Home
Friedrich Fan BR1224W3A User's Manual
Contents
1. d FRIEDRICH 1883 Breeze A revolution in room cooling Installation Instructions for BR1224W3A 12000 24000 Btu Friedrich Part No 96091001 What s in the carton Accessories 1 Breeze indoor module with 25 ft connecting ITEM DESCRIPTION QTY line attached CONTROL BOX COVER DOOR 1 1 i A CONTROL BOX COVER 1 2 Wall mounting template and bracket for in 3 QUICK CONNECT COVER door module A WIRE TIE 2 3 Breeze outdoor module 5 CONNECTING LINE BENDING GUIDE 1 b ELECTRICAL CORD RETENTION BRACKET 1 4 Outdoor module connection covers E P E ace l 3 Mounting pad for outdoor module 8 OUTDOOR UNIT ANCHOR SCREW 4 6 Remote control 9 OUTDOOR UNIT WASHER FOR ANCHOR SCREW 4 7 Accessories see list at right 10 SCREW 8 X 3 4 TRUSS HEAD 6 11 SCREW 6 19X 375 HEX HEAD 1 12 WALL ANCHOR FOR 8 X 1 1 2 SCREW 15 Tools you will need 13 SCREW 8 X 1 1 2 PHILLIPS PAN HEAD 15 5 14 CONNECTING LINE CLIPS 5 Phillips screwdriver 1 2 wrench or crescent wrench Drill with Phillips bit and 3 16 drill bit Stud finder recommended 3 hole saw through wall installations Safety glasses recommended Trim knife Level Before getting started NOTE Identify the locations where you will mount the indoor Be sure to place your module and place the outdoor module Keep in mind equipment with these f ae limitations in mind there is 25 of connection line for connecting indoor and outdoor piece
2. S oO M SS Depending on the type of window install the appropriate security lock as recom mended by manufacturer STEP 4 Line set installation 4 1 Option 1 3 hole pass through Completely uncoil the line set as straight as possible Starting with the quick connect end of the line set pass the entire length through the 3 hole Before installation break small plastic knockout on side of indoor unit for power cord to pass through see Step 3 Figure 3 1 4 2 Option 2 SimpleSill window installation Uncoil enough of the line set to completely pass through the SimpleSill Pre bend the line set using the enclosed template to match the desired shape as It passes through the SimpleSill Place remaining coiled line set outside the window for later connection to the outdoor unit Break full plastic knockout for line set to pass through the side of the indoor unit see Step 3 Figure 3 2 STEP 5 Hang the indoor module on the wall bracket Hang the module at the top first and rotate it down until the module Is level with the wall You may need to make adjustments to the connecting line to get the indoor module to mount cleanly The Breeze module is not designed to mount totally flush to the wall A space of 1 8 to 3 8 may be present between the module and the wall The line set will sit in the recess of the back of the indoor unit when mounted STEP 6 Place the mounting pad Position the mounting pad
3. conditioner or heat pump to maintain the desired set point Pressing this button prompts the unit to take a reading of the room conditions Press to set the CLOCK CLOCK icon will flash when ready to set Use V A to set proper time Press to set the time for the unit to come on Optional setting only operates when ON icon is illuminated on remote Press to turn on the AUTO AIR SWEEP function or to set the desired angle of the airflow Airflow angle is reset each time power is turned off When on oo will be displayed In Cooling and Dry mode this will allow the unit fan to operate for 10 extra minutes after satisfying the temperature set point Press TEMP button to toggle between displaying the set point or room temp on the Breeze unit display Press to set the time for the unit to turn off Optional setting only j operates when OFF icon is illuminated on remote FRIEDRICH TURBO mode operates the unit at maximum performance level to bring the room to the set point temperature as rapidly as possible Available in Cooling and Heating mode m Press to enter SLEEP mode G SLEEP mode automatically adjusts the set point by 2 degrees after the first hour of operation to provide greater comfort overnight as well as save energy Turns the LIGHT on the Breeze unit on or off Special Features LOCK Fahrenheit Celsius You can lock the remote control by pressing the W and A simultaneo
4. of trained skilled worker where necessary Option 1 Drill hole Through the Wall Installation Drill 3 hole through the exterior wall NOTE This should only be done by qualified install ers Consult local and national codes before drilling any holes Mark the hole location on the indoor wall using the template If locating unit above a window or door make sure the hole is above structural header Using a stud finder scan area around desired hole loca tion for pipes ducts electrical conductors and struc tural elements Relocate indoor unit mounting location as necessary to avoid interference Using a 3 hole saw drill hole through wall from inside toward outside When hole saw cuts through Inside wall stop drilling DO NOT drill the entire 3 hole from the inside to prevent insulation and exterior wall damage Depending on the type of Insulation it might be neces sary to trim excess Insulation prior to completing the hole Once Insulation is removed continue drilling from inside until center drill bit of the saw just penetrates the outside wall TIP Tape a bag to the wall directly below hole location to catch drill debris and dust or use a shop vacuum while drilling Complete 3 hole from outside of the home by locating center spiral drill bit penetration Using the 3 hole saw finish drilling through the wall from the outside of the home NOTE Wall mount bracket ships mounted to the back of the ind
