Home

Franke Consumer Products Ventilation Hood FAD 367 W User's Manual

image

Contents

1. DIMENSIONS et PRINCIPALES PIECES Dimensions 10 3 16 11 13 16 2 9 10 4 15 16 7 T 11 16 B Max 39 7 16 3 21 5 16 Min 26 7 16 ro 35 7 16 T Y 2 5 16 N o Composantes 15 Ref Qt Pi ces du produit C 090 q 1 1 Corps de la hotte quip de commandes lumi re groupe ventilateur filtres posu DET 2 1 Chemin e t lescopique form e de LES 2 2 1 1 Chemin e sup rieure pu e 22 1 Chemin e inf rieure 15 _ Ez 10 1 Clapetanti reflux X 141 2 Rallonges de raccord de sortie d air 24 o 1 15 1 Raccord de sortie d air 3 Ires Ref Qt Pi ces servant l installation vu 72 1 2 Brides de montage de la chemin e sup rieure m 7 3 1 Bride de raccord de sortie d air a 11 Chevilles si fournies 6 12a 6 Vis 3 16 x 1 3 4 12c 6 Vis 1 8 x 3 8 Qt Documentation 1 Manuel d instructions INSTALLATION Percage de la paroi et fixation des brides A Tracer sur la paroi une ligne verticale allant jusqu au plafond ou la limite sup rieure au centre de la zone pr vue pour l installation de la hotte Tracer une ligne horizontale 24 pop au dessus du plan de cuisson Poser comme indiqu une bride 7 2 1 sur la paroi 1 16 pop du plafond ou de la limite su p rieure en alignant son
2. tiquette d avertissement pro minent interdisant le r tablis sement de l alimentation IMPORTANT Pour une ventilation de type g n ral seulement Ne pas utiliser cet appareil pour l vacuation de mati res ou vapeurs explosives AVERTISSEMENT POUR MINIMISER LES RISQUES D INCENDIE CHOC LECTRI QUES OU BLESSURES OBSERVER CETTE REGLE l installation et le raccordement lectrique ne doivent tre effectu s que par un technicien s qualifi selon tous les codes municipaux Afin d obtenir un rendement maximal en ce qui a trait la combustion ainsi qu l vacuation des gaz par la conduite de chemin e et pour qu il n y ait pas de reflux des gaz de combus tion une bonne a ration est n cessaire pour tous les appareils combustion Suivez les conseils et mesures de s curit du fournisseur tels que ceux publi s par la National Fire Pro tection Association NFPA et l American Society for Heating Refrigeration and Air Condition Engineers ASHRAE ainsi que les codes municipaux Lors d op ration de d coupage et de percage dans un mur ou un plafond veiller ne pas endommager les c blages lectriques ou canalisations qui peuvent s y trouver Un conduit de ventilation doit toujours se terminer l ext rieur AVERTISSEMENT Une prise la terre est n cessaire pour cette hotte N UTILISEZ PAS un tuyau l eau froide pour la mise la terre s il est connect du plastique un joint non m tallique ou a
3. Cela fournira la structure et le soutien n cessaire au montage Branchements A 4 SORTIE D AIR VERSION ASPIRANTE P 1 En cas d installation en version aspirante brancher la hotte la M tuyauterie de sortie via un tube rigide de 6 po e Installer le clapet d air 10 Fixer le tube par des colliers appropri s Le mat riel n ces saire n est pas fourni SORTIE D AIR VERSION FILTRANTE Ins rer le raccord 15 dans le support 7 3 Ins rer lat ralement les rallonges de raccord 14 1 sur le raccord 15 S assurer que la sortie des rallonges de raccord 14 1 se trouve au niveau des ouvertures de la chemin e aussi bien en horizon tal qu en vertical Brancher le raccord 15 la sortie du corps de la hotte avec un tube rigide de 6 po pas fourni S assurer de la pr sence des filtres anti odeur au charbon actif Fr A BRANCHEMENT ELECTRIQUE e Retirer le couvercle du compartiment de filage l aide d un Filde masse tournevis Phillips m pe Passer le c ble d alimentation dans la pastille enfon able d Brancher le cable d alimentation sur la hotte le conducteur de mise la terre du c ble d alimentation la vis verte fournie Attacher le fil blanc du c ble d alimentation au fil blanc de la hotte avec une cosse connecteur de fils Atta cher le fil noir du c ble d alimentation au fil noir de la hotte avec une cosse connecteur de fils Replacer le couverc
4. Body complete with Controls Light Blower 2 Filters Suo 2 1 Telescopic Chimney comprising Er 24 1 Upper Section e 22 1 Lower Section wo A D Ea 10 1 Damper pa 141 2 Air Outlet Connection Extension LUE de 15 1 Air Outlet Connection S Ref Q ty Installation Components 72 1 2 Upper Chimney Section Fixing Brackets 22 7 3 1 Air Outlet Connection Suppot O 11 6 WallPlugs if supplied 12a 6 Screws 3 16 x 1 3 4 7 12c 6 Screws 1 8 x 3 8 Q ty Documentation 1 Instruction Manual INSTALLATION Wall drilling and bracket fixing I Wall marking Draw a vertical line on the supporting wall up to the ceiling or as high as practical at the center of the area in which the hood will be installed Draw a horizontal line at 24 above the hob Place bracket 7 2 1 on the wall as shown about 1 16 from the ceiling or upper limit aligning the center notch with the vertical reference line Mark the wall at the centers of the holes in the bracket Place bracket 7 2 1 on the wall as shown at X below the first bracket X height of the up per chimney section supplied aligning the center notch with the vertical line Mark the wall at the centers of the holes in the bracket Mark a reference point as indicated at 4 9 16 from the vertical reference line and 12 5 8 above the horizontal reference line Repeat this operation on the other side Drill 5 16 holes
