1. CN 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 PART NO 120928 43 120928 06 120928 05 120928 07 120927 08 120928 26 120928 27 120928 42 120927 12 120928 13 120927 14 120927 15 120927 20 120927 21 120926 32 120927 24 120928 03 120928 02 120928 25 120928 01 122660 01 120927 16 120928 40 120928 44 120928 45 1120928 46 PARTS DESCRIPTION Blower Rear Glass Screen Log Set Flame Effect Mirror Handles Main Control Board and Standoffs 6 Transformer E Heater Settings Control Board LED Drum Assembly Motor Drum LED Ember Strip Remote Control Remote Control Sensor Magnetic Catch ON OFF Switch Front Glass Control Panel Door Black Top Black Front Trim Nailing Flange Bracket Back Light Strip Grate Flame Effect Mirror Bracket Front Glass Bracket Heater Blower Bracket i AAA PARTS AVAILABLE NOT SHOWN sum 120928 dE 120928 18 120928 19 120927 23 Wire Flame Effect Wire Ember Bed Wire Backlight Thermocouple www fmiproducts com QTY NIN BS a gt H H G H H H H 0 H S gt E NOTES www fmiproducts com 122638 01E NOTES
2. 122638 01E www fmiproducts com WARRANTY KEEP THIS WARRANTY Model located on product or identification tag Serial No located on product or identification tag Date Purchased Keep receipt for warranty verification FMI PRODUCTS LLC LIMITED WARRANTIES New Products Standard Warranty FMI PRODUCTS LLC warrants this new product and any parts thereof to be free from defects in material and workmanship for a period of two 2 years from the date of first purchase from an authorized dealer provided the product has been installed maintained and operated in accordance with FMI PRODUCTS LLC s wamings and instructions For products purchased for commercial industrial or rental usage this warranty is limited to 90 days from the date of first purchase Factory Reconditioned Products Limited Warranty FMI PRODUCTS LLC warrants factory reconditioned products and any parts thereof to be free from defects in material and workmanship for 30 days from the date of first purchase from an authorized dealer provided the product has been installed maintained and operated in accordance with FMI PRODUCTS LLC s wamings and instructions Terms Common to All Warranties The following terms apply to all of the above warranties Always specify model number and serial number when contacting the manufacturer To make a claim under this warranty the bill of sale or other proof of purchase must be presented This warranty is extended only to the original
3. A WARNING Due to high tem peratures this heater should be located out of traffic Keep combustible materials such as furniture pillows bedding papers clothes and curtains at least 3 feet 0 9 m from the front of the heater NOTICE Minimum and maximum clearances mustbe maintained at alltimes Illustrations throughout these instructions reflect typical installations and are for design purposes only Actual installa tions may vary slightly due to individual preferences A WARNING Never locate this heater where it may fall into a bath tub or other water container AL WARNING To prevent contact with sagging or loose insulation the heater must not beinstalled against vapor barrier orexposed insulation Localized overheating could occur and a fire could result 4 www fmiproducts com 122638 01E LOCATING FIREPLACE Continued Figure 3 illustrates a variety of ways the heater CAUTION Donotexposethe may be located in a room The heater may heater to the elements such as be installed directly on the floor or raised on rain etc a hearth Corner Mantel CAUTION Weargloves and Installation safety glasses for protection during installation and main Framed tenance Into Wall Wall Mantel Existing This electric fireplace can be installed in a Installation Fireplace mantel framed into a wall or installed into an
4. Emi FMI PRODUCTS LLC ELECTRIC FIREPLACE INSERT 32 MODEL ES401 SAFETY INFORMATION AND INSTALLATION MANUAL SP C US Patent No 7 219 456 B1 Read these instructions completely before beginning installation Failure to follow them could cause a heater malfunction resulting in serious injury and or property damage A WARNING All electric heaters have hot and arcing or sparking parts inside Do not use it in areas where gasoline paint or flammable liquids are or are stored This fireplace meets the construction and safety stan dards of H U D for application in manufactured homes when installed according to these instructions INSTALLER Leave this manual with the appliance CONSUMER Retain this manual for future reference For more information visit www fmiproducts com TABLE OF CONTENTS ceo ette t eT Ld in A CELO Listing Approvals gt deca Product Dimensions Product Identification Unpacking and Testing Locating Fireplace Installation Finishing PEERS Cleaning and Maintenance Technical SOMOS corria Replacement Troubleshooting Wiring Diagram Accessories SAFETY WARNING Improper installa tion adjustment alteration ser vice or main
