Frymaster HCFU-42CF03 User's Manual

image

Contents

1. ig eiling a NAA habi 7 INDOOR UNIT ll e 7 ON NOO Onor a MO pA 7 Vy Na 3 80mm 6 150mm mie SILA IRI IIIT PISI PEG Z Z Z Wt UN Y liu 7 0 4 10mm over FOR HALF CONCEALED INSTALLATION Ceiling panel Fig 2 A Bs Z g E UA INDOOR UNIT Sa 7 C00 Ad ooi JA A r H a a a po ae 3 80mm 6 150mm over over Ceiling panel oe 7 Z 5 Z Z LLL Z Wit AN f lu 7 0 4 10mm k over 13 E Installation of Indoor Unit CONNECTION PIPE REQUIREMENT Table 1 Maximum height Diameter l Model between indoor Maximum Liquid side Gas side length and outdoor HCFU 42CF03 HCFU 42HF03 9 52 mm 19 05mm INSTALLATION PROCEDURE Install the room air conditioner as follows 1 REMOVE THE INTAKE GRILL AND SIDE COVER 1 Remove the Air filters 2 Remove the intake grilles 3 Remove the Side cover A Right and left side 4 This air conditioner can be set up to intake fresh air For information about how to install for Side cover A Right side Side cover A Left side fresh air intake refer to page 23 FRESH AIR INTAKE Intake grille 2 LOCATION OF CEILING SUSPENSION BOLTS Fig 3 30mm 30mm gt bu Dimensions Space Required for Suspension bolt pitch 1530mm installation 10mm 155mm Yt INDOOR UNIT TOP VIEW a 300mm ZZL EL Suspension bolt should extend outward 30
2. e Use the air direction adjustments within the ranges shown above E Features and Functions e The swing range of up down flap is as follow Air flow direction set Range of swing O O O t O O to to O to O toG all range e Each time the button is pressed the air direction range will change as follows Oe OS OS RIGHT LEFT lt air direction louvers Note When being switched on firstly the up down flap will be at the position of max angle In cooling the up down louver is not good to stay at position 4 5 for along time otherwise the dew will occur E Name of Parts a POWER OPER TIMER COMP Q Operating Control Panel Emergency switch Power Indicator Lamp OPERATION Indicator Lamp 6 TIMER Indicator Lamp Compressor Lamp Remote receiver Inlet Grill Filter inside Front panel E Cleaning and Care 1 Pull the filters upward to remove them from the Intake Grill 2 Clean the air filter Remove the dust from the filters by vacuum cleaner or washing them After washing allow the air filters to dry thoroughly in an area protected from sunlight 3 Re attach the air filters to the Intake Grill press the two buttons on the filters until you hear a sound of click e When used for extended periods the unit may accumulate di
3. 1 Install insulation for the drain pipe See Fig 12 and 13 Cut the included insulation material to an appropriate size and adhere it to the pipe Fig 12 0 a D g3 n ar N Drain pipe Insulation for Drain pipe To be obtained locally Length shoud be at least 8mm Drain pipe insulation accessories Indoor unit drain port Fig 13 Drain pipe insulation Indoor unit WA lt Y Drain pipe No gap 10mm or over 2 If Right rear piping fasten the drain pipe with VT wires so that the pipe slopes correctly within the indoor unit E Installation of Indoor Unit ELECTRICAL WIRING HOW TO CONNECT WIRING TO THE TERMINALS A For solid core wiring or F cable 1 Cut the wire and with a wire cutter or wire cutting pliers then strip the insulation to about 15 16 25mm of expose the solid wire 2 Using a screwdriver remove the terminal screw s on the terminal board 3 Using pliers bend the solid wire to form a loop suitable for the terminal screw B For strand wiring 1 Cut the wire and with a wire cutter or wire cutting pliers then strip the insulation to about 3 8 10mm of expose the solid wire 2 Using a screwdriver remove the terminal screw s on the terminal board Pagala A Solid wire B Strand wire f7 T Round terminal Ee Loop E S a sik z gt z mmy a a 2 H Insulation H na na Screw with special washer Screw with Round special wash
4. Lift unit so that suspension bolts pass through suspension fittings at the sides four places and slide the unit back See Fig 8 15 E Installation of Indoor Unit Fig 7 Fig 8 ji Ceiling N Ceiling panel H A Wall 2 Fasten the indoor unit into place by tightening up the special B blots and the M10 nuts Make sure that unit is secure and willl not shift back and forth FOR HALF CONCESLED INSTALLATION When installing the indoor unit in a semi concesled orientation make sure to reinforce the insulation of the unit on all sides Drops of water may fall from the unit if it is not thoroughly insulated Fig 9 Glass wool insulate 10 to 20mm thick T INDOOR UNIT Top view Wall Ceiling pannel CAUTION In order to check the drainage be sure to use a level during installation of the indoor unit If the installation site of the indoor unit is not level water leskage may occur E Installation of Indoor Unit INSTALLING THE COUPLER HEAT INSULATION After checking for gas leaks insulate by wrapping insulation around the two parts large and small of the indoor unit coupling using the coupler hest insulation After installling the coupler heat insulation wrap both ends with vinyl tape so that there is no gap Secure both ends of the heat insulation material using nylon fasteners Fig 10 Coupler heat insulation large Coupler