5. a gas pipe DO NOT have a fuse in the neutral or grounding circuit A fuse in the neutral or ground ing circuit could result in electrical shock Check with a qualified electrician if you are in doubt as to whether the rangehood is prop erly grounded Failure to follow electrical requirements may result in a fire RECOMMENDATIONS AND SUGGESTIONS AThe Instructions for Use apply to several versions of this appliance Accordingly you may find descriptions of individual features that do not apply to your specific appliance INSTALLATION The manufacturer will not be held liable for any damages resulting from incor rect or improper installation Check that the main voltage corresponds to that indicated on the rating plate fixed to the inside of the hood The electrical supply must be properly and sufficiently grounded Connect the extractor to the exhaust flue through a pipe of minimum diameter 6 The route of the flue must be as short as possible Do notconnect the extractor hood to exhaust ducts carrying combustion fumes boilers fireplaces etc Ifthe extractor is used in conjunction with non electrical appliances e g gas buming appliances a sufficient degree of aeration must be guaranteed in the room in order to prevent the backflow of exhaust gas The kitchen must have an opening communicating directly with the open air in order to guarantee the entry of clean air USE The range hood has
6. centre encoche sur la ligne verticale de rep re Marquer les centres des trous rainur s de la bride Poser comme indiquer la bride 7 2 1 X pop sous la premi re bride X hauteur de la chemin e sup rieure en alignant son centre encoche sur la ligne verticale de rep re Marquer les centres des trous rainur s de la bride Marquer comme indiqu un point de r f rence 4 et 9 16 pop de la ligne verticale de re p re ainsi qu 12 et 5 8 pop au dessus de la ligne horizontale de rep re R p ter cette op ration sur le c t oppos Perce de 5 16 pop tous les points marqu s Ins rer les chevilles 11 dans les trous Fixer la bride inf rieure 7 2 1 en utilisant les 12a fournies Fixer ensemble la bride sup rieure 7 2 1 et le support 7 3 en utilisant les 2 vis 12a fournies Visser les 2 vis 12a fournies dans les trous de fixation du corps de la hotte en laissant un espace de 3 16 pop entre le mur et la t te de vis Montage du corps de la hotte Avant d accrocher le corps de la hotte serrer les deux vis Vr situ es sur les points d ancrage du corps de la hotte Accrocher le corps de la hotte solidement aux vis 12a pr vues cet effet Ajuster les vis Vr afin de placer le corps de la hotte niveau Note Le corps de la hotte devrait tre fixer au poteau mural Si n cessaire installer un support en bois derri re la paroi s che mi chemin entre deux poteaux muraux
7. spaces within walls or ceilings or into attics crawl spaces or garages Determine which venting method is best for your application Ductwork can extend either through the wall or the roof The length of the ductwork and the number of elbows should be kept to a minimum to provide efficient performance The size of the ductwork should be uni form Do not install two elbows together Use duct tape to seal all joints in the ductwork system Use caulking to seal exterior wall or floor opening around the cap Flexible ductwork is not recommended Flexible ductwork creates back pressure and air turbu lence that greatly reduces performance Make sure there is proper clearance within the wall or floor for exhaust duct before making cutouts Do not cut a joist or stud unless absolutely necessary If a joist or stud must be cut then a supporting frame must be constructed WARNING To Reduce The Risk Of Fire Use Only Metal Ductwork Venting system MUST terminate outside the home DO NOT terminate the ductwork in an attic or other enclosed space DO NOT use 4 laundry type wall caps Flexible type ductwork is NOT recommended DO NOT obstruct the flow of combustion and ventilation air Failure to follow venting requirements may result in a fire ELECTRICAL REQUIREMENTS A 120 volt 60 Hz AC only electrical supply is required on a separate 15 amp fused circuit A timedelay fuse or circuit breaker is recommended The fuse must b