5. and top panel Backlight LED Strip Standoffs Figure 17 Replacing Backlight LED Strip 122638 01E CLEANING AND MAINTENANCE Continued REPLACING SETTINGS CONTROL BOARD 1 Follow steps 1 through 3 under Replacing Heater Blower page 9 2 Disconnect wires from main control board 3 Remove screws from bracket to remove settings control board 4 Place new settings control board into posi tion making sure each control is aligned with slot in panel Install using screws from step 3 DO NOT overtighten This will damage control board 5 Reconnect wires to main control board see Wiring Diagram page 14 6 Replace glass with brackets and top panel 7 Replace trim Figure 18 Replacing Settings Control Board REPLACING FLAME GENERATION LED 1 Follow steps 1 through 4 under Cleaning Firebox page 8 2 Remove screws from each side of log that secure log to base and remove log see Figure 11 page 9 3 Remove screws from sides and back of bottom panel of firebox 4 Gently lay unit on its back 122638 01E 5 There are several wires attached to bot tom panel Carefully remove panel 6 Disconnect wires from motor and LED drum assembly 7 Remove screws from bottom panel to remove assembly 8 If motor on assembly fails loosen clamps see Figure 19 Remove screws from motor Hold universal joint while removing motor and discard 9 Install new motor Slide motor shaft into u
6. 1 2 Follow steps 1 through 3 under Replacing Heater Blower page 9 Disconnect transformer wires from control board Remove screws and nuts from firebox surround to remove transformer see Figure 15 Remove and discard transformer Place new transformer against inside of firebox surround and replace screws and nuts removed in step 3 Reconnect transformer wires to control board see Wiring Diagram page 14 Replace glass with brackets and top panel Replace trim Transformer Figure 15 Removing Transformer REPLACING MAIN CONTROL BOARD 1 2 3 Follow steps 1 through 3 under Replacing Heater Blower page 9 Disconnect wires to main control board Squeeze top of standoffs to remove main control board and discard www fmiproducts com 4 Gently push new control board onto standoffs to install Reconnect wires to main control board see Wiring Diagram page 14 Replace glass with brackets and top panel Replace trim Main Control Board bud f Transformer Figure 16 Control Board REPLACING BACKLIGHT LED STRIP 1 Follow steps 1 and 3 under Replacing Heater Blower page 9 Disconnect wires from main control board Squeeze top of standoffs to remove back light LED strip and discard Place new backlight LED strip onto stand offs and push gently Connect wires to main control board see Wiring Diagram page 14 Replace glass with brackets
7. and hearth area A WARNING If the informa 2 Seal all drafts vents or ash clean outs tion in these instructions is with fiberglass insulation Seal flue Once not followed exactly a fire or sealed close damper to stop debris from explosion may result causing falling onto unit 3 If existing fire box is susceptible to mois property damage personal in ture cap top of chimney flue to prevent jury or death infiltration of water 122638 01E www fmiproducts com 5 A WARNING RISK OF FIRE To prevent a possible fire do not block air intake or exhaust in any manner Do not use on soft surfaces where openings may become blocked Ad WARNING RISK OF FIRE Do not blow or place insulation against the firebox e INSTALLATION Continued Note It is strongly advised that you hire a qualified professional to undertake this step in order to prevent personal injury Once flue is capped chimney is no longer suitable for wood burning Note Do not install this unit into a fireplace that is prone to dampness the area of installation must be dry Plan the power supply Unit does not come with a power cord Unit must be hard wired to either a 120 60 or 240 60 volt supply 4 WARNING The solid fuel gas fireplace has been converted for use with an electric insert and cannot be used for original fuels unless all original parts have been replaced and the fireplace has been reapproved b