5. circuit will appliance operate briefly for about 7 to 12 minutes During Automatic Defrosting operation the by recirculating air throughout the room with the OPERATION ee result that some time may be required after first Trouble alarming performance starting the air conditioner until the room is heated During operation when there is any trouble e Heat pump air conditioners heat your entire room the operation indicator lamp will flash with different Instructions relating to heating are applicable dines only to HEAT amp COOL TYPE Temperature and Humidity Range SSS Rated Cooling 3 27 e outdoor e If the air conditioner is used under higher temperature condition than those listed the built in protection circuit may operate to prevent internal circuit damage Also during Cooling and Dry modes if the unit is used under conditions of lower temperature than those listed above the heat exchanger may freeze leading to water leakage and other damage e Do not use this unit for any other purposes except for the Cooling Heating Dehumidifying and air circulation of rooms in ordinary dwellings e The wiring method should be in line with the local wiring standand e The waste battery should be disposed properly e If the fuse on PC board is broken please change it with the type T 3 15A 250VAC e The indoor unit installation height is at least 2 5m 10 E Installation of Indoor Unit
6. drain normal 2 OUTDOOR UNIT 1 Is there any abnormal noise and vibration during operation 2 Will noise wind or drain water from the unit disturb the neighbors 3 Is there any gas leakage CUSTOMER GUIDANCE Explain the following to the customer in accordance with the operating manual 1 Starting and stopping method operation switching temperature adjustment timer air flow switching and other remote control unit operations 2 Air filter removal and cleaning and how to use air louvers 3 Give the operating and installation manuals to the customer 24 E Trouble Shooting Followings are not problems Sound of water flowing is not a problem Sound of cracking is heard Smell are generated During operation white fog or steam comes out from the indoor unit In cooling operation unit switches to blowing operation Unit will not restart after stop Won t start No outlet air or fan speed can t be changed in dry mode During unit operation or at stop a swishing or gurgling noise may be heard This noise is generated by refrigerant flowing in the system During unit operation a cracking noise may be heard This noise is generated by the casing expanding or shrinking because of temperature changes This is because the system circulates smells from the interior air such as the smell of cigarettes or the painting on the furniture When unit is running at places like restaurant etc wh
7. CONVERTIBLE CEILING FLOOR MOUNTING amp EXPOSED CEILING FLOOR MOUNTING AIR CONDITIONER Operation amp Installation Manual HCFU 42CF03 HCFU 42HF03 No 0010577270 e Please read this operation manual before using the air conditioner e Please keep this manual carefully and safely E Contents aa aca eel EE E T 12 Safety Precautions aanak sietnie tiea 3 4 Features and Functions 1 1 1 1 5 7 Name of Parts ika tcc cece se desea aaasaaa 8 Clean and Caba na aka 9 Operation Tipas ak nA GA 10 Installation of Indoor Unit 1111 11 14 11 24 Trouble Shooting sissi ere 25 26 E Cautions Disposal of the old air conditioner Before disposing an old air conditioner that goes out of use please make sure it s inoperative and safe Unplug the air conditioner in order to avoid the risk of child entrapment It must be noticed that air conditioner system contains refrigerants which require specialized waste disposal The valuable materials contained in a air conditioner can be recycled Contact your local waste disposal center for proper disposal of an old air conditioner and contact your local authority or your dealer if you have any question Please ensure that the pipework of your air conditioner does not get damaged prior to being picked up by the relevant waste disposal center and contribute to environmental awareness by insisting on an appropriate anti pollution method of disposal Disposal of the packaging of yo