8. une a ration suffisante de l espace Sila cuisine en est d pourvue pratiquez une ouverture qui communique avec l ext rieur pour garantir l infiltration de l air pur UNE SATIOM La hotte a t concue exclusivement pour un usage domestique dans le but d liminer les odeurs de la cuisine Ne jamais utiliser la hotte de mani re abusive Ne pas laisser les flammes libres forte intensit lorsque la hotte est en ser vice Toujours r gler les flammes de mani re viter toute sortie lat rale de ces derni res par rapport au fond des casseroles Contr ler les friteuses lors de l utilisation car l huile surchauff e pourrait s enflammer La hotte ne doit pas tre utilis e par des enfant ou des personnes ne pouvant pas en assurer une utilisation ad quate ENTRETIEN Avant de proc der a toute op ration d entretien retirer la hotte en la d bran chant ou en la mettant hors circuit Effectuer un entretien scrupuleux et en temps voulu des filtres Pour le nettoyage des surfaces de la hotte il suffit d utiliser un linge humide et un d tergent liquide neutre PROTECTEUR THERMIQUE Cette hotte est quip e d un protecteur thermique afin de pr venir le surchauf fage Sila hotte s teint en cours d utilisation appuyez sur le bouton en mar che arr t afin de remettre la hotte en position Arr t Attendez environ 90 minu tes puis appuyez de nouveau sur le bouton en marche arr t pour red marrer la hotte
9. 0 ainsi qu aux r glements locaux et les sp cifications de cet appareil On peut ob tenir ces informations aupr s de National Fire Protection Association Batterymarch Park Quincy Massachusetts 02269 Raccordez cet appareil directement au coupe circuit ou au disjoncteur par l interm diaire de c ble conducteurs de cuivre blindage m tallique flexible ou gaine non m tallique Un serre c ble de 1 po 12 7 mm homologation UL ou CSA doit tre install chaque extr mit du c ble d alimentation sur la hotte et sur le bo tier de distribution Faites un trou de 1 14 po dans le mur S il s agit d un mur en bois sablez bien le trou Tandis qu un trou dans le m tal demande un oeillet passe fil AVERTISSEMENT POUR R DUIRE LE RISQUE D INCENDIE OU DE CHOC LECTRI QUE ne pas utiliser ce ventilateur en conjonction avec un dispositif de r glage de vitesse semi conducteurs AVERTISSEMENT POUR MINIMISER LES RISQUES D INCENDIE CHOC LECTRI QUES OU BLESSURES OBSERVER CETTE REGLE suivez strictement les recommandations du fabricant en cas de n cessit veuillez le contacter Avant d entreprendre un travail d entretien ou de nettoyage interrompre l alimentation de la hotte au niveau du tableau de disjoncteur et verrouiller le tableau de disjoncteur pour emp cher tout r tablissement accidentel de l alimentation du circuit Lorsqu il n est pas possible de ver rouiller le tableau de disjoncteur une
10. FRANKE ADMIRAL 36 Range Hood Hotte Installation Instructions Use and Care Guide Instructions d installation Mode d emploi et d entretien FAD 367 W INDEX WARNINGS AND REQUIREMENTS RECOMMENDATIONS AND SUGGESTIONS 6 DIMENSIONS and MAIN PARTS e 8 TO titled ve eite A 11 CARE 12 READ AND SAVE THESE INSTRUCTIONS The Installer must leave these instructions with the homeowner The homeowner must keep these instructions for future reference and for local electrical inspec tors use READ THESE INSTRUCTIONS BEFORE YOU START INSTALLING THIS RANGEHOOD WARNING TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE Never leave surface units unattended at high settings Boilovers cause smoking and greasy spillovers that may ignite Heat oils slowly on low or medium setting Always turn hood ON when cooking at high heat or when flamb ing food i e Crepes Suzette Cherries Jubilee Peppercorn Beef Flamb Clean ventilating fans frequently Grease should not be allowed to accumulate on fan or filter Use proper pan size Always use cookware appropriate for the size of the surface element WARNING TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT OF A RANGE TOP GREASE FIRE OBSERVE THE FOLLOWING SMOTHER FLAMES with a close fitting
11. MUR OU LE PLANCHER PROXIMIT DE LA HOTTE DOIT ETRE SCELLE Gardez 24 po de hauteur entre le bas de la hotte et la surface de cuisson Consultez la fiche tech nique avant de d couper les armoires INSTALLATION DANS UNE MAISON MOBILE L installation de cette hotte doit tre conforme aux r glements de Manufactured Home Construc tion and Safety Standards Titre 24 CFR Section 3280 anciennement Federal Standard for Mo bile Home Construction and Safety Titre 24 HUD Section 280 Le branchement lectrique s effectue avec un raccordement 4 fils Consultez la Fiche Technique lectrique EXIGENCES DE VENTILATION VACUATION ATTENTION Afin de r duire le risque d incendie et pour bien vacuer l air assurez vous de faire chap per l air des conduits l ext rieur Ne jamais vacuer l air vers des espaces comportant des murs ou des plafonds ou dans le grenier la galerie ou le garage D terminer la m thode d vacuation de l air la plus appropri e pour l application La sortie d evacuation soit par le mur soit par le toit Utilisez une longueur de tuyauterie minimale incluant le moins de coudes possible pour une plus grande efficacit Le calibre de la tuyauterie doit tre uni forme N installez jamais 2 coudes ensembles Scellez bien tous les joints avec un ruban adh sif m tallique l int rieur et scellez bien le clapet ext rieur en utilisant du calfeutrage L utilisation d un tuyau d vacuation flexible n est pas