8. existing fireplace If installing into a mantel follow mantel s assembly instructions Figure 3 Heater Locations INSTALLATION AX WARNING RISK OF FIRE Do not store or use gasoline or The power cord must not be other flammable vapors in the vi pinched or against a sharp edge cinity of this or any other heater Secure cord to avoid tripping or INSTALLING FIREPLACE snaggingtoreducethe riskoffire Select a suitable location that is not suscep electric shock or personal injury tible to moisture and is a safe distance from Do not run cord under carpeting drapes furniture and high traffic areas Donotcovercord with throw rugs Note Follow all national and local electrical E codes This insert can be installed into either runners or the like Arrange cord an existing fireplace or as new construction away from traffic areas and where biis i renovation it will not be tripped over Installing in Mantel 1 Assemble mantel according to mantel instructions 2 Locate mantel near a wall or corner depending on mantel type close to a power source You may have to alter base boards to fit mantel flush against wall Connect fireplace to power source Insert fireplace into front of mantel Be careful not to scratch finish on base Fireplace will fit flush against front of mantel 4 Push mantel with fireplace into final location Existing Fireplace Installation 1 Thoroughly clean out existing fireplace
9. the date of first purchase FMI PRODUCTS LLC makes no other warranties regarding this product FMI PRODUCTS LLC s liability is limited to the purchase price of the product and FMI PRODUCTS LLC shall not be liable for any other damages whatsoever under any circumstances including indirect incidental or consequential damages Some states do not allow limitations on how long an implied warranty lasts or the exclusion or limitation of incidental or consequential damages so the above limitation or exclusion may not apply to you This warranty gives you specific legal rights and you may also have other rights which vary from state to state For information about this warranty contact IR FMI PRODUCTS LLC 2701 S Harbor Blvd Santa Ana CA 92704 1 866 328 4537 122638 01 www fmiproducts com Rev E P 09 09
10. to persons Avoid the use of an extension cord be cause the extension cord may overheat and cause a risk of fire However if you have to use an extension cord the cord should be No 14 AWG minimum size and rated not less than 1875 WATTS Always use ground fault protection where required by electrical codes 15 16 17 18 Always disconnect power before perform ing any cleaning maintenance or reloca tion of heater To prevent a possible fire do not burn wood or other materials in this heater To prevent electric shock or fire always use a certified electrician should new circuits or outlets be required When transporting or storing heater keep in a dry place Control panel door gets hot during heater operation Open door by pressing on right corner A spring magnet will disengage Pull door down to open 19 20 21 22 LISTING APPROVALS This heater has been tested in accordance with the CSA Standards for fixed and loca tion dedicated electric room heaters in the United States All components are UL CSA safety certified If you need assistance during installation please contact your local dealer or the FMI PRODUCTS LLC at 1 866 328 4537 Please have the distributor s model and serial numbers when you call Description 32 Fireplace Inserts Voltage 120 240 Watts 1500 3000 Amps 15 Amp 20 Amp Grounded Circuit Note This heater must be electrically wi
11. tom panel Using gloves gently remove glass panel by sliding it toward you There is a rubber bumper on each corner of glass Clean glass as instructed in step 1 or replace glass Using gloves reinstall glass by gently sliding smooth side toward fireplace front into brackets on either side that hold glass in place Replace log base Follow steps 11 and 14 under Replacing Flame Generation LED page 11 TECHNICAL SERVICE You may have further questions about installation operation or troubleshooting If so contact FMI PRODUCTS LLC at 1 866 328 4537 When calling please have your model and serial numbers of your heater ready You can also visit our web site at www fmiproducts com This information can be found on the fireplace s rating plate located behind the control panel door REPLACEMENT PARTS Note Use only original replacement parts This will protect your warranty coverage for parts replaced under warranty Contact authorized dealers of this product If they can t supply original replacement part s call FMI PRODUCTS LLC at 1 866 328 4537 www fmiproducts com When calling have ready your name your address model and serial numbers of your heater how heater was malfunctioning purchase date Usually we will ask you to return the part to the factory 122638 01E TROUBLESHOOTING A WARNING Turn off appliance and let cool before servicing Only a qualified service person should servi