8. E ee ae ii v OUTDOOR UNIT OUTDOOR UNIT FOWER SUPPLY TERMINIAL BLOCK TERMINIAL BLOCK 3N 380 400V 50Hz 3N 380 400V 50Hz HCFU 42CF03 HCFU 42HF03 N WARNING 1 Always use a special branch circuit and install a special receptacle to supply power to the room air conditioner 2 Use a circuit breaker and receptacle matched to the capacity of the room air conditioner 3 The circuit breaker is installed in the permanent wiring Always use a circuit that can trip all the poles of the wiring and has an isolation distance of at least 3mm between the contacts of each pole 4 Perform wiring work in accordance with standards so that the room air conditioner can be operated safely and positively 5 Install a leakage circuit breaker in accordance with the related laws and regulations and electric company standards E Installation of Indoor Unit CAUTION 1 The power source capacity must be the sum of the room air conditioner current and the current of other electrical appliances When the current contracted capacity is insufficient change the contracted capacity 2 When the voltage is low and the air conditioner is difficult to start contact the power company the voltage raised TEST RUNNING 1 CHECK ITEMS 1 INDOOR UNIT 1 Is operation of each button on the remote control unit normal 2 Does each lamp light normally 3 Do not air flow direction louvers operate normally 4 Is the
9. Economic Development Zone Qingdao Shandong 266500 P R China Web Site http www haier com
10. Please ask the dealer or specialist to install never try by the users themselves After the installation please be sure of the following conditions WARNING Please call dealer to install the air conditioner Incorrect installation may cause water leaking shock and fire hazard CAUTION e Air conditioner can t be installed in the envi ronment with inflammable gases because the inflammable gases near to air conditioner may cause fire hazard e Installed electrical leaking circuit breaker It easily cause electrical shock without circuit breaker Location e Air conditioner should be located in well vented and easily accessible place e Air conditioner should not be located in the following places a Places with machine oils or other oil vapours b Seaside with high salt content in the air c Near to hot spring with high content of sulfide gases d Area with frequent fluctuation of voltage e g factory etc e In vehicles or ships f Kitchen with heavy oil vapour or humidity g Near to the machine emitting electric magnetic waves h Places with acid alkali vapuor e TV radio acoustic appliances etc are at least 1 m far away to the indoor unit outdoor unit power 11 e Connect earthing wire Earthing wire should not be con nected to the gas pipe water pipe lightning rod or phone line in correct earthing may cause shock D Earthing Use discharge pipe correct
11. d in accordance with specifications e Always remember to unplug the air conditioner before opening inlet grill page8 Never unplug your air conditioner by pulling on the power cord Always grip plug firmly and pull straight out from the outlet e All electrical repairs must be carried out by qualified electricians Inadequate repairs may result in a major source of danger for the user of the air conditoiner e Do not damage any parts of the air conditioner that carry refrigerant by piercing or perforating the air conditioner s tubes with sharp or pointed items crushing or twisting any tubes or scraping the coatings off the surfaces If the refrigerant spurts out and gets into eyes it may result in serious eye injuries e Do not obstruct or cover the ventilation grille of the air conditioner Do not put fingers or any other things into the inlet outlet and swing louver Do not allow children to play with the air conditioner In no case should children be allowed to sit on the outdoor unit e The refrigerating circuit is leak proof E Safety Precautions A WARNING e The breaker of the air conditioner should be all pole switch and the distance between its two contacts should be no less 3mm Such means for disconnection must be incorporation in the fixed wiring e Use copper wire only All the cables shall have got the European authentication certificate e For these units the power supply connects from the outdo