12. OMMANDE EN OPTION Cet appareil peut tre contr l l aide d un t l commande ali ment e par une pile alcaline carbone zinc de type AAA 1 5 volt Filtres graisse m talliques Ils sont lavables au lave vaisselle et doivent tre lav s chaque fois que le symbole FF s affiche ou environ tous les 2 mois ou plus souvent m me en cas d utilisation particuli rement inten sive R tablissement du signal d alarme teint les lumi res et le moteur d aspiration au cas la fonc tion 24h est active il convient de la d sactiver Appuyer sur la touche E jusqu ce que l afficheur s teigne Nettoyage des filtres Retirer les filtres un un en les tenant d une main et en tirant simultan ment vers le bas sur la poign e avec l autre main Laver les filtres en vitant de les plier et les faire s cher avant de les remonter Remonter les filtres en faisant attention de tenir la poign e vers la partie externe Filtre anti odeur au charbon actif version filtrante Il ne peut tre ni lav ni r cup r Il faut le changer quand EF s affiche ou au moins tous les 4 mois D clenchement du signal d alarme Pour les hottes de la version filtrante l alarme indiquant la saturation des filtres doit tre activ e au moment de l installation ou ult rieurement teindre les lumi res et le moteur d aspiration D brancher la hotte du r seau lectrique R tablir le branchement
13. ake sure that the handle is visible on the outside Charcoal filter ductless version This filter cannot be washed or regenerated It must be replaced when the EF appears on the display or at least once every 4 months Activation of the alarm signal In the recycling version hoods the filter saturation alarm must be activated during the instal lation or later Switch off the hood and the lights Disconnect the hood from the main voltage supply After restoring the connection press and hold B key When releasing the key two rotating rectangles appear on the display Within 3 seconds press the B key until a flashing confirmation appears on the dispaly 2flashes with EF charcoal filter saturation alarm ACTIVATED e flash with EF charcoal filter saturation alam DEACTIVATED REPLACING THE CHARCOAL FILTER Reset of the alarm signal Switch off the hood and the lighting If the 24h function has been activated this has to be deactivated Press the E key until the display is unlit Replacing of the filter Remove the metal grease filters Remove the saturated charcoal filter by releasing the fixing hooks Fit the new filter and fasten it in its correct position Put the metal grease filters in their seats Lighting LIGHT REPLACEMENT 20 W halogen light Remove the 2 screws fixing the Lighting support and pull it out of from the Hood Extract the lamp from the Support Replace with an
14. at all the center points marked Insert the wall plugs 11 in the holes Fix the lower bracket 7 2 1 using the 12a screws supplied Fix the upper bracket 7 2 1 and the air outlet connection support 7 3 together using the 2 screws 12a supplied Insert the two screws 12a supplied in the hood body fixing holes leaving a gap of 3 16 between the wall and the head of the screw Mounting the hood body Before attaching the hood body tighten the two screws Vr lo cated on the hood body mounting points Hook the hood body onto the screws 12a Fully tighten support screws 12a Adjust screws Vr to level the hood body Note The Hood body should be secured to wall studs If neces sary install a wood support behind the dry wall flush mounted between 2 studs This will provide the necessary structure and support for mounting Connections DUCTED VERSION AIR EXHAUST SYSTEM When installing the ducted version connect the hood to the chimney using a rigid 6 duct Install the damper 10 9 6 Fix the duct in position using sufficient pipe clamps not sup plied DUCTLESS VERSION AIR OUTLET 241 Put connection 15 into connection support 7 3 Insert the connection extension pieces laterally 14 1 in connec tion 15 Make sure that the outlet of the extension pieces 14 1 is hori zontally and vertically aligned with the chimney outlets Connect the air outlet connection 15 to the hood body outlet u