12. 50 Depth Length 10 5 34 32 Note The height that a combustible mantel is fitted above the heater is a minimum of 1 above the front Li Figure 5 Framing Heater for New Construction Renovation www fmiproducts com 122638 01E INSTALLATION Continued Tools and building supplies required for installation Saw Square Pliers Gloves Hammer Level e Phillips screwdriver Surround Framing materials Electric drill bits Tape measure Wall finishing materials Caulking material CAUTION Provideadequate clearances around the air open ings and adequate accessibility clearances for servicing and proper operations Installing as Insert Once the site has been prepared your fire place insert can be installed 1 Make sure power switch is in the OFF position 2 Push fireplace insert so trim is against finished mantle or wall surface FINISHING AX WARNING Control panel door on this heater cannot in any way be covered as it may create a fire hazard Combustible Finishing Material Materials made of or surfaced with wood compressed paper plant fibers plastics or any material capable of igniting and burning whether flame proofed or not plastered or unplastered this includes drywall Noncombustible Finishing Material Ma terials which will not ignite and burn Such materials are those consisting entirely of steel iron brick tile concre
13. 6 C LOW will shut off when room reaches approximately 72 F 22 C Note Fan on heater will continue to run for 5 7 seconds after heater has been turned off Heater Ember Backlight Flame Control Control Control Control a E E E 0 Flame Backlight Heater Ember Power Lighted Power Switch Figure 6 Controls For Electric Fireplace www fmiproducts com OPERATION Continued 3 When using remote control aim remote at sensor located in center of unit just POWER FLAME EMBER BACKLIGHT HEATER Figure 7 Remote Control For Electric Fireplace above log set IMPORTANT This remote control must remain within 20 feet 6 m of fireplace to be effective 4 When power switch is turned off fireplace settings go back to default see Figure 8 HEATER Off Low Medium High FLAME Off Low Medium EMBER Off Low Medium BACKLIGHT Off Figure 8 Fireplace Settings Default Settings are Circled High CLEANING AND MAINTENANCE Ay WARNING Always discon nect power and allow the heater to cool before performing any cleaning maintenance or reloca tion of this heater Turn controls to OFF and remove plug from outlet or turn off circuit breaker to heater To service electric fireplace it may be neces sary to remove it from the mantel or enclosure in which it is installed Let unit cool completely before cleaning or servicing CLEANING FIREBOX 1 Ope
14. ce and repair heater OBSERVED PROBLEM POSSIBLE CAUSE REMEDY Fireplace turns off and will not turn on 1 Fireplace has overheated and safety devise has cause thermal switch to disconnect or home circuit breaker has opened 1 Reset switch by turning main power switch off and waiting 5 minutes then turn ing it back on or reset circuit breaker Flame is not moving 1 Loose wiring 2 Flame motor defective 1 Inspect wiring for loose connections 2 Call a qualified service techni cian to replace flame motor Flame is not visible 1 Wiring is loose 1 Disconnect from power source and inspect wiring for loose connections and repair or replace if necessary Log set and or ember is not glowing 1 Wiring is loose 1 Disconnect from power source and inspect wiring for loose connections and repair or replace if necessary Flame sputters flashes 1 Flame motor is defective 2 Flame generation contacts dirty obstructed 1 Callaqualified service techni cian to replace flame motor 2 Disconnect power Fol low steps to replace flame generation LED Clean contacts with dry cloth Remote control does not work 1 Low batteries 2 Not aiming control cor rectly 3 Defective remote control and or sensor 1 Replace AAA batteries in remote control 2 Aim control at sensor lo cated directly behind glass Screen in center of unit just above logs 3 Replace remote