12. er terminal Round Terminal z terminal board Wire HOW TO FIXED CONNECTION CORD AND POWER CABLE AT THE CORD CLAMP After passing the connection cord and power cable through the insulation tube fasten it with the cord clamp as shown in Fig 15 20 E Installation of Indoor Unit ELECTRICAL REQUIREMENT e Electric wire size and fuse capacity Table 5 ak HCFU 42CF03 erles HCFU 42HF03 Connection MAX 3 5 cord Fuse capacity A 30 Fig 15 a Insulation tube Cord clamp Use VW 1 0 5 to 1 0 mm thick PVC tube as the insulation tube N CAUTION 1 Match the terminal block numbers and connection cord colors with those of the outdoor unit Erroneous wiring may cause burning of the electric parts 2 Connect the connection cords firmly to the terminal block Imperfect installation may cause a fire 3 Always fasten the outside covering of the connection cord with the cord clamp If the insulator is chafed electric leakage may occur 4 Always connect the ground wire 21 E Installation of Indoor Unit FRESH AIR INTAKE 1 Open up the knockout hole for the fresh air intake as shown in Fig 16 If using half concealed installation open up the top knockout hole instead Fig 16 For half concealed N CAUTION 1 When removing the cabinet iron plate be careful not to damage the indoor unit internal parts and surrounding area outer case 2 When proces
13. ere dense edible oil fumes always exist this will happen To prevent frost from accumulating on indoor heat exchanger unit will switch to blowing operation for a while then resume cooling operation Though ON OFF button is set to ON unit won t resume cooling dry or heating operation in 3 min after it is stopped this is because of 3 min delay protection circuit PN Please wait 3 minutes Unit will reduce fan speed repeatedly and automatically if room temp is too low in dry operation In heating operation water or steam are blown out of outdoor unit a In heating operation indoor fan won t stop even if unit is stopped This occurs when frost accumulated on the outdoor unit is removed during defrosting operation After unit stop indoor fan will go on running until indoor unit cools down 25 E Trouble Shooting Before ask for services please first check your unit against the following Air conditioner won t start Is power supply switch turned on Si Power supply switch Are operation control Is air filter too dirty adjusted correctly z PD as specified mg Are horizontal louvers atup Any doors or windows left position in heating mode open Poor cooling Is there any direct sunlight If there are unexpected heat in the room Bal sources in the room Ta Cold air blows out in heating mode Is air conditioner in standby co
14. ir conditioner e Do not expose the air conditioner directly to water e Do not operate the air conditioner with wet hands e Do not pull power supply cord e Turn off power source when not using the unit for extended periods e Check the condition of the installation stand for damage e Do not place animals or plants in the direct path of the air flow e Do not drink the water drained from the air conditioner e Do not use in applications involving the storage of foods plants or animals precision equipment or art works e Do not apply any heavy pressure to radiator fins e Operate only with air filters installed e Do not block or cover the intake grill and outlet port e Ensure that any electronic equipment is at least one metre away from either the indoor or outdoor unit e Avoid installing the air conditioner near a fireplace or other heating apparatuses e When installing the indoor and outdoor unit take precautions to prevent access to infants e Do not use inflammable gases near the air conditioner E Features and Functions a M a a ee S AUTOMATIC OPERATION e COOLING TYPE Merely press the ON OFF button and the unit will begin automatic operation in the Cooling or dry modes as appropriate in accordance with the thermostat setting and the actual temperature of the room e HEAT amp COOL TYPE Merely press the ON OFF button and the unit will begin automatic operation in any of the Heating Cooling and Blo