15. been designed exclusively for domestic use to eliminate kitchen odors Never use the hood for purposes other than for which it has ben designed Neverleave high naked flames under the hood when itis in operation Adjust the flame intensity to direct it onto the bottom of the pan only making sure that it does not engulf the sides Deep fat fryers must be continuously monitored during use overheated oil can burst into flames The hood should not be used by children or persons not instructed in its cor rect use CARE Switch off or unplug the appliance from the main supply before carrying out any maintenance work Clean and or replace the Filters after the specified time period Clean the hood using a damp cloth and a neutral liquid detergent THERMAL PROTECTOR The range hood is equipped with a thermal protector to avoid overheating condi tions If the range hood shuts off in use press the on off button to return off range hood Wait approximately 90 minutes then press the on off button to restart the range hood DIMENSIONS and MAIN PARTS Dimensions 10 3 16 1 13 16 5 Du 2 9 16 4 15 16 I 7 o 3 2 I X c z D N m N N 2 L 35 7 16 20 3 16 2 5 16 Components 15 Ref Q ty Product Components C q 1 1 Hood
16. cates the selected speed latest selected speed B Decreases the vent speed C Increases the vent speed D By pressing this key it is possible to activate HI appears The spot down on the right side the intensive speed from any previously se flashes once a second lected speed The intensive speed can be acti vated even when the motor is OFF This speed has been timed at 10 minutes After that time the system activates automatically the latest selected speed This function is recommended for cooking condition where vapors and odors need to be eliminated immediately and quickly E By pressing this key it is possible to set up the Indicates the 24 function The spot down on motor to a suction speed at 60 CFM lasting 10 the right side flashes and the motor is on minutes every hour After this the motor D oe Once the process is finished the previous indi switches off automatically When the filter saturation is going on it is pos cation disappears e 8 8 num POS FF Indicates that the metal grease filters sible to reset the alarm by pressing this key for saturation alarm has been triggered and about 3 seconds The indication is visible only the filters need to be washed The alarm when the motor is off is triggered after 100 working hours EF Indicates that the charcoal filter satura tion alarm has been triggered and the fil ter has to be replaced the metal grease filters must also be washed The charcoal fi
17. d liminer vapeurs et odeurs rapi dement et imm diatement E Active le moteur une vitesse permettant une Affiche 24 function Le point en bas droite aspiration de 60 CFM pendant 10 minutes tou clignote quand le moteur fonctionne tes les heures puis le moteur s arr te HE y j En fin de proc dure le signal affich pr c Quand l alarme filtres est d clench e appuyer MM h dus 4 demment s teint pure cette touche pen SERRA es FF indique qu il faut laver les filtres pour remettre l alarme l tat initial Ces in graisse m talliques L alarme se d clen dications sont visibles uniquement quand le che apr s 100 heures de fonctionnement moteur est teint effectif de la hotte EF Indique qu il faut remplacer les filtres au charbon actif et laver les filtres graisse m talliques L alarme se d clenche apr s 200 heures de fonctionnement effectif de la hotte Active l arr t automatiquement retard de 30 Affiche la vitesse de service et le temps restant minutes Utile pour achever d liminer toute avant l arr t de la hotte Le point en bas odeur r siduelle S active depuis toutes les droite clignote indiquant tour tour la vitesse positions et se d sactive en appuyant sur la se aan et le temps restant touche ou en teignant le moteur G Allume et teint la lumi re H Allume et teint la lumi re intensit r duite SOIN ET ENTRETIEN TELEC
18. e sized per local codes in ac cordance with the electrical rating of this unit as specified on the serial rating plate located inside the unit near the field wiring compartment THIS UNIT MUST BE CONNECTED WITH COP PER WIRE ONLY Wire sizes must conform to the requirements of the National Electrical Code ANSI NFPA 70 latest edition and all local codes and ordinances Wire size and connec tions must conform with the rating of the appliance Copies of the standard listed above may be obtained from National Fire Protection Association Batterymarch Park Quincy Massachusetts 02269 This appliance should be connected directly to the fused disconnect or circuit breaker through flexible armored or nonmetallic sheathed copper cable Allow some slack in the cable so the ap pliance can be moved if servicing is ever necessary A UL Listed 1 2 conduit connector must be provided at each end of the power supply cable at the appliance and at the junction box When making the electrical connection cut a 1 1 4 hole in the wall A hole cut through wood must be sanded until smooth A hole through metal must have a grommet WARNING TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK do not use this fan with any solid state speed control device WARNING TO REDUCE THE RISK OF FIRE ELECTRICAL SHOCK OR INJURY TO PERSONS OBSERVE THE FOLLOWING Use this unit only in the manner intended by the manufac turer If you have any questions contact the man