15. control and or sensor Fireplace will not come on when switch is flipped to ON 1 Control failure 2 Breaker tripped 1 Call a qualified service tech nician to replace control 2 Reset breaker Heater does not provide heat when turned on 122638 01E 1 Thermal switch has been tripped 2 Circuit breaker has been tripped 3 Wiring is loose 4 Heater is defective 5 Thermostat cycled off www fmiproducts com 1 Turn unit off Turn off power to unit for 5 minutes Turn power and unit on 2 Turn off circuit breaker that supplies electricity to unit Wait 5 minutes then flip circuit breaker back on 3 Disconnect from power source and inspect wiring for loose connections and repair or replace if necessary Replace heater 5 Change to higher setting A 13 WIRING DIAGRAM peog 1 BUIDIAIaS Bnjdug synu pue uj SIJIM pasnun 19402 SNINYVM JeuuojsueJ E quiessy JOJO A Jung Remote Control Infrared Sensor v quiessv jueuie 3 LED Backlight Strip 0006 900 7064 Nid X18IN3SSV 1OH LNOO NOLLON 3 ANY 82d IWVOVIG TOH LNOO 39V Id3l3 919419373 9 PUE ZE yorig poy us pad Ke1c u3219 ues UMOJSg MOYA yoelg siding es OV xog uonounf xyoelg p
16. ember LED strip by squeezing top of standoffs and discard Connect new ember LED strip using exist ing standoffs Reconnect wire to LED strip Follow steps 3 through 5 under Replac ing Log REPLACING HEATER BLOWER 1 2 122638 01E Follow steps 1 and 4 of Cleaning Firebox page 8 Remove screws from around top panel of firebox see Figure 12 There are several wires attached to the top panel Carefully lift top panel Disconnect heater blower wires from main circuit board Remove screws holding heater blower to top panel see Figure 12 6 T 10 11 12 13 To Remove brackets from heater blower see Figure 13 Save brackets and screws To remove heater from blower remove 4 Screws 2 per side If replacing blower remove screws from brackets on blower see Figure 14 page 10 Install brackets to new blower Replace blower or heater Replace screws removed in step 7 Hold heater blower with brackets in place against top panel and replace screws removed in step 5 Reconnect wires to main circuit board see Wiring Diagram page 14 Replace glass with brackets and top panel Replace trim p Panel Screws Securing M Figure 12 Removing Top Panel and Heater Blower Figure 13 Removing Brackets from Heater Blower www fmiproducts com 9 CLEANING AND MAINTENANCE Continued Heater Figure 14 Removing Heater from Blower REPLACING TRANSFORMER
17. n control panel door by pressing on right side A spring magnet will push door forward Pull door down to open 2 Remove 2 screws holding front trim in place Pull gently to remove trim see Figure 9 There are magnets on the lower portion of trim see Figure 9 3 With gloves and safety glasses in place remove 4 screws from glass retainer brackets see Figure 9 4 Carefully remove front glass and brackets see Figure 10 5 Using a brush vacuum attachment gently clean compartment 6 After cleaning compartment replace front glass brackets and trim 8 www fmiproducts com Glass Bracket 1i Screws Screws SA Control Panel Door Magnets on 4 Back of Trim Trim Figure 9 Removing Trim Bracket Front Glass Figure 10 Removing Brackets and Front Glass 122638 01E CLEANING AND MAINTENANCE Continued REPLACING LOG 1 2 Ember LED n Strip with Standoffs Log Follow steps 1 through 4 of Cleaning Firebox page 8 Remove screws from each side of log that secure log to sides and remove log see Figure 11 Install new log using screws removed in step 2 Replace front glass and brackets Replace trim Screw Figure 11 Removing Log and Ember LED REPLACING EMBER STRIP 1 2 Follow steps 1 and 2 under Replacing Log Locate ember LED strip see Figure 11 Disconnect wire right side Remove
18. ng and unattended 5 Always unplug heater when not in use 6 Donotoperate any heater with a damaged cord or plug or if heater malfunctions or has been dropped or damaged in any way Return heater to authorized service facility for examination electrical or mechanical adjustment or repair 7 Do not use outdoors 8 This heater is not intended for use in bathrooms laundry areas and similar indoor locations Never locate heater where it may fall into a bathtub or other water container 9 Do not run cord under carpeting Do not cover cord with throw rugs runners or the like Arrange cord away from traffic area and where it will not be tripped over 10 To disconnect heater turn controls to the OFF before removing plug from outlet turn off power to unit 11 Do not insert or allow foreign objects to enter any ventilation or exhaust opening as this may cause an electric shock or fire or damage the heater 12 To prevent possible fire do not block air intakes in any manner Do not use on soft surfaces like a bed where openings may become blocked 13 Connect to properly grounded outlets only 122638 01E SAFETY Continued 14 A heater has hot and arcing or sparking parts inside Do not use it in areas where gasoline paint or flammable liquids or vapors are used or stored Use this heater only as described in this manual Any other use not recommended by the manufacturer may cause fire elec tric shock or injury