15. l all installation work is done e Be careful not to scratch the room air conditioner when handing it After installation explain correct operation to the customer according to the operating manual e Let the customer keep this installation manual because it will be used when the room air conditioner is serviced or moved 1 SELECTING THE MOUNTING POSITION A WARNING e Install at a place that can withstand the weight of the indoor unit and install it positively so that the unit will not topple or fall A CAUTION Do not install the unit where there is the danger of combustible gas leakage e Do not install near heat sources If children under 10 years old may approach the unit take preventive measures so that they cannot reach the unit 12 E Installation of Indoor Unit 1 Install the indoor unit level on a strong wall which is not subject to vibration 2 The inlet and outlet ports should not be obstructed the air should be able to blow all over the room 3 Do not install the unit where it will be exposed to direct sunlight 4 Install the unit where connection to the outdoor unit is easy 5 Install the unit where the drain pipe can be easily installed 6 Take servicing etc into consideration and leave the spaces shown in Fig 1 or 2 Also install the unit where the filter can be removed
16. ly to ensure efficient discharge Incorrect pipe use may cause water leaking supply wire connecting wire pipes otherwise images may be disturbed or noises be created e As required take measures against heavy snow Wiring e Air conditioner should be equipped with special power supply wire Operating noise e Choose the following locations a Capable of supporting air conditioner weight don t increase operating noise and vibration b Hot vapour from outdoor unit outlet and ope rating noise don t disturb neighbour e No obstacles around the outdoor unit outlet E Installation of Indoor Unit For authorized service personnel only A WARNING 1 For the room air conditioner to operate satisfactorily install it as outlined in this installation manual 2 Connect the indoor unit and outdoor unit with the room air conditioner piping and cords available from our standard parts This installation manual describes for the correct connections so that the installation set available from our standard parts should be used 3 Installation work must be performed in accordance with national wiring standards by authorized personnel only 4 Never cut the power cord lengthen or shorten the cord or change the plug 5 Also do not use an extension cord 6 Plug in the power cord plug firmly If the receptacle is loose repair it before using the room air conditioner 7 Do not turn on the power unti
17. ndition in heating mode Is city power supply normal Is leakage current breaker activated GP This is very dangerous please disconnect power supply immediately and contact your is not set at ON dealer Are there any obstacles in inlet or outlet grill Too many people in the room dca as A NONE If your unit still can t work properly after above mentioned checks or following problems occur please stop it immediately and contact your dealer e Fuses or circuit breakers often blow out e Water comes out in cooling dry operation e Operation is abnormal or sound is heard Error display Failure description Room temp sensor abnormal Indoor coil temp sensor abnormal Outdoor temp sensor abnormal Outdoor coil temp sensor abnormal Over current malfunction High Low pressure abnormal or Comp discharging protection malfunction Communication malfunction between indoor and wired controller Communication malfunction between indoor and outdoor abnormal Temperature protection malfunction 26 Flash times of indoor receiver board Power LED flashes 1 time Power LED flashes 2 times Power LED flashes 3 times Power LED flashes 4 times Power LED flashes 5 times Power LED flashes 16 times Power LED flashes 8 times Power LED flashes 9 times Power LED flashes 13 times HAIER GROUP Qingdao Haier Air Conditioner Electric Co Ltd Address Haier Garden Qianwangang Road