19. eef Flamb Nettoyer fr quemment les ventilateurs d extraction Veiller ne pas laisser de la graisse s accumuler sur les surfaces du ventilateur ou des filtres Utiliser toujours un ustensile de taille appropri e AVERTISSEMENT POUR R DUIRE LE RISQUE DE DOMMAGES CORPORELS APRES LE D CLENCHEMENT D UN FEU DE GRAISSE SUR LA CUISINIERE APPLIQUER LES RE COMMANDATIONS SUIVANTES Blessures en cas de feu suivre les recommandations suivantes TOUFFEZ LE FEU AVEC UN COUVERCLE M TALLIQUE ET FERMEZ LE BR LEUR FAITES ATTENTION DE NE PAS VOUS BR LER SI LE FEU NE S ETEINT PAS IMM DIATEMENT quit tez les lieux et appelez les pompiers ne touchez jamais une casserole en flammes VOUS POURRIEZ SUBIR DES BLESSURES N UTILISEZ JAMAIS DE L EAU OU UN TORCHON MOUILL POUR TEINDRE LE FEU CE QUI POURRAIT CAUSER UNE EXPLOSION DE VAPEUR vapeur br lante Utiliser un extincteur SEULEMENT si 1 Il s agit d un extincteur de classe ABC dont on connait le fonctionnement 2 Il s agit d un petit feu encore limit l endroit ot il s est d clar 3 Les pom piers ont t contact s 4 Il est possible de garder le dos orient vers une sortie pendant l op ration de lutte contre le feu N utilisez un extincteur que si 1 Vous avez sous la main un mod le ABC et vous comment l utiliser correctement 2 Le feu est faible et peu r pandu 3 Les pompiers sont d j pr venus 4 Vous conservez une sortie derri re vous TOUTE OUVERTURE DANS LE
20. le Able d alimentation nergie Montage de la chemin e Chemin e sup rieure largir l g rement les deux bords lat raux et les accrocher der ri res les brides 7 2 1 refermer jusqu la but e Fixer lat ralement aux brides l aide des 4 vis 12c fournies S assurer que la sortie des rallonges de raccord se trouve au niveau des bouches de la chemin e Chemin e inf rieure e largir l g rement les deux bords lat raux de la chemin e et les accrocher entre la chemin e sup rieure et la paroi refermer jusqu la but e Fixer lat ralement la partie inf rieure au corps de la hotte l aide des 2 vis 12c fournies UTILISATION Jol 7 G e an ES m Bo C Tableaux des commandes Touche Fonction Afficheur A Allume et teint le moteur de ventilation la Affiche la vitesse s lectionn e derni re vitesse utilis e B Diminue la vitesse de ventilation C Augmente la vitesse de ventilation D Active la vitesse intensive partir de n importe Affiche HI et le point en bas droite clignote quelle vitesse m me du moteur arr t Cette une fois par seconde vitesse est programm e pour durer 10 minutes apr s quoi le syst me retourne la vitesse r gl e au pr alable Sert faire face une quan tit maximale de fum e de cuisson lorsqu il est n cessaire
21. lid cookie sheet or metal tray then turn off the burner BE CAREFUL TO PREVENT BURNS If the flames do not go out immediately EVACUATE AND CALL THE FIRE DEPARTMENT NEVER PICK UP A FLAMING PAN You may be burned DO NOT USE WATER including wet dishcloths or towels a violent steam explosion will result Use an extinguisher ONLY if 1 You know you have a Class ABC extinguisher and you already know how to operate it 2 The fire is small and contained in the area where it started 3 The fire department is being called 4 You can fight the fire with your back to an exit ALL WALL AND FLOOR OPENINGS WHERE THE RANGEHOOD IS INSTALLED MUST BE SEALED This rangehood requires at least 24 of clearance between the bottom of the rangehood and the cooking surface or countertop This minimum clearance may be higher depending on local build ing code Consult the cooktop or range installation instructions given by the manufacturer before making any cutouts MOBILE HOME INSTALLATION The installation of this rangehood must conform to the Manufactured Home Construction and Safety Standards Title 24 CFR Part 3280 formerly Federal Standard for Mobile Home Construction and Safety Title 24 HUD Part 280 Four wire power supply must be used and the appliance wiring must be revised See Elec trical Requirements VENTING REQUIREMENTS CAUTION To reduce risk of fire and to properly exhaust air be sure to duct air outside Do not vent ex haust air into
