure ee eee eeeeeee eee eeeeeeeeeseeeeeeeeeseeeeeeeeteeenaeeeeeeentes 13 Front view of a 3 5 type controller enclosure with front Cover 13 Front view of a 3 5 type controller enclosure without front Cover 13 Rear view of a 3 5 type controller enclosure single controller bvpe 14 Rear view of a 3 5 type controller enclosure dual controller type cseeeeceeeeeneeeeeeeeneees 14 Top view of a 3 5 type controller enclosure saeesssssseeessesessrrssesennnessnnnnsntunnnnannnnunninannnnnnannnnean 15 Side view of a 3 5 type controller enclosure ssssssssseesrrssseerrrestirrrssttrrnsssttrnnnattnnnnstn nnns nnn 15 Host interface port FC model 2 2c cccceeeeseecedeeeeneeecsesencceeeeeeeneceeeeeseneceeesensnaceeeeensenseeeeenenneees 16 Host interface port iSCSI model 16 Host interface port SAS model cccccccccesecceeeeeccceeeeeeenaeeeeeeeaceeeeeeenaaeanenseaaeeeeeneecaaeeensenaeeeeeeees 16 Power supply unit controller enclosure 0 00 0 eect eeeeeeee teeter ee eee eaeeee eee taeeeeeeetaeeeeeetiaeeeenee 18 Front view of a drive enclosure with front Cover 18 Front view of a drive enclosure without front Cover 18 Rear view of a dr
60. urned off before the server shuts down Socket type If the power plug type and the socket type of the UPS do not match it is necessary to equip the UPS AC output with an appropriate type of socket Request a qualified electrician to perform the necessary work to make terminal block connections available Power supply configuration If a UPS is used make sure that it supplies power to all the enclosures Configurations where the controller enclosure is powered by the UPS while the drive enclosure is powered directly from AC are not supported ETERNUS DX60 S2 Disk storage system User s Guide Site Planning Copyright 2012 FUJITSU LIMITED P3AM 5492 04ENZO Chapter 3 Connections 3 4 Power Synchronized Connections 3 4 Power Synchronized Connections EES This section describes connections to automatically control powering the ETERNUS DX Disk storage system on and off with a server Power synchronized unit A power synchronized unit enables the ETERNUS DX Disk storage system to be powered on and off with a server The power synchronized unit detects changes in the AC power output of a UPS unit that is connected to a server server UPS unit and automatically turns on and off the ETERNUS DX Disk storage system In addition to server UPS units units that control the AC socket power output can also be connected When three or more servers are connected power can be synchronized by adding an AC sensor unit The power synchronize