18. or side The connecting cable are self provided e The parameter of connecting cable HCFU 42CF03 4G 1 0mm HCFU 42HF03 6G 1 0mm e The requirement of the cross section area of the power supply cord 3N 380 400V 50Hz HO7RN F 5G 2 5mm A DANGER e Do not attempt to install this air conditioner by yourself e This unit contains no user serviceable parts Always consult authorized service personnel for repairs e When moving consult authorized service personnel for disconnection and installation of the unit e Do not become excessively chilled by staying for lengthy periods in the direct cooling airflow e Do not insert fingers or objects into the outlet port or intake grills Do not start and stop air conditioner operation by connecting and disconnecting the power supply cord and so on e Take care not to damage the power supply cord If the supply card is danaged it must be replaied by the manufacturer or authoried service agent in order to avoid a hazard e In the event of a malfunction burning smell etc stop operation immediately turn off the circuit breaker and consult authorized service personnel E Safety Precautions A WARNING e Provide occasional ventilation during use e Do not direct air flow at fire places or heating apparatuses e Do not climb on and place objects on the air conditioner e Do not hang objects from the indoor unit e Do not set flower vases or water containers on top of the a
19. pipe large Ju Ind it ag aap 777777771177217 1271 72 Coupler pipe small 7777777777 ZI ITTITITIIN 4 Coupler heat insulation small Nylon fastner large No gap KS li ae Ss 3 Indoor unit NI LA Coupler heat insulation Nylon fastner small When using an auxiliary pipe make sure that the fastener used is insulated in the sane way N Notice When installing the unit on the floor fix the four rubber base feet in the accessories on the bottom plate of the unit with four 4x16 screws and 4 flat washers as the position in the figure rubber base foot The bottom plate of the unit flat washer E Installation of Indoor Unit DRAIN PIPING Install the drain pipe with downward gradient 1 50 to 1 100 and so there are no rises or traps in the pipe Use general hard polyvinyl chloride pipe VP25 outside diameter 38 mm During installation of the drain pipe be careful to avoid applying pressure to the drain point of the unit When the pipe is long install supporters Fig 11 Do not perform air bleeding Always heat insulate 8mm or over thick the indoor side of the drain pipe Fig 11 4 Pad Kam PILL ES S EL PP SS PP BI PPEPP PILLS S PLS BAD j x PAR x TIAN Supporter 5 to 6 5 ft 1 5 to 2m 18 E Installation of Indoor Unit
20. rt inside which reduces its performance We recommend that the unit is inspected regularly in addition to your own cleaning and care For more information consult authorized service personnel e When cleaning the unit s body do not use water hotter than 40 C harsh abrasive cleansers or volatile agents like benzene or thinner e Do not expose the unit body to liquid insecticides or hairsprays e When shutting down the unit for one month or more first allow the Fan mode to operate continuously for about half a day to allow internal parts to dry thoroughly E Operation Tips Operation and Performance Microcomputer controlled Automatic Defrosting Heating Performance e When using the Heating mode under conditions of low outdoor air temperature high humidity frost may form on the outdoor unit resulting in reduced operating performance e This air conditioner operates on the heat pump principle absorbing heat from outdoor air and transferring that heat indoors As a result the operating performance is reduced as outdoor air T al eIn order to prevent this kind of reduced performance this unit is equipped with a Microcomputer controlled Automatic Defrosting temperature drops If you feel that insufficient heating perfomance is being produced we recommend you use this air conditioner in function If frost forms the air conditioner will conjunction with another kind of heating temporarily stop and the defrosting
21. sing the cabinet iron plate be careful not to injury yourself with burrs etc 2 Fasten the round flange optional to the fresh air intake as shown in Fig 17 If using half concealed installation attach to the top Fig 17 Round duct option parts After completing INDOOR UNIT INSTALLATION 3 Connect the duct to the round flange 4 Seal with a band and vinyl tape etc so that air does not leak from the connection Fig 18 papa E Installation of Indoor Unit Wiring Connection 1 Remove the cord clamp 2 Process the end of the connection cords to the dimensions shown in Fig 19 3 Connect the end of the connection cord fully into theterminal block 4 Fasten the connection cord with a cord clamp 5 Fasten the end of the connection cord with the screw 6 The power cable and connecting cable are self provided 7 L N and 1 2 are equal on the terminal block Note Connect the black terminal of indoor unit with the black terminal of outdoor unit pro perly using the connecting wire which has both white terminals in the accesory bag and connect the blue terminal of indoor unit with the white terminal of out terminal as the same For heat pump model For cooling only unit just connect the black terminal of indoor unit with the black terminal of outdoor unit properly Fig 19 INDOOR UNIT INDOOR UNIT 3 TERMINIAL BLOCK W BI RIY G TERMINIAL BLOCK Y G Co R SIT N K