22. lter is triggered after 200 working hours F By pressing this key it is possible to set the Indicates both the selected speed of the hood delayed shutdown of the appliance to 30 min and the time left before the hood shutdown utes This function is suitable for a complete The spot down on the right side flashes alter elimination of the residual odors It can be ac y M As nately displaying the speed and shutdown time tivated at any position and it is deactivated by pressing the key again or by switching off the motor Turns light on and off Turns light on and off at reduced intensity CARE REMOTE CONTROL OPTIONAL This range hood can be controlled by a multi function remote control available through your local Franke Dealer Metal grease filters Filters can be washed in the dishwasher They need to be washed when FF sign appears on the display or in any case every 2 months or even more frequently in case of particularly intensive use of the hood Alarm reset Switch off the hood and the lights If the 24h function has been activated this has to be deactivated Press the E key till the display is unlit Cleaning the filters Remove the filters one at a time holding them up with one hand and pulling the handle downwards with the other hand at the same time Wash the filters taking care not to bend them Allow them to dry before refitting When refitting the filters m
23. other of the same type making sure that the two pins are properly inserted in the lamp holder socket holes Replace the Support fixing it in place with the two screws re moved as above TABLE DES MATIERES AVERTISSEMENT ET CONDITIONS N ECESSAIRES nus 15 CONSEILS ET SUGGESTIONS inmi 18 DIMENSIONS et PRINCIPALES PI CES nanas 19 INSTALLATION ans erro ad ERRAT DR Din EE Ten 20 UTILISATION ka a a CORREO BR PAR e PA ORE 23 credite inerti dee etd 24 LIRE ET CONSERVER CES INSTRUCTIONS L installateur doit laisser ces instructions au propri taire Le propri taire doit conserver ces instructions en vue d une utilisation subs quente et pour le b n fice de en lectricit LISEZ BIEN CETTE FICHE AVANT D UTILISER LA HOTTE AVERTISSEMENT POUR MINIMISER LE RISQUE D UN FEU DE GRAISSE SUR LA CUISI NIERE Ne jamais laisser un l ment de la surface fonctionner sans surveillance la puissance de chauffage maximale un renversement d bordement de mati re graisseuse pourrait provoquer un incendie ou causer de la fum e Utiliser toujours une puissance de chauffage moyenne ou basse pour faire chauffer de l huile Veiller toujours faire fonctionner le ventilateur de la hotte lors d une cuisson avec une puissance de chauf fage lev e ou lors de la cuisson d un mets flamber i e Cr pes Suzette Cherries Jubilee Peppercorn B
24. puis presser et maintenir la touche B Rel cher la touche et deux rectangles en rotation apparaissent sur l afficheur Dans les 3 secondes qui suivent appuyer sur la touche B jusqu ce que s affichent EF clignotant deux fois Alarme saturation filtre charbon actif ACTIV E EF clignotant une fois Alarme saturation filtre charbon actif D SACTIV E REMPLACEMENT DU FILTRE ANTI ODEUR AU CHARBON ACTIF R tablissement du signal d alarme teint les lumi res et le moteur d aspiration au cas o la fonc tion 24h est active il convient de la d sactiver Appuyer sur la touche E jusqu ce que l afficheur s teigne Changement des filtres Retirer les filtres graisse m talliques Retirer le filtre anti odeur au charbon actif satur en agissant sur les crochets qui le tiennent en place Mettre le nouveau filtre en l accrochant bien en place Remonter les filtres graisse m talliques clairage REMPLACEMENT DES AMPOULES Lampe halogene de 20 W Retirer les 2 vis qui fixent le support clairage et retirer ce der nier de la hotte Extraire l ampoule du support Remplacer par une nouvelle ampoule poss dant les m mes ca ract ristiques en veillant ce que les deux fiches soient correctement ins r es dans le logement de la douille Remonter le support en le fixant l aide des deux vis pr c demment retir es FRANKE 436003936_01 070811
25. recommand e Les tuyaux flexibles cr ent une contre pression et de la turbulence ce qui r duit la puissance d vacuation Veillez ce que l espace pour le tuyau soit amplement suffisant ainsi vous n aurez pas d cou per les supports de mur int rieur On ne doit couper une solive ou un poteau de colombage que lorsque cela est absolument n cessaire S il est n cessaire de couper une solive ou un poteau du colombage on doit construire une structure de support appropri e AVERTISSEMENT Afin de r duire le risque d incendie utilisez seulement des conduits en m tal Le syst me d vacuation DOIT se terminer l ext rieur N VACUEZ PAS le conduit dans un grenier ou dans tout autre espace ferm N UTILISEZ PAS un clapet de s cheuse 4 pouces ON D CONSEILLE l emploi de conduit d vacuation flexible N ENCOMBREZ PAS la circulation d air Le fait de ne pas respecter ces avertissements pourrait occasionner un incendie FICHE TECHNIQUE LECTRIQUE Le raccordement lectrique doit se faire avec un circuit s par de 15 amp res fusibles 120 V 60 Hz courant alternatif Nous recommandons un coupe circuit La taille du fusible doit se conformer aux codes municipaux suivant la sp cification lectrique sur la plaque int rieure CET APPAREIL NE DOIT TRE CONNECT QU EN UTILISANT DES FILS EN CUIVRE Le diam tre du fil devra aussi se conformer aux r glements du code national lectrique ANSI NFPA 7