5. so that the mounting holes are away from the house Set the outdoor module on the mounting pad so that the module feet align with the mounting holes Screw the outdoor module to the mounting pad with the 4 condenser pad installation washers and screws provided Items 8 and 9 in the Accessories List STEP 7 Connect the quick connector from the indoor line set outdoor module Open lock handle on line 2 Grasp outer lock collar on While holding outer lock 4 Continue to push line set set connector by pulling line set connector and pull collar rearward push line connector onto base con back and rotating toward back until it stops set connector body over nector until outer lock col indoor unit base connector on outdoor lar engages base connector unit half way and release The outer lock collar will outer lock collar Snap into position with base connector and a click will be heard 5 Grasp lock handle and Install security screw _ rotate to its closed posi Item 13 in the Accessories tion List to prevent tampering with line set connector mechanism If you have excess connecting line roll the line into a coil approximately 2 feet wide secure with the provided wire ties and store between the outdoor module and the wall DO NOT cut or kink the connecting line STEP 8 Connect the electrical connector from the connecting line to outdoor module 1 Connect the black colored electrical connector from the connecti
6. ard for the entire length of the hose If the connecting line is rolled to store the excess line as shown in Step 6 the drain line may be removed from the connecting line as shown below and cut to an appropriate length STEP 10 Final Preparation Using the supplied connecting line clips Item 14 in the Accessories List secure the connecting line to the interior and exterior walls as desired 5 retaining clips are provided from the factory along with standard 8 x 1 1 2 screws and wall anchors SCORE AND PEEL For installations with the connecting line going through the wall option 1 use the supplied filler gasket Item 7 in the Accessories List to plug the hole around the connecting line in the wall opening Additional sealing may be desired or necessary for proper weatherproofing Once the connecting line is secure and Steps 1 9 are complete you LA may plug in the Breeze system and enjoy your new air conditioner STEP 9 Peel away Routine Maintenance Cleaning the unit The outer cover of the Breeze indoor module can be cleaned with a damp cloth Cleaning the outdoor module can be done by rinsing the module with low pressure water Refer to friedrich com for approved coil cleaning agents Cleaning the filter The indoor module of the Breeze system has a washable filter that should be inspected and cleaned periodically To access and clean the filter follow these steps 1 Open the front panel by pul
7. d national codes when installing equipment Obtain the help of trained skilled worker where necessary STEP 1 Determine how you will connect the indoor and outdoor modules There are two options available OPTION 1 is to drill a 3 hole through the wall to pass OPTION 2 is to use the Friedrich SimpleSill kit to pass the connecting line through the connecting pipe through the window The Simple SiLL is an optional accessory available where Breeze is sold Now that you have determined where the modules will be placed it is time to install the Breeze air conditioning system STEP 2 Hang wall mount bracket Using the paper template as a guide locate two studs behind screw hole locations in the template It is preferable to mount the hanging plate on studs If two studs are not available utilize anchors appropriate for the wall type with a combined weight capacity of at least 60 lbs Standard wood screws and drywall anchors are provided If you are installing the system by drilling a 3 hole through the wall Option 1 mark the location of the 3 hole centerline on the wall as well Note that the indoor unit is not centered on the bracket There is a center line on the paper template which shows where the center of the indoor unit will be after installation STEP 3 Drill hole Option 1 or mount SimpleSill Option 2 Always follow all local and national codes when in stalling equipment Obtain the help
8. ling on the left and right side tabs The front panel will open upward and lock into the open position 2 Remove the left and right air filters from the Breeze module 3 Wash the filters by rinsing with water or by vacuuming the dirt from the filter Allow the filter to dry completely prior to reinstalling 4 Reinsert both air filters Then lower the front panel and snap the panel into place Remote Control Operation 13 START STOP V A Arrow FAN AUTO MODE SENSOR CLOCK TIMER ON AIR SWEEP EXTEND TEMP TIMER OFF TURBO SLEEP LIGHT Turns the Breeze unit on or off Press to raise or lower the temperature setting Temperature setting range is between 61 F 86 F Adjusts the fan speed or sets fan to AUTO operation Selectable speeds are LOW MEDIUM HIGH or AUTO AUTO will automatically adjust the fan speed to maintain the proper set point Selects the Breeze operating mode Select between COOLING F HEATING amp DRY a s FAN F or AUTO COOLING mode the unit will operate as an air conditioner to maintain the desired set point HEATING the unit will operate as a heat pump to maintain the desired set point DRY s the unit will operate as an air conditioner on low speed to reduce humidity levels while not affecting the air temperature as greatly FAN F the unit will operate as a fan to circulate air only AUTO the unit will operate as an air