22. to 50mm For half concealed installation Supension bolt pitch should be as shown in Fig 4 Fig 4 40mm Ceiling Opening 1530mm 40mm a gt la 177 Ceiling panel gall E TR eT i ei et Dj Ceiling Opening 640mm 15mm ETA A Fa Suspension bolt should lq extend outward 30 to 50mm VA SSS Ceiling panel 14 Installation of Indoor Unit 3 DRILLING THE HOLES AND ATTACHING THE SUAPENSION BOLTS 1 Drill e amp 5mm holes at the suspension bolt locations The two special nuts are provided with the unit The M10 nut must be obtained locally Refer to Fig 5 2 Install the bolts then temporarily attach Special nuts A and B and a normal M10 nut to each bolt Bolt Strength 980 to 1470 N 100 TO 150 kg Special nut A included Ceiling panel Deol Mewes 10 to 15 mm Special nut B included M10 nut Obtained locally IF USING ANCHOR BOLTS 1 Drill holes for anchor bolts at the locations at which you will set the suspension bolts Note that anchor bolts to be obtained locally 2 Install the anchor bolts then temporarily attach special nut B included and a locally procurde M10 nut to each of the bolts See Fig 6 Anchor Bolt Strength 980 to 1470 N 100 TO 150 kgf Fig 6 Special nut B included M10 Nut Obtaied locally 10 to 15 mm M10 Nut LE Obtaied locally kaa INSTALLING THE INDOOR UNIT 1
23. ur new air conditioner All the packaging materials employed in the package of your new air conditioner may be disposed without any danger to the environment The cardboard box may be broken or cut into smaller pieces and given to a waste paper disposal service The wrapping bag made of polyethylene and the polyethylene foam pads contain no fluorochloric hydrocarbon All these valuable materials may be taken to a waste collecting center and used again after adequate recycling Consult your local authorities for the name and address of the waste materials collecting centers and waste paper disposal services nearest to your house Safety Instructions and Warnings Before starting the air conditioner read the information given in the User s Guide carefully The User s Guide contains very important observations relating to the assembly operation and maintenance of the air conditioner The manufacturer does not accept responsibility for any damages that may arise due to non observation of the following instruction e Damaged air conditioners are not to be put into operation In case of doubt consult your supplier e Use of the air conditioner is to be carried out in strict compliance with the relative instructions set forth in the User s Guide Installation shall be done by professional people don t install unit by yourself E Cautions e For the purpose of safety the air conditioner must be properly grounde
24. w modes as appropriate in accordance with the thermostat setting and the actual temperature of the room SLEEP e COOLING TYPE When the SLEEP button is pressed during Cooling or Dry mode the thermostat setting gradually rises during the period of operation When the set time is reached the unit automatically turns off e HEAT amp COOL TYPE When the SLEEP button is pressed during Heating mode the air conditioner s thermostat setting gradually lowers during the period of operation When the set time is reached the unit automatically turns off WIRELESS REMOTE CONTROL UNIT e The WIRELESS REMOTE CONTROL UNIT allows convenient control of air conditioner operation For this type unit the wireless remote controllor type is YR H50 MILDEW RESISTANT FILTER e The AIR FILTER has been treated to resist mildew growth thus allowing cleaner use and easier care E Features and Functions VERTICAL AIR DIRECTION ADJUSTMENT Press the AIR FLOW DIRECTION VERTICAL SET button e Each time the button is pressed the air direction range will change as follows Cool Dehumidification Fan O a a A Heat Ga gt gt Q go eUse the air direction adjustment within the ranges shown above eThe vertical airflow direction is set automatically as shown in accordance with the type of operation selected HORIZONTAL AIR DIRECTION ADJUSTMENT Press the AIR FLOW DIRECTION HORIZONTAL SET button