Home
Frigidaire FFTH0822Q1 Product Specifications Sheet
Contents
1. wall thickness e For energy saving purposes install unit in shady location preferably a northern exposure and do not block airflow inside with blinds curtains or furniture or outside with shrubs enclosures or other buildings FRIGIDAIRE USA 10200 David Taylor Drive Charlotte NC 28262 1 800 FRIGIDAIRE frigidaire com CANADA 5855 Terry Fox Way Mississauga ON L5V 3E4 1 800 265 8352 frigidaire ca FFTHO822Q1 01 14 Inside closure panel Home Comfort FFTHO822Q1_ Through The Wall Air Conditioner Heater Through The Wall Installation Wall thickness 18 max 7 Plug Type NEMA 5 15P Replacement Installation e When replacing existing air conditioner with new unit refer to Product Installation Guide on web to identify existing wall sleeve manufacturer and size compatibility If proper installation and slope are suspect then correct installation of Frigidaire Through The Wall 18 Sleeve Kit PN EA108T recommended e Use of existing wall sleeve to mount new unit requires original sleeve be in sound structural condition with rear grille that attaches securely or rear flange that serves as stop for unit e Preferable installation option for increased efficiency and possibility of drafts reduced requires existing rear grille mounted to sleeve be replaced with new unit s rear air directional louvered grille orovided in accessory k
2. FRIGIDAIRE Home Comfort FFTHO822Q1 Through The Wall Air Conditioner Heater Product Dimensions Height 14 1 2 Width 24 Depth 20 1 2 A Signature Features Effortless Temperature Control Our air conditioners maintain the preset room temperature so you will remain comfortable at all times Programmable 24 Hour On Off Timer With the 24 Hour On Off Timer you can ensure your home will be cool and comfortable when you want it to be without having to worry about running up your utility bills The built in timer allows you to preset the unit to turn on and off in half hour increments Energy Saver Mode Reduce your utility bills in this mode It cools similarly to central air with the unit turning on and off at different intervals to ensure the room temperature stays at the set temperature Multi Speed Fan Features three different fan speeds for more cooling flexibility More Easy To Use Features Supplemental Heating Option With our supplemental heating capability you can be comfortable regardless of the temperature outside you have both heating and cooling solutions Sleep Mode With Sleep Mode the temperature gradually increases a few degrees over the evening saving energy and creating a comfortable environment during the evening hours Remote Control Offers you the flexibility to control the temperature and fan speed from anywhere in the room Effortless Clean
3. Filter Our antibacterial filter reduces bacteria room odors and other airborne particles for a healthier more comfortable environment Power Cord Comes with an extra long three prong cord makes extension cords unnecessary Effortless Restart Automatically resumes operating at its previous settings when power is restored to your unit Clean Filter Alert Alert notifies you when your filter needs to be cleaned so you don t have to keep track of it yourself Ready Select Controls Easily select options with the touch of a button Performance BTUs Cool 8 000 Heat 4 200 frigidaire com FRIGIDAIRE Performance BTU Cool 8 000 BTU Heat 4 200 Dehumidification Pints Hour 18 Cool Area Up To Sq Ft 350 Energy Efficiency Ratio 9 0 Electrical Volts 115 Amps Cool 8 0 Amps Heat 12 0 Watts Cool 850 Watts Heat 1 250 Length of Power Cord Min Max 6 6 5 Plug Type NEMA LCDI 5 15P Features Electronic Controls Ready Select Controls Fan Speeds Cool Fan Heat 3 3 Low Voltage Start Up Yes Auto Cool Function Yes Energy Saver Mode Yes Sleep Mode Yes Filter Check p Yes 24 Hour On Off Timer Yes Clean Air lonizer Remote Control Full Function with Heat Air CFM High Med Low 273 223 206 Air Direction Control 4 Way Fresh Air Exhaust Vent Closed No No Yes Fil
4. ducts Inc Accessories information available on the web at frigidaire com Specifications subject to change FRIGIDAIRE 201 Through The Wall 18 Sleeve Kit PN EA108T Outside closure panel Adjustable lt lt mounting brackets Sleeve to unit seal Building construction support Home Comfort Specifications e Product Shipping Weight approx 74 Lbs An electrical supply with grounded three prong receptacle is required The power supply circuit must be installed in accordance with current edition of National Electrical Code ANSI NFPA 70 and local codes amp ordinances e Voltage Rating 15V 60 Hz 15 Amps e Amps 115 Volts Cool 8 Amps Heat 12 0 Amps e Recommended Circuit Breaker 15 Amps e Unit equipped with 115V 3 wire power supply cord NEMA plug type 5 15P approximately 72 long e Unit s increased performance characteristics result from two rear intakes For unit to operate at maximum efficiency carefully follow complete detailed new or replacement installation instructions provided in Product Installation Guide on web e Unit requires rearward slope when installation is complete to allow condensate to drain from rear of sleeve New Installation e For new installation Frigidaire Through The Wall 18 Sleeve Kit PN EAI08T available Recommended for proper installation Through the wall installation requires 18 maximum
5. it shipped with unit Non preferable installation option of directly mounting rear louvered grille to unit can be considered requiring grille be mounted to unit prior to sleeve installation e Existing decorative exterior grille may be left in place provided that proper air directional rear louvered grille is installed e For installation into larger existing sleeve optional Trim Kit PN EAI20T available Note For planning purposes only Refer to Product Installation Guide on the web at frigidaire com for detailed instructions Optional Accessories e Through The Wall 18 Sleeve Kit PN EAIO8T Trim Kit for larger existing sleeve PN EA120T e Architectural Style Exterior Louvered Grille PN EA109T Aus Specifications subject to change 2014 Electrolux Home Products Inc
6. ter Type Antibacterial Mesh Filter Access Slide Out Slide Out Chassis Warranty Yes Optional Accessories Through The Wall 18 Sleeve Kit PN EA108T Trim Kit for larger existing sleeve PN EA120T Architectural Style Exterior Louvered Grille PN EA109T Certifications Performance AHAM Specifications Refrigerant R4l0a E 74 Lbs Shipping Weight Approx Warranty 5 year sealed system 1 year full parts and labor Plug Type NEMA 5 15P FRIGIDAIRE FFTHO822Q1 Home Comfort Through The Wall Air Conditioner Heater Through The Wall 18 Sleeve Kit Adjustable mounting brackets Sleeve to unit seal Building construction support NOTE For planning purposes only Always consult local and national electric codes Refer to Product Installation Guide for detailed installation instructions on the web at frigidaire com Product Dimensions PN EA108T Outside closure panel Inside closure panel c UL us Sleeve Cutout Dimensions A Height PJA Height 15 5 8 B Width 24 Width 25 15 16 C Depth 20 1 2 D Max Wall Thickness 18 USA 10200 David Taylor Drive Charlotte NC 28262 1 800 FRIGIDAIRE frigidaire com CANADA 5855 Terry Fox Way Mississauga ON L5V 3E4 1 800 265 8352 frigidaire ca FFTHO822Q1 01 14 2014 Electrolux Home Pro
Download Pdf Manuals
Related Search
Related Contents
Kvaser Eagle User's Guide LMU 116 - Magtrol version 0.9.1 - Radioprotection Cirkus KingSpec 128GB 2.5" PATA/IDE : Free Download, Borrow, and Streaming : Internet Archive Surftest SV-600 - RDR Electronics Inc coef3768 - KOREA Mtt ioLogik E2212 Series User`s Manual Aéro Club de Saverne Steinbourg - L`aéro istruzioni per l`uso prima di usare il piano cottura vetroceramico Copyright © All rights reserved.
Failed to retrieve file