9. ng line into the mating connector on the outdoor module The connectors will snap into place with a click The plug can be removed by pushing in the side tabs on the plug and pulling the plug body down and out of the receptacle een ate 2 Install the electrical cord retention bracket Item 6 in the Accessories List using ltem 10 two 8 x 3 4 screws Item 10 in the Accessories List The opening in the electrical cord retention bracket should fit over the cord Do not pinch the cord in the bracket 3 Install the plastic cover Item 2 in the Accessories List as shown There is one screw located on the lower right flange of the cover and one screw under the elec trical connector access cover Once secure use enclosed screw Item 10 in the Accessories List to close the access door 4 Install the quick connect cover as shown in figure 4 Once in place secure using enclosed 8 x 3 4 screw located on the top flange of the quick connect cover Item 10 A All Covers must be in place to operate unit SHOCK HAZARD exists without electrical access cover Cover cannot be Installed without completing steps 8 1 through 8 4 properly STEP 9 Locate the condensate drain The connecting line has a built in condensate line hose that removes the moisture collected from the indoor module The hose must be located in an appropriate location for drainage Because the hose relies on gravity to drain it is important that the hose only points downw
10. oor unit with a single Phillips head screw Remove screw to release the bracket for installation NOTE Attach the wall bracket to the wall lt lt with at least two screws capable of securing at least 60 lbs Option 1 installation remove Option 2 installation remove full small knockout for power knockout for power cord and con cord only necting line Option 2 Window Installation Using Friedrich SimpleSilt 1 Be sure window sill is clean and free of dirt and debris With the window raised place bottom seal gasket trimmed to window width firmly against window sill adhesive side down Expand the SimpleSill 1 greater than the width of the win dow and install the securing pin Place one end of the SimpleSill into the window opening so it is against the corner of the window frame and sill Raise the other side of the SimpleSill 6 9 inches depending on window width above the window sill Next press the raised side down until the SimpleSill is lodged securely into position The SimpleSill end gaskets will conform to the window track shape 2 Reference Step 4 2 and pass the connecting line out the window and Insert It Into the connecting line form in the SimpleSilt 3 Install top seal gasket to the bottom of the window so it will seal against the top of the SimpleSIll Replace the pass through cover Insert securing pins Lower window frame against SimpleSill compressing gasket
11. s so locate them accordingly You cannot 25 ft add additional length if they are too far apart a l Placing the indoor unit A power It is recommended that you install the indoor module on an exterior wall within 6 feet of a properly rated outlet for the system you are Installing The BR1224W3A plugs 25 ft max into a 230V 15A outlet The system should be plugged into a single circuit outlet only Typically hanging the 12 minimum l i l l clearance indoor module above or adjacent to a window will aa provide a great location NOTE You should not drill through the window header part of the rough framing located directly above the window opening Placing the outdoor unit The outdoor module should be placed on a level surface with adequate clearance from items like shrubbery solid fencing or other air conditioning equipment that can impede airflow to the module The outdoor module must be at least 12 from the wall for proper airflow The mounting pad provided with the system will raise the module off of the ground 3 The fan should face away from the building SHOCK HAZARD DO NOT PLUG IN indoor unit until all installation work is completed Connect to a single dedicated circuit sized for the load DO NOT kink or bend refrigeration line set less than 3 radius A connecting line bending guide Is provided Line set is under high pressure DO NOT Puncture line set DO NOT Heat line set Always follow all local an
12. usly Press them again and the remote will unlock The unit ships with the temperature readout in degrees Fahrenheit To change to degrees Celsius press the MODE and W buttons simultaneously when the unit is off Press them again and the remote will return to Fahrenheit
Download Pdf Manuals
Related Search
Related Contents
Sigma MRX Series Operator's Manual MZE「」形取扱説明書 【PDF】 Quick User Guide Suzo nr: 177-0700 Enermax AeroOdio Hewlett Packard Enterprise IMC Standard Software Platform DEMANDE D`ADHESION A LA MAISON DE LA VIE ASSOCIATIVE よくわかる ライフスタイル バイク N Useries Perfect Enhance - B&H Photo Video Digital Cameras, Photography ペニングゲージゲージコントローラ PEG Copyright © All rights reserved.
Failed to retrieve file