26. sing a rigid 6 duct not supplied Ensure that the activated charcoal filters have been inserted ELECTRICAL CONNECTION Remove the cover from the Field Wiring Compartment with a phillips screwdriver Ground Feed the Power Supply Cable through the electrical knockout Connect the Power Supply Cable to the range hood cable At tach the Power Supply Cable grounding lead to the green screw provided Attach the White lead of the power supply to the White lead of the rangehood with a twist on type wire connec tor Attach the Black lead of the power supply to the Black lead of the rangehood with a twist on type wire connector Replace the cover Ground wire Power supply cable Chimney assembly Upper exhaust Chimney Slightly widen the two sides of the upper flue and hook them behind the brackets 7 2 1 making sure that they are well seated e Secure the sides to the brackets using the 4 screws 12 sup plied Make sure that the outlet of the extensions pieces is aligned with the chimney outlets Lower exhaust Chimney Slightly widen the two sides of the flue and hook them be tween the upper flue and the wall making sure that they are well seated Fix the lower part laterally to the hood body using the 2 screws 12c supplied E F o Control board Key Function Display A Switches the blower motor on and off at the Indi
27. ufacturer Before servicing or cleaning unit switch power off at service panel and lock the service discon necting means to prevent power from being switched on accidentally When the service discon necting means cannot be locked securely fasten a prominent warning device such as a tag to the service panel CAUTION For General Ventilating Use Only Do Not Use To Exhaust Hazardous or Explosive Materials and Vapors WARNING TO REDUCE THE RISK OF FIRE ELECTRICAL SHOCK OR INJURY TO PERSONS OBSERVE THE FOLLOWING Installation Work And Electrical Wiring Must Be Done By Qualified Person s In Accordance With All Applicable Codes And Standards In cluding Fire Rated Construction Sufficient air is needed for proper combustion and exhausting of gases through the flue chimney of fuel burning equipment to prevent backdrafting Follow the heating equipment manufacturer s guideline and safety standards such as those published by the National Fire Protection Association NFPA and the American Society for Heating Refrigeration and Air Conditioning Engineers ASHRAE and the local code authorities When cutting or drilling into wall or ceiling do not damage electrical wiring and other hidden utilities Ducted fans must always be vented to the outdoors Electrical ground is required on this rangehood If cold water pipe is interrupted by plastic nonmetallic gaskets or other materials DO NOT use for grounding DO NOT ground to
28. utre mat riel N EFFECTUEZ PAS la mise la terre sur la conduite de gaz NE PAS INSTALLER un fusible dans le conducteur neutre ou le conducteur de liaison la terre V rifiez avec un lectricien qualifi que la hotte est bien mise la terre Le fait de ne pas respecter ces avertissements pourrait occasionner un incendie CONSEILS ET SUGGESTIONS A Les instructions d utilisation s applique plusieurs versions de ce type d appareil En cons quence il est possible que vous trouviez des descriptions de caract ristiques ne s appliquant pas votre appareil INSTALLATION Le fabricant d cline toute responsabilit en cas de dommage d une installa tion inad quate ou non conforme aux regles de l art V rifiez que la tension du secteur correspond la valeur qui figure sur la pla quette appos e l int rieur de la hotte L alimentation lectrique doit tre ad quatement et suffisamment mise la terre Connectez la hotte la sortie de l air aspir l aide d une tuyauterie d un dia Sup rieur a 6 po Le parcours de la tuyauterie doit tre le plus court possible Evitez de connecter la hotte des conduites d vacuation de fum es issues d une combustion tel que une chaudi re une chemin e etc Si vous utilisez des appareils qui ne fonctionnent pas a l lectricit dans la pi amp ce ou est install e la hotte par exemple des appareils fonctionnant au gaz vous devez pr voir

Download Pdf Manuals

image

Related Search

Related Contents

Version 1 D  1 convenio de utilización de medios electrónicos para las    取扱説明書 取扱説明書  取扱説明書:パージリング  Valhall Operators Manual  3 - Birota  

Copyright © All rights reserved.
Failed to retrieve file