19. niversal joint and tighten clamps 10 Hold LED drum assembly in place on bottom panel and replace screws 11 Reattach wires to motor and LED drum Note LED drum wires are polarity sensi tive and must be connected correctly White wire plugs onto left terminal and red wire plugs onto right terminal Motor wires can be connected to either terminal 12 Replace fireplace bottom panel Set fire place upright and replace screws 13 Replace log glass and brackets 14 Reinstall fireplace and replace trim LED Drum 4 White Wire Assembly a Red Wire Motor Figure 19 Flame Generation LED Drum Assembly www fmiproducts com 11 1 CLEANING AND MAINTENANCE Continued CLEANING OR REPLACING BACK SCREEN GLASS The glass is cleaned in the factory during assembly During shipment installation handling etc glass surface may collect dust particles These can be removed by buffing lightly with a clean damp cloth water only Glass should be completely dried with a lint free cloth or paper towel In the event of glass breakage vacuum all remaining glass pieces with a shop vac DO NOT VACUUM WHILE PIECES ARE HOT Replace glass only with replacement part specifically for this heater Never substitute material Only fully tempered soda lime safety glass may be used on this heater 3 To access glass to clean or replace fol low steps 1 and 7 under Replacing Flame Generation LED page 11 Set aside bot
20. oy enig uses ep uses wold MOIISA ejdun PM SHUM OV ANZ xog uonounr yoelg pes enig e1c usa U91IMS 104904 18 oDBueJQ YO eld r18 SHUM LHM MY UB D VAO MOI 9A AMIA 9JON 122638 01E www fmiproducts com 14 ACCESSORIES Purchase these accessories from your local dealer If they can not supply these acces Sories either contact your nearest Parts Central or call FMI PRODUCTS LLC at 1 866 328 4537 for information You can also write to the address listed on the back 122638 01E page of this manual MANTELS W32TU 32 Wall Mantel Unfinished Traditional W32TO 32 Wall Mantel Oak Stain Traditional C32TU 32 Corner Mantel Unfinished Traditional C32TO 32 Corner Mantel Oak Stain Traditional W32CO 32 Wall Mantel Oak Stain Classic C32CO 32 Corner Mantel Oak Stain Classic W32DO 32 Wall Mantel Oak Stain Dentil W32GO 32 Wall Mantel Oak Stain Georgian C32GO 32 Corner Mantel Oak Stain Georgian www fmiproducts com 15 PARTS MODEL ES401 16 www fmiproducts com 122638 01E MODEL ES401 This list contains replaceable parts used in your fireplace When ordering parts follow the instructions listed under Replacement Parts on page 12 of this manual 122638 01E KEY NO 1
21. red and grounded in accordance with local codes or in the absence of local codes with National Electric Code ANSI NFPA 70 latest edition or the Cana dian Electric Code CSA C22 1 as appropriate PRODUCT DIMENSIONS 33 25 37 5 pum Figure 1 Heater Dimensions 122638 01E www fmiproducts com 3 PRODUCT IDENTIFICATION Control Panel Door Heat Vents Behind Door Front Glass Back Glass Remote Remote Hide Flame Control Handle Ember Control ON OFF Power Control Button Figure 2 Product Identification UNPACKING AND TESTING Carefully remove unit from box Prior to per manently installing unit test to make sure unit operates properly Unit does not come with a power cord installed Unit must be hard wired to either a 120 60 or 240 60 volt supply A CAUTION The unit s power supply cord must be connected to a properly grounded and pro tected 120 volt outlet Always use ground fault protection where required by the electrical code Ay WARNING Do not operate the unit if it is damaged or has malfunctioned If you suspect the unit is damaged return the unit to an authorized service facility for examination electri cal or mechanical adjustment or repair LOCATING FIREPLACE
22. retail purchaser when purchased from an authorized dealer and only when installed by a qualified installer in accordance with all local codes and instructions furnished with this product This warranty covers the cost of part s required to restore this product to proper operating condition and an allow ance for labor when provided by a FMI PRODUCTS LLC Authorized Service Center or a provider approved by FMI PRODUCTS LLC Warranty parts must be obtained through authorized dealers of this product and or FMI PRODUCTS LLC who will provide original factory replacement parts Failure to use original factory replacement parts voids this warranty Travel handling transportation diagnostic material labor and incidental costs associated with warranty repairs unless expressly covered by this warranty are not reimbursable under this warranty and are the responsibility of the owner Excluded from this warranty are products or parts that fail or become damaged due to misuse accidents improper installation lack of proper maintenance tampering or alteration s This is FMI PRODUCTS LLC s exclusive warranty and to the full extent allowed by law this express warranty excludes any and all other warranties express or implied written or verbal and limits the duration of any and all implied warranties including warranties of merchantability and fitness for a particular purpose to two 2 years on new products and 30 days on factory reconditioned products from
23. te slate glass or plasters or combinations thereof or have a fire rating of zero FINISHING CHECKLIST Power supply service must be completed prior to finishing to avoid reconstruction Grills and air openings cannot be covered in any circumstances Note The heater is a zero clearance fireplace and may be finished with combustible or non combustible finishing materials When using paint or lacquer to finish the mantel they must be heat resistant to prevent discoloration OPERATION The controls see Figure 6 are located behind hinged control panel door If using heater con trol panel door will be hot during and immedi ately after operation Open door by pressing on right side A spring magnet will push door forward Pull door down to open 1 Connect fireplace to power source Turn on lighted power switch see Figure 6 2 Adjust Flame Ember Backlight Heater to desired settings using the control pad on fireplace Figure 6 or remote control Figure 7 page 8 Figure 8 page 8 shows fireplace settings available Default settings are circled Press control pad or remote control buttons once and release to adjust settings Note When on ember bed will lighten and darken automatically to simulate real embers 122638 01E The heater is pre set to the following temperatures HIGH will shut off when room reaches approximately 86 F 30 C MEDIUM will shut off when room reaches approximately 79 F 2
24. tenance can cause injury or property damage Refer tothis manual Forassistance or additional information consult a qualified installer AR CAUTION Donotexposethe heater to the elements such as rain etc Do not place clothing or other flammable material on or near firebox Never place any objects on the fireplace Carefully supervise young chil dren when they are in the room with fireplace Fireplace becomes very hot whenrunning Keep children and adults away from hot surfaces to avoid burns or clothing ignition Fireplace will remain hot for a time after shutdown Allow sur faces to cool before touching Do not install fireplace directly on carpet or similar surface which may restrictair circulation beneath unit When using electrical heaters basic precau tions should always be followed to reduce the risk of fire electric shock and injury to persons including the following 2 www fmiproducts com 1 Read all instructions before using this heater 2 Keep combustible materials such as furniture pillows bedding papers clothes and curtains at least 3 feet 0 9 m from front of heater 3 This heater is hot when in use To avoid burns do not let bare skin touch hot surfac es The grill directly in front of heater outlet becomes hot during heater operation 4 Extreme caution is necessary when any heater is used by or near children and whenever heater is left operati
25. y the au thority having jurisdiction New Construction or Renovation 1 Select a location at least 3 feet 0 9 m away from combustible materials such as curtains or drapes furniture bedding paper etc Mark desired location on floor and store unit in a safe dry and dust free location Frame in an opening leaving at least 1 4 6 mm around the edge of the unit see Framing Any new wiring must be done in compliance with local and national codes and other applicable regulations in order to reduce the risk of fire electric shock or other injuries Therefore it strongly recommended that you hire a professional to complete any such work Plan your power supply route See step 4 of Existing Fireplace Installation above Built In Fireplace 1 Remove front panel and front glass from fireplace see Cleaning and Maintenance page 8 Locate 3 prepunched clearance holes in each side of fireplace Press screws through brick liner then attach nailing flange brackets to each side of fireplace see Figure 4 Nailing Flange Bracket Figure 4 Attaching Nailing Flange Brackets Framing Figure 5 shows a typical framing of this heater using combustible materials All required clearances to combustibles must be adhered to Header height is measured from the base of the heater Header Height ee e Length Depth 4 0 75 0
Download Pdf Manuals